1. USER S MANUAL AURATON 1300 I INTRODUCTION This thermostat is designed to be used with electric gas or oil heating system Appearance Sensor Position Screen Up Down Button ON OFF Switch Reset LCD LCD Temperature Temperature Set Icon Low Battery Icon Heater On Icon Features Several useful functions and operating modes have been incorporated to adapt a variety of customer needs e Room Temperature Display e Heater Operation Mode e Low Battery Indicator e On Off Switch Il INSTALLATION Select a suitable location for the thermostat The location of the thermostat can greatly affect its performance If it is lacated at where circulate air cannot reach or exposed to direct sun light it will not adjust the room temperature properly To ensure proper operation the thermostat should be installed at an inside wall with freely circulating air Find a place where your family usually occupied Avoid close to some heat generating appliance e g TV heater refrigerator or exposed to direct sun light Do not install near a door where the thermostat will suffer from vibration For optimal operation choose a mounting location e About 1 5 meter above the floor in an area with good air circulation e Away from drafts of dead air sports air ducts radiant heat from the sun or appliances concealed pipes and chimneys Mounting e Mounting the thermostat onto the wall e Remov
2. e completely the front housing of the thermostat by loosening the screws at the bottom see picture The mounting SSS teers holes position as e Mark the holes position and align the wire coming from the wall in the hole beside the connectors see picture e Drill two holes and insert the plastic anchors carefully into the holes until they are flush with the wall e Fasten securely the thermostat to the wall with the two screws Connecting the Wires The AURATON 1300 thermostat can be used with single stage heating system Inside the thermostat three terminals which label COM common NC normal close and NO normal open would be found In most case COM and NO are used COM NO NC HEATER ae fe Temperature Span Span is the temperature difference between the turn ON and OFF temperature The factory pre set span is 0 5 C For example control temperature setting is 20 C The heater will be operated when the room temperature drops to 19 5 C and will be turned off when the temperature rises to 20 5 C Temperature Measurement HI will be shown when temperature is above 40 C and LO will be shown when temperature falls below 0 C Power Installation The thermostat is operated by two AAA 1 5V Alkaline batteries To power up the unit install the batteries and slide the ON OFF switch to ON position When power is supplied for the first time or reset button is pressed the display will show as foll
3. med temperature and the Heater On Icon will be displayed as shown Output On Delay For safety purposes the thermostat has an auto 20 seconds delay for heater to restart VI SPECIFICATIONS Physical Characteristics Size 98 W X 28 L X 73 H mm Material Polycarbonate PC Weight 98g battery not included Electrical Characteristics Power Source AAA 1 5V Alkaline battery x 2 Switching Relay Resistive load 5A at 250VAC Inductive load 3A at 250VAC Temperature Measuremen 0 40 C Temperature Accuracy 1 0 C Temperature Control 5 35 C Temperature Control Span 0 5 C Output On Delay 20 seconds Operating Temperature 10 C to 50 C non condensing Storage Temperature 30 C to 60 C Operating polluted condition Normal
4. ows I Leo If the display is different as shown use a fine probe such as straightened paper clip to gently push the reset button TEMPERATURE 22 CONTROL TEMPERATURE 20 C OUTPUT OFF IHI CONTROL TEMPERATURE At the normal operation mode the temperature could be set e Push a v button to view the setting temperaturewhich was set last time e When power up or reset the factory preset control temperature 20 C is shown e Hold button about 3 seconds and the temperature indicator will flash one time i gt C ml LG SET e Push button to increase or decrease thetemperature setting e Hold button to fast advances the adjustment rate e The unit will be back to normal operation mode automatically when no button is pressed about 10 seconds e Program temperature can only be set in the control temperature range from 5 C to 35 C not wrap around at two ends e When pushing the a button to increase the temperature to 35 C it is no further increment Likewise when pushing w button to decrease the temperature to 5 C it is no further decrement IV LOW BATTERY OPERATION When the voltage of the battery decrease to certain level the LCD will be blank In this case the batteries should be changed as soon as possible to avoid any data loss V HEATER OPERATION Heater On Operation The heater will be turned on when the room temperature is lower than the program

Download Pdf Manuals

image

Related Search

Related Contents

manual do proprietário  Eglo 90119A Instructions / Assembly  取扱説明書  OPERA TION AND MAINTENANCE  Differential item functioning analysis system User`s Manual  Grizzly G1067Z Lathe User Manual  Manual de Utilização do Site Manager  施工業者向け  取扱説明書[ES-ED91]  2 - ACR  

Copyright © All rights reserved.
Failed to retrieve file