Home

STAGE BAR 16 USER MANUAL

image

Contents

1. STAGE BAR 16 Order code LEDJ160 USER MANUAL STAGE BAR 16 SAFETY WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty STAGE BAR 16 SAFETY IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution e Never remove warning or informative labels from the equipment e Do not open the equipment and do not modify the equipment
2. e Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors Do not expose to flammable sources liquids or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable e Make sure that the available voltage is between 220v 240v e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again e If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature e If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service e Only use fuses of same type and rating e Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS e WARRANTY One year from date of purchase OPERATING DETE
3. Off 99 On Flash speed values 00 Off 99 Fast STAGE BAR 16 DMX PROGRAMME CHARTS 4 channel mode DMX chart 6 channel mode DMX chart 1 5 Sound 6 10 On 11 255 Flash 19 channel mode DMX chart CH10 CH11 CH13 CH14 CH15 CH16 CH17 CH18 CH19 BLACKOUT 6 10 0 255 0 255 E 255 A 255 o 255 Se 255 DIMMER ALL Flash es Ai E Ea Bess Eil u a a a a a a a 21 25 0 255 55 kaila A HS EE ES RE ER ER ER KEES fa EE ee ee 0 255 a Lal eend DR ER 36 40 0 255 55 ea Lal ree TT DEE RE RE HE 41 45 0 255 55 ee J seal een O KK AH AEA NE AES A KE RE FREE FR 0 255 Ce seal ar Y pp tp 1 51 55 0 255 55 Le Lasel Gel JL 56 60 0 255 55 Le Lal res OL RE RE DE RE RE HR RE RE HE 0 255 se 66 70 0 255 55 rea seal eend ER DEE ER RE KR 71 75 0 255 55 lnea seal zl 86 90 0 255 55 J econ specs rn 7 S F T 91 100 0 255 il Ec A AAA jump 101 110 0 255 55 E E A AA fade 111 120 0 255 Dreaming Specs Fish 121 130 0 255 55 er GG AN 131 140 0 255 55 sje RES RE RE RE EHRE 0 255 5 ee 0 255 ee ee RE Colour select sere TT rrr rr yee select select 181 190 0 255 55 55 0 255 ENANA select select 191 200 0 255 55 55 0 255 EA select select 201 210 0 255 55 0 255 E GERS RES ERR SSES SES Colour select select 211 25
4. 5 0 255 SOUND Sens STAGE BAR 16 DMX SET UP DMX 512 e DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation e The Stage Bar 16 can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input
5. RMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property STAGE BAR 16 INTRODUCTION Introduction Features e DMX channels 19 6 4 selectable e 16 Ultra Bright 3W LEDs R 4 G 4 B 4 A 4 e Sound activated Auto run Master slave and DMX modes e Sound control via internal microphone e 13 built in programmes Consumption 60W Beam 25 degrees e Lamp life 100 000 hours Over view DMX Out LCD Screen DMX In POWER ouT 5 Ces NB Stage Bar 16 Mm ODE SETUP up Mode Button Up Button Power In Power Out Down Button Set Up Button Setup Operating Instructions The Stage Bar 16 is a DMX 512 controllable unit made up of high efficiency and Ultra bright LEDs and will operate in auto run master slave sound activated or DMX control modes STAGE BAR 16 OPERATION MODES Operation modes Sound Active mode To activate the unit in sound active mode press the MODE button to show SOUND MODE on the LCD screen Now press the SET UP button to select the desired sensitivity level by using the UP and DOWN buttons Press th
6. ash 00 99 12 Two Way Speed 00 99 Flash 00 99 13 Two Colour Speed 00 99 Flash 00 99 STAGE BAR 16 BUILT IN PROGRAMME CHART 13 Built in programme chart Static colour selection R 00 99 G 00 99 B 00 99 A 00 99 NB See static colour selection below Jumps through its built in 15 colours one after the other Speed and flash adjustable 15 colour fade in fade out Speed and flash adjustable 15 colour fade Speed and flash adjustable 15 colour flow from left to right Speed and flash adjustable 15 colour flow from left to right right to left Speed and flash adjustable 15 colour chase from left to right right to left Speed and flash adjustable Multi colour chase from left to right Speed and flash adjustable 15 colour fade flow from left to right Speed and flash adjustable 2 colour flow from left to right Speed and flash adjustable 2 colour chase from left to right Speed and flash adjustable 2 colour flow from left to right right to left Speed and flash adjustable 2 colour chase from left to right right to left Speed and flash adjustable Static colour selection To select a static colour press the MODE button to show 01 STATIC on the LCD screen Now press the SETUP button to select the desired light output value of each individual colour for example for RED and AMBER on only set the values to R 99 G 00 B 00 A99 Light output values 00
7. djust by using the UP and DOWN buttons Press the SET UP button once more to select the desired flash value and adjust by using the UP and DOWN buttons Speed values 00 99 00 slow 99 fast Flash values 00 99 00 slow 99 fast For the 13 built in programmes please see page 5 DMX mode To activate the unit in DMX mode press the MODE button to show DMX MODE on the LCD screen Press the SET UP button and select the desired DMX address setting by using the UP and DOWN buttons Then to select one of the 3 DMX modes 19 6 or 4 channel press the SET UP button again to choose the desired DMX mode by using the UP and DOWN buttons For the 19 6 and 4 channel DMX address information please see page 6 NOTE Once the desired settings have been selected in all of the modes ALWAYS confirm the settings by pressing the SET UP button 01 Static colour Blackout RGBA Flash 00 99 02 Colour Jump Speed 00 99 Flash 00 99 03 Colour Fade Speed 00 99 Flash 00 99 04 Colour Dream Speed 00 99 Flash 00 99 05 Colour Flow Speed 00 99 Flash 00 99 06 Colour Overlap Flow Speed 00 99 Flash 00 99 07 Colour Chase Speed 00 99 Flash 00 99 08 Multi Colour Speed 00 99 Flash 00 99 09 Fade Flow Speed 00 99 Flash 00 99 10 Two Flow Speed 00 99 Flash 00 99 11 One Way Speed 00 99 Fl
8. e SET UP button again to select the frequency number and adjust by using the UP and DOWN buttons SENS 00 31 00 low 31 high FQN 01 99 01 low 99 high Auto run mode To activate the unit in auto run mode press the MODE button to show AUTO RUN on the LCD screen Now press the SET UP button to select the desired frequency number by using the UP and DOWN buttons FQN 01 99 01 low 99 high Note When the Stage Bar 16 is set to SOUND or AUTO RUN mode it will scroll through all of its built in programmes one after the other The term FQN refers to the number of times it displays the buit in programmes for example if you set the FQN to 3 it will then repeat each programme 3 times before going on to the next one Slave mode To activate the unit in slave mode first you must link multiple units together and press the MODE button to show SLAVE MODE on the LCD screen Now on the master unit press the MODE button to select the desired mode and the slave units will now run in sequence with the master unit Built in programmes To activate the units built in programmes press the MODE button to show 01 STATIC on the LCD screen Press the SET UP button to choose between the 13 built in programmes by using the UP and DOWN buttons Now press the SET UP button to select the desired speed and a
9. output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split STAGE BAR 16 DMX SET UP Notice e Be sure to follow figures 2 4 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out DMX 512 in 3 pin XLR 3 pin XLR MATH AA XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground O Pin 2 Negative ee FIGURE 3 FIGURE 2 Special Note Line termination e When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems O and interferance it is always advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting
10. standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The chart below details the correct cable conversion 3 Pin XLR to 5 PIN XLR Conversion Conductor 3 Pin XLR out 5 Pin XLR in Ground shield Pin 1 Pin 1 Negative Pin 2 Pin 2 Positive Pin 3 Pin 3 STAGE BAR 16 TECHNICAL SPECIFICATIONS Technical Specifications Weight amp Dimensions i E nee 550mm WI a 120mm all OT 155mm Wei 3 6kgs Power SAG IN PU bic ina 240V 50hz e Power consumption 1ws 60W e Fuse S MAN SE 2A 240V Control amp Programming Data NP Locking 3 pin XLR male socket e Data OU UI ir aa md in antava aa Locking 3 pin XLR female socket Stot Eege eebe DMX 512 USITT DMX CchannelS uu 19 6 and 4 CREATE THE RIGHT EFFECT www prolight co uk