Home

User Manual - Bel-Art

image

Contents

1. 20 eo cilop t 21 ZT olle DN 22 81 Technical Specifications nnnnnansennannnseerenneneereennnervennenvereennnervennnneereennnserveannsvercennnervennenvercennne 22 8 2 Disposal of the Unit a aenaannnereenneeeeeonnnereenneneeeeonnnereennnneeeenneneevennneeeeennnnervennneeeeennen 24 8 3 Warranty and Disclaimer nnn nnaanansereannnneeeonnnereennnneeeeonenereennnneeeeeneneevennneeeeennnneeeennneeeeennnn 24 84 After sales Service and Customer Assistance eerte 24 gdenceware 1 Safety Advice 1 1 Operation Manual 1 2 This manual contains important safety and operation information You must carefully read understand and follow all the instructions in this manual prior to operating this instrument Keep this manual in a safe place nearby for reference and make it easily available to all users DANGER CAUTION NOTICE Alerts This manual highlights DANGER CAUTION NOTICE alerts to prevent injury or property damage and also to achieve optimum performance of your instrument These alerts are classified into three types in this manual depending on the importance and the risk levels as described below Symbols Meaning Ignoring this alert could cause serious or even fatal injury Ignoring this alert could cause serious injury or property damage NOTICE Ignoring this alert could cause operational problems Ensure to read
2. Operation Manual Cabinet Vacuum Desiccators Models F42400 4001 4101 4021 4121 4011 4111 4031 and 4131 Manual No 942404001 Version 1 0 Sdenceware oo N DWM Table of Contents Safety AQV ernn eeen ae enten 1 Li Operation Mantal zm ande e Ue E EN RU ee en 1 12 DANGER EAUTION NOTIGE Alerts tet t e n lee eed 1 1 3 Danger Alerts xe iet anaes E Ue E EN RR ER ec ege nq 2 TA Ca ti nAlerts ttn ed te He RH ERR ETE RE ERLEBEN Eb anda 2 Product BI TegIejep c 4 23 Introd ction eee e ae needed 4 2 2 Characteristics to RR RR RR ea de eneen 5 2 3 LAY ota SER dee dens 9 Unpacking and InstallatlOn i tette ttr eti RR I ERR Rode ended 11 3 1 Checking Shipment Damage and Unpacking ees 11 3 2 Checking the Contents of the Package teet tttnnnnntterenen 11 3 3 Installation nnn 12 3 3 1 Installation Environment tetti rti i E Re e Rode endete 12 3 3 2 Installation Location etna intend nae 13 Scu 14 4 1 Operation of the 3 Way Valve seen ttetnnnete 14 4 2 Vacuum FormatiOn smerende dte 16 4 3 Multi stacking of the Units nnn aaaanannernannnnersannnsereenneneereennenereennnnervennnneeeeennnervennnneeeennnnsen 17 AA Storage ise tee eb te tie e t RR RH t eM EI EE Te eae 18 MainteriatiCe ciet t bei cd fete i d NE REEE 19 Troubleshooting anssen
3. Scienceware is a registered TM of Bel Art Products PN Bel Art Products assumes no obligation or liability for any advice furnished by it or for results obtained with respect to these products S All such advice is given and accepted at the buyer s risk Wee 2012 Bel Art Products All Rights Reserved
4. Valve Front Nozzle Rear Nozzle Open Closed Closed 14 Closed Closed 15 Sdenceware 4 2 Vacuum Formation The procedures for vacuum formation are as follows 1 When using the unit for drying purposes fill the tray with desiccants and put it inside prior to operation After putting the samples inside the unit firmly close the door by locking the two latches properly You will hear a click sound when the latch is properly engaged Connect the vacuum pump hose to one of the two nozzles of the 3 Way valve After activating the vacuum pump turn the valve handle towards the nozzle to open it and read the vacuum gauge to check whether the vacuum is forming properly When the desired vacuum level is achieved turn the valve handle until it is perpendicular to the nozzle to close it and check the vacuum gauge whether there is any leakage When releasing the vacuum slowly turn the valve handle towards the opposite nozzle to return to the normal pressure Do not impact or drop the unit when a vacuum is formed inside When forming or releasing a vacuum turn the valve handle slowly to avoid rapid pressure change If not the stored samples can be damaged or dispersed 16 Sdenceware When forming a vacuum install a cold trap in front of the vacuum pump Moisture and chemicals from the samples may result in damages to the pump Do not let the body of th
5. e tray Vacuum Gasket Silicone Overall W x D x H 322x285x271 420x397x281 420x397x381 420x397x491 Door Opening 208x238 295x245 295x345 295x445 Dimension W x H s mm Shelf W x D x H omoes 5 28980401 O Desiccant Tray 158x194x24 218x268x268 W x D x H Number of Shelves Shelves 2 4 2 4 3 5 3 6 standard maximu Amber UV Protection Range UV A B C 100 200 450nm Note Applies only to Models F42400 4101 4121 4111 and 4313 23 Sdenceware 8 2 Disposal of the Unit Disposing of the unit must be done in an environmentally responsible way if it has been potentially exposed to bio agents or radioactive samples Failure to follow stringent requirements for appropriate disposal may lead to actions against you and your organization 1 First check with your laboratory or organization to ensure that you are following all the policies and procedures for disposal of laboratory equipments and wastes 2 If not possible contact your local governing body for regulations regarding disposal of laboratory equipments Jeio Tech highly recommends you to find a local service provider that can properly dispose of your unit 8 3 Warranty and Disclaimer See enclosed Warranty Card for conditions and requirements 8 4 After sales Service and Customer Assistance Our after sales service responds to your questions concerning maintenance and repair of your unit as well as spare parts In case o
6. e included in the package If not contact your dealer immediately Quantity Main Body 3 Way Valve F42400 4001 4101 F42400 4021 4121 Port Plug 4011 4111 4031 and 4131 11 Sdenceware Desiccant Tray F42400 4001 4101 Perforated 4021 and 4121 Shelves F42400 4011 4111 4031 and 4131 3 3 Installation 3 3 1 Installation Environment NOTICE Avoid exposure to any heat sources including direct sunlight This unit is designed for indoor use in laboratory environments The conditions for proper installation are as follows Permissible Ambient Temperature 5 to 40 C 41 to 104 F Permissible Relative Humidity Below 80 Permissible Altitude 0 to 2 000 m 6 562 ft 12 3 3 2 Installation Location NOTICE Install the unit on a level surface Install the unit at least 30cm away from other equipment 13 4 Operation Do not form a vacuum when airtight containers are inside the unit Note that this unit cannot be autoclaved When attaching other equipments or additional 3 Way valves after removing the port plugs use proper O rings and nuts for tight sealing e When putting high temperature samples inside the unit cool them thoroughly in advance or make sure that they are not in direct contact with the interior of the unit to avoid interior damage 4 1 Operation of the 3 Way
7. e unit into direct contact with acetone benzene toluene chloroform cresol sodium hydroxide highly concentrated nitric or sulfuric acid acetic acids or strong chlorine based solvents Ensure that the door seal is not damaged by strong acid or base Damaged seal can cause malfunction of the unit When a vacuum is formed inside the unit do not apply excessive force to the 3 way valves the vacuum gauge or any of their vicinities Any damages caused by external forces can cause malfunction of the unit When the unit is not forming a vacuum keep the valve handle perpendicular to the nozzles When relocating the unit use the built in groove handles instead of holding on to other protruded parts such as the vacuum gauge or 3 Way valves 4 3 Multi stacking of the Units These cubic vacuum desiccators are designed to be easily multi stacked together by locking the feet of the unit into the stacking grooves located on the top surface of another unit as shown below 17 Sdenceware 44 Storage If this unit is not used for an extended period of time clean the instrument with soft cloth and store it in dry place after packing it properly 18 Sdenceware 5 Maintenance e If the unit is contaminated wear chemicals resistant gloves before cleaning Regularly check the 3 way valves the vacuum gauge or any of their vic
8. f a warranty claim repair or purchase of replacement parts or in case of queries or other problems please contact your local dealer or Bel Art Products representative 24 Sdenceware lt The contents of this manual can be changed or upgraded without prior notice lt The copyright of this manual is reserved by Bel Art Products 25 aenceware ro TOOLS FOR SCIENCE FROM BEL ART PRODUCTS Addendum to User Manual Accessories Parts List for Cabinet Model Desiccators Bel Art Unit Accessory Used with Accessory No of Measure Description Bel Art Desiccator Number s 942404011 EA Vacuum Gauge F42400 4001 4101 4021 4121 4011 4111 4031 4131 942404010 EA Door Seal F42400 4001 4101 942404009 EA Door Seal F42400 4021 4121 942404008 EA Door Seal F42400 4011 4111 942404007 EA Door Seal F42400 4031 4131 942404006 EA Desiccant Tray F42400 4001 4101 942404005 EA Desiccant Tray F42400 4021 4121 4011 4111 4031 4131 942404004 EA Perforated Shelves F42400 4001 4101 942404003 EA Perforated Shelves F42400 4021 4121 4011 4111 4031 4131 942404002 EA 3 Way Valve For Cabinets F42400 4001 4101 4021 4121 4011 4111 4031 4131 942404001 EA User Manual Cabinet Models F42400 4001 4101 4021 4121 4011 4111 4031 4131 661 Route 23 South Wayne NJ 07470 TEL 1 800 4BEL ART FAX 973 694 7199 e www belart com 10 12
9. ing Efficient Use of the Internal Space Compared to round desiccators cabinet desiccators provide larger usable volumes with the same footprint In addition the internal space can be more efficiently utilized by using the standard perforated shelves designed for efficient airflow Two or three perforated shelves are provided and if needed up to four or six shelves can be used for efficient storage of the samples Refer to Product Checklist or Specifications for details Easy Vacuum Level Checking With a built in vacuum gauge installed on the front door checking the vacuum level is quick and easy Desiccant Tray Sdenceware This unit comes standard with a desiccant tray Desiccants are sold separately Vacuum Gauge Door Door Latch 3 Way Valve Non Slip Feet Groove Handle Valve Port Plug Door Seal Shelf Rail 9 2 Sdenceware 10 Perforated Shelves 11 Desiccant Tray 12 Stacking Groove 13 Air Inlet Outlet Nozzle 10 3 Unpacking and Installation 3 1 Checking Shipment Damage and Unpacking Upon receiving the instrument check to ensure that no damage has occurred during shipment It is important that any damage that occurred during shipment is detected before unpacking If you find such damage the carrier must be notified immediately 3 2 Checking the Contents of the Package After unpacking check to ensure that all the parts and accessories described below ar
10. inities for any damage Regularly check the vacuum seal as well as the surface where the body and the base are in contact and keep them always clean and undamaged Make sure to clean the silicone gasket regularly using diluted neutral detergent For thorough cleaning detach the seal from the lid Do not use chlorine bleach ammonia based cleaners abrasives organic solvents or metal scouring pads when cleaning Use a soft cloth all the time 19 Sdenceware TOOLS FOR SCIENCE FROM BEL ART PRODUCTS 6 Troubleshooting Problem Vacuum Malfunction Cause Contaminated surface between the door and the body Damaged door gasket Unsuitable room temperature Misplaced or damaged 3 way valve Damaged vacuum gauge 20 Corrective Action Thoroughly clean the surface with a soft cloth using diluted neutral detergent Replace the gasket Check the temperature whether it is within the operating range Check whether the valve is properly set If damaged replace it with a new one Replace the gauge Sdenceware 7 Accessories See enclosed addendum for Accessories Parts List 21 8 Appendix 8 1 Technical Specifications Models F42400 4001 4101 4011 4111 4031 4131 Gauge Range 0 0 1 Analog MPa Vacuum Max Permissible 1 33 x 10 1Torr Nozzle Diameter mm Body Shelves PC Polycarbonate 3 Way Valve Latch Desiccant PP Polypropylen
11. periments over extended periods 2 Integral Molding of the Polycarbonate Body Unlike conventional vacuum desiccators the uni body construction is molded as Sdenceware 3 4 5 a single piece except the door for maximum vacuum retention Shock resistant high tensile strength and transparent polycarbonate body provides extreme durability as well as 360 visual observation from outside Viton 3 Way Valve This unit comes standard with a Viton 3 way valve offering consistent and uniform vacuum draw vacuum release or gas exchange without the inconvenience of connecting and disconnecting pump hoses to the unit If needed up to 4 valves can be installed using the built in ports at the base of the unit and the positioning of the valve s can be also easily changed Airtight Door Sealing The door is located in the front for convenient access Equipped with a special door latch which is easily closed at normal pressure and a greaseless vacuum seal using high quality silicon gasket this unit enables airtight sealing between the door and the body and quick vacuum formation Multi stackable Design Sdenceware 6 7 8 The cabinet models come in a variety of capacities to suit the user s needs with the internal volume ranging from 11 liters to 45 liters With the same foot print different models can be stacked together in any convenient fashion allowing for lab space sav
12. the danger and caution alerts in 1 3 and 14 carefully before use 1 3 Danger Alerts Never install or use this unit in explosive atmospheres Never install this unit near to hazardous or flammable substances Never disassemble repair or modify this unit on your own Doing so will void your warranty and may result in injuries or product damages 1 4 Caution Alerts Ignoring the following cautions could cause serious injury or property damage Carefully read all the warning labels before using this unit And do not remove or damage the warning labels Do not move this unit during operation When moving it use the molded in handles Do not use this unit in wet or moist atmosphere or where water leakage is expected Sdenceware Do not use this unit in contaminated atmosphere or where metallic dust exists Do not expose this unit to any heat sources including direct sunlight Do not allow moisture organic solvent dust or corrosive gases to get into this unit Do not use chlorine bleach ammonia based cleaners abrasives ammonia or metal scouring pads Wipe with a soft damped cloth or a sponge soaked in water or diluted neutral detergent Sdenceware 2 Product Description 2 1 Introduction Congratulations of your purchase of our high quality cabinet vacuum desiccator which is specially designed to provide maximum benefit for your investment with respect
13. to performance safety ease of use and durability This unit is a sturdily constructed 360 transparent vacuum desiccator ideal for storing drying cooling and degassing various materials The vacuum environment created by this unit provides a very low humidity contamination free corrosion free and dust free environment ideal for storing moisture sensitive materials such as anhydrides and other hygroscopic compounds as well as materials which are highly reactive with atmosphere removing residual solvents or air bubbles cultivating anaerobic microbes minimizing the reabsorption of humidity and the exposure to air during the drying or the cooling stages of biological medical food materials experiments Sdenceware conducting experiments at low pressure drying at low pressure to minimize the heat effects Currently eight models of cabinet vacuum desiccators are available from Bel Art Products with the internal volume ranging from 11 liters to 45 liters Note that UV blocking models F42400 4101 4121 4111 and 4131 are offered to minimize damages or discoloration of light sensitive samples by using UV blocking resin which completely blocks all ranges of UV and the blue spectrum of the visible light 2 2 Characteristics 1 Outstanding Vacuum Sustainment This unit maintains a 1 Torr 133 Pa vacuum for over 72 hours at room temperature and stays gastight without a vacuum allowing reliable ex