1. PLEASE NOTE THERE IS AN INLET AREA ON THE UNDERSIDE OF THE PRODUCT WHICH WILL REQUIRE CLEANING Recycling For electrical products sold within the European Community At the end of the electrical products useful life it should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice in your country After Sales Service Your product is guaranteed for three years from the date of purchase Within this period we undertake to repair or exchange this product free of charge Subject to availability within the guarantee period provided it has been operated in accordance with these instructions Your rights under this guarantee are additional to your statutory rights which in turn are not affected by this guarantee Should you require after sales information or assistance with this product please go to www dimplex co uk where you will find our self help guide by clicking on After Sales or ring our helpdesk on 0845 600 5444 UK or 01 842 4833 R O I Spare parts are also available on the website www dimplex co uk Please retain your receipt as proof of purchase EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC The product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 Dimplex UK L
2. NEUTRAL BROWN LIVE As the colours of the wires in the mains lead may not correspond with the coloured markings in your plug proceed as follows Connect the BROWN wire to the terminal marked L or coloured RED Connect the BLUE wire to the terminal marked N or coloured BLACK Note L or N wire must not be connected to the EARTH terminal marked E or or coloured GREEN or GREEN AND YELLOW If in doubt consult your electrician Important Operating Information ACCUMULATION OF FLUFF AND DUST IN THE HEATER MAY CAUSE THE ELEMENT TO OVERHEAT AND CUT OUT THEREFORE IT IS IMPORTANT THAT THE HEATER IS CLEANED REGULARLY PARTICULARLY IF THE PRODUCT IS USED OR STORED IN AREAS WHERE HIGH LEVELS OF DUST AND OR FLUFF ARE PRESENT I E BEDROOMS DRESSING ROOMS see section of instructions titled cleaning for details on how to maintain optimum performance of your heater Using the heater The mains neon see Fig 1 will light up to show that the heater is connected to the mains supply Heat control see Fig 2 The heat control positions are as follows Oo Off Cool Blow Pa ay Half heat output Il Full heat output Fig 2 a Thermostat control see Fig 3 The heat output is controlled by the thermostat according to the room temperature Turn the knob to maximum setting initially When the room is warm enough reduce the setting slowly until the heater just clicks off
3. The heater will now cycle on and off to maintain your selected room temperature s ville 1 aP s A g O TTT N Fig 3 NOTE If the heater does not come on when the thermostat is set to a low number this is normally because the room is warmer than the thermostat setting and is not a fault When the heat control is set to SS for Cool Blow set the thermostat control to max position Position H will turn the heater on and off to maintain a temperature of approximately 5 C to help protect against frosty conditions Safety Overheat Protection For your safety this appliance is fitted with a thermal cut out In the event that the product overheats the cut out switches the heater off automatically To bring the heater back into operation remove the cause of the overheating then unplug or turn off the electrical supply to the heater for a few minutes When the heater has cooled sufficiently re connect and switch on the heater Cleaning ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE HEATER Do not use detergents abrasive cleaning powder or polish of any kind on this heater Wipe with a dry cloth to remove dust and a damp cloth not wet to clean off stains Be careful not to allow moisture into the heater Ensure that dust or fluff does not accumulate inside the heater as this could lead to overheating of the element Use a vacuum cleaner to remove any fluff which does accumulate
4. a X lt Dimplex Installation and Operating Instructions DXDAI2 Flat Fan Heater Model s Specification DXDAI2 2 0kw Switch Thermostat amp Neon 08 35194 3 Issue 3 handle thermostat knob see Fig 3 heat control knob see Fig 2 IMPORTANT THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE IMPORTANT SAFETY ADVICE DO NOT use the heater on deep pile carpets or the long hair type of rugs or less than 750mm 30 away from any overhanging surface Keep combustible materials such as drapes and other furnishings clear from the front sides and rear of the heater Do not use heater to dry your laundry DO NOT use the heater in the immediate surroundings of a bath a shower or a swimming pool DO NOT place the heater directly below a fixed socket outlet WARNING In order to avoid overheating do not cover the heater The socket outlet must be accessible at all times to enable the mains plug to be disconnected as quickly as possible DO NOT COVER or obstruct in any way the air inlet slots in the top and bottom of the heater or the air outlet slots at the front of the heater DO NOT operate the heater with the mains lead overhanging the front outlet grille The heater should always be used on a flat stable surface This appliance is not intended for use by children or other persons without assistance or supervision if their physical sensory or mental capabilities prevent them fr
5. om using it safely Children should be supervised to ensure that they do not play with the appliance Warning In order to avoid a hazard due to inadvertent resetting of the thermal cutout this appliance must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility THE HEATER CARRIES A WARNING SYMBOL INDICATING THAT IT MUST NOT BE COVERED The instruction leaflet belongs to the appliance and must be kept in a safe place If changing owners the leaflet must be surrendered to the new owner IMPORTANT If the mains lead of this appliance is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard Electrical connection This heater must be used on an supply only and the voltage marked on the heater must correspond to the supply voltage This heater is fitted with a rewirable plug incorporating a 13 amp fuse In the event of replacing the fuse in the plug supplied a 13 amp fuse approved by ASTA to BS 1362 must be used If any other type of plug is used a 15 amp fuse must be fitted in the plug the adaptor or at the distribution board IMPORTANT If the plug is not suitable for your socket the 13 amp plug should be removed Before wiring the appropriate plug please note that the wires in this mains lead are coloured in accordance with the following code BLUE
6. td Millbrook House Grange Drive Hedge End Southampton Hampshire SO30 2DF c Dimplex UK Limited www dimplex co uk Republic of Ireland Tel 01 8424833 All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Dimplex UK Limited
Download Pdf Manuals
Related Search
Related Contents
Case Logic XNSLR-6 GeoVision GV-Data Capture Troubleshooting warnings - The Singing Machine Aparelhos de fusão MC 20 / MC 21 para sacos de película PLA Series User's Guide Motorola XOOM User's Manual 取扱説明書 詳細版 User Guide - Honeywell OVEN USER`S MANUAL neoVI PLASMA Help 12May13 - Intrepid Control Systems Copyright © All rights reserved.