Home

instructions guide and user manual wall mount hoods.

image

Contents

1. held responsible for any damages to per sonal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood Table of Content INSTALLATION Tools needed Parts supplied Venting requirements Mount heights amp clearance Venting methods amp Re calculating functions Charcoal Filter Installation Electrical Requierements Preparations Installation Tools Needed rie OV ul amp W O CO ON USE AND CARE Range hood operations Troubleshooting Use and care information Specifications MAINTENANCE Cleaning replacing filter amp light bulb WARRANTY Warranty Coverage amp exceptions 11 12 13 14 15 15 16 17 18 Parts supplied Lower Standard Chimney B A Qty 1PCS Qty 2PCS C Qty 1PCS D amp Qty 4PCS eR TIE Support frame extension Length varies with ceiling heigh Main Unit Grease Oil Cup Range Hood Vary By Model Upper Standard Chimney Air Diverter Optional re circulating kit pre installed when ordered together with range hood Charcoal filter Optional re circulating kit pre installed when ordered together with range hood Venting Requirements e Vent system must terminate to the outside roof or side wall e DO NOT terminate the vent system in an at tic or other enclosed area e DO NOT use 4 10 2 cm laundry type wall Caps e Use metal aluminum vent only
2. liquid degrease such as Formula 409 or Fantastic brand cleaner e If hood looks splotchy stainless steel hood use a stainless steel cleaner to clean the surface of the hood Avoid getting cleaning solution onto or into the control panel Follow directions of the stainless steel cleaner CAUTION Do not leave on too long as this may cause damage to hood finish Use soft towel to wipe off the cleaning solution gently rub off any stubborn spots Use dry soft towel to dry the hood e After cleaning you may use non abrasive stainless steel polish such as 3M or ZEP to polish and buff out the stainless luster and grain Always scrub lightly with clean cotton cloth and with the grain e DO NOT allow deposits to accumulate or remain on the hood e DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting e DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after exposure and wipe dry with a clean cloth 16 Cleaning Aluminum Grease Filter Stainless Steel Filter less Grill A WARNING e Failure to observe the instructions on cleaning the unit and changing the filters could cause a fire hazard You are therefore strongly recommended to follow these instructions e The manufacturer declines all
3. marks drill two holes appropriate for heavy duty wall anchors and screws not included Mount the range hood on the wall with the two screws and anchors and tighten 3 Install the one way valve on top of the range hood and assemble the exhaust pipe and decorative cover 4 Affix the decorative cover with two M4 tapping screws on the hood body 5 Make sure all switches are off and then insert the electrical plug into an outlet Technical Parameters Rated Voltage Rated frequency Motor input power Lamp power Air volume 9 5 15 Air pressure gt 160 Noise level 10 Range Hood Operations Controls Control Panel Layout and Buttons Configurations for models Grecia Paris Venice Pro Infrared ray receiver Power key Time setter Lamp key Down key Up key Power off delay timer indicator Power indicator Light power indicator Speed indicator Delay digital timer indicator Button functions Infrared ray Receiver the range hood for the infrared receiving window Timer Setter time Setting ON OFF control the range hoods working time Down Key Blower motor speed decrease timer value decrease and enter timer mode Up Key Blower motor speed increase timer value increase and cumulative timer reset Lamp Turns ON OFF and dim halogen lights Power Power ON OFF the range hood and activate power off delay timer Power Off Delay Timer Indicator Lights up when auto shutdown delay timer function is on Light Power Indicato
4. purchased the range hood with re circulating kit from us 1 Remove aluminum filters on hood 2 Position the charcoal filter or filters depending on model onto each side of the motor and turn until it locks Re install aluminum filters 3 Charcoal filters must be replaced after 120 hours of use or approximately every 2 to 3 months based on the average of 1 to 2 hours of daily cooking time Available online only at www lecappe com Electrical Requirements It is the customer s responsibility e To contact a qualified electrical installer e To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A 120 Volt 60 Hz AC only USA amp Canada standard fused electrical supply is required on a separate 15 amp circuit fused on both sides of the line DO NOT ground to a gas pipe Check with a qualified electrician if you are not sure that the range hood is properly grounded DO NOT have a fuse in the neutral or ground circuit IMPORTANT Save this Installation Guide for electrical inspector s use The range hood must be connected with appropriate wire plug only The range ho
5. responsibility for any damage to the motor or any fire damage linked to Inappropriate maintenance or failure to observe the above safety recommendations Changing The Light Bulb e Disconnect the cooker hood from the mains supply e Remove the lamp cover use a screw driver as a lever Fig 5 e Replace the old bulb with a new one of the same type e Refit the lamp cover e If the light does not come on make sure the bulb has been inserted in correctly before contacting your local AEG Service Force Centre Fig 5 17 Le Cappe One Year Limited Warranty Please provide an original dated proof of purchase sales receipt invoice in order to obtain service under warranty One Year Parts warranty For one year from the date of original purchase your local reseller will provide free of charge non consumable replacement parts or components that failed due to manufacturing defects Subject to the conditions and limitations set forth below your local reseller will at its option either repair or replace any part of its products that prove defective by reason of improper workmanship or materials Repaired parts or replacement products will be provided by your local reseller on an exchange basis and will be either new or refurbished to be functionally equivalent to new The consumer is responsible for all shipping costs Con sumable parts not covered by this warranty include but not limited to Light bulbs metal aluminum and cha
6. INTERNATIONAL INSTRUCTIONS GUIDE AND USER MANUAL WALL MOUNT HOODS TTT UL IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference Important Safety Notice Read all Instructions before installing and operating this appliance e The installation in this manual is intended for qualified installers service technicians or persons with similar qualified background Installation and electrical wiring must be done by qualified professionals and in accor dance with all applicable codes and standards including fire rated construction e DO NOT attempt to install this appliance yourself Injury could result from installing the unit due to lack of appropriate electrical and technical background e Range hood may have very sharp edges please wear protective gloves if it is necessary to remove any parts for installing cleaning or servicing e Activating any switch ON before completing installation may cause ignition or an explosion e Due to the size and weight of this range hood two people installation is recommended To reduce the risk of fire electric shock or injury to persons e For general ventilating use only DO NOT use to exhaust hazardous or explosive materials and vapors e The combustion air flow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating eq
7. Rigid metal Not Included aluminum vent is recommended e DO NOT use plastic vent eAlways keep the duct clean to ensure proper airflow e Calculate the following figures before installation 1 Distance from the floor to the ceiling 2 Distance between the floor to the coun tertop stove Usually 36 Inches 3 Distance between the countertop stove to the range hood We recommend 25 5 to 27 1 2 Inches 4 Height of hood and duct cover For the most efficient amp quiet operation e It is recommended that the range hood be vented vertically through the roof through 6 15 24 cm or bigger round metal aluminum vent work e The size of the vent should be uniform e Use no more than two 90 elbows e Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used e DO NOT install two elbows together The length of vent system and number of elbows should be kept to a minimum to pro vide efficient performance e The vent system must have a damper If roof or wall cap has a damper DO NOT use damper if supplied on top of the range hood e Use silver tape or duct tape to seal all joints in the vent system e Use caulking to seal exterior wall or roof open ing around the cap Height amp Clearance Support Structure Maximum ceiling clear ance 106 at 27 5 hood mounting height above countertop stove may vary eal w
8. ck if all joints are properly connected sealed and taped Make sure the power is on high speed for heavy cooking e These slots holes openings are used to exhaust cleaned air with optional re circulating kit If you did not install one you do not need them Use and Care Information Operations e Read and understand all instructions and warnings in this manual before operating the appliance Save theseinstructions for future reference e Always leave safety grills and filters in place Without these components operating blowers could catch on to hair fingers and loose clothing e NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers e NEVER leave cooking unattended When frying oil in the pan can easily overheat and catch fire The risk of self combustion is higher when the oil has been used several times e NEVER cook on open flames under the range hood Check deep fryers during use Superheated oil may be flammable Cleaning e The saturation of greasy residue in the blower and filters may cause increased inflammability Keep unit clean and free of grease and residue build up at all times to prevent possible fires e Filters must be cleaned periodically and free from accumulation of cooking residue see cleaning instruc tions on Page 17 Old and worn filters must be replaced immediately e DO NOT operate blowers when filters are removed Never disassemble parts to clean without p
9. et metal screws and tape all joints with certified Silver Tape or Duct Tape e Use caulking to seal exterior wall or roof opening around the cap Not included Option 1 vertical tooi i A Option 2 Horizontal wall venting venting wa Le Roof cap ee i a ee _ i i i L f a ae a a Side wall cap oO j i i j i i i i i i i i a i i i i i ES Re Circulating Function Methods Re circulating function is intended for applications where an exhaust duct work is not possible to be installed When converted the hood functions as a purifying hood rather than an exhaust hood Fumes and exhaust from cooking is drawn and filtered by a set of charcoal filters The air is then purified and re circulated back within the home e We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work if possible Only when the exhaust option is not possible should you recourse to converting the hood into a purifying unit e When converted to be a purifying unit a charcoal filter is required in addition to its standard aluminum filter set Available online only The standard aluminum filters are intended to capture residue from cooking the optional charcoal filters help to purify fumes exhausted from cooking Charcoal Filter Installation NOTE The charcoal filter or filters are required when using the LeCappe hood as a purifying unit only if you
10. fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency e If available also refer to stove top manufacturer s height clearance requirements and recommended hood mounting height above range Due to different ceiling height configurations recommended height may not be applicable Minimum Duct Size e Round 6 minimum e Rectangular 3 1 4 x 10 minimum requires a 6 to 3 1 4x10 adaptor not supplied To calculate the length of the system you need deduct the equivalent feet for each vent piece used in the system from the recommended maximum duct run Duct Run Calculation R6 or 3 1 4 x 10 duct 30 ft Vent piece deduction Each 90 elbow used Each 45 elbow used Duct Run Calculation example Pr O f cap 90 elbow and 45 elb Each 6 to 3 14 x 10 transition used can Gad es Att ha H ene ete Side wall cap with damper Deduct 14 ft from 30ft 16ft maximum available for Straight duct run If no elbows are used maximum Venting Methods This range hood is factory set for venting through the roof or wall e Vent work can terminate either through the roof or wall To vent through a wall a 90 elbow is needed IMPORTANT e NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside e Use metal aluminum duct work only e Fasten all connections with she
11. g servicing installing or determining the source of problems with this product This warranty is valid in the country of the original purchase at retail It is non transferable and applies only to the original purchaser and does not extend to subsequent owners of this product Any applicable implied warranties including the warranty of merchantability are limited in duration to a period of express warranty as provided herein beginning with the date of original purchase at retail and no warranties whether express or implied shall apply to this product thereafter To obtain warranty service you may contact your local reseller from which you purchased this product Please confirm the terms of your local reseller s policies prior to contacting Typically you must include product identification information including model number and serial number with a detailed description of the problem you are experiencing You must include proof of the date of the original retail purchase as evidence that the product is within the applicable warranty period The information in this document is subject to change without notice please contact your local reseller for updated details 18
12. he slots holes openings near the top of the upper chimney nne t eT main as ical ERY b efore ervicing this dev electrical c Seren o tri cal c ci ircuitry inside this range the e Hazard of electrical shock Do not perfor rms ce o electrically liv ctric uchin wy ergized could re clay fag a r proper e Check if the range hood has been plugged in make sure that all power has been turned back ON fused not blown and all electrical wiring are properly connected e Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs e The range hood might not have been secured Properly on to the ceiling or wall Check with your installer e Check that the duct sized used is at least 6 or 3 1 4 x 10 Range hood WILL NOT function efficiently with insufficient duct size For example 7 duct over 6 hole and loosely secured e Check if duct is clogged or if damper unit half cir cular flapper is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow e The blower might be jammed or scraping the bottom due to shipping damage Please contact us immediately e Make sure the distance between the stove top and the bottom of the hood is within 28 and 31 in distance Due to different ceiling height configura tions recommended height may not be applicable Reduce the number of elbows and length of duct work Che
13. ith different model Aceh Chimney Chimney extensions available for higher ceiling Extension available Support Structure Standard Lower Chimney Extension available Range hood s 7 Min 25 5 Max 27 5 Max 101 36 base e A minimum of 6 round standard for this range hood or 3 1 4 x 10 rectangular duct purchased sepa rately must be used to maintain maximum airflow efficiency e Flexible 6 round duct always use rigid type metal aluminum ducts if available to maximize airflow when connecting to provided duct e Please use Duct Run Calculation below to compute the total available duct run when using elbows transitions and caps e ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long reducer instead of a pancake reducer e Reducing duct size will restrict airflow and decrease airflow thus reduce duct size as far away from opening as possible e If turns or transitions are required Install as far away from opening and as far apart between 2 as pos sible e Minimum mount height between stove top to hood bottom should be no less than 28 inch e Maximum mount height between stove top to hood bottom should be no higher than 31 inch e It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and
14. ntrols Control Panel Layout and Buttons Configurations for models Messina amp Athenas See your specific model Lamp on off Power amp Delay on off High speed on off Low speed on off Middle speed on off Button functions Lamp Turns ON OFF and dim halogen lights Power amp Delay Power ON OFF the range hood and activate power off delay timer Low Speed Blower motor speed decrease timer value decrease and enter timer mode Middle Speed Blower motor speed increase timer value increase and cumulative timer reset High Speed Blower motor speed increase timer value increase and cumulative timer reset power Low speed on off high speed on off Lamp on off middle speed on off Button functions Lamp Turns ON OFF and dim halogen lights Power amp Delay Power ON OFF the range hood and activate power off delay timer Low Speed Blower motor speed decrease timer value decrease and enter timer mode Middle Speed Blower motor speed increase timer value increase and cumulative timer reset High Speed Blower motor speed increase timer value increase and cumulative timer reset 13 Troubleshooting 1 If the range hood or halogen light does not operate after installation 2 The range hood vibrates when the blower is on 3 The blower or fan seems weak 4 The lights work but the blower is not spinning at all is stuck or is rattling 5 The hood is not venting out properly 6 Purpose of t
15. od should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable A U L or C S A listed strain relief must be provided at each end of the power supply cable Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply cable at the range hood and at the junction box Copies of the standards listed may be obtained CSA International from 8501 East Pleasant Valley Road Cleve National Fire Protection Association Battery land Ohio 44131 5575 march Park Quincy Massachusetts 02269 NOTE To avoid damage to your hood prevent debris from entering the vent opening 1 Carefully remove the white plastic protective coat from the chimney covers and range hood 2 Determine and mark the center line on the ceiling where the range hood will be installed Make sure there is proper clearance within the ceiling or wall for exhaust vent 3 Due to the weight and size of this unit please make sure that the support system or framework being used is stable and secure in the wall 4 Put a thick protective covering over counter top cook top or range to protect from damage or dirt Remove any ha
16. r Lights up when lights turned on Delay Digital Timer Indicator Indicates the length of time left for delay off function speed Indicator Shows current blower motor speed 1 3 Power Indicator Lights up when blower motor is running 11 Range Hood Operations Controls Control Panel Layout and Buttons Configurations for models Moon amp Viena Power amp Delay on off High speed on off Lamp on off Middle speed on off Time Setting on off Low speed on off Power off delay timer indicator Power indicator Light power indicator Speed indicator Delay digital timer indicator Button functions Power amp Delay Power ON OFF the range hood and activate power off delay timer Lamp Turns ON OFF and dim halogen lights Time Setting Time Setting ON OFF control the range hoods working time Low Speed Blower motor speed decrease timer value decrease and enter timer mode Middle Speed Blower motor speed increase timer value increase and cumulative timer reset High Speed Blower motor speed increase timer value increase and cumulative timer reset Power Off Delay Timer Indicator Lights up when auto shutdown delay timer function is on Light Power Indicator Lights up when lights turned on Delay Digital Timer Indicates the length of time left for delay off function Speed Indicator Shows current blower motor speed 1 3 Power Indicator Lights up when blower motor Is running 12 Range Hood Operations Co
17. rcoal filters Who is covered This warranty is extended to the original purchaser for products purchased for ordinary home use This Warranty Will Be Voided When Product damaged through negligence improper installation accident abuse misuse natural disaster insufficient or excessive electrical supply abnormal mechanical or environmental conditions or any unau thorized disassembly repair modification or failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connection with equipment of other manufacturers Repaired or modified by anyone other than your local reseller s authorized agents This limited warranty also does not apply to any product on which the original identification information has been altered obliterated or removed has not been handled or packaged correctly or has been sold as second hand What is Not Covered Consumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Damage of product caused by accident fire floods or act of God The manufacturer and or distributor reseller is not liable for and does not cover under warranty any loss of properties or any costs associated with removin
18. roper instruc tions Disassembly is recommended to be performed by qualified personnel only Read and under stand all instructions and warnings in this manual before proceeding Specifications Specifications Body Stainless Steel Tempered Glass Power Rating General Input Power Motor Input Power Levels Of Speed Contra Air Pressure Noise Level dB sone Fan Type Control Type Dual Electronic Control Panels with LCD Display Filtration Type Aluminum Filter with Reversible Handle Illumination 4 X 20 W hallogen Lights Venting Size Top 6 inches Round Subject to change without notice please contact your local reseller for details 15 Specifications For Wall PRO Venice Body Stainless Steel Tempered Glass Power Rating General Input Power Motor Input Power Motor Revolution 600 RPM 410 to 1800 RPM 410 Levels Of Speed Contra Air Pressure Noise Level dB sone Fan Type Control Type flumination Venting Size Top 10 inches Round For optimal operation clean range hood and all baffle spacer filter grease tunnel oil container regularly Regular care will help preserve the appearance of the range hood Cleaning Exterior surfaces e Clean periodically with hot soapy water and clean cotton cloth Do not use corrosive or abrasive detergent e g Comet Power Scruv EZ Off oven cleaner or steel wool scoring pads which will scratch and damage the stainless steel surface For heavier soil use
19. s being called You can fight the fire with your back to an exit To reduce the risk of injury to persons in the event of a gas leaks e Extinguish any open flame e DO NOT turn on the range hood fan or any type of ventilator e DO NOT turn on the lights or any type of appliance e Open all doors and windows to disperse the gas If you still smell gas call the gas company and fire depart ment or dial your local emergency service immediately Your safety and the safety of others is very important We have provided many important safety mes sages in this manual and on your appliance Always read and obey all safety messages All safety mes sages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed A WARNING This is the safety alert symbol This symbol alerts you to potential hazards that can hurt you and others All safety messages will follow the safety alert symbol and the word WARNING The manufacturer and or distributor reseller declines all responsibility in the event of failure to ob serve the instructions given here for installation maintenance and suitable use of the product The manufacturer and or distributor reseller further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance The manufacturer and or distributor reseller will not be
20. tainer and grease laden surfaces clean Grease should not be allowed to accumulate on fan baffle spaces filter grease tunnel and oil container e Always turn range hood ON when cooking at high heat or when cooking flaming foods e Use high settings on cooking range only when necessary e Never leave surface units unattended at high settings Boil over cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings e Clean ventilating fan frequently e Always use appropriate cookware and utensils size e Always use cookware appropriate for the size of the surface element Important Safety Notice Read all Instructions before installing and operating this appliance To reduce the risk of injury to persons in the event of a stove top grease fire e SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn OFF the burner BE CAREFUL TO PREVENT BURNS NEVER PICK UP A FLAMING PAN you may be burned KEEP FLAM MABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES If the flames DO NOT go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately e DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a Class A B C extinguisher and you already know how to operate it The fire is small and contained in the area where it is started The fire department i
21. uipment manufacturer s guideline and safety standards such as those pub lished by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e Before servicing or cleaning unit switch power OFF at service panel and lock service panel to prevent power from being switched ON accidentally e Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages e Ducted fans MUST always be vented to the outdoors e Use only metal ductwork and this unit MUST be grounded e Sufficient air is needed for proper combustion and exhausting of gases through the duct to prevent back draft Ing e When cutting or drilling into wall or ceiling be careful not to damage electrical wiring or other hid den utilities e All electrical wiring must be properly installed insulated and grounded e Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease fire e Check all joints on duct work to insure proper connection and all joints should be properly taped e Use this unit only in the manner intended by the manufacturer If you have questions contact the vendor To reduce the risk of a stove top grease fire e Keep all fan baffle spaces filter grease tunnel oil con
22. zardous objects around the area when installing 5 Mark the locations of the support mounting bracket holes vent cutout if used and power supply cable cutout on the ceiling Use drill and saber saw or keyhole saw to cut openings for power supply cable and vent see Venting requirements and Electrical requirements 6 If venting to the outside installs vent system see Venting Methods Use caulking to seal exterior wall or roof openings 7 Disconnect main electrical supply prepare and run electrical wiring through ceiling or wall 8 Leave approximately 12 of electrical cord hanging from the ceiling Do not restore power until wiring is completed 9 Disconnect power cord remove the aluminum filter by pressing on the latch gently pull the alumi num filter toward the direction of dashed arrow as shown in Figure 1 10 Remove the grease cup by sliding it sideway see Figure 2 for location of the grease cup 11 Set aside the aluminum filters and grease cup until the range hood is properly installed A WARNING Ed Severe Injury Rotating fan can cause severe injury Stay clear of fan when motor is running Grease Cup Installation 1 Position the range hood on the center of cooking stove wall For best results the mounting height of the range hood should be 65 75cm 25 30 above the top of the range Mark the position of the holes which need to be drilled in order to mount the range hood 2 According to

Download Pdf Manuals

image

Related Search

Related Contents

VT100 Terminal Emulator for Datapanels User`s Manual, GFK-1698  Intel D915PLWDL  Lucent Technologies Digital Wireless System Transtalk 9000 User's Manual  Bibliothèque globale "Sample Library for Instructions"  モータドライバ直流/位置比例変換器 RN748 取扱説明書 注意 警告  MANUAL DEL OPERADOR  信州水環境マップ 2014 P. 2  EVGA GTX 580 Backplate  DSC-W320  Installation Instructions  