Home
        Hardware Manual
         Contents
1.  PC  wipe it gently with a soft cloth dampened with either water or mild  detergent  Do not use chemicals or a volatile solvent  such as benzene or thinner  to prevent  pealing or discoloration of the paint     Do not use any sharp pointed object such as a mechanical pencil to touch the touch panel  Doing  so may scratch the touch panel  resulting in malfunctions     Do not subject the touch panel to shock as doing so may break it     When the surface or frame of the touch panel has become dirty  wipe it with neutral detergent  Do  not wipe the touch panel with thinner  alcohol  ammonia  or a strong chlorinated solvent  Use a  protective sheet  available as an option  if the touch panel is used where it can easily collect dust  and dirt     The touch panel may be damaged  if adhesive tape is applied and then peeled off its surface   The touch panel may be damaged  if a suction cup is applied and peeled off its surface     Do not use a cutter or steel wool to scrape foreign matter off the touch panel   Also  do not clean the touch panel with dry waste     Do not clean the touch panel with the waste which has been soaked in a strong chemical or  detergent  e g  acetone  xylene  toluene  general thinner  ketone solvent  acidic alkaline chemicals  and detergents  abrasive chemicals and detergents   or it may result in a stain or malfunction     When cleaning the touch panel  soak soft waste in water  squeeze it firmly  and use it on the surface  in a lightly rubbing motion  Do no
2.  The operating lifetime of the touch panel is at least 1 million touches  as  tested by mechanical touching under 1N of force at a rate of five presses  per second      4  Power supply   The expected battery life is 5 years in continuous operation at 40  C   However  the battery will not last as long  if used at a temperature  exceeding the operating temperature limit     5  Flash memory  NFDISK    The number of times of rewriting has restriction that is more   than 1 000 000   When the write size is 128KB or less     Since CF CARD is used for Flash memory  NFDISK   When  use is carried out for the use that rewrites frequently  be careful  of the number of times of rewriting    Moreover  when power supply OFF is done while writing it  data  in flash memory  NFDISK  might be damaged      CONTEC accepts your request for replacing each consumable in the PANECON PC as a request   for repair  at an additional cost       Be sure to turn off the power before plugging or unplugging any expansion board or connector      CONTEC reserves the right to refuse to service a product modified by the user      In the event of an abnormal condition or malfunction  please consult your retailer      Use an AC cable that is compatible with both the rated supply voltage and the receptacle      To connect with peripherals  use a grounded  shielded cable      This product contains a lithium battery as the primary cell and a cold cathode tube for the backlight   When disposing of the product  therefor
3. 14  PCMCTA PCMCTA  EE 15  UB ie sous areata ent waren ed 15   External Speaker Output Terminal ninia 16  TOUCH TE ico 16  Anal RGB VE sario ae 17  4 HARDWARE SETUP 19  Hardware e ie anene ATA EEEE TEA AE EAE TEE E 19  Thstallation  Requirements ds 20  Attaching the cover for this product  21  Attaching the PCMCIA card removal prevention Tnges   22  Back light     xchan iia 22  Attaching the USB cable removal prevention Clamps           c cssessceseseeseseeseeeeseeeseeeeseeeseeeeseereneees 23     CONTEC       PC PT020 Hardware Manual 111    Attaching the AC cable removal prevention clamps 25       Attaching  to the  VESA ATM aa 27  5 LIST OF OPTIONS 29  CONTEC    lv PC PT020 Hardware Manual    1  Before Using the Product    1 Before Using the Product  About the Product    This product is a panel computer based on Windows CE NET 4 2  which has an excellent  dustproof drip proof structure  It uses SH 4 with 128MB of memory as its CPU    The touch panel has an analog resistive glass glass style screen with excellent durability  The frame is  made of rust resistant stainless steel as well as in an IPX2 rated drip proof structure  The front side  has an IP65 rated dustproof and drip proof structure  This product comes with various expansion  interfaces such as USB  PC card  100BASE T and RS 232C interfaces  In addition  the product can be  mounted on an LCD arm  as it complies with the VESA standard     Features    SH 4 type CPU with 128MB of memory and rewritable erasable 128MB Fl
4. ESA 100mm standard allows you to install this product on an LCD  arm    System development support tool    CONTEC Manager    provided   This product comes with    CONTEC Manager     which helps you build a range of systems such as FTP  server function  scheduling function  NTP based automatic time adjustment function and Auto RUN  function           CONTEC  PC PT020 Hardware Manual 1    1  Before Using the Product    Customer Support    CONTEC provides the following support services for you to use CONTEC products more efficiently  and comfortably     Web Site    Japanese  http   www contec co jp   English http   www contec com   Chinese http   www contec com cn     Latest product information    CONTEC provides up to date information on products   CONTEC also provides product manuals and various technical documents in the PDF     Free download    You can download updated driver software and differential files as well as sample programs available in  several languages     Note  For product information    Contact your retailer if you have any technical question about a CONTEC product or need its price   delivery time  or estimate information     Limited One Year Warranty    CONTEC products are warranted by CONTEC CO   LTD  to be free from defects in material and  workmanship for up to one year from the date of purchase by the original purchaser    Repair will be free of charge only when this device is returned freight prepaid with a copy of the   original invoice and a Return Me
5. IPC Series    PANEL PC with  NET4 2 SH 4  20 Series    Hardware Manual    CONTEC CO  LTD        Check Your Package       Thank you for purchasing the CONTEC product   The product consists of the items listed below     Check  with the following list  that your package is complete  If you discover damaged or missing  items  contact your retailer     Product Configuration List    Pes  Pes   PANECON PC NN Attaching cover for the main body  a    PCMCIA card removal prevention fittings  1  CONTEC SDK for CE420         Screws for attaching the PCMCIA card EU Declaration of Conformity    removal prevention fittings    Three point sems screw  M3 x 6     AC power cable removal prevention clamp IPC Precaution List  USB cable removal prevention clamp EN Product guide EN  AC power cable     Notes  User s manual is not bundled with this product   it must be prepared by the user        Product Configuration Image    P y    PCMCIA card AC power cable    removal removal Attaching cover  prevention fittings prevention clamp for the main body       M    USB cable  removal  PANECON PC prevention clamp CONTEC SDK  for CE420  IPC    Precaution List    AC power cable  EU Declaration    of Conformity a P RR    Three point  sems screw       IPC Precaution List EU Declaration  of Conformity Product guide       CONTEC  PC PTO20 Hardware Manual i       Copyright  Copyright 2007 CONTEC CO   LTD  ALL RIGHTS RESERVED     No part of this document may be copied or reproduced in any form by any means without 
6. ash ROM   This product comes with SH 4 CPU   128MB of memory and Windows CE NET4 2  OS   It also has  a 128MB Flash ROM  which can be used as a user area and allow the user to write and erase user  programs    Whole frame in IPX2 rated drip proof structure  front side in IP65 rated dustproof drip proof structure  The whole frame is IPX2 rated and waterdrop proof  The front side is in an IP65 rated structure that  protects against dust and streams of water  For the touch panel  an analog resistive glass glass style  film with excellent durability has been adopted    Rust resistant stainless steel used for the cabinet   For the frame  rust resistant stainless steel has been adopted with a protection cover that protects the  interfaces against waterdrops    Expansion interfaces such as USB and PC card for PC standard   This product has two USB ports  a PC card slot  Type II x 2  or Type III x 1   100BASE T x 1   RS 232C x 2  analog RGB and stereo sound functions  The main frame has small built in speakers   which allow you to switch to external speakers  The analog RGB interface supports dual screen  display  This product also comes with the drivers required for the built in interfaces as standard  equipment    XIP ROM module enabling high speed startup as fast as approx  10 seconds   As the OS image is pre loaded in the XIP ROM  the OS can start as fast as about 10 seconds after  power up    Mounting structure supporting VESA 100mm standard   Mounting structure supporting the V
7. cifications    Functional Specifications  Table 2 1  Functional Specifications    IPC PTO20L8 AC 48  LCD type LCD type 12 1 inch TFT color LCD  800 x 600     Number of colors   65536    Touch panel 4096 x 4096  emulated in 800 x 600 mode   Resistive film analog glass glass type    PU SH 4  HD6417751RBP  Data  16KB  Instruction  32KB  Clock frequency  240MHz    Memory Flash memory 128MB   NFDISK     OS loading 32MB  Flash memory  COM port   RS 232C 2ch  COMI  16550  9 pin D SUB     COM2  16550  9 pin D SUB   Baud rate   50   115200bps    RTC The real time clock is accurate within  1 minutes  at 25  C  per month  DALLAS CO   LTD  DS12887A   10BASE T 100 BASE TX 1ch  NS CO   LTD  DP83816A   PC card slots PCMCIA Type II x 2 or Type HI x 1   EE   speakers   LED    Output terminals for external  3 5 Stereo mini jack Full scale output level 1 0Vrms  Typ      Built in speaker Rated input 0 3W  Connected to analog  L  signal of stereo output  DIPSW    Front function switch Front switch input   3 points  Front PowerLED 3 color display    Input power supply 100VAC  Input range  100V   240VAC 50VA    External RGB output Analog RGB output 15 pin HD SUB  Female  connector    About 3 6kg       1 Ineludes the attachments except cables           CONTEC  PC PT020 Hardware Manual 7       2  Overview    Installation Environment Requirements    Table 2 2  Installation Environment Requirements  Ambient specifications    Line noise Line noise AC line  2kV  resistance Signal line  1kV  EN61000 4 4 L
8. d at the specified voltage  Use of any other voltage level may cause  fire or electrical shock    This device must be properly grounded    Users should never disassemble or modify this device  or exchange components  This can cause  fire or electrical shock  In addition  the manufacturer is unable to repair products that have been  modified by the user    Procedures that could result in serious injury or loss of human life should never be performed from  a touch panel  Use system design methods that can guard against input errors           CONTEC       PC PT020 Hardware Manual 3    1  Before Using the Product    An CAUTION       Do not use or store the product in a location such as extremely high or low temperature  rapid  temperature changes  and the place which receives a strong ultraviolet ray   Example    Exposure to direct sun     In the vicinity of a heat source    Do not use the product in extremely humid or dusty locations    It is extremely dangerous to use the product with its interior penetrated by water or any other fluid  or conductive dust  If the product must be used in such an environment  install it on a dust proof  control panel  for example     Avoid using or storing the device in locations subject to shock or vibration     Do not use the product in the vicinity of devices that generate strong magnetic force or noise   Such devices will cause this device to malfunction     Do not use or store the product in the presence of chemicals     To clean the PANECON
9. e  treat it in accordance with the disposal regulations  stipulated by your local government      About VCCI class A  FCC PART15 class A  and EMC instruction class A incidental articles  This product acquires the above mentioned standard  and when an external speaker is used  an  enough margin might not be able to be secured  In that case  please install the ferrite core  SEIWA  E04SR200935A or interchangeable goods  in the speaker connection cable  Please shut after it  wraps it twice near the connector with the ferrite core opened when you install it          CONTEC  PC PT020 Hardware Manual 5       1  Before Using the Product    FCC PART 15 Class A Notice    NOTE    This equipment has been tested and found to comply with the limits for a Class A digital device   pursuant to part 15 of the FCC Rules  These limits are designed to provide reasonable protection  against harmful interference when the equipment is operated in commercial environment    This equipment generates  uses  and can radiate radio frequency energy and  if not installed and  used in accordance with the instruction manual  may cause harmful interference to radio  communications  Operation of this equipment in a residential area is likely to cause harmful  interference at his own expense     WARNING TO USER    Change or modifications not expressly approved the manufacturer can void the user s authority to  operate this equipment        CONTEC  6 PC PT020 Hardware Manual       2  Overview    2 Overview    Spe
10. evel3  IEC1000 4 4 Level 3     Static Contact discharge    4kV  EN61000 4 2 Level 2  IEC1000 4 2 Level 2     electricity Atmospheric discharge    8kV  EN61000 4 2 Level 3  IEC1000 4 2 Level 3   resistance    Vibration Anti shaking  10   57Hz semi amplitude 0 075mm  resistance One cycle  10 150 10 Hz  of 1oct min test at 9 8 m s   1G  between 57 an  150 Hz x 5 times in three  X Y Z  directions  40 minutes each      JIS C0040 compliant  IEC68 2 6 compliant     Impact resistance Tested with 11 ms half sine wave at 98 m s   10G  three times in each of  three  X Y Z  directions   JIS C0041 compliant  IEC68 2 27 compliant     Class D grounding  previous class 3 grounding  SG FG continuity  Water proof and dust proof  Whole frame   IPX2 compatible  in normal installation   Screen   IP65  2     1 When the total supply current of the USB connector exceeds 200mA  the Operating temperature of use becomes    0 40   C  Attaching cover for the main body         2 Please obtain the Attaching cover for the main body of appending to Water proof and dustproof     Table 2 3  Power Installation Environment Requirements    Power specifications    Allowable instantaneous 17ms or less  ACIN100V  Io 100   average value   AC2 0kV  between input and FG  10mA 1 minute  50MO  600VDC        IP Protection Ratings    IP Protection Ratings indicate levels of protection against intrusion by solid foreign substances and  water       IP65    This product does not allow entry of dust into it  It also does not a
11. fittings on the narrow square hole of the main body  as shown in the  following figure  and push it in so that the PCMCIA card is covered        Figure 4 4  Attaching the PCMCIA card removal prevention fittings  lt 1 2 gt   3  Secure the fittings at the upper end with the provided screw        Figure 4 4  Attaching the PCMCIA card removal prevention fittings  lt 2 2 gt     Back light exchange    The backlight used in the LCD module has a limited life  When it expires and requires replacement   contact your retailer        CONTEC  22 PC PT020 Hardware Manual    4  Hardware Setup    Attaching the USB cable removal prevention clamps    1  Connect the USB cable        Figure 4 5  Attaching the USB cable removal prevention clamps  lt 1 3  gt     2  Tie the USB cables together using the provided clamp for preventing USB cables from being  disconnected        Figure 4 5  Attaching the USB cable removal prevention clamps  lt 2 3  gt           CONTEC  PC PT020 Hardware Manual 23    4  Hardware Setup    3  Fix the USB cable removal prevention clamps to the main body as the following diagrams        Figure 4 5  Attaching the USB cable removal prevention clamps  lt 3 3  gt        CONTEC  24 PC PT020 Hardware Manual    4  Hardware Setup    Attaching the AC cable removal prevention clamps    1  Fix the AC cable removal prevention clamps        Figure 4 6  Attaching the AC cable removal prevention clamps  lt 1 4 gt     2  Connect the AC cable        Figure 4 6  Attaching the AC cable remova
12. i z   d E Geer    AS _ d L        La E  Von Tree te a 71   a  e o iS  Des       Ye   D X Dust cover  bundle    Nas ie  32 6  hE       mm                 Figure 2 2  Physical Dimensions       CONTEC    PC PTO20 Hardware Manual    10    3  Each Component Function    3 Each Component Function    Component Locations    Interface    The lower side of the back         POWER LAN    Sw ACN voa comz com INK CACT USB RST SPK Poncia      Leen TI TIO THI TIO TI I O                           SS                Bottom side       POWER  SW AC IN VGA COM2 COM1 LAN USB RST SPK PCMCIA    Front side             Function switch POWER LED    Figure 3 1  Component Locations       CONTEC  PC PT020 Hardware Manual 11       3  Each Component Function    Table 3 1  Component Identification    kass Joo          CONTEC    12 PC PTO20 Hardware Manual    3  Each Component Function    Component Identification    Serial Port Interface  COM1  COM2     The PANECON PC is equipped with two RS 232C compliant serial port connectors  Serial Port 1   COMI and Serial Port   COM2   Baud rate   50   115200bps    Table 3 2  COM1 COM2 Serial Port Inter Connector                                                                   Main unit connector D SUB 9 pin Male   1 5  No 4 40UNC  SE e Inch screw  9000  6 9  Pin No    Signal Function Direction  1 CD Carrier detection In  2 RD Recieved data In  3 TD Transmitted data Out  4 DTR Data terminal ready Out  5 GND Signal ground             6 DSR Data set ready M  7 RTS Request 
13. l prevention clamps  lt 2 4 gt           CONTEC  PC PT020 Hardware Manual 25    4  Hardware Setup    3  Tie the AC cables together using the AC cable removal prevention clamps from being disconnected   Then  push in the clamp and secure it firmly  as shown with the arrow in the following figure  so    that the clamp does not move        Figure 4 6  Attaching the AC cable removal prevention clamps  lt 3 4 gt     4  Be sure that the AC cable is fixed        Figure 4 6  Attaching the AC cable removal prevention clamps  lt 4 4 gt        CONTEC  26 PC PT020 Hardware Manual    4  Hardware Setup    Attaching to the VESA Arm    This product can be attached to the VESA standard 100mm arm   When attaching the VESA arm  note the following item       Load  Select the VESA arm of an enough load to the weight of this product       Installation angle   set it up to install the inclination of the back and forth on installation  requirements       For more details on the attaching method  refer to the VESA arm   s manual        CONTEC  PC PT020 Hardware Manual 27       4  Hardware Setup       CONTEC  28 PC PTO20 Hardware Manual    5  List of Options    5 List of Options    Manual    IPC PTO20L S HMJ   Hardware manual for IPC PTO20L S  AC series   Japanese     IPC SH4CE4 SMJ   Software manual  Japanese     IPC SH4CE4 SME   Software manual  English   Other    IPC SND 03   Desk stand  Notes  As the desk stand  IPC SND 03  is not made of stainless steel  care must be taken for its  use environmen
14. llow entry of water  from any direction  even when directly squirted on with a strong pressure       IPX2    The product is not badly affected by water dropped vertically from the top or within an  angle of 15 degrees        CONTEC  8 PC PT020 Hardware Manual    2  Overview    Display Optical Specifications    Table 2 4  IPC PT020LS AC 4E    View angle Gs  90   Monochrome 60deg 70deg   Horizontal    o  90      90   60deg 70deg  Display  Monochrome    Bright   pect Display  White 280cd m2 350cd m    at center   1     1 The surface brightness is a numerical value in the display unit  Brightness by which the touch panel is passed       becomes the above mentioned numerical value of about 84      Contrast ratio  CR    Brightness at screen center with white displayed       Brightness at screen center with black displayed    Z Measurement direction       Module       Right  Ge 90          Y    Figure 2 1  Definition of viewable range    An CAUTION    The above optical specification data shows optical characteristics of the liquid crystal in the display        the data does not represent the actual view on the display or its viewing angles              CONTEC  PC PT020 Hardware Manual 9    2  Overview    Physical Dimensions    IPC PTO20LS AC 4E             4 M4 TAP                                                                                                                                              Ni 303 56 5  gt   Maximum tapping length  5mm      100         E 6  ed oj ja  y 
15. ls     Table3 5  USB connector    E                               Pin No  Signal name  1  5V  2 DATA   3 DATA   4 GND            This product is bundled with the USB cable removal prevention cramp  For how to mount the  fittings  refer to Chapter 4    Hardware Setup              CONTEC  PC PT020 Hardware Manual 15    3  Each Component Function    External Speaker Output Terminal    Connector type   HSJ1456 010320 HOSIDEN     Table 3 6  External Speaker Terminal                               Pin No  Signal Remarks  1 GND Cl  2 Analog signal  R   Speaker  Right  O  3 Analog signal  L   Speaker  Left   1pin GND  2pin    R Analog signal    3    3pin L Analog signal  Applicable connector  Small jack of b3 5mm  Full scale output level 1 0Vrms  Typ      Notes  The built in speaker is connected to the analog signal  L   Therefore  when using the speaker   adjust the output balance between right and left by software  if necessary     If Jack is connected with the external speaker output terminal  an internal speaker is turned  off     Touch Panel    The PANECON PC is equipped with an analog touch panel that enables keyboard less  mouse less  Operations     Refer to the software manual for details on how to use the touch panel     Table 3 7  Touch panel specifications    This product  Detection method Analog resistive glass   glass type  Surface treatment    i 4096 x 4096  emulated in 800 x 600   Operating load Min 0 2N  Max 3N  1N 0 102kgf     Operating lifetime 1 million touches mini
16. mum        Load   1N  5 sec application  Tip shape   silicon rubber  p10mmR125        CONTEC  16 PC PT020 Hardware Manual    3  Each Component Function    Analog RGB I F    Simultaneous dual screen display is enabled  when an analog RGB display is connected to the Analog  RGB I F of this product     Table 3 8  VGA connector                                                                                                    Connector type 15 pin HD SUB  Female   5 1  S  84 if  900 0  o x me No 4 40UNC  Inch screw  15      Signal a Signal  Pin No  Pin No   name name  Bl RED 9 VCC  2 GREEN 10 GND  3 BLUE 11 N C   4 N C  12 N C   5 GND 13 HSYNC  6 GND 14 VSYNC  7 GND 15 N C   8 GND  Table 3 9  Analog RGB specifications  Display Dot Clock Horizontal Vertical HSYNC VSYNC  Dots Freguency   Freguency Freguency Polarity Polarity  800 x 600 40 0MHz 37 9KHz 60 1Hz Negative Negative                         Notes  The use of a liquid crystal display may cause disturbed images on the screen due to a  resolution problem  depending on the display to be connected   The display resolution is 800 x 600 SVGA  fixation           CONTEC  PC PT020 Hardware Manual 17    3  Each Component Function       CONTEC  18 PC PTO20 Hardware Manual    4  Hardware Setup    4 Hardware Setup    Hardware Setup      Make sure that the power is switched off before you start the operation       Do not remove any screws other than those explained here       As for the following items  be sure to setup     1  Attaching c
17. on of equipment and resources  Understand the meanings of these    labels to operate the equipment safely                 A DANGER DANGER indicates an imminently hazardous situation which  if not avoided  will  result in death or serious injury    A WARNING WARNING indicates a potentially hazardous situation which  if not avoided  could  result in death or serious injury    A CAUTION CAUTION indicates a potentially hazardous situation which  if not avoided  may  result in minor or moderate injury or in property damage              Handling Precautions    z       WARNING    Do not use this product in the presence of flammable or corrosive gases  This may lead to  explosion  fire  or damage to equipment    In the event of smoke  or abnormal smells or sounds  immediately turn OFF the power to this  device  disconnect the plug from the power outlet  and contact the manufacturer  Continued use  could lead to fire or electrical shock    Because of the danger of electrical shock or fire  do not contact this device  Other than the front  touch panel  while electrical current is present    Never touch this device or connectors with wet hands  This can cause electrical shock    Do not allow this device to come into contact with foreign substances  metal particles  flammable  substances  liquids  etc    This can cause fire or electrical shock    Do not place this device in an unstable location or use incomplete mountings  This may cause the  device to fall    This device must be operate
18. over for the main body   2 Attaching the USB cable removal prevention clamps   3  Attaching the AC cable removal prevention clamps   4 Attaching the PCMCIA card removal prevention fittings     CONTEC       PC PT020 Hardware Manual 19    4  Hardware Setup    Installation Requirements    When installing this product vertically  place the interface block at the bottom  To maintain the  ambient temperature within the installation environment requirement range  provide a gap of 50mm or  more between the main unit and any adjacent equipment    Also  use the product within an angle of 60 degrees  as shown in the following figure     4  A    Figure 4 1  Distances between the PANECON PC and Its Vicinity          15   60                              Figure 4 2  Installation permitted angle of the main body       CONTEC  20 PC PTO20 Hardware Manual    4  Hardware Setup    Attaching the cover for this product    1  Loosen the screws of the main body  as shown in the following figure        Figure 4 3  Attaching cover for the main body  lt 1 2 gt     2  Mount the bundled attaching cover for the main body by tightening the screws back  ensuring that  the cover contacts the body without any gap at the positions specified in the following figure        Figure 4 3  Attaching cover for the main body  lt 2 2 gt           CONTEC  PC PTO20 Hardware Manual 21    4  Hardware Setup    Attaching the PCMCIA card removal prevention fittings    1  Insert the PCMCIA card   2  Hook the right catch of the 
19. prior written  consent of CONTEC CO   LTD     CONTEC CO   LTD  makes no commitment to update or keep current the information contained in this  document     The information in this document is subject to change without notice     All relevant issues have been considered in the preparation of this document  Should you notice an  omission or any questionable item in this document  please feel free to notify CONTEC CO   LTD     Regardless of the foregoing statement  CONTEC assumes no responsibility for any errors that may  appear in this document or for results obtained by the user as a result of using this product     Trademarks    Intel and Celeron are registered trademarks of Intel Corporation  MS  Microsoft and Windows are  trademarks of Microsoft Corporation  Other brand and product names are trademarks of their  respective holder        CONTEC  ii PC PT020 Hardware Manual    Table of Contents       Check Your Package  COP ly AAA AA ii  Trad STH a r A ii  Table of Contents ien ee EE AER iii  1 BEFORE USING THE PRODUCT 1  About the Broderie it EE KEE AiR ENEE EEEREN 1  LC De 1  Customer SUP POL tose zaseklo TEESE EN 2  KEE 2  Limited A a 2  Howto Obtain  Service rosou 2  EE s NA na 2  Safety  Me e 3  Safety Information dE EENEG 3  Handling  Pre o NEEN ANEREN 3  2 OVERVIEW 7  o EN 7  External Dimensions    eiii 10  3 EACH COMPONENT FUNCTION 11  Component Loca A atid  11  Component Identification uerge 13  Serial Part Interface  GOM1   COM2  niaminini ar nav 13  ir LAV  N EEN 
20. rchandise Authorization to the distributor or the CONTEC group office   from which it was purchased    This warranty is not applicable for scratches or normal wear  but only for the electronic circuitry and  original products  The warranty is not applicable if the device has been tampered with or damaged  through abuse  mistreatment  neglect  or unreasonable use  or if the original invoice is not included  in  which case repairs will be considered beyond the warranty policy     How to Obtain Service    For replacement or repair  return the device freight prepaid  with a copy of the original invoice  Please  obtain a Return Merchandise Authorization number  RMA  from the CONTEC group office where you  purchased before returning any product       No product will be accepted by the CONTEC group without the RMA number    Liability   The obligation of the warrantor is solely to repair or replace the product  In no event will the  warrantor be liable for any incidental or consequential damages due to such defect or consequences that    arise from Safety Precautions   Understand the following definitions and precautions to use the product safely        CONTEC  2 PC PTO20 Hardware Manual    1  Before Using the Product    Safety Precautions    Understand the following definitions and precautions to use the product safely     Safety Information    This document provides safety information using the following symbols to prevent accidents resulting    in injury or death and the destructi
21. t      CONTEC       PC PT020 Hardware Manual 29    IPC PTO20LS AC 4E  Hardware Manual  IPC PTO20LS HME    CONTEC CO   LTD  November 2008 Edition    3 9 31  Himesato  Nishiyodogawa ku  Osaka 555 0025  Japan  Japanese http   www contec co jp    English http   www contec com    Chinese  http   www contec com cn     No part of this document may be copied or reproduced in any form by any means without prior written  consent of CONTEC CO   LTD   11072008      04192007  Management No A 51 387   11102008_rev6  Parts No  LYHC356    
22. t clean the touch panel with saturated material   It is  recommended to dry it immediately after cleaning      Use waste dedicated for cleaning lenses  e g  lens cloth  to clean the touch panel in a lightly rubbing  motion     It is a characteristic of analog touch panels that their resistance may vary with changes to the  ambient environment  temperature and humidity  and with their own aging  resulting in the  deviation of the detection point  If this is the case  calibrate the touch panel again to re set  calibration data        CONTEC  PC PT020 Hardware Manual    1  Before Using the Product      Burn in on TFT Display   Burn in  may occur if the same display is retained for a long time  Avoid this by periodically  switching the display so that the same display is not maintained for a long time      Burn In   Phenomenon characterized by a TFT display as a result of long time display of the   same screen where a shadow like trace persists because electric charge remains in the  LCD element even after the patterns are changed      Life expectancy of components    1  Battery   A lithium ion primary battery is used to back up the internal  clock calendar and CMOS RAM  The non energized backup time at  25  C is 10 years or more and at 60  C is 7 years or more     2  LCD backlight   Display brightness decreases over time with use    The operating lifetime of the backlight is 50 000 hours  the time until  the brightness is lowered to 50  of the initial value     3  Touch panel   
23. to send Out  8 CTS Clear to send In  9 RI Ring indicator In     CONTEC    PC PT020 Hardware Manual 13    3  Each Component Function                                                       Ethernet  LAN   Table 3 3  Ethernet connector  RJ 45   Connector type RJ 45  1 8  LINK ACT  Pin No  Singal name Function  1 TX  Transmitted data     output  2 TX  Transmitted data     output  3 RX  Received data     input  4 N C  Not connected  5 N C  Not connected  6 RX  Received data    input  7 N C  Not connected  8 N C  Not connected  LED indicator    LINK Green     Indicates the LINK status     ACT Orange     Indicates that data is being transmitted received when flashing        14    CONTEC  PC PTO20 Hardware Manual    3  Each Component Function    PCMCIA  PCMCIA     PCMCIA compliant card slots are provided  TYPE II x 2  TYPE III x 1  size            Slot 1                      Slot 2                Figure 3 2  Slot Numbers and Locations    An CAUTION      A type MI card should be inserted into slot 2          Incase of the CompactFlash Card  please use the PCMCIA conversion adapter          This product is bundled with the PCMCIA card removal prevention fittings  For how to mount the  fittings  refer to Chapter 4    Hardware Setup        Power Supply to the Card    The voltage that can be used and the current capacity of each slot are as shown below     Table 3 4  Power Supply to the Card    Current capacity  Max         USB port    The PANECON PC is eguipped with USB interface 2 channe
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Black & Decker EM200 Use & Care Manual  MMS-50I-N  PowerLogic Series 800 Power Meter Installation  1186 XML Reference.book - the Sitecore Developer Network    JPS Viewer Manual is here.  accura-expRACE KIT  User manual Car recorder Full HD (50206)  Philips Business 150B3M (White) 15" LCD Monitor  ZyXEL Communications 10~100 Series Network Router User Manual    Copyright © All rights reserved. 