USER`S MANUAL - MARUSON Technology

image

Contents

1. 3 beeps 5 seconds ON 0 25 seconds OFF 0 25 seconds 3 times 3 5 seconds OFF B5 3beeps 30seconds ON 0 25 seconds OFF 0 25 seconds 3 times 28 5seconds OFF Recycling Information Your UPS contains Non Spill Sealed Lead Batteries On the battery you will find the battery name Please reference the chart below for recycling information Other brand s of battery please contact Maruson Technology Corp If outside the USA or Canada please contact your local authorized distributor Battery Name Recycling inside the USA Vision Battery 1 877 730 2877 First Power Battery 1 877 730 2877 1 800 278 8599 BB Battery SPECIFICATIONS Model Numbers TOW 1500LCD Capacity 1500 VA 900W Nominal Input Voltage 120 Vac 120 Vac 108 130Vac 3 50 60 Hz auto sensing 8 Outlets 4 Battery Backup amp Surge Protection 4 Surge Protection only Lighting Surge Protection 320 Joules Transfer time to Battery AC 2 6ms typical Maintenance free lead acid battery 2 12V 9 Ah Typical Backup Time Up to 55 Minutes LAN Phone Fax Protection Short Circuit Protection Circuit Breaker 0 to 95 non condensing Storage Temperature 15 C 50 C Net Weight 29 3 Ib Dimensions HxWxD 10 8 x 3 4 x 16 1 IN Nominal Output Voltage Automatic Voltage Regulation AVR Frequency Outlets Battery Specification Specifications may change without prior notice All Trade Marks Belong To Their Respected Owners
2. 3 Always disconnect the input power cord from the wall outlet before replacing the battery 4 When replacing the battery use the same number and type of battery 5 Do NOT dispose of the battery in a fire the battery may explode 6 Do NOT open or mutilate the battery Batteries contain an electrolyte that is toxic and harmful to both the skin and eyes 7 Proper disposal of the battery is required Please refer to your local laws regulations regarding battery disposal 8 Use tools with insulated handles to replace the battery to avoid personal injury Due to energy hazards please remove wristwatches and jewelry such as rings when replacing battery BATTERY CONNECTION REQUIRED BEFORE USE Connecting the Battery How to hook up the battery before installing the UPS 1 Remove the screws from the bottom of the front panel 2 Grasp the panel cover downward off the UPS 3 Connect the battery positive wire red 4 Put the front panel cover upward 5 Bolt the screws USER S MANUAL INSTALLATION AND OPERATION The following steps explain how to connect and operate the UPS 1 Connect the UPS to a grounded power outlet NOTE It is recommended that the battery be charged for at least 8 hours to ensure full charge before placing the UPS in service 2 Plug your computer monitor or load to be protected into the Battery Backup amp Surge Protection outlets These outlets will provide emergency battery backup powe
3. TROUBLESHOOTING UPS will not turn The UPS is not Ensure the UPS is securely connected to the connected to an AC outlet power source Circuit Breaker has Reduce the amount of equipment tripped plugged into the Battery Backup amp Surge Protection outlets of the UPS Reset the circuit breaker by pushing it back in Switch the UPS back on UPS is making a The Battery Backup amp Turn off the UPS and reduce the continuous sound Surge Protection amount of equipment connected to and the outlets are overload __ these outlets Overload indicator is on UPS does not The UPS battery is Charge the battery for 8 hours The provide discharged due toa UPS runtime is reduced until the expected eid aie and has battery is fully charged runtime ge Back UPS is heavily Unplug non essential equipment loaded printers scanners etc from the Battery Backup outlets and plug into Surge Only outlets Disconnect non essential equipment from the UPS Reset push in the circuit breaker and switch the UPS on UPS does not The UPS circuit power essential breaker tripped equipment during an outage Plug equipment in one at a time If the circuit breaker trips again disconnect the device that caused the breaker to trip The battery has Replace the battery or the battery reached the end of its module life Equipment plugged Unplug device from Surge Only outlet into a Surge Only and move to a Battery Backu
4. UPS SYSTEMS Power Solutions for All Your Needs TOW 1500LCD The uninterruptible power system UPS protects your sensitive electronic equipment from power problems such as power failures power sags power surges brownouts and line noise Features e Processor controlled voltage regulation e Eight outlets Four with surge and backup protection Four with surge protection only e Telephone line surge protection jacks e Cold start capability e USB communication port SAFETY INSTRUCTIONS Once you have received the UPS product you should remove and inspect the product for shipping damage If any damage is found please notify the carrier and your dealer Please keep the shipping carton and the packing foam in the event the product must be returned to the factory for service A qualified technician must perform maintenance other than battery replacement Failure to do so could result in an electrical shock Although the unit may be unplugged from utility power hazardous voltage still may be present through the battery 1 Place the UPS indoors in an area that has adequate airflow and is free from excessive dust Do NOT allow the UPS to be exposed to moisture rain excessive heat or direct sunlight 2 Use of the UPS product in life support applications where failure of this equipment can reasonably be expected to cause failure of life support equipment or to significantly affect its safety or effectiveness is NOT recommended
5. hat a fault condition has occurred Flashing Red LED indicates an overload condition or that the battery should be replaced Solid On LED indicates that the output is shorted or an internal UPS fault exits See the Indicator Table below for further detail 4 Backup mode Yellow LED Indicates that the UPS is operating on battery and providing regulated AC power to the backup only outlets and the connected equipment 5 AC mode Green LED Indicates that AC utility power is present and regulated power AVR is applied to the connected equipment 6 LCD Display State 1 UPS load capacity display Load pixel is 20 40 60 80 100 State 2 UPS battery capacity display Battery pixel is 20 40 60 80 100 State 3 UPS input output voltage amp frequency display Click the LCD choose switch it will cycle display input voltage input frequency output voltage and output frequency on the screen 7 USB Communication Port The built in USB port connects to your computer The PowerGuard Smart monitoring and shutdown software provided can automatically save your files and shut down your computer in the event of a prolonged power outage The software also provides information regarding the status of your utility power line Installing software lt X Follow the on screen instructions a gt al If autoplay Is not enabled on the computer please follow instructions below Double click on My Computer on the desktop Doub
6. le click on the CD ROM drive icon and follow the on screen instructions 8 Data Phone Fax Protection Connectors 9 Surge Only Outlets Four Nema 5 15R output receptacles that will provide surge and spike protection only 10 Battery amp Surge Outlets Four Nema 5 15R output receptacles that will provide both battery backup and surge protection 11 AC Input Power Cord Plug the AC power cord into your power source 12 Coax in TV TNT Satellite reception protection 13 Circuit Breaker re settable The button will protrude when the overload condition occurs If the button protrudes disconnect some non essential equipment and reset the circuit breaker by pushing the button inward 14 Coax out TV TNT Satellite reception protection INDICATOR TABLE Status Indicators The UPS provides both visual and audible status indicators Visual indicators consist of three LEDs to represent the following conditions e On utility power operation e On battery power operation e UPS fault alarm LED and Alarm Indicator Table LED LED On Blink2 battery DC mode battery Short Fault mode Over Bat Bat Fault Blink 1 ON 0 5 seconds OFF 1 seconds Blink 2 ON 0 25 seconds OFF 0 25 seconds B1 1 beep 5 seconds ON 0 25 seconds OFF 4 75 seconds B2 1 beep 0 5 seconds ON 0 25 seconds OFF 0 25 seconds B3 2 beeps 5 seconds ON 0 25 seconds OFF 0 25 seconds 2 times 4 seconds OFF B4
7. p outlet outlet Flashing Internal UPS fault Indicators Maruson Technology Corp Tel 626 912 8388 Fax 626 912 8680 18557 East Gale Ave E mail Custsrv MarusonUSA com City of Industry CA 91748 Web www MarusonUSA com Contact Technical Support see Service and Support below
8. r during power problems as well as protection from surges and spikes CAUTION Do NOT plug LASER PRINTERS into the Battery Backup outlets CAUTION Do NOT plug ACCESSORY SURGE strips into the Battery Backup outlets Plug your peripheral equipment or non critical loads printer scanner fax speaker etc into the Surge Protection outlets These outlets provide Surge and spike protection only they will NOT provide battery backup power during a utility power failure 4 Switch on the UPS while the connected equipment is off 5 Turn on your connected equipment when the AC mode LED light is illuminated INDICATORS O 0 O Et ch LL State 1 aa State 2 State 3 lt 77 _ 116 E 1 On Off Push Button This On Off switch controls power to your equipment and performs a self test to detect inverter line battery status amp LEDs NOTE Turn on the UPS Press and hold the switch for more than one second and release the switch after the beep The UPS will start and provide the stable power to your equipments NOTE Turn off the UPS Press and hold the switch for more than one second and release the switch The UPS will shut down completely NOTE Perform Self test The UPS will perform self test for about 5 seconds when the UPS is turned on 2 LCD Choose Button Click the switch each time it will display the UPS s special status and data s on the screen 3 Fault Warning Red LED Indicates t