Home

SBP-1100e User Manual - 1100 Energy Corporation

image

Contents

1. 6 Eleven Hundred Energy Corporation The SBP 1100e has two domed buttons for user interaction in addition to to the non domed RESET button The but tons are tactile feedback membrane switches that give the user a positive indication by feel that the button has been activated The SCROLL button allows the user to scroll though a number of options presented on the display Pressing the SCROLL button once will turn on the LCD status display and backlight for about 8 seconds Repeatedly pressing the button slowly will cycle through the display options The SELECT button enables a display of product identification information including the software version number In fu ture versions of the SBP 1100e the SELECT button will implement a menu system Pressing the SELECT button once will turn on the LCD status display and backlight for about eight seconds and display SBP 1100 V4 1 2 1100 ENERGY CORP Repeatedly pressing the SELECT button slowly does the same LCD Backlighting The LCD on the top of the SBP 1100e has backlighting which makes the display readable in the dark The backlighting turns on automatically whenever one of the buttons on the control panel is pressed The backlighting will remain on for about 8 seconds and then automatically turn off to save power unless a button is pressed again before the backlight has turned off in which case the backlight will remain on for eight s
2. 24 or 28 volts DC 4 factory Custom Output Voltages Fixed voltages from 6 to 28 volts DC 4 factory set Input Charging Voltage 10 to 28 volts DC continuous filtered or low ripple Use an approved power source Input Charging Power up to 200 watts in increments of 50 watts Energy Storage Capacity 10 hr discharge 1100 watt hours initial capacity 1000 watt hours available for output EA AM AZ 72 Amp hours 13 8 volt model 40 Amp hours 25 3 volt model Temperature Range for charging 0 to 40 C 32 deg F to 104 deg F Temperature Range for discharging 20 to 50 C 4 deg F to 122 deg F Temperature Range for storage 20 to 60 C 4 deg F to 140 deg F Max Continuous Discharge Load 25 3 volts 300 watts less than 1 hour at 25 deg C 77 deg F Poe le ZBO vais 9 volts 180 watts 6 volts 120 watts Max Continuous Discharge Load 25 3 volts 200 watts more than 1 hour at 25 deg C 77 deg F 2 38 volts L80 watts 9 volts 120 watts 6 volts 80 watts Charge discharge Cycle Life more than 400 cycles typical 20 reduced capacity after 300 discharge cycles Service Life about 5 years typical for 20 reduced capacity due to aging Batteries age faster at higher storage temperatures and at higher storage state of charge approx 28 5 Ibs Recharge time from empty 8 to 10 hours using the 130 watt SBP AC adapter SBP AC ADAPTER 24V 130W C
3. Water and oil resistant rubber jacketed cable Connection Wiring Diagram Pin Description Wire Color DC Output Red DC Output DC Output Return D__ DC output Return E _ No Connection NoConnection 5 Pin Male Output Mating Plug mating face view Serial data port The SBP 1100e has a serial data port which permits the unit to be controlled and or monitored remotely using a serial RS 232 data terminal or a computer which emulates a data terminal Contact 1100 Energy for detailed information concerning this feature Serial Data Port Connection Specifications Note Fully assembled 10 foot SBP CBL RS232 10FT or 5 foot SBP CBL RS232 5FT RS 232 Data Cables are avail able from 1100 Energy The cables will connect the SBP 1100e directly to a 9 pin serial port of a personal computer Mating Plug Model Ne SBP CON DATA Serial Data Port mating plug miniature cylindrical 5 pin female for SBP 1100e MIL C 26482 Series 1 shell size 10 plug 6 socket contacts 20 AWG MS3116F10 6S Connection Wiring Diagram Pin Signal Description Serial Data Pin Serial Data Pin 9 pin PC D Connector 9 pin Modem D Connector Data Input to SBP 3 PC to SBP TxD 2 Modem to SBP RxD B Data Out from SBP 2 SBP to PC RxD 3 SBP to Modem TxD D No Connection No Connection No Connection E _ No Connection No Connection No Connection 6 Pin Female Data Mating Plug mating face view Control panel buttons
4. formats Charging 4 5HR Dschging 3 0HR Idle Twilight mode In 23 5V 3 2A Out 13 8V 4 3A In Temptr 27C Out Temptr 43C Press the SCROLL button slowly to cycle the LCD display through the series of screens which show input and output voltages and currents and other informational displays including the temperatures of the input and output power con version modules inside the SBP 1100e At any given time the SBP 1100e will be in one of several operating modes including Charging Discharging Idle Twi SBP 1100e User Manual light or Hibernation Accordingly the second line of the LCD will display Charging Dschging Idle or Twilight in response to pressing the SCROLL button at the appropriate step in the display cycle when the unit is not in hibernation When in hibernation mode the control panel is not active and there will be no response to button presses The SBP 1100e will come out of hibernation mode and the user interface will come back to life within three seconds after external power is applied or usually if RESET is pressed In the example below the unit is taking in power on the input connector and if it continues at this rate it will be fully charged in approximately 4 5 hours Charging 4 5HR In the example below the unit is discharging and if it continues at this rate it will be fully discharged in approximately 3 0 hours Dschging 3 0HR In the example below the unit is neither charging nor d
5. is fixed at the time of manufacture SBP 1100e Features e External dimensions approx 15 Lx 11 W x 6 5 H including receptacles with carrying handle folded e Fits within a space 16 Lx 12 Wx 7 H but 12 additional length should be allowed for cable bends e Integrated battery monitor panel reports condition and state of charge percentage e Can be recharged more than 400 times typically e Durable rugged water resistant and crush resistant case airtight with pressure relief valve e 100 depth of discharge allowed versus 30 to 60 for lead acid storage battery technologies e Light weight a third of the size and weight of comparable sealed lead acid packs with casing and venting e Deep discharge WITHOUT damage no urgency to re charge e Automatic shut down at full discharge with preceding user notifications e Rapid charging 10 hrs to full charge from empty using AC power adapter SBP AC ADAPTER 24V 130W e Integrated battery pack protection circuitry for safety e Partial charge discharge cycles OK no memory effects e Cells do not out gas environmentally benign compared to lead or nickel cadmium chemistries SBP 1100e Specifications x 13 8 volts DC 4 for nominal 12 volt applications 25 3 volts DC 4 for nominal 24 volt applications Standard Output Voltages factory set 4 pp 4 pp r A or volts 4 factory set Other Output Voltages examples 6 9 12 4 16
6. stops automatically when it reaches the highest state of charge possible There is no need to turn off or dis connect the charging power source when charging is complete or be concerned about over charging Battery Charging Using DC Power Sources Generally the SBP 1100e may be charged from filtered DC power sources ranging from 10 volts to 28 volts provided the source can supply 200 watts The power source need not be voltage regulated e g solar panels 12V 24V genera tors but the voltage must not exceed 28 volts However only charging sources supplied or approved by 1100 Energy should be used for charging the SBP 1100e Please contact 1100 Energy for details Unfiltered DC power sources such as automotive battery chargers should not be used for charging the SBP 1100e Automotive power by direct connec tion to the battery of a vehicle with the engine running may generally be used to charge the SBP 1100e At low voltages 10 12 volts the SBP 1100e may draw 20 amps while charging so avoid connecting the unit to an automotive DC power jack cigarette lighter jack if the jack is fused at less than 20 amps Battery Charging Using MF15 3600 Solar Panels If the SBP 1100e is to be charged from MF15 3600 Solar Panels connect a minimum of three solar panels using a compatible solar adapter cable see Accessories Depending on the average power requirements of the load and the amount of sunlight available up to eight solar panels may be n
7. SBP 1100e Smart Battery Power System User Manual Software version 4 1 2 NOOENERGY Warranty Statement All 1100 Energy products are warranted for 90 days from the date of purchase Any defects due to workmanship or materials will be repaired or replaced at 1100 Energy s discretion within the warranty period Normal Wear and Tear Periodic maintenance repair and replacement of parts due to normal wear and tear are excluded from coverage Abuse and Misuse Defects or damage that result from a Improper operation or storage misuse or abuse accident or neglect such as physical damage to the surface of the product resulting from misuse b Subjecting the product to abnormal usage or conditions c Other acts which are not the fault of 1100 Energy are excluded from coverage e Unauthorized Service or Modification Defects or damages resulting from service testing adjustment installation maintenance alteration or modification in any way by someone other than 1100 Energy or its authorized service centers are excluded from coverage UM SBP1100e1110R1 0 SBP 1100e User Manual IH Table of Contents General Description o IV SBP 1100e Features 1 SBP 1100e Specifications 1 Turn on Wake up from Hibernation 2 Control Panel Buttons and the LCD Disp
8. SCROLL once will turn it off and if the power output is off pressing SCROLL once will turn it on The change in output voltage and current resulting from turning the output on or off will not appear immediately on the LCD display because the display is a frozen snapshot of the state exist ing when the SCROLL button was pressed To see the new output voltage and current again press the SCROLL button repeatedly slowly until the new data is displayed Note that if there is no load connected to the SBP 1100e and the power output is turned off it may take 30 seconds or more for the indicated output voltage to fall below one volt due to stored charge in the output regulation circuit If a load is present the output voltage will instantly drop to zero when the output power is turned off The SBP 1100e has a very high power and energy density Mishandling may present a risk of fire or explosion Exer cise common sense precautions when handling transporting or testing DO NOT OPEN the battery pack case and replace individual cells or modules Usage should be carefully coordinated with 1100 Energy to ensure proper opera tion and safety SBP 1100e User Manual 5 Power Output Connection Specifications Output Mating Plug Model Ne SBP CON OUTPUT Output mating plug miniature cylindrical 5 pin male MIL C 26482 Series 1 shell size 14 plug 5 pin contacts 16 AWG MS3116F14 5P Cable 16 4 type SOOW 4 conductor 16 AWG cable
9. beled RESET and release The RESET dot is located just to the left of the SCROLL button on the LCD control panel on the top face hinged lid of the SBP 1100e Within 3 seconds the SBP 1100e will wake up and begin to initialize flashing mes sages on the LCD screen If needed connect power to wake up An SBP 1100e unit which holds a 50 charge when entering hibernation and which has remained in hibernation for a few weeks or less should be able to be awakened by pressing the RESET dot Should the unit become completely exhausted while in hibernation pressing the RESET dot will not awaken the unit In that case connect a charging power source such as the SBP AC Power Adapter item no SBP AC ADAPTER 24VDC 130W to the INPUT receptacle on the left side of the SBP 1100e Be sure the AC Adapter is plugged into a live AC out let and that the adapter power switch is on Within 3 seconds the unit should wake up and begin to initialize flashing messages on the LCD screen If not contact 1100 Energy for assistance Press SELECT to view product ID the initialization process takes one minute until the LCD display goes blank except for a row of grey raster rectangles which may appear dimly on the LCD screen After the display goes blank wait one more minute or less for initialization to complete then press the SELECT button to see the product identification and software version The software version should match the software version listed
10. charging power sources and to load equipment and data cables for control and monitoring purposes To see a list of accessories please visit our website at www 1100energy com or contact us Disposal At end of life please contact 1100 Energy for advice concerning disposal or recycling including options for returning the unit for refurbishing and renewal of the internal batteries Keep away from children Do not disassemble and do not dispose of in fire Contact information 1100 Energy Corporation 2145 Priest Bridge Drive Suite 7 Crofton Maryland 21114 Phone 410 721 9032 Email sales 1100energy com Web www 1100energy com 9 10 Eleven Hundred Energy Corporation 12 Eleven Hundred Energy Corporation 2010 1100 Energy Corportion 2145 Priest Bridge Drive Crofton MD 21114 410 721 9032 sales 1100energy com www 1100energy com
11. dation of the internal batteries reduces the energy storage capacity of the SBP 1100e below a level which is suitable for the application the SBP 1100e has reached the end of its service life In some cases an SBP 1100e unit may be returned to 1100 Energy reloaded with new lithium ion batteries and refurbished for continued use Contact 1100 Energy for details Cautions DO NOT open the battery pack case Doing so may risk personal injury DO NOT submerge battery pack in water DO NOT use battery pack cables not specified as compatible by 1100 Energy Charge the SBP 1100e at temperatures between 0 and 40 C The discharge and storage temperature ranges are 20 Cto 50 C and 20 C to 60 C respectively The SBP 1100e may present a risk of fire or chemical burn if mistreated DO NOT short circuit drop crush muti late nail penetrate reverse polarity disassemble or expose to temperatures above 100 C Lithium lon batteries are Class 9 hazardous materials subject to transportation restrictions including commercial air transportation Caution and planning should be exercised before transporting the SBP 1100e by common carrier ground transportation Standard Accessories SBP 1100e User Manual Standard accessories for use with the SBP 1100e include an AC Power Adapter for charging from utility power solar panels and solar panel adapter cables for solar charging and various power input and output cables for connection to
12. e equipment load and any additional input power which may be available is used to charge the internal batteries until the batteries are fully charged So long as some stored energy in the SBP 1100e is available to power the equipment load fluctuations in the input voltage and power will not affect the load equipment The SBP 1100e may be charged from any continuous filtered or low ripple DC power source of 10 volts to 28 volts capable of supplying 200 watts Acceptable power sources include vehicle 12 volt or 24 volt DC power systems AC powered DC power supplies and power adapters and solar panels which are intended for charging 12 volt lead acid batteries Specifically the SBP 1100e may be charged using portable solar panels manufactured by PowerFilm or by an AC power adapter both provided by 1100 Energy The AC adapter can be powered from any AC power source from 100 volts to 240 volts 50 or 60 Hz using a modular AC power cord A modular cord for U S 120 volt outlets is provided For use with other types of AC outlets the appropriate IEC modular power cord is required Consult 1100 Energy concerning other options for supplying charging and operating power to the SBP 1100e The SBP 1100e battery pack can be ordered with any fixed output voltage from 6 volts to 28 volts DC The standard out put voltages are 13 8 volts and 25 3 volts for use with equipment designed to run on vehicle power that ranges from 12 to 14 volts DC The output voltage
13. e without degradation to the battery s cycle life performance and without memory voltage depression problems The ideal usage pattern for lithium ion batteries is to be charged and discharged on a daily to weekly cycle as would be typical of a solar panel based application Prolonged storage at a high state of charge should be avoided as it degrades battery capacity but prolonged storage at a moderate or low state of charge 40 or less or in a fully discharged state is not harmful All batteries including lithium ion batteries will slowly self discharge while in storage After several months in storage lithium ion batteries may go dead but the batteries can be readily brought back to life by applying a suitable wake up charging regimen The SBP 1100e automatically applies the wake up charge regimen when appro priate and when charging power is made available The SBP 1100e should be ready for normal use after a couple of hours of wake up charging from a dead state although it will take longer than two hours to reach full charge Lithium ion batteries slowly degrade over time whether or not they are being used charged and discharged on a reg ular basis Provided the batteries have not been subject to prolonged storage at a high state of charge a typical useful service life might range from two to five years Typically the capacity rating will degrade by about 20 after about 300 charge discharge cycles When degra
14. econds after the last button press LCD panel indications The LCD panel on the top face of the SBP 1100e indicates the status of the unit in response to pressing the SCROLL button There is space for two lines of text or graphics on the display and when the SCROLL button is pressed the top line will display the present charge state in two formats the numerical percentage and a horizontal bar graph The per centage indicated is the relative state of charge between 0 fully discharged and 100 fully chargea The bar graph indication uses darkened blocks to represent full increments of 10 charge capacity In the example below the unit shows that it has 78 of full capacity left and the bar graph shows 7 blocks 78 EEHEEHE The second line of the LCD is used to display other operating parameters for the SBP 1100e including the status of charging or discharging output voltage and current and input voltage and current The charging or discharging status includes an estimate of the amount of time remaining for the unit to reach the end state of fully charged in the case of charging or discharged to the point of output cut off in the case of discharging assuming that charging or discharging continues at the present rate When the SCROLL button is pressed while the display is blank the backlight turns on and the state of charge appears on the top line of the display while the second line will show one of the following typical display
15. eeded The 2 pin connectors used to connect the solar panels to the cables should be tightly mated to keep out rain water and all the connectors should be kept out of rain puddles if possible Any unmated connectors should have the rubber safety caps which are tethered to them installed securely onto the connectors to protect from rain water Avoid using the connectors near hazardous voltages When the cable and panel connections have been made the charging status may be viewed on the status display on the SBP 1100e push the SCROLL button The SBP 1100e may be used to provide power to a load while the battery pack is being charged Charging stops automatically when the SBP 1100e reaches the highest state of charge possible There is no need to turn off or disconnect the charging power source when charging is complete and there is no need to be concerned about over charging Ideally the solar panels should be oriented so sunlight strikes them approximately perpendicular to the panel surface during the mid day hours when the sun is strongest For example in the Northern hemisphere at 40 degrees north latitude for best performance the panels should face south elevated about 40 degrees from the horizontal In a loca tion near the equator the panels should lie on a level surface The panels should not be in shadow during the mid day hours to the extent possible Power Input Connection Specifications Input Mating Plug Model Ne SBP CON INPUT I
16. eriods Store the SBP 1100e at 20 to 50 capacity and at low to moderate temperatures Prolonged storage at a high state of charge will degrade the storage capacity of lithium ion batteries Outdoor use The SBP 1100e is weather resistant and ruggedly packaged but when used outdoors it should not be left fully exposed to the weather if it can be avoided Direct sun can cause overheating and prolonged exposure to sun rain Snow Salt spray dust and wind blown debris may accelerate deterioration of the case and control panel Some covering Such as a rain shedding sun blocking tarp or lean to should be provided and the covering should allow for some natural circula tion of air around the SBP 1100e case during hot weather If the SBP 1100e is to be used in extremely hot or extremely cold outdoor environments shallow burial of the unit in the earth will moderate the temperature extremes Shallow burial might also be used as a means of hiding the SBP 1100e Since the earth may tend to become saturated with water from time to time due to rain some waterproof protective wrapping or bagging and or provision for drainage may be desirable Lithium lon Lithium lon packs unlike Lead Acid batteries do not have to be fully charged before use If charging is stopped prior to full charge the SBP 1100e can be discharged without diminishing cycle life In addition unlike NiCd and NiMH batter ies Li lon batteries can be recharged at any state of charg
17. he battery pack is being charged If the SBP 1100e becomes fully discharged and the output cuts off a small amount of residual stored energy will maintain functionality of the user interface for one hour or more This feature is partly for user convenience during at tended operation and testing and it also keeps the serial control and monitor interface functioning If no new charge is added after the output cuts off the user interface will cut off as well after 30 minutes and the unit will then appear to be totally dead with no power output no display and no response to button pressing The SBP 1100e is in hibernation However the user interface will come back to life within 3 seconds after external power is applied and after a suitable period of charging the SBP 1100e battery pack may again be used normally In the event that charging power is applied after the output has been cut off the state of charge must rise to about 15 before the output will be turned on again Power Output On and Off Control To check the output voltage and current press the SCROLL button on the Control Panel repeatedly slowly until the second line of text of the LCD display shows the output voltage and current for example Out 13 8V 00 0A This display will persist for eight seconds during which time the SELECT button may be pressed to toggle the power output on and off That is if the power output is on pressing
18. ht up and show data for 8 seconds then blink off During the 8 seconds display time the data is not updated in real time so if at any time up to date data is needed press the SCROLL button until the desired data set is displayed At any time status messages may appear which will over ride the data which would otherwise appear in response to button presses Sometimes a long series of such status messages may appear which may interfere with using button presses to obtain data In that case wait until the status messages have stopped before again pressing buttons Master Reset The master RESET button is located about inch to the left of the domed SCROLL button The RESET button is not domed to prevent it from being activated by accident The SBP 1100e may be reset at any time by pressing the button The process takes about two minutes and the output power will turn off during the reset then automatically turn on when the process is complete Battery Charging Using the AC Adapter If the SBP 1100e Smart Battery Power System is to be charged from an AC power source connect the AC power adapter SBP AC ADAPTER 24V 130W to an AC power source of 100 volts to 240 volts 50 or 60 Hz When the connection is made the charging status may be viewed on the control panel display on the SBP 1100e push SBP 1100e User Manual the SCROLL button The SBP 1100e may be used to provide power to a load while the battery pack is being charged Charging
19. ischarging and is not powering a load and thus is said to be idle Idle In the example below the unit is both charging or discharging that is some internal batteries are being charged while others are being discharged Dschrge amp Charge In the example below the input voltage and input current are displayed In 23 5V 3 2A In the example below the output voltage and output current are displayed Out 13 8V 4 3A In the examples below the input power converter operating temperature and the output power converter operating temperature respectively in degrees Celsius are displayed In Temptr 27C Out Temptr 43C In the event that the operating temperature of the input power converter reaches 95 C charging will be automatically cut off until the temperature falls below 90 C Likewise if the operating temperature of the output power converter reaches 95 C the power output will be automatically cut off until the temperature falls below 90 C In addition to the informational responses which appear on the LCD in response to pressing the SCROLL button spon taneous informational messages or warnings may appear on the LCD Storage 7 8 Eleven Hundred Energy Corporation e Recommended temperature range for storage 20 C 4 F and 60 C 140 F store at low to moderate tempera tures to maximize battery life Storage at temperatures above 45 C 113 F reduces battery life e Prolonged storage p
20. lay 2 M ster Reset is His tee e ae D Pres 2 Battery Charging Using the AC Adapter 2 Battery Charging Using DC power sources eae 3 Battery Charging Using MF15 3600 Solar Panels 3 Power Input Connection Specifications 3 Supplying Powerto a Load 4 Power Output On and Off Control 4 Power Output Connection Specifications 5 Serial Data Port s cier Bee Re Se tee we we 5 Serial Data Port Connection Specifications 5 Control Panel BURONS 24123 amp sg see age ne das 6 LCD Backlighting ca due dE due ec die dan we deco de 6 LCD Panelindications 24 masses PR Etre 6 SIDA D is se te Dames Dai ee 8 OudOOnUSe es sr da a an ose Diam S 8 Lithiumslons 4 eh sue a RO Re R Re Da dot 8 CAUSA ae eee Se ee ne 8 Standard Accessories 9 Disposal 4 oreg se ss ra ta s sis a RR dus s 0e 9 Contact Information 9 IV Eleven Hundred Energy Corporation General Description The SBP 1100e Smart Battery Power System is a rugged state of the art lightweight high energy density rechargeable portable power system that is an ideal solution for even the mos
21. nput mating plug miniature cylindrical 5 pin female MIL C 26482 Series 1 shell size 14 plug 5 socket contacts 16 AWG MS3116F14 5S Cable 16 4 type SOOW 4 conductor 16 AWG cable Water and oil resistant rubber jacketed cable Connection Wiring Diagram Pin Description Wire Color DC Input Return D__ DC Input Return E No Connection No Connection 5 Pin Female Input Mating Plug mating face view 3 4 Eleven Hundred Energy Corporation Supplying Power to a Load To use the SBP 1100e to power a DC load first determine whether the fixed voltage provided by the SBP 1100e e g 13 8 VDC or 25 3 VDC etc is appropriate for the load and that the power demanded by the load will not exceed 300 watts on a continuous basis If continuous power in excess of 300 watts is required consult 1100 Energy Connect the SBP 1100e power output jack on the right side of the unit to the load using the provided cable or other approved cable A short output cable terminated with ring terminals provided by 1100 Energy may be used to con nect with another longer user provided cable if appropriate User specified extension cables should be of a wire gauge adequate to avoid an excessive voltage drop in the extension cable The panel display may be controlled to show the voltage current and an estimate of the remaining battery pack charge as a percentage of the charge capacity The SBP 1100e may be used to provide power to a load while t
22. on the cover of this User Manual Press SCROLL to view mode and charge state Press the SCROLL button to view the state of charge and the operational mode The state of charge will appear as text on the top line of the LCD display e g 43 and in a graphical represen tation e g four black blocks for a state of charge from 40 to 49 The operational mode will appear on the bottom line of the LCD display unless the unit is charging in which case Charging will appear If the mode is Idle the unit is ready for use If the mode is Twilight connect a charging power source as described above and allow the unit to charge at least until the state of charge reaches about 15 To check whether the unit is ready for use disconnect or turn off the charging power and press SCROLL to check the mode if the mode is Idle the unit is ready for use If de sired re connect or turn on the charging power to continue charging The SBP 1100e does not have to be fully charged before being put to use powering a load and the unit may deliver power to the load while continuing charging Control Panel Buttons and the LCD Display If the LCD display does not respond to pressing the SCROLL and SELECT buttons wait one minute for the condition to correct itself and try again If the display still does not respond press the RESET dot then wait two minutes and try again After pressing the SCROLL or SELECT button the LCD display will lig
23. onsult 1100 Energy for other charging options Output Noise and Ripple 100 mV peak to peak at maximum load for 25 3 volts DC output Noise and ripple are proportionate to loading Power Input Receptacle MS3112E14 5P 5 pin contact male MIL receptacle box mount Power Input M MS3116F14 5S 5 socket contact female MIL plug cable mount with strain relief clamp Plug is available from 1100 Energy as item no SBP CON INPUT Power Output Receptacle MS3112E14 5S 5 socket contact female MIL receptacle box mount Power Output Mating Plug MS3116F14 5P 5 pin contact male MIL plug cable mount with strain relief clamp Plug is available from 1100 Energy as item no SBP CON OUTPUT Serial Data Receptacle MS3112E10 6P 6 pin contact male MIL receptacle box mount Serial Data Mating Plug MS3116F10 6S 6 socket contact female MIL plug cable mount with strain relief clamp Plug is available from 1100 Energy as item no SBP CON DATA ting PI 2 Eleven Hundred Energy Corporation Turn on Wake up from Hibernation Hibernation The SBP 1100e will automatically enter a hibernation state after 30 minutes of non use and provided that no live charging power source is connected This is done to conserve the stored energy which powers the unit and thereby extend the energy retention shelf life of the unit Press RESET to wake up To turn on or wake up the unit press firmly with a fingertip on the small silver dot la
24. t demanding of applications The SBP 1100e can be used as a source of power for applications such as communications equipment as well as 1100 Energy s infrared sig naling and marking products Based upon Lithium lon battery cell chemistry the SBP 1100e delivers power with much less weight and bulk than traditional battery systems The SBP 1100e power output provides a regulated DC voltage for running various types of equipment for diverse appli cations Capable of providing up to about 300 watts of power the SBP 1100e can store up to 1100 watt hours of energy internally of which up to about 1000 watt hours can be delivered to an external load before a recharge is needed The system can power for example a 100 watt load for about ten hours or lesser loads for proportionately longer periods of time using its stored energy The SBP 1100e provides graceful degradation of performance in the event that one or more Lithium lon battery units within the system should fail the energy storage capacity will decrease proportionately instead of resulting in system failure The SBP 1100e power input is configured for direct charging by solar panels designed for charging 12 volt lead acid battery systems The high efficiency charging circuit is built in The SBP continues to power the application equipment during solar charging and afterwards using the stored energy In using input power available to the SBP 1100e priority is given to Supplying power to th

Download Pdf Manuals

image

Related Search

Related Contents

SmartGate UMTS User guide  Engine Controller - Martin Diesel Inc  Bahreïn  Développer vos compétences pour grandir ensemble  User manual EN  Husqvarna 265 ACX Lawn Mower User Manual  Installation Manual NAVIGATIONAL ECHO SOUNDER FE-700  Das HTC EVO 3D - Handy Deutschland  LADER ANLOG  halsey taylor owners manual manual del propietario halsey taylor  

Copyright © All rights reserved.