1. 04 30 2015 Version Page 51 Telemedicine Station Hardcase User Manual exp 27 04 2015 0 11 40 12 ae T j p Tur Video recording is in progress exp 27 04 2015 0 11 41 12 You can play pause or stop the recorded video Press on the Back button to continue your exams Page 52 04 30 2015 Version Telemedicine Station Hardcase M S User Manual dmb 1041 9015 TN 41 49 02 sae LL Q Start uration 00 00 12 Video ormat H264 Take picture Conference PRE RE ae r Start Start Oximeter ECG Start Start Temperature Glucose Edit Patient Information Recorded video information is displayed on the Home You can edit it by pressing on it 27104 2015 D 11 42 47 w 0 Revi w Delete Restart Back Then you can Review Restart or Delete the recorded video To erase this video press on the Delete button 04 30 2015 Version Page 53 Telemedicine Station Hardcase PARSYS User Manual 61 27 04 2015 1 11 46 53 2 This action will destroy all data of the running examination You will not be able to undo the operation Do you still want to continue Eee Start a f Press on the Yes button to confirm 04 30 2015 Version Page 54 Telemedicine Station Hardcase PARSYS User Manual 5 5 6 Using the Video Conferencing module Check that the Webcam power indicator turns 24 04 2015 D 17 42 53 Sta
2. Method Cancel Accept Select the blood pressure sensor using settings Then press on the Accept button Note This settings screen appears automatically with each new use of the NIBP module 04 30 2015 Version Page 30 Telemedicine Station Hardcase PARSYS User Manual 5 4 5 Pulse oximetry module setup SPO2 24 04 2015 1 17 53 33 Oo Automation M E mail Co fere ce Cloud a is Va Language y Press on the SPO2 button 24 04 2015 D 18 02 39 SPO2 average on 4 beats SPO2 average on 16 beats Pulse average on 8 seconds Pulse average on 16 seconds SPO2 average on 8 beats SPO2 average on 16 beats Pulse average on 8 seconds Pulse average on 8 seconds Cancel Accept Select the desired measurement method then press on the Accept button 04 30 2015 Version Page 31 Telemedicine Station Hardcase User Manual PARSYS 5 4 6 ECG module setup ECG 24 04 2015 1 17 53 33 Oo a oo Automation M E mail Cloud Language _ J ne gt Press on the ECG button 24 04 2015 1 18 03 04 Download ECG Data Last amp On Request Ignore Accept Select the desired ECG traces download mode then press on the Accept button 04 30 2015 Version Page 32 Telemedicine Station Hardcase PARSYS User Manual 5 4 7 Temperature module setup TEMP 24 04 2015 1 17 53 33 Gi Automation i gt ne 3 2 Q
3. So we recommend that you NEVER EXTRACT the Touchscreen Tablet PC out of its housing located inside the Telemedicine Station Hardcase NEVER DISCONNECT the cables connecting the Touchscreen Tablet PC see connections on the photo above NEVER TRY TO USE software differently from that described in this manual 04 30 2015 Version Page 11 2 3 Telecardia ECG Description 2 3 1 General features Telecardia represents a major advance in remote cardiac monitoring and portable medical equipment It enables health professionals to rapidly capture and send a patient s ECG under any circumstances without the constraints of a conventional device The trace captured is a digital simultaneous 12 lead 12 channel ECG in keeping with standard electrocardiographs usually used It can be sent automatically to a care watch center or be viewed on a PC next to the patient Telecardia has CE marking CE0459 This is an ECG device intended for temporary use class lla 2 3 2 Electrodes position Neutral Telecardia is an electrocardiograph simultaneous 12 lead 12 channel with fixed thoracic electrodes with dry electrodes no consumables 2 3 2 1 Precordial leads 2 Precordial leads The shape of the unit enables capture of the 6 precordial leads collected thanks to the 2 articulated arms These thoracic electrodes are dry and fixed from V1 to V6 The Neutral usually captured on the right leg is captured in the th
4. Take the arm cuff and check cable connection to the device Capture blood pressure Wrap the arm cuff around the subject s LEFT arm 04 30 2015 Version Page 44 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 Capture blood pressure Cc Press the appropriate button to make a capture 24 04 2015 D 18 14 22 The measurement progress appears 04 30 2015 Version Page 45 Telemedicine Station Hardcase gt User Manual exp 24 04 2015 D 17 42 53 Start Video Take picture Conference Start Oximeter Edit Patient Information Start Start Temperature Glucose Data are automatically displayed on the Home You can interact with it by pressing on exp 24 04 2015 D 18 16 22 Delete Restart Back You have the opportunity to Restart or Delete the measurement To remove it press on the Delete button 04 30 2015 Version Page 46 Telemedicine Station Hardcase PARSYS User Manual En 24 04 2015 D 18 17 13 This action will destroy all data of the running examination You will not be able to undo the operation Do you still want to continue ee Press on the Yes button to confirm 04 30 2015 Version Page 47 Telemedicine Station Hardcase User Manual PARSYS 5 5 4 Using the Photo module Check that the Webcam power indicator turns blue ty C EN LS 24 04 2015 D 17 42 53 O 5 Start
5. fe f l aA Lee Poesy Language Te Press on the TEMP button 24 04 2015 1 18 03 27 Default 375 o o Cancel Accept Select the temperature using settings then press on the Accept button 04 30 2015 Version Page 33 Telemedicine Station Hardcase PARSYS User Manual 5 4 8 Blood sugar module setup GLUCO 24 04 2015 1 17 53 33 ee i Automation Ah 3 2 Q fe f a Wee es Language a Press on the GLUCO button 24 04 2015 Q 18 04 04 mg dl mmol Cancel Accept Select the blood sugar using settings then press on the Accept button 04 30 2015 Version Page 34 Telemedicine Station Hardcase PARSYS User Manual 5 4 9 Automation setup Automation 24 04 2015 1 17 53 33 Language Te Press on the Automation button 24 04 2015 D 18 04 25 M Automatic Printing Automatic Conversion M JPG Format mn XML Format M Automatic Backup Copy files Move files mm O Ignore Accept Select the desired options then press on the Accept button 04 30 2015 Version Page 35 Telemedicine Station Hardcase User Manual PARSYS 5 4 10 E mail account setup E mail exp 24 04 2015 D 17 53 33 Language Press on the E mail button egy 24 04 2015 D 18 04 49 Profile SMTP_DEFAULT Port Account Identifier Password Confirmation Check or edit th
6. 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters whose maximum assigned transmission power is not given above the recommended separation distance d in meters m can be estimated by using the transmitter frequency applicable equation where P is the characteristic of the transmitter maximum transmission power in watts W according to its manufacturer NOTE 1 to 80MHz and to 800MHZ the higher d range frequency applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 04 30 2015 Version Page 87 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 9 Users Training It is imperative that the use of Telemedicine Station Hardcase be performed under the supervision of a medical doctor In all cases the user must have received prior training in the use of Station s equipment 04 30 2015 Version Page 88 Telemedicine Station Hardcase User Manual Ver 1 3 10 Maintenance 10 1 Telecardia ECG maintenance 10 1 1 Cleaning Disinfection The Telecardia machine can be cleaned and disinfected by wiping the electrodes in contact with the skin and the plastic unit except on the self adhesive label at the rear of the machine with cotton wool or a wipe soaked in a product such as STERANIOS or equivalent 2 glutaraldehyde solution Any other product would not ens
7. 43 Patient s examinations list Identification Name Dupont Forname Jeari o Glucose 0 72 afl SPO2 Pulse amp Dow 7 98 82 The Report appears You can view more precise exams by pressing on it 04 30 2015 Version Page 71 Telemedicine Station Hardcase PARSYS User Manual 5 7 4 Sharing a saved Report 24 04 2015 D 18 21 35 17 32 10 24 04 2015 17 30 25 From the data Reports history open a Report by pressing on it 24 04 2015 1 18 22 43 Patient s examinations list Identification Name Dupont Forname Jean D Temperature o EEA Jok Patient q l SPO2 Pulse Mog 82 Down 7 07 bpm Press on the Share button 04 30 2015 Version Page 72 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 Ein 24 04 2015 D 18 24 03 Patient s examinations list Identification Name Dupont cal Forname Jean Preview a 3 Print l EW i Export JPG E 4 Export XML f Cloud Q You have access to different printing and sharing features 7 k Setup gt Layout printing of the Report ie Preview gt Preview of the Report before printing f Print gt Printing the Report 3 Export JPG gt Export the Report to a JPEG image file Export XML gt Export the Report to an XML file Cloud gt Transmission of the Report to ParsysCloud Q E mail gt Emailing the Report c FTP gt Transmission of the Report t
8. User Manual Ver 1 3 1 Content Telemedicine Station Hardcase 1 1 Constituents Thank you for choosing PARSYS Telemedicine devices We hope it will bring you full satisfaction in your experience of telemedicine First please check the contents of your Telemedicine Station Hardcase Ref 300 010 It must contain the following elements 1 Telecardia ECG 1 Telecardia ambulatory electrocardiograph 1 vertical charger associated to Telecardia 1 peripheral patient cable with 3 banana plugs 3 colored limb clips red yellow and green 1 reset black cord for device reset 1 water spray 2 Biosys multi parameter device 1 oximeter cable with finger sensor SPO2 1 extension cable for blood pressure NIBP 1 adult size arm cuff NIBP 1 USB data transmission cord 1 power cord 3 Computer 1 Touchscreen Tablet PC 1 7 USB ports hub 4 Webcam 1USB HD webcam 5 Case 1 hard carrying case Hardcase equipped with 2P EU rear power cable and a RJ45 female socket 1 RJ45 RJ45 extension cable 6 Documentation 1 Warranty Certificate EN 1 User Manual Telemedicine Station HC TC EN 7 Options 1 glucometer 25 test strips 25 lancets 1 infrared thermometer 1M2M GPRS 3G modem 1 SIM card Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref Ref 29 001 29 064 23 029 36 007 8 11 23 051 36 0
9. area It is therefore imperative not to use these two devices simultaneously Use of another electro medical equipment connected to the patient There may be a risk if using another electro medical device together with Biosys on the same patient It is up to the user to get information in advance on possible risks related to the simultaneous use of such equipment and Biosys on the same patient A Using the oximetry sensor SPO2 on the patient lt is important that the patient be as quiet and motionless as possible to avoid any unwanted movement that could lead to the appearance of motion artifacts inducing a SpO value too low or a poor signal quality It is also important to take into account of a possible low peripheral circulation of the patient low perfusion which could result in the appearance of motion artifacts inducing a SpO value too low or a poor signal quality Materials in contact with the skin The device is designed and manufactured to avoid any risk posed by the materials in contact with the patients or the user The device is compliant with the materials biocompatibility directives The device s materials don t induce any toxicity effect or residual risks for children pregnant and nursing women 04 30 2015 Version Page 8 Telemedicine Station Hardcase User Manual 2 Equipment description 2 1 Overview 2 1 1 Description of the Station The Telemedicine Station Hardcase is designed to carry and
10. it is necessary to observe the behavior of the medical device to check that the operation is normal If abnormal performances are observed additional measures may be necessary such as reorienting or repositioning of the medical device on its operation site b In the frequency range of 150kHz to 80MHz it is appropriate that the field strengths are smaller than 3 V m 04 30 2015 Version Page 83 Telemedicine Station Hardcase User Manual PARSYS Recommended separation distances between portable and mobile RF communicating devices and the medical device The medical device is intended for use in an electromagnetic environment where radiated RF disturbances are controlled The customer or the user of the device can help to prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communicating device transmitter and the medical device as recommended below according to the maximum power emission of the communication device Teenie nies mun Separation distance according to the transmitter frequency m So LL output from 150kHz to 80MHz from 150kHz to 80MHZ from 150kHz to 80MHz d 1 2VP d 1 2VP d 2 3VP 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters whose maximum assigned transmission power is not given above the recommended separation distance d in meters m can be estimated by using t
11. transmit vital data as quickly as possible simple and easy to use medical sensors digital Bluetooth ECG tailor made case integrated power cables dedicated application integrated Touchscreen Tablet PC Electrocardiograph y Y v Y Pulse oximeter Y y 12 lead simultaneous 12 channel fixed thoracic electrodes no consumables 15 seconds single capture Bluetooth wireless transmission Lithium battery 60 trace autonomy SpO measurement short and long term heart rate indestructible and reusable finger sensor 04 30 2015 Version Y Y Y n a 10 Tablet PC Bluetooth wireless communication with T l cardia ECG centralization and transmission of vital data highly intuitive and upgradable software huge battery life Blood pressure automatic with arm cuff oscillometric method measures digital display adjustable for 1 or 3 successive captures Page 9 2 1 2 Power supply of the Station To ensure an effective energy management the Station features a power management system powered by a plug socket on its back The system is equipped with a rechargeable battery with a typical battery life of 8 00 hours to ensure a full and comfortable use of the different medical devices featured as standard into the Station Station s internal battery charging indicator Off Poor or no connection of the Station to 220V mains No charging is in progress Fixed RED The internal batt
12. z Device not protected against defibrillation shocks Device with internal electricity supply rechargeable lithium polymer batteries Battery life 50 peri critical ECG captures and Bluetooth transmission in one battery charge Automatic power off after transmission Internal protection using 500mA resettable fuse Type B class 2A machine diagnostic function Measurement with internal electrodes 9 simultaneous leads VR VL VF V1 V2 V3 V4 V5 V6 with reference to VN Reproduction of 12 leads D1 D2 D3 VR VL VF V1 V2 V3 V4 V5 V6 Input impedance 10 MQ Bandwidth 0 16Hz to 70Hz at 3db Adjustable to 30Hz by configuration Measurement linearity 0 01 Measurement sensitivity 2264 pt mV Sampling frequency 271 pts Backup of 6 peri critical 15 second ECGs rotating or fixed list backup management with saving maintained even without stack Saving of identification and configuration data in encrypted form Real time clock for ECG dating autonomy of 1 year from full charging level under normal storage conditions Displayed and or voice task procedure or action messages 2 line 16 character screen task procedure message display Operating mode setting computer configuration o maximum number of ECGs o voice prompt o rotating stack locking 04 30 2015 Version Page 78 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 o connection type Bluetooth type interface for
13. 06 25 041 23 020 23 063 23 056 23 080 23 083 29 092 36 038 36 026 34 006 23 073 37 003 37 034 25 201 25 202 25 082 If any items are missing do not hesitate to contact us at the address given in this User Manual see Section 12 04 30 2015 Version Page 5 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 1 2 List of symbols used A IX Warning consult attached documents Please read the notice No alarms system management gt BF type applied part lt K Do not dispose of in the bin but through the appropriate recycling channels Non ionizing radiation Device climatic range of use or storage S N Serial number M mm Medical device European compliance 04 30 2015 Version Page 6 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 1 3 Warnings PARSYS Telemedicine draws the attention of the user on the following points regarding 1 3 1 Telemedicine Station Hardcase Moving the Station lt is recommended to move the station with its cover upper position sealed to avoid contamination breakage or loss of its components A Using the devices while the station is connected to an AC 220V 50Hz There may be a risk of use electric shock when using devices on a patient while the Station is connected to an AC 220V 50Hz via the charging system It is strongly recommended not to use the Station devices while it is still connected
14. 30 2015 Version Page 27 Telemedicine Station Hardcase User Manual PARSYS 5 4 2 Video module setup Video 24 04 2015 1 17 53 33 454 gt c 3 a ct re 5 oF th 3 2 Q f l A EEn poce Language _ Press on the Video button 24 04 2015 1 18 00 04 Selected camera Logitech B910 HD Webcam Capture Format RGB 24 bpp Resolution 1280 x 720 Recording duration in seconds Unlimited time Limited time ES o S B CE Cancel Accept Select the camera its resolution and the video recording duration Then press on the Accept button 04 30 2015 Version Page 28 Telemedicine Station Hardcase User Manual PARSYS 5 4 3 Photo module setup Picture 24 04 2015 1 17 53 33 454 gt c 3 a ct re 5 F p 3 2 Q fe f l A See Poel Language a Press on the Picture button 24 04 2015 Q 18 00 44 Selected camera Logitech B910 HD Webcam Capture Format RGB 24 bpp Resolution 2048 x 1536 Cancel Accept Select the camera and its resolution then press on the Accept button 04 30 2015 Version Page 29 Telemedicine Station Hardcase PARSYS User Manual 5 4 4 Blood pressure module setup NIBP 24 04 2015 1 17 53 33 Automation M E mail Cloud kala 7 g 2 a DNS Pia eaa Press on the NIBP button 24 04 2015 1 18 02 10 i Adult Child
15. 84 w Conference i Start Oximeter Edit Start 00 Start Patient a Temperature Glucose Information 16 Batteries charge indicators display 04 30 2015 Version Page 22 Telemedicine Station Hardcase PARSYS User Manual 5 3 Entering Patient Data optional Entering Patient data is not compulsory in compiling the Patient record but IT IS HIGHLY RECOMMENDED Patient data is entered according to the following procedure Start Video Conference Start Oximeter Start Patient o Information temperature Press on the Edit Patient Information button 3 24 04 2015 D 17 43 31 Fornames Sex Not available Birthday Male Female Weight Height Press once to position the cursor at the desired point 04 30 2015 Version Page 23 PARSYS Name Forname Birthday Weight Height 178 Telemedicine Station Hardcase User Manual exp 24 04 2015 D 17 45 27 FilelD 1234567890 SSID 1994382482942 Sex amp Not available UGUO Male Female Input the data using the touch screen keyboard or an external keyboard if available Name Forname Birthday Weight Height exp 24 04 2015 D 17 45 27 FilelD 1234567890 SSID 1994382482942 Sex Not available EO Male Female To erase all the information already entered press on the Reset button To instantly validate the data entered press on t
16. CE directive relating to DEEE electronic and electric devices do not throw away in regular trash Please bring waste to specialized collection points 04 30 2015 Version Page 91 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 10 2 6 Checking the pressure static accuracy of the blood pressure arm cuff Air leakage measurement of the blood pressure arm cuff To check the static accuracy and the arm cuff air leakage pressure you should first made a test bench by following one of two possible schemes Medical Device Manometer Inflating device 2 Manometer N Medical Device When the test bench is made please follow the following procedure 1 From the main screen press the Settings button S 2 Press on the Calibration button iC 3 A dialog allows the operator to select the initial arm cuff pressure depending on the operation mode either Adult Neonatal or even manual This value can be adjusted within the following ranges Adult 140 180 mmHg Neonat 70 100 mmHg Manual 10 200 mmHg 04 30 2015 Version Page 92 Telemedicine Station Hardcase PARSYS User Manual Initial Inflation of Cuff 140 Cancel Accept Arm cuff initial pressure settings window 4 During the test a dialog displays in continuous the arm cuff pressure measure Cancel Arm cuff pressure measure test dialog 04 30 2015 Version Page 93 Telemedicine Station Hardcase PA
17. Hardcase PARSYS User Manual Ver 1 3 5 5 2 Using the oximetry sensor of Biosys Capture pulse oximetry Take the oximetry sensor and check cable connection to the device Capture pulse oximetry Put the subject s index finger inside the sensor 04 30 2015 Version Page 40 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 Capture pulse oximetry g Cc Press the appropriate 4 button to make a Fa capture 24 04 2015 CLEA Cancel The measurement progress appears 04 30 2015 Version Page 41 Telemedicine Station Hardcase User Manual PARSYS exp 24 04 2015 D 17 42 53 Start Video Take picture Conference Edit Patient Information Start Start Temperature Glucose Data are automatically displayed on the Home You can interact with it by pressing on exp 24 04 2015 D 18 11 47 W Delete Restart Back You have the opportunity to Restart or Delete the measurement To remove it press on the Delete button 04 30 2015 Version Page 42 Telemedicine Station Hardcase PARSYS User Manual Ein 24 04 2015 D 18 12 17 This action will destroy all data of the running examination You will not be able to undo the operation Do you still want to continue Press on the Yes button to confirm 04 30 2015 Version Page 43 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 5 5 3 Using the blood pressure arm cuff Biosys Capture blood pressure
18. PARSYS Telemedicine Head office 118 avenue de France 75013 Paris France Technical center 7 rue Niels Bohr 77400 Saint Thibault des Vignes France Tel 33 0 1 60 31 70 40 Fax 33 0 1 64 02 31 93 info parsys com User Manual Telemedicine Station HARDCASE 37 034 V1 3 Date of the first placing on the market of the product January 2014 C o459 P S TELEMEDECINE 04 30 2015 Version 1 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 SUMMARY CONTENT TELEMEDICINE STATION HARDCASE ssccceeeeeessceeenneeeeeseeceesnseeeeeseecoeeeseeeeenseeaes 5 LL CON TTOENI sso de E E E te 5 te TIS TOR YUBO D E E N T E E EE 6 To WARNING ara a E E EE EEE A E E 7 1 3 1 Telemedicine Station Hardcase 7 Pe TECCO e A esta tea ait inattendue 7 BS DO YS e TR 8 EQUIPMENT DESCRIPTION uen 9 CON EN EN a Sa eo en ea a ts 9 211 TIC SCINIUOM or Ne SOON apse acts socio cee ce slog eae EE gece EE EEEE 9 2 1 2 Power supply OF the Station sicczseccecnssceenconteceteesSiewscesteestecex8oxeidenecendes dec ent esse dresse eases 10 2 2 DESCRIPTION OF THE TOUCHSCREEN TABLET PG iscsssdicnsshreasiessertansataniawetiqciansatasaspenieriandstavinerddueinnestamans 11 221 _COON TATI OURES en ee enn nen er N E EE E ee eee 11 US SO OS eee EEE oe emer eee 11 2 3 TELECARDIA ES GSC AIP TION sn cctasanencdiceiancomenlannusndiunizeuenaseisice eomiake
19. R S statement electromagnetic IMMUNITY For all DEVICES and EM SYSTEMS Directives and manufacturer s statement electromagnetic immunity The device is made to be used in the electromagnetic environment specified below The client or user of the device must ensure that the device is used in such environment Immunity trials Trial level Conformity Electromagnetic environment CEI 60601 level directives Electrostatic shocks ES 6 kV in contact Conforms Floors must be made of wood concrete or 8 kV in the air ceramics lf the floors are topped with CEI 61000 4 2 synthetic materials it is important that the relative humidity remains at 30 at least Magnetic field at the rate of Conforms Magnetic fields at the rate of the electric the electric network 50 60 network must have the distinctive levels of a Hz representative place located in a commercial or hospital environment CEI 61000 4 8 04 30 2015 Version Page 85 Telemedicine Station Hardcase PARSYS User Manual Table 3 Directives and MANUFACTURER S statement electromagnetic IMMUNITY For all DEVICES and EM SYSTEMS Directives and manufacturer s statement electromagnetic emissions The device is made to be used in the electromagnetic environment specified below The client or user of the device must ensure that the device is used in such environment Trial level Conformity oo CEI 60601 level Electromagnetic environment dire
20. RSYS User Manual Ver 1 3 11 Malfunctions 11 1 Telecardia ECG 11 1 1 The Telecardia ECG does not send any trace After capturing the ECG no trace is received by the Touchscreen Tablet PC the Bluetooth connection is most certainly lost We therefore advise you A N NEVER ATTEMPT any direct manipulation on the Touchscreen Tablet PC Contact the PARSYS Telemedicine After Sales Service 11 1 2 The ECG is subject to interference Check that the capture protocol described in section 5 3 has been followed in particular that the correct color code has been followed for the limb clips red on the right arm yellow on the left arm and green on the left leg that the electrodes and the skin have been humidified using the spray The patient and operator must be as relaxed as possible in order to avoid any tense movements when capturing the ECG 11 1 3 The Telecardia ECG is not charging Check that the protocol described in section 2 3 5 has been followed in particular that the Telecardia is in the correct position on the charger that the red LED on the charger is on during charging that the Telemedicine Station Hardcase is correctly plugged into the mains Should you note a low battery level after 1 hour s charging please contact the PARSYS Telemedicine After sales Service 04 30 2015 Version Page 94 11 1 4 The Telecardia ECG remains blocked If when using the device it blocks for more than 1 min U
21. User Manual Ver 1 3 5 5 7 Using the Telecardia ECG 04 30 2015 Version Capture ECG NB For the sake of clarity the illustrations show a figure with no shirt However the subject does not have to take his her shirt off SHIRT OPEN SLEEVES UP is satisfactory The ECG can be captured with the subject SITTIN or LYING DOWN NEVER STANDING UP Capture ECG Connect the ECG cables to the limb clips following the colour codes Dampen the limb clips with the water spray Page 58 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 Capture ECG Slip the limb clips over the subjects arms Follow the colour codes A RED for the RIGHT ARM YELLOW for the LEFT ARM for the RIGHT arm for the LEFT arm Capture ECG Slip the limb clip over the LEFT leg 04 30 2015 Version Page 59 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 Capture ECG Press briefly on the button to open the ECG arms NEVER use FORCE to open the arms Capture ECG Connect the ECG limb clips cable in the socket on the LEFT side of the unit Gently turn the cable s RED mark pointing UP 04 30 2015 Version Page 60 els ee fers PARSYS User Manual Ver 1 3 Capture ECG Dampen the subject s chest with the water spray Capture ECG Place the ECG unit on the subject s chest The BLACK ARROW of the left arm aligned in the middle of the sternum The ECG unit s button should be le
22. cardia ECG is fully charged in approximately 2 5 hours from a 220V 50Hz source via the woundable plug at the back of the Station IMPORTANT DO NOT ATTEMPT TO REMOVE THE VERTICAL CHARGING BASE FROM ITS HOUSING SO AS NOT TO AFFECT CHARGING OF THE TELECARDIA 04 30 2015 Version Page 14 6 Inserting of Telecardia in its vertical charger An indicator called the CHARGING INDICATOR is located on the charger and indicates the device s level of charge and that the device is effectively in contact with the charger the CHARGING INDICATOR does not light up when Telecardia is not correctly inserted in its slot without contact with the charging contacts or missing from the slot the CHARGING INDICATOR remains RED as long as Telecardia is charging the CHARGING INDICATOR is GREEN when Telecardia is charged 2 3 5 Viewing the trace on the Touchscreen Tablet PC Following capture the data is sent to the Touchscreen Tablet PC automatically via the Bluetooth radio link which has a free field range of approximately 100 open meters The software installed on the Touchscreen Tablet PC makes it possible to display the captured ECGs send the ECGs by e mail file and consult previously captured ECGs 04 30 2015 Version Page 15 Telemedicine Station Hardcase User Manual Ver 1 3 2 4 Biosys Description 2 4 1 Overview of Biosys Biosys is a wired battery operated multi parameter device to be applied on a patient in orde
23. computer link and transmission base link o Bluetooth version 2 0 EDR o Class 1 100 mW m Average transmission speed 115 2 Kb s depends on medium used Operating conditions o Temperature 10 C to 35 C o Relative humidity level 30 to 75 o Atmospheric pressure 700 mb to 1060 mb Storage and transport conditions o Temperature 10 C to 50 C o Relative humidity level 10 to 85 o Atmospheric pressure 500 mb to 1060 mb 7 3 4 Functional features Front panel m start up button configuration button under bushing cover blue green LED indicating o steady green machine power on o steady blue Bluetooth transmission to PC or base 1 LCD 2 x 16 character line screen without backlighting Curved lower section 3 chromium plated brass convex round electrodes Upper section Hatch opening outwards and used to support the unit Upper section under hatch m 10 x 4 mm female cylindrical connectors with attachment collar between the two bodies 1 signal transfer control button to electrocardiograph analogue output or configuration Rear panel back m Instruction label 2 Charging contacts Edges 1 folding articulated arm on either side supporting electrodes V1 V2 and V5 V6 Under the right arm 1 connecting socket for VR VL and VF limb clips cable 04 30 2015 Version Page 79 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 7 4 Biosys 7 4 1 General featu
24. ctives The portable and mobile RF communicating devices should be not used nearer of any part of the medical devices including cables than the recommended separation distance calculated from the transmitter frequency applicable equation Recommended separation distance d 1 2VP RF conducted disturbances 3 Veff CEI 61000 4 6 from 150kKHz to 80MHz d 1 2VP from 80MHz to 800MHz d 2 3VP from 800MHz to 2 5GHz RF radiated disturbances 3 V m where P is the maximum output power of the transmitter in CEI 61000 4 3 from 80 to 2 5GHz watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m of separation It should that field strengths from fixed RF transmitters as determined by an electromagnetic survey on site should be less than the compliance level in each frequency range b Interferences may occur in the vicinity of equipment marked with the following symbol e 2 NOTE 1 to 80MHz and to 800MHZ the higher d range frequency applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM FM radio and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due t
25. dicator of Biosys does not light up this indicates a malfunction See Malfunctions 11 2 4 04 30 2015 Version Page 17 Telemedicine Station Hardcase User Manual 2 5 Webcam Description Wired USB webcam contained in Telemedicine Station Hardcase is a Logitech Pro C920 Carl Zeiss Optics 720p with CE mark To use it it is not necessary to connect it Indeed the webcam is continuously connected to the Touchscreen Tablet PC 13 Connection of the Webcam to the Touchscreen Tablet PC 04 30 2015 Version Page 18 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 3 Bluetooth connection installation Devices comprising in the Telemedicine Station Hardcase have been set in order to communicate directly with the Touchscreen Tablet PC by Bluetooth mode No installation of Bluetooth connection is necessary In case of malfunction of the Bluetooth connection we recommend that you NEVER attempt to change the settings by yourself ALWAYS contact the After Sales Service of PARSYS Telemedicine or its duly appointed distributor 04 30 2015 Version Page 19 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 4 PC software installation The Telemedicine Station Hardcase comes with a Touchscreen Tablet PC that is fully configured and operational No software installation is required In case of software malfunction we recommend that you NEVER attempt to reins
26. e application email account then press on the Back button to confirm the information 04 30 2015 Version Page 36 Telemedicine Station Hardcase PARSYS User Manual 5 4 11 ParsysCloud access setup Cloud exp 24 04 2015 D 17 53 33 Automation Press on the Cloud button exp 24 04 2015 D 18 05 22 Profile MK_DEFAULT Authentication hitps samui0 parsys com apivO authy Examinations https samu10 parsys com api v0 exams Account Identifier Password Password Confirmation Check or edit the access information to ParsysCloud then press on the Back button to confirm the information 04 30 2015 Version Page 37 Telemedicine Station Hardcase PS User Manual 5 4 12 Language selection Language 24 04 2015 1 17 53 33 Automation Press on the Language bution 24 04 2015 D 18 05 42 Select the desired available language by pressing on the corresponding button 04 30 2015 Version Page 38 Telemedicine Station Hardcase User Manual PARSYS 5 5 Taking measurements 5 5 1 Using the application s tutorials Eag 24 04 2015 D 17 42 53 Start R d Video nf Take picture Conference Video Start Oximeter Edit Patient Information Start Start Temperature Glucose Press on the Help button 24 04 2015 D 18 08 54 Press on the desired sensor button to display its using tutorial 04 30 2015 Version Page 39 Telemedicine Station
27. ery of the Station is below 5 Flashing ORANGE The internal battery of the Station is below 20 Flashing GREEN The internal battery of the Station is charging Only when the Station is connected to the mains Fixed GREEN The internal battery of the Station is charged more than 90 Only when the Station is connected to the mains If the Station charging indicator doesn t light despite of its good connection to the mains we recommend that you NEVER attempt to repair the Station by yourself ALWAYS contact the after sales service of PARSYS Telemedicine or its duly appointed distributor 04 30 2015 Version Page 10 2 2 Description of the Touchscreen Tablet PC 2 2 1 General features The Touchscreen Tablet PC included in the Telemedicine Station Hardcase is an ASUS Transformer Book T100 It features a Microsoft Windows 8 1 32 bits operating system It has an LED 16 9 10 1 inches touchscreen Its resolution is 1366 x 768 pixels Its processor is an Intel Atom Z3740 Quad Core 1 33 GHz 1 86 GHz Turbo The tablet has 2 GB of memory and a hard disk SSD 32GB For communications the tablet uses Bluetooth 4 0 and WiFi N technologies Plug ins 1 Touchscreen Tablet PC 2 2 2 Use instructions For an optimal use of the Station the Touchscreen Tablet PC should under no circumstances be used as a personal computer but only as a dedicated terminal for viewing and transmitting vital data
28. esaueticciauietasuseieriandeissinercsaeinnestiamane 12 Vag Hl COOP ES E T A EEE OE E ENE TEE 12 La BE OGS POSO eoe e EE E Serres ee ees 12 Be DPVCECONTOLDUNONS osii en e E E oaths canoes saat Geecsenmecneneaseactscanoeaee 14 Bee FOWO SUDD V oen E E E lai dei ie 14 2 3 5 Viewing the trace on the Touchscreen Tablet PC 15 2 4 BIOSYS DE CP TON edo vance etic eatsseadtgecmiecutecesaqeadeeetuastaueneteceeedsee 16 Zest COW CLUI OW ON OG cares iss no es de one ee tt 16 24r VOC SISOS dde scree ee EE AE ctache 16 2 4 3 Power socket and indicators inner 17 2 NN ECM DESCRIPTION a eo 18 BLUETOOTH CONNECTION INSTALLATION c ssccccesssceeesssceesesseceesenseceesenseceeeenssceesenseneeesneaes 19 PC SOFTWARE INSTALLATIONS AEE 20 SEQUENCES OF USE MAKING A REPORT cccccccccsssseeeeeeeeeeeeeensneeeeeeeeeoeesseseeeeseeooeesseseeeessaoes 21 5 1 TOUCHSCREEN TABLET PC ON STANDBY OFF ccccccccececeeeseeeeeeeeeeeaeeeceeeeeeeeeesaaaseeeeeeeeeeaaaaees 21 D FO GE een E tee 0e 22 5 3 ENTERING PATIENT DATA OPTIONAL 5e ciessencennssentetesenonens caneet spaced les memtetes css 23 5 4 APPLICATION CONFIGURATION AND SETTINGS 0 ssccccccccceesssseceececcceeusseeececeeseeeaueeeeeesesseaaaseeeeeeesseeaaaaess 26 5 4 1 Video Conferencing module setup Conf 27 5 4 2 Video module setup Video ien icnivedecssocctcecmivessdactnteceswbccpaendazndernbncnrdensatouasebrenreecbeabsesbaveeudenteates 28 543 PHO Module setup FICUFE
29. ettings Delete Depending on the installed configuration screens such as the one above may appear to ask you the necessary information to send the Report via the selected mode Cloud Email or FTP Once information is entered press on the Send button to confirm the transmission Note This information can be automated by entering it permanently in the corresponding settings see section 5 4 Exp 24 04 2015 D 18 29 18 To remove all the exams without saving press on the Delete button 04 30 2015 Version Page 68 Telemedicine Station Hardcase PARSYS User Manual Eag 24 04 2015 D 18 29 49 This action will delete the examination s file You will not be able to undo the operation Do you still want to continue Press on the Yes button to confirm 04 30 2015 Version Page 69 Telemedicine Station Hardcase PARSYS User Manual 5 7 3 Consulting the reports history 24 04 2015 17 42 53 Q Start LU Video Take picture lize Conference Start Start Oximeter ECG Start Start Temperature Glucose Edit Patient Information Press on the History button 24 04 2015 D 18 21 35 17 32 10 Dupont 24 04 2015 17 30 25 Previous finalized exams Reports appear Press on a report to view it You can also scroll through the Up and Down buitons 04 30 2015 Version Page 70 Telemedicine Station Hardcase M gt User Manual exp 24 04 2015 D 18 22
30. he Back button 04 30 2015 Version Page 24 Telemedicine Station Hardcase User Manual PARSYS exp 24 04 2015 D 17 45 57 Start Oximeter Patient information are displayed on the Home You can edit or erase it by pressing on it 04 30 2015 Version Page 25 Telemedicine Station Hardcase User Manual PARSYS 5 4 Application configuration and settings Before using a medical device you must prepare the application to receive and read the data by following 24 04 2015 D 17 42 53 Start Video Take picture Conference Start Oximeter Edit Patient Information Start Start Temperature Glucose Press on the Settings button 24 04 2015 17 53 33 anneal a amp E mail 4 fer a Ce en L Cloud a cy Language iib Select the item to set then follow the next sections 04 30 2015 Version Page 26 Telemedicine Station Hardcase User Manual PARSYS 5 4 1 Video Conferencing module setup Conf exp 24 04 2015 D 17 53 33 ee C Language gt P Tite gt i ace oi ct re 5 m 3 D Lee CCE Press on the Conf button exp 24 04 2015 D 17 50 36 ParsysRTC server s URL u10 parsys com station login station parsys com amp peer mydoctor parsys com Cancel Accept Check or edit the URL access to ParsysRTC server Video Conferencing then press on the Accept button 04
31. he transmitter frequency applicable equation where P is the characteristic of the transmitter maximum transmission power in watts W according to its manufacturer NOTE 1 to 80MHz and to 800MHZ the higher d range frequency applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 04 30 2015 Version Page 84 Telemedicine Station Hardcase User Manual PARSYS 8 2 Biosys Table 1 Directives and MANUFACTURER S statement ELECTROMAGNETIC EMISSIONS For all DEVICES and EM SYSTEMS Directives and manufacturer s statement electromagnetic emissions The device is made to be used in the electromagnetic environment specified below The client or user of the device must ensure that the device is used in such environment Emin tite Conformity Electromagnetic environment directives The device uses RF energy only through his internal RF Emissions Gronn 3 functions As a consequence its RF emissions are CISPR 11 p very weak and are not likely to cause interferences in a nearby electronic device RF Emissions Class B CISPR 11 a The charging power box catalogue product must Harmonic Emissions Non applicable solely be used with the device in sleep mode CEI 61000 3 2 disconnected from the patient Pulse fluctuations Ne 2 Flicker CEI 61000 3 3 pP Table 2 Directives and MANUFACTURE
32. ic environment specified below The client or user of the device must ensure that the device is used in such environment Immunity trials Trial level Conformity Electromagnetic environment CEI 60601 level directives Electrostatic shocks ES 6 kV in contact Conforms Floors must be made of wood concrete or 8 kV in the air ceramics lf the floors are topped with CEI 61000 4 2 synthetic materials it is important that the relative humidity remains at 30 at least Magnetic field at the rate of Conforms Magnetic fields at the rate of the electric the electric network 50 60 network must have the distinctive levels of a Hz representative place located in a commercial or hospital environment CEI 61000 4 8 04 30 2015 Version Page 82 Telemedicine Station Hardcase User Manual PARSYS Table 3 Directives and MANUFACTURER S statement electromagnetic IMMUNITY For all DEVICES and EM SYSTEMS Directives and manufacturer s statement electromagnetic emissions The device is made to be used in the electromagnetic environment specified below The client or user of the device must ensure that the device is used in such environment Trial level Conformity CEI 60601 level Electromagnetic environment directives The portable and mobile RF communicating devices should be not used nearer of any part of the medical devices including cables than the recommended separation distance calculated from the t
33. iers specific to this network connection and validate the connection The Touchscreen Tablet PC then uses this connection priority In addition it is possible to save the settings of the WiFi network used to not having to make this setting for each connection v GPRS 3G optional The Station could be equipped with an optional GPRS or 3G module to access the Internet wirelessly when a GPRS 3G network is available Y Y Y Y Y The different connection levels to the GPRS 3G network 04 30 2015 Version Page 66 Telemedicine Station Hardcase PARSYS User Manual 5 7 2 Finalizing exams exp 24 04 2015 0 18 28 43 WUIL i Start Video Record Finalize Conference Video Name Smith B Forname John Sex M Press on the Finalize button to validate the exams Eag 24 04 2015 D 18 29 18 Press on the Save button to locally save the Report into the tablet PC Or depending on configuration Press on the Cloud button to locally save the Report and send it to ParsysCloud Press on the E mail button to locally save the Report and send it by email Press on the FTP button to locally save the Report and send it to an FTP server 04 30 2015 Version Page 67 Telemedicine Station Hardcase User Manual PARSYS 24 04 2015 Q 18 30 24 Copy Subject ECG capture s sent on 2015 04 24 18 30 21 Attached Files Message 01 Smith John 2015 0424 183017 STX Smith John 2015 0424 183017 STX S
34. ion WLAN Standard USB 3 0 ports Wireless mode Processor speed Internal memory Processor model ASUS Transformer Book T100TA DKOO2H Intel Atom Z3740 Windows 8 1 32 bits 802 1 1a b g n j Yes Yes Bluetooth 4 0 class 1 Integrated Intel HD Graphics LED Touchscreen 10 1 inches 1366 x 768 pixels 1 33 GHz 1 86 GHz Turbo 2GB Intel Atom Z3740 32 0 GB ASUS 5V 10W AC DC Adapter Lithium Polymer Battery 11 0 hours 263 x 171 x 10 5 mm 0 523 Kg Page 77 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 7 3 Telecardia ECG 7 3 1 General features Portable event driven 12 lead temporary electrocardiograph Radio data transmission Bluetooth Lithium polymer rechargeable battery power supply 7 3 2 Mechanical features Material two half body unit one hinged hatch made of flame retardant ABS 7 Color RAL 9002 white with marking Surface condition 26 arbours Electrode on unit o chest on lower section gt VN V1 V2 V3 V4 V5 V6 7 10u chromium plated brass m Electrodes with cable o VR VL and VF peripheral limb clips cable Connectors o female cylinder connectors with collar under bushing cover for electrocardiograph connection analogue trace output m Protection index IP20 m Folded overall dimensions 210 mm x 100 mm x 50 mm m Weight lt 550g 7 3 3 Electrical specifications a Device intended for temporary use
35. measurement of the blood pressure arm cuff 92 11 MALFUNCTIONS a a 94 ti FEE CARDA EC Gi ea es 94 11 1 1 The Telecardia ECG does not send any trace 94 11 1 2 The ECG is subject to interference 4 94 11 1 3 The Telecardia ECG is not charging 94 11 1 4 The Telecardia ECG remains blocked 95 11 1 5 The Telecardia ECG has lost is time stamping 95 RO e ee A EE EE E E E E 96 11 2 1 Software troubleshooting screen lock Windows display 96 11 2 2 The device is no longer recognized after launching the software ccccssseeeeeeeeeneeeeeesenneees 96 11 2 3 The unit does not respond to commands from the software ccccssseccceecsseeeeeeeeseeeeseessaaeens 96 11 2 4 Connection and charging LED indicators dont turn on 96 04 30 2015 Version Page 3 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 11 2 5 Malfunctions related to wired Sensors 2 1ccccccececececececesaesenscecaenenensceeaenensnscaeaenensteeaenensnscaenens 97 11 3 REMOTE CONTROL cccceccececcececcececcecaccecucuccucuececneuecuunecuuaecueaucucuenecsesecuunecsuaecsuaeceeesacausecseuecsuaecsuaeceuaeeas 98 12 PARSYS TELEMEDICINE WARRANTY AND AFTER SALES SERVICE c ccccscescscescecescecesceenss 100 Page 4 04 30 2015 Version Telemedicine Station Hardcase PARSYS
36. meter _ ore Q Press on the Support button 04 30 2015 Version Page 98 Telemedicine Station Hardcase PARSYS User Manual 24 04 2015 D 18 09 43 This action will allow our technician to remotely take control of this device Do you still want to proceed si Confirm the remote control by pressing on the Yes button 28 04 2015 D 15 34 21 sart i Record Video s Take picture Conference PARSYS T l m deci PARSYS Autoriser contr le a distance Fe Veuillez communiquer le n ID et le mot de passe au Technicien PARSYS pour qu il puisse f Pr t se connecter connexion s curis e www teamviewer com Annuler Edit Patient Information Start Start Temperature Glucose 15 34 a PRES 28 04 201 A Teamviewer window appears The technician needs you to give him the displayed ID number of your equipment to open the access 04 30 2015 Version Page 99 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 12 PARSYS Telemedicine Warranty and After Sales Service The Customer agrees to comply with the Warranty Conditions listed on the Warranty Certificate accompanying the Equipment The Equipment is supplied with a one year 1 warranty during which period the Customer will be able to exchange Equipment found to have a latent defect and subject to the Customer having informed PARSYS Telemedicine thereof in writing and in detail In the event of a functional faul
37. nee E LENE EEREN EEEE EEEE EERE RAS 29 5 4 4 Blood pressure module setup NIBP ns 30 5 4 5 Pulse oximetry module setup SPOQ ccccccssseeseccsssneeeecccnauseecsssaucecesssaueseeesssaeeseeessaaaesseessaaanss 31 BA ECG Module SO DECO E R E EEE 32 5 4 7 Temperature module setup TEMP ccccccccsseeecccccsnseeecesnauseecssaaeeeeeesssauenecesssaueseeesssaaeeeesssaaaass 33 5 4 8 Blood sugar module setup GLUCO ner 34 5 4 9 Automation setup Automation ccccccsseeecccsseeecsaeeeeecaaueeeesaueeessausneesaaeneessaaeeessaaaeessaaeeesssaeeeneas 35 5 4 10 E mail account setup E mail ccccccsseccccnseuseccscnseccnseusecnsesesensusesensausecasansesensauesensansesanssesenss 36 5 4 11 ParsysCloud access setup Cloud 37 5 4 12 Language selection Language ss 38 55 TAKNG MEASUREMENTS ee en de ia 39 5 5 1 Using the application s tutorials cccccsseecccccssseeeecesnsneeeecesaauueecsssaueseeessasaeneesessaaeneeesssaaeeeessssaaass 39 5 5 2 Using the oximetry sensor Of Biosys 40 5 5 3 Using the blood pressure arm cuff BIOSYS sccccccccssseeeeccenseeeeecssaaeesecesssaueneceessaaeeseesssaeneeeessaaaess 44 5 5 4 Using the Photo module rer 48 5 5 5 Using the Video module 51 5 5 6 Using the Video Conferencing module ss 55 2357 DSi the Telecardia EGU mene ee ee ae ene ee ee ee 58 04 30 2015 Version Page 2 Telemedicine Station Hardca
38. nlarge or shrink the trace s image 04 30 2015 Version Page 64 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 5 6 2 Special settings ion The Settings button is used to choose display formats and trace s measures Strips V Report H Report Grid Measures Calipers Strips Leads are displays in strips mode classified vertically V Report Vertical printing format portrait mode H Report gt Horizontal printing format landscape mode Measures Display or non display of ECG measures Grid Display or non display of the background s grid Calipers Display or non display of the calipers 04 30 2015 Version Page 65 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 5 Finalizing and sending a Report Once the examination is finished and Patient information possibly entered you can validate the exams by finalizing the Report Please first ensure proper operation of the communication system used 5 7 1 Transmission systems v Ethernet RJ45 Plug the RJ45 extension cable to the RJ45 connecting socket at the back of the Telemedicine Station Hardcase which is connected to the Touchscreen Tablet PC The connection is automatically done in Plug and Play mode v WiFi The Touchscreen Tablet PC also has a WiFi feature enabled by default To establish a connection with a wireless WiFi network simply set identif
39. ntact you and tell you how to perform the update procedure to contact the PARSYS Telemedicine After Sales Service or appointed distributor We therefore advise you NEVER ATTEMPT to configure it yourself 04 30 2015 Version Page 75 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 7 Products technical features 7 1 General features of the Station Type Dimensions Weight Materials Protection Connectivity Operation Power supply Medical supply model Battery life Using temperature Recharging temperature Transportation and Storage temperature Using relative humidity Recharging relative humidity Transportation and Storage relative humidity 04 30 2015 Version Hardcase Pelicase 1450 420 x 331 x 174mm 7 Kg ABS Polypropylene Polymer IP66 1 2P male sector 1 RJ45 Ethernet socket On rechargeable batteries Input 110 240V 50 60 Hz 1 1A Output 12V DC 3 8A max current consumption FRIWO Desktop Power Supply Ref FW7405M 12 Class Il certified EN 60601 1 Typically 8 00 hours 10 35 C 10 35 C 10 50 C 30 to 85 30 to 85 30 to 85 Page 76 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 7 2 Touchscreen Tablet PC Model OS Mini HDMI Network Bluetooth Graphics Display type Screen size Resolution Capacity Manufacturer Power Battery Battery life Dimensions Weight 04 30 2015 Vers
40. o an FTP server 04 30 2015 Version Page 73 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 5 8 Switching off the Touchscreen Tablet PC and closing the Station software 24 04 2015 D 17 42 53 Start Oximeter Once the examinations are finished and have been sent do not forget to switch the Touchscreen Tablet PC off by pressing Quit button recommended then Confirm or by a long pressing of the On Off button based in the bottom right of the screen as presented in 5 1 until the Touchscreen Tablet PC comes to a complete stop For optimal use of the Telemedicine Station Hardcase once the examinations have been completed and sent you must ensure that all equipment is stored away We therefore advise you to make sure that each device is put away in the correct slot to store the Telecardia Patient cable the blood pressure flexible tube and oximeter sensor properly making sure that they are correctly inserted in the specific slot to check that Telecardia is correctly inserted in its vertical charger to check that the Touchscreen Tablet PC connections are correct 04 30 2015 Version Page 74 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 6 Software upgrade initialisation The Telemedicine Station Hardcase comes with a configured and operational Touchscreen Tablet PC Any software updates are carried out during maintenance operations PARSYS Telemedicine will co
41. o fixed RF transmitters it should be considered to proceed to an electromagnetic survey on site If the measured field strength in the location where the medical device is used exceeds the applicable RF compliance level above it is necessary to observe the behavior of the medical device to check that the operation is normal If abnormal performances are observed additional measures may be necessary such as reorienting or repositioning of the medical device on its operation site b In the frequency range of 150kHz to 80MHz it is appropriate that the field strengths are smaller than 3 V m 04 30 2015 Version Page 86 Telemedicine Station Hardcase User Manual PARSYS Recommended separation distances between portable and mobile RF communicating devices and the medical device The medical device is intended for use in an electromagnetic environment where radiated RF disturbances are controlled The customer or the user of the device can help to prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communicating device transmitter and the medical device as recommended below according to the maximum power emission of the communication device Teenie nies mun Separation distance according to the transmitter frequency m So LL output from 150kHz to 80MHz from 150kHz to 80MHZ from 150kHz to 80MHz d 1 2VP d 1 2VP d 2 3VP 0 01 0 12 0 12 0 23 0 1 0 38
42. oe Pee eee ene re ee 80 Tee OUI CY Or OZ rants a ee ce ee te ie on tn dei 80 TS Blood pressure NP Le ee ec 80 D UBNT POAN eena e E a a oe castnente aus asa deca sna ciens aesinsenceonceacee 81 8 ELECTROMAGNETIC EMISSIONS ccccccccssssesssseeeeeeeeccnnesseeeeeeeecconasseeeeeeeeoooanseeesseeeeoonsnseeeees 82 TEI asta ee doe agaee 82 o2 BO V eae eos cern estore wat pee ets aaa ne pee seas nee pec eta E E EE nee een E EAE 85 9 USERS ER INI gars tac ce este een 88 10 MAINTENANCE aa en a ane Oai 89 10 1 TELECARDIA ECG MAINTENANCE ae den re a mi hou 89 10 1 1 CICARING 7 DISINI CIONE Re eau date de ie td elodie 89 10 1 2 Procedure in the event that the device is dropped or fallS ccccccseeccccseesececeeeeceeseeseeeseneeeeees 89 10 1 3 Feco OO cea bacceceanerae 89 10 1 4 ME TOIOOICAl 6 61210 S osere rene i E E E E EO 90 10 1 5 BEEE CO GUC AN N AE O E TE A T T 90 10 1 6 Product scrap realment issssihoustsatasers nhio dns dan A nE INES EET EE AEE EEA RE n 90 TO BOSSY MANTEN NOE oar nep EN E E AEAEE E ERN 91 10 2 1 Cleaning DISIMOCNIOME SR de EEE EEEE 91 10 2 2 Procedure in the event that the device is dropped or fallS ccccccseeccccsseseccseeeeeeeeeeecensneeeeeeas 91 10 2 3 Pe OCCO O arr EA A E E E E 91 10 2 4 M TODO CAOCRS D ne da binen 0 dede EEPE E ANE E EREE OE E 91 10 2 5 Product scrap treatment en abonnement aan de en ai 91 10 2 6 Checking the pressure static accuracy of the blood pressure arm cuff Air leakage
43. oftware Software updates are performed during maintenance operations For each update PARSYS Telemedicine contacts you and tells you how to update We recommend that you NEVER ATTEMPT an update by yourself Contact the customer service of PARSYS Telemedicine or its distributor 11 2 2 The device is no longer recognized after launching the software lf after checking the correct connection of the Biosys to the Touchscreen Tablet PC and launching the appropriate software the device still does not respond please contact the customer service of PARSYS Telemedicine and do not try to modify it by yourself We recommend that you A N NEVER ATTEMPT an update by yourself Contact the customer service of PARSYS Telemedicine or its distributor 11 2 3 The unit does not respond to commands from the software Check the correct connection of the Biosys to the Touchscreen Tablet PC If the device does not respond please complete the reset procedure presented in 10 2 3 then quit and restart the application on the Touchscreen Tablet PC If Biosys still does not respond please contact the customer service of PARSYS Telemedicine or its distributor and do not try to change it yourself We recommend that you A N NEVER ATTEMPT a modification by yourself Contact the customer service of PARSYS Telemedicine or its distributor 11 2 4 Connection and charging LED indicators don t turn on Check the correct connection of Bi
44. on Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 Logitech 960 000767 Logitech HD Pro C920 Carl Zeiss 0 227 Kg Wired USB 2 0 Black Full HD 1080p Built in Page 81 Telemedicine Station Hardcase User Manual PARSYS 8 Electromagnetic emissions 8 1 Telecardia Table 1 Directives and MANUFACTURER S statement ELECTROMAGNETIC EMISSIONS For all DEVICES and EM SYSTEMS Directives and manufacturer s statement electromagnetic emissions The device is made to be used in the electromagnetic environment specified below The client or user of the device must ensure that the device is used in such environment Emin tite Conformity Electromagnetic environment directives The device uses RF energy only through his internal RF Emissions Group 1 functions As a consequence its RF emissions are CISPR 11 very weak and are not likely to cause interferences in a nearby electronic device RF Emissions Class B CISPR 11 a The charging power box catalogue product must Harmonic Emissions Non applicable solely be used with the device in sleep mode CEI 61000 3 2 disconnected from the patient Pulse fluctuations Non applicable Flicker CEI 61000 3 3 Table 2 Directives and MANUFACTURER S statement electromagnetic IMMUNITY For all DEVICES and EM SYSTEMS Directives and manufacturer s statement electromagnetic immunity The device is made to be used in the electromagnet
45. orax via the fixed electrode on the housing see figure 2 04 30 2015 Version Page 12 Telemedicine Station Hardcase User Manual 2 3 2 2 Peripheral leads Telecardia contains a Patient peripherals cable to plug into the ECG box right side It enables the capture of AvR AvL and AvF with limb clips dry electrodes see figure 3 3 Peripherals cable AVR AvL and AvF Limb clips electrodes 4 Peripheral cable connection The insertion mark a red point on the cord must be facing the device s top 04 30 2015 Version Page 13 2 3 3 Device control buttons To control the machine and start all the functions Telecardia has 2 buttons 1 button used to release the arms and switch the machine ON OFF located on the front of the machine and marked with a green circle crossed by a black line 1 button used to access the machine s advanced functions located under the top cover and marked OUT In addition combinations of these buttons are used to select the requested functions OUT button 5 Telecardia buttons 2 3 4 Power supply Telecardia is equipped with a separate power supply provided by a rechargeable Lithium Polymer battery allowing approximately 50 traces per charge This battery is charged using the vertical charger via 2 metal contacts integrated in the back of the device unit The vertical charger is set into a specific space in the Telemedicine Station Hardcase It ensures that the Tele
46. osys to the Touchscreen Tablet PC If no LED is lit please complete the reset procedure presented in 10 2 3 If again no lights show up please contact the customer service of PARSYS Telemedicine or its distributor and do not try to change it yourself We recommend that you NEVER ATTEMPT a modification by yourself Contact the customer service of PARSYS Telemedicine or its distributor 04 30 2015 Version Page 96 Telemedicine Station Hardcase User Manual PARSYS 11 2 5 Malfunctions related to wired sensors We invite you to check that the sensors are connected correctly the measurement protocol is followed sensors show no signs of deterioration cable cut or flattened broken sensor 04 30 2015 Version Page 97 Telemedicine Station Hardcase gt User Manual 11 3 Remote control Though if a problem persists contact the After Sales Service of PARSYS Telemedicine see section 12 The technician will maybe ask you to give him the remote control of your equipment First make sure that your equipment is connected to a communication system Ethernet WiFi or GPRS 3G and at the request of the technician please follow this procedure 24 04 2015 D 17 42 53 a Start Video Take picture Conference Start Start Oximeter ECG Start Start Temperature Glucose Edit Patient Information Press on the Help button 24 04 2015 Q 18 08 54 Support LE gt Blood Pressure L Oxi
47. r more than 1 year to keep the device s internal real time clock 10 1 6 Product scrap treatment According to the directive 2002 96 CE relating to DEEE electronic and electric devices do not throw away in regular trash Please bring waste to specialized collection points 04 30 2015 Version Page 90 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 10 2 Biosys maintenance 10 2 1 Cleaning Disinfection The device s plastic box can be cleaned and disinfected with a cotton wool or a wipe soaked in a product such as STERANIOS or equivalent 2 glutaraldehyde solution If items have been in contact with blood the recommended disinfectant is INCIDIN FOAM 10 2 2 Procedure in the event that the device is dropped or falls Mechanical damage to the device necessarily implies discontinuation of use of the device and return to the PARSYS Telemedicine After Sales Service or distributor 10 2 3 Reset procedure If the device is blocked or if the software interaction is dysfunctional simply unplug the USB and power cords located in the back of the device and wait until its battery is empty in order to reset it 10 2 4 Metrological checks The device shall undergo metrological checks after 1 year maximum Checks should be carried outby the PARSYS Telemedicine technical department it alone being able to guarantee maintenance of the device s metrological performance 10 2 5 Product scrap treatment According to the 2002 96
48. r to make the following physiological measurements pulse oximetry SpO in non invasive blood pressure in mm of Mercury 7 Front panel of Biosys 2 4 2 Wired sensors 8 Oximetry cable SPO2 9 Non invasive blood pressure arm cuff NIBP Wired sensors connect to the front panel of Biosys blood pressure cuff is connected to Biosys through a flexible tube optical oximetry sensor is connected to Biosys through a cable Sensors and accessories are supplied with the unit A N Do NOT use another model of sensors and accessories withouthaving previously validated compliance with PARSYS Telemedicine 04 30 2015 Version Page 16 2 4 3 Power socket and indicators ns PARSYS TELEMEDECINE 40 C XX 118 everue de France wal ar f X F 75013 PARIS LE eae oce PARSYS support parsys com 4 E NYO LE S N SN 0459 11401010101100 11111 01MM LII IP21 5 041 V1 4B Biosys sans ECG 2 11 Charge indicator 12 Connection indicator Connector At the rear a type B female USB plug dedicated to connecting the USB cable data Atthe rear a 2 1mm power socket Connection indicator of Biosys Off Biosys is power off Fixed GREEN Biosys is in operation Charge indicator of Biosys Off no 2 1mm power cord connected to Biosys or to the electrical mains Fixed RED Biosys internal battery being charged Fixed GREEN Biosys internal battery charged more than 95 If the charge in
49. ransmitter frequency applicable equation Recommended separation distance d 1 2VP RF conducted disturbances 3 Veff G NIE DORE d 1 2 P from 80MHz to 800 MHz d 2 3VP from 800MHz to 2 5GHz RF radiated disturbances 3 V m where P is the maximum output power of the transmitter in CEI 61000 4 3 from 80 to 2 5GHz watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m of separation It should that field strengths from fixed RF transmitters as determined by an electromagnetic survey on site should be less than the compliance level in each frequency range b Interferences may occur in the vicinity of equipment marked with the following symbol e 2 NOTE 1 to 80MHz and to 800MHZ the higher d range frequency applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM FM radio and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters it should be considered to proceed to an electromagnetic survey on site If the measured field strength in the location where the medical device is used exceeds the applicable RF compliance level above
50. re Start Blood Pressure ae Oximeter Edit Patient Information Start Start Temperature Glucose The image is displayed press on the Accept button to take a picture 04 30 2015 Version Page 48 Telemedicine Station Hardcase User Manual PARSYS exp 27 04 2015 D 11 35 17 When the picture is taken press on the Back button to continue your exams exp 27 04 2015 D 11 36 32 Finalize Help Settings The picture is displayed on the Home You can edit it by pressing on it 04 30 2015 Version Page 49 Telemedicine Station Hardcase PARSYS User Manual 27 04 2015 1 11 38 08 iiw Delete R Then you can Review Restart or Delete the picture To erase this picture press on the Delete button exp 27 04 2015 D 11 38 31 This action will destroy all data of the running examination You will not be able to undo the operation Do you still want to continue Press on the Yes button to confirm 04 30 2015 Version Page 50 Telemedicine Station Hardcase PARSYS User Manual 5 5 5 Using the Video module Check that the Webcam power indicator turns blue Start eS Start Blood Pressure ay Oximeter Edit Patient Information Start Start Temperature Glucose Press on the Record Video button exp 27 04 2015 D 11 39 37 The image is displayed press on the Record button to record a video
51. res Biosys is a device designed for use in emergency mode and outdoors Class Dimensions Weight Power Battery Protection index Operating temperature Charging temperature Temperature storage and transport Atmospheric pressure Atmospheric pressure refueling Atmospheric transport and storage Relative humidity range Relative humidity charging Standards applied 7 4 2 Oximetry SPO2 Measuring range Resolution Accuracy Pulse Rate Measurement Range Resolution Accuracy 7 4 3 Blood pressure NIBP Measurement method Measuring mode Relative humidity transport and storage lla 162 mm x 1 6 mm x 38 mm 500 g 5V Built in Lithium Polymer Battery IP20 10 40 C 10 40 C 10 50 C 700 mb to 1060 mb 700 mb to 1060 mb from 500 mb to 1060 mb 30 to 75 30 to 75 10 to 85 EN 1060 3 9919 60601 1 60601 1 2 0 100 1 2 100 80 3 79 70 0 254 bpm 1 bpm 2 or 2bpm Oscillometric o Manual Automatic 1 to 240mn interval between each measurement o Automatic adjustable cycles Measurement unit Measurement range Measurement resolution Measurement accuracy 04 30 2015 Version mmHg Adult Systolic Diastolic 15 to 255mmHg 1 mmHg 5 mmHg on average maximum 8mmHg Page 80 7 5 USB Webcam Brand Model Name Weight Connection Interface Color Resolution Microphone 04 30 2015 Versi
52. rt Video Take picture Conference Start Oximeter Edit Patient Information Start Start Temperature Glucose Press on the Start Video Conference button En 27 04 2015 D 14 56 42 fdnh on Waiting for your destination to accept the call Requis 1 21 2015 20 23 hgfgh MMM AM AM AM AMM Requis 1 21 2015 20 23 fghfdh Demo 1 1 23 2015 10 59 essai Demo 1 1 23 2015 16 30 bogue Requis 1 23 2015 19 04 test According to needs and desired configuration the connection is automatic 04 30 2015 Version Page 55 Telemedicine Station Hardcase User Manual PARSYS exp 27 04 2015 D 15 00 07 1824 Enter your message Send When the called speaker has answered the video conference request his image is automatically displayed on the screen exp 27 04 2015 0 15 00 07 aes Enter your message Send You can hang up and end the video conferencing by pressing on the Hang up button or continue the video conferencing during the exams capture by pressing on the Back button 04 30 2015 Version Page 56 Telemedicine Station Hardcase User Manual PARSYS exp 27 04 2015 1 15 01 34 You can capture all your exams To come back to the video conferencing just press again on the video conferencing image exp 27 04 2015 D 15 00 07 Hang Up To end the video conferencing press on the Hang up button 04 30 2015 Version Page 57 Telemedicine Station Hardcase PARSYS
53. se PARSYS User Manual Ver 1 3 5 6 ECG TRACE VALIDATION sicsnsiccccetesasnchonsasendencetinsnaweanesiicedatesteensannediiocsMenaendaaessaiededievnendannrdidedkiansemdaasntadceaceentens 64 561 Examinalon ol Me ECO ACE ea ea a ae eee 64 Oe IOC CI SO IOS a EE E E E EEE E E S 65 5 7 FINALIZING AND SENDING A REPORT scccccecceseeseecceceeeeeaeeeeeceeeeeeeaeaeeeeeeeeesseeesseeeeeeesssaaseeeeeeeessaaaaeses 66 571 Hanem Soon SyS lN pics den da ee de a D en sie 66 DFe PINOT OA nada ann ce de tn a D md 67 5 7 3 Consulting the reports history 70 5 7 4 Sharnga saved MEDON sciccccsesincascossends nren ir nnn EnEn aE ina e N E a EE AE EEE ERNER 72 5 8 SWITCHING OFF THE TOUCHSCREEN TABLET PC AND CLOSING THE STATION SOFTWARE 74 SOFTWARE UPGRADE INITIALISATION ccccceeeeeseceessnneeeeeeeeeeeesseeeeeeeeeooeessseeeeeeseooensnseeeeessooes 75 PRODUCTS TECHNICAL FEATURES 5 288 76 7 1 GENERAL FEATURES OF THE STATION cccccccccsssseececcceecaassseeeeecceeeasseeeeeeecsseeausseeeeeecseeeasseeeeeeessesaageees 76 7 2 OUCHSCREEN TABLE ln teens ann en dede 17 ko TELECARDIA ECO es en ts en nn de ne di ee 78 PI CON NES a ee a ae ne eae E RISA ene nme na ee eee nmna ae 78 79 2 Mechanical TOQIIICS serria a een ss enn rose etes tes EE EERENS AR RE 78 7309 HNC CHICAGO CCC AON S Se ane re dae be dires idee atelier 78 Toe FOC OMA MOIS a ee de de ee R 79 RON ins oe A wae oe send AEE 80 Vc mmm 5 62 a ene ee OP a eee ee Pee
54. se the reset cable or take a metal object paper clip and place it on the charging contacts for 1s Place the equipment back on the charger and wait for the Charger indicator to come on Establish radio connection with the PC in configuration mode in order to update the device s internal real time clock Open the cover as shown on the photo press and hold the OUT button and press on the GREEN ON OFF button at the same time When the machine displays PARSYS Sant release both buttons The machine then indicates the time and date before displaying en cours in progress and connexion BT BT connection Restart the device 11 1 5 The Telecardia ECG has lost is time stamping If your Telecardia ECG has lost is time stamping Establish radio connection with the PC in configuration mode in order to update the device s internal real time clock Open the cover as shown on the photo press and hold the OUT button and press on the GREEN ON OFF button at the same time OUT button ON button When the machine displays PARSYS Sant release both buttons The machine then indicates the time and date before displaying en cours in progress and connexion BT BT connection Restart the device 04 30 2015 Version Page 95 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 11 2 Biosys 11 2 1 Software troubleshooting screen lock Windows display Biosys comes with configured and operational s
55. t or failure of the Equipment the Customer may contact PARSYS Telemedicine by sending an e mail to support parsys com or by calling the PARSYS Telemedicine After Sales Service o Monday to Friday 10 a m 12 30 p m and 2 p m 6p m except for bank holidays o at 33 0 1 60 31 51 71 or by sending a letter by recorded delivery with acknowledgement of receipt to PARSYS Telemedicine After Sales Service 7 rue Niels Bohr 77400 Saint Thibault des Vignes FRANCE The PARSYS Telemedicine After Sales Service identifies the nature of the fault or failure of the Equipment before carrying out any repairs or replacing the defective Equipment Beyond the warranty period the Customer has the possibility of subscribing to a maintenance contract with the PARSYS Telemedicine sales department 04 30 2015 Version Page 100
56. tall the software by yourself ALWAYS contact the After Sales Service of PARSYS Telemedicine or its duly appointed distributor 04 30 2015 Version Page 20 Telemedicine Station Hardcase User Manual Ver 1 3 5 Sequences of Use Making a report 5 1 Touchscreen Tablet PC ON STANDBY OFF To turn on the Touchscreen Tablet PC press the button on the BOTTOM RIGHT of the device The screen should turn on and specify the initialization of the embedded OS If the device is just in standby mode the home screen will appear immediately To hibernate the Touchscreen Tablet PC press again and release the button on the BOTTOM RIGHT of the device The screen turns off but the device is only in standby mode To turn off the Touchscreen Tablet PC just press in the Ke Exit button on the home page or do it manually by pressing and holding the button on the BOTTOM RIGHT of the device 14 Position of the ON STANDBY OFF button on the Touchscreen Tablet PC 04 30 2015 Version Page 21 Telemedicine Station Hardcase PARSYS User Manual 5 2 Homepage When you turn on the Touchscreen Tablet PC the software homepage is automatically launched 24 04 2015 D 17 42 53 Start Video Take picture Conference Oximeter Edit 00 Start Patient Information Temperature Glucose 15 Station software Homepage Orange F Ep 17 06 2015 OLZA Q SR Real Battery ae 1 Biosys TITI Start Chargeur HID Video LE
57. to a DC outlet 1 3 2 Telecardia The device must not be used simultaneously with an electric surgery tool A The device is not intended for cardiac direct use reserved to CF class devices A The ECG capture must not be performed when the device is charging on its charger When the ECG is capturing electrodes unplugged on the patient must not come into contact with the ground or other exposed metal parts A When the ECG is capturing the device s differentiator box must be in contact with the patient A In case of a simultaneous use of the device and another it should take care that the sum of the patient leakage currents to the ground doesn t exceed safety limits A In case of a simultaneous use of the device with a defibrillator do not place the defibrillator s electrodes into contact with the device s electrodes 04 30 2015 Version Page 7 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 1 3 3 Biosys Using the device for one patient at a time Using Biosys is exclusively to medical diagnosis of a single patient at a time It cannot be used to establish a medical diagnosis of several patients simultaneously It is therefore appropriate to user Biosys to ensure that the equipment used is reserved for one patient only Presence of a high frequency surgical equipment in the area of use There may be a risk burning if using a high frequency surgical device together with Biosys in a given
58. ure proper cleaning without damaging the Telecardia components 10 1 2 Procedure in the event that the device is dropped or falls Mechanical damage to the device necessarily implies discontinuation of use of the machine and return to the PARSYS Telemedicine After Sales Service 10 1 3 Reset procedure If when using the device it blocks for more than 1 min Use the reset cable or take a metal object paper clip and place it on the charging contacts for 1s Place the equipment back on the charger and wait for the Charger indicator to come on Establish radio connection with the PC in configuration mode in order to update the device s internal real time clock Open the cover as shown on the photo press and hold the OUT button and press on the GREEN ON OFF button at the same time OUT button When the machine displays PARSYS Sant release both buttons The machine then indicates the time and date before displaying en cours in progress and connexion BT BT connection Restart the device 04 30 2015 Version Page 89 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 10 1 4 Metrological checks The device shall undergo metrological checks after 1 year maximum Checks should be carried out by the PARSYS Telemedicine technical department it alone being able to guarantee maintenance of the device s metrological performance 10 1 5 Discharged battery We recommend not to let Telecardia discharged fo
59. vel with the subject s LEFT nipple 04 30 2015 Version Page 61 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 Capture ECG 04 30 2015 Version Keep the ECG unit firmly pressed up against the chest in order to maintain the electrodes in CONTACT with the skin The ECG unit at a Slight angle Capture ECG Maintaining contact keep the button pressed down 5 sec PRESSED DOWN until the audible signal a beep or voice sounds then RELEASE it to begin capture Page 62 Telemedicine Station Hardcase PARSYS User Manual Ver 1 3 Capture ECG Keep the electrodes in contact with the skin Both you and the subject should stay as STILL and CALM as possible for the 15 seconds of capture An audible signal a beep or a voice sounds at the end of capture and automatic data transmission 04 30 2015 Version Page 63 Telemedicine Station Hardcase User Manual PARSYS 5 6 ECG trace validation Once the capture is complete the trace is automatically transmitted by Bluetooth connection and displayed on the Tablet PC s touchscreen It is possible to examine a trace in greater details by using the following functions exp 28 04 2015 D 17 14 41 5 6 1 Examination of the ECG trace The cursor allows moving around the tracing on screen The arrows can move the trace The round central button can move the cursor itself The and buttons help e
Download Pdf Manuals
Related Search
Related Contents
USER MANUAL MANUAL D'UTILISATEUR Equip 128183 FDY - Moore Industries International AIR CONDITIONER (SPLIT TYPE) Husqvarna 532 44 00-55 User's Manual Delta 2705 Installation Guide Viking F20696A EN User's Manual Samsung MS103HCE คู่มือการใช้งาน GlobalSat TR-313 WP 310 Machine hydraulique d`essai universelle, 50kN Copyright © All rights reserved.