1. Release Notes AB Allen Bradley Dynamix 2500 Data Collector Firmware Revision 1 020 Catalog Numbers 1441 DYN25 1441 DYN25 Z Topic Page Safety Information 1 Enhancements 2 Corrected Anomalies 3 Known Anomalies 6 Known Anomalies for the Emonitor Software 7 Operating System Update Procedures 8 Secure Digital SD Storage Cards 15 Dynamix 2500 Data Collector Kit Parts List 15 Additional Resources 15 Safety information Be aware of these safety precautions IMPORTANT Avoid Water The Dynamix 2500 data collector is splash and dust resistant However avoid direct contact with water wet surfaces or condensing humidity Keep this instrument away from wet locations for example laundry wet basements swimming pools If the data collector is subjected to these conditions adverse operation may result Before you use it let the Instrument dry thoroughly before operating collector on a solid stable surface when not in use and do not place any heavy objects on it Use only the accessories recommended by Rockwell Automation Keep liquids and foreign objects away from the instrument and never operate it if any liquid or foreign object has entered it ATTENTION To avoid damage or injury place the Dynamix 2500 data Optical Ports laser beam can expose your eyes beyond the maximum permissible exposure recommendations and cause harm ATTENTION When the laser on the data collector is active viewing the Laser Radiatio
2. or visit http www rockwellautomation com support Installation Assistance If you experience a problem within the first 24 hours of installation review the information that is contained in this manual You can contact Customer Support for initial help in getting your product up and running United States or Canada 1 440 646 3434 Outside United States or Use the Worldwide Locator at http www rockwellautomation com support americas phone_en html or contact Canada your local Rockwell Automation representative New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures United States Contact your distributor You must provide a Customer Support case number call the phone number above to obtain one to your distributor to complete the return process Outside United States Please contact your local Rockwell Automation representative for the return procedure Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA DU002 available at http www rockwellautomation com literature Allen Bradley Rockwell Software Rockwell Automation Dynamix 2500 Enpac 2500 Emonitor Datapac LASERTACH and TechConnect are tr
3. CORRECTED The number of characters that can be used to define route locations needs to be expanded You need to be able to manually change the font size on the data collector to reduce the amount of scrolling ICM00000915 CORRECTED Overall or Overall and Spec points can get marked with the wrong speed ICM00000924 CORRECTED Using an SD Card formatted as Fat32 you need to take two sets of data for the same route ICM00000933 CORRECTED The data collector collects Unfiltered Orbits only but not 1st Order 2nd Order for example no filtered orbits ICM00000935 CORRECTED The data collector always unloads a value of either 4 0882V when collected with an Orbit or 4 0868V when collected as a separate measurement This is regardless of the fact that the actual gap voltage is for example 9 987 or 10 023 ICM00000936 CORRECTED Low Frequency measurement reads lower than expected ICM00000937 CORRECTED Having a Ov Spec or RSS Control Point that is its own reference causes the point measurement to not be taken ICM00000938 CORRECTED The percentage change between last and current reading is displayed incorrectly when Chinese language is selected The workaround is to set the language to English and retake the measurement ICM00000941 S Aliasas 4401849600000 gt PA FAN 1 WTR OB HORIZ 1 Hor i zontal Normal data rx d Rockwell Automation Publication 1441 RN001B EN P September 2012 Dynamix 2500 Data Collector F
4. Click Yes if desired 5 Backup Modules Data Rockwell Automation Publication 1441 RN001B EN P September 2012 12 Dynamix 2500 Data Collector Firmware Revision 1 020 T You will be prompted also to back up Routes If backed up these are also automatically restored later in the firmware installation process Any Routes that are not backed up will be erased Click Yes if desired Installer Select l x Backup Routes e The loader goes through a series of backing up deleting and copying files Allen Bradley Dynamix 2500 OS Loader v1 02 build 13506 COPY_DIR RAPI Internal Disk SpindleTest Temp Internal Disk SpindleTest Asking user Backup Routes Skip if user selected No COPY_DIR RAPI Internal Disk pl302 Temp Internal Disk pl302 COPY_FILE RAPI Internal Disk pl302 config config p11 Temp Internal Disk pl302 config config p11 DELETE_FILE RAPI Internal Disk DELETE_FILE RAPI Internal Disk System Extensions exe Balance exe BumpTest exe FRF exe DELETE_FILE RAPI Internal Disk System extensions dll balancejob dll Balance_rc dll BumpTest_rc dll FRF_rc dll Recorder_rc dll RUCD_rc dll DELETE_FILE RAPI Internal Disk System Extensions bmp You will notice that the unit will reboot and ActiveSync will disconnect and reconnect Let the loader run through its processes Do not remove any cables or press any keys on the data collector Allen Br
5. RN001B EN P September 2012 We recommend that you upload your data to Emonitor before you update the Operating system just in case there is an error with the firmware installation such as a Dynamix 2500 Data Collector Firmware Revision 1 020 11 2 Connect your Dynamix 2500 data collector to the computer by using the splitter cable USB connection 3 Make sure the ActiveSync software is running 4 From the Start Menu choose Programs gt Allen Bradley gt Dynamix 2500 gt Dynamix 2500 OS Loader Handheld Firmware Installer F 7 x i NOTE installing the new Firmware may take 5 30 minutes depending on how much data you have which requires backing up and restoring 5 Click OK During the installation the Dynamix 2500 data collector restarts several times and multiple screens are displayed Disrupting or disconnecting the data collector from the computer causes the installation procedure to terminate and may leave the data collector in a corrupted state Allen Bradley Dynamix 2500 OS Loader v1 02 build 13506 Installer thread started Waiting for RAPI connection to be established RAPI connection established Wait You will be prompted to back up module data for example Run up Coast down measurements route database and measurement data You can choose to back up this data it is automatically restored later in the firmware installation process Any module data that is not backed up will be erased 6
6. you initialize before loading it also deletes the card files ICM00000872 The Dynamix 2500 data collector intermittently displays the message No Routes in Active Memory If the software initializes prior to loading routes the data collector intermittently displays the message No Routes in Active Memory This happens during the following sequence 1 Format a card for FAT32 in a card reader 2 Initialize the card in the data collector 3 Place the card back into the card reader to load routes This may be happening if you erase routes from the Secure Digital SD card via the Emonitor software If you see the intermittent message press Refresh on the data collector ICM00000873 Emonitor downloads the data twice plus SBA once data has been taken presumably because the alarms don t match between the Mag Spec If you remove the alarms from both or even just the Spec point then it looks like this point is loaded correctly ICM00000923 Two channel data works simultaneously if you set Lo Chan to 1 and 2 Adding a time point to the group changes the group from two channels to a single channel ICM00000934 When you take an Offroute orbit reading and unload it to Emonitor version 3 4 it will unload to Unscheduled The orbits graph in Emonitor looks completely different than in Dynamix 2500 ICM00000939 Rockwell Automation Publication 1441 RN001B EN P September 2012 8 Dynamix 2500 Data Collector Firmware Revision 1 020 Operati
7. 0760 CORRECTED If no previous data is set with the Emonitor software configured as undefined for the speed reference the instrument may not calculate speed correctly for dependant points ICM00000785 ICM00000782 CORRECTED The increase from 3 to 6 levels of hierarchy can make the navigation more complex due to the amount of data that must be scrolled through to confirm the point ICM00000787 CORRECTED Spectral peak displays as 3x higher than overall amplitude ICM00000798 CORRECTED The gSE Time waveforms can appear smoothed when compared to the Datapac 1500 data collector Occasionally gSE Time measurements are not taken correctly all Os The gSE Time waveforms are inverted ICM00000876 CORRECTED Overlapping band alarms do not trigger correctly ICM00000789 CORRECTED The Capture On Alarm works with only the first point after the Magnitude point ICM00000914 CORRECTED Filtered Orbits support up to 3x filtering All others will be taken and uploaded as Unfiltered ICMO00000935 CORRECTED The 1x RPM does not update cursors when in Continuous mode ICM00000913 CORRECTED When trying to set a high Fmax to measure gear mesh frequencies for example up to 80 kHz the unit may let you take the reading if you enter it with numeric keys ICMO00000802 CORRECTED When the route is collected the first two channel measurement is collected without errors During the second two channel measurement the error message er
8. UCD_Help WavSetup_0419 tet RockModules RUCD_HelpWavSetup_041D bet RockModules RUCD_HelpWavSetup_0804 txt RockModules RUCD_HelpWWavSetup_OCOA bet RockModules RUCD_rc dll COPY_DIR Internal Disk RuCd RAPI Internal Disk RuCd Demo_CoastDown way Demo_CoastDown_sg csv WARM_REBOOT RAPI connection closed Install complete Module Licensing Any modules that were licensed prior to the upgrade will still be licensed Any modules that are installed but which have not been licensed will appear grayed out as unavailable H S g DATA SETUP COLLECTION UTILITY is A FAF BUMP TEST FRF RECORDER A w 13 06 2012 Help About To activate grayed out modules contact your local Allen Bradley distributor or Rockwell Automation sales representative Use the table Data Collector Modules on page 8 to identify what modules you need to order IMPORTANT You will need to reenter the date and time in the data collector Rockwell Automation Publication 1441 RN001B EN P September 2012 14 Dynamix 2500 Data Collector Firmware Revision 1 020 TIP To confirm that the correct revision was loaded press F3 About on the Main Menu screen The firmware revision should match the operating system file just loaded Dynamix 2500 Data Collector nit ID 0000 001F 5D33 Upgrading the Emonitor Software The Dynamix 2500 data collector firmware revisions 1 010 and 1 020 are compatible with the E
9. ademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies Rockwell Otomasyon Ticaret A S Kar Plaza Ig Merkezi E Blok Kat 6 34752 erenk y Istanbul Tel 90 216 5698400 www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation NV Pegasus Park De Kleetlaan 12a 1831 Diegem Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Publication 1441 RN001B EN P September 2012 PN 173062 Supersedes Publication 1441 RNOO1A EN P May 2011 Copyright 2012 Rockwell Automation Inc All rights reserved Printed in the U S A
10. adley Dynamix 2500 OS Loader v1 02 build 13506 DELETE_DIR RAPI Internal Disk SpindleTest DELETE_DIR RAPI Internal Disk RuCd DELETE_DIR RAPI Internal Disk Balance CHECK_DISK_SPACE MOBM_BC bin EBOOT bin NK bin Sufficient memory available for upgrade 60 1252MB FORMAT RequestRegistryFormat COLD_REBOOT Waiting for RAPI connection to be established RAPI connection established Wait COPY_FILE FlashUtil new RAPI Windows SOURCE_MUST_EXIST FlashUtil new KILL_APPS Dynamix2500 COPY_FILE MOBM_BC bin RAPI Internal Disk SOURCE_MUST_EXIST MOBM_bc bin COPY_FILE EBOOT bin RAPI Internal Disk SOURCE_MUST_EXIST EBOOT bin COPY_FILE NK bin RAPI Internal Disk SOURCE_MUST_EXIST NK bin Rockwell Automation Publication 1441 RN001B EN P September 2012 Dynamix 2500 Data Collector Firmware Revision 1 020 13 8 Click OK Handheld Firmware instaler _ a d i OS installation complete Wait for the unit to reboot Installation is complete 9 Click Exit Allen Bradley Dynamix 2500 OS Loader v1 02 build 13506 RockModules RUCD_HelpWavSetup_O0407 txt RockModules RUCD_Help WavSetup_0409 tet RockModules RUCD_HelpWavSetup_O40B txt RockModules RUCD_Help WavSetup_O40C tit RockModules RUCD_Help WavSetup_0410 tet RockModules RUCD_HelpWavSetup_0413 txt RockModules RuCd_HelpWavSetup_0415 tet RockModules RUCD_HelpWavSetup_0416 txt RockModules R
11. irmware Revision 1 020 5 Table 3 Corrected Anomalies with Revision 1 010 Cat No Description 1441 DYN25 CORRECTED If you have band alarms that are overlapping then if one is triggered but the overlapping is not you will not see the 1441 DYN25 Z whole alarm band flashing as the untriggered alarm is painted over the triggered one 1441 PEN25 2C sides cal CORRECTED gSE Time measurements may not be taken correctly the instrument has displayed all zeros when you follow this sequence 1 Restart the instrument 2 Take a gsE Time Only point ICMO00000893 CORRECTED When using a Velocity probe both the Enpac 2500 data collector revision 2 02 and the Dynamix 2500 data collector revision 1 01 disables ICP power When using OffRoute and coupling set to ICP the unit does not actually turn on ICP power ICMO00000894 CORRECTED If connected to a Speed Ref POINT the Spectrum POINT is downloaded with the wrong speed value This speed value is based on the previously uploaded Speed If this POINT is attached to a Speed Ref POINT it should update to the newly measured speed and then upload to the Emonitor software with the new value ICM00000895 CORRECTED When you setup an OffRoute gSE POINT with Display Format Time and 2 kHz filter with 500 Hz Fmax the gSE time waveforms are inverted If you apply a Burst signal with a carrier of 1 kHz and Burst of 10 cycles and 50 ms 20 Hz you may see that the spikes in the time waveform are going
12. lder To install in this folder click Next To install to a ditferent folder enter it below or click Browse Folder C Program Files Allen Bradley Dynamix2500 OS Loader Browse Disk Cost Install Dynamix2500 OS Loader for yourself or for anyone who uses this computer Everyone C Justme ma e 3 Select an installation folder and click Next ie Dynamix2500 OS Loader Confirm Installation The installer is ready to install Dynamix2500 OS Loader on your computer Click Next to start the installation coc coun The 4 Click Next Rockwell Automation Publication 1441 RN001B EN P September 2012 10 Dynamix 2500 Data Collector Firmware Revision 1 020 5 Install the Dynamix 2500 Data Collector Firmware This procedure details the steps necessary to reinstall or upgrade your data collector s firmware by using the Dynamix 2500 OS Loader application TIP ii Dynamix2500 OS Loader Installing Dynamix2500 OS Loader Dynamix2500 OS Loader is being installed Please wait The loader is installed The installation is complete ji Dynamix2500 OS Loader Installation Complete Dynamix2500 OS Loader has been successfully installed Click Close to exit Click Close cable disconnect Follow these instruction to install the firmware 1 Apply power to the data collector Rockwell Automation Publication 1441
13. monitor software revision 3 4 and later For instructions on how to upgrade your Emonitor software refer to one of the Emonitor installation manuals Table 6 Emonitor Installation Manuals Publication Emonitor Gupta Single User Installation Manual Emonitor Gupta Multi User Installation Manual Emonitor Oracle Multi User Installation Manual Emonitor MSSQL Multi User Installation Manual Publication Number EMONTR IN001 EMONTR IN002 EMONTR IN003 EMONTR IN004 Rockwell Automation Publication 1441 RN001B EN P September 2012 Secure Digital SD Storage Cards Dynamix 2500 Data Collector Kit Parts List Additional Resources Dynamix 2500 Data Collector Firmware Revision 1 020 15 The Dynamix 2500 data collector stores program information and data ona Secure Digital SD card The unit is configured to accept a standard SD card gt 4 GB that is supported with a Microsoft Windows CE driver You can insert the SD card into the instrument when it is powered on or off IMPORTANT The Dynamix 2500 data collector is only certified for use with the sandisk Secure Digital Card SDSDx yyy See the Dynamix 2500 Data Collector User Manual publication 1441 UMO001 for a complete parts list This publication is also on the product CD ROM These documents contain additional information concerning products from Rockwell Automation Resource Description Dynamix 2500 Data Collector User Describes configuring the data connector se
14. n Ports system is open and interlocks bypassed Only trained and qualified ATTENTION Class 1 laser product Laser radiation is present when the AN personnel should be allowed to install replace or service the instrument Rockwell Allen Bradley Rockwell Software Automation 2 Dynamix 2500 Data Collector Firmware Revision 1 020 i Fnhancements This table lists the enhancements that are provided with the Dynamix 2500 data collector revision 1 020 Table 1 Enhancements with Revision 1 020 Cat No Enhancement j 1441 DYN25 A Set up menu option for Module ICP is available 1441 DYN25 Z Route Mem Internal Timeout Ort Trigger External Dft Units English Date Format a Time Zone GMT 05 003 Ea Date Time 11 17 12 09 2012 Memory select cmd Route Font Big Envelope QSE Navigation DataPac Transducer Chan Warn Bias Check Manual Module ICP Language Rockwell Automation Publication 1441 RN001B EN P September 2012 Dynamix 2500 Data Collector Firmware Revision 1 020 3 Corrected Anomalies This table lists the corrected anomalies with the Dynamix 2500 data collector i revision 1 020 Table 2 Corrected Anomalies with Revision 1 020 Cat No Description 1441 DYN25 CORRECTED The data collector does not recognize user defined units 1441 DYN25 Z ICM00000755 CORRECTED The data collector freezes when collecting data on a Secure Digital SD card for two continuous hours ICM0000
15. negative rather than positive ICMO0000896 CORRECTED The first time you delete a measurement from Review you get a TourDB error and it isn t deleted although the tick mark vanishes but if you delete it again it disappears ICMO00000897 CORRECTED When taking an Orbit measurement the default view shows the correct rpm If you change to the Time View using the View Menu then the incorrect rom is shown The Orbit view is correct and is showing what is actually measured and stored ICMO00000898 CORRECTED If you take a measurement with Frequency Items where the Speed is taken from a previous POINT for example rpm then the Frequency Items are incorrectly drawn in the FFT They appear to get correctly drawn after the POINT has been stored for example they are correct in Review ICMO00000899 CORRECTED he Machine Speed Auto setting should default to behave like Slow when the associated rpm has less than 600 rom Auto may only behave like Slow when the speed drops below 200 rpm but this is too low 3 33 Hz ICMO0000900 CORRECTED When setting the following parameters OffRoute and applying a 60 Hz sine wave at 100 mV Pk with a 1V DC offset Accel g DC Coupling Peak Detection Filter OFF 400 Hz Fmax You will get these results e Overall 23 1 g e 0 Hz bin 20 1 g e 60 Hzbin 1g ICM00000901 CORRECTED Orders based measurements collect as if the Fmax is based on the speed downloaded from the Emonito
16. ng System Update Procedures Download the Dynamix 2500 zip upgrade file from http www rockwellautomation com support Choose Downloads gt Firmware Updates gt Condition Monitoring IMPORTANT We recommend that you delete all older versions of the installer loader msi files from your computer before updating the Dynamix 2500 data collector s operating system You can load the operating system firmware from Dynamix 2500 data collector product CD by using the USB connection Use the Dynamix 2500 OS Loader application on the product CD or at hetp www rockwellautomation com support firmware html To use the Dynamix 2500 OS Loader application the following must be installed on your computer e Microsoft s ActiveSync software Communication is supported through the USB port by using Microsoft ActiveSync software version 4 5 or later If you have not installed ActiveSync software see Install ActiveSync or Mobile Device Center Software in the Dynamix 2500 Data Collector User Manual publication 1441 UM001 for more information e USB Drivers If you have not installed the USB drivers for your Dynamix 2500 data collector see Installing the USB Drivers in the Dynamix 2500 Data Collector User Manual publication 1441 UMO001 IMPORTANT Whenever you rerun the OS Loader software you will reload only the main OS firmware The OS loader will back up licence files and data but not the optional extension modules Once you have updated
17. ore complex due to the amount of data that must be scrolled through to confirm the point ICM00000787 The Speed Reference function from a spectrum is not supported ICM00000795 When trying to set a high Fmax to measure gear mesh frequencies for example up to 80 kHz the unit may let you take the reading If entering with numeric keys ICMO00000802 When you measure gear mesh frequencies above 20 KHz you will not be able to see a 2x 40 KHz gear mesh frequency Emonitor software version 3 4 does not support gt 40 KHz on the Dynamix 2500 data collector or the Enpac 2500 data collector ICMO00000806 IS02954 is not fully supported with the Dynamix 2500 data collector or the Enpac 2500 data collector ICM00000807 You may find that the option to Unload All Measurements when following this sequence 1 Load a route from Emonitor software version 3 4 with HF090525 applied via USB connection 2 Take multiple readings 3 Select Unload all and view multiple measurements for the route point 4 Load a route from Emonitor software version 3 4 with HF090525 applied 5 Take multiple readings The Unload All Measurements setting cannot be selected ICM00000826 When taking a reading with the wrong filter selected the OA Power Bar does not display when taking a reading ICM00000845 If the SD card is in the data collector and is set to Internal memory it sees the routes loaded via the USB connection for both the card and internal memory If
18. r software so changing the actual speed does not change the Fmax used for the measurement ICM00000902 Rockwell Automation Publication 1441 RN001B EN P September 2012 6 Dynamix 2500 Data Collector Firmware Revision 1 020 Table 3 Corrected Anomalies with Revision 1 010 Cat No 1441 DYN25 1441 DYN25 Z 1441 PEN25 2C Description CORRECTED Measurements are collected with the wrong Fmax for Orders points with speed set by a Control Point If a point is set up as Orders but with the speed coming from a Control Point then in many cases the measurement is taken with the incorrect Fmax that makes the frequencies labeled incorrectly ICM00000903 CORRECTED Downloading a route where the first point is unsupported and can give TourDB errors even though the invalid point is not downloaded and require a soft restart ICMO00000904 CORRECTED If there is a point with a Magnitude and Spectrum collection and you are using an Analog Filter then it is possible for the Spectrum Peak to be much larger than the Overall especially if the measurement is Integrated ICMO00000905 Kn own Anoma I ies This table lists the known anomalies for the Dynamix 2500 data collector revision 1 020 Table 4 Known Anomalies with Revision 1 020 Cat No Description 1441 DYN25 Automatic amplitude ranging may take a long time Data might be missed 1441 DYN25 Z ICMO00000808 When the route is collected the first two channel measurement is collected
19. ror retrieving information from database appears and the route locks up ICM00000815 CORRECTED The data collector fails to recognize a change in collection specifications for example spectral data with different Fmax The collector takes data but uses only one Fmax ICM00000818 CORRECTED When you load a magnitude phase measurement point with a collection spec that has more than eight orders and then attempt to load to the collector it does not load the measurement point The error message Unsupported Measurement ICMO00000825 CORRECTED The data collector cannot extract speed from the spectrum if the magnitude reading is taken first To avoid this Situation create a Location ID with a magnitude measurement point prior to a spectrum measurement point ICM00000834 CORRECTED When taking a reading with the wrong filter selected the OA Power Bar is not displayed when taking a reading ICMO00000845 CORRECTED When you have band alarms that are overlapping and one is triggered but the overlapping alarm is not you will not see the whole alarm band flashing as the untriggered alarm is painted over the triggered one ICM00000848 CORRECTED The frequency item order reference is not always the motor speed reference Although the time waveforms have the correct speed for the motor locations the speed increased or reduced locations have an incorrect speed on just the waveforms The ratio multiply relationship is not used and the waveform
20. the OS firmware install the latest version of your optional extension modules Before performing the 1 020 firmware upgrade take note of the modules installed on the Dynamix 2500 data collector TIP To confirm which modules are installed and the version press F3 About on the Main Screen Table 5 Data Collector Modules Cat No Version 1441 DYN25 MBAL Balancing Upgrade 1441 DYN25 MBMP Bump Test 1441 DYN25 MFRF FRF Frequency Response Function 1441 DYN25 MREC RuCD RunUp CoastDown 1441 DYN25 MRUC Recorder Rockwell Automation Publication 1441 RN001B EN P September 2012 Dynamix 2500 Data Collector Firmware Revision 1 020 9 Install the Dynamix 2500 OS Loader Application 1 Double click the Dynamix 2500 Dynamix2500_OS_Loader_v1 02 13506 msi file on your computer i Dynamix2500 OS Loader Welcome to the Dynamix2500 OS Loader Setup T Wizard AXA he The installer will guide you through the steps required to install Dynamix2500 OS Loader v1 02 13506 on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law 2 Click Next i Dynamix2500 OS Loader Select Installation Folder ee A The installer will install Dynamix2500 OS Loader to the following fo
21. tting up Manual publication 1441 UM001 measurements collecting and reviewing data and loading and unloading data Emonitor User s Guide publication Describes data management for predictive maintenance EMONTR UMO01 SErVICES Industrial Automation Wiring and Provides general guidelines for installing a Rockwell Grounding Guidelines publication Automation industrial system 1770 4 1 Product Certifications website Provides declarations of conformity certificates and http www ab com other certification details You can view or download publications at http www rockwellautomation com literature To order paper copies of technical documentation contact your local Allen Bradley distributor or Rockwell Automation sales representative Rockwell Automation Publication 1441 RN001B EN P September 2012 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products At http www rockwellautomation com support you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make the best use of these tools For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative
22. uses the motor speed for Its rom value ICM00000849 Rockwell Automation Publication 1441 RN001B EN P September 2012 4 Dynamix 2500 Data Collector Firmware Revision 1 020 Table 2 Corrected Anomalies with Revision 1 020 Cat No 1441 DYN25 1441 DYN25 Z Description CORRECTED There is no power for accelerometer with velocity output when displaying reading in mils ICM00000850 CORRECTED Option for printing to SD card is lost ICM00000861 CORRECTED The data collector is unable to support DC Bias Trending in Route mode when taking readings from a switch box These readings require the instrument to power the transducer ICMO00000862 CORRECTED Order based measurements collect as if the Fmax is based on the speed downloaded from the Emonitor software so changing the actual speed does not change the Fmax used for the measurement ICM00000902 ICM00000870 CORRECTED If a enter key is pressed before the data collector starts the Initialize process the unit locks up and must be warm booted If the enter fire key is pressed before Splash Screen has completed the data collector will lock up during the power cycle ICM00000875 CORRECTED When the Balancing Extension Module defaults to External Trigger a LASERTACH option is needed ICMO00000880 CORRECTED When a motor is going slow the rpm on the screen does not display the proper value When changing speeds the rom does not change to match the motor speed ICM00000882
23. without errors During the second two channel measurement the error message error retrieving information from database appears and the route locks up ICM00000815 Channel 2 previous values do not download on cross phase POINTs If you take a cross phase POINT then the Channel 2 previous value does not load correctly so the overall bar shows a 100 change ICM00000910 Offroute does not take displacement from Accel in Time format ICM00000921 When taking an integrated measurement by using the Conservative Autoranging setting you may notice a measurement that is 15 lower than expected To avoid this lower reading use the Aggressive or Fixed Autoranging setting to get consistently correct results ICM00000942 Rockwell Automation Publication 1441 RN001B EN P September 2012 Dynamix 2500 Data Collector Firmware Revision 1 020 7 Kn own Anomalies for the This table lists the known anomalies for the Emonitor software that affects the Dynamix 2500 data collector revision 1 020 and earlier Emonitor Software Cat No Description Emonitor If no previous data is set with the Emonitor software configured as undefined for the speed reference the instrument may not calculate speed correctly for dependant points ICM00000785 ICM00000782 You may not see the overall amplitude versus a time plot prior to collecting data starting on measurement point ICM00000783 The increase from 3 to 6 levels of hierarchy can make the navigation m