Home
        User Manual - Future Electronics
         Contents
1.    Powering Connectivity    REV  1 0 0  1 0 INTRODUCTION    XR17V358 354 EVALUATION BOARD USER   S MANUAL    This user   s manual is for the XR17V358 354 evaluation board  The XR17V358 and XR17V354 are available in  the same package and are pin compatible  therefore they share the same evaluation board  This user   s  manual gives an overview of the evaluation board and the jumper settings for testing various modes using the    evaluation board   2 0 OVERVIEW    This evaluation board has a x1 PCle connector and will work in any x1  x4 or x16 PCle slot  Up to 16 UART  ports can be tested on this evaluation board when 2 XR17V358 are installed  The PCle interface of the master  device is connected directly to the PCle connector  The master device communicates with the slave device via  Exar   s proprietary expansion interface  The PCle interface on the slave device is not used     FIGURE 1  PCIE AND EXPANSION INTERFACE       XR17V358 354  Master    Device             Expansion  Interface XR17V358 354  Slave  Device       2 1 Evaluation Board Components for Master Device    The table below shows all of the components that are on the evaluation board for the master device     TABLE 1  COMPONENTS OF THE XR17V358 EVALUATION BOARD    XR17V3581B 1 76 F  XR17V3541B176 F    FUNCTION    XR17V358 or XR17V354 PCle UART master device        SP336EEY L    Exar RS 232 RS 485 Transceiver for master device UART channel 0        SP336EEY L  SP336EEY L    Exar RS 232 RS 485 Transceiver for master
2.  device UART channel 1   Exar RS 232 RS 485 Transceiver for master device UART channel 2        SP336EEY L    Exar RS 232 RS 485 Transceiver for master device UART channel 3        SP336EEY L    Exar RS 232 RS 485 Transceiver for master device UART channel 4        SP336EEY L    Exar RS 232 RS 485 Transceiver for master device UART channel 5        SP336EEY L    Exar RS 232 RS 485 Transceiver for master device UART channel 6        SP336EEY L    Exar RS 232 RS 485 Transceiver for master device UART channel 7        SP336EEY L             Exar RS 232 RS 485 Transceiver for master device UART RI  signals  channels 0 3        Powering Connectivity    XR17V358 354 EVALUATION BOARD USER   S MANUAL REV  1 0 0    TABLE 1  COMPONENTS OF THE XR17V358 EVALUATION BOARD    SP336EEY L    FUNCTION    Exar RS 232 RS 485 Transceiver for master device UART RI  signals  channels 4 7        SP3497EEN L    Exar RS 485 Transceiver for master device UART channel 4  Not  installed        SP3497EEN L    Exar RS 485 Transceiver for master device UART channel 5  Not  installed        SP336EEY L    Exar RS 232 RS 485 Transceiver for master device UART channel 3  and 4 for RS 485 full duplex testing  Not installed        HSDL2300    IR Transceiver  Not installed        SP6654EU L    Exar 800mA buck regulator  Not installed        93C46  PDIP     External EEPROM for storing Vendor ID and Device ID  Not pro   grammed        93C46  TSSOP              External EEPROM for storing Vendor ID and Device ID  Not
3.  installed     2 2 Evaluation Board Components for Slave Device    The table below shows all of the components that are on the evaluation board for the slave device  If the slave  device is not installed  then these components will also not be installed     TABLE 2  COMPONENTS OF THE XR17V358 EVALUATION BOARD    XR17V3581B176 F  XR17V3541B176 F    FUNCTION    XR17V358 or XR17V354 PCle UART slave device        SP3245EEA L    Exar RS 232 Transceiver for slave device UART channel 0        SP3245EEA L    Exar RS 232 Transceiver for slave device UART channel 1        SP3245EEA L    Exar RS 232 Transceiver for slave device UART channel 2        SP3245EEA L    Exar RS 232 Transceiver for slave device UART channel 3        SP3245EEA L    Exar RS 232 Transceiver for slave device UART channel 4        SP3245EEA L    Exar RS 232 Transceiver for slave device UART channel 5        SP3245EEA L    Exar RS 232 Transceiver for slave device UART channel 6        SP3245EEA L    Exar RS 232 Transceiver for slave device UART channel 7        SP3497EEN L    Exar RS 485 Transceiver for slave device UART channel 4        SP3497EEN L    Exar RS 485 Transceiver for slave device UART channel 5        SP336EEY L             Exar RS 232 RS 485 Transceiver for slave device UART channel 3  and 4 for RS 485 full duplex testing  Not installed        Powering Connectivity    REV  1 0 0 _ XR17V358 354 EVALUATION BOARD USER   S MANUAL  2 3 Jumper Settings for Power Sources for Master Device  The following table
4.  shows the jumper settings for selecting enabling the power source for the master device   TABLE 3  JUMPER SETTINGS FOR POWER SOURCES FoR MASTER DEVICE  JUMPER FUNCTIONS COMMENTS    3 3V supply voltage for the 3 3V Core Jumper between 1 amp 2       Enables Disables Internal Buck Regulator Jumper is not in   Internal buck regulator is enabled       3 3V supply voltage for the output stage of buck regulator   Jumper between 1 amp 2       3 3V supply voltage for analog blocks of buck regulator   Jumper between 1 amp 2       1 2V regulated voltage from internal buck Jumper between 1 amp 2       1 2V supply voltage for 1 2V PHY Jumper between 2 amp 3 to use internal buck regulator                1 2V supply voltage for 1 2V Core Jumper between 2 amp 3 to use internal buck regulator    2 4 Jumper Settings for Power Sources for Slave Device    The following table shows the jumper settings for selecting enabling the power source for the slave device   TABLE 4  JUMPER SETTINGS FOR POWER SOURCES FOR SLAVE DEVICE  JUMPER FUNCTIONS COMMENTS    3 3V supply voltage for the 3 3V Core Jumper between 1 amp 2       Enables Disables Internal Buck Regulator Jumper is not in   Internal buck regulator is enabled       3 3V supply voltage for the output stage of buck regulator   Jumper between 1 amp 2       3 3V supply voltage for analog blocks of buck regulator   Jumper between 1 amp 2       1 2V regulated voltage from internal buck Jumper between 1 amp 2       1 2V supply voltage for 1 2V PHY Jum
5. 7       UART channel 6 RS 232 Mode  default   m 1 amp 16 Open  m 2 amp 15 Open  m 3 amp 14 Closed  m 4  amp  13 Closed  UART channel 6 half duplex RS 485 Mode  m 1 amp 16 Open  m 2 amp 15 Closed  m 3 amp 14 Open  m 4 amp 13 Closed  UART channel 7 RS 232 Mode  default   m 5 amp 12 Closed  m 6 amp 11 Closed  m 7 amp 10 Open  m 8 amp 9 Open  UART channel 7 half duplex RS 485 Mode  m 5 amp 12 Closed  m 6 amp 11 Open  m 7 amp 10 Closed  m 8 amp 9 Open    XR17V358 354 EVALUATION BOARD USER   S MANUAL  TABLE 5  SETTINGS FOR RS 232 OR RS 485 MODE FOR MASTER DEVICE    JUMPERS   SWITCH    FUNCTIONS    Enables the RI  signals in RS 232 mode for UART  channels 0 7       Powering Connectivity    REV  1 0 0       COMMENTS    UART channel 0 RS 232 Mode  default   m 1 amp 16 Open  m 2 amp 15 Open  m 3 amp 14 Closed  m 4  amp  13 Closed  UART channel 1 RS 232 Mode  default   5 amp 12 Closed  6 amp 11 Closed  7 amp 10 Open  8 amp 9 Open       Half Duplex RS 485 control select for DE for UART  channel 3    Note  SP3497E is not installed     No jumper installed enables RS 485 driver  Jumper between 2 amp 3 selects RTS  as the half   duplex control output   m Jumper between 1 amp 2 disables the RS 485 driver       Half Duplex RS 485 control select for RE  for UART  channel 3    Note  SP3497E is not installed     m No jumper installed disables RS 485 receiver  Jumper between 1 amp 2 enables the RS 485  receiver  Jumper between 2 amp 3 selects RTS  as the half   duplex control output       Half Dup
6. amp 3 selects RTS  as the half   duplex control output    Note  SP3497E is not installed  Jumper between 1 amp 2 disables the RS 485 drive       Half Duplex RS 485 control select for RE  for UART No jumper installed disables RS 485 receiver  channel 3 Jumper between 1 amp 2 enables the RS 485  receiver    Note  SP3497E is not installed  Jumper between 2 amp 3 selects RTS  as the half   duplex control output    Half Duplex RS 485 control select for DE for UART No jumper installed enables RS 485 driver    channel 4 Jumper between 2 amp 3 selects RTS  as the half   duplex control output    Note  SP3497E is not installed  Jumper between 1 amp 2 disables the RS 485 drive          Half Duplex RS 485 control select for RE  for UART No jumper installed disables RS 485 receiver  channel 4 Jumper between 1 amp 2 enables the RS 485  receiver    Note  SP3497E is not installed  Jumper between 2 amp 3 selects RTS  as the half   duplex control output          2 7 MPIO pins    The MPIO pins of the both the master and slave devices are connected to LEDs or test points on the  evaluation board  Refer to page 6 of the evaluation board schematic for details     Powering Connectivity    XR17V358 354 EVALUATION BOARD USER   S MANUAL REV  1 0 0  3 0 DRIVERS    Software drivers for Windows and Linux are available from Exar  Send an e mail with your driver request to  uarttechsupport exar com     NOTICE    EXAR Corporation reserves the right to make changes to the products contained in this publicati
7. lex RS 485 control select for DE for UART  channel 4    Note  SP3497E is not installed     No jumper installed enables RS 485 driver  Jumper between 2 amp 3 selects RTS  as the half   duplex control output   Jumper between 1 amp 2 disables the RS 485 driver        Half Duplex RS 485 control select for RE  for UART  channel 4    Note  SP3497E is not installed           No jumper installed disables RS 485 receiver  Jumper between 1 amp 2 enables the RS 485  receiver   Jumper between 2 amp 3 selects RTS  as the half   duplex control output          Powering Connectivity    REV  1 0 0 XR17V358 354 EVALUATION BOARD USER   S MANUAL  2 6 Jumper Settings for RS 232 or RS 485 for Slave Device    The following table shows the setting for selecting between the RS 232 or RS 485 modes for the slave device     TABLE 6  SETTINGS FOR RS 232 OR RS 485 MODE For SLAVE DEVICE    JUMPERS   FUNCTIONS COMMENTS  SWITCH    3 3V supply voltage for RS 232 and RS 485 Trans    Jumper between 1 amp 2  ceivers for the slave device       Enable Auto RS 485 Half Duplex Direction Control Jumper between 1 amp 2 enables this feature for all 8  upon power up channels  This feature can be disabled in the software  after power up        Enable IR mode upon power up Jumper between 1 amp 2 enables this feature for all 8  channels  This feature can be disabled in the software  after power up        Half Duplex RS 485 control select for DE for UART No jumper installed enables RS 485 driver  channel 3 Jumper between 2 
8. n  m 8 amp 9 Open  UART channel 1 half duplex RS 485 Mode  m 5 amp 12 Closed  m 6 amp 11 Open  m 7 amp 10 Closed  m 8 amp 9 Open       SW4       Selects between RS 232 and half duplex RS 485  mode for UART channels 2 and 3       UART channel 2 RS 232 Mode  default   m 1 amp 16 Open  m 2815 Open  m 3 amp 14 Closed  m 4  amp  13 Closed  UART channel 2 half duplex RS 485 Mode  m 1 amp 16 Open  m 2 amp 15 Closed  m 3 amp 14 Open  m 4 amp 13 Closed  UART channel 3 RS 232 Mode  default   m 5 amp 12 Closed  m 6 amp 11 Closed  m 7 amp 10 Open  m 8 amp 9 Open  UART channel 3 half duplex RS 485 Mode  m 5 amp 12 Closed  m 6 amp 11 Open  m 7 amp 10 Closed  m 8 amp 9 Open       REV  1 0 0    JUMPERS     SWITCH    Powering Connectivity    XR17V358 354 EVALUATION BOARD USER   S MANUAL    TABLE 5  SETTINGS FOR RS 232 OR RS 485 MODE FOR MASTER DEVICE    FUNCTIONS    COMMENTS       SW6    Selects between RS 232 and half duplex RS 485  mode for UART channels 4 and 5    UART channel 4 RS 232 Mode  default   m 1 amp 16 Open  m 2 amp 15 Open  m 3 amp 14 Closed  m 4  amp  13 Closed  UART channel 4 half duplex RS 485 Mode  m 1 amp 16 Open  m 2 amp 15 Closed  m 3 amp 14 Open  m 4 amp 13 Closed  UART channel 5 RS 232 Mode  default   m 5 amp 12 Closed  m 6 amp 11 Closed  m 7 amp 10 Open  m 8 amp 9 Open  UART channel 5 half duplex RS 485 Mode  m 5 amp 12 Closed  m 6 amp 11 Open  m 7 amp 10 Closed  m 8 amp 9 Open       SW3       Selects between RS 232 and half duplex RS 485  mode for UART channels 6 and 
9. on in order to  improve design  performance or reliability  EXAR Corporation assumes no responsibility for the use of any  circuits described herein  conveys no license under any patent or other right  and makes no representation that  the circuits are free of patent infringement  Charts and schedules contained here in are only for illustration  purposes and may vary depending upon a user   s specific application  While the information in this publication  has been carefully checked  no responsibility  however  is assumed for inaccuracies     EXAR Corporation does not recommend the use of any of its products in life support applications where the  failure or malfunction of the product can reasonably be expected to cause failure of the life support system or  to significantly affect its safety or effectiveness  Products are not authorized for use in such applications unless  EXAR Corporation receives  in writing  assurances to its satisfaction that   a  the risk of injury or damage has  been minimized   b  the user assumes all such risks   c  potential liability of EXAR Corporation is adequately  protected under the circumstances     Copyright 2010 EXAR Corporation  Datasheet January 2010   Send your UART technical inquiry with technical details to hotline  uarttechsupport exar com     Reproduction  in part or whole  without the prior written consent of EXAR Corporation is prohibited     
10. per between 2 amp 3 to use internal buck regulator       1 2V supply voltage for 1 2V Core Jumper between 2 amp 3 to use internal buck regulator             2 5 Jumper Switch Settings for RS 232 or RS 485 for Master Device    The following table shows the setting for selecting between the RS 232 or RS 485 modes for the master  device     TABLE 5  SETTINGS FOR RS 232 OR RS 485 MODE FOR MASTER DEVICE    JUMPERS   FUNCTIONS COMMENTS  SWITCH    3 3V Supply voltage pin for transceivers Not installed  Trace between 1 amp 2        Enable Auto RS 485 Half Duplex Direction Control Jumper between 1 amp 2 enables this feature for all 8  upon power up channels  This feature can be disabled in the software  after power up        Enable IR mode upon power up Jumper between 1 amp 2 enables this feature for all 8  channels  This feature can be disabled in the software  after power up           XR17V358 354 EVALUATION BOARD USER   S MANUAL    JUMPERS     SWITCH       Powering Connectivity    REV  1 0 0    TABLE 5  SETTINGS FOR RS 232 OR RS 485 MODE FOR MASTER DEVICE    FUNCTIONS    COMMENTS       SWw1    Selects between RS 232 and half duplex RS 485  mode for UART channels 0 and 1    UART channel 0 RS 232 Mode  default   m 1 amp 16 Open  m 2 amp 15 Open  m 3 amp 14 Closed  m 4  amp  13 Closed  UART channel 0 half duplex RS 485 Mode  m 1 amp 16 Open  m 2 amp 15 Closed  m 3 amp 14 Open  m 4 amp 13 Closed  UART channel 1 RS 232 Mode  default   m 5 amp 12 Closed  m 6 amp 11 Closed  m 7 amp 10 Ope
    