image

Contents

1. Metal plate Basic unit T Grounding tiles Expansion unit HOTLAC LA Power Net filter SO L Grounding Earth leakage breaker Insulation Recommended Figure 1 Power wiring example E I O Wiring Procedures Always use the rated input output voltage according to the module specifications Using other voltages may damage the equipment or cause personal injury or fire Use shielded cable and connect the both ends of shields to ground Depending on actual noise environment it could be more effective to connect only one end of shield or not to connect both ends Take a appropriate grounding method accordingly Install AC power cables in separate cable trays or bunches from I O signal or data lines Route the I O lines and data lines as close as possible to the grounded surfaces such as cabinet elements metal bars and cabinets panels E General Wiring Procedures Use copper conductors for all wiring You can use one copper conductor AWG 14 2 1 mm through AWG 22 0 36 mm or two copper conductors AWG 16 1 3 mm through AWG 22 0 36 mm per terminal The suggested torque for terminal connections is 0 5 to 0 6 Nm Use proper cable ferrules for terminals Using improper cable ferrules or connecting bare wires to terminals directly might result in fire Do not turn on the power supply to a broken PL
2. Analog input data Ch 1 12 bits WxXu02 Analog input data Ch 2 Upper 4 bits are always 0 WxXu03 Analog input data Ch 3 WxXu04 Analog input data Ch 4 WYu05 System area Do not write any value WYu06 Analog output data Ch 6 Be sure to write 12 bits data 0 to HFFF WYu07 Analog output data Ch 7 u Unit number 1 to 4 Example Unit 1 Ch 2 WX102 Unit 4 Ch 7 WY407 7 NJI 424B X E Caution Basic unit corresponding to an analog expansion unit Be sure to use with basic unit of software version 1 20 or newer Analog expansion unit is not supported by basic unit of software version 1 12 or older Software version of basic unit is given in WRF051 of special internal output area Conversion data in case input signal is out of range If input data is over the range the conversion data stays at the maximum value If under the range it stays at the minimum value Example Range 0 20mA 25mA input gt OFFFH Example Range 0 10V 15V input gt 0800H Signal level in case written output data is out of range If output data is over the range the signal stays at the maximum value If under the range it stays at the minimum value Output value is signed 16 bits data 8000H to 7FFFH 32768 to 32767 Example Range 0 10V 2000H written gt 10V 10 23V output Example Range 4 20mA FFFFH written gt 4mA output LED indication LED Li
3. NJI 424BX HITACHI Inspire the Next MICRO EH Analog expansion unit Safety Precautions Thank you for purchasing a Hitachi Programmable Logic Controller To operate it safely please read these safety precautions and all the user manuals carefully Please be sure to use the latest versions of the user manuals and keep them at hand of end users for future reference Caution 1 It is not allowed to reprint any part of this manual without permission 2 The content of this manual may be changed without notice 3 While efforts have been made on this manual to be accurate please contact us if any mistakes or unclear part is found m Warranty period and coverage The warranty period is either 18 months after manufacturing date MFG No or 12 months after installation Examination and repair within the warranty period is covered However within the warranty period the warranty will be void if the fault is due to 1 Incorrect use as directed in this manual and the application manual 2 Malfunction or failure of external other devices than this unit 3 Attempted repair by unauthorized personnel 4 Natural disasters The warranty is for the PLC only any damage caused to third party equipment by malfunction of the PLC is not covered by the warranty E Repair Any examination or repair after the warranty period is not covered And within the warranty period any repair and examination which results in information showing the f
4. C Be sure to check all wiring before applying the power Incorrect wiring may damage the equipment or cause fire Do not attempt to disassemble repair or modify any part of the PLC Do not pull on cables or bend cables beyond their natural limit The lines may break Check carefully your PLC program before using Keep PLC modules in their boxes during storage and transport Environmental Conditions Avoid the following locations to install the PLC Excessive dust salty air or conductive materials iron powder etc Direct sunlight Temperature less than 0 C or more than 55 C Humidity less than 5 or more than 95 Dew condensation Direct vibration or impact to the unit Corrosive explosive or combustible gases Water chemicals or oil splashing on the PLC Close to noise emission devices NJI 424B X E Terminal layout and wiring EH A6EAN AC power type Voltage input and output Input and output are configured separately Ch 1 Ch 2 Ch 3 Ch 4 Input voltage 0 to 10V Power supply 100 to 240VAC Output voltage 0 to 10V Power supply 100 to 240VAC Output current fi Pi 0 to 20mA EH D6EAN DC power type Power supply 24VDC NJI 424B X E Wiring and circuit diagram Analog input signal Voltage input Input resister Be sure to use shielded twist pair Signal lines should not be routed close to AC power lines Cu
5. ault was caused by any of the items mentioned above the repair and examination cost are not covered If you have any questions regarding the warranty or repair cost please contact your supplier or the local Hitachi Distributor Depending on failure part repair might be impossible Reference Manual Read the following application manual carefully to use the PLC safely and properly Be sure to keep the latest version Manual number NJI 350 X NJI 465 X Manual name MICRO EH APPLICATION MANUAL MICRO EH BASIC UNIT 20 40 64 points type APPLICATION MANUAL The postfix of the publication number is subject to change for revision General cautions E Definitions and Symbols D DANGER 9 Q Indicates a potentially hazardous situation which if not avoided can result in serious injury or death Indicates a potentially hazardous situation which if not avoided can result in minor to moderate injury or serious damage of product Indicates prohibition Indicates Compulsion lt gt DANGER Do not touch terminals during power ON Failure to observe this caution may cause personal injury Be sure to install external safety devices outside of the PLC like emergency stop circuit or interlock circuit CAUTION Always use the rated power voltage according to the module specifications Using other voltages may damage the equipment or cause personal injury or fire Only qualified pers
6. ding to the manual Using other voltages may damage the equipment or cause personal injury or fire Install an external earth leakage breakers to avoid short circuit accident Always turn off the power supply to the PLC before attempting any of the following Performing any of these acts may result in damage to the PLC or personal injury or malfunction e Mounting or dismounting the basic or expansion unit e Assembling the equipment e Wiring Install net filter specified in table 1 The input and output cable of the net filter should be separated as much as possible Be sure to ground the net filter A shielded and insulated transformer is recommended The basic and expansion unit should be wired to a common power source and powered up together as shown in fig 1 Install a lightning arrester To prevent damage to the equipment as a result of being struck by lightning it is recommended that a lightning arrester be installed for each PLC s power supply circuit Table1 Net filter Item Spec Rated voltage 250 V Rated current 5A Withstand voltage V 1500 V between Terminal and case Insulation resistance M Q min 500VDC 1 min between terminal and case 100 MQ Attenuation frequency Differential mode 40dB 0 5 to 30 range MHz Common mode 40dB 0 15 to 30 Reference EMC filter ZAC2205 00U TDK Enclosure
7. ghting off Blinking POW Power supplied to exp unit No power supplied Power supplied to the next connected unit OK Unit OK No power supplied to basic unit Unit has fault Power up again Cable to basic cable or replace it disconnected E NOTE UL requirements This unit is industrial control equipment for use in hazardous locations class 1 Division 2 Groups A B C and D WARNING EXPLOSION HAZARD SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS DIVISIONZ2 WARNING EXPLOSION HAZARD DO NOT REPLACE MODULES UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KOWN TO BE NON HAZARDOUS WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT CABLE UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS WARNING Fire Explosion and Severe Burn Hazard Do Not Recharge Disassemble Heat Above 212 F 100 C Incinerate Or Expose Contents To Water NJI 424B X
8. onnel shall carry out wiring work Failure to observe this caution may damage the equipment or cause personal injury or fire COMPULSION Be sure to ground the unit Failure to do so may cause malfunction PROHIBITION Do not attempt to disassemble repair or modify any part of the PLC Failure to observe this caution may cause fire or damage of the equipment or malfunction NJI 424B X This equipment must be placed within a suitable enclosure such a cabinet key or tool entry Mount the PLC on a metal plate and install in a cabinet as follows Be sure to ground the cabinet and the metal plate otherwise there is a risk of malfunction Install the PLC as described in user manual Take appropriate measures when installing systems in locations e Subject to static electricity or other forms of noise e Subject to strong electromagnetic field e Close to power supplies Be sure to tighten mounting screws terminal screws and connector screws Check if devices with lock mechanism such as an expansion cable and terminal blocks are locked properly E Power Wiring Procedures Appropriate emergency circuitry interlock circuitry and similar safety measures should be added to the system Appropriate safety measures should be included in the system to ensure safety in the event of abnormal signals caused by broken wires or momentary power interruptions Always use the rated power voltage accor
9. rrent input Analog output signal Voltage output Be sure to use shielded twist pair cable Current output In some cases capacitor 2000pF ji or less is effective In some cases capacitor 0 47 uF hi NJI 424B X E Data conversion Analog input 0 to 10V Range 4096 mode OFFFH 4095 4000 mode OFAOH 4000 4000 mode 4096 mode lt 10V OFAOH 4000 OFFFH 4095 O O07FFH 2047 amp 5V 07DOH 2000 O7FFH 2047 07D0H 2000 ov 0000H 0 0000H 0 Resolution 0 0025 V approx 0 00244 V 0 5 10 0 to 10V Range 07FFH 2047 07D0H 2000 4000 mode 4096 mode lt 10V 07DOH 2000 O7FFH 2047 O amp OV OOOOH 0 OOOOH 0 10 _0000H 0 40v 0830H 2000 0800H 2048 Resolution 0 00125 V approx 0 00122 V 0830H 2000 O800H 2048 0 to 20 mA Range OFFFH 4095 OFAOH 4000 4000 mode 4096 mode 20mA OFAOH 4000 OFFFH 4095 3 10mA 07DOH 2000 O7FFH 2047 O7FFH 2047 07D0H 2000 OmA 0000H 0 OOOOH 0 Resolution 0 005mA approx 0 00488mA mA 0 10 20 4 to 20 mA Range OFFFH 4095 Sener ROO 4000 mode 4096 mode 20mA OFAOH 4000 OFFFH 4095 S 12mA 07DOH 2000 O7FFH 2047 07FFH 2047 S 07D0H 2000 4mA 0000H 0 OOOOH 0 Resolution 0 004mA approx 0 00391mA mA 0 4 12 20 NJI 424B X Analog outp
10. ut 0 to 10V Range 10 4000 mode 4096 mode lt 10V OFAOH 4000 OFFFH 4095 fe amp 5V 07DOH 2000 O7FFH 2047 5 P OV OOOOH 0 0000H 0 Resolution 0 0025 V approx 0 00244 V 9 07D0H 07FFH OFAOH OFFFH 2000 2047 4000 4095 0 to 20 mA Range mA 20 l 4000 mode 4096 mode 20mA OFAOH 4000 OFFFH 4095 10 3 10mA 07DOH 2000 O7FFH 2047 2 OmA OOOOH 0 0000H 0 Resolution 0 005mA approx 0 00488mA 0 07D0H O7FFH OFAOH OFFFH 2000 2047 4000 4095 4 to 20 mA Range ae 4096 mode 20 4000 mode 4096 mode 20mA OFAOH 4000 OFFFH 4095 lg 12mA 07D0H 2000 07FFH 2047 4mA 0000H 0 0000H 0 7 Resolution 0 004mA approx 0 00391mA 2 07D0H 07FFH OFAOH OFFFH 2000 2047 4000 4095 i uano NJI 424B X E Range configuration Analog input Common for all channels Dip switch Remarks Factory default Factory default Analog output Common for all channels Remarks Factory default Conversion mode Mode Remarks 4 096 HOFFF Note Power up again after adjusting 4 000 HOFAO Sw5 Be sure to set off Sw7 Be sure to set off Sw8 Be sure to set off E O assignment Data allocation 1 0 assignment FUNO WXu00 System area Factory default WxXu01