1. Qeeemblod Water stoP 206 Patent pending USER S MANUAL Edition September 2006 Vers 02 ASSEMBLAD S r l Technical office Automotive Division Marte C anno2006 Manuali Operativi Servizio Vari M206 GB 02 doc amp pdf Assemblad S r l Manuale uso manutenzione e servizio M206 GB 02 doc pdf 1 Connection to the gas analyzer Put vertically the Water stoP 206 as indicated in Fig 1 near the input connection gas of the gas analyzer that we want to protect Connect with adequate pipe the gas analyzer to the Water stoP 206 upper connection Ref 01 Output to ANALYZER Connect the gas probe to the lower part of the Water stoP 206 Ref 02 Input from EXHAUST Fig 1 Main components of Water stoP 206 The Water stoP 206 is supplied with the attacks connections for rubber tube int 6 milimeter 01 Ref and 02 Ref standard version other connections are supplyed upon request at the moment of the order fast connection available for plastic tubes etc always with thread attack from 1 8 of inch Note We suggest to interpose between the input Ref 02 and the gas probe a paper filter or a filter condenses in order to eliminate the rough parts from the exhaust or the surrounding atmosphere that for effect of the aspiration of the analyzer pump could penetrate inside of the Water stoP 206 and compromise the airtight Assemblad S r l 50013 Campi Bisenzio
2. Firenze Italy 2 http www assemblad it E mail info assemblad it Assemblad S r l Manuale uso manutenzione e servizio M206 GB 02 doc pdf 2 Operation We remember you that the Water stoP 206 must be placed in a vertical position as indicated in Fig 1 and we strongly suggest to fix it to the analyzer or to the support trolley using i e a biadhesive tape or coupling etc When the analyzer through the probe gas aspirates only gas from the exhaust the Water stoP 206 remains practically inactive and it does not interfere with the flow of gases If together with the gas also any liquids arrive or even only condensed water the floater of the Water stoP 206 goes up till contacting with the gasket and closing every flux of gas and water to the analyzer When the Water stoP 206 stops the analyzer in put in condition of Low flow or No flow or Error and the anomaly will alarm the operator and stopping the aspiration pump Then to operator must stop the analyzer pump remove the Water stoP 206 from the analyzer and expel all the water that has been stopped inside Normally it is necessary to remove the Water stoP 206 from the analyzer because the depression created inside maintains closed the system of the Water stoP 206 Every time after the Water stoP 206 is activated it is suggested to remove also the probe gas and to the eliminate the water eventually still inside Note 8 Inner cap
3. acity and or inner Volume of operation is approximately 30 millilitre of water Note Some traces of water or gas could continue towards the analyzer if the inner parts of the Water stoP 206 have not been protected and or maintained clean however the amount in transit well be derisory and however dispose of from the system of water drainage previewed on all the analyzers In this case we suggest to clean up or to replace eventual parts damaged of the Water stoP 206 3 Spare parts for Water stoP 206 Ref 01 02 P N 970 000260 Connection for rubber tube int 6 millimetres supply standard Ref 01 02 P N 970 001010 Connection Super fast ext 6 millimetres on request Ref 03 P N 301 030200 Seal ring Ref 04 P N 692 004006 Floating ball Ref 05 P N 793 150080 ORing model OR 2037 use only with P N 970 000260 Ref 06 P N 793 150150 ORing model OR 3168 Ref 07 P N 301 030000 Transparent half side Assemblad S r l 50013 Campi Bisenzio Firenze Italy 3 http www assemblad it E mail info assemblad it Assemblad S r l Manuale uso manutenzione e servizio M206 GB 02 doc pdf 4 WARRANTY This device was built with care and carefully inspected before leaving the factory It is guaranteed for 18 months from the date of purchase The warranty covers any defects in materials The warranty does not cover damage caused by accidents negligence improper use non compliance with the
4. instructions Any return of goods must be authorized from Assemblad ASSEMBLAD disclaims any liability for damages and injuries caused even to third parties by an improper installation Further ASSEMBLAD disclaims any claim for damages from anyone due to a miss utilization of the device for any reason The warranty shall immediately become invalid if the device shows any signs of tampering The exclusive court of jurisdiction for any disputes arising from the application and or interpretation of this warranty is the Court of Florence Italy File Marte C anno2006 M206 GB 02 doc pdf COPYRIGHT by ASSEMBLAD S r l Via Marzabotto 4 50013 Campi Bisenzio Firenze ITALY Tel 39 055 890485 Fax 39 055 890496 All the rights are reserved Any reproduction is not admitted without Assemblad written authorization are Registered Trademark from Assemblad Assemblad S r l 50013 Campi Bisenzio Firenze Italy 4 http www assemblad it E mail info assemblad it

Download Pdf Manuals

image

Related Search

Related Contents

Cobra CXT-225 two-way radio  intext:Bedienungsanleitung filetype:pdf  Dialogic D/4PCIUF Combined Media Board  myPilot™  Rosemount Serie 3051S Skalierbare Druck-, Durchfluss  Manuale di istruzioni - Panasonic Electric Works  ROCKY HOT WATER HEAT PUMP  VueLink for SAP PLM User Manual  L-3 Guardian® was develope - L  

Copyright © All rights reserved.
Failed to retrieve file