HI-AW-KNX-1 User`s Manual

image

Contents

1. 12 4 2 4 Swimming pool is available ooooocccccccccccccnccccnnnnnnnnnnn rn 13 SWIPAHWHS DOOlussentaquatppE Sacs Sanibqui qaiquoeR eB ITE i 13 4 2 5 Enable use of extra information objects for Status ccccccceeeeeeeeeeeeeeeeeeeeeees 13 Yutaki S Extra Information eeeeeeeeeeeeee nnns 14 Yutaki S80 Extra Information eeeeeeeeeeeeeee nnne nnns 14 S pechimcal sSpeciedt ONS raies aiaia aaa i ai eiaa aiaa Aiia a aaia Ai 15 6 Compatible Air to Water A W units ssseeeesessseeeeeeennn nnne hne nnn nnns 16 VM EUN m 16 Appendix A Communication objects description table sseeseeeeee mnn 17 O Intesis Software S L All rights reserved URL http www intesis com 4 21 E This information is subject to change without notice n te es i S E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng 1 Presentation EE KNX r P P P 1 E a The HI AW KNX 1 gateways allows fully bidirectional monitoring and i IntesisBox Qu control of the Hitachi Air to Water systems from KNX installations o 3 www intesis com oe The interface is compatible with all the models of the Yutaki S line ar commercialized by Hitachi ce Model HI AW KNX 1 General features e Reduced dimensions easy and fast i
2. 1o01 e r joco m ra sous opera Sate Heat eme 10 omrswen 1o01 fe r joco o 74 stows operan Ste omo ro _orr swen 1001 e r jeomio 7s siaus operation state swmroot rm orr swen roor e r o omron 76 stows operan se mom ro omar 1005 a Joso mom om 7 Status_ Second Ambient Temp 2bytes DPT_Value Temp 9 001 R 79 sous woterinerTenp 2mws rr vawe temp 9001 9 stows weterowettene 2ones OPT vave em 9001 r EUN R MO LH NEN R MON as Extra Information sew water pumo opeaton im omrswan im e r jecomso Sana Dur Gas Te es omen son el s fee Ces saus sue casten eones ovr vue ene sere rf e i EGEE Status_ Defrost Operation DPT_Switch 1 001 a 0 Off 1 On Status Water Pump 1 Operation DPT Switch 1 001 a O Off 1 On O Intesis Software S L Todos los derechos reservados m URL http www intesis com 20 21 Informaci n sujeta a cambios sin previo aviso n te S I S E Email info intesis com IntesisBox es una marca registrada de Intesis Software SL software tel 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng 9 00 14 03 CJ DEUE DEUE DESE DEUE DEUE so R t _ so r so R son al Ir so R soi je 001 R ri DELE PEJE DELE DEUE DELE DELE DETE 9 00 Extra Information Yutaki S80 14 05 00 14 05 14 03 5 00 9 02 n o O O pa w 69 pa m pa pa pa
3. DPT 1 002 1 OTC Mode GRAD is set mn 38 Status C1 Heat OTC Mode Fix DPT_1 002 1 OTC Mode FIX is set g 40 Status C1 Cool OTC Mode Points DPT 1 002 1 OTC Mode POINTS is set ay 4i Status C1 Cool OTC Mode Fix DPT 1 002 1 OTC Mode FIX ts set af 42 Status C1 Thermo Setpoint DPT 9 001 C Figure 4 11 OTC Mode type selection communication objects e Water mode temperatures Using the following communication objects it is possible to control monitorize water setpoint temperatures for the Heat and Cool modes C1 Water Heat Setpoint and C1 Water Cool Setpoint Fd 12 Control C1 Water Heat Setpoint DPT 9 001 C Fa 13 Control C1 Water Cool Setpoint DPT_9 001 C af 44 Status C1 Water Heat Setpoint DPT_9 001 C a 45 Status C1 Water Cool Setpoint DPT 9 001 C Figure 4 12 Water Mode temperatures communication objects o When selecting Air the interface will work for an air climate environment only Air climate control and status objects will be available Water climate control and status objects will be disabled e Air mode temperatures With the communication objects corresponding to this mode enabled control monitoring of the setpoint temperature of the thermo C1 Thermo Setpoint and the ambient temperature provided by a thermostat not included in the Hitachi system C1 Ambient Temp Fd 10 Control C1 Thermo Setpoint DPT 9 001 C a 11 Control_ C1 Ambient Temp DPT 9 001 C 1
4. a 90 Status Outdoor AmbAvg Temp DPT 9 001 C noz Status Inv Oper Freq DPT 14 033 Hz 8752 Status Indoor Exp Valve Opening DPT 5 001 af 93 Status Outdoor Exp Valve Opening DPT 5 001 af 94 Status_ Mixing Valve Position DPT 5 001 mos status Compressor Run Current DPT 9 021 mA Figure 4 23 Extra Information status communication objects e If Yes is selected the installed unit is a Yutaki S80 model the Control Unit Mode and the Status Unit Mode communication objetcs will be hidden and new communication objects will appear providing extra and specific information for the Yutaki S80 e Yutaki S80 Extra Information mos Status_ Disch Gas Temp R1344 DPT 9 001 C 2227 Status Suct Gas Temp R134A DPT 9 001 C af 98 Status_ Liquid Gas Temp R134A DPT 9 001 C a 99 Status Evap Gas Temp R1344 DPT_9 001 5C a 100 Status Disch Pressure R1344 DPT 14 058 Pa m 101 Status Suct Pressure R1344 DPT 14 058 Pa a 102 Status Inv Oper Freq R1344 DPT 14 033 Hz a 103 Status Indoor Exp Valve Open R1344 DPT 5 001 76 a 104 Status Compressor Run Current R134A DPT 9 021 m a 105 Status Error Code R134A 1byte HI error code Figure 4 24 Extra Information for Yutaki S80 status communication objects For more details about the information provided by those comunication objects please check the Hitachi user manual O Intesis Sof
5. 42 Status C1 Thermo Setpoint DPT 9 001 9C 27 43 Status C1 Ambient Temp DPT 9 001 C Figure 4 13 Air mode temperature communication objects o When selecting Full the interface will work for an air and water climate environment Air and Water climate control and status objects will be available O Intesis Software S L All rights reserved URL http www intesis com 10 21 amp This information is subject to change without notice n tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng 4 2 2 2nd circuit C2 is available This parameter enables or disables the Control and Status communication objects of a second circuit or climate zone In case the project is divided into 2 separated circuits this parameter needs to be selected to get control on each circuit independently dE Yes Figure 4 14 2nd circuit parameter detail o When selecting No the gateway will hide the 2nd circuit C2 communication objects o When selecting Yes the gateway will show the the 2nd circuit C2 communication objects Depending on the other selected parameters some objects will remain hidden and some others will be shown e Run and Stop status a 14 Control C2 Run Stop DPT 1 010 0 Stop 1 Run 2 46 Status C2 Run Stop DPT 1 010 0 Stop 1 Run Figure 4 15 2nd circuit Run Stop communicatio
6. Fd 34 Status C1 Run Stop DPT 1 010 0 Stop 1 Run Figure 4 4 C1 circuit Run Stop communication objects This object allows to run or to stop the Hitachi C1 Circuit or C1 climate zone Sending a 0 value will close the C1 circuit while sending a 1 value will open the C1 Circuit More functions related with the C1 circuit and their communication objects can be seen in section 4 2 1 O Intesis Software S L All rights reserved s URL http www intesis com 7 21 This information is subject to change without notice n te es i S E Email info intesis com software tel IntesisBox is a registered trademark of Intesis Software SL 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng e Anti legionella System NOTE The anti legionella function is hidden to users by default Installer can make it available if desired Fd 30 Control AntiLeg Run Stop DPT 1 010 0 Stop 1 Run Fd 3l Control AntiLeg Setpoint DPT 9 001 C Pa 64 Status AntiLeg Run Stop DPT 1 010 0 Stop 1 Run P 65 Status AntiLeg Setpoint DPT_9 001 C Figure 4 5 Anti legionella sysmte communication objects The Hitachi Yutaki S units include an Anti legionella system From the gateway this function can be activated by sending a 1 value to the Control AntiLeg Run Stop object and can be stopped by sending a 0 value to the same object It is also possible to send a value to set the temperature of the Anti legionel
7. I Olojo OoY Uu1 S Co n2 Oo rmmim wojou1 co m joo N2 Oo JU1 S S n O OOo 1 OY U1 S OOo N2 I PS U1 ou 80 80 LCDH linktransmissionerror_________________ In case you detect an error code not listed please contact your nearest Hitachi support center to get more information about the meaning of the error O Intesis Software S L All rights reserved URL http www intesis com 16 21 This information is subject to change without notice n tesi Si Sg ned info intesis com software IntesisBox is a registered trademark of Intesis Software SL 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng Appendix A Communication objects description table Control Objects DATAPOINT TYPE FLAGS OBJECT NUMBER FUNCTION SECTION NAME LONG DPT_NAME DPT_ W T U R Control Unit Mode ibi DPT_Heat Cool 1300 O Cool 1 Heat Control Cx Heat OTC Mode Off ibt oPrBo 1 002 wir Control Cx Heat OTC Mode Points ibt DPT Booi 102 w T Control Cx Heat OTC Mode Grad ibt DPT Booi 102 w T DL g E p g a ID Run Stop 0 Mode 2 14 3 15 1 Set OTC Mode OFF 4 16 1 Set OTC Mode POINTS 5 17 Set OTC Mode GRAD Water Circuit 6 18 Control Cx Heat OTC Mode Fix DPT_Bool 1 002 wir Set OTC Mode FIX Control Cx Cool OTC Mode Off DPT_Bool 1 002 HE Set OTC Mode OFF C1 and C2 7 19 z
8. Through the Status SwimPool Temperature communication object it is possible to read the instantaneous temperature of the Swimming pool system 228 Control SwimPool Run Stop DPT 1 010 0 Stop 1 Run 2723 Control SwimPool Setpoint DPT 9 001 C Fd 61 Status_ SwimPool Run Stop DPT 1 010 0 Stop 1 Run Fd 52 Status SwimPool Setpoint DPT 9 001 C Fd 63 Status_ SwimPool Temperature DPT 9 001 C Figure 4 21 Swimming pool mode communication objects 4 2 5 Enable use of extra information objects for Status These parameters enable or disable the Status communication objects related to the monitoring of extra information depending on the installed Hitachi model Yutaki S or Yutaki S80 o When selecting No the gateway will hide communication objects related with the extra information provided by the Hitachi units o When selecting Yes the gateway will offer you to select extra information for a Yutaki S80 model or the rest of Yutaki S models then select No System is Yutaki 580 Yes Enable use of extra information objects Mo for status Il AZ Figure 4 22 Extra Information parameters detail e If No is selected the installed unit is not a Yutaki S80 model communication objects providing extra information about the Yutaki S models will appear O Intesis Software S L All rights reserved s URL http www intesis com 13 21 This information is subject to change wi
9. 47134 IntesisBox KNX Hitachi A W User s Manual r1 eng 4 2 General dialog In the General Dialog settings tab it is possible to enable disable or modify the parameters shown in Figure 4 1 For instance the first field is showing where you can download the database and the user manual from Download latest database entry for this http www intesis com product and its User Manual from Figure 4 8 Database and User Manual location 4 2 1 System working mode This parameter enables or disables communication objects depending on the working mode selected Water mode Air mode or Full which includes both Water and Air System working made Full Figure 4 9 System working mode parameter details o When selecting Water the interface will work for a water climate environment only Water climate control and status objects will be available Air climate control and status objects will be disabled e OTC Mode The OTC mode Output Temperature Compensation allows keeping the desired indoor temperature despite external temperature variations From the gateway you can Turn this function off by sending a 1 value to the Control C1 OTC Mode Heat Cool Off communication object Fa 3 Control C1 Heat OTC Mode Off DPT 1 002 1 Set OTC Mode OFF Mn T Control C1 Cool OTC Mode Off DPT 1 007 1 5et OTC Mode OFF Pi 35 Status Cl Heat OTC Mode Off DPT 1 002 1 OTC Mode OFF is set Fd 39 Status C1 Cool OTC Mode Of
10. 6 3 EN 60950 1 EN 50491 3 EN 50090 2 2 EN 50428 EN 60669 1 EN 60669 2 1 From 0 C to 40 C Isolation voltage Certifications External Power Supply connection i KNX port Phys Addr KNX KNX programming LED s B prog g 70 mm P intesiSBox PROG t4 KNX programming button 01 i i H LINK H Link port 2 KNX CE Model H AW KNX 1 Code Xxxxxxxx amp 28 mm 70 mm O Intesis Software S L All rights reserved s URL http www intesis com 157721 This information is subject to change without notice n te es S E Email info intesis com software tel IntesisBox is a registered trademark of Intesis Software SL 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng 6 Compatible Air to Water A W units A list of Hitachi unit model references compatible with HI AW KNX 1 and their available features can be found in http www intesis com pdf IntesisBox HI AW xxx 1 AC Compatibility pdf 7 Error Codes KNX Error Remote Controller Error Error Description Code ie HE Except for Alarm Code 41 42 HEN 06 L 07 08 cus O 2 P d5 16 L 17 24 ESSE a 42 5 EEN 55 59 b EET 70 E O EN NE 8 O 74 E 8 38 Freeze Protection Stop by indoor liquid temperature thermistor NININININININIMI o uulu ual al elel AIAI wU IVI IWwWININININ e jejejejejeje
11. Air to Water Yutaki S series Application s Program Version 0 2 Reference HI AW KNX 1 O Intesis Software S L All rights reserved URL http www intesis com E This information is subject to change without notice n te es i S E Email info intesis com software t IntesisBox is a registered trademark of Intesis Software SL el 34 938047134 3 21 IntesisBox KNX Hitachi A W User s Manual r1 eng INDEX PP ro UE UE pd la p o o PI O EMISIT MIR dE 5 An E OU A 6 25 Inistallato ana SOUND sais aa 6 4 ETS parameters and communication objects 0oocccccccccccccccnccccnnnnnnnnnnn nn nn nn nr 7 MD UA Cli A E o CEE ER E O o O V EFIE 7 Run or Stop the Ulsa rn naaa 7 Change de Unit mode sssssssssssssssssnssnssssnssssnssrnnesrnnessnnesnsnesnsnesnsneenssennenenne 7 RUnoOr Stop the El Cross 7 Anti legionella SS Mirror IRAN 8 KNX Menu DIOCKING israel 8 EPT ana NOS no 8 42 General dO asar nara 9 AZ SYSTEM WOFKING MOI Erann tanta tender sao eariaa nests 9 SIApSSc 9 Water mode temperatures eeeesseseeeeeeennnn rr ann n nana rh nn nnn 10 Air mode temperatures ccesssssseeeee rr rr haa nnn anm ahhh nnn a a nnn nn nn 10 4 2 2 2nd circuit C2 is available sssseeeeeeeseeeee nennen nhan nn nnn nnn 11 4 2 3 DHW is available Domestic Hot Water sseesssseeeeenn mnn nnns 12 Domestic IO WATO MT TTT H
12. Control Cx Cool OTC Mode Points wir Set OTC Mode POINTS 9 21 Control Cx Cool OTC Mode Fix wir X can be 1 or 2 depending on which circuit is being controlled 8 20 1 Set OTC Mode FIX C Between 0 C and 35 C C Between 20 C and 40 C Intesis Software S L Todos los derechos reservados m URL http www intesis com 17 21 Informaci n sujeta a cambios sin previo aviso n te S S E Email info intesis com IntesisBox es una marca registrada de Intesis Software SL software tel 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng on M M G RI DR IRR DER M ns ora mese oo or von s eem mm ICC IE EM Control SwimPool Run Stop DPT Start 1 010 E Swimming pool od Control SwimPool Setpoint 2 bytes DPT Value Temp 9 001 wir oC Between 249C and 339C EM Control AntiLeg Run Stop DPT Start 1 010 AntiLeg EM Control AntiLeg Setpoint 2 bytes DPT Value Temp 9 001 KNX Block omo Control KNX Blocks Enables Menu DPT Enable 1 003 O Stop 1 Run oC Between 509C and 759C O Blocks 1 Enables O Intesis Software S L Todos los derechos reservados m URL http www intesis com 18 21 Informaci n sujeta a cambios sin previo aviso n te S I S E Email info intesis com IntesisBox es una marca registrada de Intesis Software SL software tel 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng Status Objects DATAPOINT TYPE FLAGS NAME LONG DPT
13. Sj IntesisBox HI AW KNX 1 User s Manual Issue date 09 01 2013 rl eng Intesisg IntesisBox KNX Hitachi A W User s Manual r1 eng Intesis Software S L 2012 All Rights Reserved Information in this document is subject to change without prior notice The software described in this document is furnished under a license agreement or nondisclosure agreement The software may be used only in accordance with the terms of those agreements No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or any means electronic or mechanical including photocopying and recording for any purpose other than the purchaser s personal use without the written permission of Intesis Software S L Intesis Software S L Mila i Fontanals 1 bis 08700 Igualada Spain TRADEMARKS All trademarks and trade names used in this document are acknowledged to be the copyright of their respective holders Information in this document is subject to changes without prior notice O Intesis Software S L All rights reserved URL http www intesis com 2 21 E This information is subject to change without notice n te es S E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng Interface for the integration of Hitachi s Air to Water units into KNX TP 1 EIB control systems Compatible with
14. _NAME DPT_ID R WT U OBJETO NUMBER SECTION FUNCTION Mode O Cool 1 Heat 1 01 O Stop 1 Run m 1 00 OTC Mode Off Set m oO of of of eB nin E 1 00 OTC Mode POINTS Set 1 00 OTC Mode FIX Set nm 1 00 OTC Mode Off Set 1 00 OTC Mode Off Set 1 00 OTC Mode POINTS Set 1 00 OTC Mode FIX Set 9 00 9 00 9 00 9 00 1 01 O Stop 1 Run DHW 9 00 O O 9 00 1 01 O Stop 1 Run Swimming pool 9 00 9 00 ESEIEREIEIEIEIEIEIEIEIEIERIERIEIEIEIEIES O O X can be 1 or 2 depending on which circuit is being observed O Intesis Software S L Todos los derechos reservados m URL http www intesis com 19 21 Informaci n sujeta a cambios sin previo aviso n te S S E Email info intesis com IntesisBox es una marca registrada de Intesis Software SL software tel 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng ea sous anos ruso iw orson roro a Jr osos AntiLeg es sous antes sapo zones mme m 90 e m fe SEI ce oaeen tot orree 1 003 e rp jocsexic ee eoraro o seus tron i omm e 8 r ononon rnam DAMM e ene zm enumera 8 0 no erori Othervauensee7_ 9 sians operaton Sure umtomon 10 omm roor e r o omeon 7e stows operan Se Coor Demens roe orrsmen 1001 a r jeomion i siaus operation state coo meme rw orr swen roor e T eoero 7a sous opera Sate Heat emana 10 oerswen
15. control its setpoint temperature Through the Status DHW Temperature communication object it is possible to read the instantaneous temperature of the DHW system 2726 Control DHW Run Stop DPT 1 010 0 Stap 1 Run 8777 Control DHW Setpoint DPT 9 001 C a 38 Status DHW Run Stop DPT 1 010 0 Stop 1 Run a 99 Status DHW Setpoint DPT_9 001 C a 60 Status DHW Temperature DPT_9 001 C Figure 4 19 DHW mode communication objects Intesis Software S L All rights reserved s URL http www intesis com 12 21 This information is subject to change without notice n te es i S E Email info intesis com software tel IntesisBox is a registered trademark of Intesis Software SL 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng 4 2 4 Swimming pool is available This parameter enables or disables the Control and Status objects corresponding to the control and monitoring of a swimming pool system present in the project Swimming pool is available Yes Figure 4 20 Swimming pool parameter details o When selecting No the gateway will hide communication objects related with the swimming pool o When selecting Yes the gateway will show communication objects related with the swimming pool e Swimming pool By means of Contro SwimPool Run Stop and Control SwimPool Setpoint it is possible to turn on off the Swimming pool system and also to control its setpoint temperature
16. ettings When importing the ETS database for the first time the following menu appears with these parameter values selected as default Settings z Download latest database entry for this http www intesis com product and its User Manual from System working mode Full 2nd circuit C2 is available No X DHW is available No Domestic Hot Water Swimming pool is available No Enable use of extra information objects No for status A Figure 4 1 Parameter values by default With this configuration is possible to control the system Control objects and monitoring it Status objects through the following communication objects e Run or Stop the unit lo Control Unit Run Stop DPT 1 010 0 Stop 1 Run Figure 4 2 Run Stop communication objects This object allows to run or to stop the Hitachi unit features C1 C2 DHW and or SwimPool at once Sending a O value will turn them off while sending a 1 value will turn them on e Change de Unit mode 2 1 Control Unit Mode DPT_ 1 100 0 Cool 1 Heat E 33 Status Unit Mode DPT 1 100 0 Cool 1 Heat Figure 4 3 Unit mode selection communication objects This object allows changing the working mode of the Hitachi unit Sending a 0 value the unit will turn into Cool mode while sending a 1 value will make the unit turn into Heat mode e Run or Stop the Ci Circuit 272 Control C1 Run Stop DPT 1 010 0 Stop 1 Run
17. f DPT 1 002 1 OTC Mode OFF is set Figure 4 10 OTC Mode Off communication objects Activate the different modes available for the calculus of the water temperature for the cooling or heating the facility where the unit is placed Points User fixes 4 points that will create a line function that will depend on the current ambient temperature Gradients In this case the function used is not a line but a gradient Only available for the Heat mode Fix The temperature adjustment is only performed by a fixed value This makes the unit to keep this fixed value all the time m4 Control Cl Heat OTC Mode Points DPT 1 002 1 Set OTC Mode POINTS Fd 3 Control C1 Heat OTC Mode Grad DPT 1 002 1 Set OTC Mode GRAD Fd 5 Contro Heat OTC Mode Fix DPT 1 002 1 Set OTC Mode FIX 2 amp Contro Cool OTC Mode Points DPT 1 002 1 Set OTC Mode POINTS C CI O Intesis Software S L All rights reserved URL http www intesis com 9 21 E This information is subject to change without notice n tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng EN 9 Control C1 Cool OTC Mode Fix DPT 1 002 1 Set OTC Mode FIX Fd 10 Control C1 Thermo Setpoint DPT 9 001 C 2 36 Status C1 Heat OTC Mode Points DPT 1 002 1 OTC Mode POINTS is set Pa 37 Status C1 Heat OTC Mode Grad
18. la system to this value To do it so you have to use the Control Antileg Setpoint object A IMPORTANT Anti legionella will set the water temperature to the setting value during the specified time This temperature will be dangerous to the user and could burn him or her Installer is responsible for configuring it properly advising the user and enabling the function e KNX menu blocking Fd 32 Control KNX Blocks Enables Menu DPT 1 003 0 Block 1 Enable Fd 66 Status KNX Blocks Enables Menu DPT 1 003 0 Block 1 Enable Figure 4 6 KNX menu communication objects This object allows blocking or enabling the KNX menu from Hitachi s LCD panel Sending a 0 value will block the Menu while sending a 1 value will enable the Menu e Errors and Alarms 2 67 Status Error Alarm DPT 1 005 0 No alarm 1 Alarm 2 68 Status Error Code 2byte 0 No error Any other see man Figure 4 7 Errors and alarms communication objects These objects allows reading the system status indicating if any alarm or error is active Status Error Alarm and in case it exist it indicates which error is Status Error Code See section 7 to get more information about the error codes O Intesis Software S L All rights reserved URL http www intesis com 8 21 E This information is subject to change without notice n tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 9380
19. n objects To activate or deactivat the 2nd circuit C2 a 1 value or a 0 value needs to be sent respectively to the Run stop communication object e If Water mode is selected Fa 15 Control C2 Heat OTC Mode Off DPT_1 002 1 Set OTC Mode OFF a 16 Control C2 Heat OTC Mode Points DPT 1 002 1 Set OTC Mode POINTS m 17 Control C2 Heat OTC Mode Grad DPT 1 002 1 Set OTC Mode GRAD 27 18 Control C2 Heat OTC Mode Fix DPT 1 002 1 Set OTC Mode FIX 2 19 Control C2 Cool OTC Mode Off DPT 1 002 1 Set OTC Mode OFF 8 20 Control C2 Cool OTC Mode Points DPT 1 002 1 Set OTC Mode POINTS 1721 Control C2 Cool OTC Mode Fix DPT 1 002 1 Set OTC Mode FIX 2 24 Control C2 Water Heat Setpoint DPT 8 001 C 2 25 Control C2 Water Cool Setpoint DPT 9 001 C 2247 Status C2 Heat OTC Mode Off DPT 1 002 1 OTC Mode OFF is set 8248 Status C2 Heat OTC Mode Points DPT 1 002 1 OTC Mode POINTS is set 849 Status C2 Heat OTC Mode Grad DPT 1 002 1 OTC Mode GRAD is set Fd 50 Status C2 Heat OTE Mode Fix DPT 1 002 1 OTC Mode FIX is set Fd 91 Status C2 Cool OTC Mode Off DPT 1 002 1 OTC Mode OFF ts set Fad 524 Status C2 Cool OTC Mode Points DPT 1 002 1 OTC Mode POINTS is set m 53 Status C2 Cool OTC Mode Fix DPT 1 002 1 OTC Mode FIX is set m 96 Status C2 Water Heat Setpoint DPT_9 001 PC EY 37 Status C2 Water Cool Setpoint DPT 9 001 C Figure 4 16 2nd circuit Wate
20. nstallation e Multiple control and status objects bit byte characters with standard KNX datapoints e One status object available for each control object e Control on the A W unit based on the ambient temperature read from the unit itself or from the temperature read by any KNX thermostat e The Hitachi A W can be controlled simultaneously through the remote controller of the A W system or through the KNX bus e Total supervision and control of the Hitachi A W unit from KNX including unit internal variables supervision special modes control such as Anti legionella and error alarm and codes too O Intesis Software S L All rights reserved URL http www intesis com 5 21 E This information is subject to change without notice n te es i S E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng 2 Connection Connection of the interface to the AW indoor unit is by means of the cable supplied with the indoor unit to connect the remote controller lt must be connected to the interface in one side connector H Link and to the internal electronic board of the Air to Water indoor unit in the other side Connection of the interface to the KNX bus is by means of the standard KNX bus connector also supplied with the interface In order to plug the interface to the external power supply two different meth
21. ods are available First one is using the external power supply provided with the interface using the DC JACK connector Connections diagram Power Supply KNX TP 1 M Bus EIB 2 wire terminal B 2 o pr med as ME rr O p DC Jack ue KNX CE Model HI AW KNX 1 ode XXXXXXXX IMPORTANT Connect only one external power supply Use either the two wire HI AW KNX 1 H Link Max 1000 m terminal connector A or the DC adaptor Jack connector B Hitachi Yutaki 3 Installation and setup This is a fully compatible KNX device that must be configured using the ETS software The ETS database can be downloaded from http www intesis com down eib HI AW KNX 1 zip Please check the README txt file located inside the zip file to find instructions for proper installation of the database A IMPORTANT Do not forget to select the corresponding features of the Air to Water system connected to the HI AW KNX 1 interface This should be selected in the Parameters section on the ETS software Intesis Software S L All rights reserved URL http www intesis com 6 21 amp This information is subject to change without notice n te es i S E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng 4 ETS parameters and communication objects 4 1 Default s
22. pa pa pa pa pa pa pa o o o O O o o o o o o O O WA Ill No error Other values see 7 O Intesis Software S L Todos los derechos reservados m URL http www intesis com 21 21 Informaci n sujeta a cambios sin previo aviso n te S I S E Email info intesis com IntesisBox es una marca registrada de Intesis Software SL software tel 34 938047134
23. r Mode communication objects O Intesis Software S L All rights reserved s URL http www intesis com 11 21 This information is subject to change without notice n te es i S E Email info intesis com IntesisBox is a registered trademark of Intesis Software SL software tel 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng e If Air mode is selected 1 22 Control C2 Thermo Setpoint DPT 9 001 9C 2223 Control C2 Ambient Temp DPT 9 001 C m 54 Status C2 Thermo Setpoint DPT 9 001 9C BY 33 Status C2 Ambient Temp DPT 9 001 C Figure 4 17 2nd circuit Air Mode communication objects e If Full mode is selected all communication objects present when selecting Water or Air will be enabled for this mode too 4 2 3 DHW is available Domestic Hot Water This parameter enables or disables the Control and Status objects corresponding to the control and monitoring of a water tank or DHW system DHW is available Yes Domestic Hot Water D Figure 4 18 DHW Parameter detail o When selecting No the gateway will hide communication objects related with the water tank or the Domestic Hot Water system o When selecting Yes the gateway will show the communication objects related with the water tank or the Domestic Hot Water system e Domestic Hot Water By means of Control_ DHW Run Stop and Control DHW Setpoint it is possible to turn on off the DHW system and also to
24. thout notice n te es i S E Email info intesis com software tel IntesisBox is a registered trademark of Intesis Software SL 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng e Yutaki S Extra Information E 69 Status_ Operation State Unit On Off DPT 1 001 0 Off1 On m 70 Status Operation State Cool Demand DPT 1 001 0 Off 1 On a 71 status Operation State Cool Thermo DPT 1 001 0 OfF1 On 8772 Status Operation State Heat Demand DPT 1 001 0 Off1 On ay 73 Status_ Operation State Heat Thermo DPT 1 001 0 Off 1 On 8774 Status Operation State DHW DPT 1 001 0 Ofr 1 On 8775 Status Operation State SwimPool DPT 1 001 0 Off1 On E 76 Status Operation State Alarm DPT 1 005 0 No alarm 1 Alarm 8777 Status Outdoor Ambient Temp DPT 9 001 C 8778 Status Second Ambient Temp DPT 9 001 C 8779 Status Water Inlet Temp DPT 9 001 C 2 80 Status Water Outlet Temp DPT 9 001 C a 61 Status_ Defrost Operation DPT 1 001 0 Off1 On 2 82 Status Water Pump 1 Operation DPT 1 001 0 Off1 On 27 63 Status Water Pump 2 Operation DPT 1 001 0 Off1 On a 04 Status Water Pump 3 Operation DPT 1 001 0 OfF1 On a 85 Status_ Disch Gas Temp DPT_9 001 C a 66 Status Suct Gas Temp DPT 9 001 C a 67 Status Gas Temp THMg DPT 93 001 C a 66 Status Liquid Temp THMI DPT 9 001 C a 69 Status Water Outlet Temp 3 DPT_9 001 C
25. tware S L All rights reserved URL http www intesis com 14 21 E This information is subject to change without notice n te es i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 IntesisBox KNX Hitachi A W User s Manual r1 eng 5 Technical Specifications Enclosure ABS UL 94 HB de 2 5 mm thick 70 X 70 X 28 mm 70g Ivory White Power supply 29V DC 6MA KNX bus 10 40V DC 100mA Recommended 12V DC 100 mA External Power Supply Must use a NEC Class 2 or Limited Power Source LPS and SELV rated power supply Plug in terminal block for power connection 2 poles Per terminal solid wires or stranded wires twisted or with ferrule Terminal wiring for core 0 5mm2 2 5mm2 power supply and low voltage signals 2 cores 0 5mm2 1 5mm2 3 cores not permitted KNX port 1 x KNX TP1 EIB port opto isolated Plug in terminal block 2 poles TNV 1 H Link port Plug in terminal block for H Link bus connection 2 poles with no polarit LED indicators 1 x KNX programming 1 x KNX programming Configuration Configuration with ETS Operating Temperature Storage Temperature From 0 C to 40 C Operating Humidity 25 90 at 50 C non condensing External Power Supply KNX 2500V External Power Supply H Link 1500V CE conformity to EMC directive 2004 108 EC and Low voltage directive 2006 95 EC EN 61000 6 2 EN 61000