1. JLOGY ACT DASR101 Disk Array Series products Quick Installation Guide 1 0 ACE POWER COMPUTER TECHNOLOGY CORP 17F 3 No 116 Zhengxin St Zuoying Dist Kaohsiung City 813 Taiwan R O C TEL 07 5575193 FAX 07 5585192 skype avangel5193 E mail honetek honetek com http www honetek com Copyright and Trademark Once the production information in this user manual 15 changed gt it won t be particularly noticed gt ACT 1s ACE POWER COMPUTER registered trademark and Microsoft and Windows are US Microsoft Corporation s registered trademarks gt The trademark are proprietors intellectual property gt This manual 1s protected under International Copyright Law to remain all rights gt No electrical or mechanical copy distribution or writing any words without our paper agreement gt Disk storage controller of ACE POWER COMPUTER is used to copy personal information or system It s illegal to against the Copyright Law and storage devices from ACE POWER COMPUTER date only support legal backup purpose gt ACE POWER COMPUTER is not responsible for under illegal behavior gt Table of contents T AAA ao Ya Aa aa Po 4 BEL WA AA AAA 4 11 2 Spo c I o A T E T 4 1 3 AC TEDASRIOLSenes IAA 5 2 Hardware Installation 6 24 kientuly RAID SUS WI ma a REAA 6 22 Installation AAA EA 7 2
2. 11 HDD T s ili AAA 7 3 Configure RAID Subsystems 8 Sak on sgralondHet od WA 8 SLI Usm CCD CN uuu aasma COGI ESO SEE TNT 8 4 Connect ACT DASR101 11 TL Connect AC LU MIO PIKI 11 42 Connect ACT DASRTIOTEB BBU 10 Poa 11 5 LCM configuration menu 12 Ss AI 12 SEND nul rr 12 d d 4 d NR LE S B A A QE RR RE PR E S 4 2 NN B LE B B B B B 4 BN M RR P P d d Lit ithe M NN P REN E NB E NN NM NN RE PP LE B 8 NN h RA B B B B B BUM NN NR P POP d d ITHTTHT LP PX LM e cur Sd s i c i Wf air c cic car cuc D air cc c qo A C Dl Be IA i i ul Dui 1 1 1 Introduction ACT DASR101 is specifically for personal video audio editing storage and DVR Raid storage applications It allows easy scalability from JBOD to RAID It can be configured to RAID levels 0 1 and Smart Copy The RAID function allows one HDD failure without impact on the existing data and failed drive Data can be reconstructed from the remaining data and parity drives RAID configuration and monitoring can be done through the LCM front control panel For ACT DASR101 that is a internal platform The RAID subsystem controller 15 designed to fit in a two 5 25 half heigh drive bay for eas
3. 2 2 1 HDD Installation step 1 Press slide lock Right step 3 Press tray handle Sliding tray with hard drive into enclosure step 4 Mounting RAID Subsystem in system step 5 Connecting RAID Subsystem power step 6 Connecting RAID Subsystem to Host channel SATA eSATA USB2 0 You can configure RAID Subsystem either through the LCD configuration utility 3 1 Configuration methods 3 1 1 Using LCD Module LCM The LCM is the primary user interface for the RAID subsystem All configuration and management of the controller and it s properly connected disk arrays can be performed from this interface The quick RAID setup flow chat is showed as following Power Utran 1 16 MENU 1 RAID 1 After Initial push ENTER key push ENTER key 1 DISK INFO push ESC key T HDD Model Cap Bot OK push ESC key Serial Number Rebuilding 1 Up key mwa Rebuild Down ke Rebuilding 2 RAID MODE X TOY ZZ RAID MODE B HDD Model Cap Serial Number I Up key MAIN Page OWT EVENT LOG Format 3 ENVORINMET XX CYYYYRPM 1 T B REASON YYYY MM DD HH MM I Up key Down key push ENTER key TOP HDD 4 BUZZER ON OFF BOT HDD ON REASON 1 NO HDD Up key 2 FAIL 3 BAD SECTOR 4 INSERT 5 REBUILD OK push ESC key 4 BUZZER ON OFF ON 4 ENTER key ENTER ke 4 BUZZER ON OFF OFF 5 REBUILD PRIO HIGH Down ke S REBUILD PRIO HIGH push ENTER key push ESC ke
4. f the pc system and the other end into the eSATA port of ACT DASRIOIEE EEU 2 Connect the power cord Once installing successfully you can find 101 as a non initial Disk in Disk manager under my computer and then to Format this Disk 11 ja m a m s a a Q mm m M E P n T 1 a m H ipa EE W I SW mw w m m MS mE 5 1 LCM menu tree 2 RAID MODE RAID 1 MODE 3 ENVORINMET XX CYYYYRPM 4 BUZZER ON OFF ON 5 PRIO HIGH 6 EVENT LOG 7 TIME HH MM Year Month Day 8 N Backup Time Y M D HH MM 5 2 LCM menu rr Us see eerer sade te ee ee eee bea P Pm m ma ee ab cx SEP Sum See 5 Au ones a ane m Nm ECS umi s s configuration menu s m mi m 5 55x m m m E RE SS uw See eR BOB EO Wu E ms 5 5 25x ww E dm m E s 5 REBUILD PRIO 6 EVENT LOG 7 TIME HH MM 1 DISK INFO 2 RAID MODE LCM Menu Title 3 ENVORINMET 4 BUZZER 8 N Backup Time
5. t Copy Supports more than 2TB Bytes RAID drive HDD hot swap Rebuilding speed 250GB hour Supports Hot Spare on RAID Array roaming Supports partial slumber power saving mode Supports on line command based bad sector recovery Supports staggered spin up Support Device Status LEDs Error Activity Link 7NWFFUFWWHHSSSSRERHSSZSSS5SES HJuJ3UNss55NBERUAS 373223598yZHJZJ V 3735 S95 m s ss OLELE u s Ll LL A LL A 1 LA hys aia iens nana phy 2 1 Identify RAID Subsystem part stepl Front View 1 TRAY 1 2 TRAY 2 3 LCD MODULE 4 TOP KEY LOCK 5 BOT KEY LOCK 6 TOP HDD Link amp Access LED 7 BOT HDD Link amp Access LED 8 Alarm 1 IDE Host Channel Adapter Port 2 SATA Host Channel Adapter Port 3 4pin power connector 4 Fan 5 RS 232 PORT 6 SATA TRANSFER SPEED JUMPER OPEN 3 0G CLOSE 1 5G step 3 LCD Module ESC 4 Up A 2 ENT 3 Down 5 There are 4 keypad buttons and an LCD on the panel of ACT DASRIOI 1 It shows all functions and messages 2 It is used to scroll up through functions or menus 3 It is used to execute a selected function 4 It is used to cancel a selected function 5 It is used to scroll Down through functions or menus
6. y L Up key Down key push ENTER key ENTER key 6 EVENT LOG ee 5 REBUILD PRIO Up key MIDDLE Down key ENTER key 7 TIME HH MM Year Month Day S REBUILD PRIO LOW I EVENT Up key Down ke 8 N Backup Time Up ke Y M D HH MM Down key Then in any menu not pressed I L 10 any key within 10 seconds Down ke the return to the main screen 1 DISK INFO Up key Down key 1 EVENT MENU 2 Push ENTER key for 3 second enter to set RAID mode push ENTER key for 3 RAID CINFIG second PLEASE SHOT DOWN I RAID 1 Down key Up ke push ENTER key for 3 RAID CINFIG second 2 RAID 0 Down key SPEO ENTER key RAID CINFIG 2 RAID 0 push ESC key YEAR MONTH DAY YYYY MM DD SET SET Down key ESC key HOUR MINUTE HH MM SET Up key push ENTER key SMART COPY push ESC key COPY CYLCE XDAY HH MM SET Down key Up ke l WHEN FALG AT SET n push ENTER key for3 second RAID CINFIG I RAID 1 PLEASE SHOT DOWN AND REBOOT 4 1 Connect ACT DASRIOI to pc 1 pc case insert ACT DASR101 and connect two 4 PIN power cords to make ACT DASRIOI work well 2 Connect a SATA cable to the SATA port of the system board 3 Connect the other and of the SATA cable to ACT DASRIOI 4 Fasten with 12 screws and close the pc case 4 2 Connect ACT DASRIOIEE EEU to pc Insert one end of the ESATA cable into the eSATA port o
7. y built in the pc server For ACT DASRIOIE series is RAID tower platform It features two 3 5inch SATAII disk drives with RAID 0 1 Smart Copy and connects to the host system through and eSATA USB IEEEI394 interface For ACT DASRIOI series RAID subsystem that 15 also a standard part of all major operating systems such as xp 2000 2003 server Mac Linux etc the host system does not require additional or proprietary software to work with the controller 1 1 2 Specification Host Interface 3 0Gbps SATA port one ATA 133 IDE port s lt Disk interface Two 3 0Gbps SATA ports for 2 5 3 5 HDD lt RAID Features RAID levels 0 1 Smart Copy HDD hot swap Automatic online background data rebuilding Automatic disk failure detect Array roaming Rebuilding speed rata 250GB per hour Max lt Management Driverless need no driver on host side LED indicators for Disk status display LCD control panel for operation status display RAID level configuration and selection by LCD panel NVRAM for event log and system configuration setting X Dimension 210x 146 x 86mm ACT DASR101 Series products Type Host Interface ACT DASR101 SATAII Internal ACT DASR101EE ACT DASR101EU ACT DASRIOIEEU eSATA USB2 0 LCD Standard part Raid Features Two 3 0Gbps SATA ports for 2 5 3 5 HDD RAID levels 0 1 Smar