SolarPower Manual (10kw)
Contents
1. I Allow to feed in to the Grid Load supply source PV is unavailable Grid Battery Load supply source PV is available P Grid Battery Priority 1st PY gt 2nd Grid gt 3rd Battery eee ea PM Allow battery to feed in to the Grid when PV is unavailable PM When battery voltage lt o aH Y the AC starts charging s R Allow AC charging duration 00 00 04 00 00 00 00 00 Means AC charger operates all time AC Output ON Off Timer 00 00 fee i 00 00 pee 00 00 00 00 means AC Output timer function disable Apply Close PV energy supply priority setting 1 Battery 2 Load and 3 Grid PV power will charge battery first then provide power to the load If there is any remaining power left it will feed in to the grid Battery charging source 1 PV and Grid It s allowed to charge battery from PV power first If it s not sufficient grid will charge battery 2 PV only It is only allow PV power to charge battery 3 None It is not allowed to charge battery no matter it s from PV power or grid Load supply source When PV power is available 1 PV 27 Grid 3 Battery If battery is not fully charged PV power will charge battery first And remaining PV power will provide power to the load If it s not sufficient grid will provide power to the load If grid is not available at the same time battery power will back up 23 When PV power is not available 1 1 Grid 2 Batte
2. Allow battery to feed in to the Grid when PV is available This option is only valid in Grid tie with backup II or Grid tie with backup III modes Allow battery to feed in to the Grid when PV is unavailable This option is only valid in all options of Grid tie with backup mode 4 2 2 Parameter Setting Select Device Control gt gt Parameter Setting or select shortcut icon It will display available parameter settings when setting operation mode NOTE This screen may be different for different mode settings of solar inverters When setting in Grid tie with backup mode or Grid tie mode some parameters are related to local grid standard and can t be modified without factory password Please refer to red squares in Diagrams 4 11A and 4 11B Any mis setting could cause inverter damage or not working Please check local dealers for the details Refer to Diagram 4 12C for off grid setting mode Step 1 Select the functions by clicking Enable or Disable button Or change the numbers by clicking up down arrows or modify the numbers directly in the number column Step 2 Click Apply button to save the settings Each function setting is saved by clicking each Apply button 33 Min grid connected voltage 184 Apply The waiting time before grid connection Max grid connected voltage 264 5 Apply Max grid connected average voltage Min grid connected frequency 47 48 ma App ly Max feed in grid power
3. If PV power and battery energy are not available utility will provide power to loads directly There will be power flow animation from solar module icon to the load icon If only utility power exists it will charge battery and provide power to the load There will be power flow animation from utility icon to battery and load icons If only PV power exists without battery connected it will provide power the load If there is remaining power it will feed in to the grid There will be power flow animation from PV module icon to load icon and to the utility icon If PV power is sufficient but battery power is insufficient PV power will charge the battery provide power to the load and feed in to the grid There will be power flow animation from PV module icon to battery to load icon and to utility icon If PV power is weak utility exists and battery power is insufficient PV power and utility power will charge battery at the same time Besides utility power will provide power to the load There will be power flow animation from PV module and utility icons to battery icon and another power flow from utility icon to load icon Inverter mode Utility power is not available or not connected during this mode All possible power flows are described as below il If PV power is not available battery power will provide power to the load There will be power flow animation from battery icon to load icon If PV power is available and suffic
4. PDF file Delete Select specific data and click Delete button to delete the record Delete all Click Delete All button to delete all records on the listed table Device dO000000000000 Display item Ej Device mode Time period 2014 10 24 2014 10 24 Export excel P 1 input p jP 2 input p J Grid voltag Grid voltag Grid voltag Grid freque Load level Battery volt Battery cap Charging t Temperature 4797 3982 230 3 49 97 0 55 9 98 28 0 58 0 Time 2014 10 2 2014 10 2 Jevice mode Grid tie wit P 1 input 488 3 P 2 in inp ut 237 1 E Grid tie wit Grid tie wit 201 4 10 2 Grid tie wit 2 Grid tie wit 2 2 483 9 Grid tie wit 2 Grid tie wit 2 Grid tie wit 20 230 Grid tie wit 2 9 98 oe 3 Grid tie wit 2 Grid tie wit 2 Grid tie wit 2 Grid tie wit Grid tie wit 2 a m he TI oe 50 0 ETT E TE 27 Ff AD Grid tie wit 2 Grid tie wit 2 Grid tie wit 2014 10 Grid tie wit 2 10 2 2014 10 2 2m14 1nN 9 Grid tie wit 1020 ATOA AQTA INIBA INIA anni SAN 2n 1 ann Export Delete Delete all Close Grid tia swit Total 50 rows Diagram 4 17 e Charts Select View gt gt Data gt gt Charts Refer to Diagram 4 18 Select browsed device and period and then click Browse to get the result 42 Datasheets 1388 00000000000000 v Period NO Y
5. PS to enter event log Select View gt gt Event log or click shortcut icon gt Export excel When selected and click Export it will save listed table to local PC in xls file gt Export Click Export button to save listed table to local PC in PDF file gt Delete Select specific data and click Delete button to delete the record gt Delete all Click Delete All button to delete all records on the listed table Device OO0000000000000 wv Time period 2014 10 24 2014 10 24 Browse ID Time Event 2022 2014 10 24 18 03 42 AC input waveform abnormal 2 Warning Solarinput1 loss 2018 tarni 201 4 10 24 18 03 42 AC input phase sequence error 2 2015 2014 10 24 18 03 42 2013 Waming Netzfrequenz geringer Verlust 2002 arni 2 Warning AC input phase sequence error 2001 2014 10 24 18 03 42 2022 Warning AC input waveform abnormal 3001 Wlessa Messa Communication restore hm o Ja hm E po co o i Fa ho O o 3 m 2 oO om i l om 5 7 f 1 1 1 1 a D 0 2001 2002 2011 2013 2015 2016 2018 2022 3001 Export Delete Delete all ID Warning as A A e O as as ESS a Close l Diagram 4 20 4 3 5 Monitored Device Information This screen will display basic information of monitored device including Product information Rated information and Purchasing information Select View gt gt Monitored Device Inform
6. 1 to 60 minutes The default setting is 5 minutes 6 Auto time calibration If selected it will automatically calibrate the system time 7 Date format This system supports 4 different formats YYYY MM DD 14 YYYY MM DD MM DD YYYY and MM DD YYYY The default setting is YYYY MM DD 8 Temperature format This system supports Centigrade C and Fahrenheit F The default setting is Centigrade C If any change is made simply click Apply button in the end of each item Then the setting will be saved 4 1 2 Password It s password setting for administrator only Before operating and configuring the software please login first and modify the password The default password is administrator at first log in As a guest status user only can browse solar inverter status and information without controlling or modifying any settings Step 1 Select SolarPower Configuration gt gt Password Refer to Diagram 4 4 Password Old password e a Mew password 00000 Confirm bas swore i AL Diagram 4 4 Step 2 Enter old password new password and re type new password to modify password for administrator The password should be at least 6 digits Then click Apply button to successfully modify password for administrator NOTE1 Simply click Login button on the top right corner to log in the software NOTE2 If password is forgotten it s necessary to re i
7. 2535 i Min grid connected frequency 47 48 my Max feed in grid power 10 000 pa Max grid connected frequency 51 5 Hz Appl Feed in power factor lo Min PV input voltage App y Min MPP voltage 3505 Max PV input voltage App y Max MPP voltage 850 Start LCD screen saver after None Mute Buzzer alarm Enable _ Disable Wide AC input range D Enable Disable Apply Mute the buzzer in the Standby mode Enable Disable Apply When float charging current is less than X A and x om A T 60 Min C Any schedule change will affect the power generated and shall be conservatively made System time 2015 01 19 B 15 44 31 Apply Diagram 4 11B Grid Tie mode ch to Min PY input voltage 300 y Floating charging voltage Maz PY input voltage 900 Y Battery cut off discharging voltage when Grid is available ga da aa da da di Min MPP voltage 350 y Battery re discharging voltage when Grid is available En EE Maz MPP voltage 850 VW Apply Battery cutoff discharging voltage when Grid is Unavailable Max charging current 60 A Apply Battery re discharding voltage when Grid is unavailable Max AC charging current 60 A Apply Battery temperature compensation Bulk charging valtageit w voltage Shwe Y Feeding grid power calibration Start LCD screen saver after 60 Sec Max battery discharge currentin hybrid mode Mute
8. Device P N Apply Diagram 4 21 NOTE This screen may be different for different settings of solar inverters 4 4 Login and Logout e Icon to display users don t log in SolarPower a Icon to display users has logged in SolarPower gt Click icon and enter password to log in the software The default password is 45 administrator Refer to Diagram 4 22 SolarPower SolarPower configuration Device control View Language Help 7 e gt E Calla ia pe i pr Guest Monitored device USB14200000_00000000000000 System time 2015 01 19 16 33 20 Temperature 37 0 C 2 pan cun bin nb vcn vol corp Basic information USB14200000_0000000000000 Sau PV1 input voltage AC output active power R Grid tie with backup wie PV2 input voltage j AC output active power S Grid voltage R AC output active power T Grid voltage S Total AC output active power Grid voltage T AC output apparent power R Grid frequency AC output apparent power S Load level AC output apparent power T Charging current j Total AC output apparent power Please login first Battery voltage i inner temperature Password seeceeeeeeeees Login Gear Battery capacity Max component temperature Power information PV1 input power PV2 input power Today This month This year 0 0 0 0 0 0 10 11 R B IKI 15 2015 01 19 Diagram 4 22 Click iconliaa to log out Refer to Diagram 4 23 SolarPower SolarPower configuration D
9. PY and Grid Please enter factory password PY charging first If P Password Login Clear P V Grid Battery Priority 1st PY 2n Grid Battery Priority 1st Grid gt 2nd Battery 00 00me Y the AC starts charging 04 00 0 00 00 00 00 Means AC charger operates all time 00 00 i 00 00 00 00 00 00 means AC Output timer function disable Nominal output frequency 50 F Allow to feed in to the Grid baal m M Allow batte ry to feed in to the Grid when P is unavailable Apply Close Standard It will list local grid standard It s requested to have factory password to make any modifications Please check local dealer only when this standard change is requested CAUTION Wrong setting could cause the unit damage or not working Nominal Output Voltage There are 5 options for high voltage system to select 240V 230V 220V 208V and 202V Nominal Output Frequency There are 2 options to select 50HZ or 60HZ 22 4 2 1 2 Setting Grid tie with backup e Grid tie with backup I Mode Grid tie with backup Crete Oren SEE DEDI 26 yy Nominal output voltage 230 v Nominal output frequency 50 n Setting PY energy supply priority setting Grid Tie with Backup 1 Priority 1st Battery gt 2nd Load gt 3rd Grid Configuration details Charging source PY and Grid v P charging first If PY power is not sufficient PY and grid will charge battery together
10. e Nominal output frequency 50 e setting PY energy supply priority setting Off Grid Il y Priority 1st Load gt 2nd Battery Grid relay is disconnected in inverter mode Configuration details Charging source PWY or Grid pa PY will charge battery first If PY power is loss grid will charge battery ei i a Load supply source P is available PY Battery Grid Priority 1st PY gt 2nd Battery gt 3rd Grid Load supply source PY is unavailable Grid Battery Priority 1 st Grid gt 2nd Battery ee lt a Be MM When battery voltage lt 48H Y the AC starts charging Allow AC charging duration DO0 00 ma 04 00 00 00 00 00 Means AC charger operates all time AC Output ON Off Timer 00 00 fee i 00 00 00 00 00 00 means AC Output timer function disable Apply Close 31 PV energy supply priority setting 1 Load 2 Battery PV power will provide power to load first and then charge battery Feed in to the grid is not allowed under this mode The grid relay is NOT connected in Inverter mode That means the transfer time from inverter mode to battery mode will be about 15ms If connected load is over 10KW and grid is available this inverter will allow grid to provide power to the loads and PV power to charge battery Otherwise this inverter will activate fault protection Battery charging source 1 PV or Grid If there is remaining PV power after supporting the loads it will
11. installer Cancel Diagram 2 8 Note Please uninstall the previous version before install the new version software 5 2 3 Software Uninstall Please choose Start gt gt All Programs gt gt SolarPower gt gt Uninstall Then follow the on screen instruction to uninstall the software Note Before uninstall software you must stop all software programs first and then log in as Administrator Otherwise it can t be uninstalled completely 3 Tray Application 3 1 Startup The Installer will leave a shortcut icon called SolarPower on your desktop Refer to Diagram 3 1 Simply double click the shortcut Then it will start the software and display a service icon located in tray It will pop up function menu by clicking right button of the mouse Refer to below diagram 3 2 Diagram 3 1 Configuration software Upgrade F Open Monitor Exit Diagram 3 2 3 2 Configuration 3 2 1 Configuration Refer to Diagram 3 3 for the detailed configuration for online upgrade e Specify the URL to update files This is the directory to online update software Please do not change it unless it s instructed by software vendor o Save files to The directory to save files e Online auto update If selected it will automatically check if there is any new version launched online every 1 hour If applying online upgrade please follow below steps for configuration 1 Select Apply the proxy configuration
12. of solar inverters 4 1 SolarPower Configuration 4 1 1 Basic This page is to set basic display parameters Select SolarPower Configuration gt gt Basic Refer to Diagram 4 3 Page refresh interval Output information Update interval Device scan interval Smee SEC Record interval SEC Max allowable time difference 3 hin PJ automatic calibrate the s yStem time Date format YYrr Mmbo Temperature format Centigrade Apply Close Diagram 4 3 1 Page refresh interval This interval time will determine how long the web page is refreshed Setting range is from 5 to 600 seconds The default setting is 5 seconds 2 Output information update interval This interval time will determine how long the power generation data is updated Setting range is from 10 to 600 seconds The default setting is 20 seconds 3 Devices scan interval This interval time will determine how long device scanning action will be executed The setting range is from 5 to 600 seconds The default setting is 5 seconds 4 Record interval This interval time will determine how long the monitoring data of solar inverters will be recorded into database The setting range is from 30 to 600 seconds The difference between each option is 30 seconds The default setting is 60 seconds 5 Max allowable time difference It will send alarm message when the time difference between device and computer is longer than setting time The setting range is from
13. the grid Feed in to the grid is default disabled Battery charging source PV only Only after PV power fully supports the load the remaining PV power is allowed to charge battery during peak time Load supply source 1 PV 274 Battery 3 Grid PV power will provide power to the load first If PV power is not sufficient battery power will back up the load If battery power is not available grid will provide the load When PV power is not available battery power will supply the load first If battery power is running out grid will back up the load Working logic under off peak time PV energy supply priority 1 Battery 2 Y Load and 3 Grid PV power will charge battery first If PV power is sufficient it will provide power to the loads The remaining PV power will feed to the grid NOTE The max feed in grid power setting is available in parameter setting Please refer to section 4 2 2 27 Battery charging source PV and grid charge battery PV power will charge battery first during off peak time If it s not sufficient grid will charge battery Load supply source 1 PV 2 Grid 3 Battery When battery is fully charged remaining PV power will provide power to the load first If PV power is not sufficient grid will back up the load If grid power is not available battery power will provide power to the load Grid Tie Under this operation mode PV power only feeds in to the grid No priority setting is av
14. time and the priority will automatically become 1 Grid and 2 Battery order Otherwise it will cause battery damage e Grid tie with backup III Mode Grid tie with backup Standard YDE0126 Setting PY energy supply priority setting Grid Tie with Backup di Priority 1st Load gt 2nd Grid gt 3rd Battery Configuration details Charging source PY and Grid Nominal outputvoltage 230 e PY charging first If PY power is not sufficient PY and grid will charge battery together Load supply source PY is available P Battery Grid Priority 1st PY gt 2nd Battery gt 3rd Grid Load supply source PY is unavailable Battery Grid Priority 1st Battery gt 2nd Grid This option is ineffective during of AC charging MM When battery voltage lt Allow AC charging duration 00 00 e 04 00 ma AC Output ON Of Timer MN 00 00 e DEES vv the ac starts charging 00 00 00 00 Means AC charger operates all time 00 00 00 00 means AC Output timer function disable Nominal output frequency 50 PI Allow to feed in to the Grid PM Allow battery to feed in to the Grid when PY is available PA Allow battery to feed in to the Grid when PY is unavailable Apply Close PV energy supply priority setting 1 Load 2 Grid and 3 Battery PV power will provide power to the load first If there is more PV power available it will feed in to the grid If feed in power reaches max feed in power setti
15. 00 00 Means AC charger operates all time AC Output ON Off Timer 00 00 mes l 00 00 pes 00 00 00 00 means AC Output timer function disable Apply Close 4 2 1 1 Mode There are three operation modes Grid tie with backup Grid Tie and Off Grid e Grid tie with backup PV power can feed in back to grid provide power to the load and charge battery There are four options available to select in this mode Grid tie with backup I II III IV In this mode users can configure PV power supply priority charging source priority and load supply source priority However when Grid tie with backup IV option is selected in PV energy supply priority the inverter is only operated between two working logics based on defined peak time and off peak time of electricity Only peak time and off peak time of electricity are able to set up for optimized electricity usage e Grid Tie PV power only can feed in back to grid e Off Grid PV power only provides power to the load and charge battery 2 MyPower Management Mode Grid tie with backup Setting PY energy supply priority setting Grid Tie with Backup l Standard VDE0O126 e Nominal output voltage 230 e Priority 1st Battery gt 2nd Load gt 3rd Grid Configuration details Charging source Load supply source PY is available Load supply source PY is unavailable MM hen batte ry voltage Allow AC charging duration AC Output ON Off Timer
16. 2bit amp 64bit Linux SUSE 10 32bit amp 64bit Linux Cent OS 5 4 32bit amp 64bit Ubuntu 8 x 9 x 10 x 32bit amp 64bit Linux Fedora 5 Vv Vv VW Y Y VW VY VY WV Linux OpenSUSE 11 2 32bit amp 64bit l Linux Debian 5 x 6 x 32bit 8 64bit Mac OS 10 6 x64bit Mac OS 10 7 x64bit Mac OS 10 8 x64bit Mac OS 10 9 x64bit Vv Vv VW VY VY WV Mac OS 10 10 x64bit 2 2 Software Install Step 1 After clicking install it will display the installation in process Refer to the diagram 2 1 InstallAnywhere tm Installnywhere 1s preparing to install Cancel C 1997 2008 Acresso Sofware Inc andor Installshield Co Inc Diagram 2 1 Step 2 Choose wanted language and click OK as diagram 2 2 Diagram 2 2 Step 3 Click Next to proceed to the next screen as Diagram 2 3 lnstallAnvwhere will guide you through the installation of SolarPower A A tis strongly recommended that you quit all programs before house S ortcut r oldar continuing with this installation Pre rrsteilletiory Sres Click the Mest button to proceed to the next screen Ifyou want to change something on a previous screen click the Previous button risstellirig Install Correlate You may cancel this installation at anytime by clicking the Cancel button Previous Diagram 2 3 Step 4 Click Choose button to change the default folder After choosing the installed folder cl
17. 6 2 Enter IP address and port of server 3 If ID identification is requested click Enable authentication and enter User Name and Password e Connection test Click this button to test if all configurations are set up well Specify the URL for update files examples SolarPowerl SlupdatesolarPower zip save fillesto CiProgram FilesioolarPowerl 00 lpgradeFiles Browse Online auto update Apply the prow configuration E Por E erable aumnenticaion User nare EA Connection test Apply Cancel Diagram 3 3 3 2 2 Configuration Saved Click Apply button to save all changes in Configuration page Click Cancel to stop the change 3 3 Software Upgrade Software upgrade includes online upgrade and manually upgrade e Online Upgrade Click Online Upgrade to search the latest software version If there is new version it will automatically download and upgrade Refer to Diagram 3 4 Configuration Online Upgrade sofware Upgrade P Manually Upgrade Si Open Monitor Exit Diagram 3 4 e Manually Upgrade Users can manually upgrade the software Follow below steps 1 Click Manually Upgrade from function menu Refer to Diagram 3 5 Configuration Online Upgrade Software Upgrade Manually Upgrade ae ce E Open Monitor Exit Diagram 3 5 2 Click Browse to choose file directory Then click Upgrade to upgrade software Refer to Diagram 3 6 ia
18. AE 40 A O O OO NT 40 4 3 1 Power generation log data 40 A IDA a EA A E E A 42 Ador Faut data lOQ secano 43 Arcas AE VEIA A A O 44 Ar Monitored Device Information ainia ia ia toed tind eeu AA LO IN and LOG OUT nido aaa AS RO AO MAD 1 SolarPower Overview 1 1 Introduction SolarPower is a smart solar inverter monitoring software to monitor multiple devices via USB and Serial port at the same time The major functions of SolarPower monitoring software include data log for devices power generation statistics alarm messages fault messages and parameter settings for devices 1 2 Features e Automatic and real time data acquisition of devices and secured data log saving Graphic display of device data for quick and easy reading Warning notifications or fault alarms via mobile messenger tray message and e mail Easy diagnosis from event statistics and amount calculation for energy saving Supports online upgrade and manually upgrade 2 SolarPower Install and Uninstall 2 1 System Requirement 512 MB physical memory at least 1 GB is recommended 2GB hard disk space at least Administrator authority is required More than 32 bit colors and 1280 x 800 or above resolution display is recommended An available communication port is needed Platforms supported by software are listed below Windows 2003 XP Vista 2008 32bit amp x64bit Windows 7 8 32bit amp x64bit RedHat Linux 8 9 Linux RedHat Enterprise AS3 AS5 AS6 3
19. Buzzer alarm CJ Enable CJ Disable Ei ly Generator as AC source Enable C Disable Apply hute the buzzer in the Standby mode Enable CJ Disable 20 nly Activate Li Fe battery while commissioning CJ Yes No Apply Mute alarm in battery mode Enable Disable Egan Wide AC inputrange Enable Disable Apply When float char gin gq curre ntis less than X A and continued T Min then cha rer off when batte ry voltage is less than Y fy the ncha rger o a gain ee T eog Min T Apply O Any schedule change will affect the power generated and shall be conservatively made System time 2014 10 27 i Apply Diagram 4 11C Off Grid mode e Min grid connected voltage The acceptable low voltage point for solar inverter with grid connected e Max grid connected voltage The acceptable high voltage point for solar inverter with grid connected e Min grid connected frequency The acceptable low frequency point for solar inverter with grid connected e Max grid connected frequency The acceptable high frequency point for solar inverter with grid connected e The waiting time before grid connection e Max grid connected average voltage When the average voltage is higher than this setting it will be identified as the utility is abnormal e Max feed in grid power Maximum power to feed in to the grid e Min PV input voltage The acceptable low voltage point for PV terminals when grid connection i
20. Max grid connected frequency 51 5 HE ADD ly Feed in power factor 15 Min PV input voltage 300 Apply Floating charging voltage 54 Max PV input voltage 900 p ply Battery cut off discharging voltage when Grid is available 48m Min MPP voltage 350m Apply Battery re discharging voltage when Grid is available 54 Max MPP voltage 850 Apply Battery cut off discharging voltage when Grid is unavailable 42 Max charging current 60 Apply Battery re discharging voltage when Grid is unavailable 48m Max AC charging current 60 Apply Battery temperature compensation a Bulk charging voltage C V voltage s6 Apply Feeding grid power calibration 1 Start LCD screen saver after None Max battery discharge current in hybrid mode 3005 Mute Buzzer alarm Enable itm Apply Generator as AC source _ Enable Disable Mute the buzzer in the Standby mode lt Enable _ Disable iter Activate Li Fe battery while commissioning lt Yes 2 No Mute alarm in battery mode _ Enable _ Disable Miter Wide AC input range lt Enable _ Disable oD aA 60 Min Any schedule change will affect the power generated and shall be conservatively made System time 2015 01 19 15 42 42 Apply Diagram 4 11A Grid Tie with Backup mode Min grid connected voltage 1845 App y The waiting time before grid connection 60 Max grid connected voltage 264 5 Apply Max grid connected average voltage
21. SolarPower User Manual Suitable Products e Three phase grid tie inverter with energy storage e Three phase off Grid inverter Management Software for Solar Inverter Table of Contents 1 SOlarPOWEE OVer VIO W izan Ra REA RARE 1 als PI EEOEU CON aca 1 A A A A OR A 1 2 SolarPower Install and Uninstall ooooocccncccccncccccnnncncnnnnnnnnnnnnn ns 1 230 System RequiFe ment A 1 22 aOMWare Stalin a A E A E A T A AA AE E 2 23 Somtware UMASA artun A a 6 3 tray ADDIICACION ciinii enin NaRa ARERR 6 e tU te ala a ao 6 3 2 COMIgura cOn a eae eee a ee aaa 6 TZ CONIL Sate ni ala tau Es 6 Sil CONMGUALION SAVE i ccccie ce nesveras ore car noneces iia 7 Bo SOWIE Upa ra de ici 7 3 4 AcOM and SOMWale Stata 8 Bao Open Moni o e A 9 20 Blast iras adios 9 4 SolarPower GUI TOtertace sra 10 AL SOlarPOWer COnMGUrAtION sii AAA AA ANA AAA 14 Aal A OO O OO a 14 Az PASS WO FO ii A iaa 15 Aake ar SN S SetU NG deat ea timedaatmeet ee a a cent cae ana ceeacat en neem n et ceeccents 15 AA OV else ce is 18 ole EVENE CUO MM a teeth cet a a Wtadau ol malate E tte E A dau waded 19 4 1 6 Com port Plug And Play Setting sisi A 20 4 2 Device CONTEO A OS 21 4 2 1 MyPower Management ssiccexcs lt ieceectaweceamietecstoosveeexeestecsnaiavedeteboladstateeedetacaieos 21 4 2 2 Parameter Setecientos A Aa 33 Aza Restore to the defaults seirinin a a cet Go a a 38 A24 QUEPUt Sync FONIZa tion datan aa 39 Alia Realtime CONTO Eiana a A AE EA N
22. Timer 00 00 pee l 00 00 00 00 00 00 means AC Output timer function disable PV energy supply priority setting 1 Load 2 Battery and 3 Grid PV power will provide power to the load first Then it will charge battery If there is any remaining power left it will feed in to the grid Battery charging source 1 PV and Grid It s allowed to charge battery from PV power first If it s not sufficient grid will charge battery 2 PV only It is only allow PV power to charge battery 3 None It is not allowed to charge battery no matter it s PV power or grid Load supply source When PV power is available 1 1 PV 274 Battery 3 Grid PV power will provide power to the load first If it s not sufficient battery power 24 will provide power to the load When battery power is running out or not available grid will back up the load 2 1 PV 2 Grid 3 Battery PV power will provide power to the load first If it s not sufficient grid will provide power to the load If grid is not available at the same time battery power will back up When PV power is not available 1 1 Grid 2 Battery Grid will provide power to the load at first If grid is not available battery power will provide power backup 1st Battery 2 Grid Battery power will provide power to the load at first If battery power is running out grid will back up the load NOTE This option will become ineffective during AC charging
23. V1 input power PV2 input power Today This month This year E E E ee EU JA ee O A A ee S CA E A A A 8 Si 2 8 8 O A A A O O rd O O E oe Ue 2015 01 19 Diagram 4 2 1 Power flow It will display real time power flow with running color bar Power flow chart includes solar module icon solar inverter icon battery icon load icon and the utility icon Solar module icon presents the numbers of MPP tracker defined by solar inverter NOTE Battery and load icon will not present only when this device is set as grid tie mode There are three operation modes can be set up via this software Below is operation power flow description Operation mode setting can be configured in MyPower Management Please refer to 4 2 1 section e Grid tie Operation When this device is successfully connected to the grid there will be power flow animation from solar module icon to the utility icon SolarPower will report and have animation during normal operation If any fault or abnormal occurs Power flow animation will stop and represent icon will flash e Grid tie with backup Operation There are three power sources in On grid with backup mode PV power battery power and utility power Charging mode Only PV power exists to charge battery There will be power flow animation from solar modules to the battery Line mode Utility power exists or is available during this mode All possible 11 power flows are described as below 1
24. ailable Mode Standard YDE0126 e Nominal output voltage 230 e Nominal output frequency 40 Setting PY energy supply priority setting Grid Only Configuration details Charging source Load supply source P is available Load supply source PW is unavailable al m al Lal Allow AC charging duration 00 00 00 00 00 00 Means AC charger operates all time AC Output ONJOff Timer MMS 00 00 00 00 means AC Output timer function disable Apply Close l 28 Off Grid Off Grid I Mode Gitte win backup Cree YDE0126 Nominal output voltage 230 e Nominal output frequency 50 e Setting PY energy supply priority setting Off Grid 1 Priority 1st Load gt 2nd Battery Grid relay is connected in inverter mode Configuration details Charging source PV or Grid PY will charge battery first If PY power is loss grid will charge battery Load supply source PV is available PW Battery Grid v Priority 1st PY gt 2nd Battery gt 3rd Grid Load supply source PY is unavailable Battery Grid Priority 1st Battery gt 2nd Grid E lt lt This option is ineffective during of AC charging PP When battery voltage lt ME y the Ac starts charging E E B z Allow AC charging duration 00 00 E 00 00 00 00 Means AC charger operates all time AC Output ON Off Timer 00 00 ee l 00 00 e 00 00 00 00 means AC Output timer function disable Apply Clase PV energy su
25. ation or click shortcut icon a Refer to Diagram 4 21 e Product information including Model type Topology Main CPU processor version Secondary CPU processor version Output phase Nominal input voltage Nominal output voltage and so on 44 e Rated information including nominal output power min AC input voltage max AC input voltage min AC input frequency max AC input frequency max PV input current rated battery voltage nominal grid connected voltage nominal grid connected frequency Nominal grid connected current max input current for each PV and number of maximum power tracing units These listed information will be different based on different mode setting for inverter Purchasing information including Purchasing date Warranty for device Device P N and so on Product Information Model type Hybrid Nominal input voltage 230 0 V Topology transformerless Nominal output voltage 230 0 V Main CPU processor version 00001 01 Number of batteries 4 Secondary CPU processor version 00001 01 Nominal battery voltage 48 0 V Output phase 3 3 Rated information Nominal output power 10000 W Nominal grid voltage Min AC input voltage 170 0 VW Nominal grid frequency Max AC input voltage 280 0 Nominal grid connected current Min AC input frequency 40 0 y Max PY input current Max AC input frequency 55 0 H Rated battery voltage Purchasing information Purchasing date 2015 01 19 Warranty for device
26. ceivers list Mote Apply Diagram 4 7 NOTE It s required to plug in GSM Modem if sending SMS to mobile phone 17 4 1 4 E mail It is allowed to send an alarm mail by SMTP server For the event receiving list please configure it in Event Action column refer to section 4 1 5 To use this function e mail service must be configured correctly All values in this function page are default empty This action can t be executed without SMTP information e mail account and password Besides the sender account should be allowed for SMTP POP3 forwarding Step 1 Select SolarPower Configuration gt gt E mail Refer to Diagram 4 8 SMTP server setting SMTP server smtp testcom send from account amp testcom Username account Password Authentication needed Password 08 Receivers list test test com test testcom Add Delete Mote Click Test button to checkifthe transmission is successtully Test Apply i Close Diagram 4 8 Step 2 Enter SMTP server Port Sender E mail address User name and password Click checkbox of Password Authentication needed for password verify NOTE If using Exchange Server for mailbox system it s required to configure Exchange server domain name in SMTP sever and click checkbox of Exchange server Then click Apply button Step 3 Enter correct e mail accounts in E mail column Then click Add button to add into receivers list To
27. charge battery first Only until PV power is not available grid will charge battery 2 PV only It is only allow PV power to charge battery 3 None It is not allowed to charge battery no matter it s PV power or grid NOTE It s allowed to set up AC charging duration Load supply source When PV power is available 1 PV 2 Battery 3 Grid PV power will provide power to the load first If it s not sufficient battery power will back up the load Only after battery power is running Grid will back up the load When PV power is not available 1 1 Grid 2 Battery Grid will provide power to the load at first If grid is not available battery power will provide power backup 2 1 Battery 2 Grid Battery power will provide power to the load at first If battery power is running out grid will back up the load NOTE This option will become ineffective during AC charging time and the priority will automatically become 1 Grid and 2 Battery order Otherwise it will cause battery damage AC Charging Setup When selected after battery voltage is lower than setting xx x V AC will start to charge battery When this condition is selected it s allowed to enter setting voltage Otherwise it s impossible to enter any values Allow AC charging duration It s a period time to allow AC grid to charge battery When the duration is set up as 0 00 00 00 it means no time limitation for AC to charge battery AC ou
28. delete e mail account simply select accounts from Receivers list and click Delete button Step 4 Click Apply button to save all changes The Test button can be used to send a test e mail to all receivers to confirm correct operation When the test e mails are successfully sent to specific recipients it will pop up a successful message on operated PC Otherwise it will pop up a failure dialog to indicate there is an error for parameter setting 4 1 5 Event action It s to configure response actions for events occurring in solar inverter There are four response actions provided after events occur 1 Event record It will record event to data log in software after events occur This event is default selected 2 Warning message s It will send event message to system tray 3 SMS It will send event message to specific mobile phone numbers after events occur 4 E mail It will send event e mail to assigned e mail accounts after events occur Step 1 Select SolarPower Configuration gt gt Event actions Refer to Diagram 4 9 Step 2 Select action methods by clicking checkbox Step 3 Click Apply button to save all configurations Event Fault DC bus voltage exceeds the upper threshold E 1002 DC bus voltage falls below the lower threshold sendbyw Event record 1003 DC bust voltage sof start is time out Warning messagers 1004 Inverter sofi start is time out 1005 Faut An Inverter overcurrent event is d
29. e defaults Refers to Diagram 4 12A for grid tie with backup mode and Diagram 4 12B for Off Grid mode Min grid connected voltage Max grid connected voltage Min grid connected frequency Max grid connected frequency Max grid connected average voltage Min PY input voltage Max PY input voltage Min MPP voltage Max MPP voltage Max charging current Floating charging voltage Bulk charging voltage voltage Battery cutoff discharging voltage when Grid is available Battery re discharging voltage when Grid is available 300 Y Battery cutoff discharging voltage when Grid is unavailable Goo Y Battery re discharging voltage when Grid is Unavailable 350 Y Start LOO screen saver after A This operation will also clear all existed data stored here and shall be used cautiously Restore to the defaults Diagram 4 12A Grid tie with backup Min AC input voltage Max AC input voltage Min AC input frequency hax AC input frequency Min PY input voltage Max PY input voltage Min MPP voltage hax MPP voltage 60 0 54 0 56 0 r Ay al 52 5 300 900 350 Max charging current Floating charging voltage Bulk charging voltage w voltage Battery cutot discharging voltage when Grid is available Battery re discharging voltage when Grid is available Battery cutot discharging voltage when Grid is Unavailable Battery re discharaina
30. ear rr Browse Diagram 4 18 4 3 3 Fault data log Fault data log is to record last data before any fault occurs in solar inverter Select View gt gt Fault data log or click shortcut iconii A Refer to Diagram 4 19 gt Export excel When selected and click Export it will save listed table to local PC in xls file gt Export Click Export button to save listed table to local PC in PDF file gt Delete Select specific data and click Delete button to delete the record gt Delete all Click Delete All button to delete all records on the listed table Device 000000000000 PA Time period 2014 10 24 fe 2014 10 24 fj Browse Export excel Input date Fault messagelPy MANULA olt JP 2 input volt Grid voltage R Grid voltage S Grid voltage T Grid frequency Battery voltage Charging curr Grid output vo Grid output vo Grid output vo Load frequenc 2014 10 24 Leakage cur AL wed 0 0 0 0 0 0 0 0 hag 0 0 0 0 0 0 E 4 Current san 4 201 4 10 2 2014 10 24 Leakage cur 2014 10 24 Current sam 71 8 2014 10 24 g 2014 10 24 Current san 201 4 10 24 15 0 Total 11 rowts Export Delete Delete all Close Diagram 4 19 43 4 3 4 Event log It s to record history events Users can browse event list according to date It lists all detailed information and statistics for history events Refer to Diagram 4 20
31. etected as 1006 Over temperature alarm 1007 An relay failure eventis detected 1008 DC component in the output current exceeds the 1009 PY input voltage exceeds the Upper threshold 1010 Auxiliary power failed 1011 Faut an PY input overcurrent event is detected Phone No 1012 Leakage current exceeds the allowable range 1013 PY insulation resistance is too low 1014 Inverter DC component exceeds the allowable ran 1015 A difference occurred in the readings from the mai 1016 Leakage current CT failed 1017 communication with the main and secondary con 1018 Faut An communicating error occurred in the handsha 1014 Mo electrical ground a Apply Close 1020 Discharge circuit fault i f 10 74 FP To AA O ASA Feil cl Diagram 4 9 NOTE1 When any modification is applied in receiver list of SMS or e mail columns it s necessary to refresh the event action page to reload the updated receiver list NOTE2 Event list may be different based on different types of solar inverters 19 4 1 6 Com port Plug And Play Setting To real time monitor solar inverter device the software will scan each com port anytime In this way it will occupy com port This function will release some com ports which are not connected to solar inverters To avoid any improper operation in used com ports will display in disabled grey texts Users can select Allow scanned to re scan or No scanning to release com
32. evice control View Language Help m m i ET F FS E y Administrator Monitored device USB14200000_00000000000000 System time 2015 01 19 16 33 42 Temperature 37 0 C ls Pan cun bin nb vcn vol corp Basic information USB14200000_0000000000000 PV1 input voltage AC output active power R Grid tie with backup PV2 input voltage AC output active power S i Grid voltage R AC output active power T s yo Grid voltage S Total AC output active power A LOAD Grid voltage T AC output apparent power R Grid frequency AC output apparent power Load level AC output apparent power T Charging current J Total AC output apparent power Battery voltage Inner temperature Battery capacity Max component temperature Power information PV1 input power PV2 input power Today This month This year 0 0 0 0 0 0 10 S O GEES Y SS E O 2015 01 19 Diagram 4 23 4 5 Language Currently this software offers 13 languages for selection J Chinese Simplified Chinese Traditional English German Italian Polish Portuguese Russian Spanish Ukrainian French E ey ESCO eC Turkish l Japanese When first using the software it will display proper language according to OS language 4 6 Help e About Click Help menu and select About item It represents the copyright information about software e Help Click Help menu and select Online help item It will ope
33. ging voltage when Grid is unavailable It s to set up battery re discharging voltage when grid is not available Battery temperature compensation It s to adjust charging voltage based on 2V cell when battery temperature is changing between 0 50 C All charging settings are based on 25 C If setting battery temperature compensation as 5mV charging voltage will be reduced by the following formula T 25 Battery voltage with serial connection 2 5mV 36 For example 3 phase inverter with 48VDC under 30 C environment 30 25 48VDC 2 V cell 5 mV 600mV Then when battery temperature is higher 5 C charging voltage will be reduced 600mV Vice versa Feeding grid power calibration This adjustment allows to calibrate inverter output power to meet demand power for connected load and avoid overflow to the grid Max battery discharge current in hybrid mode It allows to set up maximum battery discharge current in grid tie and grid tie with backup mode operation Mute Buzzer alarm If it s activated when fault or warning occurs it will not sound Vice versa Mute the buzzer in the Standby mode If it s activated the buzzer will not sound when the device is in the standby mode Vice versa Mute the buzzer in battery mode If it s activated the buzzer will not sound when the device is in the Battery mode Vice versa Generator as AC source If enabled the unit is able to accept generator as AC power so
34. ick Next button Refer to the following diagram 2 4 Please choose a destination folder for this installation Groose Srortcue older rrelstallatiorn Sra Irisstenllirigy Install Corrpleta Where Would You Like to Install C 450larPower Restore Default Folder Diagram 2 4 Step 5 Choose the shortcut folder and click Next button Refer to the following diagram 2 5 Where would you like to create product icons Fan a rrelsiallatorn SUr a Instale In the Start Menu Install Corrpleta J On the Desktop E In the Quick Launch Bar A J x Co Don t create icons Create Icons for All Users Cancel Previous Diagram 2 5 Step 6 It will display the software summary before installation Click Install button to start the installation and refer to Diagram 2 6 Please Rewew the Following Before Continuing Product Name SolarPower Install Cormplete C SolarPower Shortcut Folder C Wsers Acdministrator App lata Roaming sMicrosotVvindows Menu Programs solarPower Disk Space Information for Installation Target Required 143 517 706 bytes lll Cancel Previous Diagram 2 6 Step 7 Installing refer to Diagram 2 7 Install Corrpleta Cancel Diagram 2 7 Step 8 Click Done button to confirm the installation completely Refer to Diagram 2 8 Congratulations SolarPower has been successfully installed to CisolarPower Press Done to quitthe
35. ient PV power will charge battery and provide power to load There will be power flow animation from PV module icon to battery and load icons If PV power is not sufficient PV power and battery power will provide power to the load at the same time There will be power flow from PV module and battery icons to load icon Fault mode When a fault occurs in solar inverter the icon of solar inverter will flash until the fault is solved e Off Grid Operation There is no power feed in to the grid Utility or generator becomes one of power sources Bypass with PV charging mode If PV power is sufficient it will charge the battery and AC power will provide power to load One power flow animation is from PV module icon to battery icon and another one is from utility icon to load icon Bypass with AC charging mode If PV power is insufficient AC power will 12 2 charge the battery and provide power to load There will power flow animation from utility icon to battery and load icons Inverter mode Utility power is not available or not connected All possible power flows are described as below 1 If PV power is not available battery power will provide power to the load There will be power flow animation from battery icon to load icon 2 If PV power is available and sufficient PV power will charge battery and provide power to load There will be power flow animation from PV module icon to battery and load icons 3 If PV
36. information PV1 input power PV2 input power Today This month This year 8 8 CF 8 8 88 ee Ue 8 A SD 0 0 0 0 0 0 0 0 1 23 4 5 6 7 8 9 W iW 12 13 WwW 1S 16 1 WW WY 2 21 22 23 2015 01 19 Diagram 4 1 A Function Menu offers complete tool set for navigating and setting the GUI B Shortcut Menu provides short cuts to access more commonly used functions C Device Navigation indicates all detected devices D Current Monitoring Information displays User ID monitored device ID time and temperature E Main Client Area This function is to display power flow basic information and power generation of current monitored solar inverter Refer to Diagram 4 2 10 SolarPower configuration Device control View Language Help mn m R E f Fa Administrator Monitored device USB14200000_00000000000000 System time 2015 01 19 16 21 48 Temperature 38 0 C a pan cun bin nb vcn vol corp lasic information USB14200000_00000000000000 PV1 input voltage AC output active power R Grid tie with backup PV2 input voltage y AC output active power S Grid voltage R AC output active power T Grid voltage S Total AC output active power Grid voltage T AC output apparent power R Grid frequency AC output apparent power Load level AC output apparent power T Charging current j Total AC output apparent power Battery voltage inner temperature Battery capacity Max component temperature M Power information P
37. l output synchronization data Select device e There are two patterns to sync data Synchronize all data It will save data of selected devices to the database immediately Synchronize data for selected date It will save data of selected devices to the database during indicating period NOTE No matter it s automatic or manual sync this action is only applied to unsaved data before If users want to update output data during specific time period then please 39 delete the data record of this period from power generation log first 4 2 5 Real time control It s to real time control AC output and activate Li Fe battery Select Device control gt gt Real time control Refer to Diagram 4 14 Activate Li Fe Battery now Yes O Activate Li Fe battery while commissioning is selected in parameter setting Al output willbe cut of when this action is executed Diagram 4 14 e AC output control Turn on or turn off AC output immediately when clicking Apply button e Activate Li Fe Battery now To activate Li Fe battery when clicking Yes button Please be aware AC output will be cut off when this action is executed if Activate Li Fe battery while commissioning is selected in parameter setting AC output will be restored after this action is executed completely 4 3 View 4 3 1 Power generation log data This function is to browse calculate or delete power generation data in the datasheets or chart for
38. mats o Datasheets Select View gt gt Power generation log data gt gt Datasheets or click shortcut ol Refer to Diagram 4 15 Select browsed device and period Then click Browse to get result 40 gt Export excel When selected and click Export it will save listed table to local PC in xls file gt Delete Select specific data and click Delete button to delete the record gt Export Click Export button to save listed table to local PC in PDF file Device OO0000000000000 Period NO Year E 2 014 yyy 2 014 eg Browse Export excel Year Output power 2014 E Total power generation 0 007 kWh Export Close Diagram 4 15 e Charts Select View gt gt Power generation log data gt gt Charts Refer to Diagram 4 16 Select browsed device and period Click Browse to get result Device soooo00000000 PA PeriodNO Year 2011 Diagram 4 16 41 4 3 2 Data This function is to browse the working data of solar inverter saved in datasheets or chart formats eo Datasheets Select View gt gt Data gt gt Datasheets or click shortcut icon Refer to Diagram 4 17 Select browsed device and period to display in the screen Click Browse to get result gt Export excel When selected and click Export it will save listed table to local PC in xls file Export Click Export button to save listed table to local PC in
39. n Inverter mode That means the transfer time from inverter mode to battery mode will be less than 15ms Besides it will avoid overload fault because grid can supply load when connected load is over 10KW 30 Battery charging source 1 PV or Grid If there is remaining PV power after supporting the loads it will charge battery first Only until PV power is not available grid will charge battery 2 PV only It is only allow PV power to charge battery 3 None It is not allowed to charge battery no matter it s PV power or grid NOTE It s allowed to set up AC charging duration Load supply source When PV power is available 1 PV 2 Grid 3 Battery PV power will provide power to the load first If it s not sufficient grid will provide power to the load If grid is not available at the same time battery power will back up When PV power is not available 1 1 Grid 2 Battery Grid will provide power to the load at first If grid is not available battery power will provide power backup 2 1 Battery 2 Grid Battery power will provide power to the load at first If battery power is running out grid will back up the load NOTE This option will become ineffective during AC charging time and the priority will automatically become 1 Grid and 2 Battery order Otherwise it will cause battery damage e Off Grid III Mode late win backup Sie Off Grid Standard VDE0126 w Nominal output voltage 230
40. n the help manual Before operating software please read manual carefully 47
41. ng the remaining power will charge battery 25 NOTE The max feed in grid power setting is available in parameter setting Please refer to section 4 2 2 Battery charging source 1 PV and Grid It s allowed to charge battery from PV power first If it s not sufficient grid will charge battery 2 PV only It is only allow PV power to charge battery 3 None It is not allowed to charge battery no matter it s PV power or grid Load supply source When PV power is available 1 1 PV 2 Battery 3 Grid PV power will provide power to the load first If it s not sufficient battery power will provide power to the load When battery power is running out or not available grid will back up the load 2 1 PV 2 Grid 3 Battery PV power will provide power to the load first If it s not sufficient grid will provide power to the load If grid is not available at the same time battery power will back up When PV power is not available 1 1 Grid 2 Battery Grid will provide power to the load at first If grid is not available battery power will provide power backup 2 1 Battery 2 Grid Battery power will provide power to the load at first If battery power is running out grid will back up the load NOTE This option will become ineffective during AC charging time and the priority will automatically become 1 t Grid and 2 Battery order Otherwise it will cause battery damage 26 e Grid tie wi
42. nstall the software 4 1 3 SMS Setting It s for entering SMS receiver list In the event of an alarm occurring a message about Solar Inverter status will be sent to the specified users via mobile phone For the event receiving list please configure in Event Action column refer to section 4 1 5 Step 1 Choose SolarPower Configuration gt gt SMS Setting Refer to Diagram 4 5 Com port setting Com port COMMS Baud rate 1200 Receivers list 12345677708 Mote Click Test button to checkif the transmission is successfully Test Apply i Close Diagram 4 5 Step 2 Select communication port and baud rate Step 3 Enter mobile phone numbers in Phone no column and click Add button to add phone no in Receivers List To delete numbers simply select phone no from Receivers list and click Delete Step 4 Click Apply button to save all changes The Test button can be used to send a test SMS to confirm the correct operation If all parameters are set up correctly system will send a test message to all receivers and pop up a successful message Refer to Diagram 4 6 Otherwise it will pop up a failure dialog to indicate there is an error for parameter setting Refer to Diagram 4 7 SMS Setting Com port setting Com port COMMS Baud rate MANN Receivers list Mote Apply Diagram 4 6 SMS Setting Com port setting Com port COMMS Baud rate HAMI Re
43. ports based on their requirements Step 1 Select SolarPower configuration gt gt Com port plug and play setting Refer to Diagram 4 10 X Refresh coma Allow scanned No Scanning Apply Lised Diagram 4 10 Step 2 Click Refresh to reload the statuses of all com ports Step 3 Click No scanning to stop scanning on this com port Click Allow scanned to start scanning on this com port 20 4 2 Device control 4 2 1 MyPower Management It is to set up inverter operation mode and personalized interface Select Device Control gt gt MyPower Management Refer to below diagram Standard VYDE0126 e Nominal output voltage 230 Nominal output frequency 50 Setting PY energy supply priority setting Grid Tie with Backup I Priority 1st Battery gt 2nd Load gt 3rd Grid Configuration details Charging source PY and Grid e PY charging first If PY power is not sufficient PY and grid will charge battery together F Allow to feed in to the Grid Load supply source PV is unavailable Grid Battery Load supply source PY is available PY Grid Battery Priority 1st PY gt 2nd Grid gt 3rd Battery riority 1st Grid gt 2nd Battery z gt Eee Se ene ni gatan m Allow battery to feed in to the Grid when PY is unavailable MM vihen battery voltage lt MIES Y the AC starts charging X r ee m LEE 2 F Allow AC charging duration OO 00 me 00 00 00 00
44. power is not sufficient PV power and battery power will provide power to the load at the same time There will be power flow from PV module and battery icons to load icon Standby mode Only PV power is available There is no load connection and no utility and battery power available during this mode Standby with PV charging mode PV power will charge the battery There will be power flow animation from PV module icon to battery icon Standby with AC charging mode AC power will charge the battery There will be power flow animation from utility icon to battery icon Fault mode When a fault occurs in solar inverter the icon of solar inverter will flash until the fault is solved Basic Information This page is to display current working data for monitored inverter The major displayed information includes grid voltage grid frequency PV input voltage output current and so on 3 Power Information Power information displays real time PV input power and power generation data based on current date current month and current year Power generation bar chart Display hourly power generation on current date when selecting per hour Display daily power generation in current month when selecting daily Display monthly power generation in current year when selecting monthly L Display annual power generation so far this year when selecting annua NOTE This screen may be different for different types
45. pply priority setting 1 Load 2 Battery PV power will provide power to the load first and then charge battery Feed in to the grid is not allowed under this mode At the same time the grid relay is connected in Inverter mode That means the transfer time from inverter mode to battery mode will be less than 15ms Besides it will avoid overload fault because grid can supply load when connected load is over 10KW Battery charging source 1 PV or Grid If there is remaining PV power after supporting the loads it will charge battery first Only until PV power is not available grid will charge battery 2 PV only It is only allow PV power to charge battery 3 None It is not allowed to charge battery no matter it s PV power or grid Load supply source When PV power is available 1 1 PV 274 Battery 3 Grid PV power will provide power to the load first If it s not sufficient battery power will provide power to the load When battery power is running out or not available grid will back up the load 2 1 PV 2 Grid 3 Battery 29 PV power will provide power to the load first If it s not sufficient grid will provide power to the load If grid is not available at the same time battery power will back up When PV power is not available 1 1 Grid 2 Battery Grid will provide power to the load at first If grid is not available battery power will provide power backup 2 1 Battery 2 Grid Battery powe
46. r will provide power to the load at first If battery power is running out grid will back up the load NOTE This option will become ineffective during AC charging time and the priority will automatically become 1 Grid and 2 Battery order Otherwise it will cause battery damage Off Grid II Standard DE01 26 Nominal output voltage 230 Nominal output frequency 50 Setting PY energy supply priority setting EA Priority 1st Battery gt 2nd Load Grid relay is connected in inverter mode Configuration details Charging source PV or Grid e PY will charge battery first If PY power is loss grid will charge battery Load supply source PV is available P Grid Battery e Priority 1st PY gt 2nd Grid gt 3rd Battery Load supply source PY is unavailable Grid Battery BEEEES SHS Priority 1st Grid gt 2nd Battery MM unen battery voltage MIES Y the AC starts charging A A 2 uy lz a T 5 Allow AC charging duration OO 00 mee ESO 00 00 00 00 Means AC charger operates all time AC Output ON Off Timer 00 00 pee i 00 00 tee 00 00 00 00 means AC Output timer function disable Apply i Close PV energy supply priority setting 1 Battery 2 Load PV power will charge battery first After battery is fully charged if there is remaining PV power left it will provide power to the load Feed in to the grid is not allowed under this mode At the same time the grid relay is connected i
47. ry Grid will provide power to the load at first If grid is not available battery power will provide power backup 2 1 Battery 2 Grid Battery power will provide power to the load at first If battery power is running out grid will back up the load NOTE This option will become ineffective during AC charging time and the priority will automatically become 1 Grid and 2 Battery order Otherwise it will cause battery damage e Grid tie with backup II Mode Grid tie with backup PORO O Standard vDE0126 BM Nominal outputvoltage 230 PM Nominaloutputfrequency 50 5A Setting PY energy supply priority setting Grid Tie with Backup ll m Priority 1st Load gt 2nd Battery gt 3rd Grid Configuration details Charging source PV and Grid v PY charging first If PY power is not sufficient PY and grid will charge battery together PP Allow to feed in to the Grid coad suppisource EN ie unawallanlo Baten Gna EE battery to feed in to the Grid when PY is available Load supply source PV is available PW Battery Grid Priority 1st PY gt 2nd Battery gt 3rd Grid jority 1st Bz gt 2nd Gri R A ese PM Allow battery to feed in to the Grid when PY is unavailable This option is ineffective during of AC charging PA When battery voltage O aH the AC starts charging E Allow AC charging duration OO 00 me E 00 00 00 00 Means AC charger operates all time AC Output ON Off
48. s established successfully e Max PV input voltage The acceptable high voltage point for PV terminals when grid connection is established successfully e Min MPP voltage The acceptable low voltage point from solar module 35 Max MPP voltage The acceptable high voltage point from solar module Max charging current The acceptable high charging current point Max AC charging current The maximum acceptable charging current from AC If this AC charging current is higher than max charging current max charging current will be set up as real charging current Bulk charging voltage C V voltage Please check battery spec to set up this figure Floating charging voltage Please check battery spec to set up this figure The curve of Bulk charging voltage C V voltage and Floating charging voltage are listed as below U Bulk Voltage Float Voltage Bulk 3 Absorption Floating gt time gt time Start LCD screen saver after The maximum duration time to activate LCD backlight Battery cut off discharging voltage when Grid is available It s to set up battery cut off discharge voltage when grid is available Battery re discharging voltage when Grid is available It s to set up battery re charging voltage when grid is available Battery cut off discharging voltage when Grid is unavailable It s to set up battery cut off discharging voltage when grid is not available Battery re dischar
49. th DocumentsiStorrmiupdate zip B rowse Prepare for upgrade Upgrade Diagram 3 6 3 4 Icon and Software Status e When connecting devices and Bl will rotate as an animation e When receiving warning message with devices connected will flash for reminder e When receiving warning message without devices connected BA will flash for reminder NOTE Refer to Diagram 3 7 for warning message board Users can check message board for event list 8 31 09 18 27 6 31 09 18 23 Battery disconnected Diagram 3 7 3 5 Open Monitor Click Open Monitor to enter main screen of this software 3 6 Exit Click Exit to exist service application 4 SolarPower GUI Interface SolarPower GUI Interface has five sections as marked in the illustration below Administrator Monitored device USB14200000_00000000000000 System time 2015 01 19 16 21 48 Temperature 38 0 C ls pan cun bin nb vcn vol corp lasic information USB14200000_00000000000000 PV1 input voltage AC output active power R Grid tie with backup PV2 input voltage j AC output active power S Grid voltage R AC output active power T Grid voltage S Total AC output active power Grid voltage T AC output apparent power R Grid frequency AC output apparent power S Load level AC output apparent power T Charging current Total AC output apparent power Battery voltage y inner temperature Battery capacity Max component temperature rr Power
50. th backup IV Users are only allowed to set up peak time and off peak electricity demand Mode _ Grid tie with backup Gaa Oren Standard voe0126 M Nominal output voltage 230 e Nominal output frequency 50 e setting PY energy supply priority setting Grid Tie with Backup y Peak time Priority 1st Load gt 2nd Battery gt 3rd Grid Off Peak time lt Priority 1st Battery gt 2nd Load gt 3rd Grid gt Configuration details Charging source Peak Of Peak Grid Electricity Demand Peak time lt P power charge battery gt Load supply source PV is available Peak Off Peak Grid Electricity Demand e Peak time lt Priority 1st PY gt 2nd Battery gt 3rd Grid gt Off Peak time lt Priority 1st PY gt 2nd Grid gt 3rd Battery Load supply source PV is unavailable PeakfOff Peak Grid Electricity Demand e Peak time Priority 1st Battery gt 2nd Grid Off Peak time Grid Only gt MM yhen battery voltage lt aH Y the AC starts charging Ld Off Peak duration 00 00 wes 04 00e 00 00 00 00 Means AC charger operates all time AC Output ON Off Timer 00 00 me l 00 00 mee 00 00 00 00 means AC Output timer function disable Apply Close Working logic under peak time PV energy supply priority 1 Load 2 Battery and 3 Grid PV power will provide power to the load first If PV power is sufficient it will charge battery next If there is remaining PV power left it will feed in to
51. tput ON Off Timer Set up on off time for AC output of inverter If setting it as 00 00 00 00 this function is disabled Allow to charge battery This option is automatically determined by setting in Charging source It s not allowed to modify here When NONE is selected in 32 charging source section this option becomes unchecked as grey text Allow AC to charge battery This option is automatically determined by setting in Charging source It s not allowed to modify here When Grid and PV or Grid or PV is selected in charging source section this option is default selected Under Grid tie mode this option is invalid Allow to feed in to the Grid This option is only valid under Grid tie and Grid tie with backup modes Users can decide if this inverter can feed in to the grid Allow battery to discharge when PV is available This option is automatically determined by setting in Load supply source PV is available When Battery is higher priority than Grid in Load supply source PV is available this option is default selected Under Grid tie this option is invalid Allow battery to discharge when PV is unavailable This option is automatically determined by setting in Load supply source PV is unavailable When Battery is higher priority than Grid in Load supply source PV is unavailable this option is default selected Under Grid tie mode this option is invalid
52. urce When this function is enabled it s recommended to enable Wide AC input voltage range item Activate Li Fe battery while commissioning If yes is selected Li Fe battery will be activated while commissioning Wide AC input range If disabled the acceptable AC input voltage range will be determined by setting voltage between min grid connected voltage and max grid connected voltage and setting frequency between min grid connected frequency and max grid connected frequency If enabled AC input voltage range will become 170V 280V The acceptable frequency range become 40Hz 55Hz for 50 Hz system and 55Hz 65Hz for 60 Hz system When either AC input voltage or AC input frequency is beyond the grid connected setting range it s not allowed to feed in back to grid At this time it s only available to provide power to loads or charge battery When float charging current is less than X A and lasts T Min then charger is Off When battery voltage is less than Y V then charger is on again System time It presents the device time zone Any modification may effect the calculation of power generation Please conservatively make any change NOTE All parameter setting should be made at standby mode a7 4 2 3 Restore to the defaults This function will restore all settings to the default and clear all data in database Therefore please conservatively execute this function Select Device control gt gt Restore to th
53. voltage when Grid is unavailable Start LCD screern saver after A This aperation will also clear all existed data stored here and shall be used cautiously Restore to the defaults Diagram 4 12B Off Grid 60 0 54 0 56 0 NOTE This screen may be different for different settings of solar inverters 38 4 2 4 Output synchronization data This function will retrieve saved data in selected solar inverter units to re save in the database It can be saved either automatically or manually Select Device control gt gt Output synchronization data Refer to Diagram 4 13 Period NO Date Time synchronization du Device Automatic output synchronization data daily 17 34 90000000000000 Device J 9000000000 e Synchronization period J Daily Weekly J Monthly Time 17 34 aa Synchronization duration 1 P Davis Delete Manual output synchronization data H Device J 9000000000 Synchronization pattern 0 Synchronize all data J Synchronize data for selected date Time period ln i as q O O S O OS Diagram 4 13 Automatic output synchronization data Select device Set frequency daily weekly monthly and time to automatically sync output data Add schedule into calendar by clicking Add button Every device is only applied one sync schedule Delete schedule by selecting one schedule from the list and clicking delete button to remove Manua