1. confirm questions yes After installation the computer is restarted NetFramework Installation can take up to 10 minutes 3 Next will be install Windowslnstaller 3 It is needed to install the analyzer pressure 4 Now will instal software Analyzer common rail confirm all questions of installer 5 After installation shortcut will be on the desktop Now you can run software description of the buttons is in the picture below 1 Large gauge indicates the current pressure or voltage 2 Knob Interval is used to inflict the measurement interval between measurement samples 3 Knob Select the COM port is used to select the communication port 4 On the graph is plotted the measured pressure the speed setpoint by the interval 5 DEMO button is used to test the possibilities of the program the pressure is simulated by the program it is not received from the port 6 Buttons to choose the type of sensors are used to select the sensor according to his measuring range the cars are used two types of to 1600bar and 1800bar 7 The Clear chart button will clear all chart 8 the Start Stop button starts or stops the program Analizator wysokiego ci nienia Common Rail Ot x Print Info Help Workshop Save port COM OPERATION program and equipment Before starting the program you need to enable USB interface to the computer because otherwise the program will not recognize the COM port Then you can connect the interface to the
2. is normal but when the signal disappears completely ie when failure of the interface cable USB driver installation error or other factors then the string will be displayed continuously While errors in transmission or improperly selected COM port will be in August inscription appeared PROBLEM with received data from COM PORT reading will be stopped When the program is behaving inappropriately you must restart the program If during the measurement in the upper left corner does not display STATUS OK That is a problem with the interface such as damaged cable the wrong port etc The software is designed exclusively for 32 bit computers ie Windows Vista 64 bit will not be supported but Vista 32 bit and XP are supported Interface has a built in dongle without the original interface software will not work Follow the terms of the license the text is contained in the INFO tab
3. User manual of the analyzer high pressure common rail DT1000PC The tester is used to analyze high pressure common rail To measure the pressure uses a high pressure sensor for which you connect interface Before starting the program you must install the USB driver for the interface Drivers are supplied on CD INSTALLING USB DRIVER 1 plug USB cable to your PC 2 wait until the computer detects the interface 3 identify the drivers of the specific location ie the folder CD 4 two drivers are installed USB device and a virtual COM port if one is not already installed So we will repeat these steps two times 5 computer indicates that the driver is not digitally signed and asks if continue to confirm the installation continue anyway 6 after installing the computer will confirm the correct installation Now you need to check which COM port interface installed as virtual COM port To see which port is connected to the interface l press start 2 the right mouse button click on My Computer 3 click on properties 4 select the Hardware 5 click device manager 6 find on the list Ports COM and LPT 7 click on the cross in order expand 8 Now we see the USB Serial Port COM number INSTALLATION the high pressure analyzer 1 From the CD run the setup exe file 2 The first step is to install net Framework if it is not installed on your computer the program installs itself automatically During installation
4. car To do this connect GND black alligator clip to any GND point closest to the sensor GND because the car may not have proper conductivity and can falsify the measurement result Using the supplied needle pierce the signal cable The sensor has three wires 5 V the mass and tone if is connected wrong nothing will be damaged but the pressure signal will not be properly read When you connect select the COM port ports available are highlighted in green Next you must choose the type of sensor In older cars are used 1600bar sensors in the new 1800bar type of sensor need to check the documentation for the car The next step is to choose a scoop of interval measurement Generally the faster draws a graph it is more accurate ie at 10 ms data are most accurate then the measurement is taken 100 times per second Last step is to start the measurement by pressing START or STOP All settings can be changed during the measurement without the COM port Manipulating the COM port during the measurement will stop the measurement Next to the pressure gauge you can see the maximum minimum and average pressure during the entire measurement After stopping the measurement you are at the disposal of the cursor on the graph cursor is a blue horizontal line that you can move the mouse up or down studying the pressure levels on the chart moving the cursor around on the chart in the blue box is indicated pressure stopped at the po
5. int where the cursor Viewing range of the chart can be changed that is we can see chart the history between samples that interest us to change the range click on the start or end range ie 0 or 600 when you click the number will go into edit mode and enter the value from the keyboard what we need his can stretch the graph by setting a small difference between the start and end or see more samples enter wider range Storage of samples is set to 5000 so above this numbers will not be visible chart If during the measurement chart to fit on the graph then the graph will be move to the left Printing You can print a recorded chart the chart is printed only visible on the screen before printing you can see the print preview then click printer image to print or close to cancel Color pressure gauge can be changed by clicking on a shield You may remember the COM port number by clicking on the tab Save port COM In the Workshop please write Name of the workshop Nazwa warsztatu Addres of the workshop Adres warsztatu Vehicle registration number 7 Numer rejestracyjny pojazdu Save zapisz 1 Name of the Workshop 2 Addres of then Workshop 3 Vehicle registration number 4 clisk save These data will be printed on the printout NOTES The axis of the pressure adjusts automatically to the signal that was the most expanded during the measurement time shows waiting for transmission this

Download Pdf Manuals

image

Related Search

Related Contents

HDX 107018 Installation Guide  Conditions générales de ventes et de location  Instruction Manual FCX-AIII SERIES TRANSMITTERS  Deutsche Bedienungsanleitung Albrecht AE 7500  LW2310 Series Wireless Home Monitor  アンリツ株式会社 MT1810A 4 スロットシャーシ インストレーションガイド  HP Photosmart 6520 e-All-in-One Printer Reference Guide  