Home

SD9 Getting Started Manual - Version B

image

Contents

1. 1 Rac i 2R 2 3 t 5 j 7 B Mic 1hM62 tMic4d 1Me5 1hM6B dhie TMC 8 CK HAD 1 Mic 1M5 1MKERB 1Mke7 E A 0 oo oo oo conform rack clear all copies unroute all outputs J remove port Perae PT for IE sockets Conform All Ports In order to use the rack the on screen contents of the rack must match the cards physically installed in the rack connected There are two ways of achieving this Manual Conforming of Rack Select each card and manually select the appropriate card in the Card Slot Type drop down menu in the lower section of the window Once the correct card type is selected the Label at the bottom the selected card will turn green indicating the card type matches the card installed in the rack If the Card Type name is Red then there is a mismatch and the error should be corrected by selecting the correct card type Automatic Conforming of Rack Just below the rack view section of the window is the auto conform all button Pressing this button will correctly select the correct card for each slot of the connected rack Once complete all of the Card Labels beneath each slot should turn green It is also possible to auto conform on a card by card basis With a single card selected by touching any of the sockets on that card press the auto conform button next to the Card Slot type button selector in the lower section of the window This will automatically match the Card Slot type for the connected rack
2. Copying Audio and Listening to Copied Audio MADI Recorder Setup Audio from one or two D Racks can be copied to the MADI Port 3 Output by selecting the incoming Port s in the Ports list and using the Copy Audio To drop down menu For example if you want to copy D Rack 1 and or D Rack 2 Audio Inputs to a MADI equipped recorder connected on Port 3 select Rack 1 in the ports list and then select Port 3 from the Copy Audio To drop down menu Then repeat the procedure for Port 2 copying this to Port 3 as well For 56 Ch Standard MADI the 32 inputs on Rack 1 and the first 24 inputs on Rack 2 will be copied to Port 3 and can be recorded as necessary For 64 Ch Standard MADI the 32 inputs on Rack 1 and the 32 inputs on Rack 2 will be copied to Port 3 and can be recorded as necessary In addition by connecting the recorder s MADI Output to the console s MADI 3 Input the playback can be monitored in the same channels as the original source material Just press the Listen To Copied Audio button to monitor playback and press it again to return to monitoring the live sources from the rack 1 8 e DIO SD9 Getting Started Edit the Port Name here Select the port to be configured Eg Stage Rack Local Rack etc Copy Rack Audio to MADI Audio No aos Rack 1 gi D Rack We cars ow a Spied buio 1 2 3 J 5 L IE 0 1 EL L b L E L HD E LH E 1 TON JCh HAD iMt 1 Mic S 0 100 oo Auto Conforming for all ports individual racks or
3. There are also a Master button which allows you to view the Master screen The Master screen gives access to many setup and other functions which are not directly related to the console s channels 6 666 6E6 EE D E ff HT HE HT H T H H FF HT R ee ee Lidii SB iol alichalcllaiclbalallal DTS eT HNHRR HHR H HR HHR HSR He A SD9 Getting Started g eee Bro Channel Bane es eae ee eee ee ee eee The SD9 s worksurface is divided into Banks Each Bank contains twelve channels and the channels which are currently active on the control surface are defined using the fader bank buttons to the right and left of the faders screen assign A bank is a set of twelve faders and a section contains up to four banks There are two sections of the desk allowing up to 96 channels to be accessible on the worksurface To access a bank of faders press the appropriate fader bank button To switch both sections of the console to the same bank level press and hold one of the fader bank buttons The position of the banks on the worksurface is defined in the Layout gt Fader Banks panel By default the Input channels will be assigned to the first banks on the left and right sections of the console The different output channels will be assigned to the lower banks Control Groups and Master fader will also be assigned These bank assignments can be customised by the user and saved in a session at any time 1 3 4 Using the C
4. pre F Pre fader post Post fader pre M Pre mute and pre fader Insert send routed to a console output 10db pad rack out only on button for switching the send on and off and gain trim Insert send routed to a graphic EQ an on buiton for switching the send on and off Output routed to a graphic EQ no additional control Buttons become ringed in either red or green to indicate that they are on 1 8 2 Ripple Channels sss sss sss sss ees sss sees ennenen enen The ripple channels function located at the top of the route display allows consecutive channel routes to follow the routing of the current display incrementally For example Channels 1 to 8 direct outputs can be routed to Rack 1 gt Line outs 1 to 8 respec tively by routing Channel 1 s direct out to Rack 1 gt Line out 1 and allowing the ripple channels function to route Channels 2 8 automatically The number of channels to be rippled is defined either by selecting the appropriate grey numbered button or by selecting the keyboard button to the right of the numbered buttons typing the required number of channels 8 in the example above into the numeric keypad which appears and pressing OK Once you have configured the ripple channels function any routing action will also effect the appropriate number of channels above the channel being routed The ripple channels function treats stereo channels as two channels In other words if Channel 2 in the above example is stereo
5. activate the Edit function below the list and expand the required channel type list by touching its row Touching the channel name column for any channel in the list will cause a keyboard pop up to appear where a name can be typed in the usual way SD9 Getting Started 1 9 Channel Processing The EQ section comprises four user configurable parametric filters and a pair of swept High pass and Low pass filters The EQ is accessed by touching the on screen display to Assign the channel the colour changes to gold and then using the controls on the right hand side of the screen When a control is adjusted the expanded view seen below appears in the input screen but this view can be seen at any time by touching the EQ response graph on the screen Note If the expanded view does not appear when a control is adjusted open the Options panel and set the Auto Expand EQ option to Yes Touching the normal EQ response graph will show an expanded view in a separate panel The order of EQ and Dynamics in the channel signal path can be changed using the worksurface button to the right of the worksurface HPF and LPF controls eq dyn dm eq 2 Mic 3 Micd 108 4 Mic5 Jjo6 41 Mic6 I eq l l ol 8 Lae a D C 100 100 i 4 l Pear waned man PO malt HPF LPF S SE Fore el f or a yal CO leh 20 EH f OFF N i BE q L P o em D e em em et m ee S q EQ Type i F f eq SD dynamic EQ gain z A P thresh atta
6. the ripple channels function will route Channel 1 to Line out 1 Channel 2 Left and Right to Line outs 2 and 3 Channel 3 to Line out 4 etc 1 8 3 Channel Names ss sss sss sss sss sese s sees seene The black and white text box in the Setup display is used for naming the channel Channel names are displayed in the scribble strip at the bottom of the screen By default the channel is given the same name as the selected input signal Note that if no input signal is selected the scribble strip simply displays the channel number prefixed by ch for Input channels and prefixed by Aux Grp or Matrix in the case of output channels The following notes are specific to naming channels The Next button moves the entire Setup display to the next channel At the very top of the channel the channel number and input signal name are displayed for Input channels and the channel type and number are displayed for output channels These labels remain unchanged regardless of any channel naming For Input channels note that if the channel input signal is changed once a channel has been manually named the channel name will no longer follow the input signal name To reactivate the automatic channel naming function clear the name and re select the channel input Note also that the channel Output display also provides access to this channel naming facility Channels can also be named directly in the Channel List display in the Layout menu Open the display
7. 4 Hardware Configuration 1 4 1 Connections sss ss sss sc s ccc e eonan eaae aaaeeeaa Detailed information on the various systems of connection is provided in the relevant Appendix but the following diagram provides an overview of a single console rack setup All connections should be made before switching on the console and racks The console and racks may each have dual redundant power supplies and both should be switched on at all times After switch ing on the console the software will be launched automatically and the state of the worksurface and settings should be the same as when it was last Shut Down To Shut Down the console press the System gt Shut Down button and wait until you receive a message saying that it is safe to switch the power off The SD9 worksurface has 8 analogue I O and 2 AES lO L R pairs on its rear panel and additional I O is supplied in the form of a remote D Rack which has 32 analogue inputs and 8 analogue outputs as standard This rack is connected to the worksurface by a 75M STP CAT5e cable Optionally 2 D Racks can be connected to the SD9 If used with a DiGiCo Little Red Box the CAT5e ports can also be used to connect with BNC MADI equipped consoles The console also has a pair of standard BNC MADI connectors MADI IN amp OUT which can be connected to any of the range of DiGiCo stage racks DiGiRack MaDiRack MiNiRack or SD Rack with 75Ohm coaxial cables This MADI port could also be used to connect
8. individual cards s E ae penton core PU P remove port l aiana for sockets Conform All Ports Select the contents of the bottom right Select Card Type manually or Selected Socket Properties corner of the Audio IO window using Auto Conform function Edit Name and Socket options and edit Group Name Standard MADI Connections If you have a standard MADI connection not a DiGiCo Rack to your SD9 you can set the SD9 to display the MADI with generic signal names i e MADI 1 MADI 2 etc through to MADI 56 or 64 instead of the usual rack style names The naming does not affect the signal but makes routing signals easier STD MADI 56 channel MADI MADI 64 64 channel MADI Console to Console routing If two DiGiCo consoles are connected together using MADI it is possible to route audio between them The Port that is connected to the second console should be defined as a Standard MADI Connection Unrouting All Outputs All outputs to the selected port can be unrouted at once by pressing the unroute all outputs button below the cards graphic and selecting yes in the warning pop up which appears Copied audio is not unrouted by this action Note that this will cancel all routing created in the channel screens and cannot be undone Splits amp Sharing In a multi console system where Racks are connected with MADI and shared between two DiGiCo Consoles only one of the consoles can take control of the rack with respect to
9. sss sssssssss esse esse seene enen Channel Processing High and Low Pass Filters 4 Band Dynamic Parametric EQ Dynamics Thresholds amp On Off Channel Insert On Off Quick Select Touchscreen Direct Out On Off Light Controls ee H 1 H TT USB Port RE eee ee PE EE EEE LR BI R Headphone Control ip Talkback Control BL L L L So Bed K ee bas bas gt 4 Solo Buss Controls Snapshot Control Le ee Le Le Ce Le L o ee L Em L Em ee Em b ee L Zm L Zam L 0 el m LR RT 2nd Function Button m AAAAAAASAN i Master Level amp Solo 1 Option All Button a Master Screen Assign Macro Buttons eeeececels Touch Turn Controls oe HT HT HT HT HT F amp F amp 8 I Assignable Rotaries amp Screen Scroll Snapshot Previous Next LCD Functions Left Screen Assign Right Screen Assign Bank Select Buttons Bank Select Buttons 1 3 2 Screen Assignment sss sss sss cesses sse ss eee esen eenn eenn The SD9 has one central touchscreen which is used to access many of the console s functions There are 3 possible views that can be seen on this screen Left section Right section Master screen Each console worksurface section has its own Screen Assign button which when pressed will allow the channels in that section to be viewed on the screen and controlled by the Channel Processing controls such as EQ and Dynamics When the button is lit that section is assigned to the screen
10. Gain Phantom Power and Pads To overcome this it is possible to place the SD9 into one of 3 states of operation Isolate Receive Only or Full Control Sharing is configured in the bottom right hand corner of the window when the Splits amp Sharing button is selected receive only receive only full control full control These three states can be set individually in the right column on a per rack basis middle column or globally for all shared racks left column Isolate The SD9 will not communicate with the rack and therefore any adjustment of input gain or 48V switch will have no effect on the rack settings Receive Only The SD9 will receive the rack s existing settings but will not be able to control the gain etc on the racks Full Control The SD9 will send its settings to the racks and change them accordingly SD9 Getting Started 1 5 Configuring a Session The SD9 has a default setup which means that the new user need not get involved in configuring the desk at this stage However here is a brief overview of how the different displays are used in putting together a session Each of the master displays intro duced below are described fully within the SD Series Software Reference Manual The Setup gt Audio IO display is used to configure the physical I O connected to the SD9 including configuring and naming the sockets of the option cards installed in racks and the setting of pads and phantom power See previou
11. SD9 Operation Manual User Manual Getting Started To be read in conjunction with the SD Series Software Reference User Manual Version B for Software Versions 4 0 680 0 1 SD9 Operation Manual EC DECLARATION OF CONFORMITY UK Ltd This is to certify that the SD9 DIGITAL MIXING CONSOLE WORKSURFACE From serial number 90020 Manufactured by DIGICO UK LIMITED UNIT 10 SILVERGLADE BUSINESS PARK LEATHERHEAD ROAD CHESSINGTON SURREY KT9 2QL UNITED KINGDOM TEL 44 01372 845 600 FAX 44 01372 845 656 Conforms with the protection requirements of the Council Directive s 2004 108 EC and 2006 95 EC relating to Electromagnetic Compatibility and Low Voltage Directive by the application of the following standards EN55103 1 2009 Emission standard EN55103 2 2009 Immunity standard EN60065 2002 A1 2006 Low voltage directive Position Technical Director Date 12 April 2010 0 2 e DIO SD9 Operation Manual EC DECLARATION OF CONFORMITY UK Ltd This is to certify that the D RACK AUDIO I O INTERFACE From serial number 980001 Manufactured by DIGICO UK LIMITED UNIT 10 SILVERGLADE BUSINESS PARK LEATHERHEAD ROAD CHESSINGTON SURREY KT9 2QL UNITED KINGDOM TEL 44 01372 845 600 FAX 44 01372 845 656 Conforms with the protection requirements of the Council Directive s 2004 108 EC and 2006 95 EC relating to Electromagnetic Compatibility and Low Voltage Directive by the applicat
12. and dynamics on more than 8 channels Each band includes all of the parameters as those found in the single band compressor The link function remains available for the whole compressor and is not assigned to any band The bands can be switched on individually using the on buttons in the left hand side of each band or together using the all on button to the display s right The crossover frequency between bands is controlled using the purple and red pots to the left of the hi and lo bands Each crossover has a range of 20Hz to 20kHz and the crossover frequencies are displayed below each pot Each band can be auditioned by pressing the listen button below each gain pot which solo s that band to the mix not the solo buss in effect temporarily switching off the other bands Pressing multi band again returns the compressor to single band The channel strip s compressor threshold and gain controls adjustment all three bands controls maintaining any relative offsets The individual controls are mapped to the assignable rotaries below the screen Note Beyond the link function the single and multi band compressors have completely separate settings No settings are copied between them and the settings of each remain unchanged when the other is active SD9 Getting Started 1 9 3 PAS seinio aaa a The auxiliaries can be accessed by touching the Aux Quick Select button the auxiliary row on screen or using the Screen Scroll buttons U
13. ck G under dynamic on eq SD dynamic EQ fe 15 0 7 4 Bands thresh attack release G under dynamic on band on G J eq SD dynamic EQ thresh attack release G under G dynamic on band on G Dynamic EQ eq SD dynamic EQ h 136 0 150 0 x thresh attack release e under dynamic on band on safe flat presets 4 o copy ts li c EQ Presets Copy EQ Settings The type of filter used by the top and bottom bands can be changed by successive presses of the Curve button for that band The four parametric bands can be either Classic Analogue style or Precision Digital style type EQ Up to 8 Channels can have their EQ modules switched into Dynamic EQ mode by touching the red Delta symbol on any EQ band On any channel Input or Output open the EQ Module and expand the dynamic controls You can then switch on any or all or the dynamic controls for that EQ Module Only 8 Channels can have their EQ Modules placed in Dynamic mode An warning message will appear on screen if an attempt is made to use Dynamic EQ on more than 8 channels See the SD Series Software Reference manual for more information on Dynamic EQ 1 16 e DIO SD9 Getting Started 192 DYNAMICS HHH The dynamics are accessed by touching the words Comp or Gate just below the EQ graph on screen to open the dynamics panel There are two dynamics modules the first of which can function as a simple compressor a 3 way multiband compr
14. configure a new session with the following setup where the first 32 rack inputs are routed to input channels 1 32 and the Master Buss is routed to Local outputs 1 amp 2 and also to Rack 1 outputs 1 amp 2 All input channels will be routed to the Master Buss and the console headphones will be fed by the Master Buss when nothing else is soloed The default configuration is 48 Mono or Stereo input channels Fixed 6 Mono Aux busses amp 6 Stereo Aux busses Adjustable 6 Mono Group busses amp 6 Stereo Group busses Adjustable 12 Matrix Inputs and 8 Matrix Outputs Fixed 8 Control Groups Fixed 1 Stereo or LCR Master Buss 2 Mono or Stereo Solo Busses Fixed Touch number s to edit with pop up keypad or touchturn Session Structure Enter Session tile gt gt Select Session Sample rate Clear all Set number and type of Aux gt lf ae gt Adjust Group Set number and type of Group _ Clear all auto route l group order or Aux Order l clear all DEFAULT ALL clear all eer all ebuild bank build bank a L Select Bank Layout clear all E clear snapshots Clear all x Clear automation DiGiRack Det default clear macros Clear all clear all presets Option to Clear Total number parts of the session of spare when restructuring busses Option to automatically Create a default session route inputs outputs with flat parameters when using the Clear function and basic routing 1 10 DIGico SD9 Ge
15. ded by law a the remedies provided above are the Customer s sole and exclusive remedies and b Digico UK Ltd shall not be liable for any direct indirect special incidental or consequential damages including lost profit whether based on warranty contract tort or any other legal theory This agreement is made under the Laws of England Be 5 Le e Renee renee renee ee eer ee eee eee ee eee keer eae ee REGISTRATION DATE sans 09 kata S CE2 behi ges O 0 N o gt M 0 4 e TSH SD9 Operation Manual Contents ki Trees 190 e arosine EEEE E EESE AAE 1 1 1 2 Manual Overview csssss sss ss sss esse sese ss sese ennenen Kee 1 1 Ted BOTORE VOU rT aoir EEE R N 1 2 1 3 1 Worksurface Layout ssssssssssss esse sss sss esse ees enesenn ene bene 1 2 1 3 2 Screen Assignment sssssssssssss esse ss sss sese eee senenn been 1 2 1 3 3 Channel Banks xpecceadecteancesceecesnconssvecuaccennsdtavevesanesexeapncene neces 1 3 1 3 4 Using the Control Surface cccccceesseeseeseescenseneeens beee 1 3 1 3 5 The Assigned Channel ccccssseecseseeceesseecenseseoens boes 1 4 1 3 6 LING Master Fadet scsisexccccicccecnmersnccececeses ds vsdevesnsnenascecnarectenes since 1 5 Wicd OUNCE CONTOIS sirrini prenia ERANA EARRANN PENEN 1 5 1 3 8 Channel Us 1 5 1 4 Hardware Configuration ssssss sss sssss sss s sss esse sese seene ee Kee 1 6 1 4 1 KZOTINCCTONNS erdiarena niaaa a 1 6 1 4 2 Audio I O Panel wicinccsccctuscunnsvaus
16. e ports Each port relates to an available physical audio connection Local IO CAT5 or MADI Port The section immediately to the right of this contains the controls relating to the ports When a port is selected this section changes to reflect the status of the selected port and allows its configuration to be changed as required The right hand section of the Audio I O Window shows a graphical representation of the rack configuration connected to the selected port Depending on the port selected the graphic will change showing the available physical I O Each small square on the image represents a single physical audio connection or socket with these arranged in columns or rows representing I O cards in racks or the local I O on the back of the console The section below the graphical rack picture allows configuration of the cards or slots and sockets including custom naming phantom power and pad selection The local I O configuration is fixed so no hardware changes are possible You can however change the Port Name the Group Names and the Socket Names the name of each physical connector on a card SD9 Getting Started Rack Connections With a Rack selected in the left hand port selection list the window will change to look something like the image below depending on the cards installed in the connected rack The graphic shows the 6 available cards slots 4 input amp 2 output DIDI cs coo e SET MT ad concss
17. e routed directly to outputs Channels are laid out in banks of 12 on the console worksurface and can be identified by their colour Light blue for Input chan nels red for Group channels purple for Aux channels and blue green for Matrix channels By default the Input Channels will be assigned to the top banks on the left and right sections of the console The output channels Groups Auxes and Matrices will be assigned to the lower banks Control Groups will also be assigned to the lower banks These bank assignments can be customised by the user and saved ina session at any time Holding any bank or layer button down for a couple of seconds will switch both worksurface sections to the same bank level The controls on each different type of output channel are identical but an input channel has a number of additional features SD9 Getting Started Groups Auxes Matrix Input Module Touch to Expand Analogue Gain Digital Trim Phase Gain Tracking Main Alt Input Select HPF LPF Insert A Routing amp On Off 4 Band EQ Touch To Expand Dynamics Touch To Expand Insert B Routing amp On Off Aux Sends Touch to Assign Rows 769 jm 00 Frome aal a M HARD MUTE HARD WUTE HARD Cii OFF CG mie OFF cG mie OFF SAFE gt ae Channel Pan Mute amp Hard Mute MUTE HARD eet OFF GANG SAFE Channel Label Routing Module Touch to Expand Gang amp Safe Indicators Iaa or ete 1
18. er inputs insert sends and insert returns can only route to from one signal in the case of mono channels or two signals in the case of stereo channels A new route selection will therefore result in the previous selection being lost for inputs and insert sends and returns For stereo channels left and right routes are presumed to be consecutive When routing stereo signals select the left route and the next signal in the list will be automatically selected as the right route If the last signal in a signal group or port is selected as the left route the first signal in the following signal group or port will selected as the right route For input and insert return routing the INTERNAL port provides the following signal groups Misc The oscillator white and pink noise generators Graphic EQs The outputs of the SD9 s internal graphic EQ s Effects The outputs of any effects sends that have been created 1 14 e DIO SD9 Getting Started Channels The direct outputs from the other input channels Groups The outputs of the group busses Auxes The outputs of the auxiliary busses Matrix The outputs of the Matrix channels Note The outputs for the channel being routed are locked out of the signal list Note also that the console views all routes as a single list Therefore if the left signal is connected to the last signal in a port the right signal will be automatically connected to the first signal of the next port re
19. essor or a de esser according to the comp multi desser button to its left The second lower module can function as a gate a ducker or a compressor with an external sidechain according to the gate duck comp button to its left The worksurface controls beneath the screen control the various parameters Touching the Close button in the top right corner of the panel will close it Dedicated Threshold Gain controls and In Out switches can be found on the right hand side of the screen These can control the Assigned channel s dynamics whether the on screen dynamics panel is open or not DYN 1 Mode Switch mulfi band SI ynamics Ch 1 g 20 0 S thresh B on s thresh e on a GR desser i thresh G on comp i Dynamics Presets safe presets copy to attack attack release release release ratio gain l E auto gain Ji 2 00 ratio lt _ gain isten 0 0 auto gain i ratio gain listen auto gain ji alon med soft G knee i i hp ANJ 120 0 freq 7 22 0 width 5k 20k release range key listen U thresh on U 20 100 tk U DYN 2 Mode Switch Up to 8 Channels can have their Dynamics Compressor modules switched into Multi band mode On any channel Input or Output open the Dynamics Module and expand the dynamic controls using the multi band button A warning message will appear on screen if an attempt is made to use Multi b
20. gard less of port type For output and insert send routing the INTERNAL port provides access to the inputs of the SD9 s Graphic EQ s and the inputs to any effects that have been created The 0 Local I O port contains a list of the inputs or outputs found directly on the SD9 s back panel The Rack ports contain all of the inputs or outputs available within the remote I O racks as defined in the Audio I O display Once a route has been selected its name will appear below the routing button in the Setup or Outputs display Whenever a route is created metering and additional controls are made available below the routing button These controls are dependent on the type of route created and are described in detail in the SD Series Software Reference manual Local Mic input routed to an input or insert return 48V button for remote control of phantom power and a 20dB input pad D Rack Mic routed to a mono input or insert return 48V button for remote control of phantom power and a 20dB input pad D Rack Mic or Local Mic Input routed to a stereo input 48V button a 20dB input pad MS decode width balance and L R controls Mic pre amp routed to an insert return 48V button a 20dB input pad a phase reverse button and gain trim Output routed to a console output 10db pad rack out only on button for switching the send on and off gain trim and send point selector which toggles the place within the channel from which the direct output is fed
21. has an Optocore board fitted an Optocore Sync option will also be available If the console is connected to an Optocore system then the Audio Sync should normally be set to Optocore if no external clock source is required Audio Synchronisation OPTOCORE 1 13 SD9 Getting Started 1 8 Routing Basics 1 8 1 Selecting Inputs amp OUTPUTS ss sse s ccc s sese eee ennenen All channel input output insert send and insert return routing is done via routing displays accessed via the dark grey routing buttons in the channel Setup and Output displays shown below for an Input channel s input Note that multi channel signals are routed individually and then collected together as a Multi Channel as described in the SD Software Reference manual To access Channel Input Setup touch the top of an input channel display on the touchscreen To access Channel Output Setup touch the bottom of any channel type s display on the touchscreen Touch top of Select or type Input Channel Number of Inputs to Ripple Route men hoi Mann ii Hone Mono Stereo d a S rae Pr rT Pr vam Pe Y e pe ae Press Main Input sak 1 8 alt input P A INTERNAL Mic 1 8 i Mic 1 Local iO Mic 9 16 MiMe gt Rack 1 Mic 17 24 TMe 2Rack 2 Mic 25 32 Mic 4 Sete xb TMi Mic 1 Mic b 4 Mic 7 TMic E Label Channel c1 g iz l input eq dyn aux pan fadime inserts buss directs Select a Bank Cony trom copyt
22. in the pop ups are coloured grey when their function is inactive generally switching to a lighter shade of the pop up background when their function is active Pressing on a text box opens a numeric or QWERTY keypad which can be operated directly by pressing the screen or via the console s external keyboard Pop ups are closed by pressing the box in the top right hand corner of the pop up marked CLOSE or CANCEL or by pressing CAN on keypad pop ups To the right and below the touchscreen is a single encoder and switch marked Touch Turn shown below This is used to access some of the rotary and switch controls within the Master screen To assign the Touch Turn encoder to a particular on screen control touch the pot to be assigned You will notice that a coloured ring appears around the on screen pot indicating that it is assigned to the Touch Turn encoder switch 1 3 SD9 Getting Started 1 3 5 The Assigned Channel sss ssssssssssss sss essen eenn One of the channels in the Channel Strip panel is displayed in gold indicating that it is currently the Assigned Channel This means that it has been assigned to the worksurface controls and can be configured in detail as described below To Assign a channel touch anywhere in the channel on the screen Once a channel is Assigned all of the controls for that channel which are not displayed within the channel strip itself can be accessed via secondary pop ups displayed by touching
23. inside the relevant area of the channel These pop ups include controls such as input and output routing and signal processing parameters A number of the physical rotary encoders on the control surface can be assigned to different on screen pots In order to ensure that it is clear which function is assigned to which encoder the assigned on screen pot will have a coloured ring around it The twelve encoders and buttons immediately below the touchscreen shown above refer to the channels with which they are aligned Pressing one of the Quick Select buttons on the left of the screen will assign the selected function to these controls below the screen Six aux sends can be displayed in the Channel Strip panel at any one time If more than six aux sends have been created in the session the scroll button outside the bottom left hand corner of the screen can be used to scroll the display through the remaining auxiliaries The controls to the right of the Channel Strip panel allow the Assigned channel to be adjusted la chancel select 1 4 e TSH SD9 Getting Started 1 3 6 The Master Fader css sss sss ss sss sssssss esaea aeaaea By default the master fader is assigned to the master group output which is the lowest stereo group output by default In addition the master fader can be assigned to the Solo buss 2 rotary control using the on screen button in the Solos panel on the Master screen 1 3 7 Other Controls To the left
24. ion of the following standards EN55103 1 2009 Emission standard EN55 103 2 2009 Immunity standard EN60065 2002 A1 2006 Low voltage directive Position Technical Director Date 12 April 2010 0 3 SD9 Operation Manual Copyright 2014 Digico UK Ltd All rights reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form by any means without the written permission of Digico UK Ltd Information in this manual is subject to change without notice and does not represent a commitment on the part of the vendor Digico UK Ltd shall not be liable for any loss or damage whatsoever arising from the use of information or any error contained in this manual All repair and service of the SD9 product should be undertaken by Digico UK Ltd or its authorised agents Digico UK Ltd cannot accept any liability whatsoever for any loss or damage caused by service maintenance or repair by unauthorised personnel Software License Notice Your license agreement with Digico UK Ltd which is included with the SD9 product specifies the permitted and prohibited uses of the product Any unauthorised duplication or use of Digico UK Ltd software in whole or in part in print or in any other storage and retrieval system is prohibited Licenses and Trademarks The SD9 logo and SD9 name are trademarks and Digico UK Ltd and the Digico UK Ltd logo are registered t
25. ividual channel faders 1 20 TSH SD9 Getting Started 1 12 Solo Setup The SD9 Solo panel is accessed from a button at the top of the Master Screen Some of the controls on this panel are duplicated on the left worksurface section There are two solo busses and each channel on the consoles can be independently assigned to use Solo1 Solo2 or Solo 1 2 Therefore if the console was being used for Stage monitors the first solo buss could feed In Ear monitors and the second solo buss could feed a wedge single clear t ee UG sip 5 E ofl afl solo mode Saas ree multi single solo mode K d Clear U Solo Level gt Mono Stereo Surround switch gt Or Ia Prono dmM Solo Delay No solo source select gt no solo no solo Waster L none i insert insert Insert routing gt ae f pme R Direct Out routing gt direct outs c direct outs J leel level Headphones On Off b headphones headphones Floating Meter Direct Out Level Display On solo level 2 The following functions are available independently for each solo buss Mono Stereo Surround Switch No Solo source routing Insert Point with both internal and external routing capability Direct Out routing eg for feeding a wedge Assignment of worksurface rotary to either Solo 2 Master or Main Buss Master afl or pfl mode single or multi solo mode De
26. lay Level Trim Auto solo mode Floating Meter No Solo Source for solo buss when no channel is in solo mode No Solo source does not show on Solo meters Auto Solo If a channel is set to Auto Solo it will automatically solo when another channel is soloed The Auto Solo function of each solo buss can be enabled and disabled as required The solo buss must be in multi mode for the auto solo function to operate OS 1 21
27. nput 1 Mic 2 to input channel 2 until you either run out of inputs or channels Auto routes are as follows Input Channels auto route with physical inputs Aux Group and Matrix Channels auto route to physical outputs Matrix Inputs auto route with group outputs NOTE Auto Routing can only be used in conjunction with the Clear All button 1 5 2 Assigning Faders to the Worksur face 0sseessseees If after a Session Restructure where the Rebuild Banks button was not pressed you find that newly created channels do not appear on the worksurface open the Layout gt Channel List panel on the Master screen and you will see a full list of all input and output channels that are present in the session To assign channels to the worksurface select a bank and press the LCD Function button Then press the Channel Select button below the display labelled Copy Bank From to enter that mode Now press the first channel that you wish to assign on the Layout Channel List on the Master screen Consecutive channels will be assigned to the worksurface for each channel in the selected bank Now press the LCD Function button again and return to the standard mode by pressing the LCD button labelled Solo Custom Fader Assignments Press LCD Function button then Assign Faders Whole Bank Assignments Press LCD Function button then Copy Bnk From Press LCD button s for Assignment Open Layout Channel List Click down arr
28. o ee een Or Se SR 9 auto SON ir tor hr ler L Aar PA ter MUTE HARD MUTE HARD 1 MUTE HARD MUTE Ce OFF Mam cue OFF Gm Cue OFF Me cule OFF gam cu Within each display there are three columns containing three levels of routing selection The left hand column contains the available ports within which the desired input or output might be located The middle column signal groups then shows the available groups of inputs or outputs within that port The right hand column signals then displays the individual inputs or outputs available within that signal group The boxes in each column are lit blue to indicate that they are currently selected If there is already a routing assigned within the display the port and signal group columns containing the current assignment will be half lit Each output can only have one channel routed to it The outputs that are currently in use by another channel display in blue text If you attempt to route a different channel to an output which is already in use a confirmation box appears indicating which channel is already using it and warning that continuing with the action will cause the old channel to be derouted from this output Press Yes to proceed No to cancel Note that when routing direct outs from Input channels or outputs from output channels any number of available signals can be selected A new route selection will therefore be added to previous selections in these cases Howev
29. of the screen are more channel controls When pressed the 2nd function button allows access to different param eters 1 Stereo Aux Pan and Pre Post switching 2 Hard Mute of a channel 3 Fine adjustment of Delay settings on output channels The Option All button has 2 main functions 1 When pressed and released any channel that is a member of a gang will be temporarily isolated from that gang 2 When pressed and held any parameter that is adjusted on a single channel will also be adjusted in the same way on all of the channels in that bank 1 3 8 Channel Types sss sss sss sss sees seene ennenen The signal flow of the SD9 is best understood in terms of the four channel types contained within it shown below Each channel type offers full signal processing capabilities As a summary the four channel types are as follows Input channels bring signals into the console to be mixed and sent to aux and group busses Aux channels send a variety of mixes of the Input channels to the Aux outputs mainly for use as monitor mixes and FX sends Group channels mix groups of input channels together to feed the buss outputs or the output matrix Matrix channels send the outputs of the matrix to the console s main outputs Optionally The Group channels Aux channels and Matrix channels are all referred to as output channels While the Aux and Matrix channels are the channel types most commonly routed to outputs all four channel types can b
30. ontrol Surface cesses ssssssssssssss esse ennenen neee There are two main ways in which all of the functions of the SD9 are accessed 1 The touchscreen display which can be controlled directly using a finger or by using the keyboard and mouse 2 The physical encoders switches and faders Note that when touching the screen directly you may find it easier to use a finer point than your finger However in order to prevent damage to the screen it is important that you only use devices specifically designed for touching screens such as a pda stylus and that you never press down hard on the screen A number of functions can be accessed in different ways allowing users to operate the console using whichever interface they prefer This manual will describe accessing on screen functions by touching the screen directly and not by using the mouse All of the physical controls found in the upper section are described in full within the relevant section of the manual and many require no further introduction The Master screen has a row of grey buttons which are used to access a range of configuration displays Pressing these buttons opens either a further drop down sub menu or a pop up display If a drop down menu is opened pressing on one of its entries will open a pop up display The buttons lighten to indicate that their sub menu or pop up display is open A number of the buttons within each pop up display generate further pop ups The buttons with
31. ow to expand list Channel Ls Touch first channel to assign SD9 Getting Started 1 6 Saving and Loading Sessions 1 6 1 Save As New File cesses sese seess esse eenn nenen ennenen When you change the configuration of the a session you should save it to the console s flash drive under a new filename If the Save Session panel has not appeared automatically after a session restructure then touch the Files button on the Master screen and then press Save As New File Select the destination drive Internal or Removable and file path and then enter a new file name and description for the file then press the Save button Note If you touch a session name on the existing list this name will automatically be selected as the new file name and touching Save will overwrite the old file Enter a Filename Enter a Description Select Internal or Removable USB Internal files saved in D Projects To create a new folder in D Projects 1 6 2 Save Session sss sss sss eee eenn ennenen eenn This button which is found above the Save As New File button will save the existing session in the same location and under the same file name as it was previously saved or loaded from It therefore serves as a Quick Save option to update an existing session Remember that this function will overwrite your last saved version If you wish to save the session under a new name use the Files menu button and select Save As New File See above Load Ses
32. provided for by law and then only after consultation with Digico UK Ltd The Customer agrees not to use or licence the Product for use with equipment other than the Target Platform The Customer agrees not to modify the Product without the prior written consent of Digico UK Ltd This Agreement applies to any enhancement or upgrades that may become available for the Product This Agreement does not transfer any right title or interest in the Product to Customer except as specifically set forth herein Digico UK Ltd reserves the right to terminate this Agreement upon breach in which event Customer shall thereafter only be authorised to use the Product to the extent that its contractual commitments to third parties require and then only where such commitments relate to use of the Product as authorised in the foregoing provisions of the Agreement LIMITED WARRANTY Digico UK Ltd warrants for a period of 1 year from the date of purchase of the Product the Product will reason ably execute its programming instructions when properly installed on the Target Platform Inthe event that this Product fails to execute its programming instructions during the warranty period the Customer s remedy shall be to return the Product to Digico UK Ltd for replace ment or repair at Digico UK Ltd option Digico UK Ltd makes no other express warranty whether written or oral with respect of this Product LIMITATION OF LIABILITY Except as otherwise expressly provi
33. rademarks of Digico UK Ltd Microsoft is a registered trademark and Windows is a trademark of Microsoft Corp Digico UK Ltd Unit 10 Silverglade Business Park Leatherhead Road Chessington Surrey KT9 2QL England Telephone 44 0 1372 845600 Fax 44 0 1372 845656 Email sales digiconsoles com WWW http www digiconsoles com Manual Issue and Date Issue B 10th April 2014 For Version 4 0 680 Software Licence Agreement Product SD9 software product produced by Digico UK Ltd intended for use on Target Platform identified below Target Platform Digico SD9 Digital Console system In return for the payment of the one time fee the Customer identified at the end of this Agreement receives from Digico UK Ltd a licence to use the Product subject to the following terms and conditions 1 The Product may be used without time limit by the Customer on the Target Platform 2 The Customer must register the Product with Digico UK Ltd Registering the Product is deemed an acceptance of the terms and conditions in this agreement 3 The Product and its licence are not transferable and the Customer is not permitted to onward license to any third party The Cus tomer indemnifies Digico UK Ltd against any and all claims and actions arising from third party use of copies of the Product made by the Customer 4 The Customer agrees not to attempt to decompile the object code of the Product otherwise than in circumstances specifically
34. rd SD9 input routing page with options to select any console or rack signal as a Matrix input Matrix inputs Matrix Input Routing gt mtx In 3 HL ms In 4 ms In 5 mtx In 6 mtx In 8 mtx In 9 l mms In 10 mas In 14 mtx In 12 Matrix crosspoint level controls gt J Tor orr orr orr a orr orr forr orr 2 orr orr orr orr Matrix Snapshot Safe Control gt pa an single m Matrix Preset control Touch Turn assignments The example above has the Master Stereo Buss routed to the inputs of Matrix 1 and Matrix 2 Labelled as PA LEFT amp PA RIGHT By adjusting the crosspoint levels you can change how much of each side of the Master buss is fed to these Matrix Channels There are three modes of level adjustment multi single amp all Multi Touch one or more level knob on screen then adjust using the Touchturn control Single Touch any level knob and adjust Touching another knob will deselect the first All All knobs are adjusted at the same time When adjusting more than one crosspoint their relative levels are maintained 1 19 SD9 Getting Started 1 11 Control Groups Any number of input channels and output channels can be connected to one or more of the 8 Control Groups They can then all be operated from a single worksurface channel Changes to the Control Gro
35. s up to 24 mono or stereo busses 12 Matrix inputs and 8 Matrix outputs 16 onboard graphic EQs and 8 onboard stereo effects The left and right sections each have 12 assignable faders and 12 sets of assignable encoders and switches Either of these worksurface sections can be assigned to the centre touchscreen Multiple console setups can provide Front of House and Monitoring with a shared stage rack and gain tracking Remote control of a console from a laptop computer 1 2 Manual Overview This manual provides an overview of the desk and describes some of the basic operating principles which the user will need to understand in order to run the desk For full details on all SD software functionality please refer to the SD Series Software Reference Manual available for download at www digico biz The following typographical conventions are used in this manual Bold type is used to indicate that the text is an exact copy of the labelling either on a screen or on the worksurface An arrow bracket gt is used to indicate a sequence of button pressing For example Layout gt Fader Banks indicates that the Fader Banks button is accessed by first pressing the Layout button 1 1 SD9 Getting Started 1 3 Before You Start There are certain general operating principles and terms that should be understood before continuing to use this manual Please read this chapter carefully before proceeding 1 3 1 VV OFK SUPT ACE Layout
36. s section The File gt Session Structure display is used for configuring how the console s the DSP channels is to be divided between channel types and where the format of the channels is defined The Session Structure display can be used to automatically assign the channels to the worksurface However channels can also be manually added to the worksurface using the Layout gt Channel List display 1 5 1 Session STG When starting a new session it is important to decide how many of each type of buss is required While changes to session structure can be made once a session has been started it is best to try and set these parameters before configuring the session The structure will set the number and type of aux and group channels and allow you to choose which parts of the new session will be cleared and reset There is also an option to automatically route the inputs and outputs from channel types that you have opted to clear To adjust any of the channel allocations touch on the associated channel count box and either enter a number using the pop up number keypad or adjust using the assigned touchturn controller The maximum total amount of Aux and Group channels available is 16 mono or stereo As you increase the number that you require you will see the resources available decreasing accordingly in the number display at the bottom of the panel Note Pressing the Default All button followed by the Restucture button will automatically
37. sing either of these methods the highlighted auxiliaries on the input screen will change The row of rotary controls and switches beneath the screen are used as auxiliary sends pans with 2nd Function ON On Off and pre post switches with 2nd Function ON Touching the selected Aux row on the selected channel will open the Expanded Auxes panela nd the row of rotary controls beneathe the screen will be assigned to each of the Aux Sends on the selected channel Selecting another channel with the Expanded Auxes panel open will display the Expanded Auxes panel for that channel aux sends safe presets copy to Aux 1 Aux 2 Aux 3 Aux 4 Aux 5 Aux 6 Aux 7 Aux 8 Orr Me OFF GR OFF a OO FF Se OFF Gee OFF Gee OFF GM OFF U U U U OFF OFF OFF OFF OFF l OFF l OFF l OFF U Touch to select Expanded Auxes EB larr l larr Aux Quick Select OFF L Q J OFF GFF GFF rE A MUTE HARD MUTE HARD MUTE HARD cG mit co mit co mit come I I ol GANG SAFE GANG SAFE GANG SAFE GANG SAFE E Assignable Controls L Press Aux Quick Select screen serol To adjust Aux controls x 6 R 1 18 DIGIC O SD9 Getting Started 1 10 The Matrix To open the Matrix Inputs panel touch the Matrix button on the Master Screen Menu The window that opens allows you to route inputs to the Matrix Output Channels and set the Matrix crosspoint levels To route an input touch the top of the appropriate Matrix column This opens a standa
38. sion To load a previously saved session Touch the Files button on the Master screen and then press Load Session Select the source drive Internal or Removable and the required file from the list then press the Load button Select a File File Details Select Internal or Removable USB OTE 1 565 150608 18 273 Dairine of Maread 1 7 BB 68 02 f 03 681 S idi 19 22 Oeseripien of Marat 2 ft 66 B LE in D Projects Press Load 1 12 DIGICO SD9 Getting Started 1 7 Audio Sync The SD9 operates a Sample Rates of either 48000Hz 48kHz or 96000Hz 96KHZ By default it is set to clock internally as a Master and the Sample rate is determined by your selection in the Session Structure panel Within a normal setup the SD9 will usually remain as clock master However there are times when the SD9 needs to be clocked externally The Audio Sync panel allows you to control external synchronisation To access the Audio Sync Panel touch the Setup Menu button followed by Audio Sync The following panel will open Audio synchronisation MASTER The SD9 will clock from the following sources Word Clock CAT5 1 CAT5 2 and MADI 3 Note When a valid clock is detected on an external sync input the corresponding Green OK box will light even if that input is not selected as the clock source for the SD9 The second picture above shows an example of External Clocking Word Clock 48kHz Note If the console
39. to a MADI equipped recorder From Mid 2013 new SD9 consoles can also be fitted with optional Optocore connectors providing the possibility of including an SD9 in a DiGiCo Optocore loop The connection for the D Rack is a single cable from the D Rack port on the back of the console to the DiGiCo Audio Interface port on the D Rack In normal operation the MADI connections on Port 3 should be as follows Rack MAIN MADI IN connected to the console MADI OUT Rack MAIN MADI OUT connected to the console MADI IN 1 6 e TSH SD9 Getting Started DiGiRack MaDiRack MiNiRack OR MADI Recorder 1 4 2 Audio VO Panel cc css sss sss sss aeaaaee aeaaeae The Audio lO panel is used to configure the physical I O connected to the SD9 including configuring and naming the sockets of the cards installed in racks and the setting of Pads and phantom power Local I O The SD9 provides local audio I O in the rear of the console These operate independently of connected racks To access the SD9 Audio I O Setup touch Setup gt Audio I O on the Master Screen The Audio I O panel that opens is divided up into the following sections aT debe Selected Port s Port Selection Properties and Status Graphic Representation of Selected Rack ET Configuration of P nce E s Cards amp Sockets Global Port Conform ap Forts chet Optie or Splits amp Sharing Management as defined by buttons to the left The left side of the window shows th
40. tting Started Clear All Buttons When changing routing you have the option of clearing any non default routing or processing EQ dynamics etc from the channels in the session This is especially useful when restructuring an existing session to make a new session The clear snapshots clear automation and clear macro s perform similar operations Rebuild Banks When changing the session structure there are two possible scenarios If you restructure the session without rebuilding banks any additional channels you have allocated are not placed on the worksurface and need to be manually assigned to faders If however you restructure a session with Rebuild Banks enabled the worksurface will be built with all channels available on the worksurface Banks can be laid out horizontally or vertically according to the button selected Aux Sends and Direct Sends By toggling the state of the Aux Sends and Direct Sends Buttons in the Input Channels section it is possible to change the default operation of the Aux Sends and Direct Sends These functions toggle between Post Fader Pre Fader and Pre Mute These buttons can only be used in conjunction with the clear all function Auto Route The Auto route functions automatically routes consecutive inputs for input channels and consecutive outputs for busses For example auto routing 32 inputs will route the first physical input eg 1 Mic 1 to input channel 1 the second physical i
41. up fader mute or solo or controls will affect all channels connected to the group There are 2 methods to set up Control Groups 1 Press the LCD Function button on a CG fader bank Press the JOIN CG button Press the channel select button for the CG that you want to use Press the channel select buttons for each of the channels that you want to make members of the CG Release the JOIN CG button and return to standard Solo mode by pressing the channel select button beneath the LCD display labelled SOLO l join leave Press LCD Function Button then JOIN CG Press Channel LCD buttons to Assign Members 2 Press the on screen JOIN LEAVE button for the required CG channel Press the channel select buttons for each of the channels that you want to make members of the CG Release the JOIN LEAVE button List Of Members Press Join Leave button on the required CG screen Press Channel LCD buttons to Assign Members A list of all the connected channels and their names is displayed above each Control Group display You can also clear all the channels from a Control Group by pressing Clear When a channel is a member of a Control Group its own controls can still be adjusted independently of the other Group members Adjustments to fader levels are transmitted to the Group members as dB changes so that a level increase of 2dB on the Control Group fader will increase all the member levels by 2dB irrespective of the relative levels of the ind
42. vnnsecnwsduncdaansdoosnceasendeadbqastnrasunass 1 7 1 5 Configuring a Session cssss cesses ssc ss sees esen eenn Kee 1 10 1 5 1 SESSION Structure cesses sese ese eee eenn ennenen ee een 1 10 1 5 2 Assigning Faders to the Worksurface ccccssee ess 1 11 1 6 Saving and Loading Sessions css ssss sss sss esse esse sese ene Kee 1 12 17 AUdIO SYNC E 1 13 1 8 Routing Basics ssssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn Keene 1 14 1 8 1 Selecting Inputs Outputs ss sssss esse see sss esse sese sees eee Keen 1 14 1 8 2 Ripple Channels sssssssss sss ssssss sese eess enesenn ennes Keen 1 15 1 8 3 Channel Names sss esec ssss sss sss s sss es sees enen cence 1 15 1 9 Channel Processing s sss sss esec sss sss esse sese eenn ennenen Keen 1 16 Ee a 0 E nirs dace E A E E E A EE 1 16 Me DY NaM S S AEAEE EEEE S 1 17 1 9 3 Auxiliaries sss sss sss sssssssesees enean ennenen enean enne Kee 1 18 a LY The Mat d 1 19 Tel GOTO Ree 1 20 1 12 Solo Setup ccsssss esec sss saw aeea ees ennenen neee enen neee gene 1 21 0 5 SD9 Getting Started 1 1 Introduction The Digico SD9 consists of a worksurface with an onboard audio engine and a range of onboard inputs and outputs This can be connected to multiple Input Output Rack Units by CAT5 cable or MADI links which carry all the audio input and output signals The console worksurface consists of 2 sections that can control 48 mono or stereo input channels 8 VCA

Download Pdf Manuals

image

Related Search

Related Contents

SCANORA® 3D - thetechgods.net  pdf manual  GX -3i2 and GX -4i2 Rangefinders  Valcom Mounting Bracket  Polar AW200  

Copyright © All rights reserved.
Failed to retrieve file