NView iEMS V2.0 Installation and Deployment Manual
Contents
1. 32 Installing the Nview IEMS AE 32 Launching the NView iEMS Server in HP OpenView NNM 33 Installing NView Series EMS in Integration Mode 33 Launching the Application Component of NView iEMS in HP OpenView NNM 34 Launching Device List in HP OpenView NNM 35 Launching the Nview Series EMS in HP OpenView NNM 36 Uninstalling the NView iEMS System in the Integration Mode 3 Appendix A FAQ eee 39 www raisecom com Installation and Deployment Manual Chapter 1 Preparation for Installing NView iEMS V2 0 Overview NView iEMS is a new generation of Integrated Equipment Management System EMS developed by Beijing Raisecom Technology Co Ltd It realizes the centralized management of network equipment i e IEMS not only provides the standard function of Alarms and Security for network management but also centralizes the management of various equipments via playing the part of EMS Container by using its function of integrating Raisecom Technology Co Ltd presents version V2 0 of NView i
2. Figure6 3 Extended Properties This page is for edition of the extended properties of device You can double click the property in value unit and change its default value Fill in all the necessary information and then click OK button to process the operation of adding node After the successful operation the dialog close and a device node is added in the Device List Launching the EMS Choose a node in the node tree shown in the Device List pane and then right click the device node There will be a Management item in the menu list which pops up as following figure P Control Pane 5 System 9i Device List noms Gl 492 168 1252 Ww w o E Properties f Edit lil Delete amp Current Alarms History Alarms Management Related Resources F MIE Browser b Figure6 4 Right click Menu of Node Click the Management item to launch corresponding EMS in which configuration and management can be performed The EMS window is shown as following figure 192 168 1 252 RC002 EMS SEE File Config C Command D Help aai e G z 4 4 M eee x iChassis x 2Chassis Hl Bi chassis 0 uU Pe 2Module Chassis i Premise Info je 4Module 7 je 5Module je SModule RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC Pe 3Module e ess T OOo Iolo lolol io e 14Module RaiseCom RCO002 16 Pe 15Module si j k E
3. Extracting the Compressed Installation Files After choosing the setup language the installation program starts to extract the compressed files 4 E ASK Vision Creates Future Pe SUA i Lu 20gp4d InstallShield Wizard fx RCD Element Management Setup is preparing the InstallShield x Wizard which will quide you through the rest of the setup process Flease wait BBHESESEBBEHS Cancel Figure 5 2 Extract the Installation Files Then the welcome page will be displayed as following figure RCOO Element Management Welcome to use RCOOZEMS Setup programs tis strongly recommended that you exit all Windows programs before running this Setup program Click Next to continue with the Setup program Cancel Figure5 3 Welcome Page To continue the installation please click lt Next gt To exit the installing process click lt Cancel gt After clicking lt Next gt the installation system will check the running environment automatically and the checking steps are as follows gt There must be a NView iEMS system which has already been installed in this PC If there is no NView iEMS system in your computer a dialog box will pop up as following figure Severe C2 Please install the NView system First the setup process will be terminated Figure5 4 Dialog Box of Prompt After clicking OK the installation program will exit Then please install NView iEMS syst
4. SERVICE The operation process is as follows gt Open the system services list windows by Control panel Management tool Service path The list of services is shown as follow 9 Services Action View 4 Routing and Remot Sa RunAs Service fy ScriptBlacking Service Security Accounts iy Server iy Smart Card Sa Smart Card Helper Sa SNMP Service amp SNMP Trap Service Services Local fy Symantec Network fy Symantec Password Symantec Proxy 5e iy SymwMI Service iy System Event Motifi Siy Task Scheduler Sia TCP IP NetBIOS Hel Sa Telephony Telnet Figure9 1 Windows Services List Select the SNMP Trap Service in the list double click it and the SNMP Trap Services Properties dialog is shown as following figure Bn Uninterruptible Paw Offers routing services to bu Enables starting processes U Stores security information F Provides RPC support and Fil Manages and controls acces Provides support Far legacy Includes agents that monitor Receives trap messages gen Symantec Event Manager Symantec Network Drivers 5 Symantec Proxy Service Symantec WMI Service Tracks system events such a Enables a program to run at Enables support Far MetBIOS Provides Telephony API TA Allows a remote user tolog Manages an uninterruptible Started Started Started Started Started Started Started Started Sta
5. Choosing Installation Mode 13 Confirming the Installation Information 13 Starting to Copy Files nnn nnn nn nnn nena na nnn nennen nennen nmm 13 Installation Finished 14 Chapter 4 Startup and Shutdown of NView iEMS 15 Starting NView iEMS system 15 Start LicenseManager Server 15 Starting the Nview iEMS server rennen enne rene nnn nnn nn nnn nnn nnn nnn nnn nenne nnn nnn 16 Starting the NView IEMS Client 2 72 7229 2 2 2 n nnn nnn nnn nnn nnn nnn nnn ene 17 Shutdown the NView IEMS system 18 Close the NView iEMS Client 18 Shutdown NView iEMS
6. ShutDown this Tool Start LM Admin Stop the Server Figure 4 9 LicenseServer Icon Choose stop the server option to stop License manager service and the icon will change as following figure Figure 4 10 Icon of Stopped License Server It indicates the LicenseManager service is stopped normally Chapter 5 The Installation Steps of NView EMS Module Preparation Before the installation of EMS please make sure the following issues gt Ensure that there is an NView iEMS system installed in target host and it runs normally gt Ensure that the existing NView iEMS version is satisfied with the lowest requirement of the EMS otherwise please upgrade the NView iEMS system gt Please shutdown the NView iEMS system both the server and the client and make sure that the database server runs normally before the installation process of EMS Installation Steps In this chapter we take the RC002 EMS module for an example to describe the installation steps The steps of other kinds of EMS are almost accordant Choosing Installation Languae Put the NView EMS packages installation CD into CDROM and then execute the NView EMS installation file in the CDROM A Choose Setup Language dialog will pop up as following figure Choose Setup Language select the language for this installation from the choices below conci Figure 5 1 Choose Setup Language Select suitable language and click OK to next
7. Choose the System Domain and you can log on You are highly recommended to change the password immediately after logging on in this way the system security could be guaranteed Shutdown the NView iEMS system Close the NView iEMS Client Click the system VMExit item in the system menu or the close button X on the top right corner of the main window to exit the NView 1EMS client The dialog will pop up as following figure Contirm CO Do you want to exit the client Figure 4 7 Dialog of Closing Client Click lt Yes gt to close the client Shutdown NView iEMS Server Double click the NView iEMS server stop shortcut on the desktop to stop the server and then a dialog pops up to ask for the user verification as following figure Stop Server Please input vaur Username and password Motice only user who belongs to the admin group could shutdown the servert User Name administrator Password OK Cancel Figure 4 6 Verification Dialog to Stop NView iEMS Server After entering the valid username and the password belongs to admin user groups about user groups please refer to system security in the NView iEMS User Manual and click OK the 1EMS server will shutdown automatically Shutdown LicenseManager After the successful startup of the LicenseManager the LicenseServer icon will displayed in the system tray Right click this icon and a menu will pop up as following figure
8. Deployment Mode 5 Selecting the Installation Path 6 Selecting Program Folder 8 Confirming the System Environment 8 Confirming the Installation Information 8 Starting to Copy Files ee na nnn nennen 9 Registering the Database Service 10 Installation Finished 10 Chapter 3 Upgrade steps of NView iEMS 11 Choosing the Language 11 Extracting the Compressed Installation Files 11 License Agreement 12
9. Evaluatian License Commercial License Technical support Flease read the following license carefully before either i completing the electronic order or download of the Licensed Software from an authorized website or Il installing the Licensed software from media that was delivered after being ordered by alternative order process as Do you accept all the terms of the preceding License Agreement Ifyou choose No the setup will close To install WYiew IEMS V2 0 you must accept this agreement Mo Figure 2 4 License Agreement The License Agreement of Raisecom NView iEMS system is described in this page please read it carefully If you accept the agreement please click lt Yes gt Then the system will enter the next Step If you do not accept all or parts of the terms please click lt No gt to quit the installation Selecting the Installation Mode Choose installation mode Install New IEMS Made Install New IEMS W20 Version AMiew IEMS Upgrade Upgrade pour MView EMS system from existing V1 7 version to V2 0 Installshield Back Hent gt Cancel Figure 2 5 Choose Installation Mode To deploy a whole iEMS system please choose the first installation mode that is to say Install NView iEMS V2 0 Version then next Choosing Deployment Mode N iew IEMS V2 0 Setup Options Flease choose the setup option Typical Recommended This will install client server database Cl
10. Figure 2 13 Copy Program Installation program will copy the NView iEMS program to the local hard disk If you want to quit this installation please click cancel button Registering the Database Service When the copy finished system will register database service to windows system service automatically then start the database service and initialize it Installation Finished NView IEMS 2 0 InstallShield Wizard Complete ot amp setup has finished installing NWYview IEMS V2 0 on your computer Figure 2 14 Installation finished Click lt Finish gt to complete the installation After the installation there will be three shortcut icons created on the desktop Icon for starting and stopping the server H i 3 Icon for starting the client There will be a start up shortcut in the program menu as following figure Em Raisecom MVievi iL d Client A LicenseManager Server p Bil Uninstall View iEMS sou winmysgladmin Figure 2 15 Shortcut in the Start Menu Chapter 3 Upgrade steps of NView iEMS Choosing the Language Put the NView iEMS V2 0 installation CD into CDROM Then execute the NView 1EMS V2 0 installation file in the CDROM Firstly a Choose Setup Language dialog pops up as following figure Choose Setup Language select the lanquage for this installation from the choices below oem Figure3 1 Choose Setup Language After choosing language click OK to next s
11. Section 7 4 After the uninstalling please restart HP OpenView NNM to come back the previous configurations Appendix A FAQ I What should I do if there is unwanted my ini file in windows system Answer Below Methods can be taken Method 1 If there has been a mysql database server in your computer please save the important data and then uninstall mysql database Restart the computer and then you are able to install the NView iEMS system gt Method 2 If the database server has been uninstalled and the my ini file is no longer useful please delete my int file manually and then you are able to install the NView 1EMS system gt Method 3 Install the NView iEMS system in another computer 2 What should I do if the database file 1s modified and the Server can not start Answer After installing some software the my ini file in the windows root directory will be modified or removed by force Change the my ini file in the windows root directory The following template will rewrite or create my ini The below path indicates the actual installation directory mysqld basedir C RAISECOM N VIEW IEMS Mysql datadir C RAISECOM NVIEW iEMS Mysql data WinMySQLadmin Server C RAISECOM N VIEW IEMS Mysql bin mysqld nt exe Please restart the computer after the modification 3 How to stop the SNMP Trap receiving service of Windows Answer Use the service management tools in the control panel to stop the original SNMP TRAP
12. Server 18 Shutdown LicenseManaget 18 Chapter 5 The Installation Steps of NView EMS Module 20 Preparation 20 Installation StepS 20 Choosing Installation Languae 20 Extracting the Compressed Installation Files 20 License AgreeMent n n ne nnn nn nen nnn nen nnn nnn nnn nn nnn nn emen eee ie ee eea aaia 22 Confirming the Installation Information 23 Starting to Copy Files 24 Installation Finished 24 C
13. U S registered trademark of Microsoft Corporation Windows NT is a U S registered trademark of Microsoft Corporation Windows 2000 is a U S registered trademark of Microsoft Corporation Windows XP is a U S registered trademark of Microsoft Corporation Windows and MS Windows are U S registered trademarks of Microsoft Corporation Contact Information Technical Assistance Center The Raisecom TAC is available to all customers who need technical assistance with a Raisecom product technology or solution You can communicate with us through the following methods Add 1120 Haitai Tower 229 Fourth North Loop Middle Road Haidian District Beijing 100083 Tel 86 10 82884499 Ext 878 International Department Fax 86 10 82885200 86 10 82884411 World Wide Web Feedback You can access the most current Raisecom product information on the World Wide Web at the following URL http www raisecom com Comments and questions about how the NView 1EMS system software works are welcomed Please review the FAQ in the related manual and if your question is not covered send email by using the following web page http www raisecom com en xcontactus contactus htm If you have comments on the NView iEMS specification instead of the web page above please send comments to export raisecom com We hope to hear from you WWW raisecom com Installation and Deployment Manual CONTENTS Chapter 1 Preparation fo
14. accept all the terms ofthe preceding License Agreement Ifyou choose No the setup will clase To install Wview IEMS V2 0 you must accept this agreement Mo Figure 3 4 License Agreement The License Agreement of Raisecom NView iEMS system is described in this page please read it carefully If you accept the agreement please click lt Yes gt Then the system will enter the next Step If you do not accept all or parts of the terms please click lt No gt to quit the installation Choosing Installation Mode NView IEMS 2 0 Choose installation mode Install New IEMS Made Install New EMS W20 Version HVvigew EMS Upgrade Upgrade pour MView EMS system from esisting V1 7 version to V2 0 InstallShield Back Herts Cancel Figure3 5 Choose Installation Mode Please Choose NView iEMS upgrade option then to next step Confirming the Installation Information NView IEMS V2 0 otart Copying Files Review installing component settings before copying files Flease checked you choice to install component is Current Settings setup Director CARAISECOMUNVIEW The installation components include Nview IEMS SP Back Cancel Figure 3 6 Installation Content After affirming the installation content click next to start to copy files Starting to Copy Files As the following figure NView IEMS V2 0 Setup Status NMview IEMS v2 Setup is perfarming the requested ap
15. been installed correctly This chapter will take the RC002 EMS as an example The launching steps of other kinds of EMS are almost same Operation Steps Startup NView iEMS System Please refer to Section 4 1 Adding Device Node in the Device List When user want to manage a device after logging on the client a node of this device must be created in Device List Steps are as follows gt In the Device List pane of the NView iEMS client right click the blank space of the panel and choose the Add Device item in the menu list or click the L3 button in the device list tool bar an Edit dialog will pop up The dialog contains three sub pages Basic Info SNMP Info and Properties gt Basic information page is shown in the following figure Basic Info SNMP Info Extended Properties Device Mame RCO02 Device Group Name a Current Domain Default Description Vendor Raisecom Device Type RCOO co enn Figure6 1 Basic Information In this page below items need to be configured Device Name It is required and will be shown in Device List Description It is optional and used to add some information of the node This information will not be shown in Device List Owner Group It indicates the subnet which the node belongs to The default is the root subnet Vendor Please select Raisecom if the device to be managed is produced by Raisecom Technology Co Ltd Device Type A
16. is located in Start Program HP OpenView Network Node Manager Admin NNM Services Start Then a dialog box will pop up as follow EM AA Services Shart haxc FID State Lart Beasseame 5 ocvraquestd oq PUNHINIGC Initialisaria n complete ame pardbechsch TE FOR TAG Cenmeeted to samgbeddse database prepad Leh PITHING Initialization complets LH Gerver 76 ROWING LEE Berrer eo ME A ce Be LP NA Ax ny I a oR hp openvieu process manager Attempt to start HP OpenVier servicer is completes El j Besraces Le jpEme me Figure 6 2 HP OpenView Service Management In this dialog box the service state of LM_Server and 1EMS Server is RUNNING which means that the License server and the iEMS server in the NView iEMS system is started successfully by the HP OpenView NNM If the state is not RUNNING please select the LM Server and 1EMS Server then click Restart button to start this two services Notice that LM Server must be started before IEMS Server And in the same step you can stop the NView iEMS service by the Stop button Besides the HP OpenView NNM Service Management the ovstart and ovstop commands provided by HP OpenView NNM can also be used to start and stop the NView 1EMS server For detail please refer to the user manual of HP OpenView NNM Installing NView Series EMS in Integration Mode Before the installation of EMS in the integration mode please shutdown NView iEMS server at first For t
17. needed to be started before starting NView iEMS Click Start Programs Raisecom NView LicenseManager Start License Server in windows start menu to start the LicenseManager If succeed the following dialog will pop up License Server starts successtully Figure 4 1 Start LicenseManager It needs to be informed is that the license files need to be checked during the startup process of the License Server When users firstly start the License Admin or the License Server program it is necessary to import the valid License file into the system otherwise the program cannot startup There will be an automatic prompt of whether to import a license as following figure Confirm Failed ta load license xml please import your license file Ye S Mo Figure 4 2 Prompt of Import License File Click lt Yes gt and a window for choosing the License file will appear as following figure Dpp pepp L DDI aeae ae e t DO CJ My Documents d My Computer CJ Mv Network Places 5 license xml File Marne license xml Files af Type XML Files cxml w ERE RETE Figure 4 3 Importing license file Select the License file XML style which have been authorized and click the Import button then the License file will be checked and imported automatically into the system If succeed the license server will start normally If fail maybe there are errors as following The License is trial and exceeds the time li
18. EMS after version V1 X The NView iEMS V2 0 includes all functions of VI X and makes some improvements to enhance its flexibility The NView iEMS V2 0 installation program can both deploy a complete NView iEMS system and upgrade NView iEMS V1 X to V2 0 And the data and EMS of former V1 X can be reserved The installation and deployment mode of NView 1EMS V2 o which is described in chapter 2 fits for users who use the NView 1EMS at the first time As for the users who have used the NView IEMS V1 X can directly refer to chapter 3 which describes how to upgrade the V1 X system to V2 0 Operation Environment Environment Requirements of Hardware To deploy complete NView iEMS V2 0 system different installation modes have different requirements to hardware as following table Table 1 1 Hardware requirements of system CPU Frequency Hard Disk Client installation P4 1GHz 512M 500M Typical installation P4 2GHz Environment Requirements of Software NView iEMS system has its own complete running environment so it is enough if the requirements of operation system are satisfied At present the NView iEMS system supports the following operation system Windows 2000 series Windows 2003 series gt Windows XP series Confirming the Operation Environment Before installing the NView 1EMS program please make sure below requirements Ensure that there is no other network management product of NView series installed in target host
19. If there is please uninstall it firstly But if there is an NView 1iEMS V1 X installed in target host please upgrade it to V2 0 via this installation program For detail steps please refer to chapter 3 gt Ensure that there is no MySQL database installed in target host if there is please uninstall it gt If there is network security software installed in target host for example Norton Internet www raisecom com Installation and Deployment Manual Security to make sure the installation performed normally please shutdown the network security software during the installation process Otherwise there may be system running error caused by database initialization operation failure Ensure that the SNMP Trap receiving service of Windows operation system in target host has been stopped NOTE During system deployment it is extremely forbidden that there is another SNMP network management system in the computer in which iEMS server has been installed Otherwise there may be system running errors caused by resource occupation and other reasons The most typical example is that the system can not receive traps because that the port 162 has been occupied Choosing the Deployment Mode At present the NView iEMS program has two kinds of deployment modes gt Typical deployment mode Typical deployment mode means installing the client server and database in a same computer This deployment mode is applied to the centralization of admini
20. RA SECOM www raisecom com N View IEMS V2 0 Installation and Deployment Manual RC A012 V20 060303 EN Legal Notices Warranty Raisecom Technology Co Ltd makes no warranty of any kind with regard to this manual including but not limited to the implied warranties of merchantability and fitness for a particular purpose Raisecom Technology Co Ltd shall not be held liable for errors contained herein or direct indirect special incidental or consequential damages in connection with the furnishing performance or use of this material A copy of the specific warranty terms applicable to your Raisecom product and replacement parts can be obtained from Service Office Restricted Rights Legend All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of Raisecom Technology Co Ltd The information contained in this document is subject to change without notice Copyright Notices Copyright 2006 Raisecom All rights reserved No part of this publication may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in Writing from Raisecom Technology Co Ltd Trademark Notices RA SECOM is the trademark of Raisecom Technology Co Ltd Java is a U S trademark of Sun Microsystems Inc Microsoft is a
21. e of Nview iEMS system after installation And the importation step is different with that of Standard Edition It needs to copy the license file directly to iEMS installation path LicenseManager LicenseManager The file name must be License xml if not please change it The LicenseManager can identify and import it automatically NOTE If the license file is not copied to assigned path during the installation process the process management service PMD of HP OpenView NNM will inform to import license file when it startup the Nview iEMS system After importation of the license file it is sure that the license server will run normally but dialog will pop up to inform that the it is fail to start the Nview iEMS server which is not approved by license server during the startup process Please start the Nview iEMS server according to the Section 8 3 Launching the NView 1EMS Server in HP OpenView NNM After the integration of NView iEMS and HP OpenView NNM system the License server and iEMS server of NView 1EMS system are relegated to PMD Process Management Daemon of HP OpenView NNM for administration Normally after the startup of HP OpenView NNM the License server and 1EMS server will start together So in the integration mode it is enough only to make sure that the HP OpenView NNM server runs normally Manual Startup of License server and IEMS server is unnecessary Start the HP OpenView NNM service via the Windows starting menu the item
22. e read the following license agreement carefully Fress the PAGE DOWN key to see the rest of the agreement This License Agreement details the policy far license of Raisecam NView Licensed Software on the following topics Evaluation License Commercial License Technical support Please read the following license carefully before either i completing the electronic order or download of the Licensed Software from an authorized website or i installing the Licensed Software from media that was delivered after being ordered by alternative order process as Do you accept all the terms of the preceding License Agreement Ifyou choose No the setup will clase To install ACIQ Element Management you must accept this agreement No Figure5 7 License Agreement The License Agreement of Raisecom NView EMS module is described in this page please read it carefully If you accept the above agreement please click Yes Then the system will enter the next Step If you do not accept some or all of it please click No to quit the installation Confirming the Installation Information RCOO Element Management start Copying Files Review settings before copying files Please recheck it and the components you have selected are Current settings setup Directory CARAISECONnNBNSIES setup Component ROO Element Management Back Cancel Figure5 9 Confirm the Installation Content After confirming the in
23. e server the dialog box about the failure of connecting to the database as follow appears Failed to initialize Database Connection Pool Figure9 4 Dialog Box of Prompt Answer gt Check whether the Fire Wall forbids the connection of mysql or not If yes close the Fire Wall or configure it to permit the connection of mysql gt Check whether the mysql server starts normally or not If the mysql icon on the windows tray is green it is normal If the icon is red it is abnormal If it 1s abnormal please check the configurations of the mysql server and restart the service gt If the mysql service starts normally check whether the 1EMS data is correct If there is not any file in the Installation path mysql data iEMS path two methods are presented Methodl Reinstall the NView iEMS system Method2 Create the NView iEMS database gt If in the installation path iEMS mysql bin directory there is a insertdata bat file double click the file and then the NView 1EMS database can be created Open a windows console change to Sinstallation pathiEMS mysql bin directory execute mysql uroot praisecom lt iemsEN sql command and then the NView 1EMS database can be created 6 What should I do if I cannot receive the trap message from the equipment To ensure that every trap message could be receive and displayed correctly by the system the following requirements must be meet gt All the network equi
24. em at first gt The installation program checks whether the version of NView iEMS system which has been installed in local computer matched that of EMS If the NView iEMS version is lower than the requirement of EMS the installation system will give a prompt Severe LLL x e The current MView platform version is lower than required Far installing EMS package please upgrade Myiew iEMS platform First Figure5 5 Dialog Box of Prompt After clicking lt OK gt the installation program will exit Then please install the latest Service Pack of NView iEMS system before the installation of EMS gt The installation program will check whether the version of EMS is lower than the one of the same type EMS installed in local computer If there has been an EMS module of the same type installed in the computer and the version is higher than the one you will install the system will give a prompt Severe e The version of the EMS package you are installing is lower then the one you have installed the setup process will be terminated Figure5 6 Dialog Box of Prompt After clicking OK the installation program will exit However if the version of the EMS module which has been already installed is lower than or same as the one you will install the installation will continue without any prompt and after the installation the EMS module will be upgraded License Agreement RCOO Element Management License Agreement Fleas
25. erations Installing CARAISECOMINVIEMWAIEMS cient lin Alarm Statistic jar 8375 Cancel Figure 3 7 Copy Installation Program Installation program will copy the NView iEMS program to the local hard disk If you want to quit this installation please click lt cancel gt button Installation Finished NView IEMS V2 0 InstallShield Wizard Complete dom amp setup has finished installing N iew IEMS 2 0 on your Computer Figure 3 8 Installation Finished Click Finish to complete the installation through which 1EMS V1 X system has been upgraded to V2 0 smoothly All the existing data configuration information and installed EMS will still exist as before and have no changes Notice This upgrade function only aims to the 1EMS V1 X which installed in Typical mode As to the clients installed by Distributed mode please uninstall them and then perform NView iEMS V2 0 to install new clients Pay attention after the installation of new clients please install EMS Chapter 4 Startup and Shutdown of NView iEMS Starting NView 1EMS system Before starting NView iEMS system please ensure that the MySQL service runs normally Open the system services list windows by Control panel Management tool Service path and then check the status of MySQL is Started or not If not please start it firstly Start LicenseManager Server LicenseManager is provided to check the validity of the 1EMS program and
26. fter selecting a vendor all types of devices produced by the vendor will be listed here Please choose a device type which you need SNMP information page includes the management information about the equipment as following figure Basic info SNMP Info Extended Properties IP Address 192 168 1 252 SNMP Basic Entf SNMP Version GMlFP v7 SMMP Part 161 Read Community public Write Community private Timeoutis Retry Times ox cae Figure6 2 SNMP Information Below items need to be configured in this page as follows IP address It indicates the IP address of this device As to SNMP network management device it means IP address of the SNMP Agent SNMP Basic It indicates SNMP management parameters which include SNMP version SNMP port Read Write community Timeout configuration and Retry Times All of them are necessary and have default value When SNMP version is set to SNMP V3 the SNMP V3 Tab will be configurable This tab includes User Name Security Level Authority Protocol Privacy Protocol Authority Password and Privacy Password NOTE The SNMP read write community must have the same setting as the Agent or else the operation of the management configuration will fail gt Extended Properties page is shown as following figure Basic Info SNMP Info Extended Properties Mame isIF isSNMP isRouter is Switch isHTTFSerice isFTPSarvice isTelnetService isRaisecam TypeMNO
27. g Right click this icon and a menu will pop up as following figure ShutDown this Tool Start the Server Stop the Server Figure4 5 Server Icon The commands included in the menu is as follows ShutDown this Tool Only close the tray icon no operation of the server gt Startthe Server Execute this command to start the NView iEMS server Stopthe Server Execute this command to close the NView iEMS server Starting the NView iEMS Client After the NView 1EMS server is started and runs normally please start the client by double clicking the client shortcut on the desktop Then a logon dialog appears as following figure 1 2006 03 1416 48 57 Initializing Look and Feels 2 2008 03 14 16 48 57 Initializing Server Connection 3 2008 03 14 16 48 57 User Login 666600 A Please inputthe user name and password license xml User Name administrator td Mozilla FireFox Password r 1 Domain System Domain A P di Internet OK Cancel Explorer 20K Cancel Figure4 6 iEMS Client Log On Enter the correct username password and management domain About domain please refer to system security in the NView iEMS User Manual and click OK then the boot manager will execute the remaining starting tasks Finally the main application window will display and the startup of the client is successful NOTE In default the username is administrator and the default password is raisecom
28. hapter 6 Launching the EMS 26 Basic Steps oene nennen nnn a manna na nennen E E 26 Operation Steps enema nena nena nan nenne nennen emen nnnm meme 26 Startup NView IEMS System 26 Adding Device Node in the Device List 7 7 mmm mmm 26 Launching the EMS 28 Chapter 7 Uninstalling the NView iEMS 30 XS ORR o a 30 WWwW raisecom com Installation and Deployment Manual Shutdown Nviwe IEMS System on onn nnnm nennen nnnm nemen 30 Shtaowrbbicernselysnddge sseeeeeeedicieteentuit eiue ee iedeue ager rece ae cie pets 30 DIOP ang REMOVE MY SQL Seryer sereen t eer ueteres erc uude euet qoM dnce 30 Uninstall NView IEMS nnnm nnne mene nnnm nennen nnne mememmm mmm 30 Chapter8 The Integration of Nview iEMS and HP OpenView NNM 32 The Preparation before Installation
29. he steps of stopping NView iEMS server in HP OpenView NNM please refer to Section 8 3 The EMS installation steps of NView series in the integration mode are familiar with the steps in standard mode The simple special step of the fist one is that there will be a check during the last installation step If the check result is that the NView 1EMS system has already integrated in HP OpenView the EMS will be integrated in HP OpenView NNM automatically and then a Information dialog will pop up Figure 8 3 HP OpenView NNM Installation Path Click OK the installation program will complete the subsequent work Please start the NView 1EMS server For the startup descriptions please refer to Section 8 3 after the installation Launching the Application Component of NView 1EMS in HP OpenView NNM After the integration installation there will be a Raisecom NView menu in the menu bar of main operation view in HP OpenView NNM This menu includes all the Niew 1EMS application components and the corresponding startup menu as following figure biting eru B T4 Trap tei AM Te EO dimi a8 Figure 8 4 HP OpenView NNM Main Menu after the Integration Click the menu option to launch corresponding application component The current alarm monitor module will be taken as an example as following figure A ar mud e oe Lied oe ier E Figure 8 5 Start Alarm Monitor Module in HP OpenView NNM For security logging on
30. he startup manager will execute the rest of the task and finally launch the main view of the Device List component as following figure PF d hh WX TENTI Figure 6 6 Device List Component in HP OpenView NNM After opening the Device List the corresponding operation can be performed e g adding device node launching EMS and etc Launching the Nview Series EMS in HP OpenView NNM There are two ways to launch the EMS for equipment configuration and management in HP OpenView NNM system gt Launch Device List component of Nview iEMS in HP OpenView NNM please refer to Section 8 6 and then add device node and Launch the EMS in the Device List gt Add device node in the topo of HP OpenView NNM and then launch the EMS directly NOTE Only adding a node of a device in the topo of HP OpenView NNM ts not enough to launch EMS and adding a node of this device in Device List of Nview iEMS is necessary That is to say a same node must exist both in HP OpenView NNM and Nview iEMS so that the corresponding EMS can be launched For first launching method please refer to Chapter 6 Here it will mainly introduce the process of adding node and launching EMS in HP OpenView NNM topo Add node after the startup of HP OpenView NNM The operation item is located in Menu edit AddObject Palette The system will open the dialog box of AddObject Palette choose the Raisecom item in the Symbol Classes and choose the equipment
31. ick Next To install to a different tolder click Browse and select another folder Destination Folder Ci RaisecomsN Seve Browse Back Cancel Figure 2 8 Choose Destination Location The default work path for installing NViewiEMS system is C Raisecom N View Using Browse you can select other installation path After pointing the installation position click next to enter the next Step In this step the installation program will check the current operation system automatically to make sure whether there is a MySQL database installed If so there will be following notice Information Bc 7g X a i r1 COMIN has already existed the setup process will be terminated Ta contuinue with the installation please delete Ehe my ini File or refer to Ehe user manual Figure 2 9 MySQL Prompt If the installation program finds out that there is my ini file my ini file is the system configuration file of MySQL database a message dialog box will pop up which informs the user that there is a my ini file and the position of this file Therefore the installation is terminated after pressing the lt OK gt button When this problem occurs the following methods are available gt Method 1 If there has been a mysql database server in your computer please save the important data and then uninstall mysql database Restart the computer and then you are able to install the NView iEMS system without this prom
32. ient Orly This wall install client only Figure 2 6 Choose Deployment Mode In this Step different deployment modes can be chosen according to user s requirements include gt Typical mode Users are able to install the NView iEMS client server database and LicenseManager in the same computer This option is recommended Click this button to enter next step directly gt Standalone Client mode Standalone Client mode only installs the Client of NView iEMS system in the computer As a result you need to enter the next Step to fill in the IP address of the computer in which the NView iEMS server has been installed and then users are able to access the NView iEMS server through the specified server IP Click this button to Config server IP address step as following figure Please select the IP address of the host where MView EMS platform server will be installed default 127 0 0 1 indicates local PL ServerlP InstallShield Back Cancel Figure 2 7 Config Server IP Address Enter the NView 1EMS server IP address through which clients can access the server Then Click next to enter the Selecting the installation path Step selecting the Installation Path Enter the installation path Steps as follows NView IEMS V2 0 Choose Destination Location select folder where Setup will install files setup will install WYyiew IEMS V2 0 in the following folder To install to this folder cl
33. is needed for launching application component in the integration mode After entering the correct username and password the launching management will execute the subsequent tasks and then launch the main operation view of current alarm management as following figure E ail E Aeeosarg eee H 7 ae pe ENGEL wm LIJILLIJ Bae BW ds EA m d dcs HM uL ES is Lied i T Gai sES PIT LXI A miima Famam um mam smmm erum F Figure 8 6 Launch Alarm Monitor Module in HP OpenView NNM After opening the current alarm monitor window you can perform the corresponding operations These operations are familiar with that in NView iEMS SE SE Standard Edition The launching processes are just same as the preceding steps Launching Device List in HP OpenView NNM Among all the integrated application components the Device List component is special Its function is similar to the mid bridge i e the registering of device node in the HP OpenView NNM is not enough to launch the corresponding EMS Registering in the Device List component is necessary After the successful integration there will be a Raisecom NView menu appears in the menu bar of the HP OpenView NNM main application view Click the Device List item to launch the Device List component as following figure Figure 8 7 Launching Device List in HP OpenView NNM Enter the right username password and the management domain then t
34. ke sure that the NView iEMS server has been started and it can access the network normally The port 9314 and 9312 can provide service correctly If the NView iEMS server has started please check whether the client computer can communicate with the server computer If the two computers can communicate with each other the problem may be caused by the IP modification of the NView iEMS server or the server IP has not entered correctly during the installation of client You can modify the file which locates at iEMS installation directory Client config SystemService xml in client computer Change the value in IPAddress to the IP address of server computer 8 After adding device node in the Device List when opening the EMS there is prompt about the equipment communication overtime or there is no equipment view in the EMS Why Answer The error may be caused by the following reasons Y VVVV Confirm that the Agent module works normally It means its SYS indicator and Ethernet port indicator should be in normal status The Agent module must be put into the correct slot For RC002 and RCO04 the right slot for Agent module is the first one in chassis Ping the IP address of the equipment to check the communication Confirm that the EMS version is consistent with the version of the Agent software Check whether the Device Type of node is same as the actual device type Confirm that the SNMP information read write community
35. l Bb 2chassis e noe amp EEE EN SSES Pe 4Module E oleleleleleleoelelelelelelele Pe 5Module Pe Module Pe Module 0 1 5 7 8 9 10 1 12 13 je 8Module T 10Module e 11Module Pee 12Module T 13Module Pe 1 4Module T 15Module PS1 Current Device 192 168 1 252 D Client online Raisecom Co Ltd Figure6 5 RCO02 EMS NOTE Only after the correct installation of EMS the Management item can be listed in right click menu or the configuration and management of device will be unavailable Chapter 7 Uninstalling the NView iEMS Basic Steps Shutdown the Nview 1EMS system including server and client Shutdown LicenseManager Stop and remove MySQL server gt gt Uninstall Nview 1EMS system Shutdown Nviwe iEMS System Please refer to Section 4 2 Shutdown LicenseManaager Please refer to Section 4 3 Stop and Remove MySQL server Open the database admin console in the Windows start menu The item is located in Start Program Raisecom N View iEMS winmysqladmin shown as following figure km Raisecom MMiew fa EMS a Client LicenseManager Server d fall Uninstall NView iEMS SOL winmysgladmin Figure7 1 Database Start Menu And then an icon of the database console will appear in the windows tray If the database service runs normally the icon will light in green Right click this database console icon a menu will pop up as following figure ShutDown this Tool Figure7 2 Da
36. mit License file is destroyed or the contents in it are not correct License file is modified manually The IP address of NView iEMS system is different from the defined content in the License file VVVV All of the above errors may cause the import failure and the NView iEMS system can not start normally Please contact with Raisecom for technology support if you meet above errors Starting the Nview iEMS server After starting the License server successfully the server of NView iEMS can be started Double click the shortcut of start the server on desktop to start the server as following figure Fi NView Server Raisecom Technology Co Ltd 2005 03 14 16 46 42 Initializing Log Manager 2006 03 14 16 46 42 Initializing Database Connec 2005 03 14 16 46 43 Connecting License Server 2005 03 14 16 46 43 Initializing Command Service 2005 03 14 16 46 44 Initializing Event Service 2005 03 14 16 46 45 Initializing Internal Channel 2006 03 14 15 45 45 Initializing Schedule Job Server starts successfully ozilla FireFox Figure4 4 iEMS Server Start Successfully After the successful startup the NView iEMS server will run as the background service process Meanwhile the IEMS server icon will be displayed in the system Tray The periodically flicking of this icon means that the server is running normally If there is no flicking it means that the server has already stopped runnin
37. node that need to be established in Symbol Subclasses for Class Raisecom The choosing process is shown as following figure taking RC002 device for a example Add Object Palette Xl Symbol Classes b Raisecom Server Senacel symbol Subclasses for Class Raisecom B RCOO 3 Drag a Subclass Symbol to the desired Submap Close Help __tas__ Figure 8 9 Icon Choosing Process Select the Icon of RC002 and pull it to the HP OpenView NNM topo and then configure its properties such as IP address for management If a correct installation of RC002 EMS has been performed before right click this node a Launch RC002 EMS option will appear in menu list as following figure Symbol 192 1568 1 254 Oper Change Symbol Type Symbol Properties Delete Hide Object Properties Launch RCOO2 EMS Figure 8 10 Right click Menu in HP OpenView NNM Click Launch RC002 EMS option to launch the EMS Uninstalling the NView 1EMS System in the Integration Mode The uninstalling process of NView 1EMS in the integration mode is same as the ones in Standard Edition It has three steps as follows gt Shutdown the NView iEMS server close all the application component and EMS windows and then stop the License and server service of NView iEMS For details please refer to Section 8 3 gt Stop the database service refer to Section 7 3 Uninstall the NView iEMS system refer to
38. nstallation CD into CDROM then execute the NView 1EMS V2 0 installation file in the CDROM Firstly a Choose Setup Language dialog pops up as following figure Choose Setup Language select the language for this installation from the choices below cancel Figure2 1 Choose Setup Language After choosing language click OK to next step Extracting the Compressed Installation Files The installation program is extracting and copying installation files automatically as following figure HAm SECOM Vision Creates Future 5 i 2006 Installshield Wizard NView IEMS V2 0 Standard Setup is preparing the InstallShield Wizard which will quide you through the rest of the setup process Please wait Cancel Figure 2 2 Extracting Files When copy finished the welcome page will be displayed as following figure NView IEMS V2 0 Welcome to use N yTew IEMS V I installation Itis strongly recommended that you exit all Windows programs before running this Setup program Click Next to continue with the Setup program Figure 2 3 Welcome Page Click lt next gt to enter next step License Agreement NView IEMS V2 0 License Agreement Please read the following license agreement carefully Press the PAGE DOWN key to see the rest of the agreement This License Agreement details the policy for license of Raisecom Nview NNM Licensed software on the following topics
39. pment being managed and the management workstation where the iEMS system located must be connected to the network correctly Please ensure that the links to one another is unblocked being able to ping through to one another and permitting the communication of UDP protocol gt The 162 port of the host where the iEMS system server is located could not be occupied For example in the Win2000 Server operation system it will start up the SNMP Trap service by default Y Vv WV WV gt This service will occupy the 162 protocol so before installing the 1EMS in the operation system you need to stop this service and release the port otherwise 1EMS could not receive the warning message Attention only the host computer here the 1EMS system server is located need to meet the requirement In the case of distributing system installation there is no such requirement for the host computer which client is located in The network must permit UDP protocol transmission In some specific application environment for the consideration of safety all the network equipment is hidden behind a Fire Wall In this case you must ensure that the Trap could go through the Fire Wall and reach the management workstation otherwise the system cannot receive the warning message either The network equipment agent must set the correct trap target address which is the IP address of the host computer where the iEMS system server is located in In the 1EMS system there m
40. pt Method 2 If the database system has been uninstalled but my ini file was not deleted please delete my ini file manually according to the position of my ini file informed in above information dialog And then you are able to install the NView iEMS system without this prompt Method 3 Using another computer to install the NView 1EMS system Selecting Program Folder NView IEMS V2 0 Select Program Folder Flease select a program folder setup will add program icons to the Program Folder listed below ou may type a new folder name or select one fram the existing folders list Click Next to continue Program Folders Existing Folders Accessores Administrative Tools EMS MySQL Manager Games Mozilla Firefox startup symantec Client Security WinRAR Back Cancel Figure 2 10 Selecte Program Folder This program folder is in the Windows Start menu The default is NView iEMS Standard and can be changed by user Click lt next gt to enter the next Step Confirming the System Environment NView IEMS V2 0 Contirming the Operation Environment please check the operation environments config Before installing the program please confirm the current system s environment Current settings Please confirm that current system s environment has configured correctly 1 Please confirm thatthe TCP IP protocol in the system is configured correctly 2 Flease confirm that there is no mysql database or mysql se
41. r Installing NView IEMS V2 0 1 eM 1 Operation Environment 1 Environment Requirements of Hardware 1 Environment Requirements of Software 1 Confirming the Operation Environment 1 Choosing the Deployment Mode 2 Installation StepS 2 Chapter2 Installation Steps of NView iEMS V2 0 3 Choosing the Language 3 Extracting the Compressed Installation Files 3 License Agreement nnn a na nnn na nna na nana nnnm n ememeTmMMMM 4 selecting the Installation Mode 5 Choosing
42. registered in the equipment node is consistent with the setting of the Agent The default read write community is public and private Readjust SNMP TimeOut parameters and Retry parameters according to the network status Fr mand NON ON ON N NON NN NN NN NN NN N
43. rted Started Started SNMP Trap Service Properties Local Computer General Log On Recovery Dependencies Service name Display name Description Path to executable SMMPTARAP SNMP Trap Service Receives trap messages generated by local ar remote Disabled Automatic Automatic Automatic Automatic Manual Manual Automatic automatic Automatic Manual Manual Automatic Automatic Automatic Automatic Subornatic Manual Manual Manual A x CAWINNT S ystem3z snmptrap exe Startup type Service status Started lors E bart Stop Pau Resume ou can specify the start parameters that apply when vou start the service fram here Start parameters coed ts lol x Figure9 2 SNMP Trap Services Properties Dialog gt Change the Startup type to Manual and click the Stop button below then the service will stop Click OK button to apply the changes 4 What should I do if the connection to License Server is failure when starting the NView iEMS server When starting the NView 1EMS there is a dialog pops out as following figure Cannot connect to licenze server please startup it first Figure 9 3 Fail to Connect License Server Answer The reason is the License Server is not started successfully Please refer to Section 4 1 4 for detail This error will not pops up after a success startup of License Server 5 When starting th
44. rvice in this computer 3 Please confirm that there is no other network management systems or any other trap recelver programs that occupy the 152 port for example the SNMP Trap receiving service in the operating system and so on q f there is personal Fire Wall running on the host please shutdown the personal Fire Wall in this computer during the installation Figure 2 11 Confirm Operation Environment User should confirm the current system environment before installing NView 1EMS V2 0 system Then click lt next gt to enter next step Confirming the Installation Information In this page all installation options which user has selected are listed After affirming the installation content click lt next gt to start to copy files Start Copying Files Review installing component settings before copying Files Please check the component that you choose to install Curent Settings Setup Directory Haizecom MN Views The installation components include HVview EMS Client HVigw IEMS Server Javal 5 0 Database InstallShield Cancel Starting to Copy Files Start Copying Files Review installing component settings before copying Files Please check the component that you choose to install Curent Settings Setup Directory SHaizecom MN Views The installation components include M iew EMS Client HVigw IEMS Server Javal 5 0 Database n InstallShield Cancel
45. stallation contents click next to start copying files Starting to Copy Files RCOO Element Management Setup Status RCO Element Management Setup is performing the requested operations Installing CARAISECOMUNVIEMMIEMS FEMS VRCO0e yresource ican 242 44 lmported git MEE EBEN Cancal Figure5 10 Copy Installation Files This process will copy the program files of the EMS module into the local hard disk If you want to cancel this installation please click Cancel Installation Finished RCOO Element Management InstallShield Wizard Complete as amp setup has finished installing F CDD 2 Element Management on your computer Figure5 11 Installation finished Click lt Finish gt button to close the dialog NOTE If the NView iEMS system is deployed in the distributed mode it is necessary to install the EMS module in all computers which the iEMS server and all the clients are installed in Chapter 6 Launching the EMS Basic Steps To launch the EMS for equipment configuration you should go through the following steps gt Startup the NView iEMS system gt Add the device node in the Device List gt Launch the EMS for equipment configuration Before launching the EMS the following requirements must be satisfied gt Ensure that the NView iEMS system has already been installed on the computer and it is running normally gt Ensure that the EMS of the corresponding managed equipments have
46. stration and maintenance based on the management of central computer room Distributed deployment mode Distributed deployment mode is a distribution method that separates the client from the server In this mode different clients are allowed to access one same server This deployment mode meets the administrator s requirements for long distance and multi user administration To perform this deployment mode firstly you can choose the Typical installation option in the installing process to install server and database in one computer and then choose the Standalone Client option in the installing process to install clients only in other computers During the client only installation process the IP address of the server is required NOTE When upgrading the system installing service pack EMS application component which is deployed in the Distributed model both the server host and the client hosts must run these corresponding installation programs separately Installation Steps There are three steps for complete installation of the NView iEMS V2 0 system gt gt gt Firstly install the NView 1EMS V2 0 system Then install the latest service pack of NView iEMS system if necessary At last install the EMS modules according to requirements of network management e g EMS of RC002 EMS of ISCOM series switches and etc Chapter 2 Installation Steps of NView iEMS V2 0 Choosing the Language Put the NView iEMS V2 0 i
47. tabase Console Icon Click Stop the Service and Remove the Service in turn to stop and remove the MySQL service If the operations are successful the light color of the icon turns into red At last click the Shutdown this Tool to close the database console Uninstall NView 1EMS Execute the uninstalling operation in the Windows start menu The item is located in Start Program Raisecom NView iEMS Uninstall NView iEMS InstallShield Wizard Welcome Modify repair or remove the program Welcome to the NView IEMS V 1 Setup Maintenance program This program lets you modify the current installation Click one ofthe options below C Modify E select new program components to add or select currently installed components to remove Reinstall all program components installed by the previous setup Remove all installed components omen Figure7 3 Uninstall the Nview iEMS System Choose the Remove option and click Next to start uninstalling the NView iEMS After that please restart the computer Chapter 8 The Integration of Nview iEMS and HP OpenView NNM The Preparation before Installation lt Before installation please make sure that the present operation system is Windows2000 or Windows XP if not please install the related operation system and then start the installation lt Before installation please make sure that HP OpenView NNM system is already installed and functions well The
48. tep Extracting the Compressed Installation Files The installation program is extracting and copying installation files automatically as following figure BAISECOM Vision Creates Future 2006 InstallShield Wizard F3 NView IEMS V2 0 Standard Setup is preparing the InstallShield 3 Wizard which will guide you through the rest of the setup process Please wait Cancel Figure 3 2 Extract Installation Files When copy finished the welcome page will be displayed as following figure NView IEMS 2 0 Welcome to use NView IEMS v D installation Itis strongly recommended that you exit all Windows programs before running this Setup program Click Next to continue with the Setup pragram ee oom Figure 3 3 Welcome Page Click the next to enter the next step License Agreement NView IEMS V2 0 License Agreement Please read the following license agreement carefully Fress the PAGE DOWN key to see the rest of the agreement This License Agreement details the policy for license of Raisecom Nview NNM Licensed Sofware on the following topics Evaluatian License Commercial License Technical Support Flease read the following license carefully before either i completing the electronic order or download of the Licensed Software from an authorized website or il installing the Licensed Sofware from media that was delivered after being ordered by alternative order process as Do you
49. ust be a trap defination of this alarm otherwise even the trap message is received it will be considered as an unknown trap Check whether the iEMS system has set the filtration condition if it has this trap cannot be displayed or saved The equipment where the trap happens must have registered related node in the system there are related nodes in the Device List otherwise the trap will be treated as the source unknown and be discarded The related node of the equipment where the trap happens must be an equipment in the management domain where the administrator has logged on otherwise the trap message cannot be displayed It can be received but there is no display in the client where the administrator has logged on If the administrator logged on as the admin group member there is no such restriction EMS version must be corresponding to the version of the Agent program for example if version of the Agent program is higher and the EMS is lower the trap may not be received either If the above requirements are fulfilled the IEMS system can receive and analysis the trap messages normally Attention the above requirements are the minimum requirements for receiving the warning In some specific application environment other requirements may be needed 7 How to do if the client can not connect with server after the Distributed installation Answer You can solve this problem as following steps At first please ma
50. version of OpenView is V6 02 or above lt Before installation please make sure that the TCP IP protocol is configured correctly lt Before installation please make sure that there is no mysql database or mysql service in this computer lt If there is network security software installed in target host for example Norton Internet Security to make sure the installation performed normally please shutdown the network security software during the installation process Otherwise there may be system running error caused by database initialization operation failure Installing the Nview 1EMS AE The installation steps of AE are almost familiar with that of Standard Edition The special step of the former ones is that after successful registration and startup of database service a dialog will pop up It is asking whether to integrate N View iEMS with HP OpenView NNM system as following figure x M 4 2 Do you want to use NView iEMS on HP Openview Figure 8 1 Dialog of Integration Inquiry If clicking No the Nview iEMS system will not be integrated into HP OpenView NNM and the installation program will complete the installing of Nview 1EMS Standard Edition If click Yes the installation program will integrate the Nview iEMS system into HP OpenView NNM automatically After the installation please restart the HP OpenView NNM to make sure the corresponding configurations of integration are valid Please import license fil
Download Pdf Manuals
Related Search
Related Contents
EpiCompare User Guide Inscriptions 2011, mode d`emploi : École, restauration scolaire Creatr HS Materialise Manual for Mac Dustless Technologies 15505 Use and Care Manual RSUK0044 Issue 6 MTOsport Maintenance manual CDIH116IR Users Manual USER`S MANUAL - University of Nebraska Medical Center Programm Frühjahr GBD T120 1. Instalação do ESET Endpoint Security Copyright © All rights reserved.
Failed to retrieve file