Home
S900 Serial - sentinelguardbulgaria.com
Contents
1. he short message and multimedium message 78014 Arming 01 Password BF Password Master and family m Instruction Detail is see 4 Quick start 4 arming The guest have 02 CF no right Disarming 02 Password Password Instruction Detail is see 4 Quick start 5 disarming Short message command Figure phonetic User Function Figure Phonetic 05 description description Master Add or delete the sensor EET Instruction Detail is see 5 Advanced operation ee iae 8 Wireless sensor 112 SCCGQ B Delete all of the sensors Delete the remote controller 111 SCCKQ 03 Pieces P Z Pieces PZ Password Ask for the photo take a 03 Password Pieces Pieces picture Instruction Detail is see 4 Quick start 6 Ask for the photo The default setting is 1 03 Pieces 1 PZ Pieces Y X PZ Password Ask for the photo to the 03 Password Pieces 1 Pieces Y X4 mailbox take a picture Master family Instruction The mailbox address must setting in advance and guest see detail 5 advanced operation 12 mailbox 07 Inquiry status 07 Password CX Password Instruction Detail is see 4 Quick start 8 Inquiry status Ask for common co
2. User Function Figure Phonetic 00 Master Start on this product Instruction Detail is see 4 Quick start 2 Start the product 04 old password MM old password New password New password Modify the password Instruction Detail is see 4 Quick start 3 Modify password 144 Family s phone XGZR Family s phone Modify the Master s No No password Instruction Detail is see 5 Advanced operation 2 modify the Master s phone No 06 Family s phone No ZJJR Family s phone Add the family s mobile No phone No Instruction Detail is see 5 Advanced operation 3 Add Master The and delete the family s phone No famil t amily and gues 113 Family s phone SCJR Family s phone h ight iac Delete the family s mobile No No phone No Instruction If you are not add the specify phone No in the command that s means delete all the phone No 106 Phone No ZJJJ Phone No Add the emergency phone N Instruction Detail is see 5 Advanced operation 4 Add and delete emergency phone No 107 SCIJ Delete all of the emergency Instruction Delete all of emergency phone No phone No only save the Master s phone No Emergency key s alarm 39 Value JJBJ Value mode Instruction Value is 0 call the phone Value is 1 sentt 233
3. emergency phone No is full If you repeat setting same phone No The product will reply to you XX XXXX No is already existed Delete 107 SCJJ When you success to setting the product will reply to you Success to delete the emergency phone No Adding the emergency phone No is one by one but delete the emergency No is delete all only keep the Master s phone No Note Emergency phone No can be the mobile phone telephone or handphone If it s the long distance No you must add the area code before the phone No The telephone and the handphone can t receive the multimedia message at present need the network support It s only can use the phone to monitor The Master can setting call the phone or send the short message multimedia message two emergency keys to alarm Setting the emergency alarm mode Use the Master s phone to send any short message as below to the product 2394 Value JJBJ Value When the Value is 0 it s will call the phone to the Master No and the emergency No in sequence If the Master phone has no answer It s will call to the emergency phone No in sequence until get through All the phone No only call one time and not repeat dial When you get through you ll hear the alarm spot voice When the value is 1 it s send the short message and the multimedia message to the Master phone No The default setting is 0 After the success setting the product will according to
4. After start up the product when you press the arming key if you are not hear the DI voice you must re learn the binding the usage method is as below After the start on press the mainframe back s setting key to enter to the learning status The indicator lamp is change to orange slow blink Press any key of the remote controller the remote controller indicator lamp is on When the product receive signal it s will emit the voice the green light constant on 1 second is means confirm and then change to the orange light slow blink now you can re learn the remote controller After 15 seconds it s will automatic exit to the learning status 4 Arming Directness to press the remote controller s arming key After you press the key you ll hear the voice and at the same time Master s mobile phone will receive a short message success to arming The indicator light is change to the green constant on 5 Disarming Directness to press the remote controller s disarming key After you press the key you ll hear the voice and at the same time Master s mobile phone will receive a short message success to disarming The indicator light is change to the green blink 10 6 Ask for the photograph Regardless of the product status is arming or disarming the Master and the family can ask for spot photograph from this product Ask for one photo each time Method 1 Use the Mast
5. FOR eerie re eet rete AE EEO tie een i ei 13 1 CHANGE 13 2 CHANGE THE MASTER S MOBILE PHONE 14 3 ADD OR DELETE THE FAMILY S MOBILE PHONE 14 4 ADD OR DELETE THE EMERGENCY PHONE 14 5 WIRELESS REMOTE CONTROLLER S OPERATION INSTRUCTION eese enne 15 Ge Uer ODE gras een V este 16 FERENT 16 8 WIRELESS SENSOR AE Re 17 9 AUTOMATIC ALARM MODE 10 MOTION DETECTION 11 SETTING THE PHOTO IMAGE 12 MAILBOX 1 Product characteristics 1 This product is use the SIM card which is support the multimedia message s GSM network it s can send the photos to the multimedia message mobile phone or to the mailbox Have the CMOS camera and the infrared lamp support the night infrared photograph Support the mobile phone message remote operation is private and safety Support the mobile phone to monitor the alarm voice Connect to the 15 pieces wireless alarm sensors and 8 pieces remote controllers Support to give the alarm by the short message and the multimedia message Equip the wireless remote control arming disarming or the emergency alarm Use the motion detection technology Alarm accurate NO 00 10 tn BW Complete wireless system The installati
6. open and close one time in order that this product will receive the magnetic contact s wireless signal Return to the spare time status when success to learning the sensor and reply sensor X learning success d If the sensor learning is un success or not have the sensor to learning after the red green alternative blink about 1 minute this product will automatic exit to the learning status and return to the arming or disarming status This product can external connection with the 15 pieces wireless sensor at most Modify the wireless sensor During the add wireless sensor s step 2 if your sending sensor description message is the same as the existing sensor this product will re learning the new sensor to replace the former sensor The other steps is the same as the add sensor Delete all of the wireless sensor Operation Master family The Master and the family s mobile phone send any short message as below to this product 41124 or SCCGQ After success delete this product will reply short message Success to delete the sensor 9 Automatic alarm mode This product can through the motion detection wireless sensor and press the remote controller s emergency key three methods to trigger alarm The former two mode is the automatic alarm Its default mode is send the short message and multimedium photos The Master and the family can send any short message as below to this product to setting the automatic alarm mode 1
7. other s privacy right If infringement due to this reasonjit s not relevant to our company Content 1 PRODUCT CHARACTERISTICS ee ee ee esee epo ee eese ease eese esee eso seen os esne esee ee seen se epos esses so sesosoe PRODUCT ACCESSORY 6 USER RIGHTS LEVE b Dre ee iere veia eti e Hoe e E eevee oud be 6 AUTOMATIC 7 IDIRIN TINE vede 8 ASK FOR THE PHOTOGRAPH we vin ie A ees 8 MONITOR ON THE SPOT i iie ere Pi 8 8 era Ee eget 8 REMOTE CONTROLLER 9 THE INDICATOR LAMP S STATUS 5 9 INSTALLATION 10 Ten TURN ON TURN ORE eiie reet E TRI TEUER EGRE E RERO E E TRA 11 2 THE PRODUCT 11 3 BINDING WITH THE WIRELESS REMOTE 11 A ARMING REE EES 11 EP BIRIN aV TIN LEES 12 6 FOR THE PHOTOGRAPH te 12 Te MONITOR THE E ETS 12 8 INQUIRY THE STATUS o menace gen thoes yere E E E E AEA EA 12 VASK
8. pixel 32 Value or Value ade Setting photo image s brightness Use the Master and the family s mobile phone send the short message as below to setting the image to 5 different brightness The value is 1 2 3 4 and 5 1 is Min brightness 5 is Max brightness The default setting value is 4 34 Value or TXLD Value Setting the photo image s direction This product s mainframe panel can overall rotation When you fixed the position you must send the short message as below to set the photo s direction When the value is 1 it s the mainframe headstand s photo means headstand the product to take a picture When the value is 2 it s the mainframe traverse s photo the mainframe s long side is face down When the value is 3 the product is normal lay on the horizontal plane to take a picture The default setting is 3 35 Value or TXFX Value Setting the photo image s contrast ratio Use the Master and family s mobile phone to send the short message as below to setting 5 different contrast ratios The value can be 1 2 3 4 and 5 Therefore the constrast ratio is crescendo from 1 to 5 The default value is 1 38 Value or TXDBD Value 12 Mailbox Operation Master family Master and the family can send a short message as below to add the mailbox delete mailbox and whether send to the mailbox or not etc setting When you success to setting send to the mailbox this product will send the s
9. the setting to reply Emergency alarm calling is success or Emergency alarm multimedium message is success Inquiry Details are see 10 Inquiry status 5 Wireless remote controller s operation instruction The wireless remote controller have 3 keys Arming key Emergency key Disarming key When you press the arming key the mainframe s indicator light is green constant on and now enter into the arming status If the wireless sensor is triggered or the image is moving on the spot all of these will trigger the mainframe to give alarm calling phone or sending the short message multimedium message When you press the_emergency key the indicator light is red quick blink The default alarm sequence is calling the Master and the emergency phone No If the former phone is not answer and then call the next phone in sequence until the phone is get through or nobody answer the phone and automatic exit The detail setting method is see the 4 Quick start 5 Emergency key alarm When you press the disarming key the mainframe s indicator light is become to the green slow blink now the product is enter into the disarming status Unless you press the emergency key otherwise the other alarm can t trigger the mainframe to warning Note If the wireless remote controller is failure maybe it s loss the remote controller info when your mainframe return to default setting Please according to the below instruction the new wirele
10. 5900 Series GSM Remote Camera User manual Hello Welcome to use our products This product use the internal advanced wireless communication technology high technology which is development by the transducer technology It s a multifunction viewable burglar alarm This product is integration the image monitor automatic monitor automatic alarm remote control and the SMS remote control Volume is compact and have the fashion appearance It s the indispensable burglar alarm product which is suit for the household company workshop and shop use Have it you can going monitor at any time Use your mobile phone and the mailbox to check the monitor photos and the voices from the spot When you go out this product is your loyal guards Once the thieves invasion our product is built in the outstanding performance and around the clock 300 thousand pixel camera which will catch the spot photos and send the photos to your mobile phone or the mailbox At other times you also can send the instruction to our product and take a picture or monitor Even if at night you also can receive the satisfy photos This products also can connect to the market s all of the 315 435 MHz s wireless warning sensor Such as Wireless infrared body sensor wireless magnetic contacts wireless smoke sensor and so on There are mutual characteristics are the wireless connect and the installation is simple You can according to your requirements to choose one or more sensors to
11. 6 Not send short message during alarm 11 0 DX G Send the short message during the alarm default 11 1 or DX K Not send the multimedium photos during the alarm 12 0 or CX G Send the multimedium photos during the alarm default 12 1 CX K Not call the Master s mobile phone during the alarm default 2134072 or DH G Call the Master s mobile phone during the alarm 13 1 or DH K Not send the photos to the mailbox during the alarm default 2110207 FSYX G Send the photos to the mailbox during the alarm 2110214 or FSYX K Send how many photos during the alarm 33 Pieces or BJZS Pieces The pieces is from the 1 to 8 The default is 1 piece And the Max is 8 pieces If the photo size is setting to 640x480 pixel then it s only can send 2 pieces at most Note If you setting the send short message send multimedium message and calling the phone three modes at the same time the product will first send the short message and the multimedium message and then calling the phone Besides each alarm mode is only carry out one time 10 Motion detection Operation Master family The motion detection is the technology which through the discrepancy between the fore and after image to identify the illegal invasion The product must during the arming status and the motion detection function 15 open The detail arming method please see the 4 Quick start 7 Arming After success to arming the d
12. CLMD Value 5 Instruction Value can choose the 1 2 3 4 and 5 The default value is 3 The sensitivity is increase from 1 to Master and family the guest have no right Photo image size 432 valuet ZTXDX valuet 160x128 pixel pixel Instruction When the value is 1 QCIF size is When the value is 2 default CIF size is 320x240 When the value is 3 VGA size is 640x480 pixel Photo image s brightness 344 valuelt TXLD value Instruction The can choose 1 2 3 4 5 1 is means dark 5 is means highlight The default value is 4 Photo image s contrast ratio 3 8 TXDBD Instruction The can choose 1 2 3 4 5 The default value is 1 The contrast ratio is increase from 1 to 5 Photo image s direction 3 5 valuet TXFX valuet 24 Instruction Value is headstand 2 is traverse 3 is normal The default setting is 3 the message center Setting multimedium 124 multimedium message center CXZX multimedium message center 125 gateway IP Master the famil CXSZ gateway IP 4 i rd eee gateway port ZAPNZAPN ave no Or gues Setting the multimedium P user APN password right user APN password message APN parameter Instruction Detail is see 5 Advanced operation 14 setting multimedium message center and APN pa
13. The Master can according to the working time to let this product arming or disarming Open the automatic arming function Send the short message command 115 1 or ZDFS 1 Close the automatic arming function Send the short message command 115 0 or ZDFS 0 Setting the arming time range Send the short message command 116 Working day Period 1 starting time Period 1 finish time Period 2 starting time Period 2 finish time Period 3 starting time Period 3 finish time or ZDFS Working day Period 1 starting time Period 1 finish time Period 2 starting time Period 2 finish time Period 3 starting time Period 3 finish time Note Each period must according to the starting time and the finish time to setting And the starting time and the finish time can setting 1 3 three period Therefore Working day starting time and the finish time are as below Working day 1 digit figure 0 9 0 means everyday period 8 means from Monday to Friday 9 means Saturday and Sunday 1 means Monday 2 means Tuesday 3 means Wednesday 4 means Thursday 5 means Friday 6 means Saturday 7 means Sunday Starting time finish time 4 digit figure Use the 24 hours system From 0000 to 2400 The starting time must small than the finish time Such as the arming time is from pm 8 to the next day am 6 so you can setting like this 2000 2400 0000 0600 16 Chinese and the English version mutual switch Operation Master This product is support the Chinese and Engl
14. ct Disarming success This product s indication light will change to the green blink 15 8 Wireless sensor If only the wireless warning sensor s frenquency is 315 433 MHz Such as the wireless infrared body sensor wireless magnetic contacts wireless smoke sensor and so on are all can as the warning sensor to trigger this product to alarm The wireless sensor is provided by the user Add the wireless sensor Operation Master Family a Turn on the wireless sensor power and enter to the working condition b The Master or the family send any short message as below to this product the product will enter to the wireless sensor s learning status 05 Sensor description or CGQ Sensor description Therefore Sensor description is the Chinese description It s means the Master naming the each sensor in order to identify the alarm from the different sensor s warning info The description length is 20 characters Such as 05 door If you only send the 05 or CGQ and not have any sensor description This product will default setting the sensor is X X is the figure It s the sensor s figure No It s will increase from 1 After you receive short message this product is red green alternate blink and reply to short message learning the sensor During the red green alternate blink let the sensor working one time Such as If this is the wireless magnetic contact so let the magnetic contact
15. efault setting is motion detection open Note Please in the stationary circumstance to use the motion detection Such as you must let this product face to the stationary indoor circumstance and not face to the window s swing tree or the other running object or else this product will always on the warning condition If you turn on the multimedium or short message function the Master and the family will go on receive unnecessary warning info Besides it s will give rise to this product s system halted malfunction Please according to 7 General failure recovery to dispose Master or family s mobile phone can send the short message as below to this product Close the motion detection 222708 YDZC G Open the motion detection 22 YDZC K Motion detection s sensitivity 36 Value or ZCLMD Value Instruction Value can choose 1 2 3 4 and 5 Therefore the sensitivity is crescendo from 1 to 5 The default setting is 3 During the sensitivity 3 this product is sensitivity to the body size s object 11 Setting the photo image Operation Master family Setting the photo image size Master and family s mobile phone send the short message as below can setting the image to the three different size Therefore When the value is 1 the QCIF size is 160 X 128 pixel When the value is 2 CIF the size is 320 X 240 pixel When the value is 3 VGA the size is 640 X 480 pixel The system default CIF size is 320 240
16. en this product is green blink it s means on the disarming status non warning status If you want to resume this product to the arming status following have two methods to reach Method one Send any short message as follow to this product Master and the family send 01 BF Guest send 01 Password or BF Password Method two Press the remote controller s Arming key to arming When you arming success you ll receive a reply message from this product Arming success This product s indication light will change to the green constant on Default arming status Red light on Send the multimedium during the warning The motion detection function is open Multimedium image size is medium It s only send 5 pieces photo during the warning 3 pieces size is160x128 the other 2 pieces size is 320x240 The detail arming status warning type is see the 5 Advanced operation 5 Automatic warning type 7 Disarming During the disarming status this product will not give off any warning unless press the remote controller s emergency key Cancel all of the wireless sensor and the motion detection function s warning status Method one Send any short message as below to this product The Master and the family send 02 or CF Guest send 02 Password or CF Password Method two Press the remote controller s disarming key to disarm When you success you ll receive a reply message from this produ
17. ency key the product will automatic call the Master s phone No and then the Master can hear the spot voice after the phone put through 8 Inquiry the status If the user want to know the product setting and its current working status you can send the any short message to the product as below The Master and family send 407 CX The guest send 07 Password CX Password 9 Ask for help If the user forget the short message comment you can send a short message to this product to ask for the short message command table The product will reply the multimedium message and send 11 command table to user s mobile phone Ask for the common command send the any short message to this product as below and then the product will send the short message to reply the user The Master and the family send 409 1 7 1 The guest send 09 Password 1 BZ Password 1 Ask for the detail instruction Send the any short message as below to this product and then the product will send the instruction to reply the user The Master and the family send 09 1 BZ 1 The guest send 09 Password 1 or BZ Password 1 10 Return to the default setting When the product s setting status is error or the error can t resume even though power off you can through the below operation return the product to the default status Clear all of the settings including the Master s phone No to resume to the n
18. eply to you the family No is full If you repeat setting the same phone No The product will reply to you X XXXXX No is already existed Note The family s phone No can be the mobile phone telephone or handphone If it s the telephone or the handphone you must add the area code before the phone No The telephone and the handphone can t receive the multimedia message at present need the network support It s only can use the phone to monitor Inquire Operation Master Family Guest Detail is see 10 Inquire status Delete Operation Master The Master send the any short message as below to this product and delete the correspond family phone No 711132 Family s phone No SCJR Family s phone No If you only send the 113 or SCJR you can delete all the Family s phone No Regardless of you delete one family phone No or all of the family phone No when you success delete the product will send you a reply short message Success to delete the family phone No 4 Add or delete the emergency phone No Operation Master Add or delete the emergency phone No Use the Master s phone No to send any short message as below to the product Add 41067 Phone No or ZJJJ Phone No When you success to setting the product will reply to you The emergency No is success adding The No is XXXXXX If the adding No is more than 4 pieces you going to add the new phone 13 No the product will reply to you
19. er or family s mobile phone to call this product No and hang up the phone during the 4 seconds after hear the ringing And then you ll receive the multimedia message photo The other users who call the product No will be hung up and will not receive the multimedia message photo Method 2 Use your mobile phone to send any short message as below to this product The Master and the family send 03 or PZ The guest send 03 Password or PZ Password Ask for multiple photos each time If the user ask for multiple photos must use the mobile phone send any below short message to this product The Master and the family send 03 Pieces PZ Pieces The guest send 03 Password Pieces or PZ Password Pieces When the photo image s size is setting to 160 X 128 or 320 X 240 this product can be asked for 5 8 pieces photos at most each time So the photo should be from the 1 to 8 pieces When the photo image s size is setting to 640 X 480 you only can ask for 2 pieces photos at most each time So the pieces of the photo should be from the 1 or 2 After the product receive the request it s will reply the short message Already receive your request sending the multimedia message and then send the spot photos to your mobile phone 7 Monitor the spot Initiative monitor The Master mobile phone put through the product No can monitor the spot voice Emergency key monitor The user press the remote controller s emerg
20. etting all the command Emergency mobile phone No When you are at the emergency condition the user press the remote controller s emergency key alarm the product will not only call to the Master but automatic calling the emergency mobile phone No This No can be the security guard family s mobile phone No and also can be any emergency rescue phone No Only the Master have the right to setting this items The Max No of the emergency No is 5 groups 3 Installation Mainframe instruction Figure 1 Mainframe schematic diagram 1 SIM card seat rubber cover 6 Power socket standard USB port 2 Camera 7 Hanger 3 Infrared lamp 4 Indicator light 5 Power switch Remote controller instruction 8 Setting key 9 Base 10 Catching groove B o gt 1 eG 4 3 2 Remote controller Figure 2 Remote controller schematic diagram 1 Remote controller indicator lamp 2 Arming key 4 Disarming key 3 Emergency key 5 Antenna The indicator lamp s status instruction The indicator lamp represent this product s working status are as follows Color Motion Represent During the start up means to seek the Slow blink network Red Quick blink Sensor alarm The motion detection alarm During the start up if it s constant on that s Constant on means you are not loaded the SIM card or this product have the malfunction Constant on Arming status can give the alarm Slow blin
21. irport please make sure to close this products m Please don t throw this product into the naked flame or it s will give rise to the battery explosion m Please only use the orginal power adapter Use the other power adapter which is without the permission will damage this product m This product and its accessory must not touch by the children Declaration m Our company s product will go on improving and development We are reserved the right to modify and improve this files description and without the advance notice m This file is provided according to the products current situation We are reserved the right to modify and draw back this file at any time and without the advance notice The latest file info please consult to the web site s correlation content Our company must not in any way or acquiesce to guarantee this files accuracy reliability and the contents unless the applicable law have the other specified Our company must not in any way or acquiesce to guarantee this files accuracy reliability and the contents it s including but not limit to the guarantee of the marketability and the applicability m In any case our company shall not bear the responsibility of any data property and the income lost or not bear the responsibility at any special accident accessory or the indirect lost regardless of this lost is give rise by any reason m Please use this product lawfully Please not monitor other people s house and invasion
22. ish bilingual to display the prompt message Master can send the short message to choose the Chinese or English prompt langauge Choose the Chinese version short message command 127 0 or SZYY 0 Choose the English version short message command 127 1 or SZYY I1 17 Inquiry status Operation Master family guest If you want to know the display s setting condition and working status you can send the short message command as below The user will receive a multimedium message about the detail setting condition 19 Master and family send 07 or CXZT Guest send 07 Password CXZT Password 18 Ask for help Operation Master family guest If the user forget the short message command you can sent a short message command to ask for the common short message command or the detail multimedium message instruction This product will reply to you a short message or multimedium message to sent the contents to your mobile phone Short message help ask for Master and family send 2092 or BZ Guest send 09 Password or BZ Password Multimedium message help ask for Master and family send 209214 or BZ 1 Guest send 09 Password 1 or BZ Password 1 19 Return to the default setting Operation Master When this product s setting status is failure or the working is disorder you can according to the operation as below to return to the default setting clear all of the user s setting including the Ma
23. k Disarming status can t give the alarm Green Quick blink Data processing Success return to the default setting On 2 Seconds Success to learn the sensor Orange Blink Learn the remote controller status Red Green Two colors blink alternatively Learn the sensor status Installation 1 Install the SIM card Open the mainframe side s rubber cover from the upper end you can see a small dot beside the SIM card seat Press this dot one time then pop up the card seat Take out the card seat and clip the SIM card and then press the card seat back After that close the rubber cover Note This mainframe only support the China Mobile s SIM card must turn on the multimedium message function and not open the SIM card s PIN code 2 Unfold the mainframe s base Grasp the mainframe s two ends to draw Now the base s catching groove is undraw Raise the mainframe head to the up Rotate the mainframe head at the front and back left and right direction 3 Plug the external power Plug the initial switching power s one end to the power socket and the other end to the mainframe s power port 4 Fixed the mainframe Use the screw to fixed the mainframe on the wall the hanger on the base seat can use to hanging or lie the mainframe to the suitable place and aim the camera lens at the monitor district Choose the installation place m Must avoid to face the strong light source during the installation such as the window and so on s
24. matching our products to use When trigger the wireless sensor to give the alarm our product will use your prefer mode phone send multimedia message send message to alarm you your family and the security guard Even you are not choose the wireless sensor our products also can outstanding perform its responsibility You can start on its motion detection function Once anyone illegality enter to your room our product will give an alarm immediately Our product is your ideal monitor center It s will be your trustiness security defense for your daily life and the workplace All serves and functions may require the network or the SIM card to achieve The complete operation instructions and the product functions info please consult to this manual x 2 Please make sure to remember and save this products password and the SIM card No And not leak to the others in order to ensure your private location s privacy and the safety Safety Notice m This product possess a device which have the wireless signal emitter function so when you use it please make sure to far from the electrical device which is susceptible to disturb by the wireless signal in order to avoid the disturb by the electromegnetic signal 99 m During the explosion area possible to explosion area and the close the wireless received amp transmitter device or the similar slogan district such as the hospital gas station or a
25. mmand 09 BZ help 09 Password BZ Password 09 1 7 1 Ask for multimedium 09 Password 1 BZ Password 1 message instruction A Instruction Detail 1s see 4 Quick start 9 Ask for help Master The CCSZ Return to the default setting 7087 Password family and gu Password 23 est have Instruction Detail is see 4 Quick start 10 Return to the right default setting Not send the message when 2114204 DX G alarm th h Send the message when PP alarm default Don t call to the Master 13 0 DH G when alarm default ll to the Mast h E The Call to the Master when 13812 SDHEK family and alarm th Don t d the photos to th guest ave no o send the photos to the 110 0 HESYXHGH right mailbox when alarm default Send th hotos to th e photos to Wel FSYX K mailbox when alarm Don t send th ltimedi send the multimedium 412405 HCXHGH message when alarm Send the multimedium 12 1 message when alarm default Short message command Figure or phonetic User Function Figure Phonetic Close the motion detection 22 0 Y DZC G 22 1 YDZC K Open motion detection Instruction Detail is see 5 Advanced operation Master and family the guest have no right 10 motion detection Motion detection sensitivity 3 6 Faluet Z
26. modify and delete the sensor 2 Setting Chinese English version 2 Arming automatic alarm The arming status is means that the product is on the alert condition the product which connected to the wireless sensor and or the motion detection function are all on the working condition When the product is on the arming status if the wireless sensor detect the unnormal and when the motion detection are start on there are someone who come to the range of the videography the product will send the alarm multimedium message and the spot photos to the Master or automatic to calling the Master to alarm Disarming The disarming status is means that the product is disarm the alert condition the product which connected to wireless sensor and motion detection function are all on non working condition At this moment the product will not give any alarm unless press the remote controller s emergency key ask for the photograph Master family guest can send the message to the product to ask for the spot photograph Master family also can calling to the product to ask for the spot photograph require to setting Monitor on the spot Master family can calling to the product to monitor the spot voice But it s only can get through one line at the same time So the Master and the family must not monitor simultaneity Setting Through sending the instruction message to s
27. o as not to give rise to the backlight effect and influence the image quality m GSM network signal s strong and weak will effect the monitor quality and the multimedia message s sending speed Please choose the place where the network signal receiving is better to installation this product s mainframe You must avoid to install this product into the sheet iron room and inside the metal roof construction m After you installation this product please try to take some pictures and send to the mobile phone to check the effect and adjust this product s position and angle until reach the satisfy image m If you use the motion detection it is better to choose the position about 5 m to far from monitor district and avoid to appear the digital product curtain mirror and so on glisten and shake objects 4 Quick start The important instructions about the short message command 1 This product s short message have the digital and phonetic alphabet two formats The two functions are complete different You can choose any prefer format s short message command Details are see the Short message s command table 2 The Master family and the guest have the different short message format The Master and the family s short message is simple and don t need to add the password but the guest must add the password Details are see the Short message s command table guest s short message format Password is means this product s four digits n
28. on is extremely simple 10 Built in the lithium cell Can use this product as usual during the power off 11 Support the mobile phone monitor the spot and record Note The sign function only use in the enhancement mode Product accessory 1 Mainframe 1 set 2 Wireless remote controller 2 pieces 3 Switching power 5 V 600 mA 1 piece 4 User manual 1 piece 2 Terms definition Any multimedia message mobile phone can base on the password instruction to demand the spot photos Any mobile phone if it s can send the short message can through the password instruction to operation this product Therefore please make sure to remember and save this product s password and the SIM card No Don t leak to the others in order to make sure the private room s safety User rights level Our products all users are divided into three levels and have the difference rights Master The Master must save the mobile phone No to the product The detail method please see the 4 Quick start 2 Start the product Or the product will not arming and automatic alarm The product only accept the unique Master mobile phone No and the Master have all the services which is supply by our product This product only alarm to the Master s mobile phone No or the setting emergency No The Master must bear the product s password and the SIM card No in mind Only the Master can change the product s password Family The family have the right to monitor the
29. ormal working Method 1 Pull down the product s power switch Pull up the power socket and then after 20 seconds plug the power switch First press the product back s setting key and pull up the power switch untill you hear the buzzer give off two short voice DI DI That s means this product is already return to the default setting Note After the user return this product to the default setting the mainframe require to re learn the receiving of the remote controller s signal Please according to the operation of the 5 Advanced operation 4 Added new wireless remote controller Method 2 The Master s mobile phone send any short message as below to this product 08 Password or CCSZ Password Success to return to the default setting the product will reply the message Return to the default setting success At present Pull down this product s power switch and then pull up the power switch to re start this product 5 Advanced operation 1 Change password Operation Master Use the Master s mobile phone to send any short message as below to this product and then you can change the password Only the Master have the rightto change the password 04 Old password New password or Old password New passwordz Therefore the Old password is four digits password If you are not change its default password is 1234 If you change it the password is the after change password New password is your re setting 4 digi
30. pot photos to your added mailbox Add Modify the mailbox 1084 YX EMA Z EMAIL 15 mean mailbox s specify address And you only can setting one mailbox The new mailbox will replace the former one Delete mailbox 109 or SCYX 13 Infrared lamp Operation Master family The device will according to the circumstance s brightness to automatic open the infrared lamp In order to save the power you can close the infrared lamp During your close the infrared lamp you can t receive the clear photos at night And you also can t use the move detection The short message command is as below Open the infrared lamp 31 1 or HW K Close the infrared lamp 31 0 HW G 14 Setting the multimedium message center and APN parameter Operation Master Already setting the multimedium message when leave the factory So the user don t need to setting But when you at abroad or use the other supplier s SIM card you need to setting the multimedium message center The command of setting the multimedium message center is 124 multimedium center or CXZX multimedium center 18 For example 124 http mmsc monternet com The command of setting the APN short message is 125 gateway IP gateway port APN user APN password or CXSZ gateway IP gateway port APN user APN password For example 125 10 0 0 172 9201 cmwap 15 Timing automatic arming or disarming Operation Master family
31. r as soon as possible 6 In order to maintain the battery s effectiveness when you are not use this product for a long 20 time please plug power 4 hours for every 3 months The mainframe will automatic to charge the built in lithium ion 7 General troubleshooting No Troubles Possible cause Suggestion Can t start 1 Already setting Master Return to the default setting device SIM card is not open the caller ID display The function can t Contact to the operator to open 2 Not open the multimedium message acheive these function function The wrong short message center setting 1 Re insert the SIM card Can t detect the SIM card Indicator light is red 2 Check the power socket 3 The power contact is bad constant on 3 Close the SIM card s PIN The SIM card s PIN code 15 be open code After start on the Bad signal Change the installation place 4 device the red light The SIM card s PIN code is be open Close the SIM card s PIN code is always blink Insert the SIM to the mobile Can t receive the 5 The wrong short message center setting phone and setting the right reply short message short message center Can t receive the The wrong multimedium message Reference the multimedium 6 reply multimedium center setting center and the APN setting message Lack of mainframe s electric Connect the external power to quan
32. rameter Master and family Add delete the mailbox Instruction is the mailbox address you only the guest have no can setting one address if you setting the other it s will right replace the former one Delete the mailbox 109 SCYX Short message command Figure or phonetic User Function Figure Phonetic Close the infrared lamp 731508 ZHWZGZ Master and family _ Open infrared lamp 731214 ZHWZKZ O the timi 1 Den ihe MENDES ZDFS 1 disarming Close the timing arming 21154802 ZDFS 0 disarming Master and family 116 Working day ZDFS Working day the guest have no Period 1 starting time Period 1 starting time right Period 1 finish time Period 1 finish time Setting the arming time Period 2 starting time Period 2 starting time range Period 2 finish time Period 3 starting time Period 3 finish time Period 2 finish time Period 3 starting time Period 3 finish time 2055
33. spot voice demand the spot photos setting the 2055 sensor and remote controller and can send message to setting product If you want to be a family the Master must save your mobile phone No to this product The detail method please see the 4 Quick start 5 Adding or modify the family mobile phone No The family must remember the product s SIM card No Guest If you know the password and the SIM card No you ll be the guest The guest use any mobile phone to send the message instruction to the product which is including the password their can demand the spot photos and help inquire the product s condition The Master family and the guest s right different are as below User type Function Master Family Guest Change the user Permissions and password Receive the message Automatic Receive the multimedia message alarm Answering the alarm phone Receive the mail Receive the message x x Emergency Receive the multimedia message x x key alarm Answering the emergency phone 22 e e 2 Y Only the emergency phone No Call to monitor and ask for the single photograph to the mobile phone a x Send the message instruction to inquiry the status ask for the photograph help and the specification Y Need the password Ask for the photograph to the mailbox x Send the message instruction to setting x Adding
34. ss remote controller to operation Add the new wireless remote controller If the user need to add the new remote controller or the former remote controller is failure please 14 according to the below method to let this product learn how to receive remote controller signal When this product is green constant on or blink light press the mainframe back s setting key then enter into the learning status The indicator light is become to the orange slow blink Now press any key of the new remote controller to emit the info to let the mainframe to learn When the mainframe receive the new wireless remote controller s signal the mainframe s buzzer will ring to affirm After the affirm the light will change to the orange slow blink Now you can go on to learning If you are not go on to learning the new remote controller it s will automatic exit to the learning status after 15 seconds or press any setting key to exit This product can external connection with the 8 pieces wireless remote controller at most 6 Arming Operation Master Family The arming status is means when this product on the arming status all of the wireless sensors and or motion detection functions are all on the working condition if any wireless sensor or the motion detection is alarm this product will warning at once During the arming condition the motion detection function can be close alone Details are see 5 advanced operation 6 Motion detection Wh
35. ster s mobile phone No to resume to the regular work Method 1 Pull down this product s power switch After 10 seconds press the setting key and pull up the power switch and waiting until you hear the DI DI two voice then un press the setting key The green light is on 2 seconds The red light is blink Then you ll hear the voice that s means the default setting is success Method 2 Use the Master s mobile phone to sent the short message as below 08 Password or CSSZ Password After reply to the default setting you ll receive the short message Success return the default setting Note The sign function only suit to use in the enhancement type product 6 Maintenance Please according to the specify temperature to use and save this product and avoid to the hot source Over hot or over cold will damage the device 2 This product is not have the waterproof function Please remain the dry of the device and accessory Don t use this product in the bathroom or the other high humidity place Don t use and save this product in the dust place L Please use the soft humid cloth to clean this product s shell Don t use the alcohol acetone and the similar thinner to clean the shell 5 Don t open the device s shell to maintenance by yourself If your device is unnormal please according to the General troubleshooting to disposal If you also can t resolve please contact with the deale
36. tity the mainframe The remote Lack of the remote controller s electric Change the battery 7 controller is not quantity sensitivity when the Not pull out the antenna of the remote Pull out the remote controller distance is close controller antenna The mainframe is sending the multimedium message Wait a moment and retry Power adapter 8 Main technology parameter Input 100V 240V 50Hz Output 5V DC No condense EGSM900 GSM1800 5 850 PCS1900 Working temperature 10 C 45 C Storage temperature 20 C 60 C Relative humidity 10 90 Operating frequency Communication protocol Wireless sensor s receive mode Wireless sensor s receive frenquency GSM PHASE 2 2 Including the data service 315 MHz 433MHZ E Wireless sensor s allowed quantity 15 pieces Wireless remote controller s receive frenquency 315 MHz Wireless remote controller s effective distance 15m No obstacle The photo s file format JPEG The photo s resolution ratio QCIF 160x 128 320 240 VGA 640x480 The camera s resolution ratio 300 thousand pixel The camere s shooting angle 60 degree horizontal 60 degree vertical The best shooting distance at night lt 6 Built in lithium ion battery 800mAh Battery standby time 24 hours effective by the network condition Appendix Short message command table Short message command Figure or phonetic
37. ts password Please immediately change your password after you start on the product in order to ensure the operation is privacy and safety Success setting the password you ll receive a reply message from the product Password is change success new password is XXXX as 2 Change the Master s mobile phone No Operation Master Only the Master have the right to change the Master mobile phone No The Master can send any short message as below to change the Master mobile phone No 14 New Master s mobile phone XGZR New Master s mobile phone No After you success setting the Master will receive a reply short message Change the Master No The new No is The former No is ineffective 3 Add or delete the family s mobile phone No The detail different between the family and the Master please see the 2 Term definition User s right instruction The family s mobile phone No to send the command should not need to add the password Add Operation Master To be a family the Master must send the any short message as below to the product and save the family s mobile phone No into the product The Max phone No is 5 pieces 06 Family s mobile phone ZJJR Family s mobile phone No After the success setting the product will reply to you a short message Success to add the user The No is XXXXXX If the adding No is more than 5 pieces you going to add product will r
38. umerical password If you not change it the password is the default setting 1234 3 The Max Mobile phone No digits in the short message command can only have 16 4 Do not miss in short message command and letters in short messages are use upper case 1 Turn on Turn off Power on Press the power switch up The indicator lamp is from the red constant on about 3 to 5 seconds and then become to red slow blink Pass about 30 seconds the indicator lamp change to the green slow blink means disarming or green constant on means arming It s means this product find out the network and enter to the normal working condition The other detail status are see the indicator lamp instruction Power off Press the power switch down and then pull up the power socket 2 Start on the product Method 1 Use your mobile phone to call this product you ll hear that the phone is hang up after the connection That s means this product is already mutual binding with your mobile phone Method 2 Use your mobile phone send any short message as below to this product 00 When you success to according to above method to start up this product you phone will receive a reply short message from the product Welcome to use this product Success to start The password is 1234 Happy to use 3 Binding with the wireless remote controller Already binding the wireless remote controller before leave the factory
Download Pdf Manuals
Related Search
Related Contents
GG1+1 Instruction Manual SPN (viewing copy) INSTALLATION & RECOMMENDATION GUIDE AIR KV-CM1 DeLOCK 61837 card reader Samsung YH-820MC Instrukcja obsługi VPCCW2NFX/LU MONTAJE / CONFIGURACIÓN Módulo de ampliación EWM Téléchargez le règlement TED bus MANUAL DE INSTALAÇÃO E CONFIGURAÇÃO Copyright © All rights reserved.