Home
1556 KB
Contents
1. 2 13 Ref 1038 13 CALL MODULE WITH DIRECTORY SINTHES CALL MODULE Ref 1038 13 SINTHESI CALL MODULE WITH DIRECTORY CALL MODULE SINTHESI CALL MODULE WITH DIRECTORY Ref 1038 13 e Fit the module in the frame Adjust correct perpendicularity of the panel Close the frame and fasten the screw A Position the panel on the frame Fasten screw B on screw A 14 ____ 2 INSTALLATION NUMBER OF MODULES FLUSH MOUNTING BOX Purchase flush mounting boxes frames and module holders separately for wall mounting The product codes according to number of modules FRAMES AND MODULE HOLDERS 1145 52 1145 62 1145 53 1145 63 1145 54 1145 64 Refer to Technical product manual Door phone and video door phone systems Sinthesi panels section for dimensions and additional details on these products DIGIVOICE Technical Manual SINTHESI CALL MODULE WITH DIRECTORY Ref 1038 13 ACCESSORY INSTALLATION ACCESSORY INSTALLATION FLUSH MOUNTED VERSION WITH WALL COVER FRAME The wall cover frames are used to conceal possible irregularity of the wall surrounding the flush mounting box The available models and the dimensions are shown in Technical product manual door phone and video door phone systems section Sinthe
2. CALL MODULE WITH DIRECTORY SINTHES CALL MODULE Ref 1038 13 SINTHESI CALL MODULE WITH DIRECTORY CALL MODULE SINTHESI CALL MODULE WITH DIRECTORY Ref 1038 13 ACCESSORY INSTALLATION GATE SEMI FLUSHED PANEL ACCESSORIES Fit the modules on the frame Cases and hood for gate pillar installation are suitable for vertical WARNING Eliminate a crossbar with cutters to fit double modules installation on a gate pillar The available models and dimensions are shown in Technical product manual door phone and video door phone systems section Sinthesi Panels Drill a hole dimensioned as shown on the provided template in the pillar and arrange the case on the pillar ON To fasten the case Push the screw to the bottom of the box with a screwdriver b Push the screw outwards with a screwdriver c Fasten the screw 16 sec 2a DIGIVOICE Technical Manual CALL MODULE WITH DIRECTORY Ref 1038 13 ACCESSORY INSTALLATION EXAMPLES OF MODULAR CONSTRUCTIONS Reccommended calling module constructions are shown below 2 modules Ref 1038 13
3. 1 55 1 60 Ref 1145 52 Ref 1038 13 3 modules Ref 1038 13 Ref 1038 74 _ Ref 1145 53 Ref 1038 74 lt Ref 1038 13 lt colour camera Ref 1745 40 can be fitted as an alternative DIGIVOICE Technical Manual 4 modules Ref 1745 70 _ Ref 1038 13 Ref 1038 74 Ref 1145 54 Ref 1038 74 lt Ref 1038 13 Ref 1745 70 2 17 Ref 1038 13 CALL MODULE WITH DIRECTORY SINTHES CALL MODULE 18 2 DIGIVOICE Technical Manual
4. key extends the buzzer activation time When the X cancellation key is pressed in the case of an error during entry of the code the number on the display is cleared During the call any lock release command will be indicated both audibly 3 beeps and visibly with the following caption for 3 seconds DOOR OPEN At the end of the conversation or if no reply is received after approx 30 seconds the name selection message is redisplayed automatically accompanied by 3 beeps DIRECT CALLS Two particular users can be called pressing the matching keys of the Ref 1145 12 Module if present Any Ref 1038 40 Main Entrance Switchboard can be called simply pressing the key without entering any code and without selecting a name or alternatively one of the two Ref 1145 12 Module keys if present and suitably programmed ADDITIONAL CODES AND FUNCTIONS The Call Module with Repertory is able to manage three separate groups of codes Call codes 1 JJJJ Identify the house phone or video house phone indoor set called during entry codes consisting of less than four digits letters must NEVER be preceded by zeroes for example enter 12A and not 012 The call codes must always be terminated pressing the key which activates forwarding of the code Lock release codes numeric ONLY 1 99999999 Permit direct opening of the door by residents or by authorized persons these codes must always
5. lt S gt lt N gt Y e Answering YES to the first prompt ONLY the Names will be deleted SOUND LEVEL ADJUSTMENT The sound level towards the indoor set called is factory set and does not require adjustment The sound level towards the outside is factory set to a medium value To modify this use a screwdriver on adjustment 3 DISPLAY CONTRAST ADJUSTMENT Display contrast is factory set to an optimal level It can however be modified using a screwdriver on the related adjustment 11 DIGIVOICE Technical Manual ERROR CODES Various types of error codes are put on the display ERRORS DURING NORMAL OPERATION Call to a non existent user ERROR NON EXISTENT Call from a secondary call module to a user of another riser RISER ERROR At least one key is jammed KEYBOARD JAMMED Door lock release code incorrect or disabled LOCK REL NON EXIST ERRORS DURING INSTALLATION PROGRAMMING No signal on data line terminal D not connected or signal missing DATA LINE ERROR Insertion of an incorrect Password PASSWORD INCORRECT Attempt to insert a name already present in the memory ERROR NAME PRESENT Attempt to insert a name with the memory full ERROR MEMORY FULL Attempt to modify or delete a name with the memory empty ERROR MEMORY EMPTY 2 ___ 11 Ref 1038 13 CALL MODULE WITH DIRECTORY SINTHES CALL MODULE Ref 1038 13 SINTH
6. 2 lines of 16 characters each for a total of 32 characters and press Enter the call code between and JJJJ and the lock release code associated to the name numeric only between 1 and 99999999 When the specific prompt is displayed confirm sec 2a 9 Ref 1038 13 SINTHESI CALL MODULE WITH DIRECTORY SINTHESI CALL MODULE Ref 1038 13 SINTHESI CALL MODULE WITH DIRECTORY SINTHES CALL MODULE SINTHESI CALL MODULE WITH DIRECTORY Ref 1038 13 NAME MANAGEMENT Continue in this way inserting all the names At this point press the lt Esc gt key to return to the Name Management menu CANCEL MODIFY A NAME Selecting lt Cancel gt or lt Modify gt from the name Management menu the following prompt is displayed Select the name with the lt keys Scroll the names until that to be deleted modified is shown WARNING during scrolling only the first 16 characters of each name are displayed When the name concerned has been found stop without pressing any key after approx 3 seconds the remaining 16 characters of the name and the other parameters associated with these will be displayed To delete press and confirm To modify make the changes required then press and confirm NOTE when a name is deleted any associated lock release code is automatically deleted together with the name MANAGEMENT VIA KEYBOARD This type of programming can be used as an alternative method to
7. SINTHESI CALL MODULE WITH DIRECTORY Ref 1038 13 CAPABILITIES DESCRIPTION OF THE TERMINALS CALL MODULE WITH DIRECTORY Ref 1038 13 The Ref 1038 13 Call Module is based on Sinthesi mechanics with 2 modules Although it is not equipped with the embedding box and related module holder frame which can be bought separately it is complete with anti theft screw for security of installation CAPABILITIES The Ref 1038 13 Call Module with repertory provides the following capabilities Possibility of forwarding a house phone or video house phone call in combination with the Ref 1745 70 TV camera unit Automatic management of house phone and video house phone traffic according to the number of voice lines available 1 or 2 Selection using scroll keys and a 2 line 16 character back lit alphanumeric display of the name to be called Up to 740 separate names are available Direct selection via keyboard of an alphanumeric call code in combination with the Ref 1038 74 Additional Alphabetic keyboard This means that up to 159999 separate call codes are available Possibility of managing up to 2 direct call keys in combination with the Ref 1145 11 or 1145 12 module for calls to specific users or to main entrance switchboard Up to 980 lock release codes divided into two categories 240 codes independent of the names for general use plus another 740 codes associated to the individual names Up to 7999 codes
8. The Call Module makes it possible to insert up to 240 lock release codes that are completely independent of the names for general use These codes must be numeric only and each consist of a number of digits that can be selected as required between 1 and 8 Therefore the permitted range is 1 to 99999999 METHODS OF INSERTION The lock release codes can be inserted 1 Using the Ref 1038 56 Programming Terminal connected locally or at any other point of the installation 2 Locally from keyboard In this case the password for programming of the names and lock release codes must be known this is DIFFERENT from the configuration access password INSERTION USING THE 1038 56 TERMINAL After establishing a logical connection with the call Module concerned see description in PROGRAMMING WITH THE 1038 56 TERMINAL move to the following page lt Names gt lt Lock release gt lt Program gt lt Cancel gt lt Exit gt Select lt Lock release gt and press 1 The first 3 lock release codes will be displayed 001 00000000 Lockrel002 00000000 Lockrel003 00000000 lt gt lt 5 gt lt gt lt 5 gt Enter the code s required and then using the lt and keys move to the lt OK gt command and press 4 WARNING THE 3 CODES ARE EFFECTIVELY SAVED IN THE CALL MODULE ONLY FOLLOWING CONFIRMATION WITH THE lt OK gt COMMAND Saving is confirmed visibly To access the three subsequent codes select
9. be preceded and followed by pressing of the key Initial pressing of the key prevents sec 2a 3 Ref 1038 13 SINTHESI CALL MODULE WITH DIRECTORY SINTHESI CALL MODULE 1038 13 SINTHESI CALL MODULE WITH DIRECTORY SINTHES CALL MODULE SINTHESI CALL MODULE WITH DIRECTORY Ref 1038 13 PROGRAMMING display of the lock release code in which the digits are replaced with asterisks LOCK RELEASE CODE kkkkkkkk The lock release codes can be inhibited in pre established time bands using an external timed switch that operates on the H and OV terminals Special codes 1 Can be used to activate deactivate auxiliary services such as the stair lights garden lights etc Must always be preceded by a 0 which prevents display of the codes and followed by pressing of the dh key SPECIAL CODE These codes also make it possible to check the status of an input showing this on the display with the On or OFF caption for example TERMINAL STATUS ON For further information refer to the Ref 1038 80 Special Decoding box User Manual NOTE in the case of an error during entry of any code press the cancel key the code shown on the display will be cleared PROGRAMMING OF DECODING BOXES The Ref 1038 13 Call Module with Repertory can be used by the installation technician to program the decoding devices For a description of the param
10. code between 1 and JJJJ and the lock release code associated to the name numeric only between 1 and 99999999 10 2 lt Esc gt lt Del gt lt End gt 0 Lock rel 00000000 lt Esc gt lt Del gt lt End gt 0 Any errors during entry can be corrected selecting the lt Del gt item which deletes the last character inserted Use lt Esc gt to abandon the operation without saving the data entered NOTE 1 if the name inserted is already present in the memory an error message is output NOTE 2 if the code inserted is present in the memory a confirmation is requested Code present Confirm lt Y gt lt N gt CANCEL MODIFY A NAME Selecting lt DEL gt or lt MODIFY gt from the name Management menu the following is displayed FIND NAME WITH J Using the or 4 keys scroll the names present until that to be deleted or modified is reached Press the key and delete the name after confirmation or modify this proceeding as described above for insertion NOTE 1 if a name is deleted any associated lock release code is automatically deleted together with the name COMPLETE ERASURE In some cases it may be useful to delete all the lock release codes inserted for example to reinstall the same device in another building Complete erasure of the lock release codes is possible only using the keyboard From Terminal e After establishing a logical connection with the cal
11. it is connected using the specific connection cable In any case the device must be positioned BELOW or at the most to the SIDE of the Ref 1038 13 Call Module TECHNICAL DATA Power take off in unitary loads 3LU Logic circuits Power supply voltage Power take off when idle Operating temperature 15 25 2Vdc 27 10 50 C DIGIVOICE Technical Manual INSTALLATION WARNING for wiring and the maximum permissible distances follow the instructions given in the section 1 of this manual The Call Module must be installed on Sinthesi frame not provided The anti theft screw provided must be used instead of the normal screw furnished with the Sinthesi frame in order to guarantee installation security Calling module with repertory Ref 1038 13 can be used alone or in combination with a camera unit and or alphabet keyboard add on Ref 1038 74 Examples of modular constructions using 2 or 3 module holder frames with respective flush mounting boxes are shown below The door unit module should be installed at a height of approximately 1 55 1 60 metres 2 Important The module should not be illuminated from behind to make the calling module display easier to read Never direct the module towards strong sources of light e g the sun lampposts light bulbs flashes or glare FLUSH MOUNTED VERSION e Fit the flush mounting box in line with the wall it must not project
12. may be 10 20 30 or 40 seconds Electric lock management Opening of the electric lock from an indoor set may be Free FREE or With Secrecy SEC In the first case the door can be opened at any time in the second case it can be opened only during the conversation The criteria according to which the various electric locks are managed is important for correct functioning of the system ALWAYS COMPLY SCRUPULOUSLY WITH THE INSTRUCTIONS GIVEN BELOW BECAUSE ONLY THE CONFIGURATIONS DESCRIBED ARE PERMITTED e In installations with a single main call station and no secondary call station the call station can be configured either with FREE LOCK RELEASE OR LOCK RELEASE WITH SECRECY e In systems with several main call stations in automatic switching all the call modules must be programmed with LOCK RELEASE WITH SECRECY DIGIVOICE Technical Manual CALL MODULE WITH DIRECTORY Ref 1038 13 PROGRAMMING In systems with at least one secondary call station the main call station s must be programmed with LOCK RELEASE WITH SECRECY The secondary call station s can be programmed as required with FREE LOCK RELEASE OR LOCK RELEASE WITH SECRECY In the first case after a call from the main station activation of the lock release key on the indoor set called will cause opening of the lock connected to the main call station and of the lock connected to the secondary station on which th
13. the lt S gt command and press Alternatively to access the three previous codes select lt P gt and press J 2 7 Ref 1038 13 CALL MODULE WITH DIRECTORY SINTHES CALL MODULE Ref 1038 13 SINTHESI CALL MODULE WITH DIRECTORY SINTHES CALL MODULE SINTHESI CALL MODULE WITH DIRECTORY Ref 1038 13 NAME MANAGEMENT e Once the codes have been programmed select lt EXIT gt and press and then the lt key to move to the previous page select lt Exit gt and press 1 e Disconnect the programming cable and switch off the terminal pressing the OFF key for at least 3 seconds or if the same lock release codes have to be programmed on another call module connected in the system repeat the steps described above NOTE to delete a lock release code reprogram this to 00000000 ENTRY VIA KEYBOARD e Enter 00 followed by the 4 digit password for programming of the names and lock release codes and by gt key If the password is incorrect the following message is displayed INCORRECT PASSWORD After the third unsuccessful attempt entry of the password is blocked for a period of time that depends on the number of unsuccessful attempts Wait time before new password insertion No unsuccessful attempts 1 minute 2 minutes 3 minutes 55 252 minutes above 4 hours 1 2 3 4 5 6 2 Once the password has been entered correctly the display will show
14. 8 56 can be set up only for English Italian French Spanish and German 6 2 LOCAL PROGRAMMING VIA KEYBOARD It is possible to access programming in 2 ways a If the configuration access password is known the password is factory set to 9998 enter 00 followed by the 4 digit password and the key If the password is incorrect the following message is displayed INCORRECT PASSWORD After the third unsuccessful attempt entry of the password is blocked for a period of time that depends on the number of unsuccessful attempts N unsuccesfull Wait time before attempts new password insertion 1 minute 2 minutes 3 minutes 255 252 minutes above 4 hours If the password is not known open the Sinthesi frame and press the programming button 4 After inserting the correct password or after pressing the programming button 4 the following message is displayed for a few seconds v1 0B 23 03 99 N S uvwxyz The first indication refers to the SOFTWARE version in this case 1 0 and to the maximum number of programmable lock release codes 240 letter B is displayed These are followed by the date of the version and the serial number of the device S N uvwxyz coinciding with the serial number indicated on the rear label this information makes it possible to check the serial number WITHOUT opening the Sinthesi frame The main menu is then displayed lt LANGU
15. AGE gt lt CONFIG gt lt ID gt lt TEST gt lt ESC gt Using the arrow keys move the cursor to lt LANGUAGE gt and press the key to access the screen form used to select operating language The first screen form is as follows lt ITA gt lt FRA gt lt ENG gt lt DEU gt lt ESP gt lt 12 gt Move the cursor to language selected and press the key To program the installation site description move the cursor to lt ID gt and press the key The following is displayed lt Esc gt lt Del gt lt End gt A DIGIVOICE Technical Manual SINTHESI CALL MODULE WITH DIRECTORY Ref 1038 13 ENTRY OF THE LOCK RELEASE CODES Use the 7 and 4 keys to scroll the characters that can be entered Press the key to enter the character selected in the upper line of the display Although up to 30 characters can be entered starting from the time the 16th character is entered the top line scrolls progressively to the left it is advisable to restrict insertion to 15 because only 15 will be displayed in the search from Terminal Once entry has been completed position the cursor in the reduced lt Esc gt lt Del gt lt End gt menu To do this hold down the J key until the cursor is positioned on the E of lt Esc gt To confirm insertion of the name select the lt End gt item using the key and press the key Moving the cursor to lt CONFIG gt and pressing the key programming of
16. B In actual fact it is possible to insert up to 30 characters but in the fast search phase only the first 15 will be shown It is advisable therefore to restrict the name to 15 characters and to use the remaining characters for any additional information 11 parameters to be configured 1 Type of Call station It is possible to select between a Main Call station from which calls can be made to all indoor sets or to the main entrance switchboard and a Secondary call station from which calls can be made only to the indoor sets of the specific riser Call station code Each call station whether Main or Secondary is identified by a code The codes that can be assigned to a call station depend however on whether this is Main or Secondary If Main the code will be between 1 and JJJ Secondary the code will be between 1 and JJ and will indicate the riser to which it belongs Busy time The busy time defines the minimum duration of a call including the time that passes between forwarding of the call and reply by the user To guarantee this minimum duration the system may in the case of several concurrent calls set one or more call stations to Busy status which is shown on the display with the following message LINES BUSY Please wait When a Call Module has been set to Busy status it cannot be used to send calls although it can be used to enter lock release codes The busy time
17. ESI CALL MODULE WITH DIRECTORY SINTHES CALL MODULE SINTHESI CALL MODULE WITH DIRECTORY Ref 1038 13 TROUBLESHOOTING AND REPLACEMENT SELF TEST Configuration memory not present ERROR EPROM MISSING Configuration memory fault ERROR EEPROM Name memory fault TROUBLESHOOTING AND REPLACEMENT DISPLAY In the case of problems with the display check first of all that contrast is correctly set using the rear adjustment 11 A further check can also be carried out accessing by entering the configuration password or pressing the rear key the main menu lt LANG gt lt CONFIG gt lt ID gt lt TEST gt lt ESC gt Select lt TEST gt and press the key Check that the control figure is displayed At this point the matching character is displayed for each key pressed Press the key to return to the previous menu and then select lt ESC gt to restore normal functioning ELECTRIC LOCK In the case in which the electric lock fails to open the cause can be quickly traced e f the module emits beep and the electric lock does not open the fault is in the section from the module to the electric lock or in the module drive circuitry If the module not only fails to open the electric lock but does even emit a beep this means that the lock release command is not received from the module the fault is located on the indoor set side REPLACEMENT PROCEDURE
18. In the case of a fault in the module replace the entire module If many lock release codes have been programmed it is possible to remove the integrated circuit on which the codes are stored and to re insert this in the new module The name memory can be replaced in the same way e Cut off the power to the old Ref 1038 13 Call Module e Remove the rear cover applying a light pressure on the side hooks Remove the U3 and MEW 7019 integrated circuit e Remove the rear cover of the new module replace the U3 integrated 12 _ 2 circuit paying particular attention to the direction of insertion notch on the body of the component and on the socket replace integrated circuit MEW 7019 taking care to orient it correctly on installation Re place the rear cover Power on the new Call Module WARNING after replacing the memory the serial number of the new call Module automatically becomes that of the old Module remember to modify the indications on the rear label 10 by hand DIGIVOICE Technical Manual SINTHESI CALL MODULE WITH DIRECTORY Ref 1038 13 ADDITIONAL ALPHABETIC KEYBOARD Ref 1038 74 INSTALLATION ADDITIONAL Ref 1038 74 ALPHABETIC KEYBOARD The Ref 1038 74 Additional Alphabetic Keyboard makes it possible to introduce letters of the alphabet in the call code and special code composition phase The device must be combined with a Ref 1038 13 Call Module to which
19. SECTION 2 REV F CALL MODULE Download from www urmetdomus com Technical Manuals area SECTION CONTENTS CAPABILITIES TROUBLESHOOTING AND REPLACEMENT Description of the terminals Display Electric lock TECHNICAL DATA Replacement procedure FUNCTIONING ADDITIONAL ALPHABETIC KEYPAD Ref 1038 74 Call for name selection Technical data Code for call composition Direct calls 21 INSTALLATION Additional codes and functions s Flush mounted version Programming of decoding boxes ACCESSORY INSTALLATION PROGRAMMING Flush mounted version with wall cover frame Programming methods Flush mounted version with rain hood Parameters id Wall mounted version with case and hood Programming using the Ref 1038 56 Terminal Gate semi flushed panel accessories Local programming via keyboard Examples of modular constructions ENTRY OF THE LOCK RELEASE CODES Methods of insertion Insertion using the 1038 56 terminal Entry via keyboard Complete erasure NAME MANAGEMENT Management methods Management using personal computer and Ref 1038 56 terminal Management using the Ref 1038 56 terminal Management via keyboard Complete erasure SOUND LEVEL ADJUSTMENT DISPLAY CONTRAST ADJUSTMENT ERROR CODES Errors during normal operation Errors during installation programming Self test DIGIVOICE Technical Manual sec 2a___1 Ref 1038 13 SINTHESI CALL MODULE WITH DIRECTORY SINTHES CALL MODULE
20. SI CALL MODULE Ref 1038 13 SINTHESI CALL MODULE WITH DIRECTORY CALL MODULE CALL MODULE WITH DIRECTORY Ref 1038 13 PROGRAMMING Page 1 Device recognized REP and its Serial Number both non modifiable Description of the installation site Busy 10s Lock Rel 5 00 s Page 3 Call time number of lines Buzzer level Call 03 s Lines 1 Buzzer 2 Page 4 T1 and T2 key code assignment and Password Key 1 0000 Key2 2 0000 Password 9998 Language English Program all the parameters using the alphanumeric keys the lt and keys to move the key to confirm the sp key to switch between the pre established options Press the lt key several times to move to the following page lt Names gt lt Lock release gt lt Program gt lt Cancel gt lt Exit gt Position the cursor on Program and press J The terminal writes the data set in the memory of the Module and displays the result of the write operation Move to the page with the lt Exit gt option position the cursor on this and press J At this point and ONLY at this point the Call Module will exit Maintenance status and return to normal operation Disconnect the programming cable and switch off the terminal pressing the OFF key for at least 3 seconds or if other call modules connected to the system are to be programmed repeat the steps described above Note terminal Ref 103
21. USING PERSONAL COMPUTER AND 1038 56 TERMINAL The best way to manage the names is to use the DVOICE Personal Computer programs specifically designed to simplify insertion and maintenance of the names of one or more sites The DVOICE program can be downloaded free of charge from the Urmet Domus Internet site http Awww urmetdomus com The installation technician or building administrator may therefore proceed DIGIVOICE Technical Manual CALL MODULE WITH DIRECTORY Ref 1038 13 NAME MANAGEMENT e To save the names of a site on his own PC e Transfer the database of names from the PC to the 1038 56 Programming Terminal e Inject the database of names in one or more Call Modules of the site connecting the terminal at any point of the site The various operations are described in detail below SAVING OF THE DATABASE ON THE PC Using the DVOICE program create a new site on your PC and save the names of the residents together with any other relative information such as for example the lock release codes For further information refer to the DVOICE program TRANSFER OF THE DATABASE FROM PC TO THE 1038 56 TERMINAL Connect the programming Terminal to the selected serial port of the PC using the specific cable provided e set the DVOICE program to download the Database of the site on the Terminal e Switch on the terminal The following message is displayed To program connect cable lt Con
22. another two prompts will be displayed for confirmation of ONLY the Names or ONLY the Lock Release Codes Erase names lt Y gt lt N gt Erase lock release lt Y gt lt N gt e Answering No to the first prompt and Yes to the second ONLY the Lock release Codes will be deleted NAME MANAGEMENT It is possible to enter up to 740 names Each name includes the following information Name of the user maximum 32 alphanumeric characters distributed on two 16 character lines e User code alphanumeric between 1 and 4449 e Lock release code numeric only between 1 and 99999999 It is possible to proceed in such a way that several names different from each other correspond to the same call in the case of several people living in the same apartment If the call code is to be displayed beside the name simply save the call code also in the 32 characters dedicated to user name MANAGEMENT METHODS Names can be managed Using a Personal Computer and the Ref 1038 56 Programming terminal Using the Ref 1038 56 Programming Terminal connected locally or at any other point of the installation mainly for modifications cancellations and short entries Locally from keyboard mainly for modifications cancellations and short entries In this case the password for programming of the names and lock release codes must be known this is DIFFERENT from the configuration access password MANAGEMENT
23. at indoor set depends In the second case following a call from the main station activation of the lock release key on the indoor set called will cause opening of the lock connected to the main calling station only a second call must then be made from the secondary station in order to open the lock connected to this Door open time Indicates the time in seconds of duration of the electric lock maintenance current WARNING when locks that do not require latching current are used ALWAYS set the lock release time to zero In the case of low absorption locks ONLY the door open time can be set between 1 and 30 seconds Duration of call ring Indicates the duration of the call ring on the indoor set It is advisable to program the same value on all call stations Permissible values in seconds range from 1 to 5 Number of voice lines The number of voice lines including Main and Secondary in the system must be specified Settable values are 1 and 2 Buzzer Sound Level The intensity of the acoustic signals key pressed call forwarded end of conversation beeps etc can be adjusted to 3 possible levels Minimum Min Medium Med Maximum Max Code associated to Key T1 In the case of combination with a Ref 1145 11 or 12 module the code associated to pressing of the first key must be specified If this key is to send a call to a specific Main Entrance Switchboard both during the day and night but not
24. eters and programming methods refer to the decoding boxes User Manual In any case if a parameter is programmed successfully the display of the module will show Programming OK Otherwise the following message is displayed Programming KO PROGRAMMING PROGRAMMING METHODS The Call Module with Repertory can be programmed in three different ways in any case only when powered 1 Programming using the Ref 1038 56 Programming Terminal This programming method is recommended as the display of the terminal facilitates the operations involved The terminal may be connected e Locally on the programming connector 2 to the Call Module to be programmed On any other Call Module or Main Entrance Switchboard included in the system e On any Passive Plug Ref 1038 90 connected in the system 4 lt 2 Locally via keyboard without having to open the frame of the Module In this case the configuration access password must be known Locally via keyboard opening first of all the frame of the Call Module to press the rear programming button 4 PARAMETERS The following parameters must be programmed A The operating language One of the listed languages can be selected in more consecutive screen forms B Description of the installation site This is a 15 character string that must be used to assign the Call Module a mnemonic name e g Entrance V Roma Corso Venezia Stair A Stair
25. figur gt lt Database gt lt PC gt Select lt PC gt and press The following message is displayed lt PC TP gt lt TP PC gt lt Exit gt Select the lt PC TP gt item press and answer YES to the subsequent confirmation prompt transfer of the Database from PC to Terminal will start e On completion of transfer return to the main page switch off the terminal and disconnect the cable from the PC CHECKING AND MODIFICATION OF THE DATABASE Once the names Database has been loaded on the terminal it can be examined and modified To do this access the lt Database gt item from the main page and then select one of the possible options lt Display gt lt Insert gt lt Modify gt lt Cancel gt lt Exit gt TRANSFER OF THE DATABASE FROM THE 1038 56 TERMINAL TO ONE OR MORE 1038 13 CALL MODULES e After establishing the logical connection with the Call Module concerned see description in the PROGRAMMING USING THE 1038 56 TERMINAL paragraph go to the following page lt Names gt lt Lock release gt lt Program gt lt Cancel gt lt Exit gt DIGIVOICE Technical Manual Select lt Names gt and press J The name Management menu is displayed lt Insert gt lt Modify gt lt Cancel gt lt Exit gt lt REP TP gt lt TP REP gt Select lt TP REP gt press and answer YES to the subsequent confirmation prompt transfer of the Database from the Terminal to the Module selected is s
26. for special services Impulse type lock release free or with secrecy with maintenance current for timed driving from 1 to 30 seconds of a low absorption electric lock Acoustic and visible signaling of driving of the electric lock Programmable call tone duration from 1 to 5 seconds Differentiated generation of the call tone continuous tone in the case of main module intermittent tone if a secondary module Call forwarded and end of conversation acoustic signals Adjustment of service and acoustic signal intensity Interface for door open sensor Possibility of programming the names using the Ref 1038 56 programming Terminal direct access to programming for minor modifications from the external keyboard without having to use the terminal Auto insertion function without the need for dedicated wiring Provision for operation in 11 languages Italian French English German Spanish Hebrew Russian Dutch Turkish Portuguese Polish 2 lt 2 The Call Module comprises 20 200 6555665556 Two module Sinthesi front Connector for programming using the Ref 1038 56 Programming Terminal Adjustable call module s
27. h the system on e Switch on the terminal holding down the ON key for at least 3 seconds Insert the programming cable in the specific outlet 2 or alternatively on another call Module Main Entrance Switchboard or Passive Plug The terminal will be connected automatically to the data line and the following message will be shown on the display for 3 seconds Programming and then Find lt Serial Number gt lt Type gt lt Acquisition gt Select the lt Serial Number gt option The following message is displayed Serial number 000000 Enter the serial number of the Call Module given on the rear label 10 at the S N item and press 14 key The following message is displayed REP SN uvwxyz At this point the terminal is connected logically with the Call Module with Repertory REP with the selected serial number uvwxyz To indicate that the module is in Maintenance status the display of the module will show MAINTENANCE Please wait NOTE the module permits management of the electric lock also in Maintenance status both following entry of a lock release code and activation of the main entrance button or of the postman key contact At this point the following can be programmed the description of the installation site the 11 configuration parameters and the operating language divided into four pages sec 2a 5 Ref 1038 13 SINTHESI CALL MODULE WITH DIRECTORY SINTHE
28. l Module concerned see description in PROGRAMMING WITH THE 1038 56 TERMINAL move to the following page lt Names gt lt Lock release gt lt Program gt lt Cancel gt lt Exit gt Select lt Names gt and press The name Management menu is displayed lt Insert gt lt Modify gt lt Cancel gt lt Exit gt lt REP TP gt lt TP REP gt DIGIVOICE Technical Manual CALL MODULE WITH DIRECTORY Ref 1038 13 SOUND LEVEL ADJUSTMENT DISPLAY CONTRAST ADJUSTMENT ERROR CODES e Press lt key for 3 seconds The following prompt is displayed Cancel entire repertory lt No gt lt Yes gt where entire means however deletion of the Names ONLY and not of Lock release Codes Selecting YES and confirming with the key all the Names will be deleted From keyboard e Enter 00 followed by the 4 digit password for configuration access NOT the name management password The main menu is displayed lt LANGUAGE gt lt CONFIG gt lt ID gt lt TEST gt lt ESC gt e On the keyboard press the and 5 keys at the same time The display will show Erase ALL lt gt lt gt e Answering YES the Names and all the Lock Release Codes stored in the device will be deleted Answering No another two prompts will be displayed for confirmation of ONLY the Names or ONLY the Lock Release Codes Erase names lt gt lt gt Erase lock rel
29. lt Names gt lt Lock release gt lt Esc gt Select lt Lock release gt and press The first page with the first two lock release codes will be displayed Lockrel001 00000000 Lockrel002 00000000 Enter the lock release code and then confirm with the key Use the Arrows to check the codes already inserted and to move to the new codes To exit the code entry phase and return to normal functioning press the X key for at least seconds NOTE 1 instead of scrolling all the codes with the Arrow keys it is possible to find the first free space holding down the key for at least 3 seconds NOTE 2 to delete a lock release code reprogram this to 00000000 COMPLETE ERASURE In some cases it may be useful to delete all the lock release codes inserted for example to reinstall the same device in another building Complete erasure of the lock release codes is possible only using the keyboard e Enter 00 followed by the 4 digit password for access to the configuration NOT that for lock release code management The main menu is displayed 8 2 lt LANGUAGE gt lt CONFIG gt lt ID gt lt TEST gt lt ESC gt On the keyboard press the key 5 at the same time The display will show Erase ALL lt gt lt gt Answering YES all the Lock Release Codes and all the Names see below stored in the device will be deleted Answering No
30. o indicate forwarding of the call The buzzer of the indoor set called is activated for the time programmed from 1 to 5 seconds with a continuous tone Main Call Module or intermittent tone Secondary Call Module The name selected is then redisplayed and remains visible for approximately 30 seconds during which the buzzer of the indoor set can be activated again simply pressing the When the indoor set replies the following prompt is displayed DIGIVOICE Technical Manual PLEASE SPEAK During the conversation any lock release command will be highlighted both audibly 3 beeps and visibly with the following caption for 3 seconds DOOR OPEN At the end of the conversation or if no reply is received after approx 30 seconds the name selection message is redisplayed automatically accompanied by 3 beeps CODE FOR CALL COMPOSITION The code entered on the keyboard of the Call Module and optionally of the Ref 1038 74 Additional Alphabetic Keyboard is shown on the display Pressing of each key is echoed by an audible signal CALL TO 23 When the key is pressed the call is forwarded to the extension with the code entered The buzzer of the indoor set called is activated for the time programmed from 1 to 5 seconds with a continuous tone Main Call Module or intermittent tone Secondary Call Module Three beeps confirm that the call has been forwarded Subsequent pressing of the
31. peaker volume Programming button for use only when password is not known Alphanumeric display two rows 16 characters back lit Yellow back lit name selection buttons Green back lit number pad buttons with yellow back lit function buttons Cancel X Key o and Call v Additional alphanumeric keyboard 1038 74 connector Extractable terminal strips for system connections MP1 MP2 MS Label with indication of the serial number S N of the device Adjustable LCD contrast Extractable terminal strips for local auxiliary services MA and video signal MV DESCRIPTION OF THE TERMINALS MP1 Main terminal strip V Power supply positive 24V OV Power supply and data line ground D Data line FA1 Voice circuit 1 to conductor FB1 Voice circuit 1 return conductor MP2 Main terminal strip FA2 Voice circuit 2 to conductor FB2 Voice circuit 2 return conductor F Voice circuit power supply positive 33V OF Voice circuit ground MS Secondary terminal strip V Power supply positive 24V oV Power supply and data line ground D Data line FA Voice circuit to conductor FB Voice circuit return conductor DIGIVOICE Technical Manual CALL MODULE WITH DIRECTORY Ref 1038 13 TECHNICAL DATA FUNCTIONING MA Auxiliary terminal strip SE Electric lock driving output negative SE Electric lock driving output positive OV Keys contacts button
32. s common T2 Input Key 2 for dedicated call T1 Input Key 1 for dedicated call SP Door sensor input H Lock release code inhibition contact input P Postman key contact input PH Main entrance locking button input MV Video terminal strip V Ref 1038 68 video relay box power supply SC Ref 1038 68 video relay drive output riser SL Ref 1038 68 video relay drive output local 512 Ref 1038 68 video relay drive output channels 1 and 2 OV Ref 1038 68 video relay box ground 51 Ref 1032 9 video relay drive output for channel 1 52 Ref 1032 9 video relay drive output for channel 2 OV Ref 1032 9 relay devices ground TECHNICAL DATA Power take off in unitary loads 15LU Logic circuits Logic p s voltage V OV Maximum current draw 15 25 2Vdc 400 Voice circuits Voice circuit p s voltage F OF Operating temperature 30 36Vdc 10 50 C FUNCTIONING CALL FOR NAME SELECTION In normal functioning the repertory displays the message inviting the user to select the name to be called Select NAME with or J Using the two scroll keys 6 it is possible to select the name to be called At this point simply press the dM key to send call to the name selected The following message is displayed CALL MADE NOTE if the user simply presses the key when invited to select the name a call will be forwarded to the main entrance switchboard Three confirmation beeps are emitted t
33. si Panel Embed the flush mounting box in the wall position the wall cover frame and fasten the module holder lower screw Frame fastening is completed by tightening the upper frame screw last vt AN T Ti ASA KA Men 2 Q FLUSH MOUNTED VERSION WITH RAIN HOOD Rain hoods are used to protect the calling module from the weather The available models and the dimensions are shown in Technical product manual door phone and video door phone systems section Sinthesi Panels Embed the flush mounting box in the wall position the waterproof hood and fasten the module holder lower head Hood fastening is completed by tightening the upper frame screw last AN AN KW atii fs DIGIVOICE Technical Manual WALL MOUNTED VERSION WITH CASE AND HOOD The case and hood is provided with frame and module holder The available models and the dimensions are shown in Technical product manual door phone and video door phone systems section Sinthesi Panels Fasten the hood to the wall by means of three bolts Arrange the hole for passing the wires through the lower area of the casing and the head Fit the modules in the frame then position the panel 2 15 Ref 1038 13
34. tarted e Once transfer has been completed disconnect the cable and switch off the terminal pressing the OFF key for at least 3 seconds or if the same database is to be programmed on another call module in the system repeat the steps described above NOTE in the case of a database with many names transfer may take a number of minutes A horizontal square bar will indicate state of completion TRANSFER OF A NAMES DATABASE FROM ONE CALL MODULE TO ANOTHER OR TO A PC To copy the names from one call Module to another use the Terminal Establish a logical connection with the first Module that from which the names are to be copied and select first of all lt Names gt and then lt REP TP gt the names database will be copied on the terminal At this point it can be downloaded on another call module or changing the cable of the Terminal on PC MANAGEMENT USING THE 1038 56 TERMINAL After establishing a logical connection with the Call Module concerned see description in PROGRAMMING WITH THE 1038 56 TERMINAL move to the page lt Names gt lt Lock release gt lt Program gt lt Cancel gt lt Exit gt Select lt Names gt and press The name Management menu is displayed lt Insert gt lt Modify gt lt Cancel gt lt Exit gt lt REP TP gt lt TP REP gt INSERTION OF A NAME Select lt Insert gt The following message is displayed Code 0000 Lock 00000000 Enter the Name on a maximum of
35. that described above only for minor operations such as for example insertion modification or deletion of a single name Enter 00 followed by the 4 digit password for programming of the names and lock release code and by the key If the password is incorrect an error message will be output for further details see the paragraph on insertion of lock release codes using the keyboard Once the correct password has been inserted the display will show lt Names gt lt Lock release gt lt Esc gt Select lt Names gt and press The Name Management menu will be displayed from which to access all the functions lt ADD gt lt gt lt MODIFY gt lt ESC gt INSERTION OF A NAME Selecting lt ADD gt the following is displayed lt Esc gt lt Del gt lt End gt A Use the T and J keys to scroll the characters that can be entered Press the key to enter the character selected in the upper line of the display starting from the 16th character of the name the upper line will be gradually shifted to the left It is possible to insert up to 32 characters Once entry has been completed position the cursor in the reduced lt Esc gt lt Del gt lt End gt menu do this hold down the J key until the cursor is positioned on the E of lt Esc gt To confirm insertion of the name select the lt End gt item using the key and press the key Continue as described above to insert the call
36. the 11 configuration parameters distributed in subsequent screen pages is accessed MODE TYPE lt MAIN gt lt SECOND gt MODULE CODE JJJ BUSY TIME 10s lt 10 gt lt 20 gt lt 30 gt lt 40 gt LOCK RELEASE TYPES lt FREE gt lt SEC gt DOOR OPEN T 05 lt gt lt gt lt OK gt CALL 35 lt 1 gt lt 2 gt lt 3 gt lt 4 gt lt 5 gt VOICE LINES 1 lt 1 gt lt 2 gt BUZZER MED LEV lt MIN gt lt MED gt lt MAX gt KEY 1 0000 0000 KEY 2 0000 0000 PASSWORD 9998 9998 In all the screen pages the programming method is identical e Using the arrows move the cursor to the option selected and then press the key to confirm and move to the next screen page e In screen pages in which a code must be inserted use the numeric keys and alphabetic keys if the Ref 1038 74 additional alphabetic DIGIVOICE Technical Manual keyboard is used To correct any errors and restore the all data saved press the X key Once programming has been completed the main menu is redisplayed lt LANGUAGE gt lt CONFIG gt lt ID gt lt TEST gt lt ESC gt To restore normal functioning select lt ESC gt and confirm with the gt key NOTE to interrupt programming at any time return directly to normal functioning simply press the key for than 3 seconds this case the data entered so far will remain however valid ENTRY OF THE LOCK RELEASE CODES
37. when off program the indoor set code of the Main Entrance Switchboard If the key is to send a call to any switchboard present that is in day A condition program 0000 Programmable codes are between 0000 and 9999 10 Code associated to Key T2 This is the code associated to the second key of any Ref 1145 12 module Programmable codes range from 0000 to JJJu 11 Saving of the Configuration Access Password and automatically of the lock release code programming password The password must be numeric ONLY and must consists of 4 digits The password programmed in this way can then be used to access module configuration without having to open the Sinthesi frame Programming of the configuration access password automatically enables a second password that can be used to program name and lock release codes This second password is derived from the first with an increment of 1 If for example 1234 has been programmed the name and lock release code programming password will be 1235 The installation technician can therefore reveal to others system administrator porter etc ONLY the name and lock release code programming password avoiding any risk of access also to configuration parameters The values that can be programmed range from 0001 to 9998 DIGIVOICE Technical Manual PROGRAMMING USING THE Ref 1038 56 TERMINAL Programming using the terminal must be carried out wit
Download Pdf Manuals
Related Search
Related Contents
Samsung NW2 - Réfrigérateur de 17,8 pi³ à portes françaises, 3 portes (acier inoxydable) Manuel de l'utilisateur Manual del operador As teclas de operação - Agilent Technologies Samsung Home Theater Blu-ray 3D 500W HT-F4505 manual do usuário Mise en page 1 Samsung SW674AS User Manual Liebherr IK 1610 Comfort Soméco Promotion du 15/10/2015 au 15/01/2016 RH800C USER`S MANUAL Copyright © All rights reserved.