1. 9 3 Save Click to make the new factor to instead of the existed one Cancel Click to cancel this test 57 Chapter 10 Quality Control Test 1 QC Test Procedures Distilled Water Test Blank Test QC Materiel Test Next QC Materiel Test l The Rinsing process is not mandatory process in order to avoid crossed pollution rinse with distilled water after the completion of each test 2 When setting the sample blank as the blank mode of test parameter please test the QC blank before each QC Materiel test Figure 10 1 E g test ALT with sample blank as follows Step 1 Turn on the instrument enter the main interface Click Test to the Select Animal interface select a animal and click OK thenenterthe Select Test In Select Test interface click ALT and OK or double click ALT to enter Test interface In order to confirm test parameter of ALT is correct click Edit to enter Test Parameter Setting Jinterface then click Calibration Parameter to examine or change Step 2 Selected ALT system will adjust the Lamp and Temperature automatically While the light source is steady and the temperature is correct Operation Notice shows Please aspirate distilled water 58 Step 3 Press ASP key under the pipette or on the keyboard to aspirate distilled water wait for testing Operation Notice shows Please aspirate the sample blank Step 4 Press AS
2. Master Name Animal Sex ee Phone Animal Age i Y lo 1M Add Test Animal Mame Tested Date 21 Figure 11 1 61 1 Sample Records List display what you query select one or more records to print browse or delete 2 Test Records List display the selected test records inf Sample Records List select one or more to delete Query Click to display the dialog Input Test Records Conditions Figure 11 2 and input the query terms then click OK to query the records Print Click to print the selected records Preview Click to preview the effect of printing Add Sample Click to display Add Sample Records interface on the following figure then add a sample record Delete Sample Select a sample in the Sample Records List interface to delete it Attention Delete all relevant records if delete the sample Master Name User can input or amend the master name here Phone User can input or amend the master s phone number here Animal Name User can input or amend the animal name here Animal Sex User can input or amend the animal sex here Animal Age User can input or amend the animal age here Test Date Display the test date here and the date can t be amended Edit Click it then user can edit the sample info Save Select a sample in thef Sample Records List Jinterface and input the sample name sex etc then click Save to save Add Test Click to disp
3. automatically assigned to this Obtain an IP address via DHCP computer If your network Specify an IP address does not automatically assign 192 168 0 254 IP address ask your network E dados o administrator for an address Subnet Mask 255 255 255 0 and then type it in the sapce provided Default Gateway 192 165 O 1 Figure 5 6 Because of the differences of network environment this manual can not specifically introduce the IP setting process If user can not understand how to operator you can ask the local network administrator If the IP Setting is finished data can be uploaded from device to personal computer through data transmission Hint User can only use the function when the network is selected 29 4 Data Maintenance Click Data Maintenance enter the interface as figure 5 7 user can select the operation from Data Backup Data Import Delete Data or Data transmission Data Maintenance Coton Data Backup Data Import O Delete Data O Data Transmission Figure 5 7 Data Backup Select Data Backup and click Start to backup the data Data Import Select Data Import and click Start to import the data Delete Data Select Delete Data and click Start to delete the data Data Transmission Select Data Transmission Jand click Start to transmission the data 4 1 Data Backup Insert SD or Flash Card then select Data Backup Jin figure 5 7 and click St
4. will display after distilled water test gt 4 Press ASP to aspirate sample blank See the operation manual of the reagent and wait for the Sample blank test The system will alarm Factor or calibration information is invalid if there is no valid factor after the blank test or the parameters has been changed after done calibration last time See figure 8 2 This notice means the user must input the correct factor or calibrate before sample test The system will notice Please aspirate Sample after valid factor occurred Yet Biochemical Analyzer Factor or calibration information may be invalid Please input the factor or calbrate again Figure 9 2 gt 5 Click Calib and the system notice Please aspirate Standard Blank Press ASP to aspirate the Standard Blank liquid according to the first concentration point See the operation manual of reagent Click Rinse Jor press Rinse Jon the keyboard to aspirate distilled water to rinse after every test to avoid crossed pollution and keep the instrument clean Click Rinse or Press Rinse again to stop rinsing The system will notice Please aspirate standard liquid Test 1 after test Press ASP to aspirate certain concentration standard liquid The instrument will repeat the test on this standard point Repeat time21 The system will display following interface Figure 9 3 after all the standard test is finished 56 Calibration Result
5. 1 21 Yet Biochemical Analyzer Distilled water test unpassed Retry Linpassed wavelength Retry Cancel 2 Figure 4 7 Retry Press it to begin self test and distilled water test again Cancel Press it to enter main interface window as figure 4 9 Hint gt If self test is failed user can retest distilled water several times Self test failed may be attributed to the failure of optical or flow system Users can retest after rinsing the pipe If the problem cannot be resolved you can contact the designated maintenance points gt User could do repetitious test when distilled water test is unqualified It could be caused by pollution of distilled water reagent or even the flow channel User could aspirate ethanol to rinse If it is still unqualified after repetitious rinse the device maybe in malfunction Please contact with the maintain personnel gt Press Rinse for repetitious rinse to renormalize when it appears abnormal after device be in long time storage or transportation System would display serial communication failure if system inner communication is in malfunction Figure 4 8 Please contact with distributor or our company if user meets this problem Serial communication failure ARE Figure 4 8 22 3 Main interface window System enter main interface after distilled water testing Figure 4 9 Vet Biochemical Analyzer Pii tT To apas m TS z TEST
6. In Sample records interface browsing by sample select the records in Sample Records List Jinterface for operating Sample records will be display in the edit textbox below Sample Records List then input the information and click Save to finish editing the sample records Select the records in the Sample Records List interface for operating Click Delete Print or Preview to delete print or preview Click Add new sample show as the following figure Input the information and click OK to add a new sample 64 Add new sample Sample SN Species Master Name Sex Male Phone Age lo Y lo M Animal Name Tested Date 2008 4 8 OK Cancel Figure 11 3 6 Add edit or delete test records Browsing by the sample in Sample Records interface Select the records on the Sample Records List for operating The Test Records List will display all the records of this sample Select the test records in the Test Records List interface Click Delete Test to delete the test records Click Edit Test in Edit test result interface See the following figure Input the information then Click OK to finish editing Or click Cancel to quit editing Edit test record Sample SN Test Name ALT Ref Upper Limit 523 0 Concentration ps5 Ref Lower Lirnit 15 3 Absorbency 0 0 14 Figure 10 5 65 Click Add Test to show the following dialog then input the
7. the voltage between the neutral line and earth line lt dSV 2 Installation 2 1 Installation 1 Take the instrument out from the package and place it on a stable worktable 2 Check its appearance and start to install Check the power supply at first and insert one terminal of itself three core wire to the socket of the instrument and plug the other terminal to the electrical outlet Put out the mouse and connect it to the USB socket Prepare a container and put the liquid waste pipe in the container Keep the package case and packed parts well 2 2 Adjustment of display A 7 TFT LCD display offered to this instrument In order to obtain a best visual angle the user can adjust the active display freely Operations about adjusting the display as following figure Figure 2 1 2 3 Install the print paper as figure below 1 lever 2 the cover of printer 3 paper 4 platen knob Figure 2 2 a Press down OPEN and open the cover of printer b Got rid of the package of the print paper and place it in the flute Pay attention to the positive and negative direction of the print paper for thermal printer c Insert the print paper to the inlet of the printer put up the lever roll the platen knob till the paper walk out 10 cm and then push down the lever d Lead the paper through the cover of printer close the cover and finish the installation 2 4 Check flow channel Lift the removable cover check the position a
8. Blank Method Please input the correct factor or to calibrate in this occasion 41 4 ABS Parameters ABS is used to inspect the performance of the instrument according to ABS graph during the test There is no calculation result in ABS Test select ABS in the interface as figure 7 1 to display following interface as figure 7 4 Figure 7 4 Parameter Setting of ABS Num of Read Points The total points of reading the ABS Read Time s The total time seconds of reading the ABS See part 2 of present chapter for others 42 5 Calibration Parameters Click Calib Para in the Parameter Setting interface then display as figure 7 5 Calibration Parameter Test Name ALT Calibration Method Standard Concentration Repeat Times 1 oF 7 5 Calibration Parameters Calibration Method There are linear and non linear selectable There is only one standard concentration point in linear method There are not less than 2 and not more than 10 standard concentration points in non linear method Repeat Times Repeat the test of standard concentration points and calculate calibration factor according to the average to improve the precision The repeat times should not less than 1 and not more than 3 Standard Concentration It is to list the concentration of existed standard concentration points Add Click to add a standard concentration point Delete Click to delete a standard concentration point fro
9. End point Fixed time Kinetics Two wavelength Multi standard Sample blank m Urine blood serum and body fluid can be tested m Reagent opened both of oversea and home reagents available m Pipeline drains out automatically after testing protecting the tubes and flow cell m 7 LCD display reaction curve shown on the test interface abnormal phenomena can be found in time m Great capacity for storage of user data and abundant programs m Perfect functions for quality control quality control range 31 days m Port for Ethernet available data transmissible m External mouse keyboard and printer available based on USB m Adopt flow cell with volume 32 ul E Built in Thermal Printer m The format of printing report supports the print function according to the project animal and case history m Automatic sensing of flow cell cuvette insertion m The intrinsic species of animals are 8 types and user can customize 8 others 3 Range applicable This analyzer is applicable to veterinary clinics pet hospitals or animal research institutions etc 4 Technical specifications Photometric range 9 000 3 000 Abs Optics system 340 670nm 7 filters built in 340 405 505 546 578 620 670 nm precision for 340 nm 2 nm width of half wave 10nm precision for other wavelength 1 nm width of half wave 8nm User can add a wavelength if necessary Room temperature 25 C 30 C 37 C 0 1 C Linear of absorbency 29 999 Port
10. Move focus to previous control which can receive it function is equal to Shift Tab key on the keyboard Move focus to next control which can receive it function is equal to Tab key on the keyboard lt Move focus to previous control which can receive it function is equal to Shift Tab key on the keyboard Move focus to next control which can receive it function is equal to Tab key on the keyboard Enter Equal to pressing the mouse or Space key 2 9 Option Button Colorimetry Method Flowcel Cuvette Selected status for flow cell without focus unselected status for cuvette without focus Colorimetry Method Floweell Selected status for flow cell with focus unselected status for cuvette without focus When control holds focus the function of direction key and enter key as follows 1 Move focus to previous control which can receive it function is equal to Shift Tab key on the keyboard Move focus to next control which can receive it function is equal to Tab key on the keyboard lt lt Function is equal to the on the keyboard Function is equal to the on the keyboard Enter Function is equal to pressing mouse or Space key on the keyboard 2 10 Combo Box only can be chosen No blank x Y1 Without focus currently value of the selection is No blank Forbidden status lo blank Status with focus value of the curre
11. To make sure the instrument in a good state routing maintenance is strongly required Although the BS600V routing maintenance isvery easy you must be patient and careful 1 Clean the instrument Clean fancies of the instrument with neutral cleanser or a piece of wet cloth keep the environment of the instrument clean 2 Clean the flow cell a Clean the exterior of the flow cell If the exterior of the flow cell is dirty you can clean it with a piece of soft cloth moistened by absolute alcohol b Clean the inner of the flow cell Place the container with distilled water under the pipette press Rinse key to start rinsing again to stop rinsing Generally 30 seconds is needed You can also use quartz glass cleanser press Rinse key first press Rinse key again to stop allow cleanser to stay in flow cell for several minutes at last rinse it with distilled water for 1 minute If the flow cell is still not clean please rinse it once again c Make sure clean the flow cell before turn off the instrument 74 3 Instrument maintenances 1 Replace fuse 1 Insert a tweezer into the groove and prize the fuse box out 2 Take the fuses out and repalce it As figure 16 1 Groove ay Two fuses Figure 16 1 Fuse type 250V 2A 5 20 O Notice The fuse of above type allowed only make sure power wire is disconnected when replace the fuse Operation with electricity is forbidden 2 Change pipe
12. down and be free of rains or snows Transport and Storage Environment Temperature 0 C 40 C Humidity lt 80 Product Label and Nameplate 78
13. for SD card great capacity available through SD card Port for RS232 Ethernet and SD card 4 USB ports Ants Built in Thermal printer and supports laser printer and ink paint printer available based on PCL print language and USB port High speed embedded processor Weigh Temperature 10 C 30 C relative humidity lt 70 atmosphere pressure 86KPa 106KPa Working environments Temperature for 20 C 55 C storage and transportation Chapter 2 Installation 1 Before installing Unpack the package and check the packed parts and documents prepare to install if all is right If any question please contact with the service department of our company At the meantime please write the guarantee for service and mail it back to our company which is convenient to track and offer you available service lt p Notice Working temperature 10 C 30 C Relative humidity 70 To make sure the instrument work normally please avoid placing the instrument in following environments Humidity corrosive gas dusty strong electromagnetic interference Crowd and non aeration Non steady worktable Do not place the instrument near the centrifugal Requirement for power supply a AC100 240V 50 60HZz b The instrument cannot use the same power supply socket with some high power equipments including centrifugal refrigerator and oven etc c The power supply should earth well and connect the power supply with three cores wire
14. information and click OK to add a new test and return Or click Cancel to quit and return Add new test record r Figure10 6 66 Chapter 12 Calibration Records 1 Summary The analyzer can be calibrated with single point or multi points mode 2 Query and print the calibration records In the main window click System then click Calibration records to show the following figure Test Marre tie Calk Method F Facto i S92 Figure 12 1 Test Name Select test then the system will look for the calibration records of this test and display the information with two modes data and figure If the calibration records of the test has existed the Print Print Preview button can be clicked Num of Points Number of the standard concentration points Calib Method Calibration method linear or non linear Date Calibration time Factor Calibration factor if non linear there is no factor 67 Preview Click to preview the effect of printing Print Click to print calibration records Calibration Data Show the calibration data of the selected test 68 Chapter 13 Quality Control 1 Summary 1 BS600V biochemical analyzer has a powerful quality control function it is so convenient to operate which makes the QC in lab very easy 2 Three QC materials can meet all test projects 3 Calculate AVG SD and CV
15. of the QC in a certain time selected automatically 2 Query and print QC records Click SYSTEM in main window select QC records Jin pop up window then you can see the following interface figure 13 1 Test Name a T QC Material Joc Materiali Date From 2007 10 4 fo007 11 4 e Show cur Figure 13 1 Test Name Select the test need to query QC material Select the QC material need to query Date From Specify the start date need to query To Specify the end date need to query Query Click to get the results Show Curve Click this item to show QC curve of the queried result along with the AVG SD and CV calculated automatically 11 04 2007 11 03 2007 11 02 2007 11 01 2007 10 31 2007 10 20 2007 10 29 2007 10 28 2007 10 27 2007 10 26 2007 10 25 2007 10 24 2007 10 23 2007 Print Preview Click this item to preview the effect of the QC records Print Click to print the QC records 69 Chapter 14 Turn Off 1 Click EXIT in the main window you can see the following dialog Vet Biochemical Analyzer Sure to power off Figure 14 1 YES Click to enter power off process NO Click to return the main window 2 When click YES you can see following window Please rinse Figure 14 2 Click ASP OR Rinse to aspirate the distilled water then the instrument start to rinse Whe
16. 611 2 1 EN2 September 2009 Contents the semi automatic biochemical analyzer 3 4 Chapter 4 Boot strap 1 Process of boot strap 2 Interface of boot strap Il Welcome using the semi automatic biochemical analyzer BS600V Dear Users Welcome using the semi automatic biochemical analyzer BS600V It is our honor for the semi automatic biochemical analyzer In order to know our product well we offer you this operational manual which includes the features appearance and dimension using methods usage instructions maintenance packing storage and transportation etc We try our best to edit the operational manual to be easily understood so as to make sure you can know the instrument better Please read the manual carefully before operation and it is great helpful for you to operate the instrument correctly We try our best to offer correct all sided and reliable information in the manual and avoid the man made mistakes Please forgive us for some little mistakes unchecked out or some carelessness uncontrollable We will update hardware and software at any time so as to promote the capability and reliability Please forgive us it may be result in the manual cannot be match to changes in time Please contact us at any time if you find any mistake or carelessness in the annual during your operation Before operation please do as follows at first 1 Make sure the actual fittings of the instrument consistent to
17. Data Data Transmission m Status Walt Total 0 Figure 5 12 32 Stop Click it to pop up the dialog box in figure 5 13 Vet Biochemical Analyzer sure to stop transmission the data Figure 5 13 Yes Click it to stop data transmission No Click it to return data transmission status Hint Steps of data transmission from device to computer are as follows Yy According to the device setting and actual usage situation User can link up the device and computer with serial line or net line gt Set data transmission mode to be a corresponding mode in the System Setting interface gt Operate it reference to the section data transmission and then enter the data transmission status gt Run BCA Data Center software in personal computer user can operate the software reference to help document and obtain data from the device 33 Chapter 6 Animal Setting User must select the type of test object before testing User can select it in the Select Animal interface If you do not see the choice as to the types you can increase the animals by importing new animal names and adding new animals Photo 1 Select Animal As shown in Figure 4 10 in the main interface click Test button enterthe Select Animal interface first as shown in Figure 6 1 User Define OR Cancel Figure 6 1 Select Animal User define If the intrinsic species of animals doesn t includ
18. P key to aspirate the prepared sample blank See the reagent manual for preparing method wait for testing The system will alarm Factor or calibration information is invalid if there is no valid factor after the blank test or the parameters has been changed after done calibration last time See figure 9 2 This notice means the user must input the correct factor or calibrate before sample test The system will notice Please aspirate Sample after valid factor occurred Yet Biochemical Analyzer Factor or calibration information may be invalid Please input the factor or calibrate again Figure 10 2 Step 5 Click QC button show the following dialog to remind operator to select QC Materiel Select OC Material 3 Number Three Batch No Mean Value p JO Min Value poco Figure 10 3 Number One Test the QC Materiel 1 if selected Number Two Test the QC Materiel 2 if selected Number Three Test the QC Materiel 3 if selected OK Click to finish selecting then return to the Test interface and begin testing Cancel Click to quit selecting then return to the Test interface and quit testing Step 6 Selected QC Materiel gt 0 Operation Notice Jshows Please aspirate QC Blank 59 inthe Test interface press ASP to aspirate the first QC Materiel Blank See the reagent manual for preparing method wait for testing To avoid crossed pollution please click Rinse or press
19. RECORDS SYSTEM _ ee Figure 4 9 main interface TEST Press it and enter Select Test interface RECORDS Press it and enter Sample Records interface SYSTEM Press it to show a pop up dialog box User could select the QC Records Calibration Records System setting interfaces EXIT Press it to turn off the device 23 Chapter 5 System setting 1 System Setting Press System in main interface then select System Setting to enter the setting interface User could set Hospital Name System Date or any other parameters Except Hospital Name all other items were sat already before left factory Hospital Name i Instrument SM JA Lamp Idle Time s 250 i Set Printer Insttument Maintenance Data Maintenance Figure 5 1 o General parameters setting area Hospital Name Input hospital name here Instrument SN It is as the same as the nameplate of the instrument which can t be amended for after service Lamp Idle Time In order to protect lamp set a period time after testing to turn off the lamp Printer There is a built in thermal printer in instrument Also it supports external printer based on PCL language such as HP LaserJet 1150 and HP LaserJet 1160 Print In Series Only available with external printer please refer to the print sample record in the part of sample record 24 Colorimetry Method Flow cell or cuvette both availab
20. Rinse key to aspirate distilled water for rinsing click or press it again to finish rinsing While QC Materiel Blank is tested system shows Please aspirate QC Materiel then press ASP to aspirate QC Materiel for testing Test next QC Materiel if last test is finished If all QC Materiel is tested system will show the following dialog click OK Jto finish the test Yet Biochemical Analyzer OC Finished Figure 10 4 OK Click to finish the test and return to the Test interface 60 Chapter 11 Sample Records Summary The analyzer can query the records by fuzzy or combination terms It facilitates management of patient records in hospital by providing powerful capability of test records inquiry function and the report of the patients print functions 2 Browse sample records Click Records Jin main interface or Click Today Records Jin Test interface to show Sample Records interface System could inquire sample test records today automatically when the window is opened seeing the following figure test records are displayed or printed The system displays case history in the order of dates The later records are displayed on the top The system can display the records less than 200 oF l e Sample Records a ane A eae Q ELI Query Boa Preview el ee Print al Add Sample i Delete Sample P SN Tested Date Test___ conc 200R A Jg Test records list Sample records list
21. Test Figure 8 10 Sample Test Procedures The single test procedure with template is as the same as the test with non template mode 54 Chapter 9 Calibration Test 1 Calibration Test Procedures Distilled Water Test Blank Test Calibration Test Next Calibration Test 1 The Rinsing process is not mandatory process in order to avoid crossed pollution Rinse with distilled water after the completion of each test 2 Please follow the blank test of the Standard liquid when the parameter setting is Standard Blank Test Figure 9 1 This instrument provides two calibration tests linear and non linear E g ALT calibration Test Procedures gt 1 Turn on the instrument to enter the main menu Click Test to the Select Animal interface select a animal and click OK then enter the Select Test Select ALT and click Enter or double click ALT to Test Jinterface Click Edit to the Test Parameter Setting Jinterface Please set the parameters if the parameters existed could not comply with the operation manual of the Reagent gt 2 The system will adjust the Lamp and Temperature automatically The real time temperature will be displayed on the top right corner of the interface The operation notice Please aspirate distilled water will display after the adjustment 55 gt 3 Press ASP under the pipette or on the keyboard to aspirate distilled water The operation notice Please aspirate sample blank
22. art system will backup the data to SD or Flash Card 4 2 Data Import Insert SD or Flash Card then select Data Import in figure 5 7 and click Start show the dialog box as figure 5 8 30 Yet Biochemical Analyzer Sure to Import the data Figure 5 8 Yes Click to import the data System search the data file and import the data automatically No Click to quit importing data return to the Data Maintenance interface 4 3 Delete Data Select Delete Data in figure 5 6 the interface update as figure 5 9 Data Maintenance Coton Data Backup Data Import O Data Transmission Delete the data prior to the date 2007 9 13 4 Figure 5 9 Select the date in figure 5 9 and click Yes show the dialog box as figure5 10 Yet Biochemical Analyzer Sure to delete the data Figure 5 10 31 Yes Click to delete the data System deletes the control and sample records prior to the selected date as figure 5 9 No Click to suspend the implementation of deleting data return to the Data Maintenance interface 4 4 Data Transmission Select Data Transmission in figure 5 7 the Data Maintenance interface update as figure 5 11 Data Maintenance ption Data Backup O Delete Data Figure 5 11 Click Start the Data Maintenance interface enters the data transmission status as figure 5 12 Data Maintenance Coton Data Backup Data Import O Delete
23. as the same function as the ASP key under the pipette ASP only works with the hint for aspirating by system 3 5 7 Enter The five keys are corresponding to those on the soft keyboard Normally user could use mouse and soft keyboard to finish all operation User could use them instead of mouse and soft keyboard when they can t work 4 Introduction of operation interface window The signs below only appear on the main operation interface window oF he a Display the temperature of the testing room Display as room temperature if no operation for temperature control 16 53 11 E Display the real time See the section System setting for adjusting the time Click it to control the soft keyboard of the off status English language input status It is the same as the key on the keyboard Ahe status of the lamp is ON The status of the lamp is OFF Return Press it to turn off the current window and return the previous window 5 Return is in useless status Please find cancel button for return 18 Chapter 4 Boot strap 1 Process of boot strap Turn on the power System is loading loading interface displays as figure 4 2 System is loaded welcome interface displays as figure 4 3 System automatically activates the program entering the lamp stabilization process Figure 4 4 Auto check is completed suggests Distilled water test please aspirate Fig
24. ce display as figure 8 1 If select the template mode the interface nearly accord with figure 8 1 except the button Test changed to Next Test Select the test name and click Select Test to enter the Test interface as figure 8 1 Test ALT TA 37 00 A 10 17 25 Q us Sample SN fi Stp H Aise Please aspirate distilled wa Operation prompter TEA Sped s Deog x Test Method kineb es Factor 4180 000 Inspection Area Ref Upper Limit 57 3 Ref Lower Limit 2 20 Parameters Ciprntonine Print curve Testing Result 8 1 Testing Interface 1 Parameters To display the parameters of the test selected 2 Operation Notice To display the operation being carried on and notice the next step 3 Testing Result To display the result calculated be the device 4 Inspection Area To display real time ABS graph during the test Test Click to enter the Select Test interface Para Click to review and edit the parameters selected Species select animal Stop Click to stop the test being carried on Calib Click to calibration QC Click to start QC Test 48 Rinse The function is the same as Rinse on the Keyboard Present Record Click to enter the Sample Records interface to review the test record today Print curve Click to print the current reaction curve Print Online Click to print the testing result online 2 Sample Test 2 1Test with non tem
25. cus to next control which can receive it function is equal to Tab key on the keyboard Enter Equal to pressing left key of the mouse or pressing Space key 2 Edition Bar Name ALT When hold focus there will be a flickering vertical line or the letter is selected the selected letter has blue background Otherwise it means the edition bar have no focus Name Jal 7 Edit dialog box at the forbidden state it become gray and its words cannot be input in the dialog box When control holds focus the function of direction key and enter key as follows 1 Move focus to previous control which can receive it function is equal to Shift Tab key on the keyboard 1 Move focus to next control which can receive it function is equal to Tab key on the keyboard lt Move cursor to previous letter function is equal to key on the keyboard Move cursor to next letter function is equal to gt key on the keyboard Enter Move focus to next control which can receive focus the function is equal to Tab key on the keyboard 2 8 Check Box Print In Series Unselected status without focus currently Print In Series Forbidden status M Print In Series Selected status no focus currently _ PrintIn Series Unselected status hold focus words with broken line around them mean holding focus When control holds focus the function of direction key and enter key as follows 1
26. e SN the Sample SN according with the condition may be 1 11 21 or 31 OK Click to query and display the result in Sample Record interface Cancel Click to quit querying and return to the Sample record interface The relation of all query terms is and For instance 1 as the sample ID ALT as the project name John as the name date from 1 1 2006 to 4 1 2007 if fuzzy query the result is the sample records that the test date from 1 1 2006 to 4 1 2007 sample ID 1 and name including John and tested ALT For a period of time the record of data base is increased and then the query time will be longer In addition if the query term is too fuzzy the result will be too much to display 63 Please input the more complete term when you query 4 Print sample records Select the sample records in the Sample Records window and click Print to print the selected records If selected the external printer there will be two print mode continuous or discontinuous See the section System setting for selecting and setting the printer Continuous mode is to print more records on a sheet A4 paper External printer A4 paper Simultaneity all project records of a sample will be printed on the same paper mostly On discontinuous mode different sample records can t be printed on the same paper 5 Add edit or delete sample records
27. e bar and close button 2 3 Blinking cursor We call the flickering vertical line as blinking cursor where you can input words If you click the character key on the keyboard the character will be inserted to the location where the cursor is 2 4 Control Control means the displayed information or received element of the window such as Radio Button Edit box Check Box Optional Button Combo Box List time amp date picker refer to the following section 2 6 to 2 13 is the instruction about control 2 5 Focus Focus designates the object input from keyboard When a control or window hold focus the control or window can be input from keyboard Freely move the focus in the control by the keys Tab Shift Tab Judge holding focus or not user can detail read below instructions about the controls 2 6 Radio Button OK Button without focus At the state of forbidden the words become to gray and it cannot be Button with focus the dash rim stand for this button has focus When control holds focus the function of direction key and enter key as follows 1 Move focus to previous control which can receive it function is equal to Shift Tab key on the keyboard Move focus to next control which can receive it function is equal to Tab key on the keyboard lt Move focus to previous control which can receive it function is equal to Shift Tab key on the keyboard Move fo
28. e testing animal click this button to enter the Add Animals interface for adding new animal species OK Click the button to select after clicked the picture of testing animals Cancel Click the button to suspend the operation and return to the former interface Hint Double click the pictures of some animals is equivalent to click the pictures and OK button 34 2 Add Animal Click Customize animal button in the Select Animal interface then enter the Customize animal interface show as follow Figure 6 2 Select Animal The edit box Below each picture frame display animal names if the edit box isn t blank show that there has been set up animal species on the contrary show that there is not yet provided animals Set Picture Click this button after Click a picture to pop up figure 6 3 choice dialog select the picture files Click OK to add a picture Add Animal Click to turn the edit box to be inputted then user can input new animal species name Delete Animal Click the button after click the type of animal pictures which has been set up and then delete the type of animal Purchase edit box empty and restore pictures to the factory initial state Save Click to save new animal names and the edit box can t be inputted OK Click the button after clicked the animal to select it Cancel Abandon the current operations return to the former interface 35 Browse Director
29. emplate mode Non template See the section 1 6 of present chapter for the non template mode Template Test with template In the template mode select all or part tests of the one template and click OK to begin testing with template You can amend the test of template or increase the custom template See the section 1 6 of present chapter for more information 1 The template list show all the template click one and the background will become blue The selected template Example background is blue as figure 7 7 at the same time system will prompt the selected Example template with blue words at the bottom of the window 2 The test list of template shows all the tests of this template There is a check box in front of the test respectively If the check box is selected the test is selected For example as figure 7 7 all the projects of the template Example are selected Then click the OK to begin testing with template and test the tests in turn Please see the 2 2Templet Test Process of chapter 7 New Click it to enter the Template Parameter interface and add new a template Edit Click it to enter the Template Parameter interface and amend the project of present template Delete Click it to delete present template 45 OK Select template on the Template List and then select the test on Test list of template click it to enter the test interface to begin testing the selected te
30. enter the IP setting procedures if no network is selected this button will disappear in the interface Touch Calibrate Click it to pop up the sure to touch calibrate dialog box System enters the touch screen calibration procedure when the Yes button is clicked If touch screen isn t selected this button will disappear in the interface 27 3 1 Touch Screen Calibration Click the Touch Calibrate in system setting interface system pops up the dialog box as figure 5 3 Yet Biochemical Analyzer Sure to touch calibrate Figure 5 3 Click Yes to enter the interface in figure 5 4 Carefully press and briefly hold stylus on the center of the target Repeat as the target moves around the screen Press the Esc key to cancel Figure 5 4 According to the tips on the screen user can operate it with a touch pen When calibration is accurate after clicked five times you can click once on the screen to store the information and exit if not system will automatically re enter the calibration status Hint User can only use this function when the touch screen is purchased 28 3 2 IP Setting Click IP Setting in the system setting interface enter the interface in figure 5 5 Ls Make Mew Connection Figure 5 5 Double click network connection icon in the interface enter the IP setting interface shows in figure 5 6 DC 1X4 Settings OK x IP Address Mame Servers An lp address can be
31. ey and enter key on the device keyboard are as follows 1 Select previous item of the current one function is equal to 1 key on the keyboard Select next item of the current one function is equal to key on the keyboard lt Select left item function is equal to key on the keyboard Select right item function is equal to key on the keyboard Enter Move focus to next control which can receive it function is equal to Tab key on the keyboard 3 Interface of the keyboard There are 9 keys in the keyboard The function of the key is as follows Figure 3 5 lt t gt Sy eel a Cem Ener J 1 OX ha Stet j Key ASP Paper Rinse Figure 3 5 interface of the keyboard 16 3 1 Key Control the soft keyboard among the off status English language input status Chinese language input status See the section 1 1 soft keyboard window for more information 3 2 Paper Control the printer paper press the key to move paper and loosen to stop 3 3 Rinse Press Rinse to control the machine rinsing When you press it once the device would continuously aspirate the cleaning agent through the flow channel Press it again to stop rinsing Please notice that it is not effective to press Rinse when the machine is in testing The function of this key is the same as the Rinse button in test interface 3 4 ASP Press ASP to aspirate testing liquid which is
32. is equal to key on the keyboard lt Select left item function is equal to lt key on the keyboard Select right item function is equal to key on the keyboard Enter Move focus to next control which can receive it function is equal to Tab key on the keyboard 14 2 12 List Box 1 2 TestDr2 3 TestDr3 There is no focus currently No item selected 1 TestDri 2 TestDr2 3 TestDrs3 There is no focus currently Select third item There is focus currently No item selected TestDr3 There is focus currently Select second item When control has focus the function of direction key and enter key on the device keyboard are as below 1 Select previous item of the current one function is equal to 1 key on the keyboard Select next item of the current one function is equal to key on the keyboard lt Select left item function is equal to key on the keyboard Select right item function is equal to key on the keyboard Enter Move focus to next control which can receive it function is equal to Tab key on the keyboard 2 13 Date Time Picker 2007 05 08 11 41 12 There is no focus in current Forbidden status 2007 05 E 11 41 12 There is focus in current 15 5 27 2007 May 2007 T 3 10 17 24 31 5 27 2007 There is focus and shifted down When control has focus the function of direction k
33. lay the Add Test Records interface on the following figure then add a selected test record in the Sample records list interface Edit Test Click to display the Edit Test Records interface on the following figure then edit a selected test record in the Sample records list interface Delete Test Click to delete a selected test record in the Sample records list interface 62 3 Query sample records Click Query in Sample Records to show the following window and input the query terms then click OK to query the result is displayed in the Sample records windows Input Condition Master Name Sample SN Phone M Date From 2008 4 8 Animal Name To 2008 4 8 Species Fuzzy search Cancel Figure 11 2 Sample SN Input the sample SN that you query the number can be part of the whole sample SN and letters within 16 Master Name Input the name that you query the words can be part of the whole name and letters within 16 Phone Input the phone number than you query the words can be part of the whole number Animal Name Input the name that you query the words can be part of the whole name and letters within 16 Species Set animal species Date From Input the prior date Date to Input the later date Date Option Select to query according to the setting date Fuzzy Search select to fuzzy search For example if input 1 as the Sampl
34. le in the instrument It is easy operation with small dosage reagent to select flow cell It could reduce crossed pollution if user selects cuvette Check Colorimetry Cell or Cuvette Position Automatic sensing of cuvette flow cell insertion Data Transmission Method A method of data uploaded from device to computer by RS232 and use ASTM protocol or not Edit Edit parameters above Save Save the parameters user edited Cancel Cancel to edit Set Printer Click to enter the Printer Set interface Instrument Maintenance Click to enter the Instrument Maintenance interface Data Maintenance Click to enter the Data Maintenance interface System time setting area System Time Display and set system time Edit Click to edit date Save Save the date user amended Cancel Cancel user s edit 25 2 Printer set If you selected external printer the button Set Printer becomes available Click it to open the print option interface as figure 5 2 shows Print options Print P PCL Laser Print Area Orientation Prot o LPT1 PULE Landscape A Path OLocalis O Portrait LD Margins mm Paper SizetZ i a4 es LeftiE 25 4mm Tope es 4mm w Drat ModeiF Advanced y a i 125 Advanced a Chromatic C RightiR 25 4mm Bottom Bh 23 4mm Figure 5 2 Printer Set printer model If you use HP laser jet please select PCL Laser It is enough if you set the pri
35. m the list OK Click to save and return to interface 7 2 Cancel Click to return to interface 7 2 without saving 43 6 QC Parameter Click QC Parameters in the Parameter Setting Jinterface enter the QC Parameters interface show as figure 7 6 OC Parameter Test Name ALT Number One Number Two Number Three Batch Me Batch Me l Batch Mo Mean Value 10 000 Mean Value 0 000 Mean Value 0 000 Min Value 0 000 Min Value 0 000 Min Value 0 000 Figure 7 6 QC Parameter Setting Please input the parameters according to the operation manual of Control material This instrument allowed a maximum of 3 Control test Batch No It means the batch number of the control material Mean Value The mean value of the control material Min Value It means the minimum value of the control material OK Click to save the QC parameter setting and return to Test Setting Parameter interface Cancel Click to return to the Test Setting Parameter interface without saving 44 7 Select template In the main interface as figure 4 10 click Test and enter the Select Test interface after select one animal then click Template to display as figure 7 7 oF Select Test A RT A 10 07 40 Q Non Template Template Template Template Parameter Example Selected Example 1 Template list 2 Template test list Cancel Figure 7 7 the Select Test interface In the t
36. meter of the new test Select QC Jand set the QC parameters Select Calib Para and set the calibration parameters Click Save to save and exit 38 Test Parameter Marne Full Mame Reagent Batch Na Rgt Mant Primary Wavelength Units OL Ref Upper Limi bo Secondary Wavelength Test Method End point ReflowerLimit o 000 Temp p T E Factor p 000 Linearity jooo Sample vou Goo Dea Time GE Lower Limit fj o0 Reagent Voli fig Measuring Times f Linear Error 00c a Aspirate Vollu nn Blank Method Mo hank calib Para 7 2 Parameter Setting Name A brief name of the test e g ALT A new name within 15 letters must be given before any other operation of the new test Full Name The full name within 50 letters of the new test e g Alanine Aminotransferase Reagent Batch No Reagent batch number within 15 letters Rgt Manf Reagent manufacture name within 50 letters Primary Wavelength There are 7 levels of wavelength selectable 340 405 505 546 578 620 and 670 and one user define wavelength available Secondary Wavelength Please set the secondary wavelength when in double wavelength method Temp Testing temperature with R T Room Temperature 25 C 30 C 37 C selectable There is no temperature control in atmosphere mode Sample Vol ul Sample Volume Please pay attention to the proportion between Sample and Reagent in the operati
37. mit gt Lower Limit Linearity Please set the Linear Upper Limit 20 and Lower Limit 20 according to the user manual of reagent to control the testing data in the normal range Please regulate the proportion of the tested liquid when over range data occurred Linear Upper Limit 2 Linear Lower Limit Lower Limit See Linearity Linearity Error It is used to control the Linear of testing data in the normal range The instrument will alarm when over range data occurred Preview It is used to preview the data and parameters to be printed Print It is used to print the data and parameters QC Para Click to set the control parameters Calib Para Click to set the calibration parameters Save Click to save the settings and return Cancel Click to return without saving Hint About the test method End point It means to test the absorbency of the tested liquid after the reaction between Reagent and Sample finished Then the concentration will be calculated according to the Lambert Beer equation Kinetics It means to test the absorbency of the tested liquid continuously during the reaction And test the slope during the linear reaction Then the concentration will be calculated according to the Lambert Beer equation 40 Fixed time It is a especial example in Kinetics It means to test the absorbency of the tested liquid continuously during the reaction And measure the absorbency of two different poi
38. n pull the plug and do not draw the wire Do not put container with water or small metal object on top of the instrument to avoid water or metal object falling in the inner which may result in short circuit and damage of the instrument The instrument should use power wire with three cores and make sure grounding well Clean the flow cell to make it clear after using it and turn off the power to prolong the usage life of the lamp VI Chapter 1 Brief Description 1 Appearance 1 Front view l 6 2 7 3 8 4 9 5 10 11 12 1 Cover of printer 2 Face shell 3 Removable cover 4 Pipette 5 Aspirating key 6 Display screen 7 Logo 8 Speaker 9 Bottom shell 10 Keyboard 11 Power indicator 12 Mouse 2 Back view AC INPUT E EN D m POWER ON OFF Ge aS fae m aW _ F2A250V ef 1 Power switch 2 Fuse socket 3 Power socket 4 Fan 5 SD card socket 6 USB socket 7 RS232 socket 8 Ethernet socket 9 Nameplate 10 Pump 2 Functions m Colorized windows interface m Double channels test you can also use single use cuvette available to eliminate crossed pollution m Advanced optics test system built in 8 filters 340 405 505 546 578 620 670 and one optional filter available m Methods available as follows
39. n rinse is finished system prompt that you can turn off safely as follow then you can turn off the power switch directly It can be powered off now Figure 14 3 Hint To prolong the life of the instrument make sure turn off the device according to steps above mentioned 70 Chapter 15 Software Maintenance BS600V provide a powerful software system maintenance functions in some cases the need to safeguard systems operating steps are as follows 1 Start the process of system maintenance If the state apparatus in the boot make sure your system closed and the closure of power equipment Press Enter on the keyboard instrument panel simultaneously turn on power equipment open up the key until the show interface shown in Figure 15 1 System Maintenance Option O Update Restore factory system settings Restore program files to last edition Figure 15 1 Update Click to start the implementation of the updated the system automatically updates search documents and complete the update process Restore program files to the last edition Select the Restore option and click OK to restore a recent escalation of the version Restore factory system settings Select the Restore factory system settings option and click OK to restore factory system settings OK Click to start the implementation of the selected option Cancel Click to suspend the implementation of the selected
40. nd direction of the flow cell Figure 2 3 TE y E E Ep chee tg wc T The thicker one is Waste pipe The slimmer one is Aspirate pipette Figure 2 3 Push the aspirate pipette out as Figure 2 4 Then you can put back the cover Make the length suitable for your tubes Figure 2 4 The waste pipe may be conglutinated in storage and transport For your first time of using it may not aspirate normally and cannot pass the self test Please loosen the pump lock press down the handle as Figure 2 5 cancel the retrying of self test Figure 2 6 rinse for several seconds at the main interface till the pump can roll normally Figure 2 5 Biochemical Analyzer Self test unpassed Retry Figure 2 6 Chapter 3 Basic operations 1 Operations of soft keyboard 1 1 soft keyboard window A soft keyboard set in this instrument Users can press key in the keyboard interface or click the icon ES in the window The soft keyboard can changed another among closure English input The icon of soft keyboard shown as figure below Figure 3 1 Soft keyboard 1 2 Move the soft keyboard window In the Input interface of soft keyboard window hold the left key and move the mouse to a needed location then loosen left key 1 3 Instruction of soft keyboard key Delete the character before the cursor Tab key Change the focus CAP key Switch English letter between capitalization and lowe
41. non template gt Template Test with template Select all or part tests of one template and then click OK to begin testing with template You can amend the tests of template or increase the custom template See the section 7 9 of present chapter 37 Test list displays all current tests The background color of test would turn blue when click the test Figure 7 1 For example the selected test ALT appear blue background color and ATL is displayed in down side of the window in blue color Then press OK to enter test interface New Click to enter Edit Test Parameter interface for adding a new test Edit Click to enter Edit Test Parameter Jinterface for amending parameters for selected test Delete Delete the selected test OK Click to enter test interface for testing after selecting the test in test list Cancel Cancel this operation return to previous interface amp Hint gt The operation select test and press OK is equal to double click test in the test list gt New test is custom test Existent tests are fixed before the instrument leave factory User only delete custom test gt Deleted test would delete relevant control calibration sample records and so confirm the operation is correct before delete System would offer operation notice 2 Add New Test Inthe Select Test interface in the non Template mode Select New Test display as figure 7 2 and set every para
42. nt selection is No blank Kia aeS aa 7 Hide or get down the dialog box by pressing the little triangle Reagent blank Sample blank hold focus and get down dialog box When control holds focus the function of direction key and enter key as follows Choose previous entry of the current one function is equal to 1 key on the keyboard Choose next entry of the current one function is equal to key on the keyboard 13 lt Move focus to previous control which can receive it function is equal to Shift Tab key on the keyboard Move focus to next control which can receive it function is equal to Tab key on the keyboard Enter Move the focus to the next control which can receive it the effect as same as Tab key 2 11 Combo Box can write in u Ba The combo will display a flickering vertical line I or letter is selected when hold focus the selected letter have blue background Otherwise it means this combo box have no focus Ws y Forbidden status Hold focus letter is selected and the background is blue Hold focus letter is selected and the background is blue and the combo box is shifted down When control has focus the function of direction key and enter key on the device keyboard are as follows 1 Select previous item of the current one function is equal to 1 key on the keyboard Select next item of the current one function
43. nter the options below are all unnecessary Port Default LTP1 please keep it Path Network shared printer It is not available now Paper size Default A4 all the usable printers use A4 paper Draft mode Print lightly to save ink or toner Print area Default full please keep it Orientation J Default Landscape please keep it Margins Set the margins of each side Default 25 4mm 1 inch Press OK button to save the settings Available printers _feme _ seo te Brand Model Type 2014 PCLiaser o mea o inkjet Pi Prsoon ra er 2 Pg ee P3 ProK5400d ae ME Office 70 mew nor ME Office sow Nk et 5 ProL7380 O inkjet 6 ProL7580 Inkjet 460cb Ba ea ProK850 Ink jet 26 3 Instrument Maintenance Press Instrument Maintenance in System Setting interface then enter the Instrument Maintenance interface as figure 5 2 Instrument maintenances Set Wave 340 ead Abs Re i el Time zero Accumulated tme 0 2 h Cancel Figure 5 2 Set Wave select wavelength in the combo box then click this button to set wave Read ABS click it to read AD and ABS Time Zero click it to clear the accumulated time after you replace the lamp Pump Coe correct it to adjust the aspirate volume error Temp Coe correct it to adjust the temperature error Edit Edit parameters above Save Save the parameters user edited Cancel Cancel to edit IP setting Click it to
44. nts during the linear reaction Then the concentration will be calculated according to the Lambert Beer equation 3 Test Parameters Edition Enter Select Test testing with non template Select a test in the interface as figure 7 1 e g ALT Click Edit or click Para in Test interface to display the interface as figure 7 3 Click Save to save after finished parameter setting See part 1 of this chapter about Parameter Setting oF Test Parameter a aol Full Name a Reagent Batch Mo li j Rgt Mant MAKER Primary Wavelength 340 il Units ly Ref Upper Limit 57 3 Secondary Wavelength Jone EB Test Method Kinetics Ref Lower Limit 8 20 Temp Factor l4iso o00 Linearity io00 000 Sample Youbi h2 Delay Time s j5 Lower Limit p ooo Reagent voltu Boo Measuring Timefsii o Linear Error 0 010 o Aspirate Vol ul jooo Blank Method No blank gt Preview Print GL Para Call Para Sae Cancel Figure 7 3 Testing Parameter Setting lt gt Notice 1 The name of test could not be changed by editing in an existed test 2 The system will alarm Factor or calibration information may be invalid if no calibration information after changing the parameter of Reagent Batch No Primary Wavelength secondary Wavelength Temperature Test Method Delay Time Measuring Time and
45. on manual of Reagent Reagent Vol ul See Sample Vol ul Aspirate Vol ul It means the aspirating volume of tested liquid each time We recommend it no less than 400ul each time to make sure the accurate result Standard volume 500ul Units Test unit within 15 letters See the reagent manual Test Method There are three methods selectable End point Fixed time Kinetics Factor User can input the factor with the keyboard according to the operation manual 39 of the reagent Or the instrument can test standard materiel to calibrate the factor after inputting the standard parameters If the calibration method is non linear user can calibrate only Delay Time s It means the time before the tested liquid ready Normally it is 5 seconds in End point testing For Fixed time and Kinetics testing please see the operation manual of the Reagent Measuring Time s It means the reaction time for the calculation The time should be 0 for the reaction is finished it could not be input by the user And the time should be more than 0 when the test method is Fixed time or Kinetics Blank Method It is including Reagent Blank Test Sample Blank Test and No blank Test Control Test and Standard Test need control and standard blank Ref Upper Limit The reference upper limit maximum of normal testing data gt 0 Ref Lower Limit The reference upper limit of normal minimum testing data 20 Upper Li
46. option 71 2 Update Insert the SD or flash card storing the updated file select Update and click OK system shows the dialog box in figure 15 2 Yet Biochemical Analyzer Sure to update it Figure 15 2 Yes Click to start the implementation of the updated t system automatically search files and complete the update process No Click to suspend the implementation of the updated and returned to the System Maintenance interface 3 Restore You can restore the former version after updated Select Restore and click OK in figure 15 1 Show the dialog box in figure15 3 Yet Biochemical Analyzer Sure to restore it to last edition Figure 15 3 Yes Click to start the implementation of recovery the system will automatically recovery to last updated version before No Click to suspend the implementation of recovery and return to the System Maintenance interface 72 4 Restore factory setting Select Restore factory setting and click OK show the dialog box in figure 15 4 Yet Biochemical Analyzer Sure to restore factory system settings Figure 15 4 Yes Click to start the implementation of recovery the system will automatically restore factory setting No Click to suspend the implementation of recovery and return to the System Maintenance interface 73 Chapter 16 Routine Maintenance Vet biochemical analyzer is a clinic precision analytical instrument
47. perly 2 Check the connect of the pipette and the flow cell 3 Pipette is either too long or too short 4 Pipette may be jammed clean it 5 Flow cell is too dirty Abs of the water blank is too high 1 Clean the flow cell 2 Change the distilled water 3 Check the lamp Repeatability is not good 1 There are air bubbles in the flow cell clean the flow cell 2 Check the aspirating of the pump 3 The quantity of the reagent is too little increase the quantity of the reagent 4 Change the lamp 5 Reagent is polluted The quantity drew by the pump varies from 1 Check if the pipette is jammed time to time 2 Change the pipe of the pump Quality control value not in target scope 1 Check the period of validity 2 Check if the parameters is correct 3 Make sure the QC material is not polluted 77 Chapter 17 Packing Storage and Transportation Put the unit in protective poly foam and then put it in the wooden box Take out the unit and power them on for four hours if the units have been put in stock for more than 6 months and put them back according to the instructions marked outside the carton Do not stack the units or let the units contact ground directly Remember to leave some space between the products and walls and roofs Shock absorption has been deliberately considered when the parking is designed and they are suitable for air railway road and sea freight Do not shock or place the products upside
48. plate Sample Test Next Sample Test 1 The Rinsing process is not mandatory process in order to avoid crossed pollution Rinse with distilled water after the completion of each test 2 Please follow the blank test of the Standard liquid when the parameter setting is Standard Blank Test 8 2 Sample Testing Procedures E g Test ALT with Sample Blank gt 1 Turn on the instrument to the main menu Click Test to Select Animal interface select a animal and click OK enter Select Test interface Select ALT and click Enter or double click ALT to the Test List interface Click Edit Test to enter the 49 Test Parameter Setting interface Please set the parameters if the parameters existed could not comply with the operation manual of the Reagent 2 The system will adjust the Lamp and Temperature automatically The real time temperature will be displayed on the top right corner of the interface The operation notice Please aspirate distilled water will display after the adjustment 3 Press ASP under the pipette or on the keyboard to aspirate distilled water The operation notice Please aspirate sample blank will display after distilled water test 4 Press ASP to aspirate sample blank See the operation manual of the reagent and wait for the sample blank test The system will alarm Factor or calibration information may be invalid if there is no valid factor after the blank test or
49. rcase 2 Windows Routine Operation amp Adnex s Hint You can skip if you are familiar with the operation of Microsoft Windows system 2 1 Mouse Mouse is available by connecting USB port of the device such as Figure 3 2 shows Figure 3 2 Mouse Put mouse on the stable worktable hold the mouse and move it Then you can see a cursor like A moving on the screen Cursor of mouse there is a cursor like A moving on the screen when we move the mouse we call it mouse cursor The mouse cursor may change to different shapes Cursor means some program is being processed and the user need wait Cursor means that information can be input after the cursor Click single click the left key of the mouse means press down the left key of the mouse and then loosen it but not move the mouse during the course Right click press down the right key of the mouse and then loosen it but not move the mouse during the course Double click click the left key of mouse two times swiftly 2 2 Windows Window is an interface for information display and operation so window is also called interface General speaking put one or several control window will have title bar and control button etc Such as Figure3 3 amp 3 4 shows Vet Biochemical Analyzer v4 hr E TEST oF ae SYSTEM Figure 3 3 Full Screen Window Title Bar Close Button Cai bration Records QC Records System Setting Figure 3 4 Window with titl
50. rn to the testing interface Hint The system will check the sample records before aspirating Interface as figure8 5 will display if the record has existed in the records Yet Biochemical Analyzer Figure 8 5 Yes Click to make the new test instead of the record No Click to display figure 8 4 to input another sample SN lt Hint Before user click Aspirate to aspirate liquid interface as figure 8 6 will display then user can input sample info 51 Input Sample Info Animal Name Master Name Animal Sex Wer Phone Animal Age Y lolim cance _ Figure 8 6 Animal Name Input the animal name here Animal Sex Input the animal sex here Animal Age Input the animal age here Master Name Input the master name here Phone Input the master s phone number here OK Click it to save the info Cancel Click it cancel and return to the testing interface Also user can edit the sample information in the sample records interface Hint If anything is abnormal in distilled water test system will suggest as shown in figure 8 7 Then system return the distilled water test interface after clicked OK and user can not continue testing process At this time user can retest water blank after rinsed the pipe to eliminate abnormal gaps If user can not resolve the problem through retried several times you can contact the designated maintenance points Yet Biochemical Analyzer Dis
51. st Cancel Quit operating the selected test back to previous windows Hint gt The new template is user defined Users can only edit or delete the user defined template 8 New template In Select test Jinterface testing with template Click New display as figure 7 8 Input name of new template and select the test of this template then click OK to add a new template Template Parameter Ge 70 A ss0802 Q 5 Template Parameter system test list Figure 7 8 Template Parameter interface 1 The system project list shows all the tests except tests of the selected template 2 The template test list shows all the tests of present template gt gt Select one or more tests on system test list and click the button to add the selected test to present template lt lt Select one or more projects on template test list and click the button to delete the selected test from present template OK Finish editing present template and save Cancel Quit editing present template 46 9 Edit template In Select Test interface testing with template click Edit and show the interface as figure 7 8 then edit the test of the template and click OK to finish editing See the section 8 New Template of chapter 8 for others 47 Chapter 8 Sample Test 1 Sample Test Interface Select the non template mode inf Select Test interface then select one and click OK to enter Test interfa
52. the packing list Any question please contact the sales personnel or distributors 2 Make sure write the service guaranty earnestly and mail the product guarantee card to manufacturer Otherwise it may restrict your service offered by our company 3 Please read all the packed materials and store them properly Notice and the hint mark referring to safety A Warning The information you should know about how to avoid being hurt during the operation and consult the marks in the operational manual O Notice The information you should know about how to avoid any damage to the instrument Hint The important hint information during the operation What you should know This instrument should avoid working in humidity condition or with corrosive gas If peculiar smell or smoke generated during the operation please cut off electricity in time and notify the manufacturer or agent for maintaining The operational personnel should avoid touching the inner circuit and only the certificated personnel can repair the instrument The operational and maintain personnel should wear rubber glove when operating or repairing Please treat the trash as medical garbage lt P Notice Keep the working environment aeration avoid strong electromagnetic interference dust sunshine and other strong direct light Make sure the instrument is placed on the worktable stably Do not damage the electrical wire hold plug tightly whe
53. the parameters has been changed after done calibration last time See figure 8 3 This notice means the user must input the correct factor or calibrate before sample test The system will notice Please aspirate Sample after valid factor occurred gt Yet Biochemical Analyzer Factor or calibration informaton may be invalid Please input the factor or calibrate again Figure 8 3 5 Please confirm the Sample SN before test then press ASP to aspirate the sample See the operation manual of reagent Click Rinse Jor press Rinse on the keyboard to aspirate distilled water to rinse after every test to avoid crossed pollution and keep the instrument clean Click Rinse or Press Rinse again to stop rinsing The system will save the result data automatically And the instrument will print the result automatically if Print Online has been settled The system will be ready for next sample test The Sample SN will go on automatically if the number is figures Or it will be cleaned Start next test when the system notice Please aspirate sample blank 50 Hint The system will check the Sample number before aspirating Interface as figure8 4 will display if the Sample SN has not been inputted Input sample SN Sample SN can t be null Sample SN er z Figure 8 4 Sample SN Please input the Sample SN of current test OK Click to save the sample SN Cancel Click to cancel and retu
54. tilled water test fail Please check Figure 8 7 Hint If Abs value is transnormal in distilled water test system will show the dialog box in figure 52 8 8 Yet Biochemical Analyzer Distilled water abs is transnormal Retry Figure 8 8 Retry Click it to retest distilled water Cancel Click it to continue testing behind Hint When a reagent blank is selected in the project parameters system will store the reagent blank value after tested if the value is greater than 0 Then while device tests the same project next time system will show the dialog box in figure 8 9 Yet Biochemical Analyzer Do you want to retest reagent blank Figure 8 9 Yes Click it to retest the reagent blank No Click it to cancel testing the reagent blank system will calculate the result with the stored reagent blank value 53 2 2 Test with template Select Template Test the first project of the template Distilled Water Test Blank Test Sample Test Test next sample until all the samples with present project have been tested Click Next Project button and then begin testing next project until all the projects of present template have been tested 1 The Rinsing process is not mandatory process in order to avoid crossed pollution Rinse with distilled water after the completion of each test 2 Please follow the blank test of the Standard liquid when the parameter setting is Standard Blank
55. tte If the pipette or flow cell is jammed by any other substances you can clean it with an injector If the pipette is damaged or jammed badly you d better replace it with a new one The way is as follows m Open the removable cover m Pull up the flow cell m Take the pipette off from the flow cell at the entrance on one side of the new pipette pull up the fixed pipe the widest pipe and make sure the fixed pipe and the pipette have a superposition for 1cm then fix the fixed pipe onto the entrance of the flow cell m Pull the pipette though the fixed metal pipe 3 Replace tube of the pump m Press down the handle ip m Take off the screw as figure15 2 and take off the cover of the pump m Take out the tube as figure 15 3 m Take off the pipe of the two sides as figure 15 4and repalce it Figure 16 2 Figure 16 3 Figure 16 4 4 Replace lamp m Take off the screw m Disconnect the connection of the power supply m the lamp part can be taken out m Replace it and tighten the screw and connect the power supply Power supply Figure 16 5 76 4 Trouble shooting No display on the screen after the unit is 1 Check power supply switched on 2 Check the power cord and plug 3 Check if the fuse is broken The lamp of the instrument cannot be 1 Check the power supply before replace lightened the lamp 2 The lamp is damaged replace it with a new one No liquid in the flow cell 1 Check if the pump is running pro
56. ure 4 5 Distilled water is tested entering the main interface Figure 4 1 boot strap Hint Press Rinse once to aspirate cleanout liquid to rinse the flow system in no distilled water testing Press Rinse again to finish rinsing Do not test distilled water while it is in rinsing It only could be operated after the rinse is finished 2 Interface of boot strap Turn on the power the system loading interface is as follow while the power light is on Figure 4 2 System is loaded and turns to system welcome interface Figure 4 3 Figure 4 3 20 Wait for auto check finishing Figure 4 4 Auta check Figure 4 4 Wait for distilled water test Figure 4 5 Distlled water test please aspirate Figure 4 5 Put the pipette into distilled water then press ASP to aspirate the distilled water Device start distilled water testing with each wavelength after aspirating Figure 4 6 Distilled water test Figure 4 6 When self test and distilled water test is qualified device automatically enters the main interface shown in Figure 4 9 Otherwise system suggests that in figure 4 7 1 and 4 7 2 if user chooses to retry device will begin self test and distilled water test again Biochemical Analyzer Self test unpassed Retry
57. y Please select file Storage Card Dog jpg Cat jpg Sheep jpg Figure 6 3 Select file Hint gt Double click the picture of some animal is equivalent to click the picture and OK gt The format of the picture must be Jpg format and size is less than 50KB gt Delete animal species will remove all relevant records gt When user need to add new types of animals after 8 defined animal species have been set up user could add new types of animals by deleting some of the definition of animals 36 Chapter 7 Test Setting User could select test in select test interface If there is no test user required user could add test Input test name and correct parameters when add test then save it Ensure test parameters is as the same as the reagent manual The parameters maybe different by different reagent manufacturer please correct parameters when change the reagent manufacture 1 Select test In the main interface as figure 4 10 click Test andenter Select animal select some animal and click OK then enter Select Test interface click Non Template display as the figure 7 1 Non Tem plate Template GST a HBL PK IgG IgM C3 C4 IP Test list Figure 7 1 Select Test Interface Non Template Non Template Test with non template The test list will display all tests Select one and click OK to begin testing with non template See the Chapter8 lt Test with