1. Setting Up the Terminal AXEL The parameters are Active Interface Two possible values Ethernet The rest of the parameters are disabled Wireless Connection and security settings are requested Other parameters See Chapter 2 2 3 for more information 2 1 3 Network Connection The Network dialog box is shown below Terminal DHCP DHCP DHCP DHCP Server The parameters are Enable DHCP two options Yes the DHCP protocol is run when the set up is exited and the terminal automatically obtains an IP address and various other DHCP options netmask default router etc No a Static IP address is required IP address mandatory if DHCP is disabled Default router optional router IP address 1st DNS Server IP Address optional DNS server IP address Server Name not available for Citrix DNS name if the DNS server is known or a simple mnemonic name A name must be entered Server IP address not available for Citrix if this field is left blank DNS will be used to resolve the hostname TCP Port only for VNC VNC session number Note for a Virtual Desktop session the server is the Connection Broker 12 AX3000 Using and Configuring the models 75D amp 85 AXEL Setting Up the Terminal 2 1 4 Devices This box is displayed for the all networked session types Quick Set Up Printer USB Drives Disabled NEXT These parameters are Printer Connected auxi
2. 1 2 3 Print and Terminal Server The AX3000 auxiliary ports can be managed either By a network service LPD or PRT5250 for printers TELNET CLIENT for serial terminals or TTY for other peripherals By escape sequences compatible with serial terminals Slave mode AX3000 Using and Configuring the models 75D amp 85 5 Introduction to the AX3000 AXEL 1 2 4 Tools and Statistics Embedded AX3000 tools provide the following features Ping Remote set up Network Statistics Firmware downloading 6 AX3000 Using and Configuring the models 75D amp 85 AXEL Setting Up the Terminal CHAPTER 2 SETTING UP THE TERMINAL AX3000 Using and Configuring the models 75D amp 85 7 Setting Up the Terminal AXEL This chapter describes quick set up and interactive set up features Two configuration methods are available When the AX3000 is powered up for the first time Quick Set Up wizard Or at any time through the interactive set up 2 1 FIRST POWER ON When the terminal is switched on up for the very first time two configuration methods are available Quick Set Up a wizard allows the terminal to be set up in few seconds for typical use Auto Configuration used in conjunction with AxRM this function allows the terminal to automatically receive new firmware and or a configuration IMPORTANT the auto configuration must use the Ethernet interface The quick set up is designed for a typical simple enviro
3. 85 AXEL Setting Up the Terminal These parameters are Connection Type Selected in previous dialog box Exploration Protocol possible values are TCP IP HTTP XML based exploration TCP IP UDP based exploration TCP Port used by the exploration protocol IP Address or DNS Name location of a server farm overwrite default of ica if necessary Published Application or Published Server press F2 to show the list from the Citrix farm 2 1 7 Serial Connection Note Depending on model if an AUX1 port is available on the terminal rear panel this is the main port if not a third party USB COM adaptor is requested Note this component is not supplied by Axel Where the session type is Text Emulation and connection type is aux1 the following box is displayed 38400 8 1 No XON XOFF 11h 13h Printer Parallel These parameters are Speed press Space to select the baud rate Format press Space to select the data format Handshake for reception press Space to select the handshake Default Port auxiliary port used for local printings AX3000 Using and Configuring the models 75D amp 85 15 Setting Up the Terminal AXEL 2 1 8 Set Up Summary At the end of the wizard process a summary of the selected settings is displayed For example Summary Terminal French axel2C0O07B TSE rdp TCP IP No 192 168 1 247 Zhho nn ehh B 192 168 1 165 Printer None USB Drives D
4. Aux1 Aux2 PARA parallel Usb1 Usb4 Neti and Net2 Service and Other information about the associated network service Ipd printer port name and optional filter rcmd printer port name telnet associated host TCP port TERM and connection flags tty associated host TCP port and connection flag prtb250 associated host TCP port printer name and AS 400 connection status printd or rtty TCP port and optional filter State see above for the possible values A connection can be manually closed by selecting the CLOSE CONNECTION button Note to refresh the information displayed select the REFRESH button 9 2 2 TCP Server and TCP Client Connection Information To go further with connection information two additional statistics dialog boxes are available TCP server contains information about connections where the AX3000 is acting as a server Ipd rtty and remd TCP client contains information about connections where the AX3000 is acting as a client telnet tty rdp ica and vnc These statistics show the following Information about connections Values of counters These dialog boxes are accessed by the Diagnostics Statistics TCP xxx yyy menu 40 AX3000 Using and Configuring the models 75D amp 85 AXEL Tools and Statistics Example of a Connection box TCP Client Statistics CONNECTIONS STATE Who Type State Local Socket Remote Socket
5. and type the network interface useful when set in auto sense mode IP parameters IP address netmask and default router FQDN terminal full name b DHCP DNS The DHCP DNS box is the following DHCP Client DNS Server Update by the Terminal cA REFRESH In the above dialog box the following information is given State the current DHCP state The possible states are selecting searching a DHCP server broadcast requesting requesting an IP address from the DHCP server which answered selecting bound search has been successfully completed IP address has been set free DHCP protocol is not enabled or DHCP protocol failed renewing renewing the leased IP address to the DHCP server which answered selecting rebinding renewing the leased IP address to any DHCP server broadcast DHCP Server IP address of the DHCP server Lease Time seconds amount of time of the leased IP address For BOOTP protocol the value is infinity Remaining Lease remaining time before lease expires For BOOTP protocol the value is infinity AX3000 Using and Configuring the models 75D amp 85 43 Tools and Statistics AXEL Update Type information about the DNS server update when updated by the terminal Main values are None no update Direct Reverse both types are done by the terminal Direct Reverse by DHCP direct update done by the terminal and reverse update done by the D
6. 5 AXEL Setting Up the Terminal Protected Access is Enterprise EAP Security Enterprise EAP LEAP AES CCMP Authentication Authentication Mode Data Encryption Authentication requested LEAP AES CCMP yes TKIP yes PEAP MS CHAP v2 AES CCMP yes TKIP yes Notes See previous protected access mode for WPA WPA2 protocols Both username and password must be entered Protected Access is 802 1X Security Authentication Authentication Mode Data Encryption Authentication requested LEAP WEP yes PEAP MS CHAP v2 WEP yes Note Both username and password must be entered AX3000 Using and Configuring the models 75D amp 85 23 AXEL Using the AX3000 CHAPTER 3 USING THE AX3000 AX3000 Using and Configuring the models 75D amp 85 25 Using the AX3000 AXEL This chapter covers use of the AX3000 3 1 SWITCHING ON THE AX3000 The following operations are performed when the terminal is turned on Boot initialization Network interface if DHCP enabled wait for network is available plugged cable for Ethernet or Access Point connection for wireless TCP IP if DHCP enabled wait for IP address and other parameters is received Auto configuration optional checks over the network if a new firmware configuration is available If yes the terminal reboots again for the new firmware configuration to take effect Auto
7. AXEL Platine Terminal AX3000 Models 75D amp 85 ADDENDUM September 2009 Ref AX3 WIFI E 2 The reproduction of this material in part or whole is strictly prohibited For additional information please contact AXEL 14 Avenue du Qu bec B t K2 EVOLIC BP 728 91962 Courtaboeuf cedex FRANCE Tel 33 1 69 28 27 27 Fax 33 1 69 28 82 04 Email info axel com The information related to firmware 0922a in this document is subject to change without notice AXEL assumes no responsibility for any errors that may appear in this document All trademarks and registered trademarks are the property of their respective holders 2009 AXEL All Rights Reserved TABLE OF CONTENT INTRODUCTION ri a c ob sz ud Ga Ga naut cu uh nt Ca npa ad uni nt ud sede cai cu ni due ne aa DA Cinta ti 1 1 INTRODUCTION TO THE AXS3O0OQ eeeeeeeren ener 3 1 1 7 TERMINAE MODELS iii caiacs d nk d c e d n on d re ed nt dd da 4 1 2 MAIN FU NGTIORNS iiri itor nh rnm tr n er nd RR ta diada er 5 1 2 1 Network FUNCTIONS cccccccecececeeeeececeececececececececscececececececececececececececess 5 1 2 2 Terminal PUACHON sis iii vieioselatessasbeshedvevevensiesdatersedesesievesstoasioasd 5 1 2 8 Print and Terminal Server ou ccccccccccccccececececececececececececececececeeeeerenenenaess 5 1 2 4 Tools and Statistics ion dd t te iesu das ioa 6 2 SETTING UP THE TERMINAL leeeeeeeeeee eese eene an
8. Connection some connections may be opened automatically Screen sessions if the auto connection parameter is set to yes Auxiliary port sessions if the associated service is a client service tty telnet or prt5250 and if the auto connection parameter is set to yes If multiple screen sessions are auto connected the first active screen session is displayed Session Manager if no screen session is connected the Session Manager is displayed Two modes are available Classic mode Desktop mode The following chapter covers the session manager modes 26 AX3000 Using and Configuring the models 75D amp 85 AXEL Using the AX3000 3 1 1 Session Manager Classic Mode This is the appearance of the classic mode AXEL Ultra Thin Client www axel com Copyright AXEL The following information is displayed for each session The associated keystroke For example Alt F1 The session label For example 1 TSE or 2 5250 The server To open a session the user presses the associated keystrokes AX3000 Using and Configuring the models 75D amp 85 27 Using the AX3000 AXEL 3 1 2 Session Manager Desktop Mode This is the appearance of the Desktop Mode The following information is displayed for each session An icon The indicator and the session label For example 1 TSE or 2 5250 Note whatever the status line settings with the session manager the status line is always di
9. HCP server Status the possible update values are None no update not requested Done update succeeded Failed update failed Pending update in progress Dhcp update done by the DHCP server the terminal had been informed to forgive the update c Statistic The statistics box is the following Correct Frames Errors Input Output REFRESH Correct Frames Output and Input are the number of correct frames transmitted and received Errors this section gives the type and the number of errors No errors should be shown in a good working environment healthy network 44 AX3000 Using and Configuring the models 75D amp 85 AXEL Tools and Statistics 4 3 2 Wireless Interface a State The following information is displayed when selecting the Configuration Network Wireless Interface State menu SSID AXNETGEARO Connection IP Parameters Other Information lt Space gt lt Space gt REFRESH DISCONNECT Note this box information is automatically updated every 5 seconds To force an update use the REFRESH button When the wireless interface is connected the 802 11 information available is BSSID access point MAC address Link protocol and current speed Signal power reception Channel channel number and frequency AX3000 Using and Configuring the models 75D amp 85 45 Tools and Statistics AXEL b DHCP DNS The DHCP DNS box is similar than Ethernet one
10. ND The ping command is used to check for the presence of a live TPC IP device Select the Diagnostics Ping dialog from the AX3000 set up then enter the IP address or the name of the TCP IP peripheral 4 2 CONNECTION MANAGEMENT Connection failures are often caused by incorrect settings 38 AX3000 Using and Configuring the models 75D amp 85 AXEL Tools and Statistics 4 2 1 Global Connection List Select the Diagnostics Connections dialog to check the status of all defined connections Connections Server Host IP Addr Port Miscellaneous AUXILIARY PORTS Port Service State Other Information REFRESH CLOSE CONNECTIONS Note outside the set up use Ctrl Alt X displays this box For each session the following information is displayed No session number Type main values are TSE ica telnet tty vnc State the possible values are Established the session is connected Closed the session has ended Syn sent connection request in progress Time Wait connection close in progress Server and IP Addr Host the associated host Port the TCP port used for the session this is usually 23 for telnet 2048 for tty and 59xx for vnc Configuration the associated pre defined configuration AX3000 Using and Configuring the models 75D amp 85 39 Tools and Statistics AXEL For each auxiliary port the following information is displayed Port the name of the port
11. Parameters Sessions Wireless Interface gt State Servers The key points of the AX3000 network configuration are General Parameters terminal identification and interface activation Interface Ethernet or Wireless static or dynamic IP address DNS protocol and router management AX3000 Using and Configuring the models 75D amp 85 17 Setting Up the Terminal AXEL 2 2 1 General Parameters To set the AX3000 interface and the terminal identification select the Configuration Network General Parameters menu The dialog box below is displayed axel2CO0 B Ethernet Default DNS Domain The Active Interface parameter selects which interface to used Possible values are Ethernet Wireless None serial mode 18 AX3000 Using and Configuring the models 75D amp 85 AXEL Setting Up the Terminal 2 2 2 Ethernet Interface To set the Ethernet interface properties select the Configuration Network Ethernet Interface IP Parameters menu The dialog box below is displayed Ethernet Interface 00 00 34 2C 00 7B Interface Auto Sense No 192 168 1 247 Co Routers lt Space gt Note the Ethernet address is displayed as the title box 2 2 3 Wireless Interface To set the Wireless interface properties select the Configuration Network Wireless Interface menu The two sub menus are Wireless Parameters see next page IP Parameters same dialog box as Ethernet inter
12. Rev Q Snd Q REFRESH Description of the information given within this box Who AX3000 resource involved in the connection S1 session 1 S8 session 8 Aux1 Aux2 PARA parallel Usb1 Usb4 Net1 and Net2 Type network service being used telnet tty etc State the possible values are Established the session is connected Closed the session has ended Syn sent connection request in progress Time Wait connection close in progress Local Socket IP address and TCP port for the AX3000 Remote Socket IP address and TCP port for the host Rev Q number of bytes received by the AX3000 and not yet processed Snd Q number of bytes not yet sent to the host AX3000 Using and Configuring the models 75D amp 85 41 Tools and Statistics AXEL Example of a Counter box TCP Client Statistics GENERAL ERRORS REFRESH 4 3 INTERFACE INFORMATION 4 3 1 Ethernet Interface a State The following information is displayed when selecting the Configuration Network Ethernet Interface State menu Ethernet Interface Connection IP Parameters Other Information lt Space gt lt Space gt REFRESH Note this box information is automatically updated every 5 seconds To force an update use the REFRESH button 42 AX3000 Using and Configuring the models 75D amp 85 AXEL Tools and Statistics In the above dialog box the following information is given Link speed
13. SSIONS AXEL terminals provide multiple and concurrent connections This feature allows simultaneous access to multiple hosts and applications 3 3 1 Opening and Switching Sessions Opening or switching sessions can be done through The keyboard press lt Alt gt lt Fx gt These default keystrokes can be changed The mouse click left With the session manager desktop mode click onto a session icon With the status line click the session label The status line must be enabled Note if the session is host free a dialog box is displayed The following parameters are required Connection Type read only information Host press lt Space gt to select the host TCP Port the default value is protocol dependent 30 AX3000 Using and Configuring the models 75D amp 85 AXEL Using the AX3000 3 3 2 Disconnecting Sessions A session can be disconnected by one of two ways A system command i e logging off the server Example under Unix exit or lt Ctrl gt lt D gt Ctrl Alt D This keystroke is locally processed by the AX3000 and works regardless the operating system If the user closes the current session lt Ctrl gt lt D gt in UNIX the behavior of the terminal depends on how the auto reconnection parameter is set for the current session If this parameter is set to yes a new connection is immediately and automatically established within the current session If this para
14. Use the standard Paste function For example lt Ctrl gt lt V gt To a VNC Session The vncconfig tool must be run Select Paste in the contextual menu of the Linux software To a Text Session 5250 3270 ANSI VT WYSE Press lt Ctrl gt lt V gt with 5250 and 3270 emulations or lt Ctrl gt lt Alt gt lt V gt with other emulations to paste the contents of the local clipboard Note for the 5250 and 3270 sessions a Field Exit function is sent at the end of each line contained in the clipboard 3 6 TURNING OFF THE AX3000 A careful check should be made before turning off the TCP IP AX3000 if TCP IP connections are active The operating system cannot detect if a TCP IP device is turned off so the current TCP IP connections remain active as far as the server is concerned resulting in various potential issues AX3000 Using and Configuring the models 75D amp 85 33 Using the AX3000 AXEL Under UNIX it is advisable not to turn off the TCP IP AX3000 when a login prompt is displayed something which is commonly done with serial UNIX terminals This is because a telnet connection has been opened and will then become an orphan process The following examples illustrate how the TCP IP AX3000 differs from a conventional dumb terminal f the auto reconnect parameter if set to yes a stable stage cannot be reached on the AX3000 New telnet connections will repeatedly be opened Under OS 400 it is impossible
15. bpp 16bpp 16bpp 16bpp Connectors Parallel Port 1 1 1 ae 1 1 Serial port 2 2 2 2 2 USB Port 2 4 2 2 2 2 Other USB Driver yes yes Firmware Option MSC Smartcard yes yes Firmware Option SCA Audio USB USB 4 AX3000 Using and Configuring the models 75D amp 85 AXEL Introduction to the AX3000 1 2 MAIN FUNCTIONS 1 2 1 Network Functions The Axel terminal supports the following network functions DHCP obtaining an IP address and other parameters DNS publishing the terminal name and resolving server names Routing WAN connection In addition for the AX3000 M75D amp M85 there is a choice of the active interface either Ethernet or Wireless Only one interface can be active but each provides its own IP settings DHCP DNS routers 1 2 2 Terminal Function Each TCP IP AXEL terminal can support up to six concurrent and independent sessions This multi session capability provides multiple connections across a network Each session can Connect to any TCP IP networked server Use different protocols ica vnc rdp telnet ssh and tty Have independent parameters resolution emulation etc Programmable keystrokes are used to open or hotkey between sessions The maximum number of sessions is 6 but this can be limited to fewer sessions Minimum 1 Note the AX3000 can also act as a RS232 serial terminal
16. c Statistic The statistics box is the following Correct Frames Errors Input Output REFRESH 4 4 USB STATISTICS The Diagnostics USB menu lists the connected USB devices For example USB Flash Memory For each line the number is the USB physical port number The associated label is given by the USB product itself If the USB product is supported more information can obtained by pressing Enter If a beep is sounded the product is not supported 46 AX3000 Using and Configuring the models 75D amp 85 PERSONAL NOTES AXEL 14 Avenue du Qu bec B t K2 EVOLIC BP 728 91962 Courtaboeuf cedex FRANCE Tel 33 1 69 28 27 27 Fax 33 1 69 28 82 04 Email info axel com
17. essions 30 3 3 2 Disconnecting Sessions 31 3 4 LOCKING THE SCREEN e ennemis 31 3 5 COPY PASTE FUNCTION nennen nennt nnns nnn 32 cereo ihn i r et e i aa ei eias 32 D Paste nsaan a bce caves A A a aas 33 3 6 TURNING OFF THE AX3000 33 3 7 AX3000 HOT KBYS iiien terrain er Pe b eee e en da 35 4 TOOLS AND STATISTICS eeeeeeeeeeeee enne nennen nnns nana nana nn nana inna nana 37 4 1 THE PING COMMAND nnnm nnns 38 4 2 CONNECTION MANAGEMENT nnns 38 4 2 1 Global Connection List 39 9 2 2 ICP Server and TCP Client Connection Information 40 4 3 INTERFACE INFORMATION nnns 42 4 3 1 Ethernet Interface eee e Ee Y ela EA FER a Y ERRARE 42 slim PTT 42 b DHCP DNS run iii cu ea cation orn e rica A 43 eei 44 4 3 2 Wireless Interface 45 a State sr rit ric oM rade pois ette Lester Stee tres os 45 b DHCPBP DNS ui iniecta tene dete ead a diae e eure eee eeu 46 uerus 46 4 4 USB STATISTICS tenir aed crede aee Pea eee ane 46 AXEL Introduction INTRODUCTION AX3000 Using and Configuring the models 75D amp 85 Introduction AXEL This manual is an addendum to the AX3000 User s Manual Only configuration and use of the models 75D and 85 are described We assume the reader is familiar with the wireless interface management and the AX3000 configuration The manual is or
18. f the password is forgotten the only way is selecting the Shutdown button After power cycling it the AX3000 administrator will be able to modify or remove the screen saver password Note For the highest level of security we recommend setting the terminals Set Up password See Chapter 3 2 5 3 5 COPY PASTE FUNCTION The terminal offers a Copy Paste function which operates either in the current session or between different sessions For example text can be copied from a 5250 session and pasted to a Windows session a Copy From a Windows Session RDP or ICA Use the standard Copy function For example Ctrl C From a VNC Session The vncconfig tool must be run The copy is simply done by selecting a text zone From a Text Session 5250 3270 ANSI VT Press lt Ctrl gt lt C gt with 5250 and 3270 emulations or lt Ctrl gt lt Alt gt lt C gt with 32 AX3000 Using and Configuring the models 75D amp 85 AXEL Using the AX3000 other emulations to enter the Copy mode Use the mouse to select the copy data Pressing lt Enter gt validates the selection and the text is copied into a local clipboard lt Esc gt cancels Copy Mode Note the Copy function is available only if the mouse is supported by the current session Note We are unable to use the standard of cont c as this is already used for another function within Unix Linux b Paste To Windows Session RDP or ICA
19. face minus the Link parameter AX3000 Using and Configuring the models 75D amp 85 19 Setting Up the Terminal AXEL The Wireless Parameters box is the following Wireless Parameters Interface State Profile lt Space gt CANCEL This box allows the wireless profile to be set up only one profile Note when the wireless interface is connected a DISCONNECT button is available a Selecting the SSID The first step is to enter the access point SSID This can be done manually or by a scan operation available only if the wireless interface is not currently connected The following shows a typical scan box press lt F2 gt f e Acces ints SSID BSSID Ch Signal Security AX_NETGEAR 1 90 1b 2f 71 f4 fa 13 307 WPAZ EAP CCMP REFRESH lt F2 gt 20 AX3000 Using and Configuring the models 75D amp 85 AXEL Setting Up the Terminal Note about hidden SSIDs they are listed as lt hidden gt If a hidden SSID is selected the actual SSID name must be manually entered If the selected SSID is listed multiple times a dialog box allows the connection to be forced or not to this SSID Forced BSSID b Configuring the SSID After the SSID selection press lt Space gt on Parameters to display the SSID settings box Security Advanced Identification Note if the SSID had been selected through a scan parameters are set in regard of the SSID security The dialog box may change depending of the P
20. ganized into the following chapters Chapter 1 Introduction to the AX3000 Introduction to the AX3000 s main features Chapter 2 Setting up the terminal Quick set up and interactive set up procedures Chapter 3 Using the AX3000 How to use the multi session feature and shutdown the AX3000 Chapter 4 Tools and Statistics Description of the embedded AX3000 tools ping statistics etc 2 AX3000 Using and Configuring the models 75D amp 85 AXEL Introduction to the AX3000 CHAPTER 1 INTRODUCTION TO THE AX3000 AX3000 Using and Configuring the models 75D amp 85 3 Introduction to the AX3000 AXEL This chapter introduces the main features of AXEL terminals 1 1 TERMINAL MODELS This manual covers configuration and use of all Axel terminals The following table lists the main differences between models M75 M85 M80F M75D M75C M70F M70W M75E M65C M75B Connection Ethernet TCP IP 10 100 10 100 10 100 10 100 10 100 10 100 10 100 10 100 BaseT BaseT BaseT BaseT BaseT BaseT BaseT BaseT Wireless 802 11 option option Serial RS232 yes USB yes yes yes yes Sessions Text Emulations yes yes yes yes yes d yes yes RDP ICA yes yes yes yes yes yes yes ges Virtual Desktop yes yes yes VNC Client yes yes yes yes yes em yes Nbr de colors 32bpp 32bpp 16bpp 16
21. isabled ACCEPT ADVANCED SETUP Press the ACCEPT button to use these settings After an automatic reboot the terminal is ready to be used The Advanced button enters the interactive setup where further configuring is possible For example adding different session types The BACK button allows these settings to be changed 2 2 INTERACTIVE SET UP The following can be used to enter the AX3000 interactive set up Using Ctrl Alt Esc from the terminal 16 AX3000 Using and Configuring the models 75D amp 85 AXEL Setting Up the Terminal Using Remote Control from AxRM Using Telnet from another terminal PC Note the set up can be password protected in which case the password must be entered to access the quick set up dialog box Note the following keystrokes are available in the set up Arrows moving selection within menus or dialog boxes Enter validating a value or a button Esc cancels current field same as selecting cancel button Space open a list of options Tab short cut to buttons at the bottom of the dialog box Ctrl C copy a character string or session settings lt Ctrl gt lt V gt paste information IMPORTANT the following deals only with the network configuration The network settings are available through the Configuration Network menu Configuration Diagnostics Download Network General Parameters Terminal Ethernet Interface IP
22. liary port where printer is attached none aux1 aux2 parallel USB1 Protocol LPD TSE Prt5250 or Prt3270 The next parameters are protocol dependent LPD Queue Name name given to the auxiliary port TSE Printer Name and Windows TSE Driver Prt5250 Printer Name and Driver printer type and model Prt3270 Printer Name Access Permission only for TSE and Citrix sessions where USB Mass Storage is supported AX3000 Using and Configuring the models 75D amp 85 13 Setting Up the Terminal AXEL 2 1 5 Citrix Published Application Desktop For session type Citrix ica and connection type Published App Desktop the following box is displayed Quick Set Up Citrix Published App Desktop Logon Authentication lt Space gt Browser Settings These parameters are Username default value for logon authentication optional Password press lt Space gt to enter the logon password Domain default value for logon authentication IP Address or DNS Name location of a farm s server Port TCP used by the exploration browser protocol 2 1 6 Citrix Published Application or Published Server For the session type Citrix ica with the connection type Published Application or Published Server the following box is displayed after the terminal reboots Quick Set Up Citrix Citrix Published Application TCP IP HTTP CANCEL 14 AX3000 Using and Configuring the models 75D amp
23. meter is set to no the AX3000 displays the first of the remaining active sessions If there are no remaining active sessions for example because the last active view has been disconnected the session manager is displayed 3 4 LOCKING THE SCREEN For security reasons it might be useful for the AX3000 operator to lock the screen rather than logging out Note the lock screen means the AX3000 screen is blanked but the current sessions are still connected and active There is no way to enter the AX3000 Set Up or to switch the session The only way to regain control is to enter the proper password The lock screen feature is associated with the screen saver function and must be enabled through the AX3000 Set Up Two methods are available to lock a screen AX3000 Using and Configuring the models 75D amp 85 31 Using the AX3000 AXEL Automatically when the terminal is idle keyboard or screen for a certain time the AX300 blacks out the monitor display The display is automatically restored as soon as a key is pressed A dialog box allowing the screen to be unlocked after password is entered is displayed Manually the lt Ctrl gt lt Alt gt lt S gt keystroke allows the screen to be locked immediately An unlock screen dialog box is displayed Two operations are possible Entering the password to unlock the screen Two passwords can be used the screen saver password and the set up password Resetting the AX3000 I
24. na 7 2 1 FIRST POWEREON dat aci dedi e doe dae to did a eta bri add aa 8 2T T FIST OCICS ds disci on fimi e tt pires 10 2 1 2 Interface Selection eene nnne nnn nnne 11 2 1 8 Network Connection 0 ccccceccecececececececececececececececcececececececececececeteeereess 12 214 D6VIGOS im tte rte it tue eq o de NR 13 2 1 5 Citrix Published Application Desktop sss 14 2 1 6 Citrix Published Application or Published Server 14 2 1 7 Senal CORNECUON esiti ti eee aai ed yan ea eee dee Peas 3 a das af 15 2 1 8 Set Up Summary dne na n Race Ert 16 2 2 INTERACTIVE SET UP ii 4 rir nr nta na sia di n nma sarai enn 16 2 2 1 General Parameters in enne enne nnne nnne nnn 18 2 2 2 Ethernet Interface nidi e e e Pl Ea rada 19 2 2 8 Wireless Interface 19 a Selecting the SSID enne 20 b Configuring the SSID 21 3 USING THE AX3000 121222a2a2a2nanaaaaaaaaaaaamanananananananaanananananananananananananananana 25 3 1 SWITCHING ON THE AX3000 sisi 26 3 1 1 Session Manager Classic Mode 27 3 1 2 Session Manager Desktop Mode 28 3 27 THE STATUS EINE ica i aet ida ii d t did dta roe a atr d ia ted rea 29 3 2 1 Gwitchinig Olf o e don die eet 29 3 2 2 Network Status eee eerte nennen tnn nnn 29 9 2 3 IDfoFmallon s iit ite e P e rie eR PE ERR REOR 30 3 3 USING MULTIPLE SESSIONS eene 30 3 3 1 Opening and Switching S
25. nment of One server An optional router All sessions set identically An optional printer Note After the Quick set up is run all other parameters within the terminal are reset to their factory default values The quick set up guides the user through a setup menu in an intuitive manner 8 AX3000 Using and Configuring the models 75D amp 85 AXEL Setting Up the Terminal The dialog box structure referred to as a Wizard is shown below FIRST SCREEN Graphical Environment Session Type Testing Graphical Settings optional INTERFACE Ethernet Wireless Selection 802 11 Settings SERIAL CONNECTION NETWORK CONNECTION Main port baudrate data IP Settings Default printer Server Settings REBOOT CITRIX SESSION CITRIX SESSION Other type Published App or Published App of sessions Published Server Desktop DEVICE Printer USB Drive SUMMARIZE AX3000 Using and Configuring the models 75D amp 85 9 Setting Up the Terminal AXEL Note the following keystrokes are available in the set up Arrows moving selection within menus or dialog boxes Enter validating a value or a button Esc cancels current field same as using cancel button Space lists of options Tab shortcut to buttons on the bottom of the dialog box 2 1 1 First Screen This first
26. nt session lt Ctrl gt lt Alt gt lt K gt lt Rest gt lt Alt gt lt K gt Changes the keyboard type PCGAS 400 lt Ctrl gt lt Alt gt lt Del gt lt Rest gt lt Alt gt lt Del gt Shuts down the AX3000 lt Ctrl gt lt Alt gt lt l gt Information about the RDP ICA or VNC current session lt Cirl gt lt Alt gt lt X gt lt Rest gt lt Alt gt lt X gt Opens the connection box lt Cirl gt lt Alt gt lt E gt lt Rest gt lt Alt gt lt X gt Displays Ethernet status box lt Cirl gt lt Alt gt lt W gt lt Rest gt lt Alt gt lt X gt Displays Wireless status box lt Ctrl gt lt Alt gt lt BackTab gt lt Rest gt lt Alt gt lt BackTab Set text mode set up gt lt Ctrl gt lt C gt or lt Rest gt lt C gt Selects and copies a screen lt Ctrl gt lt Alt gt lt C gt zone mouse is requested lt Ctrl gt lt V gt or lt Rest gt lt V gt Paste the text lt Ctrl gt lt Alt gt lt V gt Note keystrokes written in bold can be disabled AX3000 Using and Configuring the models 75D amp 85 35 AXEL Tools and Statistics CHAPTER 4 TOOLS AND STATISTICS AX3000 Using and Configuring the models 75D amp 85 37 Tools and Statistics AXEL This chapter describes the embedded AX3000 tools The AX3000 interactive set up provides the following administration features Ping command Connection management Interface information USB device list 4 1 THE PING COMMA
27. rotected Access value associated parameters depend of the access type The possible values of Protected Access are None encrypted WEP or non encrypted connection Personal PSK encrypted connection WPA WPA2 Enterprise EAP authenticated LEAP PEAP and encrypted WPA WPA2 connection 802 1X authenticated LEAP PEAP and encrypted WEP connection The following describes each protected access type AX3000 Using and Configuring the models 75D amp 85 21 Setting Up the Terminal AXEL Protected Access is None Security Data Encryption Authentication Mode WEP Key requested WEP Open yes Shared yes None Note a WEP key is a character string The key encoding is ASCII length 5 or 13 characters or hexadecimal length 10 or 26 characters For example the ASCII key value 12345 is 3132333435 in hexadecimal encoding Protected Access is Personal PSK Security Personal PSK AES CCMP 30 JE DE JE JE DE JE JE DE DE DE DE DE Data Encryption Passphrase requested AES CCMP yes TKIP yes Note the Personal PSK protected access is known as WPA or WPA2 The Axel terminal is able to dynamically select one of these two protocols If needed a specific protocol WPA or WPA2 can be forced It s done by the Wireless PSK EAP version in Configuration Advanced Tunings 22 AX3000 Using and Configuring the models 75D amp 8
28. screen allows the session type to be selected Terminal French TFT Flat Screen 1024x768 High Color 16 bit axel2C007B No Session None These parameters are Keyboard keyboard nationality Screen Type options are CRT Monitor or TFT Flat Screen Resolution available values depend on the terminal model Frequency only for CRT monitors 60Hz or 75Hz Colors 24bpp 16bpp or 8bpp according to the terminal model Terminal Name Remote control Allowed Session Type available values are TSE rdp Citrix ica Virtual Desktop VNC 5250 3270 and Text Emulation 10 AX3000 Using and Configuring the models 75D amp 85 AXEL Setting Up the Terminal Connection Type available only for the following Session Types Citrix ica Server local list Published Application Published Server or Published App Desktop Text Emulation telnet aux1 or ssh Virtual Desktop Citrix XEN Desktop or VMWARE VDM Emulation only available if Text Emulations is selected Number of sessions only available for Text Sessions For graphical sessions this number is 1 Note when exiting the dialog box the graphical settings resolution and frequency may be tested 2 1 2 Interface Selection The Interface Selection box is shown below Parameters Wireless Security Advanced Identification NEXT DISCONNECT AX3000 Using and Configuring the models 75D amp 85 11
29. splayed Possible actions Click a desktop icon to open a session The associated keystroke is also available Click in the status line See next chapter 28 AX3000 Using and Configuring the models 75D amp 85 AXEL Using the AX3000 The session icons are displayed below 3 3 eo a TSE Citrix Citrix Virtual Virtual Published App Published App Desktop Desktop Published Svr Desktop XEN VMWARE ve mM mM i Te VNC 5250 3270 Text Emulation 3 2 THE STATUS LINE When the status line is displayed possible actions are Click a session label switching session See next chapter Click one of the icons on the right side 3 2 1 Switching Off The 0 icon allows the terminal to be powered off For more information consult Chapter 3 6 3 2 2 Network Status The network status is shown by one of the following icons Wireless interface available El VVireless interface not connected ES Ethernet interface available B Ethernet cable not connected Click the network icon to get more information about the network status More information is available on Chapter 4 3 AX3000 Using and Configuring the models 75D amp 85 29 Using the AX3000 AXEL 3 2 3 Information The M icon allows terminal information to be displayed firmware revision MAC addresses Par example Hardware Firmware Comp Adresse MAC Ethernet Adresse MAC 802 11 Souris PS 2 3 3 USING MULTIPLE SE
30. to exit the login stage because there is no way to close the current telnet session To allow graceful shutdown an AX3000 shutdown function is available Press lt Cirl gt lt Alt gt lt Del gt A dialog box allows the next step to be selected SHUTDOWN button REBOOT button After selection all active connections screen and auxiliary port are closed For the Shutdown choice a few seconds later the user is informed that the AX3000 may be turned off 34 AX3000 Using and Configuring the models 75D amp 85 AXEL Using the AX3000 3 7 AX3000 HOT KEYS The AX3000 hot keys are listed in the following table PC Keyboard 5250 Keyboard Action lt Ctrl gt lt Alt gt lt Esc gt lt Rest gt lt Alt gt lt Esc gt Enters the AX3000 Set Up lt Alt gt lt Fx gt lt Alt gt lt Fx gt Switches session these hot key can be modified lt Alt gt lt gt lt Alt gt lt gt Switches to next session lt Alt gt lt gt lt Alt gt lt gt Switches to previous session lt Cirl gt lt Alt gt lt S gt lt Rest gt lt Alt gt lt S gt Locks the screen lt Ctrl gt lt Alt gt lt Pause gt lt Rest gt lt Alt gt lt Pause gt Sends a break code Note only for telnet protocol lt Ctrl gt lt Alt gt lt Prt Scr gt lt Rest gt lt Alt gt lt Prt Scr Performs a screen dump to the default auxiliary port Ctrl Alt D lt Rest gt lt Alt gt lt D gt Closes the curre