Home
gentleMACS™ Dissociator - QB3
Contents
1. Miltenyi Biotec gentleMACS Dissociator User manual Unless otherwise specifically indicated Miltenyi Biotec products and services are for research use only and not for therapeutic or diagnostic use MACS is a registered trademark gentleMACS is a trademark of Miltenyi Biotec GmbH Copyright 2010 Miltenyi Biotec GmbH All rights reserved No part of this user manual may be reproduced stored in a retrieval system transmitted published or distributed in any form or by any means electronically mechanically by photocopying microfilming recording or otherwise without the prior written consent of Miltenyi Biotec GmbH however notwithstanding the foregoing the owners of the gentleMACS Dissociator may make copies solely for purposes of training personnel in the use and servicing of the unit within their business or organization Maximal care has been taken by Miltenyi Biotec GmbH in the preparation of this user manual However Miltenyi Biotec GmbH shall not be liable for any technical or editorial errors or omissions contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this document The information in this document is provided as is without warranty of any kind and is subject to change without notice gentleMACS Dissociator User manual Miltenyi Biotec GmbH Friedrich Ebert Stra e 68 51429 Bergisch Gladbach Germany Phone 49 2204 8306 0 Fax
2. Technical specifications Size Weight Main power Motor Conditions of operation USB interface Length x Width x Height 347 mmx 215 mm x 195 mm 4 7 kg Power consumption max 320 VA Supply voltage 100 240 VAC 50 60 Hz Fuse 2x T4AH250V Rotational speed 200 4 000 rpm Rotation clockwise or counter clockwise Rotational acceleration 100 r s Torque minimum 150 mNm Overload restriction over the range of 200 4 000 rpm Working temperature 4 C to 35 C Humidity 15 80 relative non condensing Altitude maximum 2000 m Storage temperature 15 C to 70 C For service purposes only Pin 1 USB 5 V Pin 2 USB Pin 3 USB Pin 4 USB GND c UL us LISTED LABORATORY EQUIPMENT 527A The gentleMACS Dissociator is labeled as a protection class device and must be plugged into a grounded power outlet Supply voltage fluctuations up to 10 of the nominal voltage Transient overvoltages present on the mains supply category ll The instrument is suitable for rated pollution degree 2 Emission sound pressure level at workstation 70 dB A Design and specifications are subject to change without notice The gentleMACS Dissociator is designed to meet the requirements of the following standard FCC 47 CFR Ch 1 part 15 class B electromagnetic compatibility The gentleMACS Dissociator has been investigated by Underwriters Laboratories in accordance with the following standards UL61010 1 CAN CSA C22 2
3. e Verwendung des Ger ts sowie eine falsche oder unzureichende Pflege k nnen eine deutliche Verringerung der Lebensdauer und das Erl schen der Produktgew hrleistung nach sich ziehen Falsche Bedienung und Wartung sowie missbr uchliche Verwendung k nnen zu erh htem Verschlei f hren und Gefahren f r die Benutzer des Ger ts hervorrufen Im folgenden Abschnitt werden die Symbole beschrieben die in diesem Handbuch und auf dem gentleMACS Dissociator verwendet werden um Warnhinweise hervorzuheben Symbole Warnung Dreiecke deuten auf allgemeine Hinweise hin die vor Besch digungen des Ger ts oder schweren und potenziell t dlichen Verletzungen warnen Schlagen Sie im gentleMACS Dissociator Handbuch nach um weitere Informationen zu erhalten und verfahren Sie mit Vorsicht Warnung Dieses Symbol deutet auf das Risiko schwerer und potenziell t dlicher Verletzungen durch Hochspannung hin Schlagen Sie im gentleMACS Dissociator Handbuch nach um weitere Informationen zu erhalten und verfahren Sie mit Vorsicht Warnung Dieses Symbol deutet auf das Risiko schwerer und potenziell t dlicher Verletzungen oder der Besch digung des Ger ts durch chemische oder biologische Gefahrstoffe hin Schlagen Sie im gentleMACS Dissociator Handbuch nach um weitere Informationen zu erhalten und verfahren Sie mit Vorsicht 1 Wichtige Informationen 11 Hinweis Alle Sicherheitsanweisungen in diesem Handbuch m ssen streng eingehalten
4. precauci n 1 Informaci n importante 23 24 Nota Se deber n observar todas las instrucciones de seguridad del presente manual del usuario A Precaucion Este s mbolo indica el riesgo de causar da os al equipo si no se siguen con exactitud las instrucciones recogidas en el manual del usuario Por lo tanto se recomienda que quien opere el instrumento consulte los cap tulos pertinentes en la respectiva documentaci n Terminal conductor protector El s mbolo est situado en el interior del instrumento Advertencia s lo para el personal de servicio Encendido electricidad Apagado electricidad Advertencias y precauciones El presente cap tulo contiene informaci n para el manejo seguro del gentleMACS Dissociator A lo largo de todo el manual se recogen instrucciones detalladas sobre seguridad las cuales est n marcadas con los s mbolos Quien maneje el gentleMACS Dissociator es responsable de su correcto uso en cumplimiento de las instrucciones del presente manual y respetando la regulaci n local o nacional que sea aplicable Para un uso impecable y seguro del instrumento se presume que quienes lo manejan comprenden el manual y prestan atenci n a toda la informaci n sobre seguridad Mantenga este manual del usuario en lugar seguro accesible para quienes manejen el gentleMACS Dissociator Se deber n observar en todo momento las instrucciones de seguridad en el trabajo las normas del laboratorio y
5. re ou de d c s Consultez la notice d utilisation pour obtenir des instructions compl mentaires et soyez vigilant Avertissement IN Ce symbole attire l attention sur un risque de d c s de l op rateur sur machine ou de blessure s v re en raison de la tension lev e Consultez la notice d utilisation pour obtenir des instructions compl mentaires et soyez vigilant Avertissement Ce symbole attire l attention sur un risque de d c s de l op rateur sur machine ou de blessure s v re ou sur la d t rioration de l quipement en raison d un mat riau chimique ou biologique potentiellement dangereux Consultez la notice d utilisation pour obtenir des instructions compl mentaires et soyez vigilant 1 Informations importantes 15 16 Remarque Toutes les consignes de s curit mentionn es dans cette notice d utilisation doivent tre imp rativement respect es Attention Ce symbole attire l attention sur un risque de d t rioration de l quipement en cas de non respect des instructions mentionn es dans la notice d utilisation Il est par cons quent strictement conseill l op rateur sur machine de consulter les chapitres correspondants dans la documentation respective Protection de l utilisateur final Le symbole est plac l int rieur de l instrument Attention pour le personnel de maintenance seulement Marche Alimentation Arret Alimentation Avertissement et pr cautions prendre Ce chap
6. 49 2204 85197 macstec miltenyibiotec de Version 04 www miltenyibiotec com Original instructions Contents Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter 10 11 12 13 11 15 19 23 27 28 30 31 32 32 33 33 33 34 34 34 34 35 35 36 37 37 38 39 39 40 40 41 42 42 43 44 45 46 47 Important information Wichtige Informationen Informations importantes Informazioni importanti Informaci n importante Introduction gentleMACS Products and Spare Parts Storage and handling Installation Operating the gentleMACS Dissociator General information Description of the instrument Layout of the keyboard Panel buttons gentleMACS Program Card Function of the LED Display Power ON Function of the menus Select and run a program Copy a program Delete a program Emergency shutdown procedure Performance and limitations of use Maintenance Cleaning Cleaning procedure Disassembly for cleaning and reassembly Safety Internal quality control Disposal information Troubleshooting Technical specifications Limited warranty Technical service EC Declaration of conformity Important information Please read before use Please read all information contained in this chapter before use The use of an instrument for a task other than that for which it is intended as well as improper or insuffi
7. AS IS or WITH ALL FAULTS or consumables Nothing herein should be construed as constituting an additional warranty Miltenyi Biotec must be informed immediately if a claim is made under such warranty If a material or manufacturing defect occurs within the warranty period Miltenyi Biotec will take the appropriate steps to restore the full usability of the unit Limitation on damages Miltenyi Biotec shall not be liable for any incidental or conse quential damages for breach of any express or implied warranty or condition on this product Some states or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This warranty statement gives you specific legal rights and you may have other rights which vary from state to state or jurisdiction to jurisdiction 11 Limited warranty 45 12 Technical service For technical questions please contact your local distributor or our technical support team Miltenyi Biotec GmbH Friedrich Ebert Str 68 51429 Bergisch Gladbach Germany Phone 49 2204 8306 830 Fax 49 2204 8306 89 macstec miltenyibiotec de www miltenyibiotec com 46 12 Technical service EC Declaration of conformity 13 Name and address of the manufacturer Miltenyi Biotec GmbH Friedrich Ebert Str 68 51429 Bergisch Gladbach Germany The declaration of conformity refers to the machinery identified as follows Descr
8. No 61010 1 IEC 61010 2 051 For other safety considerations refer to the product label or visit www miltenyibiotec com 10 Technical specifications Limited warranty 11 Except as stated in a specific warranty statement which may accompany this product or unless otherwise agreed in writing by an authorized representative of Miltenyi Biotec Miltenyi Biotec s warranty if any with respect to this product is subject to the terms and conditions of sale of the company within the Miltenyi Biotec group which supplied the product Copies are available on request or at www miltenyibiotec com Terms and conditions of sale may vary by country and region Nothing herein should be construed as constituting an additional warranty Miltenyi Biotec s warranty for this product only covers product issues caused by defects in material or workmanship during ordinary use it does not cover product issues caused by any other reason including but not limited to product issues due to use in a manner other than specifically described in this manual for example inappropriate or improper use incorrect assembly or installation by an operator or a third party reasonable wear and tear negligent or incorrect handling servicing or maintenance non adherence to the operating instructions unauthorized modification of or to any part of this product or use of inappropriate accessories or work materials Miltenyi Biotec s warranty does not cover products sold
9. area and the top of the instrument must be accessible The gentleMACS Dissociator is a ready to use instrument 5 Installation 31 6 Operating the 32 gentleMACS Dissociator General information The gentleMACS Dissociator is used as a stand alone benchtop instrument A number of pre defined programs offer a variety of processes for tissue dissociation and tissue homogenization The specially designed gentleMACS Tubes are required for processing the samples The gentleMACS Dissociator must be used exclusively with these Tubes C Tubes are designed for the dissociation of tissues to obtain single cell suspensions M Tubes are designed for homogenization of tissues or cells to isolate subcellular material A single sample or two samples in parallel can be processed For details on the sample preparation see the respective gentleMACS Protocols which are available at www miltenyibiotec com protocols Below please find brief instructions for the use of the instrument For detailed information see the next sections Make sure that the gentleMACS Dissociator is switched ON The mains switch is located at the back panel of the instrument Pre defined programs are provided by the internal gentleMACS Dissociator memory Alternatively Insert the gentleMACS Program Card to run a program from the Program Card or to copy a program from the Program Card to the internal memory of the instrument Transfer the samples into the Tu
10. card will then automatically be selected to access programs If the gentleMACS Program Card is inserted only the programs from the Program Card are available The programs from the Program Card can be copied to the internal gentleMACS Dissociator memory To select programs from the internal memory remove the gentleMACS Program Card Function of the LED The LED indicates the instrument status for convenient monitoring Green System ready Green flashing Process running Red System error Red flashing Error during process Display Using the menu button the operator can switch between select copy and delete modes Select mode Program name gt lt Tube name gt Copy mode Copy Program name Delete mode Delete Program name gt Power ON vieta dun Display during initialization After initialization the green LED is on and the gentleMACS Dissociator is ready for operation Program name Tube name gt 6 Operating the gentleMACS Dissociator Function of the menus 6 Select and run a program To select a program from the internal gentleMACS Dissociator memory press the menu button until the select menu is displayed If the gentleMACS Program Card is inserted only the programs from this card are available To select programs from the gentleMACS Dissociator memory remove the gentleMACS Program Card To copy programs from the gentleMACS Program Card to the gentleMACS Dissocia
11. cleaning and or sterilization The remaining surface of the gentleMACS Dissociator should be cleaned with a cloth soaked with a detergent containing aqueous solution Carefully wipe all parts Repeat the procedure with another cloth soaked with distilled water If the homogenized substances are not water soluble it is recommended to wipe all parts with ethanol or an alternative organic solvent Contact Miltenyi Biotec technical support for further advice The removed parts should be washed in a laboratory dishwasher It is recommended to use a cleaning agent containing detergent and alkaline cleaning solution If necessary exchange the Sleeves and the Trough Reassemble the parts and make sure that the removed parts snap into position to ensure the correct positioning Disassembly for cleaning and reassembly Safety Shield Sleeves and Trough are removed by pulling precisely vertically with a slight force The Trough can be detached easily by slightly pressing the rippled sides Do not use any tools to detach the described parts Reassemble the parts in reverse order Correct assembly of all parts can be sensed by a slight snap as the part slips into its final position 8 Maintenance Safety 8 The gentleMACS Dissociator and the removable parts must be cleaned as described above The lifetime of the Sleeves might be limited due to the mechanical strain during the homogenization procedure Pe
12. droplets in Trough Tube is not closed properly Content of Tube is jammed between cap and Tube Tube seal is leaky Tube vibrates during run Sleeve is not installed correctly Inappropriate sample material Tube is not tightly held in position during run Tube does not fit properly into the snap fit of the Trough Tube is not closed properly gentleMACS Dissociator is without power Power cord is not connected Instrument is not switched ON Fuse is blown gentleMACS Dissociator does not read the Program Card Dust deposit on Program Card or Program Card is damaged User action Close Tube tightly beyond the first resistance The top area of cap and Tube must be perfectly clean for proper functionality of the seal Replace Tube Clean the instrument as described in chapter 8 Ensure correct installation of the Sleeve Make sure that the Sleeve snaps into position Refer to the respective datasheet for technical specifications of the gentleMACS Tubes Ensure correct installation of the Tube Close Tube tightly beyond the first resistance Check power cord Check mains switch at the rear panel of the instrument Check fuses at the rear panel of the instrument Replace fuses only with those of the same type and rating Check Program Card If any of the problems persist please contact our technical support team see chapter 12 9 Troubleshooting 43 10 Technical specifications 44
13. los est ndares sobre seguridad en el laboratorio y salud y de prevenci n de accidentes En caso de defectos del equipo que afecten a la seguridad se deber contactar con el servicio t cnico de Miltenyi Biotec Para garantizar el seguro manejo del gentleMACS Dissociator todas las tapas o partes que le hayan sido quitadas al gentleMACS Dissociator deben ser instaladas de nuevo antes de poner en funcionamiento el instrumento Evite la entrada de fluidos u otros objetos El manejo incorrecto del gentleMACS Dissociator conlleva riesgos mec nicos el ctricos qu micos y biol gicos 1 Informaci n importante Riesgos el ctricos 1 Tenga especial cuidado con los riesgos el ctricos Se deber n respetar en todo momento las normas de seguridad el ctrica S lo el personal cualificado podr realizar servicios el ctricos Est LETTS estrictamente prohibido manejar el instrumento cuando alguna parte est desmontada o estropeada El instrumento est equipado con un enchufe de tres alambres con toma tierra Esto es una medida de seguridad No introduzca el enchufe en una conexi n que no tenga toma tierra Sino es posible insertar el enchufe en la toma o si no est seguro que la conexi n tiene toma tierra contacte con su electricista local El equipo s lo debe hacerse funcionar en una fuente de alimentaci n de la potencia indicada en la etiqueta de potencias el ctricas del producto Si tiene dudas sobre qu fuente de alim
14. machine 1 Informations importantes Des risques peuvent survenir sous forme de dangers m caniques 1 electriques chimiques et biologiques en cas de manipulation incorrecte du gentleMACS Dissociator Dangers lectriques Soyez particuli rement vigilant en ce qui concerne les dangers lectriques Les pr cautions de s curit lectrique standard doivent tre appliqu es en permanence Seul le personnel qualifi est en droit de proc der la maintenance du syst me lectrique Il est strictement interdit de faire fonctionner la machine lorsque des pi ces sont d mont es ou endommag es L instrument est quip d une fiche lectrique m le C est une mesure de s rete N ins rez pas la prise male dans une prise femelle de courant non reli e la terre Si vous ne pouvez pas ins rer la fiche dans une prise de terre ou si vous n tes pas s r que ce soit une prise de terre contactez votre lectricien local L instrument peut tre seulement utilis avec la source de courant lectrique indiqu e sur l tiquette du produit Si vous avez des questions propos du type de voltage lectrique utiliser contactez votre fournisseur de services Miltenyi Biotec ou la compagnie d lectricit locale Assurez vous que l interrupteur principal ainsi que le cordon d alimentation sont facilement accessible et localis s autant que possible pr s de l utilisateur de l instrument S il est n cessaire de d connecter l alimen
15. on the inside of the instrument Warning for service personnel only On supply Off supply Warnings and precautions This chapter contains information for the safe operation of the gentleMACS Dissociator Detailed instructions regarding safety are provided throughout this manual marked with the symbols described above The operator is responsible for the correct use of the gentleMACS Dissociator following the instructions given in this manual and in full accordance with all local state and federal laws that may apply The impeccable and safe operation of the instrument presumes that any operator understands the user manual and pays attention to all safety information Keep this user manual in a safe place accessible for anyone using the gentleMACS Dissociator At all times local working area safety instructions laboratory policies and standards regarding laboratory safety and health and prevention of accidents must be adhered to In the case of safety relevant defects of the equipment Miltenyi Biotec technical service must be contacted To ensure safe operation of the gentleMACS Dissociator all covers or parts that have been removed from the gentleMACS Dissociator must be re installed prior to setting the instrument into operation Do not allow fluids or objects to enter the interior of the instrument Incorrect handling of the gentleMACS Dissociator bears risks in the form of mechanical electrical chemical and
16. 93 462 containing gentleMACS Programs A Only use accessories recommended by Miltenyi Biotec Failure to use recommended spare parts and disposables may compromise safe operation and may result in inaccurate results and reduced life time of the instrument Miltenyi Biotec does not honor any warranty or accept any responsibility for damages resulting from the use of inappropriate accessories 3 gentleMACS Products and Spare Parts 29 4 Storage and handling The gentleMACS Dissociator must be stored and operated under dry conditions non condensing humidity Storage temperature must be between 15 C and 70 C The instrument should be operated at a temperature between 4 C and 35 C 30 4 Storage and handling Installation 5 Please unpack the instrument carefully and check for completeness and for any damage that may have occurred during transportation If there is any damage contact your local Miltenyi Biotec representa tive or Miltenyi Biotec technical service Please keep the original packaging material The gentleMACS Dissociator is designed exclusively for indoor use Components included in delivery 1 gentleMACS Dissociator C Tubes 25 pieces M Tubes 25 pieces 1 Power cord 1gentleMACS Dissociator user manual Installation The gentleMACS Dissociator requires a flat surface with the dimensions 250 mm x400 mm and a power connection To operate the instrument the keyboard
17. and biological hazards The proper handling of the gentleMACS Tubes minimizes exposure to the samples However potential hazards to the operator still exist The operator must choose and wear personal safety eguipment in accordance with warnings and precautions for the used substances Defective or inadeguate safety eguipment might endanger the operator The gentleMACS Dissociator must be operated within a safety enclosure when hazardous or unknown materials are processed to protect persons and the laboratory environment from contamination All liguid and solid waste must be considered biohazardous and therefore must be handled taking universal laboratory precautions All clinical samples must be considered potentially infectious Toxic or corrosive chemicals poisonous acidic or radioactive substances may be present e It is strictly prohibited for anyone other than the operator to handle contaminated accessories or contaminated parts of the gentleMACS Dissociator After moving the gentleMACS Dissociator from a cold environ ment for example a cold room at 4 C to room temperature it is necessary to wait a minimum of 4 hours before setting the instrument into operation Condensing liquid droplets can severely damage the instrument 1 Important information Wichtige Informationen 1 Bitte vor Gebrauch lesen Bitte lesen Sie vor Ingebrauchnahme alle Hinweise in diesem Kapitel Eine nicht bestimmungsgem
18. bes Make sure that the Tubes are securely closed Make sure to properly install the Tubes vertically and upside down onto the Sleeves Proper installation will ensure that the Tubes are held in position against rotational and axial forces Allfunctions of the gentleMACS Dissociator must be controlled via the display see the following sections for details Select one of the programs offered by the instrument memory or by the gentleMACS Program Card Start the process by pressing the start button The display indicates the program name and the remaining time seconds for the current program to finish The end of the process is displayed for 5 seconds Subsequently the display indicates the program that has just been used By pressing the start button this program can be applied immediately to process the next sample Remove the Tubes containing the sample by pulling it vertically from the Sleeve 6 Operating the gentleMACS Dissociator Description of the instrument 6 Layout of the keyboard start stop Panel buttons Selection of one of the three modes that allow the user to select a program for sample processing or copy or delete programs o Selection of a program o Confirmation of a selection or function Run or stop a process 6 Operating the gentleMACS Dissociator 33 34 gentleMACS Program Card Insert the gentleMACS Program Card in the direction indicated by the arrow The
19. biological hazards 1 Important information Electrical hazards Please be particularly aware of electrical hazards Standard electrical safety precautions must be applied at all times Only qualified personnel are permitted to perform electrical servicing It is strictly forbidden to operate the instrument with disassembled or damaged parts The instrument is equipped with a three wire electrical grounding type plug This is a safety feature Do not insert the plug into a non grounded power outlet If you cannot insert the plug into the outlet or if you are not sure whether the outlet is grounded contact your local electrician The instrument should only be operated from a power source indicated on the product s electrical ratings label If you have questions about the type of power source to use contact your authorized Miltenyi Biotec service provider or local power company Make sure that the mains switch as well as the connector for the power cable are easily accessible and located as close to the operator of the instrument as possible If it is necessary to disconnect the power supply unplug the cable from the power outlet Servicing Unless otherwise mentioned in the Miltenyi Biotec documentation do not service the equipment yourself Service needed on compo nents inside the instrument must be carried out only by personnel trained and authorized by Miltenyi Biotec 1 Important information 1 10 gt Pp Chemical
20. chiature elettriche Gli interventi sull impianto elettrico devono essere eseguiti esclusivamente da personale qualificato E severamente vietato utilizzare lo strumento con parti non installate o danneggiate Lo strumento fornito di una presa a tre uscite con messa a terra Questa una caratteristica di sicurezza Non provare ad inserire la presa in un uscita di corrente non dotata di messa a terra Qualora non si riuscisse ad inserire la presa nell uscita corrispondente o se non si sicuri che la presa non dotata di messa a terra contattare un elettricista Lo strumento dovrebbe essere messo in funzione solo attraverso la fonte d alimentazione indicata sull etichetta che indica il livello d intensit elettrica del prodotto Se si hanno domande circa la tipologia della fonte d alimentazione da utilizzare si contatti il servizio d assistenza Miltenyi Biotec autorizzato o la compagnia di fornitura elettrica locale Assicurarsi che l interruttore ed il connettore per il cavo di alimentazione siano accessibili e posti il pi vicino possible all operatore che utilizza lo strumento Se fosse necessario staccare la corrente rimuovere il cavo dalla presa d uscita Assistenza Se non diversamente specificato nella documentazione fornita da Miltenyi Biotec non effettuare assistenza sull apparecchiatura da soli L assistenza necessaria per i componenti interni dello strumento deve essere eseguita solamente da personale addestrato e auto
21. cient maintenance can greatly reduce the life time of the instrument and will invalidate the instrument s warranty Incorrect handling and care as well as misuse can lead to premature wear or can cause hazards to users The following chart is an illustrated glossary depicting the symbols that are used in this user manual and on the gentleMACS Dissociator Symbols Warning Triangles indicate general warnings Warnings include the risk of damage to the equipment severe personal injury or loss of life Consult the user manual for further instructions and proceed with caution Warning This symbol indicates the risk of loss of life or severe injury to the instrument operator due to high voltage Consult the user manual for further instructions and proceed with caution Warning This symbol indicates the risk of loss of life severe injury to the instrument operator or equipment damage due to potentially dangerous chemical or biological material Consult the user manual for further instructions and proceed with caution Caution This symbol indicates the risk of equipment damage if instructions in the user manual are not followed precisely It is therefore strongly recommended that the instrument operator consult the correspond ing chapters in the respective documentation 1 Important information Note All safety instructions in this user manual must be strictly adhered to Protective conductor terminal Symbol is attached
22. densa possono danneggiare gravemente lo strumento 1 Informazioni importanti Informaci n importante 1 iPor favor leer antes de usar Por favor leer toda la informaci n contenida en este capitulo antes de su uso El uso de un instrumento para una tarea distinta de aquella para la que se ha creado as como un mantenimiento impropio o insuficiente puede reducir la vida media del aparato grandemente e invalidar la garantia del equipo Su manejo o cuidado incorrecto as como su uso inadecuado puede llevar a su desgaste prematuro o a riesgos para los usuarios El siguiente gr fico es un glosario ilustrado en el que se representan los s mbolos empleados en este manual del usuario y en el gentleMACS Dissociator S mbolos Advertencia Los tri ngulos indican una advertencia de tipo general que incluye da os al equipo lesiones corporales graves o muerte Consulte el manual del usuario para obtener m s informaci n y act e con precauci n Advertencia Este s mbolo indica peligro de muerte o graves lesiones causadas por el alto voltaje para quien maneje el instrumento Consulte el manual del usuario para obtener m s informaci n y act e con precauci n Advertencia Este s mbolo indica peligro de muerte graves lesiones para quien maneje el instrumento o da os al equipo debido a materiales qu micos o biol gicos potencial mente peligrosos Consulte el manual del usuario para obtener m s informaci n y act e con
23. designed for safe and sterile sample handling A number of gentleMACS Programs have been specifically devel oped to offer standardized procedures for the gentle dissociation or homogenization of various tissues A single sample or two samples in parallel can be processed A comprehensive gentleMACS Program overview and specific protocols for numerous applications are available for download at www gentlemacs com 2 Introduction 27 3 gentleMACS Products and Spare Parts gentleMACS Products Product Description Order no gentleMACS gentleMACS Dissociator 130 093 235 Starting Kit C Tubes 25 pieces M Tubes 25 pieces 1 Power cord 1 gentleMACS Dissociator user manual C Tubes For the dissociation of tissues to obtain 130 093 237 single cell suspensions 25 tubes single packed M Tubes For the homogenization of tissues or 130 093 236 cells to isolate subcellular material 25 tubes single packed 50 tubes per bag 130 093 458 M Tubes 50 tubes per bag 130 094 392 with Strainer strainer 600 um mesh For more information visit www miltenyibiotec com 28 3 gentleMACS Products and Spare Parts gentleMACS Spare Parts 3 Product Description Order no gentleMACS Sleeves 2 adapters for 130 093 464 attachment of l gentleMACS Tubes gentleMACS Trough Container for 130 093 465 liquid waste gentleMACS Safety Shield Safety shield for protection 130 093 466 gentleMACS Program Card Memory card 130 0
24. e i cui tappi devono essere ben chiusi Non utilizzare lo strumento coni soli tappi dei gentleMACS Tube Informaci n importante Por favor tenga presente la siguente precauci n El instrumento s lo debe ser usado con Tubos gentleMACS Tubes adecuadamente instalados cuyas tapas est n firmemente cerradas No utilice el instrumento s lo con las tapas de los gentleMACS Tubes Miltenyi Biotec provides products and services worldwide Visit www miltenyibiotec com local to find your nearest Miltenyi Biotec contact MACS is a registered trademark and gentleMACS is a trademark of Miltenyi Biotec GmbH Unless otherwise specifically indicated Miltenyi Biotec products and services are for research use only and not for therapeutic or diagnostic use Copyright 2010 Miltenyi Biotec GmbH All rights reserved
25. e y por ello deben ser manejados siguiendo las normas de seguridad en el laboratorio Todas las muestras cl nicas deben ser consideradas potencialmente infecciosas Podr n estar presentes sustancias qu micas t xicas o corrosivas o sustancias venenosas cidas o radiactivas Est terminantemente prohibido que alguien distinto del responsable maneje accesorios contaminados o partes contaminadas del gentleMACS Dissociator Despu s de pasar el gentleMACS Dissociator de una temperatura baja por ejemplo de una c mara refrigeradora a 4 C a temperatura ambiente habr que esperar 4 horas como m nimo antes de poner en funcionamiento el instrumento Las gotas de l quido condensado pueden da ar severamente el instrumento 1 Informaci n importante Introduction 2 The gentleMACS Dissociator is a benchtop instrument for the automated dissociation of tissues to obtain single cell suspensions Single cell suspensions are a crucial prerequisite to achieve reliable results in cell separation cell analysis and cell culture Moreover the gentleMACS Dissociator can be used for the homogenization of cells and tissues to extract biomolecules for molecular biology or protein biochemistry applications Two types of gentleMACS Tubes have been specially designed C Tubes for the gentle preparation of single cell suspensions from tissues and M Tubes for the homogenization of tissues and cells Both types of tubes are
26. entaci n debe utilizar p ngase en contacto con su representante autorizado de Miltenyi Biotec o la compania de suministro el ctrico local Aseg rese de que el interruptor principal as como el conector para el cable de transmisi n est n f cilmente accesibles y localizados lo m s cerca posible del operario del equipo Si es necesario desconectar el suministro de energ a desenchufe el cable de la toma de electricidad Mantenimiento A menos que se mencione lo contrario en la documentaci n de Miltenyi Biotec no haga usted mantenimiento del equipo El mantenimiento de los componentes del interior del equipo debe llevarlo a cabo nicamente personal preparado y autorizado por Miltenyi Biotec 1 Informaci n importante 25 26 gt Riesgos qu micos o biol gicos El correcto manejo de los gentleMACS Tubes minimiza la exposici n a las muestras Sin embargo siguen existiendo riesgos para quien los maneje Dicha persona deber llevar puesto el equipo de seguridad de acuerdo con las advertencias y precauciones para las sustancias utilizadas Un equipo de seguridad defectuoso o inadecuado puede poner en peligro su seguridad Cuando se procesen materiales peligrosos o desconocidos el gentleMACS Dissociator se manejar en un recinto de seguridad a fin de proteger de la contaminaci n a las personas y al laboratorio Todos los residuos l quidos o s lidos que se generen deben ser considerados peligrosos biol gicament
27. er service Netherlands Phone 0800 4020120 Fax 0800 4020100 Customer service Belgium Phone 0800 94016 Fax 0800 99626 Customer service Luxembourg Phone 800 24971 Fax 800 24984 China Miltenyi Biotec Trading Shanghai Co Ltd Shanghai Office Fareast International Plaza A Rm 2301 No 319 Xianxia Rd Shanghai 200051 P R China Phone 86 21 62351005 Fax 86 21 62350953 macs miltenyibiotec com cn France Miltenyi Biotec SAS 10 rue Mercoeur 75011 Paris France Phone 33 1 56 98 16 16 Fax 33 156 98 16 17 macs miltenyibiotec fr Italy Miltenyi Biotec S r l Via Persicetana 2 D 40012 Calderara di Reno BO Italy Phone 39 051 6 460 411 Fax 39 051 6 460 499 macs miltenyibiotec it Japan Miltenyi Biotec K K Nittsu Eitai Building 5F 16 10 Fuyuki Koto ku Tokyo 135 0041 Japan Phone 81 3 5646 8910 Fax 81 3 5646 8911 macs miltenyibiotec jp Singapore Miltenyi Biotec Asia Pacific Pte Ltd 100 Beach Road 28 06 to 28 08 Shaw Tower Singapore 189702 Phone 65 6238 8183 Fax 65 6238 0302 macs miltenyibiotec com sg Spain Miltenyi Biotec S L C Luis Bu uel 2 Ciudad de la Imagen 28223 Pozuelo de Alarc n Madrid Spain Phone 34 91 512 12 90 Fax 34 91 512 12 91 macs miltenyibiotec es United Kingdom Miltenyi Biotec Ltd Almac House Church Lane Bisley Surrey GU24 9DR UK Phone 44 1483 799 800 Fax 44 1483 799 811 macs miltenyibiotec co uk Miltenyi Biotec provides products a
28. erating the gentleMACS Dissociator 37 Performance and limitations of use 38 A maximum of 99 programs can be stored on the internal gentleMACS Dissociator memory Editing programs on the gentleMACS Dissociator is not possible If an error occurs the gentleMACS Dissociator displays a message that needs to be confirmed by the operator Press the stop button in order to continue operation Both motors run at the same time theoretically at identical speed and acceleration However the friction and resistance of the sample will decrease the effective speed The gentleMACS Dissociator will display an error message if a pre set tolerance has been exceeded during the process If one of the motors is blocked due to high resistance of the sample in the tube the instrument will try four times to get started again The message Error Motor 1 2 blocked appears and the red LED flashes The operator must confirm the incident by pressing the stop button If the blockage can be resolved the gentleMACS Dissociator continues the procedure from where it was interrupted The message Warning x Retries appears for 5 seconds during the incident and disappears automatically If the blockage cannot be resolved the power of the motor is turned OFF 7 Performance and limitations of use Maintenance 8 Cleaning In case of spillage or contamination clean the instrument appropri ately For decontamination use 7096 ethanol or a 196 hypochlori
29. erbindung mit dem technischen Kundendienst von Miltenyi Biotec aufgenommen werden Um einen sicheren Betrieb des Ger ts zu gew hrleisten m ssen alle entfernten Abdeckungen oder Teile wieder eingebaut werden bevor das Ger t in Betrieb genommen wird Fl ssigkeiten oder Gegenst nde d rfen nicht in das Innere des Ger ts gelangen 1 Wichtige Informationen Eine unsachgem e Handhabung des Ger ts kann mechanische 1 elektrische chemische und biologische Gef hrdungen verursachen Gefahr eines Stromschlags E Bei elektrischen Ger ten besteht die Gefahr eines Stromschlags Um das Risiko eines Stromschlags zu reduzieren m ssen standardm ige Vorsichtsma nahmen getroffen werden Nur daf r qualifizierte Personen d rfen die Elektrik des Ger ts warten Es ist verboten ein Ger t in Betrieb zu nehmen das unvollst ndig zusammengebaut ist oder besch digte Teile enth lt Das Instrument ist mit einem Netzstecker versehen der f r die elektrische Erdung bestimmt ist Dies ist eine Sicherheitsvorkehrung Stecken Sie den Stecker nicht in eine Steckdose die nicht geerdet ist Falls Sie unsicher sind ob die Steckdose geerdet ist wenden Sie sich an einen Elektriker Das Instrument sollte nur aus einer Stromquelle versorgt werden die mit der Klassifizierung bereinstimmt die auf dem Typenschild angegeben ist Falls Sie Fragen zur Stromversorgung haben wenden Sie sich an Ihren Miltenyi Biotec Kundendienst oder an Ihre Stromverso
30. iption laboratory equipment for mixing and stirring Function dissociaton of tissues to obtain single cell suspensions or homogenization of tissues Model gentleMACS Dissociator We hereby declare that the machinery complies with all essential requirements of the following directives 2004 108 EC electromagnetic compatibility 2006 42 EC machinery and is in conformity with the following harmonized standards C EN 61010 1 2001 EN 61010 2 051 2003 EN 61326 1 2006 Person authorized to compile the relevant technical documentation Stefan Miltenyi Miltenyi Biotec GmbH Friedrich Ebert Str 68 51429 Bergisch Gladbach Germany Bergisch Gladbach December 29 2009 Stefan Miltenyi Managing Director 13 EC Declaration of conformity 47 Miltenyi Biotec Germany Austria Switzerland Miltenyi Biotec GmbH Friedrich Ebert Stra e 68 51429 Bergisch Gladbach Germany Phone 49 2204 8306 0 Fax 449 2204 85197 macs miltenyibiotec de USA Canada Miltenyi Biotec Inc 2303 Lindbergh Street Auburn CA 95602 USA Phone 800 FOR MACS Phone 1 530 888 8871 Fax 1 530 888 8925 macs miltenyibiotec com www miltenyibiotec com Australia Miltenyi Biotec Australia Pty Ltd Unit 16A 2 Eden Park Drive North Ryde NSW 2113 Australia Phone 61 2 8877 7400 Fax 461 2 9889 5044 macs miltenyibiotec com au Benelux Miltenyi Biotec B V Postbus 85183 3508 AD Utrecht The Netherlands macs miltenyibiotec nl Custom
31. itre contient des informations relatives au fonctionnement sans danger du gentleMACS Dissociator Vous trouverez dans ce manuel des consignes de s curit d taill es pr c d es des symboles L op rateur est responsable de l utilisation correcte du gentleMACS Dissociator conform ment aux instructions donn es dans ce manuel et conform ment la l gislation locale r gionale et f d rale en vigueur Afin de garantir le fonctionnement correct et sans danger de la machine tout op rateur doit tre en mesure de comprendre le manuel de fonctionnement et tenir compte de toutes les informations relatives la s curit Conservez cette notice d utilisation dans un endroit s r et accessible toute personne utilisant le gentleMACS Dissociator Les consignes de s curit s appliquant la zone de travail locale les r glementations du travail en laboratoire et les normes de s curit des laboratoires les normes de sant et les normes de pr vention des accidents doivent tre respect es en permanence Si vous constatez des d fauts de s curit sur l quipement contactez imp rativement le service technique de Miltenyi Biotec Afin de garantir le fonctionnement sans danger du gentleMACS Dissociator toutes les protections ou pi ces ayant t retir es du gentleMACS Dissociator doivent tre remises en place avant de mettre la machine en fonctionnement Emp chez tout fluide ou objet de parvenir l int rieur de la
32. nd services worldwide Visit www miltenyibiotec com local to find your nearest Miltenyi Biotec contact Unless otherwise specifically indicated Miltenyi Biotec products and services are for research use only and not for therapeutic or diagnostic use MACS is a registered trademark and gentleMACS is a trademark of Miltenyi Biotec GmbH Copyright 2010 Miltenyi Biotec GmbH All rights reserved 140 002 197 04 Miltenyi Biotec gentleMACS Dissociator User manual Addendum A Important information Please adhere to the following precaution The instrument must be used only with properly installed gentleMACS Tubes whose lids are tightly closed Do not operate the instrument with gentleMACS Tube lids only Wichtige Information Bitte beachten Sie folgende Sicherheitsma nahme Das Ger t darf nur mit korrekt installierten gentleMACS Tubes deren Deckel fest verschlossen sind betrieben werden Nehmen Sie das Ger t nicht mit Deckeln ohne R hrchen in Betrieb Information importante Suivez s il vous plait les pr cautions suivantes L instrument doit tre utilis seulement avec les gentleMACS Tubes correctement install s et dont le bouchon est bien ferm N utilisez pas l instrument avec seulement les bouchons des gentleMACS Tubes A Informazioni importanti Per favore attenersi alle seguenti precauzioni Lo strumento deve essere utilizzato unicamente con i gentleMACS Tube correttamente installati
33. re responsabile dell uso corretto del gentleMACS Dissociator conformemente alle istruzioni riportate nel presente manuale e in osservanza di tutte le disposizioni locali e nazionali vigenti Per un utilizzo corretto e sicuro dello strumento necessario che l operatore abbia compreso le istruzioni riportate nel manuale d impiego e che segua tutte le informazioni di sicurezza Conservare il presente manuale d impiego in luogo sicuro accessibile a tutti gli addetti che utilizzano il gentleMACS Dissociator E necessario seguire sempre le istruzioni di sicurezza locali per gli ambienti di lavoro le politiche di laboratorio e le direttive relative alla sicurezza e alla salute nei laboratori e la prevenzione degli incidenti In caso di guasti alle attrezzature che possono comprometterne la sicurezza necessario contattare il servizio di assistenza tecnica Miltenyi Biotec Per garantire il funzionamento sicuro del gentleMACS Dissociator tutti i coperchi o le parti rimosse dallo strumento devono essere reinstallate prima di avviare il gentleMACS Dissociator Evitare che liquidi o oggetti penetrino all interno dello strumento 1 Informazioni importanti IN L impiego scorretto del gentleMACS Dissociator comporta rischi di 1 tipo meccanico elettrico chimico e biologico Rischi elettrici E IN Si raccomanda di prestare particolare attenzione ai rischi elettrici Vanno sempre adottate le precauzioni di sicurezza standard per le apparec
34. rgungsgesellschaft Stellen Sie sicher dass der Hauptschalter und der Anschluss f r das Stromkabel leicht zug nglich sind und sich in Reichweite der Person befinden die das Instrument bedient Falls es notwendig sein sollte die Stromversorgung zu unterbrechen ziehen Sie den Stecker aus der Steckdose Wartung Falls nicht anders in den Dokumenten von Miltenyi Biotec vermerkt warten Sie das Instrument nicht selbst Wartungsarbeiten an Teilen im Innern des Instruments d rfen nur von Personen durchgef hrt werden die von Miltenyi Biotec geschult und daf r berechtigt wurden 1 Wichtige Informationen 13 14 gt gt Chemische und biologische Gef hrdung Eine sachgem e Handhabung der gentleMACS Tubes minimiert das Risiko f r den Benutzer mit der Probe in Kontakt zu kommen Die M glichkeit einer Gef hrdung bleibt jedoch bestehen Der Benutzer des Ger ts muss eine dem Gefahrenpotential angemessene Sicherheitsausr stung tragen Das Tragen defekter oder unzureichender Sicherheitsausr stung kann eine Gef hrdung des Benutzers darstellen Der gentleMACS Dissociator muss in einem umschlossenen Sicherheitsbereich betrieben werden falls Gefahrstoffe oder unbekannte Stoffe verarbeitet werden Alle fl ssigen und festen Abf lle m ssen als biologische Gefahrstoffe angesehen werden Die Handhabung der Abf lle muss deshalb unter Beachtung allgemeiner Vorsichtsma nahmen erfolgen Alle Proben klinischer Herkunft m
35. riodically check the parts for wear Attention Decontamination is within the responsibility of the operator of the instrument Contaminated instruments or removable parts must not be given to any person After detachment and reassembly of any removable part it is necessary to check that the part still functions properly Applied materials Housing middle part PA 66 6 with 30 glass fibers Housing front part PA 66 6 with 30 glass fibers Housing rear part PA 66 6 with 30 glass fibers Keyboard Polyester film gentleMACS Safety Shield PP gentleMACS Trough PA 66 6 with 30 glass fibers gentleMACS Sleeve PA 66 6 with 30 glass fibers NO uBWN u A W IN l 8 Maintenance 41 42 AN Internal quality control During the lifetime of the instrument no calibration is necessary To check the quality of the instrument the gentleMACS Dissociator must be sent to Miltenyi Biotec Disposal information The gentleMACS Dissociator shall be disposed of according to the biosafety level of its use Potentially contaminated parts must be sterilized before being disposed of according to local laboratory regulations Attention Decontamination is within the responsibility of the operator of the instrument Contaminated instruments or contaminated parts of the instrument must not be sent or given to any person 8 Maintenance Troubleshooting Error Source of error Liquid
36. rizzato da Miltenyi Biotec 1 Informazioni importanti 21 22 gt DB Rischi chimici e biologici La corretta manipolazione delle gentleMACS Tubes riduce al minimo l esposizione ai campioni Esistono tuttavia rischi potenziali per l operatore L operatore tenuto a scegliere e indossare dispositivi di sicurezza personale appropriati e conformi alle avvertenze e precauzioni per le sostanze impiegate L uso di dispositivi di protezione personale inadeguati o difettosi puo rappresentare un pericolo per l operatore ll gentleMACS Dissociator deve essere utilizzato in un ambiente sicuro quando si manipolano sostanze pericolose o sconosciute in modo da proteggere gli addetti e l ambiente di laboratorio da possibili contaminazioni e Tutti i reflui liquidi e solidi devono essere considerati come rifiuti biologicamente pericolosi e vanno pertanto manipolati adottando le precauzioni di laboratorio standard Tutti i campioni clinici vanno considerati come potenzialmente infetti Possono essere presenti agenti chimici tossici o corrosivi sostanze acide velenose o radioattive severamente proibito ai non addetti di manipolare accessori o componenti contaminati del gentleMACS Dissociator In caso di trasferimento del gentleMACS Dissociator da un ambiente freddo ad esempio un locale a 4 C ad un locale con temperatura ambiente necessario attendere almeno 4 ore prima di utilizzare lo strumento Le gocce di con
37. s ou radioactives est possible Il est strictement interdit toute personne autre que l op rateur de manipuler des accessoires contamin s ou des pi ces contamin es du gentleMACS Dissociator Apr s avoir retir le gentleMACS Dissociator d un environnement froid par exemple apr s l avoir fait passer d une pi ce o la temp rature tait de 4 C la temp rature ambiante il est n cessaire d attendre au moins 4 heures avant de mettre la machine en fonctionnement Les gouttelettes du liquide de condensation peuvent causer des dommages s v res la machine 1 Informations importantes Informazioni importanti 1 Si prega di leggere prima dell uso Si prega di leggere tutte le informazioni contenute in questo capitolo prima dell uso Limpiego dello strumento per applicazioni diverse da quelle per cui stato ideato cosi come l uso improprio dello stesso senza adeguata manutenzione pu ridurre la durata dello strumento eannullarne la garanzia L errato impiego e utilizzo cosi come l uso improprio possono causare un logorio prematuro dello strumento o provocare situazioni di pericolo per gli utilizzatori Di seguito viene riportato un glossario illustrato dei simboli utilizzati nel presente manuale d impiego e sul gentleMACS Dissociator Symboli Avvertenza I triangoli indicano avvertenze di carattere generale Le avvertenze includono il rischio di danni alle attrezzature gravi lesioni personali o morte Con
38. ssen als m glicherweise infekti s angesehen werden Gef hrdung durch toxische oder tzende Chemikalien giftige s urehaltige oder radioaktive Stoffe ist m glich Kontaminierte Ger teteile oder Zubeh rteile d rfen ausschlie lich vom Benutzer gehandhabt werden Wenn der gentleMACS Dissociator aus einem K lteraum 4 C in einen Raum mit Raumtemperatur berf hrt wird muss ein Zeitraum von mindestens 4 Stunden abgewartet werden bevor das Ger t in Betrieb genommen wird Durch Kondensation entstandene Wassertr pfchen k nnen das Ger t besch digen 1 Wichtige Informationen Informations importantes 1 Avant toute utilisation veuillez lire attentivement les indications suivantes L utilisation d un instrument une fin autre que celle laquelle il est destin ainsi qu une mauvaise maintenance peut s rieusement r duire la dur e de vie et annuler la garantie de l instrument Une mauvaise manipulation ou utilisation de l instrument peut entrainer une usure pr coce de ce dernier et peut repr senter un danger pour les utilisateurs Le tableau suivant est un glossaire illustr expliquant la signification des symboles utilis s dans cette notice d utilisation et appos s sur le gentleMACS Dissociator Symboles Avertissement A Les triangles attirent l attention sur des dangers d ordre g n ral Ces avertissements incluent le risque de d t rioration de l quipement de blessure corporelle s v
39. sultare il manuale d impiego per ulteriori istruzioni e procedere con cautela Avvertenza Questo simbolo indica il rischio di morte o gravi lesioni personali a danno dell operatore a causa della presenza di alta tensione Consultare il manuale d impiego per ulteriori istruzioni e procedere con cautela Avvertenza Questo simbolo indica il rischio di morte o gravi lesioni personali a danno dell operatore o danni alle attrezzature a causa di materiale chimico e biologico potenzialmente pericoloso Consultare il manuale d impiego per ulteriori istruzioni e procedere con cautela 1 Informazioni importanti 19 20 Nota Seguire scrupolosamente tutte le istruzioni di sicurezza riportate nel presente manuale Attentione Questo simbolo indica il rischio di danni alle attrezzature qualora le istruzioni del manuale d impiego non vengano seguite scrupolosamente Si raccomanda pertanto la consultazione da parte dell operatore dei relativi capitoli nella documentazione fornita Terminale protettivo del conduttore Questo simbolo situato all interno dello strumento Questo segnale rivolto esclusivamente al personale che effettua l assistenza Acceso corrente Spento corrente Avvertenze e precauzioni Questo capitolo contiene informazioni relative al funzionamento sicuro del gentleMACS Dissociator Nel manuale vengono riportate istruzioni dettagliate relative agli aspetti di sicurezza evidenziate dai simboli L operato
40. tation d branchez la prise Services Sauf indication contraire mentionn e dans la documentation Miltenyi Biotec ne r parez pas l instrument vous m me Les r parations n cessaires sur les composants internes de l instrument doivent tre r alis es seulement par un personnel form et autoris par Miltenyi Biotec 1 Informations importantes 17 18 gt gt D Dangers chimiques et biologiques La manipulation correcte des gentleMACS Tubes r duit l exposition aux chantillons Toutefois l op rateur reste expos des risques potentiels L op rateur doit choisir et porter un quipement de s curit personnel conform ment aux avertissements mentionn s et aux pr cautions prendre selon les substances utilis es Un quipement de s curit d fectueux ou inappropri peut repr senter un danger pour l op rateur LegentleMACS Dissociator doit tre utilis dans une enceinte de protection en cas de manipulation de mat riaux dangereux ou inconnus afin de prot ger les personnes et l environnement du laboratoire de toute contamination ventuelle Tous les d chets liquides et solides doivent tre consid r s comme nocifs pour l organisme et doivent par cons quent tre manipul s avec les pr cautions de laboratoire universelles Tousles chantillons cliniques doivent tre consid r s comme potentiellement infectieux La pr sence de substances chimiques toxiques ou corrosives nocives acide
41. te solution A Do not allow fluids or objects to enter the interior of the instrument Make sure to clean the instrument exclusively with cleaning agents recommended by Miltenyi Biotec Do not use acetone or any BE aggressive agents Do not leave Tubes attached to the instrument while it is not in use When processing infectious radioactive poisonous or any other hazardous liquids always abide by the necessary safety precau tions Before using organic solvents or aggressive chemicals in the dissociation or homogenization process the compatibility with the gentleMACS Dissociator parts and Tubes must be tested Large amounts of accidentally spilled liquid are automatically collected in the gentleMACS Trough Use a pipette to aspirate the liquid before removing the Trough for cleaning and sterilizing If servicing of the gentleMACS Dissociator is required send the instrument back to a service provider authorized by Miltenyi Biotec Make sure that all parts are decontaminated and sterilized Use the original packaging material Always use your personal safety equipment while removing or disassembling parts of the gentleMACS Dissociator for cleaning or sterilization 8 Maintenance 39 40 Cleaning procedure For details on disassembly and reassembly see the picture below 1 2 Remove the Safety Shield Remove the Sleeves from the instrument for cleaning and or sterilization Remove the Trough for
42. tleMACS Program Card Select the destination on the gentleMACS Dissociator memory using the arrow buttons If there is already a program stored at the selected destination the name of this program is displayed If the destination is empty the line remains blank Press ok to store the program or press menu to cancel and select a different program If there is already a program stored at the selected destination confirm overwrite by pressing ok or cancel by pressing menu The program is being copied If an error occurs confirm the error message by pressing stop 6 Operating the gentleMACS Dissociator Delete a program 6 To delete a program from the gentleMACS Dissociator memory press the menu button until the delete menu is displayed Select Select the desired program using the arrow buttons If the gentleMACS Program Card is inserted remove the card If the gentleMACS Program Card is not inserted press ok Delete Program name Confirm Remove card Confirm the message to delete the 2 program by pressing ok or press menu to cancel and select a different program Delete Program name O S y The program is being deleted Program name The message will be displayed for Deleted 5 seconds Deleting Emergency shutdown procedure 1 Press the stop button 2 Press the mains switch at the back panel of the instrument 3 Unplug the instrument 6 Op
43. tor memory see the section Copy a program Select Select a program using the arrow buttons The selected program is displayed Program name Tube name gt Press start to run the program l Process is running The program Program name name and the remaining time are Run lt Time gt displayed If necessary cancel the process by pressing stop End Process finished successfully Program name gt The message is displayed End for 5 seconds Error If an error occurs during the Message run a message is displayed Confirm the error message by pressing stop 6 Operating the gentleMACS Dissociator 35 36 Select source Copy card Program name Remove card Select destination Destination lt gt Program name oo Destination lt gt Overurite oo v Copy done Confirm Copying Error x Message Copy a program To copy a program from the gentleMACS Program Card to the gentleMACS Dissociator memory insert the gentleMACS Program Card Press the menu button until the copy menu is displayed If the gentleMACS Program Card is not inserted a program from the gentleMACS Dissociator memory will be selected Select the desired program from the gentleMACS Program Card using the arrow buttons If a program is copied within the internal memory Copy memory is displayed instead of Copy card Press ok Remove the gen
44. werden Vorsicht Dieses Symbol deutet auf das Risiko der Besch digung des Ger ts bei Nichtbeachtung der Hinweise in diesem Handbuch hin Es wird dringend empfohlen die jeweiligen Kapitel in den entsprechenden Dokumenten zurate zu ziehen Schutzleiteranschluss Dieses Symbol ist innerhalb des Ger ts angebracht und stellt eine Warnung f r das Service Personal dar Ein Stromversorgung Aus Stromversorgung Warnhinweise und Vorsichtsma nahmen Dieses Kapitel enth lt Informationen die zur sicheren Handhabung des gentleMACS Dissociator beitragen sollen Ausf hrliche Sicherheitsinformationen sind im gesamten Handbuch zu finden und sind mit den oben gezeigten Symbolen gekennzeichnet Der Benutzer ist verantwortlich f r die korrekte Anwendung des gentleMACS Dissociator unter Beachtung der Anleitungen in diesem Handbuch sowie unter Beachtung s mtlicher relevanter Gesetze Eine fehlerlose und sichere Bedienung des Ger ts setzt voraus dass der Benutzer den Inhalt des Handbuchs versteht und alle Sicherheitsinformationen beachtet Bewahren Sie dieses Handbuch an einem sicheren Ort auf an dem es f r jeden Benutzer des gentleMACS Dissociator zug nglich ist Lokale Sicherheitsbestimmungen die den Arbeitsbereich betreffen Laborrichtlinien sowie Standards die die Laborsicherheit Gesundheit sowie die Unfallverh tung betreffen m ssen jederzeit eingehalten werden Im Falle sicherheitsrelevanter Defekte des Ger ts muss V
Download Pdf Manuals
Related Search
Related Contents
Trust Wall Charger with 2 USB ports - 2x12W Owner`s Manual For All HomeRight Hot Air Tools Petroleum Experts Télécharger le PDF - Auvergne Nouveau Monde GE AGH06 Air Conditioner User Manual Télécharger Rexel RM06179 149395-01I (479718 bytes) HP 1660CS-Series Logic Analyzers User`s Guide Samsung SPF-75H User Manual Copyright © All rights reserved.