1. Residential Electric Heat Pump Water Heater Installation Instructions and Use amp Care Guide To obtain technical warranty or service assistance during or after the installation of this water heater call toll free 1 877 817 6750 When calling for assistance please have the following information ready 1 Model number 2 7 Digit product number 3 Serial number 4 Date of installation 5 Place of Purchase Table of Contents Water Heater Safety Installing Your Water Heater Consumer Information Consumer Responsibilities Unpacking Instructions Location Requirements Confined Space Installation Water System Piping Temperature amp Pressure Relief Valve Electrical Requirements Installation Checklist Operating Your Water Heater Before Using Water Temperature Regulation Adjusting the User Interface Module Operational Mode Operational Conditions Maintenance of Your Water Heater Temperature and Pressure Relief Valve Draining and Flushing Heating Element Replacement Cleaning the Heat Pump Diagnostic Codes Troubleshooting Chart Repair Parts Illustration WATER HEATER SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will foll
2. No communication between 1 Contact a qualified person to service the unit ERROR mainboard and user interface board 18 DIAGNOSTIC CODES ELECTRONIC 1 POWER ANODE ERROR 0 9 CAN BE 0 9 Indicates the power anode is 1 Contact a qualified person to service the unit not operating properly NOTE The diagnostic codes listed above are the most common If a diagnostic code not listed above is displayed contact Residential Technical Assistance referencing the number on the front of this manual TROUBLESHOOTING CHART PROBLEM POSSIBLE CAUSE S CORRECTIVE ACTION NO HOT WATER INSUFFICIENT HOT WATER SLOW HOT WATER RECOVERY HIGH OPERATION COSTS DRIP FROM TEMPERATURE amp PRESSURE RELIEF VALVE Warning Do not plug or cap T amp P discharge pipe No power to the water heater power button not lit Unit in standby power button RED Unit in Vacation mode High temperature limit switch open Hot water usage pattern exceeds the capability of the water heater in current mode Non functioning upper temperature sensor Temperature set point too low Air filter dirty Hot water usage pattern exceeds the capability of the water heater in current mode Water connections to unit reversed Heat lost through long run of exposed pipe Hot water leak at faucet or piping Non functioning heating element Sediment or scale build up in tank Temperature set point too high Air filter dirty Electric mode selec
3. section 3 The heat pump compressor or fan running Stacking Stacking occurs when a series of short draws of hot water 3 gallons or less are taken from the water heater tank This causes increased cycling of the heat pump and or heater elements and can result in increased water temperatures at the hot water outlet An anti scald device is recommended in the hot water supply line to reduce the risk of scald injury 15 MAINTENANCE OF YOUR WATER HEATER Temperature and Pressure Relief Valve AWARNING Explosion Hazard If the temperature and pressure relief valve is dripping or leaking have a qualified person replace it Examples of a qualified person include licensed plumbers authorized electric company personnel and authorized service personnel Do not plug valve Do not remove valve Failure to follow these instructions can result in death or explosion Manually operate the temperature and pressure relief valve at least once a year to make sure it is working properly To prevent water damage the valve must be properly connected to a discharge line which terminates at an adequate drain Standing clear of the outlet discharged water may be hot slowly lift and release the lever handle on the temperature and pressure relief valve to allow the valve to operate freely and return to its closed position If the valve fails to completely reset and continues to release water immediately disconnect the
4. that may cause excessive restriction to water flow is not recommended e Use only 95 5 tin antimony or other equivalent solder Any lead based solder must not be used e Piping that has been treated with chromates boiler seal or other chemicals must not be used e Chemicals that may contaminate the potable water supply must not be added to the piping system Condensate Drain Line Installation Install two 1 2 PVC discharge lines from the condensate drains located on the right side near the back The lines should terminate a maximum of six inches above an adequate drain Do not discharge the condensate drain lines into the metal drain pan If no floor drain is available or the drain is above the level of the condensate line a condensate pump should be installed These pumps are available from local distributors When installing the drain line note the following e Plastic pipe or tubing must be used to connect the condensate drain to a suitable drain or condensate pump e Condensate drain lines should be installed in conditioned areas only Install approved insulation on the condensate drain lines to prevent condensation from forming on the outside of the drain lines Condensation drain lines installed in areas that are subject to freezing temperatures should be wrapped with a nationally recognized listed heat tape Install per manufacturer s instructions e Do not connect condensate drain lines with other drain or dis
5. Mode and turn off power to the water heater at the circuit breaker fuse box Locate the screw securing the filter panel to the heat pump shroud and loosening it Remove slide the filter from the unit If you are replacing the filter skip to step 4 To clean the filter use a vacuum with a hose attachment to remove any dust or debris 4 Place the new or cleaned filter into the water heater and secure the filter to the shroud with the screw loosened earlier NOTE The guides slots when inserting the filter into the water heater 5 Restore power to the water heater and press the power button to turn the water heater on NOTE the water heater will conduct a system diagnostic prior to operation Inspection Cleaning of the Condensate Drain Pan amp Condensate Drain Lines IMPORTANT Before attempting to clean or replace the condensate drain pan or lines press the power button to place the water heater in Standby Mode and shut off power to the water heater at the circuit breaker fuse box 1 Remove the access panel fan side by loosening the screws securing it to the unit 2 Check the condensate drain pan and drain lines for any dirt or debris that might interfere with proper drainage Wipe out any dirt or debris with a damp cloth 3 Once the condensate drain pan and lines have been inspected cleaned secure the access panel to the water heater 4 Restore power to the water heater and press the power button to turn the water
6. birth defects or other reproductive harm This appliance can cause low level exposure to some of the substances included in the Act IMPORTANT The heat pump portion of this water heater uses R 134a refrigerant See the data plate on the heat pump jacket for the charge level INSTALLING YOUR WATER HEATER Consumer Information This water heater should be installed in accordance with the local code authority having jurisdiction the power company or electric utility and this installation manual In the absence of local code requirements follow the regulations set forth in the latest edition of The National Electric Code NFPA 70 This is available from the following National Fire Protection Association 1 Batterymarch Park Quincy MA 02269 American National Standards Institute 1430 Broadway New York NY 10018 Check your phone listings for the local authorities having jurisdiction over your installation Consumer Responsibilities This manual has been prepared to acquaint you with the installation operation and maintenance of your electric heat pump water heater and to provide important safety information in these areas We urge you to read all of the instructions thoroughly before attempting the installation or operation of this water heater This manual should be kept for future reference The manufacturer of this water heater will not be liable for any damages caused by failure to comply with the installation and op
7. electrical power close the cold water inlet valve and call a qualified person Draining and Flushing It is recommended that the tank be drained and flushed every 6 months to remove sediment which may build up during operation The water heater should be drained if being shut down during freezing temperatures To drain the tank perform the following steps 16 Figure 12 Temperature and Pressure Relief Valve y Manual Relief ia Discharge line to drain Place the water heater in Standby Mode by pressing the power button on the user interface module Turn off the power to the water heater at the circuit breaker fuse box Open a nearby hot water faucet until the water is no longer hot Close the cold water inlet valve Connect a hose to the drain valve and terminate it to an adequate drain or external to the building Open the water heater drain valve and allow all of the water to drain from the tank Flush the tank with water as needed to remove sediment 7 Close the drain valve refill the tank open the cold water inlet valve and restart the heater as directed in this manual IMPORTANT Do not turn on power to the water heater unless it is completely filled with water To ensure that the tank is full open a hot water faucet and allow the water to run until the air is purged and the water flows uninterrupted from the faucet 8 Press the power button to turn the water heater on NOTE The water heater will co
8. functioning OPEN OR AD ERROR LOWER TEMP 1 Lower Temperature Sensor Contact a qualified person to service the unit SENSOR SHORT OR is not functioning OPEN OR AD ERROR DISCHARGE TEMP 1 Discharge Temperature Contact a qualified person to service the unit SENSOR SHORT OR Sensor is not functioning OPEN OR AD ERROR COIL TEMP 1 Coil Temperature Sensor is Contact a qualified person to service the unit SENSOR FAULT not functioning OR AD ERROR MAIN CIRCUIT BOARD 1 Main Circuit Board is not 1 Contact a qualified person to service the unit FAULT functioning HIGH TEMP 1 Water temperature in unit 1 See Safety Shut off section LOCKOUT has exceeded 190 F CONDENSATE 1 Condensate pump failure 1 Check to see if accessory condensate pump is plugged in and DRAIN has power Also check circuit breaker fuse box and GFCI if ALARM used if error persists proceed to the next step 2 Check condensate pump outlet tube for blockage if error persists If Accessory Condensate proceed to the next step _ Pump is Installed 3 Check control wire connections to condensate pump If error persists proceed to the next step 4 Replace accessory condensate pump If error persists contact a Qualified Person LOW WATER 1 Not enough water in the 1 Fill Completely Open all hot water taps in home and run until LEVEL ALARM tank water uninterrrupted by air flows from all open hot water Tank not full taps COMMUNICATION 1
9. this water heater is equipped with Dry Fire protection circuitry be sure tank is completely filled with water before applying electrical power to the water heater Reconnect electrical power to the water heater at the circuit breaker fuse box Press the power button to turn the water heater on Set the desired water temperature and operating mode NOTE The water heater will conduct a system diagnostic approximately 8 minutes prior to operation Routine Preventive Maintenance At least monthly a visual inspection should be made of the following e Air Filter Remove and inspect clean if needed and reinstall e Condensate drain pan and condensate lines e The lower metal drain pan for standing water which may indicate a clogged condensate drain pan condensate lines or plumbing leak e Leaking or damaged water piping e Presence of corrosive materials in the installation area e Presence of combustible materials near the water heater e After servicing this water heater check to make sure it is working properly See Operating Your Water Heater section of this manual IMPORTANT If you lack the necessary skills required to properly perform this visual inspection you should not proceed but get help from a qualified person Cleaning the Heat Pump Air Filter Cleaning Replacement IMPORTANT Before attempting to clean or replace the air filter press the power button to place the water heater in Standby
10. to water in any way Do not attempt to repair a unit subjected to flood conditions Water heaters subjected to flood conditions or any time the unit has been submerged in water require replacement of the entire water heater Safety Shut off ECO This water heater is designed to automatically shut off in the event that the water temperature exceeds 190 F or 87 8 C A temperature limit switch or ECO Energy Cut Off is used to shut off the power to the system if the water temperature exceeds 190 F or 87 8 C See Water Temperature Regulation section To reset the ECO disconnect power at the circuit breaker fuse box then remove the upper access panel Reset the ECO by firmly pushing in the red reset button located on the ECO block If the ECO continues to shut off the water heater contact a qualified person for service Water Temperature Regulation AWARNING Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded Feel water before bathing or showering Temperature limiting valves are available The water heater is adjusted to a temperature setting of no higher than 120 F when it is shipped from the factory Water temperature can be regulated by adjusting the User Interface Module to the preferred setting as shown in Adjusting the User Interface Module Operational Mode The preferred starting point is 120 F The
11. E The heat pump s fan will not turn on if the incoming water temperature is less than 59 F and or the ambient air temperature is above 109 F or below 45 F Should the internal diagnostics detect a problem with the heat pump an error message will be displayed 12 Set the operational mode For standard installation the Hybrid Mode offers the best combination of efficiency and hot water delivery For detailed descriptions of all operational modes see Adjusting the User Interface Module Operational Modes section Sse ON Reattach the left louvered access panel to the water heater Figure 9A Junction Box Black Wire Conduit Field Connection Red Wire Figure 9B Condensate Pump Wiring Condensate Pump Wiring Loop 18 AWG White Loop Located Behind Junction Oa White Wires From Water Heater Wires to Condensate Pump Overflow Shut Off Switch 18 AWG or Larger Figure 10 Wiring Diagram Overload Protection Circuit Breaker Approved Connectors L1 s L2 oe To 240v 1 Phase Power supply Electrical Service ground Connecting the Condensate Pump Overflow Shut Off Switch 1 Turn off power to the electrical wiring for the water heater at the circuit breaker fuse box 2 Locate the white 18 AWG wire loop behind the field wiring junction box See Figure 9B Cut the loop and strip insulation off of the two ends Measure the distance from the field wiring junction bo
12. EATER THAN THE DIAMETER OF THE WATER HEATER NOTE The water heater shall be located so it is not subject to physical damage by moving vehicles or area flooding Figure 3 Residential Garage Installation Vehicle Stop State of California NOTE The water heater must be braced anchored or strapped to avoid moving during an earthquake Contact local utilities for code requirements in your area visit http www dsa dgs ca gov or call 1 916 445 8100 and request instructions Confined Space Installation The heat pump water heaters covered in this manual require a minimum of 750 cubic feet of installation space When a space meeting this minimum requirement is not available these units may be installed in spaces with less than 750 cubic feet confined spaces when provisions are made by installing an accessory Outlet Duct Kit and or louvered grills as described in this section Inlet air will be derived from an alternate location inside the building structure through one or more louvered grills or through a fully louvered door leading into the confined space The alternate location from where inlet air will be derived must provide a minimum of 750 cubic feet of space when using this installation method When the Outlet Duct Kit is installed outlet air from the unit is redirected to an alternate location The alternate location to where outlet air will be redirected must also provide a minimum of 750 cubic feet of space Other config
13. ON Element Functioning Icon Water Heater Water Heater o Status LA a mul Icon Heat Pump aml Functioning Icon Mode Status i Indicator IN HEAT PUMP ON LCD Control B Panel Lock Icon Temperature Down Decrease Button Temperature Up Increase Button S44 A Fahrenheit Celsius Temperature Display Button LCD Display Panel Lock Button Power Button On Green Standby Red Operational Conditions Powered Anode Operation To shelter the glass lined water tank from corrosion through electrolysis this water heater is equipped with a non sacrificial powered anode which should not need to be replaced under normal operating conditions NOTE The powered anode operates only when electrical power is applied If the powered anode malfunctions it should be replaced by a qualified technician IMPORTANT If a faulty powered anode is not repaired or has been removed permanently then all warranties are void Water Heater Sounds During the normal operation of the water heater sounds or noises may be heard These noises are common and may result from the following 1 Normal expansion and contraction of metal parts during periods of heat up and cool down 2 Sediment buildup on or around the elements could create varying amounts of noise and may cause premature tank failure Drain and flush the tank as directed under the Draining and Flushing
14. be necessary to switch to Hybrid Mode HYBRID ay EFFICIENCY Electric Mode The water heater functions as a conventional electric unit relying totally on the elements to heat the water in the tank This mode may be useful in winter to eliminate the output of cold air from the unit Vacation Mode The controller adjusts the water temperature to approximately 60 F This mode is recommended when the water heater is not in use for a long period of time This mode minimizes energy consumption and prevents the water heater from freezing during cold weather NOTE To activate the Vacation Mode touch the vacation button To deactivate Vacation Mode touch the vacation button IMPORTANT The anode protecting the tank requires power to the unit to operate Do not shut off power to the unit for extended periods of time If power must be turned off for an extended period of time drain the tank completely ELECTRIC O VACATION 14 Other Controls a Lock Holding this button for more than 3 seconds switches the lock mode on or off When the User Interface Module is locked a symbol and Lock text will be visible on the display see Figure 11 F C The button switches the display to show the set temperature in Fahrenheit or Celsius Figure 11 User Interface Module Operational Mode Buttons T LEN ELECTRIC Water Temperature Set Point EFFICIENCY HYBRID VACATI
15. c elements only function during high demand periods See Adjusting the User Interface Module Operational Mode section The more often the unit operates using the heat pump rather than the elements the more efficient the unit will be The tank capacity of this heat pump water heater is sized to maximize the use of the heat pump to deliver hot water at a lower cost as compared to heat pump waters with lower tank capacities 50 gallons or less The HPWH uses about half the electricity of a comparably sized conventional electric water heater when operating in the Efficiency Mode and provides up to ton cooling capacity and dehumidification It is designed for indoor residential applications for installation in a basement garage or utility room See Location Requirements section Figure 1 Heat Pump Water Heater Basic Operation Ambient Air Cool Dehumidified Air Heat Pump Transfers heat from ambient air to Heat Exchanger Upper Element 4500 Watt Heat Exchanger Heat Transfer Coils Lower Element 2000 Watt Unpacking the Water Heater AWARNING Excessive Weight Hazard Use two or more people to move and install water heater Failure to do so can result in back or other injury Removing Packaging Materials IMPORTANT Do not remove cover or deface any permanent instructions labels or the data label from either the outside of the water heater or on the
16. charge lines into a single common pipe or line Each line condensate drain line temperature and pressure relief valve discharge pipe etc should be independently run to an adequate drain e Slope the condensate drain lines toward the inside floor drain or condensate pump The condensate drain lines and connections to the drain piping must comply with all local codes e Use appropriate primer and glue to cement the condensate drain lines to the heat pump drain pan NOTE The heat pump drain pan is ABS and the two condensate drain pipes should be PVC e Ifa condensate pump is installed it should shut off the heat pump in the event the condensate pump fails or the float switch in the pump activates See Condensate Pump Installation section Closed System Thermal Expansion AWARNING Explosion Hazard If the temperature and pressure relief valve is dripping or leaking have a qualified person replace it Examples of a qualified person include licensed plumbers authorized electric company personnel and authorized service personnel Do not plug valve Do not remove valve Failure to follow these instructions can result in death or explosion Most public water systems in North America are required to prevent water flowing from points of use residences businesses etc back into the supply system in order to maintain water quality To accomplish this back flow preventers such as check valves are install
17. ction is at the bottom and that the hot connection is at the top Insulate exposed piping Repair hot water leaks Drain and flush tank Water conditioning may be required to minimze build up Check water supply inlet pressure If higher than 80 PSIG install a pressure reducing valve 50 60 PSIG is the recommended pressure See Closed System Thermal Expansion section Replace the Temperature amp PressureRelief Valve When first started the water heater takes about 8 minutes to complete a diagnostic routine Contact a qualified person for service 19 REPAIR PART ILLUSTR D REPAIR PARTS Repair parts may be ordered through your plumber local distributor home improvement center or by calling 1 800 527 1953 When ordering repair parts always give the following information 1 Model serial and product number 2 Item number 3 Parts description 20 ATION REPAIR PARTS LIST Energy Cut Off ECO Switch e Temperature amp Pressure Relief Valve T amp P e PoweredAnoderos o User interface modue SSCS NOT SHOWN NOTES 22 WHIRLPOOL is a registered trademark of Whirlpool U S A 2010 Whirlpool Corporation All rights reserved Manufactured under license by American Water Heater Company Tennessee Warranty provided by Manufacturer
18. e of both the valve and discharge line Temperature Pressure Relief Valve and Pipe Insulation 1 Locate the temperature and pressure relief valve on the water heater also known as a T amp P relief valve See Figure 6 2 Locate the slit running the length of the T amp P relief valve insulation 3 Spread the slit open and fit the insulation over the T amp P relief valve See Figure 7 Apply gentle pressure to the insulation to ensure that it is fully seated on the T amp P Re lief Valve Once seated secure the insulation with duct tape electrical tape or equivalent IMPORTANT The insulation and tape must not block the discharge opening or hinder access to the manual relief lever Figure 7 Ensure a discharge pipe is in stalled into the T amp P valve discharge opening per the instructions in this manual Figure 7 T amp P Relief Valve Insulation T amp P Relief Valve Insulation Manual Relief Lever T amp P Relief Valve T amp P Relief Valve Drain Line Locate the hot water outlet amp cold water inlet pipes to the water heater Locate the slit running the length of a section of pipe insulation Spread the slit open and slip the insulation over the cold water inlet pipe Apply gentle pressure along the length of the insulation to ensure that it is fully seated around the pipe Also ensure that the base of the insulation is flush with the water heater Once seated secure the insulation with duct tape electr
19. e the lines of any excess air and sediment keep the hot water faucet open for 3 minutes after a constant flow of water is obtained Close the faucet and check all connections for leaks Massachusetts Install a vacuum relief in cold water line per section 19 MGL 142 Vacuum Relief Valve when required by local code one Cold Water Inlet Valve Inlet Untempered Water Outlet Outlet Valve Follow the Mixing Valve s Pressure Reducing Valve PRV should be installed where the water supply enters the residence When installed PRVs create a closed water system a thermal expansion tank must be installed Tempered Water to Fixtures Cold Water Outlet In a closed system use a thermal expansion tank See Closed System Thermal Expansion section Cold Drain Line 3 4 ID Minimum 6 Maximum Drain Air Gap Shut off Valve If an adequate drain is not available for the condensate drain lines then a condensate pump must be used DO NOT discharge the condensate drain lines into the metal drain pan Please note the following e The system should be installed only with piping that is suitable for potable drinkable water such as copper CPVC or polybutylene This water heater must not be installed using iron piping or PVC water piping e Use only pumps valves or fittings that are compatible with potable water e Use only full flow ball or gate valves The use of valves
20. ed in the water line going to each point of use Typically the back flow preventer will be installed at the water meter or inside a building where the supply line enters the building This device allows water to flow into the residence but does not allow it to flow back into the water supply This creates what is known as a Closed System As water is heated by the water heater the water in the system attempts to expand but has nowhere to go resulting in an increase in pressure This increase in pressure in the system may cause the temperature pressure relief valve to open to relieve the pressure Water will drip from the temperature and pressure relief valve Premature tank failure will result if this condition is not corrected To prevent this condition a properly sized thermal expansion tank should be installed in the cold water supply to the water heater as shown in Figure 4 Failure to install a properly sized expansion tank in a closed system will void the warranty on the water heater in the event of tank failure It is important to follow the thermal expansion tank manufacturers installation instructions and to adjust the expansion tank pressure to match the water supply pressure Contact a plumbing service agency or your retail supplier regarding the installation of a thermal expansion tank Temperature and Pressure Relief Valve AWARNING Explosion Hazard If the temperature and pressure relief valve is dripping or leaki
21. ended as a best installation practice The water heater should be located in an area not subject to freezing temperatures Water heaters located in unconditioned spaces i e garages basements etc may require the water piping condensate piping and drain piping to be insulated to shelter against freezing The drain and controls must be easily accessible for operation and service The site location must be free from any corrosive elements in the atmosphere such as sulfur fluorine and chlorine These elements are found in aerosol sprays detergents bleaches cleaning solvents air fresheners paint and varnish removers refrigerants and many other commercial and household products In addition excessive dust and lint may affect the operation of the unit See Cleaning the Filter section The ambient air temperature must also be considered when installing this unit In Efficiency Mode the ambient air temperature must be above 45 F and below 109 F If the ambient air temperature falls outside these upper and lower limits the electrical elements will activate to meet the hot water demand and the heat pump does not operate NOTE Local codes and requirements in your area may require the installation of your water heater be accomplished in a way that the bottom element is elevated from the floor at least 18 inches Ensure that a platform capable of supporting the combined weight of the water heater and water is used Table 1 Ca
22. erating instructions outlined in this manual If you lack the necessary skills required to properly install this water heater or you have difficulty following the directions you should not proceed but have a qualified person perform the installation of this water heater Examples of a qualified person include licensed plumbers authorized electric company personnel and authorized service personnel Massachusetts code requires this water heater to be installed in accordance with Massachusetts 248 CMR 2 00 State Plumbing Code and 248 CMR 5 00 A data plate identifying your water heater can be found adjacent to the upper element door When referring to your water heater always have the information listed on the data plate readily available to include the model and serial number Retain your original receipt as proof of purchase Basic Operation Fundamentals The Heat Pump Water Heater HPWH is an integrated heat pump water heater unit having an 850 watt compressor and external coil heat exchanger with backup electric elements See Figure 1 When in Efficiency Mode the heat pump draws heat from the ambient air in the room and transfers it to the water in the tank through the coil heat exchanger While in Electric Mode the water heater functions like a standard electric water heater relying on the electric elements to heat the water A Hybrid Mode is available that relies primarily on the heat pump to heat the water while the electri
23. facturer s Installation Instructions Set to 120 F Condensate Drain Lines 3 Some local codes may require and the manufacturer of this water heater recommends installing a mixing valve or an anti scald device in the domestic hot water line as shown in Figure 5 These valves reduce the point of use temperature of the hot water by mixing cold and hot water and are readily available Contact a licensed plumber or the local plumbing authority for more information 4 Some local codes may require and the manufacturer of this water heater recommends installing a pressure reducing valve PRV in the cold water inlet line where it enters the residence as shown in Figure 5 5 If installing the water heater in a closed water system install an expansion tank in the cold water line as specified under Closed System Thermal Expansion 6 Install a shut off valve in the cold water inlet line It should be located close to the water heater and be easily accessible Know the location of this valve and how to shut off the water to the heater 7 Install a discharge line from the temperature and pressure relief valve in the opening marked T amp P RELIEF VALVE See Figure 5 and the Temperature and Pressure Relief Valve section 8 After piping has been properly connected to the water heater open the nearest hot water faucet Then open the cold water shut off valve and allow the tank to completely fill with water To purg
24. heater on NOTE The water heater will conduct a system diagnostic prior to operation ws 17 DIAGNOSTIC CODES UPPER ELEMENT 1 Upper element is not 1 Turn off power at the circuit breaker fuse box and check for CONNECT functioning a loose connection at the element For access directions FAULT see Heating Element Replacement section If error persists proceed to the next step Replace non functioning element See Heating Element Replacement section LOWER ELEMENT 1 Lower element is not Turn off power at the circuit breaker fuse box and check for CONNECT functioning a loose connection at the element For access directions FAULT see Heating Element Replacement section If error persists proceed to the next step Replace non functioning element See Heating Element Replacement section IMPORTANT Using an element greater than 2000 watts in place of the lower element will damage the water heater and void the warranty HEAT PUMP 1 Heat Pump compressor is Contact a qualified person to service the heat pump CONNECT not functioning FAULT FAN 1 Heat Pump fan is not Contact a qualified person to service the unit CONNECT functioning FAULT AMBIENT TEMP 1 Ambient Temperature Contact a qualified person to service the unit SENSOR SHORT OR Sensor is not functioning OPEN OR AD ERROR UPPER TEMP 1 Upper Temperature Sensor Contact a qualified person to service the unit SENSOR SHORT OR is not
25. ical tape or equivalent Repeat steps 5 and 6 for the hot water outlet pipe Add additional sections of pipe insulation as needed Electrical Requirements AWARNING Electric Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock AWARNING Fire Hazard Use 10 gauge solid copper wire Use a UL listed or CSA approved strain relief Connect ground wire to green ground wire Failure to do so can result in death fire or electrical shock If you lack the necessary skills required to properly install the electrical wiring to this water heater do not proceed but have a qualified electrician perform the installation When making the electrical connections always make sure e The electrical service provides 240 VAC to the water heater for proper operation DO NOT use 208 VAC e Wire sizes and connections comply with all applicable codes or in the absence of local or state codes follow NFPA 70 the National Electrical Code current edition e Wiring enclosed in approved conduit if required by local codes e The water heater and electrical supply are properly grounded e The electrical supply has the proper overload fuse or breaker protection Figures 9A 9B amp 10 are provided as reference drawings Always reference the wiring diagram located on the water heater for the correct electrical connectio
26. ided and marked for this purpose in the water heater and orient it or provide tubing so that any discharge from the valve exits only within 6 inches above drain or at any distance below the structural floor and does not contact any live electrical part The discharge opening must not be blocked or reduced in size under any circumstance IMPORTANT Only a new temperature and pressure relief valve should be used with your water heater Do not use an old or existing valve as it may be damaged or not adequate for the working pressure of the new water heater Do not place any valve between the relief valve and the tank The Temperature amp Pressure Relief Valve e Shall not be in contact with any electrical part Shall be connected to an adequate discharge line Shall not be rated higher than the working pressure shown on the data plate of the water heater The Discharge Line e Shall not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line e Shall not be capped blocked plugged or contain any valve between the relief valve and the end of the discharge line e Shall terminate a maximum of six inches above a floor drain or external to the building In cold climates it is recommended that the discharge pipe be terminated at an adequate drain inside the building e Shall be of material listed for hot water distribution e Shall be installed to allow complete drainag
27. inside of water heater panels e The water heater must NOT be placed on its side It should be transported and stored in an upright position e Remove exterior packaging and place installation components aside e Inspect all parts for damage prior to installation and start up e Completely read all instructions before attempting to assemble and install this product e After installation dispose of recycle all packaging materials Location Requirements Site location Select a location near the center of the water piping system The unit must be installed indoors and in a vertical position on a level surface The flooring beneath the water heater must be able to support the weight of the water heater when filled with water See Table 1 IMPORTANT The water heater must have unresticted airflow and requires a minimum installation space of 750 cubic feet As an example a room that has an eight foot tall ceiling and is 10 feet long by 9 1 2 feet wide would contain 760 cubic feet See The Confined Space Installation section of this manual for installing the water heater in spaces of less than 750 cubic feet NOTE To ensure optimal performance and efficiency a minimum clearance of six 6 inches from the back left and right sides of the water heater must be maintained A minimum of 12 inches from the front of the unit should be maintained for control access Service clearances of three 3 feet from the left and right sides are recomm
28. nduct a system diagnostic prior to operation oO ak N If the water heater is going to be shut down for an extended period the drain valve should be left open Heating Element Replacement AWARNING Electric Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock Replacement heating elements must be of the same style and voltage wattage rating as the ones originally in the water heater This information can be found on the flange or terminal block of the element or on the water heater data plate IMPORTANT Before replacing any element confirm that you have the correct replacement element wattage This water heater has a 4500 watt upper element and a 2000 watt lower element DO NOT replace the element s with a wattage different than the ones specified for the upper and or lower element IMPORTANT Using an element greater than 2000 watts in place of the lower element will damage the water heater and void the warranty 1 Press the power button on the user interface module to place the water heater in Standby Mode 2 Turn off the power to the water heater 3 Drain the water heater as directed in the Draining and Flushing section Figure 13 Figure 14 10 11 12 13 14 15 16 Remove the access cover s then remove the foam insulation block Remove the protective plastic cover s
29. ng have a qualified person replace it Examples of a qualified person include licensed plumbers authorized electric company personnel and authorized service personnel Do not plug valve Do not remove valve Failure to follow these instructions can result in death or explosion Figure 6 Temperature and Pressure Relief Valve Installation Temperature and Pressure Relief Valve lt Discharge Pipe Do Not Plug or Cap _ gt Drain Pan 2 1 2 Depth Maximum and 2 Inches wider than the water heater Drain Line 3 4 ID Minimum For protection against excessive pressures and temperatures a temperature and pressure relief valve must be installed in the opening marked T amp P RELIEF VALVE See Figure 5 To reduce the risk of excessive pressures and temperatures in this water heater install temperature and pressure relief protective equipment required by local codes but no less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of the production of listed equipment or materials as meeting the requirements for Relief Valves and Automatic Shutoff Devices for Hot Water Supply Systems ANSI 221 22 latest edition This valve must be marked with the maximum set pressure not to exceed the marked maximum working pressure of the water heater Install the valve into an opening prov
30. ns and connect the electrical supply to the water heater in accordance with local utility requirements and codes When installing the electrical wiring to the water heater 1 Although this water heater is equipped with Dry Fire protection circuitry be sure tank is completely filled with water and all air is purged from the tank before making any electrical connections See Draining and Flushing Section 2 Turn off power to the electrical wiring for the water heater at the circuit breaker fuse box 3 Remove the left louvered access panel when facing the water heater by loosening the screws securing it to the water heater See figure 8 4 Loosen the screws securing the electrical junction box cover to the water heater and set aside Louvered Panel 5 Connect the electrical supply to the water heater Astandard 1 2 inch opening has been made in the junction box for conduit connections Connect ground wire to green ground wire in the electrical junction box of the water heater Reinstall the junction box cover D and secure it using the screws loosened earlier Turn on electrical power to the water heater 0 Press the power button to turn the water heater on then press the Efficiency button to set the operating mode NOTE The water heater will conduct a system diagnostic approximately 8 minutes prior to returning to operation 11 Once the diagnostic sequence has finished the fan should turn on NOT
31. nts making an insulation blanket unnecessary 11 INSTALLATION CHECKLIST Water Heater Location Centrally located with the water piping system The flooring beneath the water heater must be able to support the weight of the water heater when filled with water See Table 1 Located indoors such as a basement or garage and in a vertical position Sheltered from freezing temperatures Provisions made to shelter the area from water damage Metal drain pan installed and piped to an adequate drain Sufficient room to service the water heater The water heater must have unrestricted airflow and requires a minimum installation space of 750 cubic feet As an example a room that has an eight foot tall ceiling and is 10 feet long by 9 1 2 feet wide would contain 760 cubic feet See The Confined Space Installation section of this manual for installing the water heater in spaces of less than 750 cubic feet NOTE This Heat Pump Water Heater may be located within a required minimum of 6 clearance from a wall on the inlet or outlet side however for future service considerations a minimum clearance of 3 feet from any obstruction on the left and right side air inlet and outlet is recommended The unit cannot be placed into any type of closet or small enclosure The site location must be free from any corrosive elements in the atmosphere
32. over the elements from their attachment point Disconnect the electrical wires from the heating element s by loosening the screws Figure 13 Remove the screw in element s by turning the element s counterclockwise with a 1 1 2 inch socket wrench Remove the existing gasket s Clean the area where the gasket s fits to the tank and internal threads If you are replacing the bottom element remove any accumulated sediment on the bottom of the tank Make sure the replacement element s has the correct voltage and wattage rating by matching it to the rating plate on the water heater Position the new gasket s on the element and insert it into the water heater tank Figure 14 NOTE Apply a light coat of hand dishwashing soap and water to the gasket Tighten the element by turning it clockwise until secure Close the drain valve and open the nearest hot water faucet Then open the cold water shut off valve and allow the tank to fill completely with water To purge the lines of any excess air and sediment keep the hot water faucet open for 3 minutes after a constant flow of water is obtained Screw in Element Check for leaks around the element s Reconnect the electrical wires to the element and securely tighten the screws See Figure 13 Replace the protective plastic cover s removed earlier Make sure the cover s are securely engaged on the attachment point s Replace the foam block s and access cover s Although
33. ow the safety alert symbol and either the word DANGER or WARNING These words mean You can be killed or seriously injured if you don t A DA N G E R immediately follow instructions A WAR N l N G heen ander seriously injured if you don t All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Important Safety Instructions CAUTION Hydrogen gas is produced in a hot water system served by this heater that has not been used for a long period of time 2 weeks or more Hydrogen gas is extremely flammable To reduce the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system When hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow There should be no smoking or open flame near the faucet at the time it is open The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer birth defects or other reproductive harm and requires businesses to warn of potential exposure to such substances WARNING This product contains a chemical known to the State of California to cause cancer
34. pacity 80 Gallon 80 Gallon IMPORTANT The water heater should be located in an area where leakage of the tank connections condensate lines or condensate will not result in damage to the area adjacent to the water heater or to lower floors of the structure Due to the normal corrosive action of the water the tank will eventually leak after an extended period of time Also any external plumbing leak including those from improper installation may cause early failure of the tank due to corrosion if not repaired If the homeowner is uncomfortable with making the repair a qualified person should be contacted Asuitable metal drain pan should be installed under the water heater as shown below to help protect the property from damage which may occur from condensate formation or leaks in the piping connections or tank The pan must limit the water level to a maximum depth of 2 1 2 inches and be two inches wider than the heater and piped to an adequate drain Locate the water heater near a suitable indoor drain Outside drains are subject to freezing temperatures which can obstruct the drain line The piping should be at least 3 4 ID and sloped for proper drainage Under no circumstance will the manufacturer or seller of this water heater be held liable for any water damage which is caused by your failure to follow these instructions Figure 2 Metal Drain Pan Installation PIPED TO AN ADEQUATE DRAIN AT LEAST 2 GR
35. r automobiles are located must never be ducted to any other space inside the building structure This would include all occupied and unoccupied spaces such as attics or basements Potentially harmful fumes and vapors could be introduced into living spaces 12 A duct termination or grill is required at the end of the duct run but not supplied with the Outlet Duct Kit Suitable duct terminations and grills are readily available from home centers or HVAC supplies Terminations must be fitted with screens or designed to prevent rodents other pests and debris from entering the ductwork If terminated outdoors or to another space where water or moisture may enter the ductwork terminations designed to prevent water or moisture infiltration must be used 13 If outlet ductwork is terminated through a ceiling into an attic space provision must be made to ensure the ductwork terminates well above the insulation line in the attic to prevent insulation from entering the ductwork A short section of 8 inch round metal duct may be used with a suitable duct termination Overall duct length including flexible and metal duct must not exceed 10 feet 14 Ductwork that transitions through walls or ceilings must be properly sealed to prevent rodent other pests or moisture infiltration Water System Piping Piping fittings and valves should be installed according to the installation drawing Figure 5 If the indoor installation area is subject
36. r certified as required by the authority having jurisdiction to perform a given task do not attempt installation Contact a local HVAC contractor to perform the installation Installation must comply with all national state and local building codes and agencies having jurisdiction Check with your local building code authority if you have any questions regarding code compliance 1 10 Inlet air is derived through louvered grill s installed in a door or wall between the installation space and another space inside the building structure The space from where inlet air is derived must be a minimum of 750 cubic feet See Figure 4 Installation is permitted in confined spaces between 750 and 610 cubic feet of space using one louvered grill or in spaces between 610 and 460 cubic feet using two louvered grills See Figure 4 and Table 2 For installation in confined spaces of less than 460 cubic feet the accessory Outlet Duct Kit PN 9910006000 is required With this kit installation is permitted in confined spaces between 460 and 400 cubic feet with one louvered grill or in spaces between 400 and 128 cubic feet with two louvered grills See Figure 4 and Table 2 Minimum louvered grill size is 16 x 24 for each grill installed Fully louvered doors are an acceptable substitute for louvered grill s if the louvered area of the door is not less than the total required area the grill s would provide Follow the instructions included
37. rain or condensate pump See Figure 4 Electrical Connections This water heater requires a 240 VAC single phase 25 amp power supply DO NOT use a 208 VAC service Wiring size and connections comply with all applicable codes or in the absence of local or state codes follow NFPA 70 the National Electrical Code current edition Water heater and electrical supply are properly grounded Wiring enclosed in approved conduit if required by local codes Proper overload fuse or circuit breaker protection installed Post Installation Review Understand how to use the User Interface Module to set the various modes and functions See Adjusting the User Interface Module Operating Modes section Hybrid Mode is the recommended Operating Mode Understand the various Operating Modes and which mode may be best based on season ambient temperature and usage See Operating Mode Description section NOTE It may be necessary to temporarily change modes if for example filling a spa or hot tub Understand the importance of routine inspection maintenance of the condensate drain pan and lines See Inspection Cleaning of the Condensate Drain Pan amp Condensate Drain Lines section This is to help prevent any possible drain line blockage resulting in the condensate drain pan overflowing IMPORTANT Water coming from the plastic shroud is an indicator that both condensation drain lines may be blocked Immediate action is req
38. re is a hot water scald potential if the temperature set point is set too high IMPORTANT Adjusting the set point above 120 F on the User Interface Module will increase the risk of scald injury in the times shown below Table 3 Time for Permanent Burns 2nd amp 3rd Degree Most Severe Bums Time for 1st Degree Burn Less Severe Bums Water Temperature F 110 116 116 122 131 140 normal shower temp pain threshold 35 minutes 1 minute 5 seconds 2 seconds 45 minutes 5 minutes 25 seconds 5 seconds 149 1 second 2 seconds 154 instantaneous 1 seconds U S Government Memorandum C P S C Peter L Armstrong Sept 15 1978 NOTE During low demand periods when hot water is not being used a lower temperature set point will reduce energy losses and may satisfy your normal hot water needs If hot water use is expected to be more than normal a higher temperature set point may be required to meet the increased demand When leaving your home for extended periods vacations etc set the water heater to Vacation Mode See Adjusting the User Interface Module Operational Modes section This will maintain the water at low temperatures with minimum energy losses and prevent the tank from freezing during cold weather NOTE When returning from an extended stay remember to set the water heater back to the desired Operational Mode 13 Adjusting the User Interface Module Operational Modes Water Temperature Adj
39. such as sulfur fluorine and chlorine These elements are found in aerosol sprays detergents bleaches cleaning solvents air fresheners paint and varnish removers refrigerants and many other commercial and household products In addition excessive dust and lint may affect the operation of the unit and require more frequent cleaning See Cleaning the Heat Pump section Ambient air temperature must be above 45 F and below 109 F If the ambient air temperature falls outside these upper and lower limits the electrical elements will activate to meet the hot water demand Water System Piping 12 Temperature and pressure relief valve properly installed with a discharge pipe run to an adequate drain and sheltered from freezing See Figure 5 All piping properly installed and free of leaks Heater completely filled with water See Water Piping System section Closed system pressure buildup precautions installed See Closed System Thermal Expansion section Mixing valve when applicable installed per manufacturer s instructions See Water Temperature Regulation section Condensate Drain Line Installation Must be located with access to an adequate drain or condensate pump Condensate drain lines installed and piped to an adequate d
40. ted Water connections to unit reversed Heat lost thru long run of exposed pipe Hot water leak at faucet or piping Sediment or scale build up in tank Excessive water pressure Add or service a thermal expansion tank Non functioning Temperature amp Pressure Relief Valve The water heater does not immediately start The heat pump does not run in Efficiency mode Check for blown fuse or tripped breaker Restore power to unit then press power button Press the power button to turn the unit on power button GREEN Press Vacation Mode Button to exit Vacation mode and return to desired operating mode Reset the high temperature limit switch see Safety shut off section for more information Change to different mode or modify usage patterns Contact a qualified person for service Increase set point temperature see Adjusting the User Interface Module section Clean air filter Change to different mode or modify usage patterns For example if in Efficiency Mode switch to Hybrid Mode Ensure the cold connection is at the bottom and that the hot connection is at the top Insulate exposed piping Repair hot water leaks Call qualified person for service Drain and flush tank Water conditioning may be necessary to minimize build up Decrease set point temperature see Adjusting the User Interface Module Clean air filter Change to Efficiency or Hybrid mode for re duced energy costs Ensure the cold conne
41. to freezing temperatures the water piping must be properly insulated Water supply pressure should be 50 60 PSIG and not exceed the maximum 80 PSIG If the supply line pressure exceeds 80 PSIG a pressure reducing valve PRV with a bypass should be installed in the cold water supply line This should be placed on the supply to the entire house in order to maintain equal hot and cold water pressures IMPORTANT Heat must not be applied to the water fittings on the heater as they may contain nonmetallic parts If solder connections are used solder the pipe to the adapter before attaching the adapter to the hot and cold water fittings e Always use a good grade of joint compound and be certain that all fittings are tight IMPORTANT DO NOT over apply joint compound Piping Installation 1 Install the water piping and fittings as shown in Figure 4 Connect the cold water supply 3 4 NPT to the fitting marked Cold Connect the hot water supply 3 4 NPT to the fitting marked Hot 2 The installation of unions in both the hot and cold water supply lines are recommended for ease of removing the water heater for service or replacement Temperature and Pressure Relief Valve Discharge Pipe Do Not Cap or Plug _ gt Metal Drain Pan 2 1 2 Depth Maximum and 2 Inches wider than the water heater Optional Heat Trap Piping Shut off Valve Hot Manu
42. uired To maintain optimal operation check remove and clean the air filter See Air Filter Cleaning Replacement section The Installation Instructions and Use amp Care Guide should be kept with the water heater for reference OPERATING YOUR WATER HEATER Before Using 1 Make sure the water heater has been properly installed See Installing Your Water Heater section 2 Make sure the air filter is correctly seated as it may shift during shipping or installation See Repair Parts Illustration section 3 Completely fill the tank with water See Water Piping section 4 After the water heater tank is completely filled with water connect electrical power to the water heater 5 Read the Water Temperature Regulation section of this manual If you do not fully understand these instruction contact a qualified person 6 Press the power button See Figure 11 to turn the water heater on and allow it to run a system diagnostic This typically takes eight minutes Once complete proceed to the next step NOTE If the system diagnostic yields any codes reference the Diagnostic Code section in this manual 7 Adjust the thermostat to the desired temperature setting as described under Adjusting the User Interface Module Operational Modes section IMPORTANT Do not attempt to operate this water heater if the unit has been submerged subjected to flooding or surrounding insulation has been exposed
43. urations are possible when using the Outlet Duct Kit PN 9910006000 and or the Inlet Duct Kit PN 9910005000 with these water heaters Consult the installation instructions included with the duct kits for additional information These instructions are also available on the manufacturer s web site Contact the distributor where the water heater was purchased for information on ordering these duct kits AIR FLOW 1 1 EXTEND DUCT I ABOVE INSULATION IN ATTIC SPACES ba a a ae OOII ZS BOOT COLLAR LLL te ea 7 DUCT a CONFINED once te fs 8 INCH E SPACE Hal peee V AIRFLOW 4 L su DUCT j in 7 BM y Sd lt lt gt Ry SY AIR FLOW paan XZ RG Oo egies Be 2 lt Pars oa DUCT eet eee KIT ADAPTER MINIMUM i 16 X 24 ry prea ara EN AIR FLOW Be SSH 777 LLLELILLMAPELLLELLLALEEPLILELLLLLLEDLLE ELLE AME EL LE FIGURE 4 Table 2 WITHOUT DUCTWORK WITH 8 INCH FLEXIBLE DUCT AND OUTLET DUCT KIT LOUVERED GRILL CONFINED SPACE CONFIGURATION door or wall MINIMUM SPACE 460 400 128 cubic feet EXAMPLE ROOMSKE 8 x7 6 x10 8 x5 75 x10 8 x10 x5 8 x4 x4 HX L X W feet Installation Installation requires ability equivalent to that of a qualified HVAC installer Installation skills such as air supply venting and duct installation are required If you are not qualified and licensed o
44. ustment The water temperature can be adjusted from 95 F to 150 F Use the Up and Down Buttons _A v_ on the front panel to set the desired temperature IMPORTANT Before attempting to adjust the thermostat read the Water Temperature Regulation section If the instructions are not clear contact a qualified person IMPORTANT Filling a spa or hot tub from this water heater may result in extended recovery re heat time Switching temporarily to Hybrid Mode or Electric Mode will decrease the recovery re heat time Be sure to switch back to the desired operational mode when finished Operating Mode Descriptions The operating modes can be changed by touching the desired mode icon on the User Interface Module see Figure 11 NOTE All buttons on the User Interface are touch sensitive and require only a light touch to actuate Hybrid Mode This is the default recommended setting Combining high energy efficiency with reduced recovery time This mode uses the heat pump as the primary heating source The heating element will heat water if demand exceeds a predetermined level so that the set point temperature can be recovered more quickly Efficiency Mode Is the most energy efficient mode This mode uses the heat pump to heat water in the tank The elements are not used unless the ambient operating temperature is below 45 F or above 109 F If hot water demands are not met in Efficiency Mode it may
45. with the Outlet Duct Kit for the included duct adapter and ductwork Eight 8 inch flexible ducting is required but not supplied in the Outlet Duct Kit Suitable ducting is readily available at home centers or HVAC supplies Duct collars and boots may also be required but are not supplied with the Outlet Duct Kit Suitable collars and boots are readily available from home centers or HVAC supplies The maximum length of duct allowed is 10 feet This maximum length must not be exceeded under any circumstances Ducting should be installed as straightly as possible there must be no kinks or flattening of the ductwork The Outlet Duct Kit and connected ductwork must redirect outlet air from the unit to a location other than the confined installation space The alternate location to where the outlet air is redirected must be a minimum of 750 cubic feet AWARNING Breathing Hazard Carbon Monoxide Gas e Do not duct air from a garage or other space where potentially harmful fumes from solvents chemicals or exhaust from automobiles are present into any other space in the building structure e Gas and carbon monoxide detectors are available Breathing carbon monoxide can cause brain damage or death Always read and understand instruction manual 11 The outlet air from a unit installed in a garage or drawing inlet air ffom a garage or any area where solvents or other chemicals that emit potentially harmful fumes are stored o
46. x to the condensate pump and cut two 18 AWG or larger wires to correct length and strip the insulation at both ends of each wire See Figure 9B 5 Connect these two wires to the two wires on the water heater using wire nuts or other connectors 6 Connect the free ends of the two wires to the shut off switch on the condensate pump in accordance with the manufacturers recommendations Turn on electrical power to the water heater Press the power button to turn the water heater on and select the desired operational mode After about 8 minutes the heat pump will turn on 9 Test the operation of the shut off switch by unplugging the condensate pump and filling the condensate reservoir with water until the float switch opens the circuit 10 The heat pump should turn off and the error code CONDENSATE DRAIN ALARM will appear on the user interface screen 11 Plug the condensate pump in and verify that the pump operates and pumps the water out of the condensate reservoir 12 The error on the user interface should clear and the heat pump should operate after 8 minutes Insulation Blankets The use of an insulation blanket on this water heater is not needed or recommended The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters Your water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requireme