Software to digitize electrocardiograms and quantify heart rate
Contents
1. Gordon R J Cohen An efficient algorithm for spectral analysis of heart rate variability IEEE Trans Biomed Eng 33 1986 900 904
2. Jersey 1987 A C Moore Working with Waveforms Delphi Informant Magazine 2002 7 C Petzold Sound and Music in Programming in Windows The definitive developer s guide to the Windows 98 API eds pp 993 1089 Microsoft Press 1998 D 8 A Machado E R Migliaro P Contreras F Coro Automatic filtering of RR intervals for heart rate variability analysis Annals of Noninvasive Electrocardiology 5 3 2000 255 261 9 JJ Bailey A S Berson A J Garson Recommendations for standardization and specifications in automated electrocardiography Circulation 81 1990 730 739 10 C Lerma O Infante M V Jos Sistema de captura y an lisis de la variabilidad de la onda del pulso arterial y de la frecuencia cardiaca ELECTRO 2002 2002 447 450 11 M C Teich S B Lowen B N Jost K Vibe Rheymer C Heneghan Heart Rate Variability Measures and Models Ch 6 in Nonlinear Biomedical Signal Processing eds Akay M pp 159 213 IEEE Press New York 2000 12 G P Moore D H Perkel J P Segundo Statistical analysis and functional interpretation of neuronal spike data Ann Rev Physiol 28 1966 493 522 13 M Brennan M Palaniswami P Kamen Do Existing Measures of Poincare Plot Geometry Reflect Nonlinear Features of Heart Rate Variability IEEE Transactions on biomedical engineering 48 11 2001 1342 1347 14 D R Cox V Isham Point Process in eds pp Chapman and Hall 1980 15 R D Berger S Akselrod D
3. Software to digitize electrocardiograms and quantify heart rate variability in humans Andr s Machado Garcia Mario Est vez Baez Abstract A computer program for acquiring the ECG signal discriminating the R wave peaks and measuring automatically the RR intervals for quantifying heart rate variability HRV is presented The software uses sound cards included in most of the current personal computers to digitize the ECG signal Starting from the RR intervals obtained by this method or imported from ASCII data files the software calculates the main measures in both the time and frequency domain frequently used for HRV studies These indexes can be exported to comma separated values file format to introduce them in many of the existing professional software used for data processing The program includes a filtering option that automatically detects removes or corrects wrong RR interval values according to an algorithm previously published Keywords Heart rate variability Computer programs Signal analysis Introduction Heart rate variability HRV in humans has been recognized as an index to study several pathologic conditions of the cardiovascular and nervous systems It has also been used to evaluate the magnitude of mental effort and stress to assess the state of fetuses and comatose patients and to study heart rate fluctuations in psychophysiologic investigations as well as to evaluate quantitatively the activity of the autonomous
4. al topics of Dr Eduardo Migliaro and his research group at the Physiology Department Faculty of Medicine University of the Republic Montevideo Uruguay We also thank the help given in the validation of the acquisition and measurement of intervals module to Profr Oscar Infante and to Eng Salvador Cort s of the Electromechanical Instrumentation Department National Institute of Cardiology Ignacio Chavez Mexico City References 1 Task Force of the European Society of Cardiology and North American Society of Pacing and Electrophysiology Heart rate variability Standards of measurement physiological interpretation and clinical use Circulation 93 1996 1043 1108 2 G G Berntson J T Bigger Jr D L Eckberg P G Crossman P G Kaufmann M Malik H N Nagaraja S W Porges J P Saul P H Stone M W Van der Molen Heart rate variability Origins methods and interpretative caveats Psychophysiology 34 1997 623 648 3 J Niskanen M P Tarvainen P O Ranta aho P A Karjalainen Software for advanced HRV analysis Computer Methods and Programs in Biomedicine 76 2004 73 81 4 E R Migliaro R Canetti P Contreras M Hakas Heart Rate Variability Short Term Studies are as Useful as Holter to Differentiate Diabetic Patients from Healthy Subjects Annals of Noninvasive Electrocardiology 8 4 2003 313 320 5 S Marple Digital Spectral Analysis with Applications Englewood cliffs Prentice Hall International New
5. and a table with some of the statistical results are shown Wariable Vavel RMSSD SD short term HRY 38 3 ms SDAlongterm HRY 91 9 ms ispvso2 042 SD iMeanto00 46 nu SD2iMesn 00 108 7 nu interval ms 600 300 1 000 interval ms Figure 7 Joint Interval Histogram of a young female subject and all the numerical results obtained through the YFC32 s Sequential Analveis antian 3 022F 1001irz de PSO 2 2Mz Figure 8 Example of the Wech s periodogram of the RR intervals and the main spectral results The sequential analysis includes among others tests the Joint Interval Histogram also called Poincare or Phase Diagram This graph is presented in the Fig 7 jointed with a table that contains all the analytical results obtained through this type of analysis A Welch s Periodogram is shown in the Fig 8 using the Hann window and including 1024 points in the frequency domain The RR intervals were previously interpolated at 4 Hz using the Berger s algorithm also be shown a table with some of the numerical results of the VFC32 s spectral analysis option Mode of availability It is possible to obtain this software in a free way sending an electronic mail to the authors to the following address vfc32 fbio uh cu This email must include the applicant s data and explain shortly the use that will be given to the software Acknowledgements The authors thank the decisive collaboration in sever
6. bars correspond with the recordings made by Migliaro et al in Montevideo the white bars represent the comparison done at the National Institute of Cardiology Ignacio Chavez Mexico City The user s interface This software has a main menu by which the user may access the different options offered Data Windows and Help In the Data menu one can open a previously saved ASCII file with a sequence of RR intervals or acquire an ECG signal through the line in plug of an audio card of the PC to digitize it and measure the RR intervals When a user chooses a file with RR intervals a so called Tachogram RR values vs Interval number Fig 2 is shown in the software s main panel Then in the Data menu the Filter Editor and Export HRV Results options are shown Also the options for obtaining the time and frequency domain indexes of heart rate variability are activated Fig 2 VFC32 a22F1001Irz dat 100 20 Ww WH o v mO HO o 1000 1100 1200 130 1400 terval Nunber Figure 2 Tachogram of a healthy person This is the first graph shown by the software when a file with RR interval data is opened All graphics in VFC32 may be size adjusted according to the user s needs The Filter option allows to automatically detect remove or correct wrong RR interval values according to the algorithm explained in 8 the Editor allows the user to check visually all the RR interval values of the file and to make changes manually This option inc
7. dth of 30Hz 100KHz although the best ones have a bandwidth of 10Hz 100KHz For HRV analysis it is necessary to calculate with the highest possible precision and accuracy the RR intervals but it is not indispensable to record faithfully the low frequencies of the QRS complex The deformations that occur digitizing the ECG by means of a sound card with a minimum cut off frequency higher than that recommended by the ECG norm 9 does not avoid detecting faithfully the fiducial point of the R wave therefore calculating the RR intervals with an error smaller than 1 ms when digitizing the ECG with a sampling frequency of 4KHz which is the minimum possible with sound cards To validate the methods of acquiring an ECG signal and of measuring the RR intervals implemented in the VFC32 software comparisons of ECG recordings and of RR interval values were done using simultaneously our system and either of two methods previously validated in the literature A group of researchers headed by MD Eduardo Migliaro carried out 7 ECG recordings from different subjects using a Fukuda FJC 7110 electrocardiograph whose analogical output was digitized in parallel by two personal computers In one PC the digitalization was made through an acquisition card DAQ 1200 National Instrument Company using the software Axotape Out of line another software programmed in MatLab was used to calculate the RR intervals procedure described in 4 In the other computer the s
8. e the digitized ECG signal in audio files format wav and to compress them On the other hand the next version will include the creation of custom reports that facilitate the printing of the processed results Sample of Runs In this selection we present an example of the VFC32 s main options execution using the same data showed in the figures 2 and 3 By means of the VFC32 s acquisition module we digitize an ECG register made through a conventional electrocardiograph Cardiofax Nihon Kohden to a young female volunteer person This subject was asked to sit comfortably in an armchair and was connected leads to her arms and to the left leg The obtained record Fig 3 was saved in an ecg file and then the RR intervals was calculated and stored in an ASCII file Starting from this file the corresponding Tachogram can be shown Fig 2 as the first HRV index The figures 6 7 and 8 shown some of the main HRV index that software offers calculated from the previous mentioned RR intervals The Fig 6 shown the Interval Histogram of the beat to beat measurements and a table that contain some of the statistical results of the non sequential analysis a22F1001Irz dat Standard Deviation 0 008 peciem el Varabitiy of Variabili ooo roby or me dae Probabil Sa the smun 0 004 a piy i bal pi 850 300 950 Figure 6 Non sequential analysis results example The Interval Histogram estimator of the Probability Density Function
9. er s manual and the Help of the program In the VFC32 last functional version the discrimination procedure of the R wave and the measurement of the RR intervals are done automatically by amplitude discrimination For this the user must displace horizontally an amplitude discrimination level to be sure that all the peaks of the R waves in the ECG recording are above this level Afterwards the system automatically calculates the RR interval between the successive peaks detected and shows them numbered sequentially in a window These values may then be saved During the discrimination procedure the program uses the value set by the user in the Refractory Time window Fig 4 This so called Refractory Time is the time during which the software will not recognize as valid a second peak in the recording after having detected a previous one This procedure eliminates some ectopic beats Sampling rate Hz Refractory Time ms Seconds per plot OK 4000 v 1250 10 a i aud f Cancel Defaut Audio Input Device anai ogaao Te Bis per sample e Figure 4 Dialog window that allows setting the sampling frequency the so called Refractory time used by the amplitude discrimination option the time of recording to be shown in each vandow page during the digitizing procedure and to select one of the audio cards of the PC At present the program works with a set value of 8 bits per sample Non sequential Menu By this option o
10. f the main menu it is possible to quantify the HRV through the Probability Density Function of the RR interval series which is estimated by the Interval Histogram of the beat to beat measurements 11 The Non sequential analysis includes the following options e Intervals Shows a table with the values of the frequency distribution of the RR interval values Each of the interval classes present in the series its frequency and corresponding probability are shown in this table e Statistics Shows central tendency and dispersion statistical indexes together with other values of the RR interval data distribution e Time Interval Histogram Shows the graph of the Interval Histogram of the beat to beat measurements e Survival Function Shows the graph of the way to estimate the Survival Function 12 which is constructed from the histogram of the intervals between heartbeats A window shows the time that should elapse with 95 probability before the next heartbeat appears e Distribution comparison Shows the analytical and graphical results of applying a hypothesis test to compare the real RR interval distribution with the corresponding normal theoretical distribution The hypothesis test used is the Kolmogorov Smirnov test applied at p 0 05 A window shows the maximal differences both real and theoretical a comment saying if the RR interval distribution does or does not differ significantly from the corresponding Gaussian theoretical distribut
11. ion as well as the values of the Skewness and Curtosis of the real distribution Sequential Menu This menu allows making a sequential analysis of the RR interval series by both analytical and graphical methods for studying the possible temporal dependencies between successive RR intervals or between those even farther away This menu includes the following options e Joint Interval Histogram 12 Shows a graph of joint intervals in which each RR interval value is plotted against the previous one it is also called a Poincar 13 plot or a Phase Diagram e Serial Correlogram 14 Shows a graph with the results of the calculation of 50 serial correlation coefficients e Autocorrelogram 14 Shows a graph with the Autocorrelogram of the analyzed recording e Statistical Indexes RMSSD 1 NN50 count 1 pNN50 1 pNN5 Mean number of consecutive intervals that differ by more than 5 of the mean interval value divided by the total number of RR intervals in the recording SD1 13 SD2 13 SD1 SD2 SD1 in normalized units SD1 mean RR interval 1000 SD2 in normalized units SD2 mean RR interval 1000 Spectral Menu This menu offers 3 options e FFT Spectrum Allows graphing the Welch s Periodogram 5 based on the FFT algorithms This method is applied to a signal constructed from the RR interval values after resampling them at a fix frequency using the Berger algorithms 15 e FFT Bands Shows the power by frequency band tha
12. ludes the Cut and Paste On the other hand the Export HRV Results allows operations of Windows exporting all the numeric results calculated by VFC32 to a file with comma separated values format csv Acquire an ECG option This option allows to digitize the output analog signal of any ECG amplifier that is introduced through the line in plug of a commercially available and conventional audio card of the PC been used An ECG recording digitized using VFC32 and the audio card Sound Blaster PCI 128 is shown in Fig 3 a Acquire a22F1001 rz ecg 45 06 46 40 4678 47 16 4754 4792 4830 4867 4905 49 43 4981 5019 5057 5095 0 lt gt 1200128 20 00 min Bbits 4000 Hz pm Figure 3 Window of the Acquire an ECG option The tool bar shows buttons that allow access to the digitizing reading and discrimination options The tite bar shows the name of the file that is open When the Acquire an ECG option is selected a window showing a tool bar with several buttons will appear Fig 3 These buttons allows selecting the sound card settings Fig 4 to digitize an ECG to save or open the signal in an ecg file a proprietary format They also allow editing and measuring on the digitized ECG recording select parts of the recording to be saved independently export the digitized signal to files with ASCII formal and to measure the RR intervals and save them in ASCII file format The procedure to digitize an ECG signal is fully described in the us
13. nervous system 1 2 Most of the commercial software developed for the study of HRV are very expensive and depend on the existence of a specific hardware installed in the PC thus rendering them non portable On the other hand the good known free software such as 3 depend on the previous installation of a professional etc or at least on the installation of the LabView platform MatLab corresponding function libraries thus this type of software consumes much memory internal of external These free software also require additional equipment for recording the electrocardiographic ECG signals discriminating the peaks of consecutive R waves and measuring the corresponding beat to beat intervals since they process the list of successive RR intervals Our aim has been to develop a small stand alone software VFC32 that can be used in most of the current personal computers without the need of installing special hardware neither other software components This is a self contained software for doing HRV studies since it allows to digitize ECG signals discriminate the R wave peaks measure automatically the RR intervals and process their values with both time and frequency domain analyses Another of its advantages is its portability because it can be used in almost any PC with a commercial sound card Background Our research group has developed software for studying different biological phenomena that can be considered as point proces
14. p the parameters of the audio card for digitizing the analog output signal from conventional electrocardiographic equipment After the ECG recording is digitized the user may discriminate by amplitude the R waves and the program will automatically measure the consecutive RR intervals the values of which may be stored in a file The values of the RR intervals may be processed using 3 different types of statistical and graphical procedures non sequential sequential and spectral analyses VFC32 has a data editor by which the user may make changes to the files with the RR interval values and that includes the Cut and Paste The program also offers the possibility of filtering operations of Windows the RR intervals to detect remove or correct wrong data values described in 8 The user observes the changes evoked by this filtering procedure in the HRV indexes instantaneously Validation of the method to digitize the ECG signal and measure the RR intervals The Analog to Digital converters used to digitize the ECG must have a sampling frequency between 250Hz and 500Hz 1 although some Holters system use 128Hz and a bandwidth of 0 5Hz 100Hz is accepted as valid although it is recommended to be of 0 05Hz 100Hz 9 The sound cards are Analog to Digital converters of specific purpose designed to digitize signs with frequencies inside the range of audible frequencies They usually have sampling frequencies starting from 4KHz and bandwi
15. rithms included in VFC32 have been optimized in such way that their efficiency will be appropriate Special emphasis was made in the study of the complexity of the methods used in the spectral analysis as well as in those related with the construction of the interval histogram For the estimation of the RR interval power spectral density a non parametric method based on the fast Fourier transform O n log n well known as Welch s periodogram 5 was used On the other hand the algorithm Bin Sort O n is used to sort the intervals and for the calculation of the frequency distribution in order to estimate the probability density function of the intervals by means of its histogram System Description This program allows the user to compare visually results of different HRV indexes from two or more recordings The user also has the possibility to simulate experiments of the type what happens if since one can modify the initial data and directly observe the changes evoked in the HRV indexes VFC32 includes a special module for direct data acquisition which allows digitizing an ECG signal by using conventional audio cards present in most PC nowadays Using low level Waveform Audio Input and Output functions 6 the 7 the program automatically most utilized multimedia feature of Windows detects the configuration of the audio card or cards of the PC that will be used for digitizing on line the ECG recordings It will properly setu
16. ses We have designed a package of hierarchies of object oriented classes named PointProcess to represent the mathematical tools used in the quantification of point processes Starting from this package we developed software to quantify spike unitary neuronal activity both spontaneous and under stimulation and a system for HRV analysis initially programmed over the MS operating system DOS This was our first version of a program for HRV analysis that receives through the parallel port of a personal computer TTL pulses corresponding to each heart beat Starting from this signal the software calculates the RR intervals described in 4 and allows to apply different methods to quantify the HRV This software requires external equipment for detecting the R wave peak and converting it to a TTL pulse To avoid these inconveniences and to be able to operating system we developed the software VFC32 use Microsoft Windows Design considerations VFC32 is a software developed on Borland Delphi 6 0 which allows the calculation of a series of indexes commonly used to study HRV in humans using the nomenclature and the definitions settled down in 1 These time and frequency domain indexes are calculated from the values of the beat to beat intervals Previous installation of any libraries of functions is not necessary all its functionality is included in an executable of 333 KB Optionally a help file and a user s manual can be installed All the algo
17. t have been shown to correlate with known physiological mechanisms 1 which influence heart rate variability The bands analyzed are the Very Low Frequency VLF the Low Frequency LF and the High Frequency HF components of the power spectrum together with the Total Power TP of the spectrum The energy values of these bands appear in ms2 in percentage values and also in normalized units n u calculated by the following relations 1 LF TP VLF x100 and HF TP VLF x 100 The peak frequencies in Hz and the ratio LF HF are also calculated e Settings Allows selecting the values of the parameters that will be used to estimate the power spectrum Fig 5 Ports in frequency domain Spectrum Frequency Bands eee 3i roetan an Mn Max wee E CO u v Interpolation Rate Ha Wedow width 1024s uF io O Window Overlap 1512 HF hz TE Figure 5 The Settings dialog of the Spectral Analysis Menu allows setting The number of points to be processed in the frequency domain to calculate the power spectrum The type of FFT window that vall be used and that can be selected among the follovang Hann Hamming Rectangular and Blackman The frequency that will be used as interpolation rate for the resampling of the RR interval series The order of the autorregresive model not functional at present The limits of the frequency bands that will be used The total power is calculated from the minimal value set at the vandow of the
18. very low frequency VLF component to the maxmal value set at the window of the high frequency HF component Status report and Future plans The present software version 1 5 1 is fully functional VFC32 runs on operating systems 9x or higher The Windows personal computers with Microsoft program requires at least about 350 KB of hard disk memory about 900 KB including the help system and the user s manual 64 MB of RAM and an audio card appropriately installed on the PC This software has already been used in the following institutions Faculty of Medicine University of the Republic Montevideo Uruguay Faculty of Psychology Warsaw University Poland Faculty of Biology Havana University Cuba National Institute of Cardiology Ignacio Chavez Mexico City Faculty of Sciences UNAM Mexico City and recently in the Centro de Investigaciones y Rehabilitaci n de Ataxia Hereditaria Holguin Cuba VFC32 can be used both for clinical research and for normal population studies The next version of the software VFC32 will contain a database module that will allow creating access manipulating and recovering information using ActiveX Objects compatible databases through the Microsoft Microsoft s Access framework ADO This database system will store the HRV indexes obtained with VFC32 and will facilitate HRV studies because the information will be processed in different ways We also plan to include the possibility to stor
19. ystem VFC32 was used to digitize the ECG signal introduced through the line in plug of a sound card and to measure the RR intervals A similar test with ECG recordings from 10 different subjects was carried out at the Department of Electromechanical Instrumentation of the National Institute of Cardiology Ignacio Chavez Mexico City In this case the comparison was made using a device developed at this department described in 10 In each one of these tests two lists of RR intervals were obtained from each of the ECG recordings digitized in parallel and processed by different software to measure the beat to beat intervals The difference and its quadratic error in for corresponding intervals were calculated Fig 1 The mean SD of these comparison were 0 66 0 35 with a range from 0 20 to 1 35 The number of RR intervals measured in each subject varied between 321 and 797 The result of these comparisons indicates that the RR intervals obtained by these different methods are equivalent oO oe Oo o gt o D A O x c S E w 9 p 3 3 3 o N o D 9 O RSO_Filt Figure 1 Comparison of the RR interval values obtained by two computers working in parallel In one of the PC the VFC32 software was executed and in the other PC a previously validated method was used see text Each bar represents the quadratic error in obtained when comparing a pair of intervals of each list The shady