1. 49 30 63 92 7011 E mail sales 9 mgb berlin de Internet www mgb berlin de
2. We BRIGHTNESS Natural Illumination FO ________________ 300 W Xenon light sources provide illumination in daylight quality The natural light composed of the entire spectrum of white light is the optimum for endoscopic surgery Automatic Light Adjustment GH CG C f In combination with the camera the ML L continually optimises the brightness for viewing flat and deep structures inside the body The brightness may also be adjusted manually Lamp Exchange GH 1 OQOQ DD The lamp has an average life of 500 hours A counter is situated on the front display With integrated replacement indicator amp 3 integrated silent fans control the temperature stability Safety Operation EEE The 300 W Xenon lamp and the 150 W Halogen lamp for emergency guarantee safe operation Order No 685 00400 Universal Light Guide Connector Port The universal light guide connector port allows the use of different light guides without paying any attention for having the right adapter Emergency Lamp An integrated unique 150 Watt emergency lamp for backup User Friendly Display The ML L control panel is robust clearly and ergonomically arranged GENERAL 685 00400 ML L Light source Power supply 100 120 VAC 200 230 VAC Safety class with potential equalization connection Approval C Dimension w h d 400 x 160 x 360 mm Operating temperature 10 C 40 C Operating humidity 30
3. www mgb berlin de ML VHD 3 CCD Endo Camera ML V 3 CCD Endo Camera MS V 1 CCD Endo Camera ELICA FENCER the Complete Laparoscopic Unit Video Camera Lens ML L Light Source 300 W Xenon MS L Light Source 180 W Xenon MS LH Light Source 250 W Halogen Light Guides and Adapter ME GX Insufflator ML GX Insufflator Monitors EC 2000 A Endo Cart Isolation Transformer Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 3l MGB 24 HD Monitor Flat Screen MGB ML G Insufflator MGB ML VHD 3 CCD HD Endo Camera MGB ML L Light Source 300 W Xenon MGB Disto Il Video Documentation EC 2000 A Endo Cart G D HD TECHNOLOGY CORE COMPETENCES 1920 x 1080 px 720 x 576 px 4 3 MGB s ML VHD is using a high end broadcast HD 3 CCD image sensor with Endoscopy 5 times more pixel than standard CCD image sensors for PAL or NTSC format The HD format is specified with 16 9 instead of PAL or NTSC standard 4 3 MGB s ML VHD is using a 1 3 CCD image sensor The resulting pixel size is larger than pixels of PAL or NTSC 1 3 CCD image sensors It allows perfect imaging of micro structures MGB s HD telescopes as well as HD video camera lenses are designed to t
4. 120 VAC 200 230 VAC Safety class 1 Type BF Dimension w h d 530 x 200 x 440 mm FENCER PAL or NTSC type lI Camera head ind cable IB Silicon tube for Insufflator E Silicon tube for Irrigator E Regulator with manometer and snap in connector E Power supply cable and BNC cable Light Soure 180 WXENON O Lamp type Xenon 180 W Side door with cartridge Life cyde of lamp Approx 500 hours m s Jegen po NN 30 L min maximum Bl 1 5 L min minimum MGB snap in DIN Gas input pressure 4 10 bar high pressure pressure reducer included SPECIFICATION CCD Sensor Size 1 3 NTSC H X V 768 x 494 410 000 pixels PAL H X V 162 x 582 440 000 pixels Die Shutter speed Automatic control between 1 60 1 100 000 sec NTSC 1 50 1 100 000 sec PAL e Horizontal resolution 450 TV lines Y C S video x 1 at 75 Q composite x at 5 f 16 34 mm 470 28000 C mount f 18 mm 470 23400 C mount circular frame picture f 22 mm 470 27400 C mount limited frame picture f 25 mm 470 24400 C mount full frame picture 30 mm 470 25400 C mount full frame picture f 40 mm 470 26400 C mount full frame picture Urology Video Camera Lens 90 f 18 mm 470 30000 C mount circular frame picture Light guide for example 402 11300 f 4 8 mm length 2 3 m 686 00200 Spare lamp Xenon 180 W 675 11203 Filter for insufflation conus 15 mm 25 p
5. 768 x 494 hx v x 3 Automatic adjustment Set Brightness control screen display confirmation Digital zoom Set button Head dimension w h d Head weight 134 g ind cable 3m Lens connection C mount Waterproof IP X7 2 Head buttons 1 x selec Button A print Button B W B Gain Z00M f 16 34 mm 470 28000 mount f 18 mm 470 23400 C mount circular frame picture 22 mm 470 27400 C mount limited frame picture f 25 mm 470 24400 C mount full frame picture 30 mm 470 25400 C mount full frame picture f 40 mm 470 26400 C mount full frame picture D Urology Video Camera Lens 90 f 18 mm 470 30000 C mount circular frame picture MS V 1 CCD ENDO CAMERA Higher Contrast The Endo Camera MS V can provide an enhanced resolution Even fine tissue structures can be visualized with its detailed transmission Camera Head Design SL The Endo Camera MS V is specially designed for endoscopic procedures The angled camera head gives a perfect sense of up and down to the user The new camera is much lighter and smaller The head button is individual selectable White Balance Memory Function SS The white balance setting is stored in the camera s micro processor Thus the correct adjustment is kept even if the Endo Camera MS V is switched off Order No 670 15000 Head Button Individual selectable head button N B Print and Gain switc
6. FENCER is based on the latest digital technology The microprocessor controls brightness through shutter control and white balance that result in clear and sharp images for endoscopy everytime Xenon Light Source with Manual Regulation The 180 W Xenon Light Source provide illumination The natural light composed of the entire spectrum of white light is the optimum for laparoscopic surgery Users can replace lamps quickly and easily Irrigation The Irrigation part in FENCER has a high pressure Irrigation function In combina tion with the MGB Suction Irrigation instruments and easy handling high flow Irrigation is guaranteed and constant in 1OGrated Laparo amp copc Surgical System FE N C E R f wi Pm Ps mmHg Q Let A INSUFFLATION ZN PRESSURE FLOW e Y M WHITE BALANCE mE _ IRRIGATION lt D Order No 675 11000 FOUR IN ONE lB Gas Insufflator Ii Video Camera Ii Light Source Bi Irrigator FENCER is a complete laparoscopic system A combination of Insufflator IB CCD Video Camera lll Xenon Light Source Bi Irrigation in one compact unit Each funcion working independently from the other FENCER allows high performance for laparos copic applications Additionally FENCER is designed for simple and user friendly operation Gas Insufflator Video Camera Light Source Irrigation GENERAL LK Power supply 100
7. Adapter for insufflation m Silicone tube set for irrigation m Power cable m User manual C0 connection m Irrigation connection Luer male m DIN SPECIFICATION m Low adjustable from 1 to 45 l min preset 2 l min m Med adjustable from 1 to 45 l min preset 8 l min m High adjustable from 1 to 45 min preset 40 l min m Automatic flow profile depens on Low Med and High flow rate setting m Intermittent or continuous flow mode Insufflation medium 0 Insufflation rate m Adjustable in the range of 3 30 mmHG m Maximal pressure of bottle 100 bar Intra abdominal working pressure LAN MEN Silicone tube set for insufflation MONITOR AMM240WTD 24 FU LL MON ITOR Order No 470 43200 AMM213TD 21 3 HD Monitor Order No 470 43300 Product Line The new MGB monitors cover all the needs in the endoscopic field The 21 3 HD monitor is recommend for the use with our MS V and ML V cameras while the HD 24 monitor is intended for the use with our ML VHD HD camera Base Stand Order No 470 43210 Medical Grade RSS All monitors are sealed to ensure proper cleaning In addition each model also features Seolforbio TechnologyTM which provides an internal anti bacterial coating for added protection Flexibility GH 8 ll Each model can easily be mounted on a wall ceiling or an extended arm VESA compliance as well as put on a cart
8. by using its optional base stand Multiple Pictures Modes GH C C 1 2 The AMM213TD and the AMM240WTD support true Picture in Picture PIP Picture on Picture POP and Picture by Picture PBP Mode with independent adjustment These flexible display modes can be used for special applications such as to view both live video and captured images simultaneously for more comprehensive coverage of the surgical procedure Easy Control SSS The user friendly On Screen Display OSD allows easy adjustment of the set tings The new Jog Dial control of the AMM214TD and the AMM240WTD makes the control even easier Product Order No 213 470 43300 AMM240WTD 470 43200 LCD Panel Resolution Colors Brightness Contrast Ratio Viewing Angle 1 3 TFT Panel 600 x 1200 dots 1 50 cd m 85 H 85 V N 24 TFT Panel 1920 x 1200 dots 400 cd m 16 7 M 85 85 V Input Loop Through Remote Operating Temperature Storage Temperature Humidity Operating Pressure B 011 1 I HD 15 I D HD SDI 1 and 2 E Component YPbPr IB C Video IB S Video SD HD SDI E Component YPbPr IB C Video E S Video DVI 15 I SD HD SDI 1 and 2 E Component YPbPr WC Ven E S Video SD HD SDI E Component YPbPr WC Ven E S Video DB 9 RS 232 DB 9 RS 232 10 40 C 50 104 F 20 60 C 4 140 F 3
9. ee Dimension w x d h 380 x 340 x 120 mm Operating temperature 10 C to 40 Operating humidity 30 to 75 RH m Silicone tube set for insufflation m Disposable filter for insufflation m Adapter for insufflation m Power cable m User manual SPECIFICATION m Low approx 2 min m Med approx 10 min m High approx 30 l min m Auto continuous flow Insufflation medium 0 Insufflation rate m Adjustable in the range of 3 30 mmHG continuously Maximum pressure of bottle 100 bar m Display of critical low bottle pressure Intra abdominal working pressure 670 95300 Silicone tube set for insufflation 670 95310 02 gas bottle 11 empty 670 95311 Key for 02 gas bottle connection 670 95313 High pressure tube GI DIN bottle DIN 670 95314 High pressure tube GI DIN bottle PIN 670 95316 High pressure tube GI DIN bottle ITALY See Laparoscopic folder Verres needle different lengths 675 11200 Filter for insufflation conus 15 mm 25 pcs 675 11202 Adaptor for insufflation ML GX INSUFFLATOR Abdominal Pressure Flow wm pr LN Ki o j We GB ge Di oe T Specification EL 7 71 98 Up to user s choice operating in continuous or intermittent mode ensures suitability to any endo scopic application Additional irrigation function and optional heating complete this device High Safety h m jj Safety is more imp
10. picture BRIGHTNESS Higher Contrast The Endo Camera ELICA can provide an enhanced resolution Even fine tissue structures can be visualized with its detailed transmission Great Light Sensitivity Under difficult light conditions the Endo Camera ELICA II is showing a well illuminated picture For small diameter telescope s digital filters allow to enhance the sharpness New Camera Head Design The Endo Camera ELICA II is specially designed for endoscopic procedures The angled camera head gives a perfect sense of up and down to the user White Balance Memory Function The white balance setting is stored in the camera s micro processor Thus the correct adjustment is kept even if the Endo Camera ELICA II is switched off ELICA Il VIDEO CAMERA COMBINED WITH DUO LIGHT SOQURCE Order No 670 51500 Head Button Individual selectable head button m W B White balance m Print Remote to recorder device m Sharp Sharpness switch on the backside Moir Function Allows to use flexible Fibrescopes Brightness Light intensity regulation Freeze and Screen Splitting optional ELICA II allows freeze and screen splitting on the monitor for detailed comparison GENERAL 670 51500 ELICA Il PAL 100 230 V 670 52500 ELICA II NTSC 100 230 V 670 51510 ELICA Il PAL 100 230 V 670 52510 ELICA 11 NTSC 100 230 V with potential equalization connection ce Dimen
11. 0 75 no condensation 700 1060 hPa 10 40 C 50 104 F 20 60 C 4 140 F 30 75 no condensation 700 1060 hPa Dimension in cm w x h x d Dimension in inches w x h x d Weight in kg Ib 512 x 389 x 85 20 0 x 15 31 x 3 3 6 66 kg 14 65 10 598 382 9 x 111 5 23 54 x 15 07 x 4 39 7 47 kg 16 45 Ib Display Monitor AC Adapter DC 24 V AC 100 240 V 50 60 Hz DC 24 V AC 100 240 V 50 60 Hz Safety AMY amp Environmental Standard I UL 60601 1 IB EN 60601 1 IM EN 60601 1 2 B FCC i CCC VCC RoHS E IP X 1 Comliance Il AC Power Cord Il AC Adapter E Video Cables E User Manual UL 60601 1 IB EN 60601 1 EN 60601 1 2 B FCC CE I IB VCCI RoHS E IP X 1 Comliance E AC Power Cord Il AC Adopter E Video Cables E User Manual Oo Base Stand Order No 470 43210 WW Base Stand Order No 470 43210 G D E N DO CA RT EC 2000 A Order No 670 80610 Cable channel Intended Use I _ lI Large cable channel with potential equalization pins and cover IB Gliding wheels with locking brakes lI Surface metal powder coating easy cleaning resistant to disinfecting agents lI Dimension w h d 1390 mm x 710 mmx 700 mm IB Distance between stands 185 mm lll Space for units w d 600 mm x 480 mm IB Weight 57 kg E Stand for gas bottle 180 mm x 190 mm lI Stand for Suction Irrigation bo
12. 5 Operating temperature 10 C 40 C Operating humidity 30 5 ML L E Power cable Bl User manual SPECIFICATION ie s O 685 00200 Spare lamp 300 W Xenon 681 00100 Spare lamp 150 W Halogen High performance light guide 402 11410 LG 310 W length 2 3 m High performance light guide 402 11510 LG 310 W length 3 0 m KE 363159 Potential equalization cable 1 m 5 1 MS L LIGHT SOURCE 180 W Order No 686 10000 Universal Light Guide Connector Port The universal light guide connector port allows the use of different light guides without paying any attention for having the right adapter Natural Illumination Em 88080 180 W Xenon light sources provide illumination in daylight quality The natural light composed of the entire spectrum of white light is the optimum for endoscopic surgery fr Replacement Indicator CHANGE Xenon Lamp eege The lamp has an average life of 500 hours A counter is situated on the front display Light Regulation Manual light regulation provides exact illumination control Light Regulation _ Manual light regulation provides exact illumination control User Friendly Display Ss 1 1 1 72 8 The MS L control panel is robust and clearly arranged Simple controls allow effective cleaning Lamp Exchange GH CG C The lamp has an average life of 500 hours A counter is situated on the display With integrated replac
13. cs 670 95300 Silicone tube set for Insufflation 675 95301 Silicone tube set for Irrigation 675 11202 Adapter for Insufflation VIDEO CAMERA LENS Video Camera Zoom Lens HD Video Camera Zoom Lens So E f 16 34mm E 18 28 mm HD Video Camera Lens wa E f 25 Video Camera Lens nnii f 18 mm used in Arthroscopy Urology ENT f 22 mm used in ENT W f 25 mm used in Laparoscopy E f 30 mm B f A0 mm Urology Video Camera Lens 90 GS C _ E 18 mm lt D GENERAL 470 28000 f 16 34 mm 470 29000 f 18 28 mm 9 A Laparoscopy Full Size with 1 3 CCD f 25 mm SPECIFICATION f 18 28 mm Limited Size Sinoscopy 4 mm f 22 mm ll Zoom E One of the E C mount shortest and E Used in all en very light doscopic fields weight zoom parafocal in the market Bl Zoom E HD resolution E C mount E Brilliant optic E High translucence E Quick endoscope coupling E Waterproof E C mount E Ergonomic design E HD resolution WC mount E Full frame picture with HD Lapalux II Angled video lens with rotatable eyepiece connector H Rotation lockable Focal length f 18 mm circular frame picture II Connection to camera head C mount BI Une hond operation W Air ventilation on ocular window BI Soakable Arthroscopy Urology Circle Size Arthroscopy 0 4 mm f 18 mm BRIGHTNESS DOWN
14. ement indicator 3 integrated silent fans control the temperature stability GENERAL 686 10000 MS L Light source Power supply 100 120 VAC 200 230 VAC he 2x 73 15 aL 250 Gn S Safety class with potential equalization connection Dimension w h d 395 x 120 x 340 mm Operating humidity 30 5 MS L E Power cable Bl User manual SPECIFICATION Xenon Lamp 180 W Color temperature 6 000 K Life cyde of the lamp 500 h Light output Regulation Counter for operating hours Front display Replacement indicator Front display 686 00200 Spare lamp Xenon 180 W 402 11300 Light guide 4 8 mm length 2 3 m 402 11100 Light guide 4 8 mm length 3 0 m High performance light guide 402 1410 LG 310 W length 2 3 m High performance light guide 402 11510 LG 310 W length 3 0 m KE 363159 Potential equalization cable 1 m MS LH LIGHT SOURCE Illumination SS The light source MS LH provides halogen light at a lamp output of 250 W The extremely high luminous efficiency which is unusual for 250 W light sources is obtained by excellent tuning Consistent Light Quality GH CG C ol The light source MS LH is designed with a built in 250 W halogen spare light bulb In case of a lamp defect this allows to proceed with the endoscopic intervention Intended Use SS The light source MS LH provides illumination for fiberoptic endoscopy to gastroenterological and urolog
15. h on the backside Moir Function Allows to use flexible Fibrescopes Freeze and Screen Splitting optional MS V allows controlled by a footswitch freeze and screen splitting on the monitor for detailed comparison GENERAL 670 15000 MS V PAL 100 230 V 670 16000 MS V NTSC 100 230 V 670 15010 MS V PAL 100 230 V 670 16010 MS V NTSC 100 230 V Fuse 100 120 V 2 x T 2 0 AL 250 V IEC 127 Fuse 200 240 V 2 x T 1 0 AL 250 V IEC 127 with potential equalization connection lt Dimension w h d 380 x 70 x 340 mm MS V S VHS cable Bl Power cable E BNC cable Bl User manual Bl RGB cable MS V Standard Version E 2 x composit BNC B 2x Y C S VHS Bl x remote MS V Freeze Version Additional mx RGB E x foot pedal for freeze connector SPECIFICATION COD Camera _ _ _ 768 494 410 000 pixels 752 x 582 440 000 pixels Automatic control CCD Camera Hoad 9852 250 g with cable Head button selectable W B or Print or Window f 16 34 mm 470 28000 C mount Video Camera Lens f 18 mm 470 23400 C mount circular frame picture f 22 mm 470 27400 C mount limited frame picture f 25 mm 470 24400 C mount full frame picture f 30 mm 470 25400 C mount full frame picture f 40 mm 470 26400 C mount full frame picture Urology Video Camera Lens 90 f 18 mm 470 30000 C mount circular frame
16. ical cavities hollow organs and canals Lamp Quick Exchanger eee Can easiliy done by side drawer G D Order No 682 00010 Lamp Exchange Drawer on the side GENERAL 682 00010 MS LH Power supply 100 120 VAC 200 230 VAC Safety class with potential equalization connection T Dimension w h d 350 x 145 x 400 mm MS LH IB Power cable E User manual E 2 spare lamps 250 W Halogen lll 2 spare fuses SPECIFICATION Lamp 2 x Halogen reflect lamp 250 W Colour temperature 3 250 K Life cycle of the lamp 50h Storz compatible Light port 402 11300 Light guide cable 4 8 mm length 2 3 mm 402 11100 Light guide cable 4 8 mm length 3 0 mm 682 00100 Spare lamp 250 W Halogen KE 363159 Cable 1 m for potential equalization HIGH PERFORMANCE LIGHT GUIDE LG 310 W P r oduct Or der No Length Cable AE Adapter endoscope side Al Adapter light source side 402 11410 23m f 4 8 mm AE 2 MGB Wolf AL 3 MGB Wolf 402 11510 3 0m f 4 8 mm AE 2 MGB Wolf AL 3 MGB Wolf Sas 402 11512 3 0 m 0 4 8 mm AE 6 Storz AL 3 MGB Wolf 402 11415 2 3m H 4 8 mm None None 402 11515 3 0 m H 4 8 mm None None We recommend the High Performance Light Guide LG 310 for the use of Xenon light sources At the light entry side con nection cable light source the fibers are melted together resulting in higher resistance towards heat and better transmission compared with a conventi
17. lligent key function Automatic white balance control with OSD On Screen Display Horizontal 750 TV lines Waterproof Camera Head Ergonomic Head Design Intended Use 1 The Endoscopic Camera ML V is intended to attach to standard endoscopes to permit visualization of body cavities hollow organs and canals during endoscopic procedures The endoscopic image can be displayed on any standard medical video monitor The preselected area will always guarantee a brilliant image in combination with different kind of endoscopes beeing used in various endoscopic application 100 coupler optional Order No 670 31430 3 CCD Camera Head With optical zoom f 16 34 mm Order No 470 28000 Camera Head Two Head Buttons A Remote B W B Gain Zoom Digital Zoom Allows to enlarge part of the picture with standard video camera lens GENERAL 670 31430 ML V PAL 100 230 V 670 32430 ML V NTSC 100 230 V Power supply 100 120 VAC 200 230 VAC Safety class with potential equalization T Dimension w h d 380 x 120 x 340 mm Operating humidity 30 5 ML V S VHS cable BNC cable RGB cable Ill Power cable Il User manual ML V x RGB B 2 x Y C S VHS E 2 x composit BNC Bl x remote SPECIFICATION Min of illumination 14 Lux F2 2 gain 15 dB 3000K Font panel 1 50 000 s Automatic 1 60 1 3 Interline CCD x 3 I PAL 752 x 582 hx v x 3 NTSC
18. ndicator unit The connection oft he ELG to the isolating transformer is done simply by plugging into one of the outlets The ELG conforms to the EN 60601 1 and the EC guidlines MDD93 42 EWG Technical Specification Input voltage Output voltage No of outlets Leakage current According to EN 14971 E693 42 EWG Test insulating voltage Construction dass LEN Insulation dass Ambient temperature t Degree of protection mm Dimension I x w x h Order No 670 80200 Isolation Transformer Earth Leakage Guard Typical Application Very high requirements for extremely low lea kage current as well as the reduction of the leakage current of several units combined for the hospital environment Typical applications include installations of an endoscopic set Monitor Light Source Insufflator HF Generator Suction Irrigation unit Recorder Printer Etc MGB 380 Folder Video Systems Video Systems 11 08 2011 Specifications may change without prior notice MGB BERLIN YOUR PARTNER IN ENDOSCOPY AND COMP LETE SYSTEMS FOR THE MINIMAL INVASIVE SURGERY ENT laryngoscopy Bronchoscopy Otoscopy Sinoscopy Electronic Devices for all E Video Cameras BI Monitors i Ii Light Sources lll Shaver Bl Gos Insufflators RF Surgical Device E Pumps www gt aims L E MGB Endoskopische Ger te GmbH Berlin Schwarzschildstrasse 6 12489 Berlin Germany Phone 49 30 63 92 7000 Fax
19. o page 16 MG Order No 670 41100 50 Hz 670 41200 60 Hz Specification m 3 CCD HD Camera 1 3 technology full HDTV 1920 x 1080 BI Full automatic control with digital signal processing Simple and intelligent key function Automatic white balance control with OSD On Screen Display Horizontal 1920 TV lines HD TV Waterproof Camera Head Ergonomic Head Design Digital output 2 x HD SDI 1 x 1 x DVI D Analog output 1 x Composite 1 x S Video Order No Main Connection oO Dimension and Weight Image sensor CD 1 3 Interline CCD 3x 16 9 Dimension w h d 380 x 150 x 340 mm White balance 7 4 kg lll Screen display confirmation Operating Conditions Brightness control Area selecting control Operating temperature 410 C 40 C Enhancement by set button Extent of Delivery Head dimension w h d 35 x 48 x 65 mm ML VHD E Power cable Bl HDMI cable to Head weight 134 g ind cable 3m HD SDI cable Ill S Video cable HOM gene i DVI cable cable 1 5 m 2 Head buttons 1 x selec Button A AWB Interfaces Button B print out Gain ML VHD B x HD SDI Bl x remote Reflection x YPbPr x composite m1 x HDMI E 1 x S Video B x DVI D ML V 3 CCD ENDO CAMERA Specification 3 CCD Camera 1 3 technology Full automatic control with digital signal processing Simple and inte
20. onal light guide Special marking during using the sleeve on the side of the light source will light Conventional Light The fibers are melted together resulting in higher resistance towards heat and more transmission High Performance STANDARD LIGHT GUIDE LG 200 P r oduc t Or der N 0 Lengt h Cable AE Adapter endoscope side AL Adapter light source side 402 11300 23m 4 8 mm AE 2 MGB Wolf AL 3 MGB Wolf 402 11100 3 0 H 4 8 mm AE 2 MGB Wolf AL 3 MGB Wolf 402 11310 23m 4 8 mm 6 Storz AL 7 Storz 402 11305 23m 4 8 mm None None 402 11105 3 0 0 4 8 mm None None 402 11000 1 8 0 3 5 AE 2 MGB Wolf AL 3 MGB Wolf Picture 402 11300 402 11100 402 11010 1 8 m 0 3 5 mm AE 6 Storz AL 7 Storz 402 11005 1 8m 0 3 5 mm None None The Standard Light Guide LG 200 is suitable for Halogen light sources and 180 W Xenon light sources the ends are bonded with special adhesive Our E light guides available with or without adapters G D ADAPTER LIGHT SOURCE SIDE AL Product ADAPTER ENDOSCOPE SIDE AE Product NE m Order No 402 00050 402 00042 402 00033 402 00101 402 00104 402 00102 402 00034 Order No 402 00051 402 00015 402 00005 402 00052 402 00103 MGB Description AL 3 7 AL8 AL9 AL 10 ALT Description AE 2 AE 4 AE 5 AE 6 AE 9 Light Source Side with Connec
21. ortant than any other performance Multi level safety and protection is provided by a combinationof digital control and mechanical technology High or low input gas pressure and accurate 02 gas flow rate are monitored and verified all the time Clear Arrangement MEM od Simple operation either by integrated LCD touch screen or Jog Dial Individual user setting storage allows quick access to the adjustments that best fit your needs Compatibility O0 0 LA i ML GX is compatible to central 02 or different kind of gas bottles Set Pressure K HU L Flow Mode Abdominal Pressure mmHg 0 0 0 Flow Rate Vol 00 uma Gu BACK SE SES Set Pressure mmHg Order No 670 95900 LCD Touch Screen Allows easy operation and individual user setting storage Irrigation included The ML GX has a gas pressure irrigation function which allows liquids irrigation In combination with the MGB Suction Irrigation instrument simple handling and high flow irrigation is guaranteed Heating 02 preheating allows longer surgery GENERAL 670 95900 ML GX Insufflator Power supply 100 240 VAC Safety class with potential equalization connection Dimension w x d x h 380 x 330 x 100 mm without gas bottle Operating temperature 10 C 40 C Operating humidity 30 75 m Silicone heating tube set for insufflation m Disposable filter for insufflation m
22. ransmit high resolution images The magnification is especially adopted for full frame images on 16 9 monitors Standard PAL or NTSC images have less resolution less field of view in horizontal but larger field of view in vertical direction c m Homogenous brightness Some manufacturers of endoscopy video camera systems are using a 4 3 format CCD image sensor or a 16 9 format image sensor with less resolution m Perfect illumination than MGB s ML VHD camera with 1920 H x 1080 V pixels Such cameras using so called pixel shifting or up scaling technology a digital interpolati on process in order to provide HD compatible video signal at output HDMI HD SDI MGB is using a 3 x CCD image sensor with real 1920 H x 1080 V pixel The high end image sensor guarantees brilliant natural HD imaging without any digital manipulation the real natural HD MGB s ML VHD is using high speed digital signal processing DSP This ensures perfect image quality and natural image colors in combination with MGB s HD telescopes and video camera lenses Camera Zoom Telescope m High resolution MGB s ML VHD and optics are perfect adjusted to each other m ow distortion The HD system performs brilliant and precise colors m Brilliant contrast ML VHD Camera head and HD camera zoom lens has optimized weight balanced and ergonomic design for tireless working For HD Video Camera Lens please refer t
23. sion w h d 350 x 400 x 140 mm Operating humidity 30 75 ELICA II S VHS cable BNC cable E Power cable E User manual ELICA Standard Version E 2 x composit BNC B 2x Y C S VHS B 1 remote Additional x foot pedal for freeze connector ELICA II Freeze Version SPECIFICATION 768 x 494 410 000 pixels 752 x 582 440 000 pixels Automatic control SE 250 0 with cable ou W B or Print or Sharp Light guide port x universal light guide port 1 x MGB Wolf Z00M f 16 34 mm 470 28000 mount Video Camera Lens 470 23400 C mount circular frame picture f 22 mm 470 27400 C mount limited frame picture f 25 mm 470 24400 C mount full frame picture f 30 mm 470 25400 C mount full frame picture f 40 mm 470 26400 C mount full frame picture Hee Urology Video Camera Lens 90 f 18 mm C mount circular frame picture co E 470 30000 FENCER THE COMPLETE LAPAROSCOPIC UNIT Pm anny Ps Lee 1 lan la CATION c INSUFFLADON IX AN l B a 42 e LU 4 97 99 gt V Gas Insufflator The 30 Insufflation part in FENCER is equipped with a precise electronical control for an optimal intra abdominal working pressure This allows exact working Three selectable Flow rates of 1 5 8 and 30 l min are available for the exact control of the Insufflator High Resolution Camera by Digital Controlling
24. tion MGB Wolf Storz Aesculap Olympus ACMI Olympus ACMI Pentax Solos Light Source Side with Connection MGB Wolf MGB old MGB telescopes MGB Storz Olympus Aesculap WISAP ACMI CIRCON ME GX INSUFFLATOR USED GAS JL K rr d AL FLOW Specification eee Up to user s choice operating in continuous or intermittent mode ensures suitability for any endoscopic application High Safety GO C 1 L7 l 7 Safety is more important than any other performance Multi level safety and protection is provided by a combination of digital control and mechanical technology High or low input gas pressure and accurate 02 gas flow rate are monitored and verified all the time Compatibility 2 2j 4 L 60 ME GX is compatible to central 02 or different kind of gas bottles Superior Price Performance Ratio Pewee 0 Cv 5 5 2 This device covers all the basic needs for Laparoscopic procedures while it is available for a very attractive price mm NEN ABDOMINAL PRESSURE INSUFFLATION D gt USED GAS Bc ABDOMINAL PRESSURE TM 901 OQ 12 d Easy operation as you are used rey v y Wi to from our ML G FLOW RATE LI Li Lj INSUFFLATION GENERAL 670 95700 ME GX Insufflator Power supply 100 240 VAC Safety class with potential equalization connection
25. ttle 225 mm x180 mm Stable Construction O hw Example Laparoscopy Load Capacity EB Monitor 35 kg Light source Camera 20 kg Insufflator 20 kg HE Generator or Suction Irrigation unit 20 kg Recorder Printer 20 kg D isolation Transformer 35 kg different heights Depot for Suction Irrigation bottle Depot for gas bottles Handle for Moving Controllable positioning and moving of Endo Cart Special Tray for Keyboard Pull out tray for keyboard and storage Lockable Drawer Large sliding drawer inside depth 100 mm for storage of documents and camera ISOLATION TRANSFORMER Isolation Transformer I Special isolating transformer for medical application in an attractive white finish aluminum enclosure The power entry module contains a power switch green LED when line filter for medical use and dual current limiting fuses Double insulated windings ensure a galvanic physical separation between input and output as well as holding the leakage current below the stipulated maximum value Farth Leakage Guard GH CG C The Earth Leakage Guard ELG controls the dielectric resistance between the phase conductor against ground Due to the galvanic separation caused by the isolating transformer the monitoring of the IT system is absent The Earth Leakage Guard ELG eliminatesthis securitiy vulnerability The Earth Leakage Guard ELG is a separate monitor and i

Download Pdf Manuals

image

Related Search

Related Contents

2 ALL A2 - Relazione impianto elettrico_web  User Manual UMI.A2M.V3.3.pub - iCar-Link  Manuale di Istruzioni CDP-102 e 202 Lettori di dischi  取扱説明書 (お客様へ)  Philips hair clipper QC5130  Provincia di Barletta Andria Trani SCHEMA DI DOCUMENTO  

Copyright © All rights reserved.
Failed to retrieve file