Home
user manual - Veilux.net
Contents
1. 18 7 1 Wash Brush Set 19 7 2 Heating Set 19 7 3Auxiliary Switch 1 Set 19 7 AAuxiliary Switch 2 Set 20 7 5 Proportion Joystick 21 IX Exception Handles 22 X The keyboard Key press Function 23 Keyboard Overview The keyboard is used for controlling the intelligent dome The keyboard is the main device between operator and device in the monitoring system It can be regarded as the main control keyboard and as the vice control keyboard 1 Liquid Crystal Display The LCD display board is regarded as interface between operator and device It is direct convenient easy to follow and conveys large amounts of information 2 Proportion Joystick Options PTZ control joystick and PT control joystick Use this joystick to operate high speed dome It is easy to use with good handling and flexible maneuvering 3 The lock function of th
2. Shift Call Set Dome Camera preset position function MPX Clear Dome Camera preset position function select menu items up MENU Enter keyboard menu Other key such as GRP SEQ NEXT AREA DVR is designed for other terminal device Camera Lens control Zoom in Press lt ZOOM in gt key joystick make a veer rotation Zoom out Press lt ZOOM out gt key joystick make a restores rotation Focusing Far Press lt FOCUS far gt key Focusing near Press lt FOCUS near gt key IRIS open Press lt IRIS open gt key IRIS close press lt iris close gt key V Keyboard Parameters Setting 4 The keyboard intelligent keyboard baud rate and communication protocol should be consistent with that of the dome camera 5 1 Keyboard Parameters Set Press MENU key enter Keyboard main menu Then Press MPX or Auto key until LCD displays 2 Keyboard setup Press Enter key into keyboard set up menu Press MPX or Auto key to enter the submenu Press EXIT key to exit to the main menu 5 1 1 Keyboard ID No Set Press Enter key on keyboard screen Keyboard setup until LCD displays Current keyboard ID No 1 Cur Keyboard ID XX Input New ID No Input the number 0 16 press Enter key for confirmation New ID will be in effect immediately ID 00 Main Control Keyboard ID 1 16 Vice Control Keyboard 1 The default keyboard ID number is
3. 3 Add pre position Number 1 8 4 Input a Group number using the number keys press Enter key the keyboard displays Add 5 Input desired Pattern Tour for the Group You can set up to 16 Preset Positions in one Group Example Desired pattern tour of 6 Preset Positions The sequence is Preset Position No 1 2 3 4 5 6 The keyboard displays Add 1 gt 2 gt 3 4 5 gt 2 gt 6 Press Enter key to confirm Pattern Tour Note When completed Press F1 ON to close and exit To Start the Scan In the Main Menu enter the Group Number and Press SCAN gt This dome can set 8 cruise groups with a Max of 16 cruise points Each group 1 128 points at any preset position gt Set the preset position at each of the cruise groups gt Dwell time at each preset position can be customized at a different time 1 60 seconds gt The speed to each preset position can be different 1 64 grades gt Default cruise group will auto scan by starting at present position point No 1 to preset position point No 16 16 Pattern tours Layout different preset position for Dome Camera as one group make the camera scan as set route in advance The running speed and dwell time of each preset position can be programmed Two pattern tours styles can be used A To and from Scanning 1 2 0 216 1 2 ee 16 1 v Make an auto circle scanning by points Press EXIT key and exit to default status of the key
4. Key to Confirm Press F1 ON key to move the cursor to Speed 00 lt Input 64 press Enter key Press F1 ON key to move the cursor to Time 00 lt Input 05 press Enter key Press F1 ON to move the cursor back to 1 Position 001 lt Press Clear to delete 0006 Input 02 press Enter key Press F1 ON key to move the cursor to Speed 64 lt Press Clear to delete 64 Input 10 press Enter key Press t F1 ON key to move the cursor to Time 05 Press Clear to delete 05 16 Input 10 press Enter key Do not forget to press ENTER to confirm each Preset Position Not doing so will result in lost information and the setting will not be effective 6 6 2 Pattern Tours Set 16 The keyboard can set pattern tour groups for the speed dome camera Before setting the Pattern Tours please set all preset positions in advance If the preset positions are not set the pattern tour will default to the pattern tour parameter Note can set 8 cruise groups 1 Press MENU key the keyboard displays Displays the Speed Dome Address 1 1024 1 speed dome Setup 2 Enter the correct Speed Dome Unit and Press Enter key Example Set Pattern Tour for Speed Dome Unit 02 The Keyboard displays Displays the Speed Dome Address 1 1024 1 speed dome Setup 3 Press MPX or Auto key until the keyboard displays Displays the Group
5. 7 5 1 7 Max Vice Control Number Set 7 5 1 8 Max Alarm Set 8 VI The Intelligent Keyboard Operation Way 8 6 1 Keyboard Communication Address Set 9 6 2 The Keyboard Control for Dome Camera 9 6 3 Auto Scanning 9 6 4 Set Preset Position 10 6 5 View Preset Position 11 6 6 Preset Position Parameter Set for the Dome Camera 11 6 6 1 Preset Position Speed and Dwell Time Set 12 6 6 2 Pattern Tours Set 6 7 Guard Location Set 6 8 Guard Location Parameter Set 17 6 9 Dome Camera Menu Set 18 VII Auxiliary Function Set
6. INDEX I Keyboard Overview 1 II Technical Parameters 1 Il Keyboard Drawing 1 3 1 The Keyboard Connection 2 3 2 The Keyboard Connection with the Dome Camera 2 IV Function Key V Keyboard Parameters Setting 4 5 1 Keyboard Parameters Setting 4 5 1 1 Keyboard ID No Set 5 5 1 2 Keyboard Baud Rate Set 5 5 1 3 key press Sound Set 6 5 1 4 Matching Resistance Set 6 5 1 5 Keyboard Communication Protocol set 6 5 1 6 Keyboard Test
7. Note can rotate at low speeds and at fast speeds Its speed can be divided into 64 grades 1 is the lowest speed and 64 is the fastest speed Press Exit key until the screen displays MON CAM 1 Inthe Current state Press MENU key The Keyboard displays 1 speed dome Setup 2 Enter the correct Speed Dome Unit and Press Enter key Example Preset Position for Speed Dome 3 The Keyboard displays Displays the Speed Dome 1 speed dome Setup Address 1 1024 3 Now the Keyboard displays Preset position 1 128 Running speed reset position 1 64 1 Position 000 Bi er Dwell time 1 60 lt _ Press F1 ON the keyboard to move the cursor up and down 4 Press Clear key to delete previous data before programming to a new preset position 5 Enter desired Preset Position and Press Enter key 6 Press F1 ON key to get to Speed Using the number keys enter the desired running speed 7 Press F1 ON key to get to Time Using the number keys enter the desired dwell time For example Set the running speed of preset position No 6 as Grade 64 fastest speed dwelling time is 5 seconds Set the running speed of preset position No 2 as Grade 10 dwelling time is 10 seconds 10 11 12 13 14 15 Press MPX or Auto key Press Clear key to clear the data Input 06 Note Setting the Preset Position No 6 press Enter
8. 4 alarm input i e 59 alarm dome camera can be connected with the keyboard at most VI Intelligent Keyboard Operation The startup interface is general operation menu after the keyboard is connected to the power supply LCD displays as follows Input any number within 1 1024 Dome Camera address in DATA area Press lt CAM gt key The relative number will display on CAM area 6 2 Keyboard Control for Dome Camera When Operating keyboard joystick in different directions Dome Camera will do relative movement The joystick excursion scope from center is direct ratio to running speed of Dome Camera 0 4 S 280 S 1 When the DATA column does not show 0 the DATA column displays the Address of the dome camera When the DATA column shows 0 the CAM column displays the address Of the dome camera Take Pelco P protocol for example to operate Dome Camera 6 3 Auto Scanning 2 Points Scanning 360 Scanning A 2 Points Scanning 12 The operator can also run a simple point to point scan also called back and forth scanning To do this set Preset Point A first at the same time set the dwell time at Point A and then set Present Point B at the same time set the dwell time at Point B Finally execute an outer command to scan between points A and B 12 2 points scanning It means scanning between two points The speed is Grade1 Grade 2 Grade64 from slow to fast Pr
9. MPX or Auto key three times until LCD displays 4 Match resister ON Displays the current set Press lt F1 ON gt key showing ON this will place suited resistance between RS485 D and D Press lt F2 OFF gt key showing OFF this will separate suited resistance from RS485 D and D Press Enter key for confirmation The normal status is open 5 1 5 Keyboard Protocol Set Press MPX or Auto key four times until LCD displays 5 Protocol MatPD Displays the current set Press 1 key showing protocol press Enter key for confirmation Press 2 key showing PEL D PELCO D protocol press ENTER for confirmation 6 Press 3 key showing PEL P PELCO P protocol press Enter key for confirmation default protocol is the our PELCO P Protocol 8 Sometimes matching resistance should be set at the control center in order to avoid reflection and disturbance from RS 485 communication signal and other signals 9 PELCO P PELCO D protocol The keyboard can be used together with other high speed domes When using a Camera please adopt the Vinte protocol 5 1 6 Keyboard Test Press MPX or Auto key until LCD displays 6 Keyboard test Press Enter key for confirmation a blank screen will appear Press any key except the lt EXIT gt key the relative name will display on the screen Press lt EXIT gt to leave
10. No 00 This is also the ID number for the Dome camera Verify the keyboard ID if the ID No is not set correctly you will not be able to control the dome camera 5 Keyboard ID is used to set multi controlling keyboards when a series of Cameras are required to be controlled A group of speed domes can be supported by one main control keyboard and 16 vice control keyboards 6 Main control keyboard Its ID is 00 It enjoys priority wnen several keyboards are in control Only one of several keyboards can be set as main control keyboard ID must be sole not repeated 7 Vice control keyboard ID is to be 01 16 keyboards 5 1 2 Keyboard Baud Rate Set Press MPX or Auto key until LCD displays Current baud rate 2 Cur Baud Rate XXXX Input new baud rate Optional baud rate 9600 4800 2400 and 1200 Default baud rate 9600bps Input your required baud rate in DATA area and press Enter key for confirmation New baud rate is in effect immediately 5 1 3 Key press Sound Set Press MPX or Auto key until LCD displays Displays current set 3 Current sound ON Select Sound preference Press lt F1 ON gt key showing ON turns on the sound function Press Enter key for confirmation Press lt F2 OFF gt key showing OFF turns off the sound function Press Enter key for confirmation The normal sound status is open 5 1 4 Matching Resistance 150Q Set Press
11. ON key ON Startup the guard location Press F2 OFF key OFF Stop guard location Example Press F1 ON key ON to start up guard location Dome will rotate to set position within XX seconds 2 In the Main Menu screen press MPX or Auto key until key once LCD displays Displays Current Speed 1 speed dome Setup dome address 3 Press Enter key to Confirm 4 Press MPX or Auto key until LCD displays 4 Watch Position 5 Input the desired waiting time using the number keys Example After inputting time 05 press Enter key 4 Watch Position 6 8 Guard Location Parameter Set 1 When the keyboard is under default Main Menu status press MPX or Auto key until the keyboard displays 1 speed dome Setup 2 Press Enter key to confirm 3 Press MPX or Auto key until the keyboard displays 3 Press Enter Key To 4 Move the joystick rocker to the target position you would like to set as the Guard Location 5 Press Enter key to set the Guard Location The position is set as the guard location 6 9 Intelligent Keyboard Menu Set for Press MPX or Auto key until keyboard will display Press MPX or Auto key 5 dome menu Press enter to menu 5 Dome menu Data 0000 Data 0000 gt Press Clear key to delete previous data input required address of 1 1024 press Enter key Operatin
12. Set joystick veering limit value limited for PTZ keyboard only Move the middle pillar of joystick to the bottom veer set its veering limit value by pressing Pan_B key See below chart for setting reference Operating Key Function Set joystick restores limit value Set joystick veer limit value Set joystick left limit value Set joystick right limit value Set joystick up limit value MON Set joystick down limit value AREA Set Joystick middle value IX Exception Handles Exception phenomena No display on the screen when the power on No way to control designated dome or high speed dome Possible reason 1 Power supply is not connected properly 2 Watt is not enough 1 Protocol is not correct 2 Baud rate is not correct 3 Controlled address is not correct 4 the polarity of control line is not correct Relative solution 1 Check connection of power line 2 See if power supply is AC DC 9V 12V 1 Check if the keyboard protocol accords with that of dome or high speed ball or not 2 Check if the baud rate of the keyboard accord with that of dome or high speed ball or not 3 The number in CAM or DATA area can t accord No Bi sound when Key press sound is Start up key press sound in pressing key closed the keyboard set Other phenomena Back to manufacturer for maintenance 4 When using the keyboard to control other dome ca
13. board Input cruise Number adjust key SCAN into to and from scanning as the above route B Cruise Scanning Anni 45 1 6 1 Bere eeeeee Faq Es dese 15 16 15 Make an auto cruise scanning Press EXIT key and exit to default status of the keyboard Then input cruise group No and then input Shift Scan Into cruise scanning as the above route N If a point is not set or is deleted after being set there will not be any scanning to these points i Select Add the preset position to cruise Press Enter key for confirmation after adding a preset position Press F2 OFF key exit when setting is finished Please set the preset position parameter before setting its pattern tours If not setting dome preset position Dome Camera will operate default preset position parameter when it runs its pattern tours 6 7 Guard Location Set The guard location is an important position that the camera will come back to automatically when there is no operation for a defined period The user can set a guard location and control the waiting time to the guard location starting and stopping 1 255S before allowing the camera to return to the guard location Use the keyboard to set the guard location and its waiting time Turning the Guard Location On Off and Setting delay time to Guard Location 1 To set the guard location to start or stop The keyboard recognizes this action as a Switch ON Start OFF Stop Press F1
14. e keyboard can prevent unauthorized users to operate the keyboard 4 Provide RS485 control output signal and also offer the standard RS232 control signal II Intelligent Keyboard Technical Parameters 1 Communication baud rate 1200bps 2400bps 4800bps 9600bps 2 Protocol PELCO_D PELCO_P 3 Data Format N 8 1 4 Power input AC DC 9V 12V 5 Max controlled dome camera 1024 2 6 Power 5W lll Intelligent Keyboard Drawing 3 1 Intelligent Keyboard Connection Insert one end of keyboard data line into keyboard A2 B2 on the right of its back panel Proportion Joystick The speed of the joystick is a direct ratio to the running speed of the dome camera 2 The keyboard can set up to 1024 sole addresses However it does not control 1024 dome cameras directly The strength and weakness of the RS485 control signal determines the speed dome quantity It can control up to 1024 VPTZ dome cameras through signal compensation devices The RS485 can control 32 dome cameras at most if it has no signal compensation Wire Box Inner Function Picture Qonvert Box PIN Define 1 rey 2 D R232 RXD R232 TXD D RS485 B RS485 A wIANVAYW mm 12345678 3 2 Keyboard Connection with Dome Camera RS485 psag5 RS485 dome camera dome camera dome camera 4 When dome camera is furthest away from the control keyboard Please set switch of matching resi
15. ess Clear key on the keyboard DATA area to delete value on DATA column 1 To set Point A Move the joystick to the desired position 2 In the Main Menu enter a dwell time for Point A Example If Dwell time is 2 seconds the keyboard displays 3 Press PAN A key 4 To set Point B move the joystick to the desired position 5 In the Main Menu enter a Dwell time for Point B 6 Input the grade Speed 1 64 and Press AUTO key This will start up 2 points Scan B 360 Scanning 14 The Operator can also start an auto cruise scan This scan will rotate 360 from the desired position Press Clear key on the keyboard DATA area to delete value on DATA column 1 In the Main Menu input desired cruise group No Example Desired Group No is 4 the keyboard displays MON CAM 2 Press Shift Scan key to place PTZ into cruise scanning OR 1 Move the joystick to desired position 2 Input the running speed 1 64 and then input Shift AUTO key 1 Shake the keyboard joystick to stop auto scanning 6 4 Set Preset Position 1 Press Clear key to clear the number in the data area 2 Enter the Preset Position Number you wish to set You can set up to 128 Preset Positions Ex Set Preset Position No 1 the keyboard displays Displays the Preset Position Number MON CAM ne 3 Adjust the camera to the desired position including location camera zoom focus and iris 4 Press Shift Call ke
16. g menu see below for reference Operating Key Function Enter Enter Login Exit function MPX Dome menu cursor up Auto Dome menu cursor down Call Dome menu cursor right Scan Dome menu cursor left Pan_A Select DVR Keyboard function menu exit to upper menu Dome camera menu set should consult Dome Camera manual VII Auxiliary Function Set 4 The auxiliary function is used with other Pelco P products It is not used with the Dome camera 7 1 Wash Brush Set 1 Press MPX or Auto key until LCD display as below 3 Wash Number 0001 OFF Set Wash Brush open by pressing down F1 ON key Set Wash Brush close by pressing down F2 OFF key 7 2 Heating Set 18 Press MPX or Auto key until LCD display as below 4 Warm Number 0001 OFF Set Heating open by pressing down F1 ON key Set Heating close by pressing down F2 OFF key 7 3 Auxiliary Switch 1 Set Press MPX or Auto key until LCD display as below 5 Auxiliary 1 Number 0001 OFF Set Auxiliary Switch 1 open by pressing down F1 ON key Set Auxiliary Switch 1 close by pressing down F2 OFF key 17 This function is used for the frontal terminal device with the wash brush function only 18 The fan and heater in the speed dome camera is always under auto temperature control status This function will auto start when the temperature reaches hi
17. gher point or lower point 7 4 Auxiliary Switch 2 Set Press MPX or Auto key until LCD display as below 6 Auxiliary 2 Number 0001 OFF Set Auxiliary Switch 2 open by pressing down F1 ON key Set Auxiliary Switch 2 close by pressing down F2 OFF key 7 5 Proportion Joystick 4 This function has been set well before the keyboard leaves the factory The speed of the Joystick is a direct ratio the running speed of the dome If it is not a direct ratio reset the keyboard joystick parameter Press MPX or Auto key until LCD displays 8 Joy Stick Set Tilt 000 Pan 000 Display Joystick value Up Down Left Right 8 1 Set Joystick middle value dwelling time When stop on the middle part set joystick middle status by pressing AREA key 8 2 Set joystick up limit value Move the joystick to top up set its upper limit value by pressing SEQ key 8 3 Set joystick down limit value Move the joystick to bottom set its lower limit value by pressing MON key 8 4 Set joystick left limit value Move the joystick to left side set its left limit value by pressing GRP key 8 5 Set joystick right limit value Move the joystick to right side set its right limit value by pressing Next key 8 6 Set joystick restores limit value limited for PTZ keyboard only Move the middle pillar of joystick to the bottom extrorsely set its restores limit value by pressing Pan_A key 8 7
18. meras keep the keyboard setting Baud rate protocol address consistent with the dome camera Some dome camera addresses have a 1 difference the keyboard does not X Key press Function Protocol Operating Adjust preset position Shift Call Set preset position Shift_ Pan A Limited B Line Scan scanning between two points Shift _Auto Panel Scanning Mode Scanning Scan Start up the perambulate group Shift Scan Start up intercourse perambulate group LCD show CAM area address PELCO_D Protocol Operating Call Adjust preset position Shift Call Set preset position MPX Clear preset position
19. stance as ON status 3 R is on behalf of matching resistance The farthest dome from the control center should be set as its matching resistance in order to minimize RS485 bus reflection and disturbance The 8tbit of SW3 shows ON status which means the BUS matching resistance has been connected IV Function Key gt Joystick Control Dome Camera running Up down Left Right Left up Left down Right up right down camera lens zoom in and zoom out Keyboard joystick can t control Dome Camera lens zoom in and zoom out gt Dome Camera Selection and Auto scanning Control gt Data Input Clear and Confirmation gt Menu Turning Exit and Preset Position Set gt Dome Camera Lens Control and Keyboard Lock and Unlock gt LCD Data Display Function Key Explanation is As Below KEY Function 0 9 Data key Clear Clear the inputted number on the DATA display area MON matrix monitor selection CAM Dome Camera address selection Enable Alarm open set 4 Shift Enable Alarm close set 4 Shift Clear Clear Alarm Pan_A Set the start point of dome camera auto scanning Pan_B Set the end point of dome camera auto scanning Auto Finish Dome Camera auto action select menu items down Shift Auto Adjust Dome Camera pattern tour function Scan Startup scanning group model NO 1 Shift Scan Startup scanning group model NO 2 Call Call Dome Camera preset position function
20. the testing status and return to the main menu aN If the keyboard test does not display the correct Keyboard protocol the keyboard may be damaged 5 1 7 Max Vice Control Number Set 1 Press MPX or Auto key until LCD displays 7 MAX 16 SLAVE gt Default Setting Input number 00 16 Press Enter key for confirmation 4 If the keyboard is set as 01 02 16 it will be considered as the total Vice control keyboard quantity separately 5 1 8 Max Alarm Set 11 Press MPX or Auto key until LCD displays 8 MAX 239 ALARM Default setting Input number the biggest alarm input terminal number is 239 Press Enter key for confirmation 14 If the keyboard is set as 000 001 002 239 the total relative quantity for Alarm input terminal will be in operation 10 When there are two or more than two keyboards in one system please use the main control keyboard to set the total desired vice keyboard quantity should be set 16 vice control keyboard at most If the vice keyboard quantity are not set the vice keyboards will not control camera dome The number desired to input should be more than or equal to the total actual vice control keyboard quantity 11 You should set the total alarm input terminal quantity for alarm dome camera if such dome camera is adopted The number desired to input should be more than or equal to the total actual alarm input terminal quantity One dome camera has
21. y for final confirmation 13 Dwelling time Can set dwelling time at one preset position 1S 2S 14 360 scanning 360 scanning at one preset position Dome speed is Grade Grade 2 Grade 64 from slow to fast 6 5 View Preset Position 1 Press Clear key to clear the number in the data area 2 Input the address of the dome in the Data area press down lt CAM gt key and show it in DATA area 3 Input the preset position you would like to view Example View preset position No 5 Displays the Preset Position MON CAM Number 1 128 4 Press CALL key The dome will move to the Preset Position No 1 After pressing CALL key dome camera will nun to the present position you Would like to view at Grade 64 280 S speed 6 6 Preset Position Parameter Set for the Dome Pelco P protocol has this function 15 Press MPX or Auto key until LCD displays 1 speed dome Press Clear key to delete previous data Input required address code XXXX 1 1024 for control Press Enter key for confirmation Press Enter key into preset position set of dome camera A The below menu is submenu Press FUN into submenu after entering this main menu 6 6 1 Preset Position Speed and Dwell Time Set Dome Camera has the capacity to set up to 128 preset positions through the keyboard It can set a running speed at each preset position from 0 4 s to 280 s 1 64 grades and dwell time from 1 60 seconds
Download Pdf Manuals
Related Search
Related Contents
車種別適合表 Samsung CLP-600N Käyttöopas Apple G5 User's Manual Rugged Safe Datasheet Sony CDP-CA7ES Operating Instructions Copyright © All rights reserved.
Failed to retrieve file