Home

Split FTNE Series

image

Contents

1. POWER The Power Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room gt See page 4 Wide Angle Louvers The smoothly curved Wide Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room gt See page 4 EZ Vertical Auto Swing up and down This function automatically moves the flaps up and down to distribute air across a room gt See page 4 A Lifestyle Convenience New Powerful Operation New Powerful Operation boosts airflow to maximum volume for a 20 minute period After this the unit automatically returns to its previous settings gt See page 3 Indoor Unit On Off Switch The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged gt See page 6 Cleanliness Wipe Clean Flat Panel ER The flat panel design can be cleaned with only the single pass of a cloth across its smooth surface The flat panel can also be easily removed for more thorough cleaning Comfort Control Programme Dry Function The microprocessor works to rid the room of humidity while maintaining the most consistent temperature possible It automatically controls the temperature and airflow rate Auto Fan Speed The microprocessor automatically controls fan speed to adjust the room temperature to the set temperat
2. 530 8323 Japan CONG TY CO PHAN DAIKIN AIR CONDITIONING VIETNAM e VAN PHONG CH NH Tang 14 15 t a nha Nam A 201 203 C ch Mang Thang 8 P 4 Q3 TP HCM Tel 08 62 504888 Fax 08 62 504 999 e CHI NH NH HA NOI Tang 12 toa nh Ocean Park Tower 1 Dao Duy Anh Quan Dong Da Ha Noi Tel 04 35 657 677 _ Fax 04 35 657 688 e CHI NH NH DA NANG Tang 12 toa nha PVcomBank L A2 1 Dudng 30 4 P H a CuGng Bac Q Hai Chau TP Da Nang Tel 0511 362 4250 Fax 0511 362 4251 www daikin com vn In SN NO o All rights reserved e Specifications designs and other content appearing in this brochure are current as of September 2015 but subject to change without notice Printed in Vietnam 08 15 006 DAV Pe cS O nN a S YO u r CO O Daikin s sophisticated airflow control and low sound pressure levels surround FTNE M you with a cloud of quiet comfort Choosing the right model is easy with a full l lineup of 5 models from 2 0 to 6 0 kW available These stylish compact units series using look just as cool as they feel R 410A is newly launched 2 0 to 3 5 kW Class 5 0 and 6 0 kW Class FTNE20MV1V9 RNE20MV1V9 Model FTNE50MV1V RNESOMV1V Cooling kW DOT Cooling kW 302 Capacity Btu h 7 000 Capacity Btu h 17 150 Model FTNE25MV1V9 RNE25MV1V9 Model FTNE60MV1V RNEGOMV1V Cooling FTNE50 60M Cooling kW 6 3 cna Cneety Btu 21 500
3. T 2 8 Auto Fan Speed o New Powerful O 2 Operation 7 S L 3e Indoor Unit 6 On Off Switch 3 ER Wipe Clean 5 fa Flat Panel O ne 24 Hour Y a On Off Timer 5 Night Set Mode Auto Restart after 0b S Power Failure O Self Diagnosis with an Digital Display Outdoor Unit Functions Worry Free Anti Corrosion Treatment of Outdoor Heat Exchanger Fins Models RNE 20 25 35 50 60M Controllers Specifications Wireless Remote Controller for FTNE20 25 35M Selects fan speed K l Selects mode cooling dry fan only operation 24 Hour On Timer 24 Hour Off Timer Sant Night Set Mode Wireless Remote Controller for FTNE50 60M New Powerful Operation Selects fan speed Selects mode cooling dry fan only operation 24 Hour On Timer 24 Hour Off Timer and Night Set Mode Thae Sets room temperature On Off switch Vertical Auto Swing gt up and down i Cancels On Off Timer Sets clock Sets timer Sets room temperature On Off switch Vertical Auto Swing gt up and down Cancels On Off Timer Sets clock Sets timer Indoor unit FTNE20MV1V9 FTNE25MV1V9 FTNE3SMV1V9 FTNESOMV1V FTNE60MV1V Outdoor unit RNE20MV1V9 RNE25MV1V9 RNE35MV1V9 RNE50MV1V RNE60MV1V 3 26 11 100 Power supply 1 phase 220 240 V 50 Hz Running current i 5 0 Power consumption C
4. FTNE35MV1V9 RNE35MV1V9 i l Cooling kW 3 26 i ei i as Capacity Btu h 11 100 a io sil n J RNE20 25M RNE35M RNE50 60M P Comfortable Airflow Control New Powerful Operation New Powerful Operation boost airflow to maximum volume for a 20 minute period This is convenient when you want to quickly adjust the indoor temperature to the set temperature After this the unit automatically returns to its previous settings New Powerful Operation is available for 5 0 and 6 0 kW models 20 minutes ZEF Power Airflow Dual Flaps Power Airflow Dual Flaps flatten out during cooling operation to deliver air to every part of a room Choosing the low angle sends air right to the corners while choosing the high angle spreads air around the centre Vertical Auto Swing up and down Vertical Auto Swing up and down automatically moves the flaps up and down to distribute air across a room When the air conditioner is turned off the flaps shut automatically so that dust can not enter When you choose the low angle cool air slides off to reach the corners of the room Wide Angle Louvers Wide Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room The louvers can be adjusted to deliver cool air to the corners of a room by hand The louvers cover even a spacious room The angles of the louvers can be adjusted according to where pe
5. OP Model name Capacity Indoor unit FTNE20MV1V9 FTNE25MV1V9 FTNE35MV1V9 FTNE50MV1V FTNE60MV1V Front panel colour Almond white White Airflow rate m min cfm 9 6 339 9 9 349 18 5 653 Fan speed 5 steps and automatic Sound pressure level dB A 37 28 39 33 48 35 48 36 Dimensions mm 283 x 800 x 195 290 x 1 050 x 238 Machine weight kg 9 12 Outdoor unit RNE20MV1V9 RNE25MV1V9 RNE35MV1V9 RNE50MV1V RNE60MV1V Casing colour Ivory white Type Hermetically sealed rotary type Sonptessol Motor output W 593 760 900 1 300 1 957 Type R 410A sean le Charge kg 0 50 0 73 0 91 0 90 Sound pressure level dB A 50 51 54 53 Dimensions HxWxD mm 418 x 695 x 244 550 x 658 x 275 595 x 845 x 300 Machine weight kg 22 25 32 36 40 Operation range CDB 19 4 to 46 Liquid 6 4 Piping connection Gas mm 9 5 12 7 015 9 Drain 18 0 Max piping length m 15 20 Max level difference 12 15 Measurement conditions 1 Cooling capacity is based on indoor temp 27 CDB 19 CWB outdoor temp 35 CDB piping length 5 m 2 Sound pressure levels are measured in an anechoic chamber based on condition 1 above These values are normally somewhat higher during actual operation as a result of ambient conditions Indoor unit No Item FTNE20 25 35 50 60M Remote controller loss prevention with chain KKF917A4 a wW Remote controlle
6. PCRVN1402A Y DAIKIN Y DAIKIN Warning Ask a qualified installer or contractor to install this product Do not try to install the product yourself Improper installation can result in water or refrigerant leakage electrical shock fire or explosion e Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or S p It Ty p e Al r Co n d IT oners contractor to install those parts and accessories Use of unauthorised parts and accessories or FTNE M Series improper installation of parts and accessories can result in water or refrigerant leakage electrical Cooli Only 50 Hz R 410A shock fire or explosion oolng Unly Z e Read the user s manual carefully before using this product The user s manual provides important safety instructions and warnings Be sure to follow these instructions and warnings If you have any enquiries please contact your local importer distributor and or retailer Cautions on product corrosion 1 Air conditioners should not be installed in areas where corrosive gases such as acid gas or alkaline gas are produced 2 If the outdoor unit is to be installed close to the sea shore direct exposure to the sea breeze should be avoided If you need to install the outdoor unit close to the sea shore contact your local distributor DAIKIN INDUSTRIES LTD ae a e HEAD OFFICE Dai ly phan phoi Umeda Center Bldg 2 4 12 Nakazaki Nishi Kita ku Osaka
7. ns to operate lt gt Time A 60 minutes A Off timer turns on Off timer stops air conditioner Cooling operation Room temperature is raised by 0 5 C after 60 minutes Indoor Unit On Off Switch This switch provides convenient manual starting of the indoor unit in the event the wireless remote controller is misplaced or its batteries are not charged FTNE50 60M Indoor Unit On Off Switch Worry Free Design Anticorrosion Treatment of Outdoor Heat Exchanger Fins The outdoor unit s heat exchanger fins are covered with a thin acrylic resin layer to enhance their resistance to acid rain and Salt corrosion A hydrophilic film layer also prevents rust caused by the run off of water droplets The RNE50 60M uses the microchannel heat exchanger MCHE Cross section of anticorrosion treated fin x Hydrophilic film Aluminium Corrosion resistant acrylic resin b r E e 0 Heat exchanger fin Long Piping Length for Flexible Unit Placement The FTNE35 50 60M supports a piping length of up to 20 metres to give flexibility during unit installation This allows the outdoor unit to be placed on a balcony or where it can not be seen Indoor units can also be installed where they do not compromise the decor of a room Max piping length Max level difference FTNE60M Max piping length 20 m Max level difference Functions Comfortable Airflow Zzz Power Airflow Dual Flaps
8. ople are in the room If the indoor unit is not positioned in the centre of the wall the louvers can also be adjusted to the left or right Energy Savings and Quiet Operation COP of 2 97 or More The 2 0 to 6 0 kW models provide a high COP of 2 97 or more An FTNE60M 3 10 air conditioner s COP Coefficient of Performance indicates how efficiently the unit uses energy A higher COP means greater energy efficiency It also means lower electricity consumption so you save money FTNE50M gopa E 2 9 7 Power consumption W FTNE35M 3 09 FTNE25M 3 22 FTNE20M 3 09 The key benefit of split type air conditioners is their quiet Quiet Operation operation This is made possible by the separate indoor and outdoor units The FTNE25M offers a low sound pressure level of 28 dB A for indoor unit operation and 50 dB A for outdoor unit operation 28 dB A Is So Quiet You Can Even Hear Whispers Indoor unit Outdoor unit 20 1 30 40 50 AB A Rustling of leaves Pendulum of a wall clock Library Normal office Based on Examples of Sound Pressure Levels Ministry of the Environment Japan November 12 2002 Night Set Mode Re Pressing the Off timer button automatically selects Night Set Mode This function prevents excessive cooling for a pleasant Sleep Sixty minutes after the Off timer button is pressed the room temperature is raised by 0 5 C Set temp before Cooling Off timer begi
9. r loss prevention with chain KKF917A4 Outdoor unit No Item RNE20 25 35 50 60M 1 Drain plug KKP937A4 Note 1 One set includes five pieces for five units Bp Drain plug KKP937A4 10
10. ure ao Timers 24 Hour On Off Timer This timer can start or stop the air conditioner within a 24 hour period It can be preset in 10 minute steps by pressing the On Off timer button on the wireless remote controller The On timer and Off timer can be used in combination 24 Night Set Mode v4 Pressing the Off timer button automatically selects Night Set Mode This function prevents excessive cooling for a pleasant sleep After 60 minutes the room temperature is raised by 0 5 C gt See page 6 Worry Free Auto Restart after Power Failure Ti The air conditioner memorises the settings for mode airflow temperature etc and automatically returns to them when power is restored after a power failure S1 Self Diagnosis with Digital Display SELF Malfunction codes are shown on the digital display panel of the wireless remote controller for fast and easy maintenance Anti Corrosion Treatment of Outdoor Heat Exchanger Fins The outdoor unit s heat exchanger fins are processed using a special anti corrosion treatment The surface is covered with a thin acrylic resin layer to enhance the fins resistance to acid rain and salt corrosion gt See page 7 Function List Indoor Unit Models n ae FTNE on 20 25 35M 50 60M FII Power Airflow a Dual Flaps E 2 a z Wide Angle Louvers S O Zn Vertical Auto Swing 2 Zl up and down O Programme E Dry Function