Tri-Electronics GXL-18 Gold Tester User Manual

image

Contents

1. the Rotary Cap counter clockwise a click at a time until a drop of gel appears on the tip Wipe this first drop of gel on the towel and turn usually one or two clicks until a small gel sample appears Immediately touch the sensor to pre selected cleaned point on the test object DO NOT LET GEL OR SENSOR NOZZLE TOUCH THE ALLIGATOR CLIP 6 Press one of the following buttons Y Yellow W White R Red or G Green depending on the color of the gold See Diagram 1 4 for button location 7 Maintain the sensor in the vertical position for approximately 5 seconds while the instruments calibrates the gold value SERVICE If there are any problems regarding the GXL 18 please contact us TRI Electronics Inc 9570 Ridgehaven Court SUITE A San Diego CA 92123 Attn Service Dept Phone 858 571 4881 FAX 858 571 5404 E mail support trielectronics com
2. GXL 18 Owner s Manual INTRODUCTION The G XL 18 Gold Tester is a digital computerized portative instrument developed for efficient and quick determination of gold karat values from 6k to 18k It can also distinguish between gold plated and solid gold items There are four types of gold yellow white red pink and green THE G X 16 DISPLAY UNIT 1 2 3 4 5y _ oo pa Diagram 1 Display Unit Electronic unit Alpha numeric Display Window Low Battery Indicators Gold Selection Buttons Sensor Outlet Optional Converter Connection ON OFF Power Switch S e a Note When using the optional converter the power switch must be in the OFF position THE MECHANICAL SENSOR The Mechanical Sensor for the G XL 18 Gold Tester consists of the sensor body and a polyethylene tube with gel The polyethylene tube must be placed inside of the sensor s body before beginning a test Diagram 2 shows each part of the mechanical sensor Worle ra Mose lane Wire Cover Nase Cone Cap Flug Outlet Sensor Bod otationary Cap rigid connected Rotary Cap together Diagram 2 Sensor Diagram 3 shows the cross section of the polyethylene tube 1 Tube Cap 4 Feed Screw 7 Feed Screw 2 Tube Nozzle 5 Piston Engagement 3 Tube Body 6 Bottom Plug Diagram 3 Polyethylene Tube When using the Sensor be sure that The sensor nozzle is clean Use the plastic cleaner Supplied to clean the o
3. pening When testing dispense THEN dispose of the drop of gel following each test For best result use every other gel drop for testing LOADING CHANGING THE POLYETHYLENE GEL TUBE Take off the nozzle cap Diagram 2 Remove the Stationary Cap by turning the light colored barrel Diagram 2 counter clockwise Please remember that the Stationary Cap and the Rotary Cap are undetachable Diagram 2 3 Insert the Feed Screw Engagement Diagram 3 7 into the appropriate slot of the Rotary Cap Be sure that the Feed Screw is fully engaged 4 Take off tube Cap Diagram 3 1 5 Insert the polyethylene gel tube which is fully lodged in the Stationary Rotary Cap into the sensor and turn the bright colored barrel Diagram 2 clockwise until fully seated Do not turn the dark colored top barrel Diagram 2 7 clockwise or it will damage the mechanism 6 Turn the Rotary Cap counter clockwise several times until the first drop of gel appears at the sensor nozzle OPERATION PROCEDURE 1 Load the polyethylene gel tube 2 Connect the black wire to the sensor s plug outlet the black and red wire connector to the display unit and the red wire to the testing plate 3 Turn the unit ON See Diagram 1 7 for switch The unit should display display G XL 18 READY TO TEST 4 Select a testing point on the object close to BUT NOT TOUCHING the alligator clip 5 Holding the sensor in the vertical position with the nozzle down twist

Download Pdf Manuals

image

Related Search

Related Contents

Kompakt HR Solo 12 und 22 Solo 28 Kombi 28/24 Kombi 36/30  Matrix Tauchcomputer  1 Expte. Gub. 35/12 INSTRUCCIÓN 10/12 UTILIZACIÓN DEL  新たな「知」の保護管理のあり方に関する調査研究 (PDF:5078KB)  BBG-1090-ENC-H264-IP User Manual  T'nB MUSIC TREND Ladies Night  Complément au Manuel d`Utilisation  XLT Electric Oven & AVI Hood Parts & Service Manual  RC-7700  

Copyright © All rights reserved.
Failed to retrieve file