1. F is fed with the control voltage which in turn controls the primary swing The stepped up R F output is fed to a voltage doubler and HV filter A fraction of this output through a bleeder is taken and compared at the op amp input with a standard reference voltage applied through a ten turn pot The output of this op amp inturn generates corrective control voltage through a regulator chip for EHT regulation BLOCK DIAGRAM of HIGH VOLTAGE HV501 HV OUTPUT 555 OSC PUSH eet 4 RF TRANS Zi VOLTAGE fa HV 15 KHz DRIVER FORMER DOUBLER FILTER CONTROL VOLTAGE TEN TURN POT VOLTAGE REGULATOR D P M D i S p l a y 6 1 6 2 a CHAPTER VI AVAILING OF MAINTENANCE CALIBRATION SERVICES AND WARRANTY CLAUSE with in India GENERAL As per the warranty clause of the company we provide one year warranty during which period we provide free service at our works Hence in case of any mal function in our instruments you are requested to send the unit back to our works by RPP COURIER SPEED POST PARCEL GATI XPS door delivery We shall arrange immediate rectification replacement within two weeks from the date of receipt of the equipment at our place Please note that the equipment will be serviced at our works only The equipment is to be sent to The Servicing Department NUCLEONIX SYSTEMS PRIVATE LIMITED Plot No 162 A amp B PHASE Il D A Cherlapally Hyderabad 500 051Ph 040 27263701 329145448 32918055 E
2. has the following policy to provide maintenance support to overseas customers either directly or through international dealers distributors During amp after warranty For minor problems which can be handled by customers servicing tips have been provided in the user manual servicing manual Also most of the equipments have built in fault diagnostic features which will indicate to the user nature of problem in the equipment Based on the visual indication in the instrument Display user can take corrective action or contact Nucleonix systems by email for help Nucleonix systems will guide in localizing the defective part module or sub system by interacting with the customer if required Skype will be used for communication During warranty free replacement of sub system or board PCB will be done However customer has to send defective sub system back to Nucleonix system with in 15 days on arranging replacement During amp after warranty any Freight charges amp customs clearance charges are to be borne by customers both ways If it is a manufacturing defect then Nucleonix system will bear the replacement cost of sub system unit However any Freight charges amp customs clearance charges in their country are to be borne by customer After warranty services will be similar to that of services during warranty However customer will have to pay for cost of parts replaced freight charges both ways amp customs clearance charges i
3. of the PC vendor is to be contacted Also for software related problems online support will be provided Software support doesn t include cleaning of virus problems etc When the equipments are sent to our works for warrantee services they are to be properly packed with adequate cushion to prevent any transportation damages Nucleonix Systems is not responsible for damages or loss during transportation Packing Freight charge is to be borne by customer when he sends the equipment to our works However when we return after servicing packing will be Nucleonix responsibility amp Freight charges will be to your account Only services are free Please indicate in your correspondence equipment model amp serial number All the equipments are to be sent to our works only on door delivery basis e For Door Delivery Transportation contact XPS GATI cargo in your city town or a reliable courier service to pick the consignment from your place For their nearest local address amp phone no s look into their websites Transit insurance if the customer feels is necessary it is to be covered Nucleonix Systems will not receive the equipments sent by other modes of transportation such as Rail Road After servicing equipments will be sent back by same mode of transport such as XPS GATI COURIER RPP b 6 3 a All types of Radiation detectors glass ware PMTs etc which are fragile are not covered in warrantee if the failure
4. proposal e Name year amp data of purchase SI Nos of equipments Model No s No of equipments for which AMC is required Additionally no of calls per annum required for preventive amp breakdown maintenance may also be indicated Advantage of entering into AMC Equipment services offered will be prompt amp timely e Nucleonix systems maintain required spares spare tested PCBs detectors amp other critical components which may become obsolete Obsolescence in electrons is quite rapid If you enter into AMC guaranteed service for the period of AMC will be the responsibility of Nucleonix Systems e Nucleonix Systems will maintain Engineers at your disposal to attend to AMC calls on time e Without AMC prompt service calls are not guaranteed e If some critical components become obsolete then Nucleonix systems may request you to upgrade the product with new model or new electronics which may be expensive if you are not under AMC Training on maintenance servicing To a limited extent we offer training on maintenance repairs at our works to customers on chargeable basis Details can be obtained from our customer support division by customers who may require such services
5. Calibration Lab This has a Cs 137 165 mci standard Gamma Survey Instruments Calibrator from Amersham This calibration service has NIST Traceability standard Calibration of all portable radiation monitors survey meters contamination monitors Area monitors etc is carried out in this lab upto 1 R hr max dose rates Gamma Survey instruments calibrator has Cs 137 source 161 5 mCi as on 05 Aug 2002 It is basically a gamma survey instruments calibrator procured from AEA Technologies UK USA Has NIST traceability accuracy within 7 6 5 Gamma Survey instruments calibrator has Cs 137 source 161 5 mCi as on 05 Aug 2002 It is basically a gamma survey instruments calibrator procured from AEA Technologies UK USA Has NIST traceability accuracy within 7 Fe ONS ae CRC 2 camera has Co 60 standard obtained from Bhabha Atomic Research Centre Mumbai It is a certified source ANNUAL MAINTENANCE CONTRACT AMC Annual maintenance contract AMC services For all sophisticated instruments amp systems and also for installed monitors amp networked systems in a nuclear facility or a Radiological lab or in a Medical cyclotron facility where no of instruments are networked itis advised that customer enters into an economical Annual maintenance contract with Nucleonix system Detailed AMC proposal can be obtained from our customer support division CSD by giving required inputs Inputs required by our CSD to send you AMC
6. INSTRUCTION MANUAL HIGH VOLTAGE UNIT TYPE HV501 NUCLEONIX SYSTEMS PRIVATE LIMITED Plot No 162A amp B PHASE Il D A Cherlapally Hyderabad 500 051 Ph 91 040 27263701 30918055 FAX 27262146 e mail info nucleonix com www nucleonix com FileName HV501_MAN Date 20 08 2012 SI No CHAPTER CHAPTER II CHAPTER III CHAPTER IV CHAPTER V CHAPTER VI CONTENTS Description Unpacking Introduction Specifications Installation Operating Instructions Block diagram amp Description Availing of Mainstenance Calibration Services and Warranty Clause IMPORTANT NOTES POLARITY REVERSAL If the unit is in operation with a particular POLARITY reduce the EHT to minimum and switch off the EHT ON switch Open the right side cover Open the screw on right side to open side cover and slide it out Notice a small connector POLARITY connector which is to be pulled out and plugged in again in the reverse way Close the side cover and now the unit is ready for operation with POLARITY being reversed UNPACKING The High Voltage Unit Type HV501 has been thoroughly tested and is despatched in ready to operate condition However on unpacking and prior to operation it is advisable to check visually and make sure that there is no visible damage caused in transist If any damage to the instrument be observed do not switch ON the unit and report the matter immediately to Customer Su
7. T socket Switch ON the bin and the ON switch of HV501 to generate EHT and set the knob to obtain the required EHT setting BLOCK DIAGRAM DESCRIPTION This High Voltage Circuit employed in this design essentially consists of an external driver oscillator 555 chip This generates square wave oscilations in the range of 25 to 35KHz 12V supply from the bin is provided to this oscillator This output is phase split and fed to the differential driver Power Amplifier consisting of two power transistors fed to the primary of the R F transformer The center tap of this R F is fed with the control voltage which in turn controls the primary swing The stepped up R F output is fed to a voltage doubler and HV filter A fraction of this output through a bleeder is taken and compared at the op amp input with a standard reference voltage applied through a ten turn pot The output of this op amp inturn generates corrective control voltage through a regulator chip for EHT regulation CHAPTER V BLOCK DIAGRAM DESCRIPTION This High Voltage Circuit employed in this design essentially consists of an external driver oscillator 555 chip This generates square wave oscilations in the range of 25 to 35KHz 12V supply from the bin is provided to this oscillator This output is phase split and fed to the differential driver Power Amplifier consisting of two power transistors fed to the primary of the R F transformer The center tap of this R
8. UHF Socket by default MHV Socket if specified It can deliver upto a maximum of 1mA The unit is offered with a choice of both POSITIVE or NEGATIVE POLARITY selectable by reversing a polarity connector Provided inside Better than 0 005 of full scale Less than 20 mV peak to peak Indefinite protection against overload and short circuit Under overload the unit doesn t meet the specifications whereas on removal of short circuit it will recover by itself Draws power from a standard BIN NIM Power Supply or MINIBIN power supply 24V at 250mMA 12V at 50mA 12V at 50mA Better than 0 2 Better than 100 PPM Better temperature stability can be offered at extra cost Standard 2 bit Amphenol connector Type 26 159 24P H 24 pin type or NIM standard connector as per AEC specifications TID 20893 Rev Type AMP 2041865 optional CHAPTER Ill INSTALLATION The High Voltage Unit Type HV 501 is a standard HV unit two bit offered in modular form It is highly stable well regulated with low ripple noise and serves as a detector bias unit for various nuclear detectors It is specially designed to be as constituent part of MINIM Gamma Ray Spectrometer and is used for biasing a Scintillation detector A INSERTING THE MODULE INTO THE BIN The Bin is fitted with guides SS rods at the top and bottom to help guide and position the modules To insert the module into the Bin the projected edges at the top and bott
9. ed to ensure good packing to avoid any transportation damages Especially if there are external detector probes they are to be packed with sufficient soft foam to ensure no damage in transportation 5 Use only the specified following mode of transportation system for dispatching on door delivery basis XPS GATI cargo Courier RPP Speed Post parcel etc Send the equipment on freight paid basis Equipments sent by other methods such as Rail Road etc will not be collected Also you can cover for transit insurance both ways if you wish Nucleonix system is not responsible for any transportation damages or loss during transportation both ways 6 Immediately on receipt of the equipment we will send an acknowledgement amp also a proforma bill by email post 7 Based on the proforma bill once we receive the payment equipment will be dispatched back by similar mode of transportation as mentioned above HOW TO AVAIL CALIBRATION SERVICES FOR FOREIGN CUSTOMERS Foreign customers can calibrate Nucleonix make Radiation monitors equipments in their country at any of their accredited Radiation calibration labs Nucleonix systems will be happy to provide any help and guidance if needed for calibration Alternatively if you send the equipment here to India we can also provide calibration services Calibration Standards Lab amp Facility We have two calibration labs i Low Level Calibration Lab ii High Dose Rate Calibration lab Low Level
10. is due to physical damage external or internal due to shock dropping miss handling etc If the failure is due to a natural fault then only it is covered under warrantee for a limited period of three months However complete electronics is covered for 1 year warrantee You can also send the equipment personally to our works for repairs either during or after warrantee after fixing up with our service dept Customer Support Division If possible we may repair on same day or your person can stay for a day or two amp get it repaired amp or calibrated After warrantee Services On expiry of 1yr warrantee if you like to send the equipment low cost less than 6 0 lakhs for repairs to our works you may please observe the following procedure Send an e mail with details mentioning that you agree to pay service charges which includes Basic service charges per unit module in the range of Rs 2500 to Rs 10 000 depending on the sophistication of the unit calibration charges if applicable for your equipment cost of components packing charges Return Freight charges actual Once our customer support department responds amp requests you to despatch the equipment to our works for repairs you may do so by following the steps given below Followed by this you can send the equipment straight away if it is within 5 yrs old If the equipment is beyond 5 yrs old then also you can send it for repairs however only after you receive confirmation f
11. mail info nucleonix com www nucleonix com For all the Radiation monitoring equipment detectors built in or external probes will not have one year warranty but only inspection warranty at the time of supply is provided Since detectors will may have fragile glass construction we do not provide warranty In case of failure of these components Nucleonix will supply detector replacement at cost cost price Note In respect of all types of portable radiation monitors it may be necessary to checkup and recalibrate the equipment once a year at our works EQUIPMENT REPAIRS SERVICING POLICY WITH IN INDIA During Warrantee The following procedure is to be followed by the customers with in India for availing services repairing facility during warrantee period e Equipments are to be sent to our works for availing free repair services during warrantee after the customer receives approval from the customer support division by sending an e mail For all equipments costing less than 6 0 lakhs one year warrantee amp free service is offered when the equipments are sent to our works only For larger systems such as installed systems networked systems specialized systems costing more than 6 0 lakhs during one year warrantee free service is offered at site Field service Engineer will be deputed subject to warrantee terms amp conditions This does not include personal computer related problems for which local computer service provider
12. n both the countries Nucleonix systems plans to introduce audio visuals on web or on CDs to facilitate product demonstration installation amp minor maintenance very soon 6 4 6 5 HOW TO AVAIL CALIBRATION SERVICES FOR INDIAN CUSTOMERS Nucleonix Systems offers radiation calibration services to its customers Calibration services are provided for Nucleonix Systems manufactured products only in general as a company policy How to avail calibration services Itis best advised that each of the Radiation monitors including Area monitors are calibrated once in a year When you want to send your Radiation monitor Area monitor Contamination monitor for calibration to our works You may send the equipment for calibration by following the steps given below 1 Our standard calibration charges per equipment All types of Radiation monitors including portable survey meters contamination monitors amp Area Gamma Monitors are Rs 2500 Packing Freight charges You can email a work order accepting these charges 2 Email your work order and despatch send the equipment to our works if it is 5 years old or less including details of mode of transport sent with docket particulars 3 Also mention in your work order amp clearly indicate that you will agree to pay calibration charges amp also equipment repair charges additionally if the unit is faulty amp requires repairs before one can take it up for calibration 4 You are request
13. om right hand side of the module should be positioned into the S S rod channel grooves and pushed right in until the 24 pin 42 pin power connectors of the bin and module are fully engaged The captive screws on the module should then be tightened B POWER TO WORK THE MODULE The input power to work the module is fed through the connector at the rear side of the module This connector mates with one of the output connector sockets of MB403 when the module is slid into the bin CHAPTER IV OPERATING INSTRUCTIONS OPERATIONAL CONTROLS ON SWITCH This is a toggle switch which facilitates one either to choose the EHT or disable the EHT when not required EHT OUTPUT This is an amphenol UHF socket Type 83 798 H or MHV SHV connector optional from where one can draw the EHT output to the required load EHT ADJUST The EHT output can be adjusted by this knob This knob is fitted on to the shaft of a ten turn helipot HOW TO OPERATE THE UNIT Insert the HV501 module into the bin as explained under INSTALLATION Switch ON the bin and HV501 module to generate EHT and set the knob to obtain the required EHT With a proper multimeter High impedance check the EHT OUT and ensure that EHT OUT is proper and disconnect the multimeter In a typical Gamma Ray Spectrometer system Connect one end of the EHT cable cable with two end UHF MHV male connector to the EHT OUTPUT socket and the other end to scintillation head EH
14. pport Division Nucleonix Systems Private Limited Plot No 162A amp B PHASE II D A Cherlapally Hyderabad 500 051 Ph 91 040 27263701 32918055 FAX 27262146 e mail info nucleonix com www nucleonix com In all correspondance regarding the instrument please mention the serial numbers of the unit month and year of purchase of the unit CHAPTER INTRODUCTION NUCLEONIX offers a standard High Voltage Unit Type HV501 which is a compact STANDARD NIM Module 2bit This is designed to meet the full HV bias requirement for a broad range of Nuclear radiation detectors like G M detectors ionization chambers scintillation detectors photo multiplier tubes etc Apart from this range of applications it also can be used as a high voltage source in areas where high degree of regulation stability and accuracy are required Output can be varied by a precise ten turn helipot and output indication is provided on a DPM FRONT VIEW REAR VIEW EHT b HIGH VOLTAGE UNIT ety mat OUTPUT VOLTAGE OUTPUT INDICATION OUTPUT CONNECTOR OUTPUT CURRENT OUTPUT POLARITY LINE amp LOAD REGULATION RIPPLE PROTECTIONS POWER REQUIREMENT LINEARITY TEMPERATURE STABILITY MECHANICAL DIMENSIONS REAR MODULE CONNECTOR CHAPTER Il SPECIFICATIONS OV to 1500V continuously variable by a ten turn helipot provided on front panel All specifications are valid from 10V to 1500V Provided on a 3 1 2 digit LED DPM
15. rom Customer Support Division that it is repairable amp is not an obsolete model If the design is obsolete then customer support division CSD may give you buy back offer to replace with new model or upgrade it with electronic circuit boards amp enclosure For all installed equipments costing above Rs 6 0 lakhs which are larger in size amp for which field servicing only is recommended you can obtain a quotation with relevant details by sending an e mail amp avail the services accordingly For all field servicing jobs since we need to depute engineers it is likely to take time amp also it will cost more which includes Engineer s TA amp DA etc apart from basic service charges cost of spares etc Please note that basic service charges will be different for different products depending upon sophistication Also in some cases it may not be possible to fix up the problems in the field itself in such cases we may advise you to send them to our works For all jobs to be serviced in the field customer is requested to provide adequate details on the nature of problems to enable our engineer to come prepared with adequate spares For any additional information send an e mail to info nucleonix com Atten Customer support division EQUIPMENT REPAIRS SERVICING POLICY FOR EXPORTS Equipments manufactured amp exported are subjected to a well defined quality assurance QA plan amp Factory acceptance tests FAT Nucleonix systems
Download Pdf Manuals
Related Search
Related Contents
Best Data Radeon HD 5570 ATI Radeon HD5570 1GB avant toute utilisation 一太郎 11/10/9/8 文書 【Mate J】総合カタログ(2005/05) Manuale utente telecamera UVC-XP4DN- HR(-P) Bedienungsanleitung ZA 27 ZB 27 - WAGNER® 取扱説明書 - 日立の家電品 Lindy 4-Port DVI 6bxc user`s manual EH-TW9200W - Epson Europe Copyright © All rights reserved.