        User`s Manual Hygro Thermo-Anemometer + Type K/J Thermometer
         Contents
1.                      m s ft min knots km h MPH  1m s 1 196 87 2 24  1 ft min 0 00508 1 0 01138  1 knot 0 5144 101 27 1 1523  1 km h 0 2778 54 69 0 6222  1 MPH 0 4464 87 89 1                   8 407412A EN v1 1 07 13    Warranty       FLIR Systems  Inc  warrants this Extech Instruments brand device to be free of defects in parts and workmanship for one year  from date of shipment  a six month limited warranty applies to sensors and cables   If it should become necessary to return the  instrument for service during or beyond the warranty period  contact the Customer Service Department for authorization  Visit  the website www extech com for contact information  A Return Authorization  RA  number must be issued before any product is  returned  The sender is responsible for shipping charges  freight  insurance and proper packaging to prevent damage in transit   This warranty does not apply to defects resulting from action of the user such as misuse  improper wiring  operation outside of  specification  improper maintenance or repair  or unauthorized modification  FLIR Systems  Inc  specifically disclaims any implied  warranties or merchantability or fitness for a specific purpose and will not be liable for any direct  indirect  incidental or  consequential damages  FLIR   s total liability is limited to repair or replacement of the product  The warranty set forth above is  inclusive and no other warranty  whether written or oral  is expressed or implied     Calibration  Repair  a
2.  Setup Mode described in a previous section of this manual     Battery Replacement       When it is time to replace the 9V battery  the low battery indicator appears in the top left hand  corner of the LCD display  Note that reliable readings can be obtained for several hours after the  first appearance of the low battery indicator    To replace the battery     1  Remove the meter s protective rubber holster     2  Open the battery compartment on the back of the meter using a small coin or a flat blade  screwdriver     3  Replace the 9V battery  close the compartment  and replace the holster     5 407412A EN v1 1 07 13    Specifications       General Specifications    Display Dual function  4 digit  9999 count  LCD display    Units of measure m s  meters per second   km hr  kilometers per hour   ft min  feet per  minute   knots  nautical miles per hour   mile hr  miles per hour      Temperature    C   F  Humidity   RH    Data hold Holds reading on the LCD display when button is pressed    Air velocity sensor  Twisted vane arm with low friction ball bearing   Temperature  Precision thermistor  Humidity  Thin film capacitor   Temperature  Type K J thermocouple   Records highest and lowest readings for later recall   RS 232 serial PC interface   32  F to 122  F  0  C to 50  C    Max  80  RH   Approx 114mADC  Anemometer   7mADC  RH   SMADC  Type K J     Weight 0 77 Ibs   350g     Dimensions Meter  7 1x2 8x1 3   180 x 72 x 32mm      Anemometer Probe  2 8   72mm  Diameter x 5 5   1
3.  v1 1 07 13    Anemometer and Temperature Operation       Insert the Vane sensor into the meter s input jack at the top of the meter     2  Press the POWER button to turn the instrument on and it will automatically recognize the  connected probe    3  The Air Velocity display will default to the settings when the      unit was last powered off   lt  lt   To change settings  refer to the Setup Mode described below    5  For maximum accuracy  the yellow dot must be on the a Aiow  exhaust side of the vane as shown  2   6  The meter   s LCD will indicate Air Velocity   Temperature    Setup Mode    Press and Hold the SETTING button for  gt 5 seconds to enter setup mode  Use the SETTING Button  to select the function listed below  To select the desired unit  press the FUNCTION button  Press  the ENTER button to store the selection  Momentarily press the POWER button to exit the setup    mode    1  Unit  Changes the air velocity measurement unit  m s  km hr  ft min  knots   amp  mile h    Anemometer probe only    2  K  Changes the thermocouple type  K or J   Thermocouple probe only    3    C  Changes the temperature unit of measure    C or   F   Anemometer  Humidity  and  Thermocouple probes    4  OFF  Auto Power Off control  Yes No   Anemometer  Humidity  and Thermocouple probes    5  Code  Code entering for factory calibration     Relative Humidity and Temperature Operation       Insert the Relative Humidity probe in the input jack at the top of the meter     Press the POWER butto
4. 40mm     Anemometer temperature and RH Probes  9V battery   amp  case          6 407412A EN v1 1 07 13    Range Specifications    Air velocity    Measurement Accuracy    of reading   ft min  feet min  80   4930 ft min  1 ft min    2    40 ft min   m s  meters sec  0 4   25 00 m s  0 01 m s    2    0 2 m sec     km h  kilometers hour  1 4 90 0 km h  0 1 km h    2    0 8 km hr   mph  miles hour  0 9   55 9 mph 0 1 mph    2    0 4 mph   knots  nautical miles hour    0 8 to 48 6 knots  0 1 knots    2    0 4 knots     Temperature    32  F to 122  F  0  C to 50  C   1 5  F    0 8  C   Relative Humidity    Thermocouple Temperature           58  F to 2372  F   50  C to 1300  C 0 1  F   C    0 4    1 5  F   0 8  C       327  F to  58  F   199  C to  50  C  0 1  F   C    0 4    1 8  F    1  C      Type J     58  F to 2012  F   50  C to 1100  C  0 1  F   C    0 4    1 5  F   0 8 C     327  F to  58  F   199  C to  50  C  0 1  F   C    0 4    1 8  F    1  C         7 407412A EN v1 1 07 13    Appendix       Area equation for rectangular or square ducts    Height  H     Area  A    Width  W  x Height  H   Width  W     Area equation for circular ducts    Area  A       x r   Where      3 14 and r     radius x    radius    Cubic equations    CFM  ft min    Air Velocity  ft min  x Area  ft      CMM  m  min    Air Velocity  m sec  x Area  m    x 60       NOTE  Measurements made in inches  must be converted to feet or meters before using the above formulae        Unit of Measure Conversion Table 
5. EXTECH User s Manual    INSTRUMENTS          Hygro Thermo Anemometer    Type K J Thermometer    Model 407412A         E     POWER    SETTING       N  SSS    RS 232  OUTPUT    Introduction       Congratulations on your purchase of Extech s Hygro Thermo Anemometer  This Heavy Duty meter  measures and displays Air Velocity   Temperature  Relative Humidity   Temperature and Type K J  Temperature  Air flow can be displayed in the following units of measure  feet per minute  meters  per second  miles per hour  kilometers per hour  and knots  Temperature and RH units are  displayed in   C   F and   units respectively  This meter is shipped fully tested and calibrated and   with proper use  will provide years of reliable service     Meter Description       02  Oy  01    Type K J thermocouple input plug    Sensor input plug     The Anemometer sensor and the Humidity sensor use the same jack at  the top of the meter     LCD Display  Keypad  see below   POWER Press to turn the meter ON or OFF    HOLD FUNCTION Press to freeze the currently displayed reading Selects unit in setup mode   selects Probe  left position  or Thermocouple  right position     REC ENTER Press to track the MAX and MIN readings Press to enter selection in setup mode  SETTING Press to enter setup mode   RS 232 Serial interface jack   Battery compartment and tilt sand are located on the back of the meter   Rubber protective jacket  Vane Anemometer sensor       Humidity sensor                               2 407412A EN
6. later recall   To use Record mode     1   2   3     Press the REC button  The REC indicator will appear on the LCD display   Start a measurement session     After the measurement session  press the REC button to view the highest  Max  reading  recorded  The MAX indicator will appear to inform the user that the displayed reading is the  highest value recorded  Momentarily press the HOLD button to continue recording     Press the REC button again to view the lowest reading  The MIN indicator will appear on the  LCD to inform the user that the reading displayed is the lowest value recorded  Momentarily  press the HOLD button to continue recording     Press and Hold the REC for 2 seconds to return the meter to normal operation  All stored data  will be cleared and the REC MIN MAX icons will disappear from the LCD     Note that putting the meter into the Record mode defeats the Auto Power Off feature     4 407412A EN v1 1 07 13    RS 232 PC Interface       The RS 232 serial data port  3 5mm phono jack  is located on the face of the meter  The PC  interface hardware is intended for use with the Extech Data Acquisition software package  Part  Number 407001 which includes Windows    95   98   ME   NT   2000  XP compatible software and  PC interface cable  For more information  contact Extech or refer to the 407001 User s Manual     Auto Power Off feature       The Auto Power Off feature automatically turns the meter off after approximately 10 minutes  This  feature can be defeated in
7. n to turn on the instrument and it will automatically recognize the  connected probe     The Humidity mode of operation will default to the settings when the unit was last powered off     To change the temperature units of measure  refer to the Setup Mode described in the  previous section of this manual     Hold the probe by the handle in the area to be monitored  The meter will display Relative  Humidity   Temperature     Note that humidity measurements take several minutes to stabilize     3 407412A EN v1 1 07 13    Type K J Temperature Operation       Insert the thermocouple into the meter s thermocouple input jack at the top of the meter     2  Press the POWER button to turn the instrument on and it will automatically recognize the  connected probe     3  The Air Velocity display will default to the settings when the unit was last powered off     4  To change settings  refer to the Setup Mode described in the previous section of this  manual     Note  The Thermocouple probe can be inserted into the meter at the same time as the  Anemometer or RH Temperature probe  To alternate between the inserted probes  press and  hold the FUNCTION button for more than 2 seconds     Data Hold       Press the HOLD button to freeze the displayed reading  The HOLD icon will appear on the LCD  while Data Hold is engaged  Press the HOLD button again to resume normal operation     Min Max Record Mode       When selected  the Record mode stores the highest  Max  and lowest  Min  readings for 
8. nd Customer Care Services       FLIR Systems  Inc  offers repair and calibration services for the Extech Instruments products we  sell  NIST certification for most products is also provided  Call the Customer Service Department for  information on calibration services available for this product  Annual calibrations should be  performed to verify meter performance and accuracy  Technical support and general customer  service is also provided  refer to the contact information provided below     Support Lines  U S   877  439 8324  International   1  603  324 7800    Technical Support  Option 3  E mail  support extech com  Repair  amp  Returns  Option 4  E mail  repair extech com  Product specifications are subject to change without notice  Please visit our website for the most up to date information  www extech com  FLIR Commercial Systems  Inc   9 Townsend West  Nashua  NH 03063 USA  ISO 9001 Certified       Copyright    2013 FLIR Systems  Inc     All rights reserved including the right of reproduction in whole or in part in any form    www extech com    9 407412A EN v1 1 07 13    
    