1. Q e ele aldehydes 887 i e Permanent action of the substance does not cause damage through 30 days The material is ery good very amp able to be resistant through years Continuous action of the substance causes insignificant and partly reversible damage good to limited through the period of 7 30 days e g puffing up softening reduced mechanical durability discolouring The material should not have the continuous contact with the substance The immediate limited occurrence of damage is possible e g the loss of mechanical durability deformation discolouring bursting dissolving 57 Plastics DANGER For centrifuging infectious materials it is necessary to use hermetically closed buckets in order to prevent they migration into the centrifuge Rotors buckets and round carriers can be sterilized in autoclave with temperature 121 124 C and pressure 215 kPa during 20 min In the centrifuge disinfectants and cleaning agents generally used in medical care should be used e g Aerodesina 2000 Lysoformin 3000 Melseptol Melsept SF Sanepidex Cutasept F Additional accessories can be sterilized using autoclave depending on material that they are made of See table STERILIZATION User is r
2. N N NJ Ww N N N N N N N N gt H gt A N O N WO MED INSTRUMENTS Product Laboratory centrifuge Model MPW 260 Jd onthe basis of Non classified to list A or B and no the Directive 98 79 EC self testing Product complies with the requirements PN EN 61010 1 2011 PN EN 61010 2 020 2008 Directive 2004 108 WE EMC standard PN EN ISO 15223 1 2012 MPW MED INSTRUMENTS C2t PREZES ZARZADU ite SPOLDZIELNIA PRACY Wojciel dri Warsaw 46 Boremlowska Street ojsz ewski ig v Quality policy in line with ISO 9001 2008 Certifying authority MPW MED INSTRUMENTS SPOEDZIZLNIA PRACY w Warszawie DECLARATION OF CONFORMITY Warsaw 13 11 2014 7 7 P Bp I A 1 p f 1 _ _ 1 1 i j f M MED INSTRUMENTS Product Refrigerated laboratory centrifuge Model MPW 260R Product classification on the basis of classifiec or B and for the Directive 98 7 self testing Directive 2004 108 WE EMC standard PN EN ISO 15223 1 2012 A PREZES ZKRBADU MPW MED I
3. _ o 0 tee E 7 gt um 4 temperature delay time delay zone mark of assigning of the centrifuging time 18 Centrifugation drop down list i temporairly disabled E disabled option drop down list active option drop down list 6 3 Centrifuging notes Connect the centrifuge the mains master switch on left side of the centrifuge Open the cover of the centrifuge by pressing the COVER key Prior to putting the rotor one has to check if the rotating chamber is free of impurities e g such as dust glass splinters residues of fluids that must be taken away One shall fit the rotor on the motor shaft driving it home on the cone Fitting the rotor too shallow will result in lack of identification of the rotor after start of the centrifuge displaying the error message and stopping the centrifuge Screw in the bolt for fixing the rotor clockwise and screw it tightly home with the supplied spanner for the rotor Swing out rotors have to be provided with the buckets all seats One should remember that every buckets swings individually Bucket suspension studs should be lubricated periodically with petroleum jelly In case of rotors designed with the cover they must not be used without it Rotor covers must be closed exactly Rotor covers ensure smaller drags of the rotors proper setting of the test tubes and a
4. SCREENIMODES SCREEN SAVER E e HERR 45 46 355 TEMPERATURE OPESET od qu to ova Desa 46 NL SB I RR M M 46 9 7 TOTAL WORKING TIME 47 ROTAT UY Pee d UA E D EDU qc 48 OS SOUNDS UE 48 S WEB ERROR CODE 49 SN EAGTORY AE E 49 9 12 DSERCHARACTERISTICS ACCELE DECEBL cot a e ee ern Neto a be lutea e beide e vui luba dto cu PR 50 9 Sa ROTOR RUNTIME a es DS M Mer MAS o Er AM EU 54 SN CYCLES HISTORY T 54 SUIS MANUFACTURER S DETA o e uon eame DA 54 E codec ane we I T A E S E E E T E 55 10 41 CLEANING OF THE CENTRIFUGE ooie EA a R aa R 55 10 2 MAINTENANCE OF CENTRIFUGE ELEMENTS cccccceccccecccccccccececcececcececcecsceecececceaeecsaceceaeeseaeecseeceseeseaeececee
5. DO WYCZERPANIA ZAPASOW Round carrier O 13 3mm SELL OUT Wirnik k towy 10 10ml 17x75mm z hermetycznie uszczelniong pokryw kat 30 Angle rotor 10 x 10ml O 17x75mm with Hermetically Sealed Lid angle 30 max RPM 14 000 15558 xg max 7 1 Wirnik k towy 4 x 8 x 0 2ml PCR z hermetycznie pokryw kat 45 Angle rotor 4 x 8 x 0 2ml PCR strip tubes with Hermetically Sealed Lid angle 45 max RPM 14 000 RCF 15339xg 7 0 Wirnik k towy 18 x 2ml na prob wki z filtrem z hermetycznie uszczelniong pokryw kat 45 Angle rotor 18 x 2ml for tubes with filter with Hermetically Sealed Lid angle 45 max RPM 14 000 maxRCF 18187xg Rmax 8 3cm Wktadka redukcyjna na prob wke 0 5ml 8mm Round carrier for 0 5ml tube O 8 0mm Wktadka redukcyjna na prob wke 0 4ml 5 8mm Round carrier for 0 4ml tube 5 8mm Wktadka redukcyjna prob wke 0 2ml 6 2mm Round carrier for 0 2ml tube 6 2mm 15011 15128 15127 15124 15125 15011 15128 15127 15124 15125 15048 15050 15053 15118 15119 15119 15053 15054 15120 15419 15054 15120 15419 15121 15122 15130 15127 15124 15125 Wirnik 4 x 100ml komplet 2 pojemnikami 13719 30 11718C Angle rotor 4 x 100ml complete with buckets 13719 angle 30 max RPM 6 300 5014 R
6. adie wl 17 Sic DISPLAY 18 enc ME CENTRIFUGING NOTE NER 19 6 4 SETTING UP RPM RCF TIME TEMPERATURE eran ena n na se naa orna Supra 20 6S USER PROGRAMS ETT UU TT P 22 6 6 PROGRAMS WITH USER CHARACTERISTICS kat Ae eoo ei Forse Gs 24 ON RS A 24 lt T 25 6 9 TERMINATING CENTRIFUGATION icu uad dedo da eet etes usta ev a ee E ari 25 7 TEMPERATURE CONTROL gU vea ERI Vea ends Fa SE Pea E Eae FER RR TA ERI 26 7 1 INITIAL COOLING R RH OR HEATING RH WITH nnne nennen nnn nnn nnn nnns 26 7 2 INITIAL COOLING R RH OR HEATING RH WITHOUT CENTRIFUGING THERMAL 27 7 3 COOLING R RH OR HEATING RH IN START DELAY OF TEMPERATURE 27 7 4 COOLING R RH OR HEATING RH IN SHORT MODE 27 7 5 COOLING NOTES 28 8 PARA
7. With A Y 4 keys mark symbol Press SET ROTOR VASO VELOC FCR RMA RMIN With A Y gt keys select rotor number Confirm by pressing SET Cnoo p CR COFOCOCI 24 Centrifugation 6 8 SHORT mode SHORT mode In SHORT mode the centrifuge is working as long as SHORT key is pressed or when set time is over 6 9 Terminating centrifugation mE STOPPING CENTRIFUGATION CYCLE NE When preselected time is reched centrifugation will end automatically Pressing STOP for the first time will stop centrifuging with the charasteristic set in loaded program Confirm message by pressing STOP lub SET Pressing STOP second time will stop centrifuging with the fastest characteristic 25 7 Temperature control MPW 260R RH only Centrifuge is equipped with ecological refrigerating system with temperature control During centrifugation there may appear differences in temperature on the display and temperature of the samples in the rotor It depends on thermal conductivity of the rotor and samples and centrifugation time Exemplary change of TEMP setting dud PROG 04 131 LT PROG 000 33 48 13 Press SET to enter edit mode With A V b keys mark TEMP fold blinking Press SET Set demanded value by pressing V Confirm set value by pressing SET Leave edit mode by pressing BACK When chamber is being cooled or heated 1 s
8. 300 200
9. Centrifuging process will start when preselected temperature is reached P How to enable run START DELAY OF TEMPERATURE function is described in Parameters of centrifugation chapter 7 4 Cooling R RH or heating RH in SHORT mode Cooling and heating features are avalaible in SHORT mode How to enable run centrifugation in SHORT mode is described in Centrifugation SHORT mode 27 7 5 Cooling R RH notes Centrifuges with cooling MPW 260R RH are equipped with an efficient cooling system It allows obtaining selected temperatures in the chamber even at maximum spin speed or fast obtaining desired temperatures e g 4 C and 36 C Note that time and possibility of obtaining a set temperature is dependent on multiple factors including the power of the cooling system the shape of the rotor the rotor speed ambient temperature etc The accuracy of the temperature stability of 1 Cis determined by the installation place of the temperature sensor 28 Parameters of centrifugation 8 Parameters of centrifugation TIME B TEMP 4 Press SET 0 20 With A V lt P keys select PARAM Press SET to enter PARAM menu 2 PARAM CONFIG p THER CHAME AFTER RUN TART DELAY ACCELERATION DECELERATION RADIUS DENSI g cm THER CHAMB cooling cooling and heating of the chamber OPEN LID AFTER RUN opening cover after centrifuging automatilcally STA
10. 7654 should be used to clear password and remove all locks 43 Setting up locks With keys choose a lock Mark a lock by pressing SET Repeat above steps for desired locks Leave menu with BACK key no programs can be saved acceleration charactristics can SAVE PROGRAM Wis button not be saved deceleration charactristics can not be saved no programs can be deleted DELETE PROGRAM 38 303 button saving programs on position where one was already stored is disabled CHANGE PARAMETERS parameters can not be modified LOAD PROGRAM button programs can be called up START KEY E key centrifugation can not be started Executing disabled procedures is only possible after entering the correct 44 Configuration 9 2 Language Choosing menu language CONFIG LANGUAGE Ce With keys select demanded option Mark selection by pressing SET CONFIG SCREEN With keys select demanded option cue Mark selection by pressing SET MPW 260R RH TIME TEMP 200 19 SF TEMP a2 2 20 C 200 2 00 21 PROG 2 11199 TIME TEMP 2 PROG 21111997 S PARAM M CONFIG p PROG 1111997 RCF only 45 9 4 Screen saver Setting time of screen saver ORCF_AND SPEED D SEED D RCF SCREEN SAVER 15 9 5 Temperature offset MPW 260R RH only Temperature offset D RCF_AND
11. centrifuge No MPW 260 MPW 260R MPW 260RH user manual Cat 20260 R RH ENG MPW MED INSTRUMENTS 2014 04 02 USER MANUAL 208 1 8 SHORT START STOP COVER o e LABORATORY CENTRIFUGE MPW 260 R RH Read this before use MPW MED INSTRUMENTS 46 Boremlowska Street 04 347 Warsaw Poland tel 48 22 610 81 07 service fax 48 22 610 55 36 C mpw mpw pl www mpw pl WARNING SIGNS AND HAZARD ICONS WARNING Warning of potential injury or health risk DANGER Risk of electric shock with potential for severe injury or death as a consequence DANGER Biohazard with potential for risk to health or death as a consequence DANGER Risk of explosion with potential for severe injury or death as a consequence This manual was prepared with special care MPW MED INSTRUMENTS may change the manual at any time and without notice because of improvements typographical errors inaccuracies of current information or improvements to facilities Content 1 TECHNICAL Va cel enu e eu T enu eee cas Cos 5 22 APPHCATIONSE 1 ors 6 3 INSTALLA ION Oed us 7 CENE REY 7 3 2 CURRENT PROTECTION EEE E E EN E E EEEE
12. 15 100 maxRCF 21153xg 8 3cm Wktadka redukcyjna na probowke 0 5ml O 8mm Round carrier for 0 5ml tube O 8 0mm Wktadka redukcyjna na probowke 0 4ml 5 8mm Round carrier for 0 4ml tube 5 8mm Wktadka redukcyjna na probowke 0 2ml O 6 2mm Round carrier for 0 2ml tube 6 2mm Wirnik k towy 36 x 2 1 5ml z hermetycznie uszczelniong pokryw kat 45 Angle rotor 36 x 2 1 5ml with Hermetically Sealed Lid angle 45 max RPM 14 000 max RCF 18187 x g R max 8 3cm Wktadka redukcyjna na prob wke 0 5ml 8mm Round carrier for 0 5ml tube O 8 0mm Wktadka redukcyjna na prob wke 0 4ml 5 8mm Round carrier for 0 4ml tube 5 8mm Wktadka redukcyjna prob wke 0 2ml 6 2mm Round carrier for 0 2ml tube 6 2mm Wirnik k towy 30 x 15 10ml komplet z pojemnikami 13080 17x100 120mm kat 30 Angle rotor 30 x 15 10ml complete with 13080 buckets O 17x100 120mm angle 30 max RPM 4500 maxRCF 3011xg R max 13 3cm Wktadka redukcyjna 13 3mm Round carrier O 13 3mm Wktadka redukcyjna 13 3mm DO WYCZERPANIA ZAPAS W Round carrier 13 3mm SELL OUT Wirnik 30 x 10ml komplet z pojemnikami 13081 17x70 85mm kat 30 Angle rotor 30 x 10ml complete with 13081 buckets 17x70 85mm angle 30 max 4 500 max RCF 3011 max 13 3cm Wktadka redukcyjna O 13 3mm Round carrier O 13 3mm Wktadka redukcyjna O 13 3mm
13. Load opposite buckets with the same accessories Centrifugation of the test tubes of different sizes There is a possibility to centrifuge test tubes of different sizes however it is absolutely necessary in such cases that opposite buckets and round carriers be the same Mass of different containers with test tubes spun at the same time has to be comparable Swing out rotors must be equpiied with all four buckets Lubricate the swing out rotor journal pins F T m 5 a a 2 oi E a a o a ar Pas D EIN CORRECT WRONG It is necessary to insert test tubes symmetrically on the opposite sides FILLING TUBES Fill test tubes outside the centrifuge Please pay special attention to the quality and proper thickness of the glass test tubes walls Those shall be test tubes for centrifuges Fill test tubes outside the centrifuge Lubricate swing out rotor journal pins Use only accessories good condition Protect equipment against corrosion using accurate preventive maintenance HS accessories maintenance HS accessories maintenance Make sure that rubber O rings are lightly coated with silicone grease Use high vacuum grease e g type by LUBRINA HAZARDOUS MATERIALS Infectious materials could be processed in closed buckets only It is not allowed to subject to centrifugation toxic or infectious materials with damaged leak proof seals of the rotor o
14. TIME TEMP NEW load default parameters 00 02100 20 TEMPERATURE 20 C 2 00 1 9 SPEED 2000 RPM TIME 2 min 23 6 6 Programs with user characteristics Loading a modified program in the CURVES fold is signaled by the icon on the main screen TIME amp TEMP airBB aa Icon signals that program with user 1 00 15 acceleration deceleration characteristics are loaded Since curves created by the user are connected with the number of the rotor and the value of speed set loading of a program modified in such a way is subject to certain limitations There is no possibility to change set speed and the rotor number even when the centrifuge is not working It is possible to modify the number of characteristics connected with the program in the PARA fold setting ACEL and within the range 0 9 switches centrifuging process to default characteristics and the limitations are no longer applicable It is not possible to change parameters speed rotor no and others during run when program with user characteristic is loaded Changing these parameters is possible in PARAM ACEL PARAM DECEL 6 7 Choosing rotors There are two ways to select rotor FAST MODE Press SET _ With 117 SPEED RCF TIME B TEMP 39 1588068 23143 aa a2 88 0 2 00 21 Press SET With keys mark choose demanded rotor Confirm by pressing SET Press SET
15. and is categorized in business to business field The icon of the crossed out trash can shows that the device may not be disposed as part of domestic waste The waste disposal guidelines of the individual EC countries might vary If necessary contact your supplier 62 Manufacturer s info 14 Manufacturer s info MPW MED INSTRUMENTS 22 610 56 67 sales department 22 610 81 07 service 22 610 55 36 fax Boremlowska 46 Street http www mpw pl 04 347 Warsaw e mail mpw mpw pl DISTRIBUTOR 63 15 65 Probowka Nazwa MPW Name MPW Tube Wirnik kgtowy 12 x 2 1 5ml z hermetycznie uszczelniong kat 45 Angle rotor 12 x 2 1 5ml with Hermetically Sealed Lid angle 45 max RPM 18 000 max RCF 24269 x g R max 6 7cm Wktadka redukcyjna na prob wke 0 5ml 8mm Round carrier for 0 5ml tube O 8 0mm 15011 15128 15127 Wktadka redukcyjna na prob wke 0 4ml 5 8mm 15124 Round carrier for 0 4ml tube 5 8mm Wktadka redukcyjna na prob wke 0 2ml 6 2mm 15125 Round carrier for 0 2ml tube 6 2mm Wirnik k towy 8 x 50 na prob wki Falcon komplet z pojemnikami 13275 lub 13278 z pokrywka PC 17151 kat 30 Angle rotor 8 x 50ml for Falcon tubes complete with Buckets 13275 or 13278 with PC caps 17151 angle 30 max RPM 5 500 4227 xg R max 12 5cm Wktadka redukcyjna na prob wke 30 25ml 26x102mm Round carrier for
16. 13 3mm SELL OUT 7 Pojemnik na probowke do systemu Arthrex ACP kompletny z pokrywkg Al Bucket for Arthrex ACP system tube complete with cap Al 15048 15050 15053 15118 15119 15119 Pojemnik 50ml prob wke Falcon 30x100mm Bucket 50ml for Falcon tube O 30x100mm Wktadka redukcyjna na prob wke 15ml Falcon 17x120mm Round carrier for 15ml Falcon tube O 17x120mm 15050 Wktadka redukcyjna na prob wke 30 25ml O 26x102mm Round carrier for 30 25ml tube O 26x102mm 15055 15117 Pojemnik 50ml na prob wke Falcon z pokrywk 17151 PC 30x100mm Bucket 50ml for Falcon tube complete with 17151 cap polycarbone Wktadka redukcyjna na prob wke 15ml Falcon O 17x120mm Round carrier for 15ml Falcon tube O 17x120mm Wktadka redukcyjna na prob wke 30 25ml 26x102mm Round carrier for 30 25ml tube O 26x102mm 15055 15117 Wirnik horyzontalny titracyjny komplet 2 2 zawieszkami 13219 na p ytki mikrotitracyjne Microtiter rotor head complete with 2 buckets 13219 for microtiter plates 3000 916 Rmax 9 1cm 15050 12218 15102 Wirnik horyzontalny 4 x 70ml Swing out rotor 4 x 70ml max RPM 4 000 2308 R max 12 9cm 13170 Pojemnik 12 x 5ml na prob wki Monovette 13x81mm Bucket 12 x 5ml for Monovette tubes 13 x 81mm 15120 15419 Pojemnik 70ml 57x66mm na wktadki redukcyjne Bucket 70ml O 57x
17. 15015 Round carrier 5 x 1 5 2 2 2ml for 15123 15015 and 15128 tubes 15128 Podktadka PA pod prob wki z PP 100ml 15040 PA pad under 100ml PP tube Wktadka redukcyjna na prob wki Sterilin 30ml 15055 15056 Round carrier for Sterilin 30ml tube 15222 15223 Wktadka redukcyjna na prob wke 50ml z dnem stozkowym wolnostojaca GREINER 30x103mm max wysoko prob wki 117mm 15051 15052 Round carrier for 50ml conical bottom tube with skirt GREINER 13 1x100mm max height of tube 117mm Pojemnik 100ml O 45x96mm z pokrywka Al 17185 Bucket 100ml 45x96mm with 17185 cap Wktadka redukcyjna na prob wke 15ml Falcon 17x120mm um um um um um um um um um um um um um um gt um um gt 0 N gt gt N N un gt gt N N N N O N A Round carrier 15ml for Falcon tube O 17x120mm Wktadka redukcyjna 5 x 2 7ml 44 5 12 5x100mm 15054 15119 Round carrier 5 x 2 7ml 44 5 12 5x100mm 15120 15419 Wktadka redukcyjna 4 x 7ml na prob wki Vacutainer O 13 1x100mm 15054 15119 Round carrier 4 x 7ml for Vacutainer tubes O 13 1x100mm 15120 15419 Wktadka redukcyjna 4 x 15 10ml na prob wki Vacutainer 16 5x112mm 15046 15048 Round carrier 4 x 15 10ml for Vacutainer tubes 16 5x112mm 15053 15118 14188 Podktadka guma pod pro
18. E E AEA NEE E E EEE ERE NEEE AT E EEN 7 SAEETY NOTES E E EAE E E EN 8 PERSONNE a 8 22 GUARANTEES AN Dauid 8 LOADING THE ROTOR 9 AAS SAFETY HINTS NA 10 Z5 MANTENAN E CONDITIONS craves 11 2 5 SAFETY PRECAUTIONS Ga ws E bs wa und ened a ade anne AE 11 5 OPERATING CER E EAR a SEA PREDA 13 5 15 CENTRIFUGE DESCRIPTION 13 S2 14 5 3 ROTOR AND ACCESSORIES INSTALEA TION 14 bL GONTROMDEVIGE sandur rer eser oe aon uo dessus on der CO adu med DES 15 55 SETUNG PARAMETER S 15 cd dci NIE 15 6 CENTRIFUGATION i Ee Yel bn ce wis ieee Mb 17 CONTROL PANEL T
19. Qo nnnm 4 Date and signature DECLARATION OF DECONTAMINATION In order to protect our employees please fill out the declaration of decontamination completely before sending centrifuge to the manufacturer return 5 Device STYPE serial No 6 Description of decontamination see user Manual 7 Decontamination carried out by 8 Dateandsisnature Centrifuging radius cm 50 45 40 35 30 29 28 2f 26 25 24 23 22 21 20 19 18 17 16 14 13 12 11 10 NOMOGRAM Formula used for calculation of this nomogram 2 R C F 11 18 n 1000 where R C F multiple of gravitational acceleration r centrifuging radius cm n rotational speed r p m 9 gravitational acceleration Example of making use of the nomogram A 14 4 cm B 4600 r p m C 3400 xg RCF m 1000 2 n n T000 R C F x g multiple of gravitational acceleration 100000 50000 40000 30000 20000 15000 10000 8000 6000 5000 4000 3000 2400 2000 1500 1200 1000 800 600 500 400 300 200 150 120 100 O r p m 20000 15000 14000 13000 12000 11000 10000 9000 8000 7000 6000 5000 4500 4000 3500 3000 2500 2000 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400
20. SPEED NORMAL SIZE SPEED 200M gt D gt 200M EFSCREEN SAVER 15 gt TEMP offset 2 C 96 Time date Setting the time and date DATE TIME DD MM VvVvy 55 89 01 2012 04 49 09 EXIT 46 CONFIG SCREEN To activate screen saver setting select screen saver option and press gt With A Y keys select demanded value from 1 to 60 minutes Mark selection by pressing SET CONFIG SCREEN MODE With keys choose TEMP offset Press gt With AV keys choose difference between the set temperature and the temperature which cooling system try to reach CONFIG TIME DATE With keys select demanded option Mark selection by pressing SET With keys select DATE TIME blinking Press SET With lt b keys place demanded value Press SET With A Y keys change selected value Accept changes by pressing SET Repeat above steps for other values Choose EXIT 9 7 Total working time Total working time of centrifuge ger 20M 465 36 WORKING 2666 HOURS EXIT Configuration CONFIG CYCLES In the CYCLES menu the following statistics are displayed total working centrifugation time working cycles counter When the total working time is greater than 2000h the warning splash screen will be displayed every time the centrifuge is switched on In case the centrifuge should be examined by the manufacturer s service Warn
21. TIME TEMP 19 13 5 With 4 keys select CONFIG menu Press SET To navigate in CONFIG use 4 keys To enter CONFIG menu press SET password protection LANGUAGE menu language SCREEN main screen modes TIME DATE time and date settings CYCLES ROTATING TIME BUZZER SENSOR RESET ROT RUNTIME 10 CYCLES 10 last centrifugation cycles history CONTACT US manufacturer s details CURVES user characteristics ACC DEC 42 Configuration 9 1 Password protection Setting up password CONFIG PASSWORD To prevent from an unauthorized use a PASSWORD can be set Note No PASSWORD is set by default The PASSWORD can be set as follows when the rotor is at a standstill Press the 4 keys until PASSWORD blinks Press SET With gt keys set the valid 1000s place OGRAM ARAMETE of the PASSWORD e g 1xxx With keys set correct value Repeat above steps for all places Press SET BRAM As a confirmation repeat instructions EXIT described above When the PASSWORD is set the Key sign is displayed in the CODE zone It is also displayed in the main menu lower right corner of the screen TIME TEMP a3 85 88 16 C 305 16 PARAM p CONFIG TIME H TEMP 4800 2319 D PASSHORD 3 03 16 05 1 Lue 3 305 16 To delete the PASSWORD 0000 must set If the PASSWORD is forgotten the emergency code
22. details MPH 260R 7 5 7 8 Y MPH MED INSTRUMENTS i i 46 BOREMLOHSKA St The list can be scrolled using V keys HHH MPH PL gt MPHaMPH PL SALES DEPOT To exit press SET BACK key 54 Maintenance 10 Maintenance 10 1 Cleaning of the centrifuge For cleaning water with soap or other water soluble mild detergent shall be used One should avoid corrosive and aggressive substances It is prohibited to use alkaline solutions inflammable solvents or agents containing abrasive particles Using wiping cloth remove condensate or residues of the products from the rotor chamber It is recommended to keep the cover opened when the centrifuge does not work in order to expel the moisture In case the user decides to use centrifuge and equipment cleaning methods other than the ones described in this manual the user shall contact the device manufacturer in order to check whether the cleaning method chosen does not damage the device 10 2 Maintenance of centrifuge elements The rotor pins shall be always lubricated with petroleum jelly In this way the uniform deflection of the buckets and quiet centrifuge operation is ensured Cleaning of the accessories In order to ensure safe operation one shall carry out in regular way periodical maintenance of the accessories Rotors buckets and round carriers have to withstand high stresses originating from the centrifugal force Chemical reactio
23. generation of MPW MED INSTRUMENTS laboratory centrifuges is provided with state of the art microprocessor control systems very durable and quiet asynchronous brushless motors and accessories consistent with requirements of the present day user 5 1 Centrifuge description 1 inspection glass 7 mains socket rear wall 2 cover 8 clamp 3 control panel 4 emerengcy cover opening 5 power switch 11 motor axle 6 USB port 13 5 2 Design The centrifuge has rigid self supporting structure Housing was made of sheet aluminium back made of steel sheet Front and cover was made of ABS type plastic Cover is fixed on steel axles of hinges and from the front it is locked with two electromagnetic locks blocking possible opening during centrifugation Rotation chamber casing was made of thick steel sheet The rotation chamber bowl is made of stainless steel sheet Rotors and containers are from aluminium lids from polycarbonate and reductive inserts from the polypropylene 5 3 Rotor and accessories installation Connect the centrifuge to the mains master switch on left side of the centrifuge Open the cover of the centrifuge by pressing the COVER key Prior to putting the rotor in one has to check if the rotating chamber is free of impurities e g such as dust glass splinters residues of fluids that must be taken away One shall fit the rotor on the motor shaft driving it home on the con
24. of controlling centrifuge operation MED INSTRUMENTS MP Centvituge MEW Z260 R 1 TIME TEMP SHORT START STOP COVER 0 OOO Control panel e sew oneee 0 _ ow stor wa r a ow o memes ov oom 7 ornes 1 gt ome 1 the centrifuge is working as long as the key is pressed first time pressing press will make stopping centrifuging with acceleration characteristics set in the current program confirm message with pressing STOP or BACK key second time pressing will make the centrifuging as fast as possible quickest characteristic During setting of the parameters it serves for exiting zones on the primary screen without introducing changes 17 6 2 Display The display is located in the centre of the control panel The main screen variants are presented below MAIN SCREEN RCF 3 2 E sen 326 a8 82 88 1 C MPW 260R RH 19 assigned measured RCF centrifugal force assigned measured TIME centrifuging time assigned measured TEMP assigned measured PROG 11199 rotor no parameters of the centrifuge CONT configurationmenu user curvers 10 19 density gt 1 2 g cm counting time down decreasing E cooling to set temperature E
25. switched off during acceleration or operation of the centrifuge and the error message will be displayed Rotor verification and checking compatibility with loaded progam Directly after starting centrifuging a unit verifies the type of the rotor applied and in the case of its incompatibility with the type indicated in the application or absence of the rotor the spinning process shall be stopped with simultaneous displaying the error message The conformity of the type of the rotor is signalled with a single audible signal Program no 99 can be run without setting rotor but the rotor must be supported by the centrifuge Rest state inspection Opening of the centrifuge s cover is possible only with the rotor in the state of rest When the rotor is being stopped the STOP diode is on and goes off when it is stopped excepting emergency cover opening see p TROUBLESHOOTING Checking of excessive temperature If temperature in rotation chamber exceeds 50 MPW 260 65 MPW 260R RH caused by for example malfunction of cooling system drive will be switched off and error message will be displayed The reboot is only possible after chilling device 15 6 Centrifugation Power switching ON OFF is carried out with master switch situated on the side wall of the centrifuge All settings on the centrifuge are done by means of the control panel 6 1 Control panel The control panel placed on the front casing serves the purpose
26. to setting the characteristics section time only the set TIME value is blinking With UP and DOWN keys one should set the required time value and press the SET key In order to compete the creation of the deceleration curve it is necessary for the speed of the last of programmed sections of the curve to be equal 0 Otherwise the curves wizard will not enable the end of programming it will be impossible to select the EXIT option After programming the section 1 there is a possibility to program the next section number 2 2 SECTION New section programming possible the whole line 2 is blinking Programming as in the case of the section 1 To stop creating the deceleration 1 9 94 19 i466 curve at the stage of two sections it is necessary to set the speed in section 2 to O and press the SET key The maximum speed of the next section of deceleration characteristic is equal to the speed programmed already of the previous section 52 Configuration SECTION New section programming possible the whole line 3 is blinking Programming as in the case of the section 1 To stop creating the deceleration curve at the stage of three sections it is necessary to set the speed in section 3 to 0 and press the SET key 4 SECTION New section programming possible the whole line 4 is blinking Programming as in the case of the section 1 If speed of the last section 0 it is possible to save the created c
27. 1 2ml 15040 Prob wka z polipropylenu 100ml z pokrywk 44 7 47x103 7mm Polypropylene tube 100ml with 44 7 47x103 7mm 15046 Probowka z polipropylenu 14ml z korkiem O 16 8 17 7x106mm Polypropylene tube 14ml with cap O 16 8 17 7x106mm 15048 Probowka z polipropylenu 15ml Nalgene O 16x113mm Polypropylene tube 15ml Nalgene 16x113mm 15050 Prob wka z polipropylenu 15ml z dnem stozkowym O 17 21x120mm Polypropylene tube 15ml with conical bottom O17 21x120mm 15051 Prob wka z polipropylenu 50ml Nalgene Polypropylene tube 50ml Nalgene 28 8x106 7mm 15052 Prob wka z polipropylenu 50ml z dnem sto kowym z pokrywk 29 5 34x117mm Polypropylene tube 50ml with conical bottom with cap O 29 5 34x117mm 15053 Prob wka z polipropylenu 10ml z pokrywk O 16x100mm Polypropylene tube 10ml with cap O 16x100mm 15054 Prob wka z polipropylenu 6ml z pokrywk O 11 7 13 5 95 Polypropylene tube 6ml with cap 11 7 13 5x95mm 15055 Prob wka z polipropylenu 30ml z pokrywk O 24 9x103mm Polypropylene tube 30ml with cap O 24 9 103 15056 Prob wka z poliw glanu 30ml Nalgene z pokrywk 25 5x94mm Policarbonate tube 30ml Nalgene with cap O 25 5 94 15100 Kapilary szklane heparynowane 1 4 x 75mm 37ul Capillary tubes heparinized 1 4 x 75mm 37ul 15102 Ptytka titracyjna 2 pokrywka 85 5x127mm Microtiter plate with cap 85 5x127mm Probowka szklana 100ml 45x100mm Glass tu
28. 260R with cooling MPW 260RH with cooling and heating Its construction ensures easy operation safe work and wide range of applications at laboratories engaged in routine medical analyses biochemical research works etc This centrifuge is not biotight and therefore during centrifugation of preparations requiring biotightness one has to use closed and sealed containers and rotors In the centrifuge it is prohibited to centrifuge caustic inflammable and explosive preparations 3 Installation Open the package Remove box containing the accessories Take out centrifuge from the container Keep the box and packing materials in case of service shipping name qty pcs cat no emergency openingofthecover T1764 3 1 Location The centrifuge shall not be located near source of heat and shall not be subjected to direct sunlight The table for the centrifuge shall be stable and shall have flat levelled table top It is necessary to ensure a safety zone of the minimum 30 cm round the centrifuge from every direction At the change of the place from cold to warm one condensation of water will occur inside the centrifuge It is important then that sufficient time be provided for drying the centrifuge prior to starting the centrifuge again min 4 hours Supply voltage given on the rating plate has to be consistent with local supply voltage MPW MED INSTRUMENTS laboratory centrifuges are 1st safety class devices and they ar
29. 30 25ml tube O 26x102mm Wirnik kgtowy 8 x 50 na prob wki Falcon komplet pojemnikami 13276 kat 30 15055 15117 Angle rotor 8 x 50ml for Falcon tubes complete with Buckets 13276 angle 30 max 5 500 4227 xg R max 12 5cm Wktadka redukcyjna na probowke 14ml 28 5 17x105mm Round carrier for 14ml tube O 28 5 17x105mm Wktadka redukcyjna na prob wke 5ml 28 5 14x92mm Round carrier for 5ml tube O 28 5 14x92mm Wktadka redukcyjna na prob wke 5ml 29 13x85mm 15120 15419 Round carrier for 5ml tube O 29 13x85mm f Wktadka redukcyjna prob wk 30ml 25x100mm 15055 15056 Round carrier for 30ml tube O 25x100mm 15117 15424 Wktadka redukcyjna na prob wk 15ml Falcon O 17x120mm Round carrier for 15ml Falcon tube O 17x120mm Wktadka redukcyjna prob wke 30 25ml O 26x102mm Round carrier for 30 25ml tube O 26x102mm Wirnik k towy 12 x 5ml 12x85mm z hermetycznie uszczelniong pokryw kat 45 Angle rotor 12 x 5ml 12x85mm with HermeticallySealed Lid angle 45 max RPM 14000 max RCF 19064 R max 8 7cm Wirnik 10 x 15 10ml komplet z pojemnikami 13080 17x100 120mm kat 30 Angle rotor 10 x 15 10ml complete with buckets 13080 O 17x100 120mm angle 30 max 6 000 4226 10 5cm Wktadka redukcyjna 13 3mm Round carrier O 13 3mm Wktadka redukcyjna O 13 3mm DO WYCZE
30. 329 kat 45 Angle rotor 4 x 30 25ml complete with buckets 13329 angle 45 max RPM 6 000 maxRCF 4829xg Rmax 12cm Wktadka redukcyjna na prob wke 7ml O 13x100mm Round carrier for 7ml tube O 13 100mm Wktadka redukcyjna na prob wke 15 10ml 17x120mm 15046 15048 Round carrier for 15 10ml tube O 17 120mm 15053 15118 Wirnik 12 x 30 25ml komplet z pojemnikami 13329 kat 30 Angle rotor 12 x 30 25ml complete with buckets 13329 angle 30 max RPM 5 500 2716 R max 12cm Wktadka redukcyjna na prob wke 7ml 13x100mm Round carrier for 7ml tube O 13 100mm Wktadka redukcyjna na prob wke 15 10ml 17x120mm 15046 15048 Round carrier for 15 10ml tube O 17 120mm 15053 15118 Wirnik k towy 10 x 50ml na prob wki Falcon komplet z pojemnikami 13276 kat 30 15054 15119 15054 15119 Angle rotor 10 x 50ml for Falcon tubes complete with buckets 13276 angle 30 max 4 500 maxRCF 2830xg R max 12 5cm Wktadka redukcyjna na prob wke 14ml 28 5 17x105mm Round carrier for 14ml tube O 28 5 17x105mm 15046 Wktadka redukcyjna na prob wke 5ml 28 5 14x92mm Round carrier for 5ml tube O 28 5 14x92mm Wktadka redukcyjna na prob wke 5ml 29 13x85mm 15120 15419 Round carrier for 5ml tube O 29 13x85mm Wktadka redukcyjna prob wk 30ml O 25x100mm 15055 15056 Round carrier for 30ml tube 25 100 15117 15424 Wktadka red
31. 66mm um um um um um gt um um um um um um um um N 0 0 N N N N N o N N o o NJ gt UW UJ I I N N e N Oo A 14169 Wktadka redukcyjna 8 x 4ml 13x81mm Round carrier 8 x 4ml 13x81mm nai 14235 Wktadka redukcyjna 12 x 5ml O 12x75mm Round carrier 12 x 5ml 12 75 is a 14238 Wktadka redukcyjna 7 x 10ml 17 75 niska 15121 Round carrier 7 x 10ml 17x75mm short 14239 Wktadka redukcyjna 7 x 5ml 13 5x75mm niska Round carrier 7 x 5ml 13 5 75 short 14240 Wktadka redukcyjna 9 x 2 1 5ml 11x38 5mm Round carrier 9 x 2 1 5ml 11x38 5mm dcn 14242 Wktadka redukcyjna 12 x 1 2ml prob wki S Monovette 56x66mm niska 15016 Round carrier 12 x 1 2ml for S Monovette tubes O 56x66mm short Wirnik hematokrytowy 24 kapilary 75mm 12300 Hematocrite rotor for 24 capillaries 75mm 15100 max RPM 13 000 maxRCF 16816xg 8 9 16135 Czytnik hematokrytowy ptaski DO WYCZERPANIA ZAPAS W Hematocrite reader flat SELL OUT 16164 Czytnik hematokrytowy okragty Hematocrite reader round Cat PROBOWKI TUBES 15011 Prob wka 2 polipropylenu 2ml 10 8x40mm okragtodenna Polypropylene tube 2ml 10 8x40mm round bottom 15016 Probowka S Monovette 1 2ml S Monovette tube
32. 8 5 14x92mm Round carrier for 5ml tube O 28 5 14x92mm Wktadka redukcyjna na prob wke 5ml 29 13x85mm Round carrier for 5ml tube O 29 13x85mm Wktadka redukcyjna na prob wke 30ml O 25x100mm 15055 15056 Round carrier for 30ml tube O 25x100mm 15117 15424 Wktadka redukcyjna na prob wke 15ml Falcon 17x120mm 15050 15046 15120 15419 um um um um um um um m um Hd um um um um um um um E E E E E O O O O O O O O O lt N O O O O O lt lt UW 6 I I I I UW I I I OW o UW N UW N UW I Oo W O 0 gt Round carrier for 15ml Falcon tube 17x120mm Wktadka redukcyjna na prob wke 30 25ml O 26x102mm 15055 15117 Round carrier for 30 25ml tube 26x102mm Wirnik bebnowy 6 x 20 x 0 4 0 2ml komplet z 6 kasetami 14000 z hermetycznie pokrywa Drum rotor 6 x 20 x 0 4 0 2ml complete with 6 14000 cassetes with Hermetically Sealed Lid max RPM 14 500 maxRCF 16454xg 7 12172C A 15125 Wirnik bebnowy 6 x 10 x 2 1 5ml komplet z 6 kasetami 14002 z hermetycznie uszczelniona pokrywa Drum rotor 6 x 10 x 2 1 5ml complete with 6 14002 cassetes with Hermetically Sealed Lid max RPM 14 500 maxRCF 16454xg Rmax 7cm Wirnik horyzonta
33. ER RUN When centrifuge process is finished cover will be opened automatically When centrifuging is terminated pressing STOP opening cover is possible by pressing COVER B symbol means that OPEN LID AFTER RUN is active STARY DELAY OF TIME 31 With A V keys select START DELAY Press SET Start delay can set from 0 00 01109 59 59 With keys select OF TIME Press SET Press V then select time zone e g 0 00 42 With A V keys set demanded value Confirm by pressing SET TIME LEN a 2 When START DELAY function is activated 2 00 20 Da symbol is visible on the screen symbol informs that time is remaining 4 PARAM p CONFIG START DELAY OF TIME function cannot be run when START DELAY OF TEMP is activated 8 7 Start delay of temperature MPW 260R RH only a Start centrifuging since preselected START DELAY OF TEMP 500 temperature is reached With A V keys select START DELAY Press SET With A V keys select OF TEMP Press SET With lt b keys select temperature zone With A V keys set demanded value TEMP ES When START DELAY OF TEMPERATURE PEED RCF 00 02100 3 C is turned 4 symbol is visible on 715 57 2 00 19 screen 78 SERA blinking symbols means that temperature is increasing PROG a 11459 PARAM CONFIG 4 decreasing When function is active rotor is
34. METERS OF CENTRIFUGATION ccccccccccccccccccccccccccccccccccccccccccccccccccccceccccccccccccccccceccccccecccs 29 8 1 ACCELERATING DECELERATING CHANGING CHARACTERISTICS s ccccsseccccsccecccccececceccenececaucececeucceeaeececaueeseeaes 29 8 22 GRAD MW 30 93 SAMPEE DENSITY E E A A EE EENE A A 30 oL THERMAL CHAMBER vols ned so Sow du dae a ius a 31 85 AUTOMATIC EID OPENINGOS Eve edunt eed a cud aiti de Ov vex e nox 31 eM eed a9 IE SOF TIME 31 6 7 START DELAY TEMPERATURE bacc att uar conn Tom aes 32 S S iO IKE 33 6 9 TEMPORARILY DISABLED FUNCTIONS exte a env avete sesso vc vite Ue n ev LIN 36 Be LO DUNBALANCE cas Stored AL E Leo cre dees dbase 36 PRINTING REPORT reete RO SER e ee cov seta dde equ sun dul sors edet DDR ca UE 37 9 CONFIGURATION sc ea aaa A a 42 PASSWORD PROTECTION 2 551 o2 iate ctun Sie 43 92 45 9 3
35. NSTRUMENTS d SPOLDZIELNIA PRACY mM um Warsaw 46 Boremlowska Street Quality policy in line with ISO 9001 2008 Certifying authority MED INSTRUMENTS SPOLDZIELNIAPRACY w Warszawie DECLARATION OF CONFORMITY Warsaw 13 11 2014 MED INSTRUMENTS DECLARATION OF CONFORMITY Product Refrigerated and heated laboratory centrifuge Model MPW 260RH Product classification on the basis of Non classified to list A or B and not for the Directive 98 7 self testing Directive 2004 108 WE EMC standard PN EN ISO 15223 1 2012 MPW MED INSTRUMENTS ZR PREZES ZARAADU WY SPOLDZIELNIA PRACY Wojcieth Nojszewski Warsaw 46 Boremlowska Street Quality policy in line with ISO 9001 2008 Certifying authority MPW MED INSTRUMENTS SPOEDZIZLNIA PRACY w Warszawie y Warsaw 13 11 2014 Dr uiii dii dm a 1 M D K 4 d f f DECLARATION OF DECONTAMINATION In order to protect our employees please fill out the declaration of decontamination completely before sending centrifuge to the manufacturer repair 1 Device lt lt RR 2 Description of decontamination see user Manual 3 Decontamination carried out by qj J kRkKIJk lqll
36. RPANIA ZAPASOW Round carrier 13 3m SELL OUT Wirnik 10 x 10ml komplet pojemnikami 13081 17x70 85mm kat 30 Angle rotor 10 x 10ml complete with buckets 13081 17x70 85mm angle 30 max RPM 6000 maxRCF 4226 R max 10 5cm Wktadka redukcyjna 13 3mm 15054 15120 Round carrier O 13 3mm 15419 15046 15050 15055 15117 15419 15048 15050 15053 15118 15119 15119 15053 Wktadka redukcyjna 13 3mm DO WYCZERPANIA ZAPAS W 15054 15120 Round carrier O 13 3m SELL OUT 15419 m gt gt gt gt gt gt a gt gt a a E Os A A IE A A A A A AB A A A A A o O O N O O N N N O O O O O N N N gt gt O a CO IE E W I N N N N N W QJ QJ A C C O O o gt oJ gt gt gt gt ES gt IE gt gt IE gt gt gt ES gt gt gt ES A j j P P O O P IA P P n eo N o 0 o o N o N o I gt Wirnik k towy 24 x 2 1 5ml z hermetycznie pokryw kat 45 Angle rotor 24 x 2 1 5ml with Hermetically Sealed Lid angle 45 max RPM
37. RT DELAY starting delayed after pressing START 8 1 Accelerating decelerating changing characteristics ACCELERATION 10 linear accelerating characteristics assigned to every rotor 0 ER CHAMB 9 JECELERAT ION LID AFTER RUN ADIUS ART DELAY mm 2 NSI 97 21 DECELERATION 10 linear decelerating characteristics assigned to every rotor 0 9 29 8 2 Radius FTER RUN y TIME 03 05 00 16 PARAM CONFIG p 2545 8 3 Sample density gt D 5 D FTER RUN Lh carom 21 2 3 25 16 305 16 PARAM CONFIG gt 2379 11211 30 RADIUS mm control of the radius of the rotor within the range from Rmin to Rmax Avalaible values depends on chosen rotor see LIST OF ROTORS fold When radius is changed is activated symbol is visible on the screen Reducing of the rotor radius and the resulting change of displayed RCF value applies until switching off the power supply of the centrifuge or setting the Rmax maximum radius once again loading the program does not change this setting To change the rotor radius select RADIUS mm with P gt keys Press SET Set demanded value by pressing AW Press SET to accept changes DENSI g cm default density is set to 1 2 g cm possible values 1 2 9 9 g cm When density is changed symbol is visible on
38. able CD MPW Editor application FTDI USB drivers name Preparation Connect centrifuge to the PC with the USB cable connection diagram is given below if necessary install FTDI USB drivers for details see attached CD Ensure that virtual serial port COM USB Serial Port settings are set as described below run control panel system device manager Baud rate 9600 Data length 8 Parity none Stop bite 1 Flow control none 37 O Device Manaper EK Action B Floppy disk controllers Floppy disk drives IDE ATAJATAPI controllers 3 8 Imaging devices Device Application Interface COM 1 Properties rales Uu Keyboards TS Mice and other pointing devices General Port Settings Driver Details Power Management L Madems ig Monitors 5 Network adapters Bis persecond by Ports COM amp LPT Communications Port 1 Data bits 8 Communications Port 2 y Printer Port LPT Party None a USB Serial Port 11 M Processors Stop bits 1 48 Sound video and game controllers M System devices Universal Serial Bus controllers control None af Install MPW Editor application Windows delivered on CD Centrifuging and printing report MPW Editor application Choose Jezyk English Choose COM port assigned to the centrifuge i
39. ance Make sure that rubber O rings are lightly coated with silicone grease Use high vacuum grease e g type by LUBRINA 10 3 Sterilization One can use all standard disinfectants The centrifuges and accessories are constructed from various materials and one should to take into account possible variety of materials During sterilization by means of steam one should to consider temperature resistance of individual materials STERILIZATION sterilization radiation B radiation y formalin ethylene oxide ethanol PS SAN PMMA PC PVC POM PE LD PE HD PP Maintenance e may be used Cannot be used Laboratory vessels have to be exactly cleaned and rinsed with the distilled water before the sterilization in the autoclave It is always necessary to remove closures from containers 1 The frequent steam sterilization reduces mechanical durability PC test tubes may become useless 2 Except PVC hoses which are resistant to the steam sterilization in the temperature 121 C Chemical resistance of plastics cyclic alcohols strong or concentrated acids weak or diluted oxidizing substances cyclic hydrocarbons haloid hydrocarbons PS SAN PMMA PC PVC POM PELD PE HD ee PMP ECTFE ETFE PTFE FEP PFA FKM EPDM ve S e ketones
40. be 100ml O 45x100mm Glass tube 50ml O 35x100mm Glass tube 25ml O 25x100mm Glass tube 10ml 16x100mm Glass tube 7ml 12x100mm Glass tube 5ml 12x75mm Polypropylene tube 10ml with cap 17 19x70mm O6x21mm Polypropylene tube 2 2ml with cap for cyto 10 8 x43mm Prob wka z polipropylenu 0 2ml PCR O 6x21mm Polypropylene tube 0 2ml PCR O 6x21mm Prob wka z polipropylenu 0 5ml z pokrywka O 7 8x30mm Polypropylene tube 0 5ml with cap O 7 8x30mm Prob wka z polipropylenu 1 5ml z pokrywka O 10 8x39mm Polypropylene tube 1 5ml with cap 10 8x39mm Prob wki z polipropylenu PCR szeregowe 8 x 0 2ml z odrebnymi pokrywkami w szeregu Prob wka z polipropylenu 0 4ml z pokrywk 5 7x46mm Polypropylene tube 0 4ml with cap 5 7x46mm O 6x21mm Polypropylene PCR stripe 8x0 2ml O 6x21mm Pojemnik Sterilin z polistyrenu 30ml z pokrywka 31x94mm Sterilin polystyrene test tube 30ml with cap 31x94mm Pojemnik Sterilin z polipropylenu 30ml z pokrywka O 31x94mm Sterilin polypropylene test tube 30ml with cap O31x94mm Prob wka z polipropylenu 5ml z korkiem O 12x85mm Polypropylene tube 5ml O12x85mm with cap Prob wka z polipropylenu 30ml z pokrywka O 25 5x94mm Polypropylene tube 30ml with cap O 25 5x94mm um um gt gt um um um gt um um gt gt um um um um um um P B NJ NJ
41. bowki szklane 100 50 30 25ml 15052 15115 Pad rubber under 100 50 30 25ml glass tubes 15116 15117 Wktadka redukcyjna na prob wke 50ml Falcon 30x120mm lub Nalgene komplet z gumow podktadka 14188 Round carrier 50ml for Falcon tube O 30 x120mm or Nalgene complete with 14189C 15051 15052 rubber pad 14188 Wktadka redukcyjna 30 25ml 25 5x102mm komplet z gumowa podktadka 14188 Round carrier 30 25ml O 25 5 x100mm complete with rubber pad 14188 14192C Wktadka redukcyjna 50ml 35x100mm komplet z gumowa podktadka 14188 15116 Round carrier 50ml 35 100 complete with rubber pad 14188 Wktadka redukcyjna 5 x 1 5 2 2 2ml na prob wki 15123 15015 i 15128 15123 15015 Round carrier 5 x 1 5 2 2 2ml for 15123 15015 and 15128 tubes 15128 Podktadka PA pod prob wki z PP 100ml 15040 PA pad under 100ml PP tube 14190C 15055 15056 15117 Wkfadka redukcyjna na prob wke 50ml z dnem sto kowym wolnostoj ca GREINER 30x103mm max wysoko prob wki 117mm 15055 15056 Round carrier for 50ml conical bottom tube with skirt GREINER 15222 15223 13 1x100mm max height of tube 117mm Zawieszka 2 x 15ml na prob wki Falcon kompletna z pojemnikami 13080 O 17x100 120mm Hanger 2 x 15ml for Falcon tube complete with buckets 13080 O 17x100 120mm Wktadka redukcyjna 13 3mm Round carrier O 13 3mm Wktadka redukcyjna 13 3mm DO WYCZERPANIA ZAPAS W Round carrier O
42. carrier 13 3mm SELL OUT Wirnik 12 x 10ml komplet pojemnikami 13081 17x70 85mm kat 30 Angle rotor 12 x 15 10ml complete with buckets 13080 O 17x100 120mm angle 30 max RPM 5500 max 4058 x g R max 12cm 15119 14083 15119 11740C B 14082 Wktadka redukcyjna 13 3mm 15054 15120 Round carrier O 13 3mm 15419 Wktadka redukcyjna 13 3mm DO WYCZERPANIA ZAPAS W 15054 15120 Round carrier O 13 3mm SELL OUT 15419 14083 Wirnik 8 x 15 10ml komplet z pojemnikami 13080 17x100 120mm kat 30 Angle rotor 8 x 15 10ml complete with buckets 13080 O 17x100 120mm angle 30 15048 15050 max RPM 6 000 maxRCF 4226xg R max 10 5cm 15053 15118 14082 Wktadka redukcyjna 13 3mm 15119 Round carrier O 13 3mm T Wktadka redukcyjna 13 3mm DO WYCZERPANIA ZAPAS W Round carrier 13 3mm SELL OUT Wirnik 8 x 10ml komplet z pojemnikami 13081 17x70 85mm kat 30 Angle rotor 8 x 10ml complete with buckets 13081 O 17x70 85mm angle 30 max RPM 6000 maxRCF 4226xg 10 5cm 15053 Wktadka redukcyjna O 13 3mm 15054 15120 Round carrier O 13 3mm 15419 11741C A 11741C B 14082 Wktadka redukcyjna 13 3mm DO WYCZERPANIA ZAPAS W Round carrier O 13 3mm SELL OUT 15054 15120 15419 14083 Wirnik 4 x 30 25ml komplet 2 pojemnikami 13
43. ceaeess 55 AES STERILIZATION T M 56 104 CHEMICAIGRESIS LANGE CROCO P O 58 Ti TROUBLESHOOTING yid veredas a a eve gos ves e vb eeu e eaa Ud E Ive OU EVEN 59 IZ GUARANTEE UN Eee ENS su ES Repas E does d beoe 61 a E AMI EM A M I I II IEEE D D A UE 62 14 MANUFACTURERS INFO rb E ES RUE raaes ata daa Pee sa ze VERS 63 IS ANNEXES Gnd eM II M P dI M EI MM D d 65 OPTIONAL ACCESSORIES STATEMENT OF CONFORMITY DECLARATION OF DECONTAMINATION REPAIR DECLARATION OF DECONTAMINATION RETURN CONVERSION TABLE FOR NOMOGRAM Technical specification 1 Technical specification 46 Boremlowska Street 04 347 Warsaw Poland 260 MPW 260R MPW 260RH cooingmedium R507 CFC HCFCfre Vv 500 ml 90 18000 rpm step 1 rpm 24270 x g step 1 8800 Nm running time 00 00 01 99 59 59 hours min sec step 15 time counting since start button is pressed since preselected speed is reached short time operation mode SHORT yes continuous operation mode HOLD yes 99 1 2 292 O K adjustable temperature 20 40 20 55 step 1 C step 1 C initial cooling heating guaranteed temperature wi
44. don the programming with UP DOWN keys choose the EXIT option it will blink and save press the SET only the acceleration characteristics of 3 section with TIME SPEED parameters described in the line 1 2 and 3 Repeated attempt to program already programmed sections of the acceleration characteristics will cause beginning of programming of the whole acceleration characteristics once again with settings of the program loaded to edition 51 Deceleration characteristic CONFIG CURVES DECEL After choosing CONFIG gt CURVES gt DECEL the window of the characteristics wizard will be displayed Default deceleration characteristics connected with the loaded program will be displayed on the screen Creating of deceleration characteristics takes place a little differently than acceleration characteristics NO TIME SPEED EN momen eni total acceleration time DEC 168 EXIT 8 88 11 DEC 11 characteristic s no 10 19 In the first moment the EXIT field is marked the message is blinking Pressing the SET key will cause returning to the CONFIG CURVES fold without making changes in the deceleration characteristics 1 SECTION To edit the deceleration characteristics one should mark the section of characteristics with UP or DOWN key the whole TIME SPEED line will begin to blink at this stage it is only one section with the number 1 and then press the SET key The device will proceed
45. e Fitting the rotor too shallow will result in lack of identification of the rotor after start of the centrifuge displaying the error message and stopping the centrifuge Screw in the bolt for fixing the rotor clockwise and screw it tightly home with the supplied spanner for the rotor Swing out rotors have to be provided with the buckets in all seats One should remember that every buckets swings individually Bucket suspension studs should be lubricated periodically with petroleum jelly In case of rotors designed with the cover they must be used without it Rotor covers must be closed exactly Rotor covers ensure smaller drags of the rotors proper setting of the test tubes and airtight sealing should use only buckets intended for selected types of the rotor Fill test tubes outside the centrifuge Put on or screw the caps on vessels and rotors if applicable n case of centrifuging in an angle rotor test tubes buckets have to be filled properly in order to prevent from pouring fluids during centrifuging Centrifuge will tolerate small weight differences occurring during loading of rotors However it is recommended to equalize vessels loads as much as possible in order to ensure minimal vibrations during operation When the centrifuge is started with large imbalance the unbalance control system will switch off the drive system and error signal will be transmitted On the monitoring panel err
46. e provided with the three core cable with the plug resistant to dynamic loadings Mains socket shall be provided with the safety pin It is recommended to install emergency cut out that shall be located far from the centrifuge near the exit or beyond the room Before switching on check whether the centrifuge is connected to power supply correctly 3 2 Current protection The centrifuge is equipped with thermal current protection Fuse is situated in the plug in socket unit at back wall of the centrifuge 4 Safety notes 4 1 Operating personnel Laboratory centrifuge can be operated by laboratory personnel after getting acquainted with user manual User manual shall be always held near the centrifuge The centrifuge can not be misused 4 2 Guarantee Guarantee period amounts to minimum 24 months unless otherwise specified in the purchase documents The service life of the centrifuge specified by the manufacturer amounts to 10 years After termination of guarantee period it is necessary to carry out yearly technical inspections of the centrifuge Manufacturer reserves the right to make technical changes in manufactured products Maximum period of storage of not used centrifuge amounts to 1 year After this period a service authorized by manufacturer should carry out technical inspection of the centrifuge Safety notes 4 3 Loading the rotor Fix the rotor on the motor axis firmly Avoid unbalance
47. esponsible for proper disinfections of the centrifuge if some dangerous material was spilled inside or outside of the centrifuge During the above mentioned works one must wear safety gloves 10 4 Chemical resistance One can use all standard disinfectants The centrifuges and accessories are constructed from various materials and one should to take into account possible variety of materials During sterilization by means of steam one should to consider temperature resistance of individual materials DANGER For centrifuging infectious materials it is necessary to use hermetically closed buckets in order to prevent they migration into the centrifuge User is responsible for proper disinfections of the centrifuge if some dangerous material was spilled inside or outside of the centrifuge During the above mentioned works one must wear safety gloves 58 11 Troubleshooting Majority of faults could be removed by switching centrifuge OFF and then ON After switching the centrifuge ON there shall be displayed parameters of the recently implemented program and sound signals comprising four successive tones shall be generated In case of short duration power failure the centrifuge terminates the cycle and displays PROGRAM ERROR code problem question remedy Is supply cable plugged into mains Plugs supply cable correctly Centrifuge does not start Is master switch ON Switch ON power supply Is symbol displayed Wait ti
48. ess 11739 PARAM CONFIG p STOP 6 5 User programs TIME amp TEMP 0 00 20 After switching centrifuge on program that was used in previous session is being loaded 11739 00 00 20 p T I ME B TEMP 3088 9 0 0 20 Modification during run is represented by p PROG symbol amp 11739 0 00 20 22 Centrifugation Choosing program FAST MODE TIME TEMP i 15000 23143 0 200 21 7 C Press SET With AY a gt keys mark PROG fold blinking Press SET Set demanded program by pressing A V Confirm by pressing SET TIME aa 21 Press SET With AY gt keys mark PROG Zone Press SET goa 2 4 With AY keys choose demanded i 2 500 00 02 00 26 3 3 11199 program number marked by gt lt 15666 23143 86 62 66 7 11739 4 Confirm by pressing SET 4666 2379 66 62 66 16 3 3 11211 TIME TEMP ACC ROT With A V keys choose choose one of four 9 o COD SRUE NEM 1199 possibilities LOAD SAVE DELETE NEW a 1 2 PROGRAM 1739 3 E currently loaded program LOAD load program RCF TIME TEMP ACC DEC ROT 6 SAVE save settings as a program SAVE 1199 confirm by selecting YES and pressing VES PROGRAM 1739 SET 1211 TIME TEMP ACC DEC ROT REMOVE 1129 DELETE delete program confirm by VES 1739 selecting YES and pressing SET 1211
49. eys mark SPEED fold blinking ROG d 01 3113 Press SET Choose demanded order of magnitude by pressing gt e g 3000 3 blinking Set demanded value by pressing Repeat above two steps for other orders of magnitude Confirm set value by pressing SET Leave edit mode by pressing BACK Exemplary change of RCF setting TIME TEMP 15 Press SET to enter edit mode an 13 1 19 With A Y gt keys mark fold blinking ROG 11759 PARAM R CONFIG p Press SET Choose demanded order of magnitude by pressing lt P e g 926 9 blinking Set demanded value by pressing A V Repeat above two steps for other orders of magnitude Confirm set value by pressing SET Leave edit mode by pressing BACK 20 Centrifugation When is changed RPM is automatically corrected Exemplary change of TIME setting TIME B 1 1 18 Press SET to enter edit mode E With keys mark TIME fold blinking ROG 11739 01 3113 Press SET Choose demanded order of magnitude by pressing gt e g 13 18 00 1 blinking Set demanded value by pressing A V Repeat above two steps for other orders of magnitude Confirm set value by pressing SET Leave edit mode by pressing BACK Exemplary change of TEMP setting TIME 15 18 00 15 Press SET to enter edit mode 0 13 1 19 W
50. haracteristics by choosing the EXIT option with UP DOWN keys and pressing the SET key Repeated attempt to program already programmed sections of the acceleration characteristics will cause beginning of programming of the whole deceleration characteristics once again with settings of the program loaded to edition TIME SPEED 2118 In case of continuing work with currently loaded 1 LOAD CURVES program with new user characteristics user YES ames 1 should choose YES to load new characteristics 22 53 9 13 Rotor runtime Information about the time of centrifuging and of the quantity of the working cycles of CONFIG ROT RUNTIME each rotor The list can be scrolled using A V keys To exit press SET BACK key ROTOR BUCKET CYCLES T NOM The table also contains icons warning of the duty of execution of validation Re eee T P more than 100 cycles left I l less than 100 cycles left worn rotor 9 14 Cycles history Information concerning parameters of ten CONFIG 10 CYCLES last centrifuging cycles NO_CYCLES 4 Number od cycle can be changed by lt gt DATA TIME keys FOTOR BUCKET SPEED RCF TIME The list can be scrolled using V keys To exit press SET BACK key 9 15 Manufacturer s details Information about the type of the centrifuge CONFIG CONTACT US firmware version and contact
51. ied holders included in the equipment list as well as centrifuge capillaries which diameter length and durability are suitable should be used for spinning in this centrifuge The use of equipment made by other manufacturers should be consulted with the manufacturer of the centrifuge 15 not allowed to lift or shift the centrifuge during operation and rest on it t is nor allowed to stay in the safety zone within 30 cm distance around the centrifuge neither leave within this zone some things e g glass vessels tis not allowed to put any objects on the centrifuge COVER OPENING It isn t allowed to open the cover manually in emergency procedure when rotor is still turning ROTORS It is not allowed to use the rotors and round carriers with signs of corrosion or other mechanical defects It is not allowed to centrifuge highly corrosive substances which may cause material impairment and lower mechanical properties of rotor and round carriers It isn t allowed to use rotors and accessories not admitted by the manufacturer Let to use commercial glass and plastic test tubes which are destined to centrifuging in this laboratory centrifuge One should absolutely not use poor quality elements Cracking of glass vessels and test tubes could result in dangerous vibration of the centrifuge It is not allowed to carry out centrifugation with the rotor caps taken off or not driven tight 12 Operating 5 Operating New
52. ing message can be disabled In order to it follow the instructions below With A Y keys choose WARNING WORKING 2000 HOURS Press SET until Bl disappears Choose EXIT The CYCLE WARNING MESSAGE is turned on by default 47 9 8 Rotating time ELS F1 e Fe NG Ia FROM RUN With keys select demanded option Is COUNTING FROM ASSIGNED SPEED sk COUNTING DOWN Mark selection by pressing SET C COUNTING UP Counting since START key is pressed COUNTING SINCE ROTOR IS IDENTIFIED preselected speed is reached COUNTING FROM ASSIGNED SPEED Presenting mode remaining time COUNTING DOWN left time COUNTING UP 9 9 Sounds Switching ON OFF short audible signals CONFIG SOUNDS accompanying every pressing of any key With A V keys select demanded option Mark selection by pressing SET Warning signals connected with error occurrence cannot be switched off 48 Configuration 9 10 Error codes Information about errors arisen in working of the centrifuge CONFIG SENSOR Intended for service purposes In any moment it is possible to delete the contents of the fold 19 1110707654 5 2 10 For this purpose choose DELETE button INU 8 S TEMP EXIT blinking when marked and confirm by pressing SET key 9 11 Factory settings Restoring factory setings CONFIG RESET All menu settings will be restored to ita
53. irtight sealing should use only buckets intended for selected types of the rotor Fill test tubes outside the centrifuge Put on or screw the caps on vessels and rotors if applicable In case of centrifuging in an angle rotor test tubes buckets have to be filled properly in order to avoid overflows Centrifuge will tolerate small weight differences occurring during loading of rotors However it is recommended to equalize vessels loads as much as possible in order to ensure minimal vibrations during operation When the centrifuge is started with large imbalance the unbalance control system will switch off the drive system and error signal will be transmitted On the monitoring panel error message will be displayed In order to prolong lifetime of the rotor and gaskets rotors shall be lubricated with the maintenance oil while gaskets and threaded parts shall be lubricated with the petroleum jelly 19 replacement of rotor one shall unscrew clamping and then grab the rotor with both hands at opposite sides taking it away from drive shaft by pulling it up 6 4 Setting up RPM RCF TIME temperature On the main screen it is possible to set rotating speed SPEED RPM relative centrifugal force RCF centrifuging time TIME centrifuging temperature TEMP R RH only Exemplary change of SPEED setting eT amp TEMP 1 1 18 Press SET to enter edit mode With gt k
54. ith 4 keys mark TEMP fold blinking ROG 11759 PARAM CONFIG p Press SET Set demanded value by pressing Confirm set value by pressing SET Leave edit mode by pressing BACK Changing parameters during run TIME TEMP There is a possibility to change parameters 3666 1 2 1 19 SPEED TIME TEMP during centrifuging E Such modifications give in currently running PREY 0 1 program Modification during run is represented son m by PROG symbol 21 Detailed description of setting values e g TIME TIME TEMP E 13 Press SET to enter edit mode 7 00 20 With 4 keys mark TIME fold blinking PROG 11739 PARAM CONFIG gt Press SET 2 Choose hours minutes or seconds b lt gt 00 07 00 00 00 07 00 y pressing e l blinking hh mm ss Set demanded value by pressing A V e g Repeat above two steps to set demanded centrifuging time 7 minutes 00 seconds time Confirm set value by pressing SET Leave edit mode by pressing BACK 00 current calue most significant digits symbol shows which orders of magnitude currently shown current value fold HOLD mode continuous operation mode TIME TEMP run centrifuging in HOLD mode set HOLD 13 00 00 00 time P 0 0 20 end centrifuging in HOLD mode pr
55. ll rotor stops and the 5 symbol goes off Centrifuge does not start symbol displayed indications are proof for Close cover symbol must switch off cycle in progress and motor does not start m 15 symbol blinking M cycle in progress press STOP key or wait till cycle ends Unequal rotor load Centrifuge load shall be balanced Centrifuge does not Inclined centrifuge Centrifuge shall be levelled accelerate unbalance error idi SM CO Was centrifuge displaced during Switch ON the centrifuge again after opening and closing the operation cover Check if rotor number in started program is consistent with the After stopping error rotor message is number of the rotor installed in the centrifuge displayed motor error Check rotor status if there are coding magnets inserted Centrifuge does not recognize the rotor Switch the centrifuge OFF then ON and check correctness of and does not stop loaded program symbol on the display is blinking Rotor is still MA Wait for stopping of the rotor and after pressing COVER key single tone is It is not possible to open da 4 displaying of the symbol the cover The sensor is connected correctly and ie Call service the error is still applying Mainsfail re during run The message will be displayed on the Wait for stopping of the rotor clear the error by pressing the display about the decay of tension SET key The overheating
56. lny 4 x 100ml Swing out rotor 4 x 100ml max RPM 4 000 max 2469 13 8cm Pojemnik 100ml 45x89mm Bucket 100ml O 45x89mm Wktadka redukcyjna prob wke 15ml Falcon 17x120mm 12172C B 15011 15128 Round carrier 15ml for Falcon tube O 17x120mm 2097 Wktadka redukcyjna 5 2 7 44 5 12 5x100mm 15054 15119 Round carrier 5 2 7 44 5 12 5x100mm 15120 15419 Wktadka redukcyjna 4 x 7ml prob wki Vacutainer 13 1x100mm 15054 15119 Round carrier 4 x 7ml for Vacutainer tubes O 13 1x100mm 15120 15419 Wktadka redukcyjna 4 x 15 10ml prob wki Vacutainer 16 5x112mm 15046 15048 Round carrier 4 x 15 10ml for Vacutainer tubes 16 5x112mm 15053 15118 Podktadka guma pod probowki szklane 100 50 30 25ml 15052 15115 Pad rubber under 100 50 30 25ml glass tubes 15116 15117 Wktadka redukcyjna prob wke 50ml Falcon 30x120mm lub Nalgene komplet z gumowg podktadka 14188 Round carrier 5Oml for Falcon tube O 30 x120mm or Nalgene complete with rubber pad 14188 Wktadka redukcyjna 30 25ml 25 5x102mm komplet z gumowa podktadka 15055 PED 15056 15117 Round carrier 30 25ml 25 5 x100mm complete with rubber pad 14188 Wktadka redukcyjna 50ml 35x100mm komplet z gumow podktadka 14188 15116 Round carrier 50 35 x100mm complete with rubber pad 14188 Wktadka redukcyjna 5 x 1 5 2 2 2ml na prob wki 15123 15015 i 15128 15123
57. max 11 3cm 14024 Wktadka redukcyjna prob wke 15ml Falcon 17x120mm 15050 Round carrier 15ml for Falcon tube O 17x120mm 14188 Podktadka guma pod probowki szklane 100 50 30 25ml 15052 15115 Pad rubber under 100 50 30 25ml glass tubes 15116 15117 Wktadka redukcyjna prob wke 50ml Falcon 30x120mm lub Nalgene komplet z gumowg podktadkg 14188 15051 15052 Round carrier 50ml for Falcon tube 30 x120mm Nalgene complete with rubber 14188 14190 Wktadka redukcyjna 30 25 25 5 102 komplet z gumow podk adk 14188 15055 Round carrier 30 25 25 5 x100mm complete with rubber pad 14188 15056 15117 Round carrier 50ml O 35 100 complete with rubber pad 14188 14196 Podktadka PA pod prob wki z PP 100ml PA pad under 100ml PP tube Wktadka redukcyjna na prob wke 50ml z dnem stozkowym wolnostojaca GREINER O 30x103mm max wysoko prob wki 117mm Round carrier for 50ml conical bottom tube with skirt GREINER 13 1x100mm max height of tube 117mm Wirnik k towy 12 x 15 10ml komplet z pojemnikami 13080 17x100 120mm kat 30 Angle rotor 12 x 15 10ml complete with buckets 13080 17x100 120mm angle 30 14226 15048 15050 11740C A 15053 15118 max RPM 5 500 maxRCF 4058xg Rmax 12cm 14082 Wktadka redukcyjna 13 3mm Round carrier O 13 3mm Wktadka redukcyjna 13 3mm DO WYCZERPANIA ZAPAS W Round
58. message will b Temperature sensor error mg Switch the centrifuge OFF then ON oo The overheating message will be displayed Error of the the Call service temperature 50 C in the chamber 59 EMERGENCY COVER RELEASE In case of e g mains failure it is possible to open cover manually At first one must be sure that rotor is not in the move use inspection glass On the left hand side of the casing there is a lock Insert emergency opening key 17642 into the lock and turn it counterclockwise The cover can be unlocked and opened only when the rotor is in the rest state 60 Guarantee 12 Guarantee Manufacturer grants to the Buyer the guarantee on conditions specified in the Guarantee Certificate Buyer forfeits the right to guarantee repair when using the device inconsistently with the User manual provisions when damage results from the User s fault Repairs should be carried out in authorized service workshops granted with the MPW Certificate The centrifuge shall be sent to repair after decontaminating disinfections Information about authorized service workshops could be obtained from the Manufacturer 61 13 Disposal When you are disposing the device the respective statutory rules must be observed Pursuant to guideline 2002 96 EC WEEE all devices supplied after August 13 2005 may not be disposed as part of domestic waste The device belongs to 8th group medical devices
59. ne should set the speed value and press the SET key The set speed value is limited by the maximum speed of the rotor connected with the edited program After the end of programming the speed the graphical displaying of the section of all sections will occur TIME SPEED of the user s acceleration characteristics After programming the section 1 there is a possibility to program the next section number 2 50 Configuration 2 SECTION Programming of new section possible the whole line 2 is blinking Programming as in the case of section 1 It is possible also to abandon the programming with UP DOWN keys choose the EXIT option it will blink and save press the SET only the acceleration characteristics of 1 section with TIME SPEED parameters described in the line 1 The minimal speed of the next section of acceleration characteristics is equal to the speed of the already programmed previous section 3 SECTION Programming of new section possible the whole line 3 is blinking Programming as in the case of section 1 It is possible also to abandon the programming with UP DOWN keys choose the EXIT option it will blink and save press the SET only the acceleration characteristics of 2 section with TIME SPEED parameters described in the line 1 and 2 4 SECTION Programming of new section possible the whole line 4 is blinking Programming as in the case of section 1 It is possible also to aban
60. ns as well as corrosion combination of variable pressure and chemical reactions can cause destruction of metals Hard to observe surface cracks increase gradually and weaken material without visible symptoms In case of observation of surface damage crevice or other change as well as the corrosion the given part rotor bucket etc shall be immediately replaced In order to prevent corrosion one has to clean regularly the rotor with the fastening bolt buckets and round carriers Cleaning of the accessories shall be carried out outside of the centrifuge once every week or still better after each use Then those parts shall be dried using soft fabric or in the chamber drier at ca 55 50 Especially prone to the corrosion are parts made of aluminium For cleaning them one should use neutral agent of pH value 6 8 It is forbidden to use alkaline agent of pH gt 8 In this way the useful service life of the device is substantially increased and susceptibility to corrosion is diminished Accurate maintenance increases the service life as well and protects against premature rotor failures Corrosion and damages resulting from insufficient maintenance could not be subject of claims lodged against the manufacturer Lubrication The rotor pins shall be always lubricated with petroleum jelly In this way the uniform deflection of the buckets and quiet centrifuge operation is ensured HS accessories mainten
61. or message will be displayed In order to prolong lifetime of the rotor and gaskets rotors shall be lubricated with the maintenance oil while gaskets and threaded parts shall be lubricated with the petroleum jelly For replacement of the rotor one shall unscrew clamping and then grab the rotor with both hands at opposite sides taking it away from drive shaft by pulling it up 14 Operating 5 4 Control device The microprocessor control unit of the centrifuge ensures broad possibilities of providing realisation and reading of work parameters 5 5 Setting parameters Data setting and read out system forms hermetically closed keyboard with distinctly accessible operation points Easily readable displays signaling individual performed operations facilitate operator s programming and recording of parameters and condition of the centrifuge The centrifuge is provided with the USB interface that enables connection of the centrifuge to external PC unit with the printer and recording the centrifugation parameters 5 6 Safety features Cover lock The centrifuge can be started only with properly closed cover While the cover can be opened only after stopping the rotor In case of emergency opening of the cover during operation the centrifuge will be immediately switched off and the rotor will brake till complete stopping Unbalance detecting When loads of opposite buckets or carriers in rotors are unbalanced the drive will be
62. original values r gt BLL PROGRAMS PARAMETERS AND SATIONS WILL BE GET THE SETTINGS CONTINUE With A V keys select YES or NO Confirm by pressing SET 49 9 12 User characteristics ACCEL DECEL U leration decelerati ser acceleration deceleration CONFIG CURVES characteristics TEMP ACC DEC ROT ae Choose program by pressing keys 300 00 02 00 20 3 3 11195 iis 158808 23143 00 26 00 7 11739 Press SET 4 4000 2379 83 05 00 16 3 3 11211 2 To edit acceleration characteristic choose E TEMP ACC DEC ROT ACCEL by pressing 4 Confirm selection by EXIT CANCEL PROGRAM 2 pressing SET Acceleration characteristic CONFIG CURVES ACCEL After choosing CONFIG gt CURVES gt ACEL the window of the characteristics wizard will be displayed Current acceleration characteristic connected with the loaded program will be displayed on the screen SED In the first moment the EXIT field is marked the message is blinking Pressing the SET key will cause returning to the CONFIG CURVES fold without making changes in the acceleration characteristics 1 SECTION After setting the time the device will proceed to setting the speed of the given section of characteristics only the set value SPEED blinks With UP and DOWN keys o
63. r test tube Proper disinfection procedures have to be carried out when dangerous substances contaminated the centrifuge or its accessories EXPLOSIVE AND COMBUSTIBLE MATERIALS It is not allowed to centrifuge explosive and inflammable materials It is not allowed to centrifuge substances prone to reacting in result of supplying high energy during centrifugation The centrifuge can not be operated in explosion endangered areas It is not allowed to centrifuge materials capable of generating inflammable or explosive mixtures when subjected to air 10 Safety notes 4 5 Maintenance conditions START UP Prior to switching the centrifuge on one shall read carefully all sections of this instruction in order to ensure smooth operation and avoid damages of this device or its accessories In order to protect the centrifuge against unbalance fill in the test tubes up to the same weight TRANSPORTATION Centrifuge must not be transported with the rotor mounted on the shaft GENERAL HINTS One must use original rotors test tubes and spare parts only In case of faulty operation of the centrifuge one shall ask for assistance of service of MPW MED INSTRUMENTS company or its authorized representatives It is not allowed to switch the centrifuge on if it is not installed properly or rotor is not fitted correctly CENTRIFUGES SUBSTANCES It isn t allowed to exceed load limit set by the manufacturer Rotors are intended for fl
64. ressing COVER key after stopping of the rotor One must check if rotor was correctly loaded close the cover and once more start the program In order to protect the rotor against beating in opposite areas of the rotor it has to be provided with identically filled buckets carriers test tubes etc for getting the best balance possible Unbalance causes noise and vibrations during operation and adversely affects power transmission system motor shock absorbers The better balance the smoother will be the centrifuge operation and therefore longer life of usage of the driveline Moreover the ideal separation level is then obtained as already separated constituents would not be moved up by vibration 36 Parameters of centrifugation Emergency stop In any moment of centrifuging it is possible interrupt the process and fast stop the rotor Single time pressing of the STOP key will make centrifuging stop with acceleration characteristics set in the program after pressing the SET or STOP key the device returns to the main screen Pressing and holding it up to 1s will make the centrifuging stop with the most strict characteristic 8 11 Printing report USB When the centrifuging process is finished there is a possibility to obtain report Report can be transferred to PC or printed Devices that offer printing reports are available optionally and they are not delivered with every centrifuge PC USB quantity pcs USB A A c
65. rotating with 2500rpm or lower in order of fast temperature reaching START DELAY OF TEMP function cannot be run when START DELAY OF TIME is activated 32 Parameters of centrifugation 8 8 Errors End of centrifuging manual mode Seer RCE T 280 16 Centrifuging may be stopped at any moment i 2 e 22 with the STOP key The information message will Ok oem be displayed TIME amp TEMP UE iie Stopping centrifuging accordance with the set 1 1 22 time causes generating 3 short audible signals after stopping the rotor and displaying the 11739 SI PARAM CONFIG p Message Additional messages DECAY WHILE In case of power shortage while centrifuging FUGING after repeated switching it on the following error screen will be displayed After operating for 2000 hours after every switching on the centrifuge the error screen is being displayed with information about the necessity to carry out servicing activities After pressing the SET key the device proceeds to the main screen and the device may operate INCORRECT ROTOR NUMBER Identified number of the installed rotor If the ID 117z9 rotor is unknown the sign is being displayed Decelarating After pressing SET or STOP the device returns to the main screen 33 Other messages SPEED OF ROTOR IDENTIFICATION 90 RPM An irregularity in operation
66. s of the centrifuge is signalled by displaying a screen with relevant message a sound signal is also emitted IMBALANCE FAST STOP PLEASE REMOVE CAUSE THEN RESTART NO ROTOR OR IDENTIFICATION SENSOR DAMAGED WRONG DIRECTION OF ROTATION OR UNKNOWN ROTOR PLEASE CLOSE THE LID HAND ROTOR STOPPING Please wait CYCLE S FINISHED 34 Parameters of centrifugation In case of emergency messages centrifuge is not Emergency messages woking properly contact the manufacturer s authorized service center OVERHEATING MOTOR INVERTER ERROR ERROR Error code INVERTER SERIAL BUS ERROR ERROR Error code TEMPERATURE SENSOR ERROR ERROR Error code I2C BUS ERROR ERROR Error code OVERHEATING CENTRIFUGE overheating temp off WORKING 2000 HOURS CALL SERVICE FOR 35 8 9 Temporarily disabled functions Functions written below can be temporarily disabled THERMAL CHAMBER During run ES EN Em EE ES LS 99 DEC 10 19 SPEED TIME TEMP PROG PARAM ACC DEC 10 19 available disabled 8 10 Unbalance The centrifuge is provided with the rotor unbalance sensor and when it will be activated centrifugation process will be stopped through fast braking and at the same time an error message will be displayed Cancellation of this error is possible only through p
67. t will appear after connecting USB cable e g 11 Choose File Edit form 38 Parameters of centrifugation MPW Editor File Language Help Save as dj Print preview Page setup Material Result Operator Accepted by Fill individual folds optionally In the folds with explerary caption Tytut Title there is a possibility to paste form system clipboard any picture e g company logo MPW Editor File Language Help Tytui Title Material Pr bka Sample Result Wynik Result Operator Accepted by Wykona Examinded by Zaakceptowane Aprooved by Date Time Date Raport no n 123456 Choose File Save form Choose Open 39 MPW Editor File Language Help Tytu Title Material Pr bka Sample Result Wynik Result Operator Accepted by Wykonat Examinded by Zaakceptowane Aprooved Date Time Date Raport no 123456 Start centrifuging When centrifuging process is completed report will appear Save report File Save us or print it File Print n order to get another report press New test Connection diagram CENTRIFUGE left bottom corner 40 Parameters of centrifugation e 2 USB cable USB port 41 9 Configuration
68. th max rotor lt 4 C speed E cooling heating without centrifuging no cooling heating with centrifuging no acceleration ACEL 10 linear curves deceleration DECEL 10 linear curves programmable non linear curves acceleration 10 deceleration 10 USB communication yes Electromagnetic compatibility according to PN EN 55011 ambient conditions PN EN 61010 1 p 1 4 1 set up site indoors only ambient temperature 2 40 humidity maximum relative humidity lt 80 excess voltage category PN EN 61010 1 pollution degree PN EN 61010 1 safety area 300 mm dimensions o eee a height H width W depth D with open cover Hoc 56 dB 56 dB weight 230V 28 kg 47 kg 48 5 kg weight 115V 29 5 kg 50 7 kg 52 2 kg factory program program no 99 time and possibility of obtaining a set temperature is dependant on multiple factors including rotor type established RPM ambient temperature accuracy 1 C appropriate for place of temperature sensor Menu languages POLISH ENGLISH GERMAN SPANISH ITALIAN PORTUGUESE RUSSIAN without national characters 2 Application The MPW 260 R RH centrifuges are table top laboratory centrifuge for in vitro diagnostic IVD Devices are used for separation samples taken from people s animal s and plant s components of different densities under the influence of the centrifugal force to provide information about their biological state MPW 260 ventilated MPW
69. the screen Increasing density of the sample above 1 2 g cm and limiting of the maximum speed of centrifuging resulting from it applies until switching off power supply of the centrifuge or setting the device back to 1 2 g cm To change the density select DENSI g cm with AY 4 keys MM Press SET Set demanded value by pressing AW Press SET to accept changes 8 4 Thermal chamber MPW 260R RH only without centrifuging CHAME 68 C LID AFTER RUN amp T DELAY 1 5 GP THER 3 STAR TEMP gm 3 05 00 5 C 3 05 16 Parameters of centrifugation THERMAL CHAMBER With 4 gt keys select THERMAL CHAMBER Press SET to turn on off Set demanded value by pressing V When THERMAL CHAMBER function is activated symbol is visible on the screen Changing temperature from the main screen is not possible Opening cover terminates THERMAL CHAMBER function closing cover back turns it on If THERMAL CHAMBER is turned on in PARAM fold and centrifugation completes THERMAL CHAMBER will activate itself CHAMBER can be only activated when any other program is not running 8 5 Automatic lid opening Automatic lid opening AME AFTER RUN ELAY TIME TEMP 2000 380 136 19 PROG 4 11459 PARAM p CONFIG 4 8 6 Start delay of time Start centrifuging since preselected delay is reached OPEN LID AFT
70. uids of average homogeneous density equal to 1 2 g cm or smaller when centrifugation is carried out at maximum speed When fluids of higher density Shall be used then it is necessary to change density of centrifuges sample in PARAM DENSITY field 4 6 Safety precautions For safety reasons inspections of the centrifuge carried out by the authorized service at least once a year after the period of warranty The reason for more frequent inspections could be corrosion inducing environment Examinations should end with issuing report of validation that checks on the technical state of the laboratory centrifuge It is being recommended to establish document where every repairs and reviews are being registered Both these documents should be stored in the place of use of the centrifuge INSPECTION PROCEDURES CARRIED OUT BY THE OPERATOR Operator has to pay special attention to the fact that the centrifuge parts of key importance due to safety reasons are not damaged This remark is specifically important as for Motor suspension Motor axis concentricity Fixing the pins in the bucket Centrifuge accessories and especially structural changes corrosion preliminary 11 cracks abrasion of metal parts Screw joints Inspection of the rotor assembly Inspection of bioseals of the buckets if such are used Control of execution of the guarantee yearly technical inspection of the centrifuge Only the manufacturer specif
71. ukcyjna na prob wk 15ml Falcon O 17x120mm Round carrier for 15ml Falcon tube O 17x120mm Wktadka redukcyjna na prob wke 30 25ml O 26x102mm Round carrier for 30 25ml tube O 26x102mm 15050 15055 15117 Wirnik 24 x 15 10ml komplet z pojemnikami 13080 17x100 120mm kat 30 15048 15050 Angle rotor 24 x 15 10ml complete with buckets 13080 O 17x100 120mm angle 30 15053 15118 max 5000 RCF 3354xg 12cm Wktadka redukcyjna O 13 3mm Round carrier O 13 3mm Wktadka redukcyjna 13 3mm DO WYCZERPANIA ZAPASOW Round carrier O 13 3mm SELL OUT Wirnik 24 x 10ml komplet pojemnikami 13081 17x70 85mm kat 30 15119 15119 Angle rotor 24 x 15 10ml complete with buckets 13081 17x70 85mm angle 30 15053 max RPM 5000 RCF 3354xg 12cm Wktadka redukcyjna O 13 3mm 15054 15120 Round carrier O 13 3mm 15419 Wktadka redukcyjna 13 3mm DO WYCZERPANIA ZAPASOW 15054 15120 Round carrier O 13 3mm SELL OUT 15419 Wirnik k towy 6 x 50 na prob wki Falcon komplet z pojemnikami 13276 kat 30 Angle rotor 6 x 50ml for Falcon tubes complete with buckets 13276 angle 30 max RPM 6000 max 4427 xg R max 11cm Wktadka redukcyjna na prob wke 14ml 28 5 17x105mm Round carrier for 14ml tube O 28 5 17x105mm Wktadka redukcyjna na prob wke 5ml 2
72. ymbol is visible on the screen blinking 7 1 Initial cooling R RH or heating RH with centrifuging In order to centrifuge preparations of a lowered temperature deposited in the outside refrigerator it is necessary to make initial refrigerating of the chamber the rotor and containers to the set low temperature in order to minimise the difference of temperatures Initial cooling heating function can be activated by executing PROGRAM 99 99 90 2500 temperature Parameters speed 90 2500 RPM time Initial cooling heating functions can be terminated anytime by pressing STOP key 26 Temperature control When cooling function i ive 231 TIME B TEMPER en cooling function is active 5 symbol is visible on the screen blinking 25088 50 00 4 MEHE Jo _ 029 When Initial cooling is active PROG 99 and PROG 99 4114597 PARAM P CONFIG 19 arrows ull are visible blinking in TEMP fold 7 2 Initial cooling R RH or heating RH without centrifuging THERMAL CHAMBER CONFIG gt THERMAL CHAMBER There is possible to run centrifuge in THERMAL CHAMBER mode cooling for R cooling and heating for RH rotor is at standstill How to enable THERMAL CHAMBER is described in Parameters of centrifugation chapter 7 3 Cooling R RH or heating RH in START DELAY OF TEMPERATURE mode mE CONFIG gt START DELAY OF TEMPERATURE

Download Pdf Manuals

image

Related Search

Related Contents

TEFAL GV4210E0 Instruction Manual  Viewsonic PJ678 data projector  Beaphar Geruchbinder Zerstäuber  Philips Coffee jug CRP731  6.5 MB pdf: OS MasterMap Topography Layer user guide and  Guía del usuario de la Impresora/ Copiadora  CPC504 User Manual  平成21年7月10日付け基発0710第1号 - 岡山労働局  Samsung 23'' 5.serija LED monitorius S23A550H Vartotojo vadovas  Gestione Alberghiera tecnologia MIFARE - Articoli comuni  