1. this port is for voice output it can be connected to the speaker the other port of the speaker connect to ground you can control it by call in or send the SMS If this function avails the light of OUT 3 will light on the panel RELAY1 RELAY2 these two ports will close 3 minutes when alarm happens you can use these two ports to start the power supply of the camera when alarm happens also you can disable this function by set command 16 1 you can also make this relay close or open anytime by sending SMS or dial in 94 1 or 94 0 SIREN this port can output siren tone alarm it s to be connected with the siren the other port of siren connect to ground GND power ground lll How to setup the alarm phone numbers and SMS PDF 3ceE ERY pdfFactory Pro iwWHIWeA Gt www fineprint cn 1 you can send the message to the unit to setup the 5 groups of alarm phone numbers and 7 kinds of SMS The command format password operation code content For example 123456 51 13905950001 save first group alarm phone number into the base 123456 52 13905950002 save second group alarm phone number into the base 123456 53 13905950003 save third group alarm phone number into the base 123456 54 13905950004 save fourth group alarm phone number into the base 123456 55 13905950005 save fifth group alarm phone number into the base 2 We have fixed 7 kinds of SMS in the base but you can change it The first five messages are for 1 5 zone
2. the phone not need input password if you do not want the unit to dial next phone numbers just press 1 1 or 1 2 to re turn the unit into Arm status 5 When there is alarm you can use the controller to change the base into disarm status when you are in nearby can control the situation 6 Normally the unit has inner battery it will send out SMS message external power failure or external power recovery when external power supply lost or recovery V How to control the base 1 Send message to the host phone number SIM Card number Send message to the unit password 123456 add the following commands to control the unit 2 Call the host phone number SIM Card number Call in the unit and enter password 123456 then input the following command to set the base Commands table com Function com Function 16 1 Disable Relay close 3 Min when 16 0 Set Relay close 3 Min when alarm alarming 30 show the arm and disarm status of every zone SMS command applicable only 31 Change password Enter a new password 1 6 bit 38 Set arm of zone wireless zone 1 16 wire zone 21 23 NOTE to arm each zone 39 Set disarm of zone wireless zone 1 16 wire zone 21 23 NOTE to disarm each zone DO show preset phone numbers in the base SMS command applicable only 51 First group phone number 0 15bit 52 Second group phone number 0 15bit 5D3 Third group phone number 0 15bit 54 fourt
3. the unit is powered on wireless detectors can be coded into the unit the light flash in red if the coding process successful After 20 seconds SIGNAL light flash orange to show it start to search for GSM network if still flashes in orange shows SIM card is fixed incorrectly or GSM network is not good If SIGNAL light keep still in green shows no phone number stored in SIM card if every thing is ok SIGNAL light will flash slowly in green Out arm mode or flash quickly in green Home arm mode or keeps still on green Disarm mode alarm happens the SIGNAL light will flash in red and start to dial out and sent SMS 2 About OUTPUT light If unit O1 output high 5V the OUT 1 light will be on If unit O2 output high 5V the OUT 2 light will be on 3 About TALK light OUTPUT 3 If the unit speaker is in working status the Output3 will be on shows you can talk to the spot 4 About RELAY light If 2 outputs of the relay on the unit are connected the relay light will be on 5 About SIREN light if the siren is sounding the siren light will be on 6 About MONITOR light If the monitor function is opened the monitor light will be on Basic Kit contains Alarm system control unit 1 pc Wireless PIR detector 1 pc Wireless door gap sensor 1 pc Remote controller 2 pcs Antenna 1pc Mini wired siren 110dB 0 3m 1 pc Power supply with back up 1pc Installation user m
4. 2 Add sensors into inner defense zone Detectors in this zone are ready to work when you set Out Arm and will not work when you set Home Arm When the GSM host begins to be powered on the status LED light on panel will be red Push the reset PDF sce ERY pdfFactory Pro iWHIWeA Get www fineprint cn button for one second the status LED light will light up in orange for 20 seconds This is code learning mode of inner defense zone You can trigger the sensors or detectors the LED will flash in red to show it is coded successfully into inner defense zone For above operation the host will exit code learning mode 20 seconds later automatically and enters into working mode the light on panel changes to orange to search for GSM network then to green Note If there were 4 wireless sensors in the host stand for zone 1 to zone 4 then the new added sensor will be 5th zone in the host VIII How to cancel the lost detectors In case of the coded sensors or detectors are lost you can cancel the coded information of these detectors so that they can not control your alarm system Keep pressing the reset button then power on the system one beep sound or LED flashes shows reset is successful All registered detectors have been deleted from the unit You can register them again with the above mentioned procedures System reset will not change the SMS message SOME NOTES 1 About SIGNAL LED light SIGNAL light keep in red for 20 second after
5. Business Home GSM Alarm System CIID Installation and Users guide PDF SEH pdfFactory Pro whHheAS Get www fineprint cn I General information GSM 900 1800 1900 bands can be used all over the world Full duplex communication with the base Monitor environment on the spot Voice and message alert Set alarm ON or OFF by remote controller Call in to set alarm ON OFF Monitor Output Send SMS to set alarm ON OFF Monitor Output 5 group phone room number 1 group alarm monitor center phone 2 group phone to report alarm and non alarm status Can program 7 group alarm messages 3 zones for wired detector 16 zones for wireless detector Easily set ON or OFF for every wire or wireless detector 1 relay output to power on camera when alarm 2 output for home appliances connection lamp cooker air condition SMS inform for external power failure or recovery Indoor and outdoor alarm controller 9H HH HH HHHHHHHHOHOY ll Installation guide 1 Insert SIM in alarm unit Press the yellow point on the unit with a pencil tip or other tools SIM tray will come out put the SIM into the tray and make sure the Metal contacts of the SIM to be downwards then push the tray back Before insert SIM in alarm unit using a regular mobile phone do the following steps Set PIN code request to off Delete all stored numbers 2 Connect the antenna Screw the antenna to the unit carefully do not over tighten the nut or leave
6. ansmission Current lt 20mA Transmission Frequency 315 433 40 5 MHz Transmission Distance No obstacle 80m Detective Speed 0 3 3m s Detective Distance 5 12m Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 10 C 40 C Humidity lt 90 rh Remote Control Power Supply DC12V inner DC12V battery Transmission Current lt 15mA Transmission Frequency 315 433 40 5 MHz Transmission Distance No obstacle 80m PDF 3c EAI pdfFactory Pro WAIRERE www fineprint cn
7. anual 1pc Standard components and optional available components The following sensors can be optional Additional wireless products PDF sce EAI pdfFactory Pro iwHIWRA Gt www fineprint cn PIR Detectors Smoke Detectors Panic Buttons Door Window Remote Controls LPG Gas Detectors jap sensors Optional sensors detectors are packed separately It includes remote controllers wireless PIR wireless gap sensor wireless gas detector wireless smoke detector panic button baluster etc you may buy according your specific requirements Typical house configuration m 4 External Sirens Dooriwindow Garage pao g F a a Ar inal PS E ee ee fi Fi Fi F z po ra SS Moke D FIR Movement Detector Detectors i al SOME TECHNIQUE PARAMETER Static current 50mA Power 9V 12V DC Working temperature 20 C 85 C GSM850 900 1800 1900MHz PDF SEH pdfFactory Pro whHheAS Get www fineprint cn Receiving code ASK Frequency 315 433 MHz wireless distance 100 m wireless detectors 16 wire detectors 3 Wireless Gap Detector Door Window Contact Power Supply DC12V inner 12V battery Static Current lt 20 mA Transmission Current lt 15mA Transmission Frequency 315 433 40 5 MHz Transmission Distance No obstacle 80m Internal Distance 15mm Working Condition Temperature 10 C 40 C Humidity lt 90 rh Wireless P IR Detector Power Supply DC9V inner 9V battery Static Current lt 100 mA Tr
8. ce is under 220 ohms Wired sensors 3 COO 0 CIAN 33 0201 Tf SIM RESET OFF ON ANT 6 Connecting switched output devices Home appliance Control Three open collector outputs 01 02 and O3 and one internal relay controlled by telephone are available Internal onboard relay is activated when an alarm occurs and can be deactivated reactivated through telephone commands or SMS text message It can be used as example to command an external lamp LAMP AC 220V MAX TOW DEII Mi 0 03 0201 1 2 I SIM MESET OFF OH ANT Open collector outputs can be used directly if your equipment can operate a relay Do connect an antiparallel diode with relay coil These outputs can be operated only by telephone or SMS text message commands Wiring Explanation For home appliance control for special order The controller box has four wires a Two yellow AC 220 wires to be connected with Home appliance b GND 12V DC wires to be connected with a 12V DC Power supply 7 Configuration of the alarm unit There are 10 connect ports at the top side of the unit GND SIREN RELAY1 RELAY2 SPEAKER 0O3 O02 O1 13 12 11 11 12 13 these 3 ports for line input every port can be connected with ground or open to make alarm out O1 O2 these 2 ports for output you can call in or send SMS to set it If output of these goes high the light of OUT 1 or OUT 2 will light on the panel unprofessionals should use it with caution SPEAKER OQO3
9. gered 123456 86 Middle window open save sixth to sixteen SMS message into the base as sixth wireless detectors triggered 123456 87 Up floot open save seventh group message into the base as port 1 to 3 wire detectors triggered IV How to test the base alarm When you start the base if the base is in Disarm status the signal LED keep still green you can use controller to change the base into Arm status or you can send SMS 123456 1 1 to the base to change the base into Arm status the signal LED will change to flashing green 1 Under the Arm status with green LED on any port of input 11 12 13 short circuit or disconnected or any wireless detectors has been activated or you press the emergency key on the controller the alarm system will send alarm information by SMS and dialing out stored telephone numbers 2 It will send SMS before dial alarm phone numbers If the SMS function has been closed or limited it will only dial out the preset telephone numbers You can make them disarm with remote controller PDF cee EAI pdfFactory Pro WAIRERE www fineprint cn 3 When there is alarm it will dial out phone numbers you can answer the phone not need input password to operate it press 3 1 to start the siren and press 3 O to stop it press 4 1 to listen in and press 4 O to stop it press 93 1 to talk with the spot and press 93 O to stop it 4 When there is alarm it will dial out phone numbers you can answer
10. h group phone number 0 15bit 85 86 Sixth group Message 0 24bit 93 1 Set talk to the host available Output 93 0 Set talk to the host unavailable Output 3 3 94 1 Set Relay to be connected 94 0 Set Relay to be disconnected PDF cee EAS pdfFactory Pro WHW GME www fineprint cn 95 1 Set alarm when line input 1 open 95 0 Set alarm when line input 1 connect to Gnd 96 1 Set alarm when line input 2 open 96 0 Set alarm when line input 2connect to Gnd 97 1 Set alarm when line input 3 open 97 0 Set alarm when line input 3connect to Gnd Note 1 above table stand for default setting 2 Inthe above phone operation one beep shows your input successful a long beep shows the sentence you input is successful two short beeps shows your input is failed you should try again 3 In the above SMS operation you will receive a reply message for confirmation after you send the message command to the base the replied message as follows DisArm Sms ON Phone ON Siren ON Center Tel OFF Arm Center Tel OFF DisArm Center Tel OFF you will Know the working state of the base then arm disarm or alarm if the replied message is the present state of the unit you may send wrong message 4 You also can send the command to check out the present state of the unit 5 When the external power is cut off the system will send SMS Power changer off to inform When the external power recovered the system wil
11. it too loose 3 Connect the power supply which must be 9V 12V DC and over 1000mA current The signal status LED on the unit will turn red and last for 20 seconds this shows it waiting for wireless detectors to be coded into the unit After 20 seconds the signal status LED will flash in orange this indicates the unit is checking the SIM card and searching for GSM network After it finish checking if the signal status LED changes to slowly flashing in green it shows phone numbers have been saved in the unit and the unit is now in Arm status If the signal status LED keeps still in green this shows phone numbers have not been saved in the unit and the unit is in Disarm status you can dial in or send SMS to program the phone numbers 4 Connect the siren to alarm system Connect the black wire to GND port and the red wire to siren port D Black Red E OOUOOOOOOT oO Dol f o o0 O30201 B Bl SIM RESET OFF ON ANT 5 Connecting wired sensors PDF cee EAS pdfFactory Pro iWHIWRA Gt www fineprint cn Three inputs are available to connect wired sensors Inputs are independent and not coded as different zones When these sensors are triggered the unit will sent SMS message Wired Activated 1 3 Sensors must be NO normally Open type More than 1 sensor can be applied at one input connecting their alarm contacts serial The inputs can be connected with any number of wired sensors as long as total resistan
12. l send SMS Power changer on to inform VI How to use controllers O The remote controller has four buttons Out Arm key set alarm works when no one is at home all the detectors will be in working status the light on panel will slowly flash green Home Arm key set alarm works when there is someone at home detectors which inside of the house in inner defense zone will not work only the detectors outside of the house in outside defense zone will work for the people inside can move conveniently but others who break in from outside will trigger the alarm Disarm key set alarm system disarm all the detectors are disarmed the light on panel will keep in still green Alarm key set emergency alarm the light on panel will flash red the system will make alarm and the unit will send the SMS and dial out phone numbers VII How to add more detectors You can add new sensors or detectors such as wireless door sensors PIR Sensors gas and smoke detectors into the unit 1 Add sensors ready to work when you set both Out Arm and Home Arm When the GSM host begins to be powered on the status LED light on panel will be red for 20 seconds this is code learning mode You can trigger the sensors or detectors and the red LED will flash to show it is coded successfully into the host The coding mode ends 20 seconds later automatically and system enters into working mode status LED light on panel will change to yellow then to green
13. wireless detectors The sixth messages are for 6 16 zone wireless detectors The seven message are for wired port I1 12 IS When the first wireless detectors triggered the SMS message will be Wireless Activated 01 When the second wireless detectors triggered the SMS message will be Wireless Activated 02 When the third wireless detectors triggered the SMS message will be Wireless Activated 03 When the fourth wireless detectors triggered the SMS message will be Wireless Activated 04 When the fifth wireless detectors triggered the SMS message will be Wireless Activated 05 When the sixth to sixteen wireless detectors triggered the SMS message will be Wireless Activated i i 6 16 When the seventh wire detectors triggered the SMS message will be Wire Activated i i 1 3 for port 1 to 3 alarm 3 you can send message to the unit to rewrite 7 kinds of SMS Every message cannot excess 24 English characters 1234564814 Front door open save first SMS message into the base as first wireless detectors triggered 123456 82 Middle door open save second SMS message into the base as second wireless detectors triggered 123456 83 Back door open save third SMS message into the base as third wireless detectors triggered 123456 84 Front window open g save fourth SMS message into the base as fourth wireless detectors triggered 123456 85 Back window open save fifth SMS message into the base as sixth wireless detectors trig