ACCON-MPI/TS-Adapter User Manual
Contents
1. Parameter assignment of your PC adapter for an MPI network Modem connection Interfaces Add Remove Default Select Figure 6 Set PG PC Interface Choose the COM Port to which the ACCON MPI TS Adapter is connected to your PC ACCON MPI TS Adapter 12 Via Options gt Assign Parameters TS Adapter 1 11 in the TeleService software the following preferences for the ACCON MPI TS Adapter can be set Transmission rate from ACCON MPI TS Adapter to modem Assign T5 Adapter m Parameters Figure 7 Serial Parameters ACCON MPI TS Adapter 13 Modem settings Initialization string Go to the tab Modem Enter the commands needed by your modem into the field Initialization For more information please look into your modem manual Assign 5 Adapter 1 1 Parameters x Network Modem Serial Parameters Access Protection Modem Settings Initialization ATEFETLIMIGOV1 amp C150 1 Hang up Location To access an outside line first dial Dial procedure Tone dialing Pulse dialing Call Preferences Wait for dial tone before dialing Number of redial attempts ji Redial after Abbrechen Hilfe Figure 8 Setting the initialization string The complete initialization string could be like the following AT amp FE1L1M100V1 amp C1S071 AT Initiate modem com
2. Hardware Settings Data bits 8 Parity None Stop bits z Figure 5 Adjusting local modem ACCON MPI TS Adapter 11 Installation of the ACCON MPI TS Adapter at the facility Assemble the ACCON MPI TS Adapter in the cabinet keeping the indicated minimum clearance If necessary feed 24 VDC via the voltage bushing Please keep the polarity in mind Connect the ACCON MPI TS Adapter to the RS232 interface of your PC or PG via the supplied null modem cable Parametrization with TeleService The software which is used for the communication with the automation device adjusts the settings of the ACCON MPI TS Adapter In addition to the programming software STEP 7 you need the TeleService software from Siemens Version 3 0 or higher to administrate connections telephone book of the selectable plants and establish the dial connection to the PLC Adjust the connection in the dialog Set PG PC Interface as follows Set PG PC Interface Properties TS Adapter x Access Path Network Local Connection Local modem Access Point of the Application Direct connection to COM2 S7ONLINE STEP gt PC amp dapter MPI Standard for STEP 7 Transmission rate Interface Parameter Assignment Used Properties H3150 Ind Ethemet gt VMware 4 PC Adapter uto BEI PC Adapter MPI Copy PC Adapter PROFIBUS Delete
3. ACCON MPI TS Adapter User Manual The Best Solutions for PLC 1 PREFACE This manual is for project users users and assemblers who utilize the ACCON MPI TS Adapter It shows the user the handling of the ACCON MPI TS Adapter and explains signaling functions All necessary data for assembling should be provided to the assembler O 1995 2009 DELTALOGIC Automatisierungstechnik GmbH Stuttgarter Strasse 3 73525 Schwaebisch Gmuend Germany Phone sale 49 0 717 1 9 16 120 Phone support 49 0 7 171 916 112 Fax sale 49 0 7 17 1 9 16 220 Fax support 49 0 7 171 916 212 E Mail sale vertrieb deltalogic de E Mail support support deltalogic de Web site www deltalogic de All rights reserved No part of this work is allowed to be copied reproduced conferred processed and stored into electronic media or translated into any other language without a written permission of the author S7 200 S7 300 S7 400 HMI STEP and SIMATIC are registered trademarks of Siemens AG ACCON and DELTALOGIC are registered trademarks of DELTALOGIC Automatisierungstechnik GmbH Note We have checked the content of this manual for conformity with the hardware and software described Nevertheless because deviations cannot be ruled out we cannot accept any liability for complete conformity The data in this manual have been checked regularly and any necessary corrections will be included in subsequent editions We always welcome
4. at 30 C Storage 5 to 93 at 40 C Electromagnetic compatibility EMC Class B according to EN55022 Transient emissions 2kV according to EN61000 4 4 interference resistance on 6kV contact discharge method signaling lines EN61000 4 2 interference resistance ESD air discharge method Yes ACCON MPI TS Adapter EN61000 4 2 HF radiance fields 10V m according to 6 1000 4 3 Grid pound HF interferences 10V according to EN6 1000 4 6 Specials Produced according to ISO 9002 Maintenance maintenance free no battery Table 2 Technical data Pin assignment M24 VDC LTG B RTS AS M5 VDC P5 VDC P24 VDC RTS Table 3 Pin assignment Connection cable PC to ACCON MPI TS Adapter supplied with adapter Accessories for S7 Adapters 13012 HS Top hat rail holder short To assemble the ACCON MPI Adapters on a DIN hat rail 13012 24VDC External voltage supply 24 VDC for S7 Adapter For voltage supply of the ACCON MPI Adapter if there are no 24 VDC ACCON MPI TS Adapter 20
5. suggestions for improvement Last update 2008 03 18 All technical changes reserved ACCON MPI TS Adapter 1 INHALTSVERZEICHNIS PREFACE ERE Eten PI 1 2 TECHNICAL DESCRIPTION 3 9 SCOPE OF DELIVERY estie es ho ea eni Ru RUE 5 4 DEVICE DESCRIPTION eere 6 5 REQUIREMENTS FOR OPERATING 8 6 COMMISSIONING eeeeeeeeee eere entente 10 7 PARAMETRIZATION WITH ACCONFIGURATOR 17 8 TECHNICAL DATA P 19 ACCON MPI TS Adapter 2 TECHNICAL DESCRIPTION The ACCON MPI TS Adapter enables the connection of a PC to the MPI interface of a S7 PLC via modem for the purpose of remote maintenance The ACCON MPI TS Adapter uses the same communi cation protocol as the TS Adapter So the ACCON MPI TS Adapter can be used with any software which supports the TS Adapter The ACCON MPI TS Adapter can be used without the modem too In this case the device behaves like an ordinary ACCON MPI Adapter respectively PC Adapter A bushing for the connection of a further node e g a control panel console is located at the bus plug of the ACCON MPI TS Adapter To operate the ACCON MPI TS Adapter via a modem connection with STEP 7 you need the TeleService option package from Siemens When using the ACCON MPI TS Adapter in direct mode this option package is not necessary Telephone netw
6. age feed Adapter has a 24 VDC voltage feed and is ON working Firmware update BLINKING ON being executed Adapter is logged in parametrization Adapter is connected Adapter is transmitting data Tabelle 1 Status LEDs ACCON MPI TS Adapter 7 5 REQUIREMENTS FOR OPERATING Hardware requirements If possible plug the ACCON MPI TS Adapter directly on the MPI interface of a SIMATIC 57 300 or 57 400 PLC If not possible so please connect the ACCON MPI TS Adapter to an external voltage feed Please remember that the ACCON MPI TS Adapter cannot be used with PROFIBUS Software requirements To use it as programming adapter you need a PC including SIMATIC STEP 7 from version 5 1 When accessing a modem connection you need the TeleService option package from Siemens ACCON MPI TS Adapter Minimum clearance The following minimum clearance has to be kept that e can assemble and disassemble the ACCON MPI TS Adapter without disassembling other parts of the facility e there is sufficient space to connect all interfaces and connections to standard accessories e there is enough room for cable routings Figure 3 Minimum clearance Module assembly To assemble the device a top hat rail holder is necessary Available as accessory ACCON MPI TS Adapter 6 COMMISSIONING Connection to the modem Put the RS232 connection cable on the modem s RS232 port Connection to the automation system Connect the 9 p
7. d choose ACCON MPI TS Adapter Connect the ACCON MPI TS Adapter to your PC using the supplied null modem cable v3 51 o xJ i El Select com port serial number 57 adaptor v2 ROCONI Adapter Ch IN i NOCON Mellrk F ROCON RES L Adapter Conil KCICON HMU A derer E Save test ACON HPI Adapter USB E Readparsseter ECCON MPE Modem SAE gt Save parameter ACCON MP Meckan Update adapter FCCON MPI Mesgerm 35M KE adapter information Wi darei informations ACCON MPILTS Adapter E Figure 11 Select ACCON MPI TS Adapter ACCON MPI TS Adapter 17 Set the COM Port to which the ACCON MPI TS Adapter is connected under Adapter Product Select com port serial number Read out actual settings from the ACCON MPI TS Adapter and enter changes via Adapter Product gt Read parameter To store the new settings in the device click on Save End ACCOM gga or a Sd alal SEN a pil i a eo aia e e aaa a s biaa SO GO E B Settings AUCUN MPI To Adapter X 3 Ej Modem P3 MB Access protection Slaton related PRPC i the ony masi nn Ew bua Aiia 0 Net related Baud rai Highest pubponber 3 cellas Save End Ej COMI ACCOM MPI TE Adapter Figure 12 Settin
8. e eventually appearing warning Adapter parametrieren 295 40992 durch eine RHuckrufnummer gesch tzt IN Der Administrator ist weder durch ein Kennwort nach Sie eine Schutzfunktion einrichten Figure 10 Parametrizing adapter set protection The warning dialog means the following The administrator is neither protected by a password nor by a call back number Do you want to set a protection function By clicking on No all settings will be stored in the adapter despite the warning By clicking on Yes you get back to the settings Now the ACCON MPI TS Adapter is parametrized Connect the modem cable usually supplied with the modem to the RS232 port of the ACCON MPI TS Adapter and wait until the Active LED lights If not the settings of the ACCON MPI TS Adapter are incorrect normally wrong bus settings or init string and the remote maintenance is not possible The parametrization can be done locally via the TeleService software as well as via a telephone connection The ACCON MPI TS Adapter is ready to establish a remote connection when the Power LED as well as the Active LED is on ACCON MPI TS Adapter 16 7 PARAMETRIZATION WITH ACCONFIGURATOR Using ACCONfigurator it is possible to parametrize or update the ACCON MPI TS Adapter at any PC without additional software e g TeleService The program is located on the DELTALOGIC Automatisierungstechnik CD Go to Adapter Product gt select an
9. gs TS Adapter network Settings ACCON MPL TS Adapter x eee Xj m A Hoden Access protection A y FF QB Accert protection Wakem Haee Irsakz hon Hane ATARFE TLITI SeT Hang Up rali pr 7 arme cal rehus bor free tone balore dialing HPY one dali NY Pure dal Exchange numbei iod alii a HEET renege Abai have End Abort Bave End Figure 13 Settings TS Adapter modem and access protection When using ACCONfigurator it is not possible to parametrize the ACCON MPI TS Adapter via a remote connection ACCON MPI TS Adapter 18 8 TECHNICAL DATA Connection to modem RS232 with 9 pin SUB D bushing the connection has to be via the cable supplied with the modem max 115 2 KBit s Connection to PC RS232 with 9 pin SUB D bushing via supplied null modem cable ca 2 m max 115 2 KBit s Connection to PLC 9 pin SUB D plug with PG bushing cable mounted stationary ca 1 2 m max 187 5 KBit s Dimensions W x H x D in mm Protection type External voltage supply possible Power consumption Type 30 mA max 45 mA Galvanically separated Yes Operating temperature 0 C to 60 C Storage and transport 20 C to 60 C temperature Relative humidity Operating 5 to 85
10. in SUB D plug to the MPI interface of your S7 PLC Telephone network Industrial modem Automation device ACCON MPI TS Adapter Figure 4 Build up ACCON MPI TS Adapter Installation of the local modem If you already have installed an analog modem under Windows it is mostly possible to use it for remote maintenance In this case you can skip the next step and use the already installed modem After connecting to the PC plug amp play modems will be detected automatically and integrated into the system But the driver supplied with the modem is necessary No plug amp play modems can be installed manually via Control Panel Phone and Modem Options then in the tab Modems The driver supplied with the modem is needed here too Alternatively you can use a Windows standard driver e g Standard 28800 bps Modem The installed modem can be selected in the programming software when establishing a connection Example Adjusting the local modem Standard 56000 bps 90 Modem Properties ERR D T 2 x General Diagnostics Advanced General Advanced Extra Settings Call preferences Extra initialization commands f Disconnects if idle for more than mins Cancel the call if not connected within secs Port speed Data Protocol Compression Flow control Change Default Preferences Canes Standard 56000 bps 90 Modem Default Pre 2 x General Advanced
11. mands amp F Load modem factory defaults E1 Echo of commands ON L1 Sound volume level 1 ACCON MPI TS Adapter 14 1 Speaker ON QO Modem response ON V1 Response in plain text amp C1 DCD signal shows available carrier 071 Automatic call acceptance The number 1 stands for rings until call acceptance e g 50 3 the modem accepts the call after 3 rings Access protection and call back Go to the tab Access Protection Assign 5 Adapter I II Parameters E X Network Modem Serial Parameters Access Protection Administrator Password Callback number ADMIN User Password Callback number DL c 071 71916100 EE 0 5j Abbrechen Hilfe Figure 9 Access Protection Here you can store three different users including call back number and password The user ADMIN is the only one who is allowed to change all the adapter s settings and all user settings The other two users can only change their own password and call back numbers If a call back ACCON MPI TS Adapter 15 o number is set the ACCON MPI TS Adapter always utilizes this number to call back when the respective user logs in If you enter a wrong call back number for the user ADMIN the ACCON MPI TS Adapter cannot be parametrized via a remote connection any more this case you can only change the cal back number directly at the device microswitch position Ext save the settings with OK on the adapter and answer th
12. ork 7 Industrial modem ACCON MPI TS Adapter Automation device Figure 1 Build up 1 The functions DIAL and AS DIAL are not implemented ACCON MPI TS Adapter The ACCON MPI TS Adapter cannot be used with S7 200 PLCs FM35x modules cannot be parametrized with the ACCON MPI TS Adapter Features Can be used with Hayes compatible modems Password protection Call back function Can be directly used as programming adapter serial transmission rate of up to 115 2 KBit s MPI speed up to 187 5 KBit s Voltage feed from the CPU External 24 V feed possible Bus plug with PG bushing ACCON MPI TS Adapter 3 SCOPE OF DELIVERY e ACCON MPI TS Adapter e Null modem cable ca 2 m e User manual Suitable accessories can be found on www deltalogic de ACCON MPI TS Adapter 4 DEVICE DESCRIPTION Figure 2 ACCON MPI TS Adapter 1 RS232 interface for the communication with the PC Status LEDs Voltage bushing for 24 VDC Please keep the polarity in mind Bus plug with PG bushing connectable terminator and a 1 2 m connection line PC connection cable ACCON MPI TS Adapter LED Display The three LEDs on the front side of the device inform about the operating state of the ACCON MPI TS Adapter So sources of error can be detected very quickly The LEDs can be in one of three states ON OFF BLINKING Status LED Power Update Active Param Connect Data LED LED LED Adapter has no OFF volt