Home
Netbiter Argos User Manual - ER-Soft
Contents
1. Netbiter Argos User Manual For the Netbiter EasyConnect products HMS Industrial Networks AB Rev 1 00 Post address Visitor s address Telephone E mail Box 4126 Stationsgatan 37 46 35 17 29 00 info hms networks com 300 04 Halmstad 302 45 Halmstad Fax Web SWEDEN SWEDEN 46 35 17 29 09 www netbiter com 4a Netbiter Argos AIS User Manual 44 Rev 1 00 History Reversion Date oeseri Jamo Terminology Netbiter Argos Data The Netbiter Argos data center is a solution that collects Center and stores data from connected Systems The Netbiter Argos contains various features such as alarm management reporting capabilities and much more Netbiter Argos Account A Netbiter Argos Account is an user account from where you can manage and administrate connected systems Netbiter Argos Project Connected systems can be grouped into Netbiter Argos Projects in order to get a better management overview Example Systems belonging to a specific address customer or similar System A System is the Netbiter Gateway and Devices put together as a unit A System can consist of multiple Devices but only one Gateway Gateway A Gateway can be either an EasyConnect webSCADA unit or a third party product that is compatible with Netbiter Argos Device A Device is the equipment that is to be monitored and is connected to a Gateway Examples of devices diesel generator controller UPS s energy meters or a PLC s net
2. 4a Netbiter Argos AS User Manual 44 Rev 1 00 2 Fill in the information on the Add visualization parameter screen Add visualization parameter Device MyFirstSystem gateway Group 0O Parameter Analog input 1 0 10 Description Analog input 1 0 10 E Unit V E Scaling 1 Offset io A Number of decimais E Valid range Enumeration save cancel Device The device that the parameter comes from Group The template Group that the parameter comes from Parameter The visualization parameter that is being added Description Will be the name used on the visualization parameter As default the Description is the template parameter Name By marking the checkbox on the right the description can be changed Unit The unit for the parameter Is as default the Unit stated in the template By marking the checkbox on the right the Unit can be changed Scaling Is used when the parameter value needs to be scaled before it is visualized The parameter will be divided with the scaling before visualized Ex parameter value 510 Scaling 10 gt 51 0 will be visualized Offset Is used for adding a number to the scaled parameter value Ex Scaled parameter value 51 0 Offset 5 3 gt 51 0 5 3 56 3 will be visualized Number of Determents how many decimals will be used when it is visualized decimals Valid range A parameter must be in this range in order to be set Enumeration Fo
3. Is used for adding a number to the scaled parameter value Ex Scaled parameter value 51 0 Offset 5 3 gt 51 0 5 3 56 3 will be logged Determents how many decimals in the parameter that will be used for the logged of value A set parameter must be in this range in order to be set For parameters that are of enumeration type in the template the enumeration can be overridden by clicking the checkbox at the right of the row The parameter value can be presented with the string definition for a value were the valus are separated by Ex 1 ON O OFF The log interval determines the interval between two log points Can be from 30sec up to 60min depending on subscription added to the System Value The parameter value are stored Delta The difference between the current point and the one before is stored Ex Point i Point i 1 is stored 3 Click Save and the Log parameter will be added Cancel will close the window and discard all changes 2 3 Add Visualization parameter Visualization parameters are used for presenting parameter values on the overview page or ona Dashboard 1 Click the add visualization parameter button under the Visualization tab Device configuration Logging Alarms Gateway settings show Advanced Config Device Device profile Group Parameter Description Unit Log interval Log share Action _add visualization parameter netbiter HMS Industrial Networks AB Page 13 51
4. properties x eg position 366 181 size color parameter qP min value 0 max value 100 Close J position The position of the object on the drawing size The size of the object color The text color can be set by clicking the colored rectangle R E G gt is B gt B E 6 6c After selecting color press OK parameter The Parameter connected to the object min value The minimum value displayed by the object max value The maximum value displayed by the object There are different types of components to choose from in the Public Library Gauges Graduated Tanks Temperature Bars m F100 4 r fe 80 90 f 80 lt 9 40 70 20 20 60 s g Y HMS Industrial Networks AB netbiter Page 30 51 4a Netbiter Argos ASG User Manual 4a Rev 1 00 3 4 6 5 Alarm In order to add an alarm indicator click on the add alarm tool and on the position where the alarm indicator should be placed a As default it will indicate the alarm with the highest severity level The alarm indicator will have different colors depending on the severity Indeterminate By double click on the alarm indicator the properties window will appear properties x EH H position 466 159 size 32 32 opacity 1 alarm Summary ne i Close position The position of the object on the drawing size The size of the object Opacity Determines the transparency of the text from O to 1 were 1 is solid a
5. Click on the add button in order to connect additional Templates to the Device Profile To add Logging Visualization amp Alarm to the Device Profile se section 2 2 2 3 and 0 The Device profile is automatically saved during the configuration netbiter Netbiter Argos 44 AS User Manual 4a 6 1 3 6 1 4 6 2 Rev 1 00 Copy Device Profile Click on the Profiles tab under the Management menu Click on the Copy link on the row of the Device Template that should be copied _ User defined device profiles Protile type Profile name Virtual Test Profile Edit The Edit profile screen will appear with an exact copy of the original Device Profile The default Profile name is Copy followed with the original Profile name Se section 6 1 2 for information about how to editing the Device Profile Remove Device Profile Click on the Profiles tab under the Management menu Make sure that the Device Profile is not used by any Systems in the Account before it can be removed in a safe way Click on the Remove link on the row of the Device Template that should be copied _ User defined device profiles Protile type Profile name Virtual Test Profile Edit Global profiles A Global Profile is a fixed Profile that is not possible to edit The Global Profile can be used in two ways 1 Added as instructed in section
6. 3 Click on the Submit button netbiter
7. Device profile Is the profile that will be connected towards the Device 4 Click Save and the Profile will be assigned and Cancel will close the window and discard all changes NOTE The device needs to be added before a Device Profile can be connected see section 2 1 For information about how to make a Profile see section 4 netbiter 4a Netbiter Argos AMIS User Manual 4a Rev 1 00 2 8 Server side alarm Server side alarms are configured in the Configuration tab for the System E Status Configuration Dashboards Map Backup Firmware Mobile network Properties 2 8 1 Offline alarm The Offline alarm will go active if Netbiter Argos has not had any contact with the System for approximately 20 minutes _Server side alarm configuration Edit the alarm configuration settings Offline alarms No K2 NOTE For a user to receive an Offline alarm the user needs the right access level see section 4 2 9 Positioning the remote system 1 Click on the Map tab under the Management menu for the System that is about to be positioned 2 Positioning the system within Netbiter Argos can be done in three different ways 1 Clicking on map 2 Enter the longitude and latitude 3 Using the search bar in the left bottom corner 3 Click the Save button when the System is positioned Contact out Google Latitude WGS 84 N Wo Po fo Longitude WGS 84 fe ello eio fo Get position from
8. J4 Rev 1 00 1 Getting started This section takes over after the User Guide for the individual product and describes the procedure for getting the first system up and running 1 1 Create a Netbiter Argos Account 1 Open a web browser and navigate to https www netbiter net 2 Click the Create an account link in order to create a new account User Password Log on 3 Fill in the account information in the form and store your Account name and password as these will be used when accessing the account Fields marked with a red asterisk are required for creating the account Account name Password Repeat Password First Name netbiter argos Last Name Netbiter Argos Online management portal Company Df rate CT CO Country Select DEVICE ID 353235 784249253 ACTIVATION CODE PELIN Phone E mail Confirm E mail Device ID 123A4EFB2C2A Activation Code 253BGD32 Device ID 9 Activation Code Accept the terms and conditions _ register cancel The Device ID and the Activation Code are provided in the Netbiter Argos information note supplied with the Netbiter gateway netbiter 4a Netbiter Argos AS User Manual JA Rev 1 00 4 Accept the terms and conditions this is done by marking the checkbox 5 Click on the Register button 6 As the account is created an E mail containing an activation
9. 00 18 00 20 00 22 00 or higher 1 Click on the User name in the List view or Project view to enter the User overview 2 Click the Edit user link 3 The edit user page is divided into three parts e User information e User rights Alarm Scheduling See section 5 3 for more details netbiter HMS Industrial Networks AB Page 39 51 4a Netbiter Argos AS User Manual Ad Rev 1 00 5 4 1 Changing password Changing password for a user is done under the Edit user page And is done by enter a new password on the Change password row and repeat it on the Repeat password row then click save on the bottom of the page User overview Edit user Users information User rights Alarm schedule Ie Username Victor Change password Repeat password First name Victor 5 5 Lost password Lost password can be reset by clicking Lost your password link on the logon screen www netbiter net Online management portal User Password Create an account A new password will then be sent to the email address registered to that account Reset Password Have you lost your username or password To reset your password enter your email below c Make sure you enter the email you registered your user with You will receive an activation mail to confirm the password reset submit cancel netbiter 4a Netbiter Argos AMS User Manual 44 Re
10. 000 historical data points Device Device profile Group Parameter Description Unit Log interval Log share Action add log parameter 2 Fill in the information on the Add log parameter screen Add log parameter Device MyFirstSystem gateway A Group 1 0 Parameter Analog input 1 0 10V Description Analog input 1 0 10V E Unit E F Scaling 1 Offset 0 Number of decimals E Valid range Enumeration Log interval 60 min Log type Value save cancel Device The device that the parameter comes from Group The template Group that the parameter comes from Parameter The log parameter that is being added netbiter 4a FITTS af Description Unit Scaling Offset Number of decimals Valid range Enumeration Log interval Log type Netbiter Argos User Manual Rev 1 00 Will be the name used on the logged data As default the Description is the template parameter Name By marking the checkbox on the right the description can be changed The unit for the parameter Is as default the Unit stated in the template By marking the checkbox on the right the Unit can be changed or added if not available in the template Is used when the parameter value needs to be scaled before it is logged The parameter will be divided with the scaling before logged Ex parameter value 510 Scaling 10 gt 51 0 will be logged
11. 2 7 1 Copied to the Account and becomes a Device Profile the drawback is that if a Dashboard is connected it will be lost on the other hand the Parameter configuration can be changed see section 6 1 1 netbiter User Manual Rev 1 00 4a Netbiter Argos AANS 4a 7 Device Templates A Device Template is describing the Modbus parameters for a remote device It contains information about the available Modbus registers and their data types with scaling and offset predefined Different ways to display the parameters can also be determined in the Device Template for example Enumerations and read write access 7 1 Create a new Modbus device template 1 Click on the Templates menu under the Management menu 2 Click the add template button Ph teva oira Reports i Management Account Projects All systems Templates Profiles All dashboards i Device templates add template upload template 3 Enter a Name for the Template Add template Template type Modbus x Name save cancel 4 Click on the save button in order to create the new Template Cancel will close the window and discard all changes The parameters in the Template are divided into groups as default there are a group called Default group that only will be visible when the Template is used if a parameter is added to it 5 Click on the Add group link in order to add a new group to the template Projects All systems T
12. 4 button the Parameter name will be entered as Description Trigger The trigger work together with value stated in the value field Equal to f the parameter is equal to the Value Not equal to If the parameter is not equal to the Value Less than f the parameter is less than the Value Greater than f the parameter is greater than the Value Any bit If any bit in the parameter is equal to the Value 0 1 Neither bit If neither bit in the parameter is equal to the Value 0 1 All bit If all bits in the parameter is equal to the Value 0 1 No response Used to detect if a device has lost contact The value is the number of consecutive time outs for communication with the device Value The value used to fulfill the trigger condition Scaling Is used when the parameter value needs to be scaled before it the trigger comparison is made The parameter will be divided with the scaling before comparison Ex parameter value 510 Scaling 10 gt 51 0 will be compared Offset Is used for adding a number to the scaled parameter value Ex Scaled parameter value 51 0 Offset 5 3 gt 51 0 5 3 56 3 will be compared Class Used to divide alarms into different classes from 1 to 10 No further use implemented Severity Used to divide alarms into different severity levels Indeterminate Critical Major Minor netbiter Warning that are displayed with different colors in the alarm list HMS Industrial Networks AB Page 15 51 4a Netbi
13. and interactive visualizations of your remote system You can add images objects parameters and alarms to be visualized on the dashboard 3 4 5 1 Drawing Tools To access the Drawing click the Edit button on the on the drawing widget Edit a system Drawing netbiter HMS Industrial Networks AB A a abe h A L Page 23 51 4a Netbiter Argos ASG User Manual J4 Rev 1 00 3 Selector Allows you to select individual items on your drawing You can then reposition and re size them by clicking and dragging the mouse gic Static Label Can be positioned and styled to match your needs Dynamic Label This is the same as a static label except that it can be attached to a system parameter to display its value Image Adds an image from the image library onto the drawing Images can be positioned and sized i Dynamic Component Gauges tanks meters etc can be added to your drawing Attaching the component to a system parameter will cause it to animate depending on the parameter s value and the type of component Gauge needles will rotate tank levels will rise and fall etc If you do not want to attach a parameter then the component will simply behave as a static image You can create your own dynamic and static components in Advanced Mode or you can use the components available in our public library EN Alarm This will add a small light bulb graphic to your image By default the graphic will
14. be a drop down next to the value at the page where available enum strings will be selectable A selected value will be written to the address See Enum for more help e Write only value with enumeration The selected value will be written to the address See Enumeration for more help Enumeration The enumeration variables is defined in the following format number string Each enum is separated by a semi colon with no blank spaces Default can be set for Show with enumeration for all values not defined Examples O Off 1 On O Sunday 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday O Weekend 6 Weekend Default Workday Number of Defines the number of decimals to use for this parameter decimals Valid range Defines the maximum and minimum for a write parameter If a user tries to enter a value outside the range a warning message will appear If used in combination with scaling it is the scaled value that should be used 10 Click on the save button in order to add the new parameter to the Template Cancel will close the window and discard all changes 11 Repeat step 8 to 10 until all parameters for the device is added to the Template 12 Click on the Clone link on the line of the parameter it will be duplicated then by clicking the Edit link it can be modified This may save time in the construction of the Template netbiter 4a Netbiter Argos AS User Manual 4a Rev 1 00 7 2 Upload Template On th
15. config uratio Nessie ennen 17 Advanced Connie urato esneme ae n E E E E EA 17 Connect Device Profiles esis tesceseccnsrensectsadeasinediae sda ecedevoc EEES 17 SENEE e T aa E E E E E E E E EE 18 ONNE Ar ee A EE E E E A 18 Positioning the remote SVSUONMI iss ses tcscneictbcceei covaiunardeananddancasesavtenwed couvadderseatauadadanevivesenteeds 18 create a DasnDOal O9 sinceri ieie E a E 20 WCD EOD M Ea E EE E E EEA canes 20 Prone Dashboard Soeren E E N EEE E EE 20 DRDO WAPO OS ae EEE E EE EE E 21 Wda ee A E E 21 AOW OE aaa A E A T A E ceens 22 REMOVE WIEC E aranna E EEA EEEE EA EEA 22 REANA WODO inene E A ees 22 HMS Industrial Networks AB Page 3 51 44 AmS I 3 4 4 3 4 5 3 4 6 4 Subscriptions 4 1 1 4 1 2 5 1 List view 5 2 Project view 5 3 Add a new user Di Sud 5 3 2 5 3 3 5 4 Edit a user 5 4 1 5 5 Lost password 6 Profiles 6 1 Device Profile 6 1 1 6 1 2 6 1 3 6 1 4 6 2 Global profiles 7 1 Create a new Modbus device template 7 2 Upload Template 7 3 Edit 7 3 1 7 3 2 7 3 3 7 4 Export Template 8 HMS Support netbiter Value List widget Drawing widget Create a Drawing Add Subscription key Assign a Subscription key User information Alarm scheduling Changing password Create a Device Profile Edit Device Profile Copy Device Profile Remove Device Profile HMS Industrial Networks AB Netbiter Argos User Manual Rev 1 00 Page 4 51 4a Netbiter Argos ANS User Manual
16. done after the offset is added Examples A register value of 5 and an offset of 2 gt 3 will be shown on the page HMS Industrial Networks AB Page 46 51 4a Netbiter Argos AS User Manual 44 Rev 1 00 Mask Is used to mask out specific bits from the Modbus register on the page the value is presented in binary The Modbus register will be masked logic and and shifted to the right before the value is presented on the page logged or compared with for alarm Examples Modbus register value 214 D6 hex Mask 240 FO hex gt 208 DO hex gt the value is bit shifted and will be shown on page as 13 D hex To enter a hex value use Ox as a prefix D6 hex gt OxD6 Presentation Defines how a value will be represented on a page Following presentation can be set e Show as value Show as value will read from the address and present the result at the page e Read Write value Read Write reads the value from the address and present it There will be a set button next to the value at the page which makes it possible to write to the address e Write only This value can only be written and not be read e Show with enumeration Show with enumeration will read the value from the address and present it with the corresponding enum string see Enum e Read Write value with enumeration Read Write value with enumeration will read the value from the address and present it with the corresponding enum string There will
17. for the dashboard can be changed by pressing the edit button Dashboard properties Dashboard name Dashboard Access level User Sort priority 50 Connected to MyFirstSystem edit Dashboard properties Dashboard name Dashboard Access level User Sort priority 50 Ok Cancel Dashboard name The Name of the Dashboard which will be displayed in the menu Access level Determines who will have rights to access the dashboard only the Admin or also the users Sort priority Determines the order of the dashboards Lowest value will be placed farthest to the right Possible to set from 1 to 99 Press the OK button in order to save the new properties 3 4 Widgets The widgets are building blocks used to building up the dashboard The available widgets are e Live values o Value List widget o Drawing widget e Logged values o Latest logged widget o Log Graph widget e Alarms o Alarm List widget HMS Industrial Networks AB Page 21 51 netbiter 4a Netbiter Argos AS 4a User Manual Rev 1 00 3 4 1 Add widgets 1 Go to the the dashboard the new widget is intended to be placed in 2 Click on the Widget in the Widgets menu on the right side it will be added as a block on the right side f Status Configuration Dashboards Map Backup Firmware Mobile network Properties System picture drawing edit delete Dashboard properties Dashboard name Dashboard A
18. onto the drawing By clicking on the image in your Image library and then click OK in the lower right corner the image will be added to your drawing By double click on image the properties window will appear properties x position 272 97 opacity 1 parameter OP x Close position The position of the object on the drawing size The size of the object Opacity Determines the transparency of the text from O to 1 were 1 is solid parameter Connect the image to a parameter If a parameter is connected to the image the image can change depending on the parameter value Properties x J position size opacity 1 parameter Digital input 1 T O Default Inknown 0006 O T Default The default image that will be displayed The image can be changed by double click on the image icon the Image library will appear Unknown If the parameter is unknown cannot be read the unknown image will be displayed on the drawing The image can be changed by double click on the small question icon the Image library will appear Value Determines the image that will be displayed on the drawing if the set condition is fulfilled value Q value lt ie value gt 7 ae If parameter value is Equal to lt Smaller lt Smaller or Equal to gt Larger gt Larger or Equal to than the set value the default image will be changed to the image displayed as an icon next to the conditio
19. represent a summary alarm This will show the current system alarm with the highest severity You can also specify an alarm to show from a list of configured alarms for the system Alarms are color coded based upon the severity The absence of active alarms will be displayed as green 7A Connection Allows you to connect items on your drawing to show relationships between them Connectors can be repositioned by clicking and dragging on their end nodes End nodes will automatically attach to any other nearby end nodes allowing you to drag connections without having to reconnect them You can also assign a system parameter to a connection which will cause it to perform like a gate opening when the parameter is one value and closing when it is another e Draw rectangle Can be positioned and styled to match your needs Draw ellipse Can be positioned and styled to match your needs Draw line Can be positioned and styled to match your needs Delete ON O Removes the selected item from the drawing Snap to grid Turn on off snap to grid and determine the grid size As default off netbiter Netbiter Argos 44 AIS User Manual 4a Rev 1 00 Drawing Settings Change the name of the drawing and the height of the drawing area D Copy object Copy an existing object on the drawing gf Send to back All objects on the Drawing are on their own layer by clicking the send to back button it will move the object f
20. 00 EE E 6 64S After selecting color press OK Opacity Determines the transparency of the text from 0 to 1 were 1 is solid text The text displayed on the drawing font The text font for the object font pt The text size b E Makes the text bold or and italics E i Determines the text position within the tool left center or right positioning 3 4 6 2 Dynamic Label When a Dynamic label is added to the drawing open the properties window Fill in the preferred properties the change will be done directly When finished press the close button or move to another drawing tool link to param properties x position 181 63 size 106x22 color opacity 1 text link to param font Arial 2 font pt 14 bl JE Ea parameter F O Close position The position of the object on the drawing size The size of the object color The text color can be set by clicking the colored rectangle S068 i After selecting color press OK opacity Determines the transparency of the text from O0 to 1 were 1 is solid text The text displayed on the drawing When a parameter is added the default formation is lt parameter label gt SvalS where SvalS is the parameter value THE SvalS part can be placed anywhere within the string font The text font for the ogject HMS Industrial Networks AB Page 26 51 netbiter 4a Netbiter Argos AAS User Manual 44 Rev 1 00 font pt The text size for the o
21. GPS gps Enable GPS tracking on map disabled z Alarm radius soo m save clear tracking Latitude Manual setting for the Latitude position WGS 84 netbiter 4a Netbiter Argos ATIS User Manual J4 Rev 1 00 Longitude Manual setting for the Longitude position WGS 84 Get position from If a GPS is connected to the System the osition GPS can manually be retrieved by pressing the GPS button Enable GPS tracking Enables the Tracking function need to have a on map GPS receiver connected in order for this function to work Alarm radius The Alarm radius is used for setting the boundaries for the Geo Fencing function this function need an GPS receiver connected The manual positioning service works without any GPS receiver Note If connected to a GPS the device can automatically position itself on the map GPS tracking on the map can be enabled to monitor movements of the device An alarm can be triggered if the device is moved outside of the defined radius also known as Geo fencing netbiter User Manual Rev 1 00 4a Netbiter Argos AANS 4a 3 Create a Dashboards The dashboard is used to making a customized presentation page for the system There are two different types of Dashboards e System Dashboard A Dashboard made for a single system e Profile Dashboard A Dashboard that can be used for multiple Systems using the Profile it is assigned to 3 1 System Dashboards E Click c on n the eee ta
22. T u6R Standard subscription 12 month valid for 1 system s 0 1 2012 01 19 Use Free subscription Use Free subscription 1 3 Subscription key The subscription key for this row Order ref The order reference entered when the subscription key was bought Information Describes what is included in this subscription key i e period number of system that is valid for this key Used Number of used keys total number of keys which will show how many subscription that is available for this key netbiter 4a Netbiter Argos Haas User Manual 44 Rev 1 00 Add date The date when the key were activated Select Click this to mark that this subscription key will be used to deploy it to a Remote system 4 1 2 Assign a Subscription key 1 Select a subscription key to use click Select for the preferred Subscription key 2 Mark the check box for the Remote systems that will have the subscription deployed to it 3 Click the use subscription key button to deploy the key to the selected Remote systems Subscription key Order ref Information Used Add date Select 85y Y8y p3T u6R Standard subscription 12 month valid for 1 system s 0 1 2012 01 19 1 e Use Free subscription Use Free subscription 1 3 a subscrintion kev 3 Deanov System subscription overview 5 Name Device ID Project Level Activated Expiration date Select Netbiter System 353234023061169 MyFirstProject Free Yes FF Subpscrip
23. arthest back This can result in that another object can be placed in front of it a Send to front j All objects on the Drawing are on their own layer by clicking the send to front button it will move the object to the front This can result in that another object can be placed behind of it 3 4 6 Create a Drawing The Label Image component and alarm objects are added to the drawing by selecting the preferred object and then click on the drawing the dray and connection objects are added by pressing down the left mouse button and then move the mouse when the object has the preferred size let go of the mouse button The objects in the drawing tool are edited on their individual properties window which is accessed by double clicking on the object When the Property window is open it is just to click on another object in order to see its properties 3 4 6 1 Static Label When a Static label is added to the drawing open the properties window Fill in the preferred properties the change will be done directly When finished press the close button or move to another drawing tool Netbiter Argos properties x position 129 56 size 114x22 color ha opacity 1 text Netbiter Argos font Arial x font pt 14 6 G E EE close position The position of the tool on the drawing size The size of the tool color The text color can be set by clicking the colored rectangle netbiter 4a Netbiter Argos AIS User Manual 4d Rev 1
24. b under the Management menu for the System 2 Click the add button under the Dashboard tab Status Configuration Dashboards Map Hackiup Finnerare Merbile anor P T panies 3 A new dashboard for the system is created and ready to be configured see section 3 4 3 2 Profile Dashboards 1 Click on the All dashboards menu under the Management menu 2 Click on the Add dashboard tab 3 Fillin ill in the inforr information on the Add dashboard screen and then U the save button i 9X A Projects Alls is Templates Profiles All dashboards Logged In Victor Hanss Account N r Profile dashboards System dashboards Add dashboard Dashboard name Access level Admin Sort priority so Dashboard type System Profile System Netbiter System TE save Dashboard The Name of the Dashboard which will be displayed in the menue name Access level Determines how will have rights to access the dashboard only the Admin or also the users netbiter 4a Netbiter Argos ASG User Manual 4d Rev 1 00 Sort priority Determines the order of the dashboards if there are several Lowest value will be displayed first Possible to set from 1 to 99 Dashboard type Determines if it is a System or Profile dashboard Profile Determines to what Profile the dashboard should be connected towards The Profile need to be created before a device can be added 3 3 Dashboard properties The properties
25. biter 44 AmS I Table of content 1 1 1 2 1 3 1 3 1 1 3 2 1 3 3 2 1 2 1 1 2 1 2 2 1 3 2 2 2 3 2 4 2 5 2 5 1 2 5 2 2 6 2 2 7 1 2 8 2 8 1 2 9 3 3 1 3 2 3 3 3 4 3 4 1 3 4 2 3 4 3 netbiter Netbiter Argos User Manual Rev 1 00 Getting started ere stiresse sc teases acca nn tesnesesanceavarcadeuno meses sueotecnscacsacaansrendeneeess 5 Create a Netbiter Argos ACCOUNL cccccsecccssscccessececeececeesceceeeceeeaeceseucesseecesenecessuncessenees 5 POC es TC SVG EON E E E E 7 PACTIN GUI Ss SY SU CIM eee aE E E pasta renensanasaseauapenoiauaeaenectianss 8 PSST CUO a areca E cties ok So enced ooleoa Gated as easter E E O R 8 OS C22 Oia ahoetsancetteacgcatn cc cadauebosessgansent E E not ieacaaatuccbcetauchesenses 9 TST Te GD ssi rete E A E E E E 9 Basic Configure of the Netbiter System ccscsccscsccccccscsccccccscsceccccscscescccecncecescess 11 Ee ekeke ne A A E O A E A E A E E 11 Moapu u s CVI CE sasn E E E E E R 11 NAN OC O n E E E ES 12 NCUA Gl o OVIE oa a E E E 12 Add log paramete serie spassces ae erae ne saciessce aeteara powarnei aces E E EOE 12 Add VISUALIZATION parameter aa sceccacssasiviatasuscaesniwcensasdinasabacavinanepiusceosniedenshdesvabasaninaerucceesse 13 Add alarmi parameter sncdscsacer ici sea n nea E 15 Gateway Settings ssssscseiiriisennecnee riedna rnae e r SEa rE EERTE EE AA EADE 16 OP eee soe ec E E T 16 MOODUS oo E E EE E E aeeneeenesasers ceceeus 16 Synchronize the
26. bject ib E Makes the text bold or and italics E Elja Determines the text position within the object left center or right positioning 3 4 6 3 Image When the image is added the open image from server will appear pen inagpe irom sirier O My Images Pubbe Library drag from here Space left 10 00 Mb The right side contains the Netbiter Image library and the left your Image library Images displayed on the drawing must be located on your Image library Adding Images to your Image library can be done in two ways 1 From Netbiter Image library By choosing an image in the Netbiter Image library and click on it you will see a preview of the image and by clicking the green arrow below the image will be moved to your library Public Library drag from here People a users4 png amp security_agent pna g woman png Space left 10 00 Mb ab businesswoman png p amp businesswoman2 png 2 user2 png a woman2 png o businessman png ri amp aenius ona 2 Upload from your Computer By clicking on the image icon a file transfer window will appear that allow you to browse your computer and decide what image you like to upload to your Image library Supported formats are jpeg gif png L Public Library Space left 10 00 Mb Li o5 netbiter 4a Netbiter Argos ASG User Manual 4d Rev 1 00 When the image is located on your Image library it can be chosen to be added
27. ccess level User Sort priority Connected to MyFirstSystem edit ws ce Live values Add Value List dd Drawing H Logged values Alarms 3 Assoon as the widget is added the dashboard is automatic saved 3 4 2 Remove widget 1 Click on the delete button on the widget in order to remove it System picture drawing edit delete 3 4 3 Rearrange widgets The order of the widgets can be rearranged by dragging and dropping them in the preferred order 3 4 4 Value List widget 1 Click the edit button on the Live value list widget and the Settings window will apear Settings Title Live values add Title The Name of the widget which will be displayed in the dashboard 2 Enter the title of the widget netbiter 44 AmS A 3 Click the add button Netbiter Argos User Manual Rev 1 00 4 Select a parameter that will be displayed on the dashboard by clicking on it It is parameters that are configured as vizualisation or log parameter that are possible to choose from see section 2 in order to add new Select parameter Current selected Type Device profile Select parameter 4 0 MyFirstSystem gatewa 4 System new Ok Cancel 5 Click OK and the Widget will be configured Cancel will close the window and discard all changes 3 4 5 Drawing widget The drawing tool is a graphical web application that can be used to create dynamic customized
28. cheduling netbiter 4a Netbiter Argos AS User Manual 44 Rev 1 00 5 3 1 User information In order to add a new user information need to be filled in Information marked with is required Username Password Repeat password Fest name Last name Company Phone no Mobde Coll E mad Address ZIP Post code City State County Country Language Tene zone Override the remote system tme fore Additional information 5 3 2 Add user Engbsh Europe Stockholm No le User rights Under User rights the access that the user has for Projects in the Account is setup Users information Project name MyFirstProject save delete Project access Read data Write data Ack alarms Alarms Offline alarms GPS alarm Alarm via SMS netbit r User rights Alarm schedule Determines if the user has access to the project Determines if the user have access to read data from the system Determines if the user have access to write data to the system Determines if the user have access to acknowledge alarms Determines if the user have access to receive alarms Determines if the user have access to receive Offline alarms need to have Alarm access in order to receive this alarms Determines if the user have access to receive GPS alarms need to have Alarm premises in order to receive this alarms Determines if the user have access to rece
29. d system under the All systems menu Enter the System name Enter the Device ID and Activation code for the Netbiter gateway The Device ID and the Activation Code are provided on the Netbiter Argos information note supplied with the Netbiter gateway Set to which Project the system should be placed in Sett the correct Time zone where the system will be installed Click the add button in order to add a system Management Projects All systems Templates Profiles All dashboards Logged In Victor Hansson System name Device ID Activation code Project Time zone add System name Device ID Activation code Project Time zone netbit r Account Netbiter_Argos 5 Add system pe od Active Inactive Add system MyFirstProject z Europe Stockholm The name of the System which it will be referred to on Netbiter Argos The identification number for the gateway supplied with the gateway The password for activating the gateway supplied with the gateway The Project that the system should be connected to The time zone that the system is located in HMS Industrial Networks AB Page 7 51 4a Netbiter Argos HAMS User Manual 4a Rev 1 00 e e 1 3 Activating a system Presentation Reports Account Contact Logout i Projects All systems Templates Profiles All dashboards Logged in Victor Hansson Account Netbiter_Argo
30. e APN password 10 Click the send button in order to send down the Mobile network settings to the Netbiter EC250 netbiter 4a Netbiter Argos ANS User Manual 44 Rev 1 00 2 Basic Configure of the Netbiter System To start the configuration go to the Management menu and then to the System that is going to be configured and click on the Configuration tab Presentation Reports Projects All systems Templates Profiles All dashboards _ogged In Victor Hansson ICIO anlss Account Netbiter_Argos A Manaat rant acts hMiyFirstF act Cirect ste Lonfiauration ay Status Configuration Dashboards Map Backup Firmware Mobile network Properties A 2 1 Add device A device is a unit that can be connected to the Netbiter gateway with for example Modbus and together with the Netbiter gateway form a Netbiter System 1 Click on the add device button under the Device configuration tab Device configuration Logging Visualization Alarms Gateway settings Show Advanced Config Device Device type Settings Template Action MyFirstSystem gateway Virtual a Netbiter EasyConnect EC220 Edit 2 1 1 Modbus device 2 Chose Modbus in the dropdown menu for the Device type 3 Chose the Template for the device from the dropdown menu 4 Chose the Device name that the device will be referred to as in the Netbiter Argos account 5 Enter the Modbus Slave ID for the Modbus device 6 Ifa Modbus TCP device is u
31. e Netbiter Argos Support web page www support netbiter com there are a wide range of premade Templates to be downloaded They are accessed by clicking on the Device Template button Tem ates for Device Templates WTO Example of template categories e Genset e O nodes e Energy meters e Power monitoring e UPS e PLC e etc 1 Click on the Templates menu under the Management menu 2 Click the upload template button eres Management eet Projects All systems Templates Profiles All dashboards gge LOYE Device templates 3 Click on the Browse button and choose the Template file that is about to be uploaded Upload template from file File name Bl ddra upload template cancel 4 Click on the upload template button netbiter 4a Netbiter Argos AS User Manual 44 Rev 1 00 7 3 Edit 5 oe Device templates E Test Template El Test Group C Test Parameter T Add paramet D Add group add templat upload templat 7 3 1 Template 1 Click on the Edit link on the line of the Template that is going to be edit Edit template Template type Modbus Name Test Template save cancel 2 Change the Name 3 Click on the save button 7 3 2 Group 1 Click on the Edit link on the line of the Group that is going to be edit 2 Change the Name Edit group Name Test Group save l cancel 3 Click on the save button 7 3 3 Paramet
32. e value e 16 bit value 16 bit positive value e 32 bits value with sign 32 bit value with sign Most significant word register on low address modbus reg i i 1 Int32 e 32 bit value 32 bit positive value Most significant word register on low address modbus reg i i 1 l Int32 e Swapped 32 bits value with sign 32 bit value with sign Most significant word register on high address modbus reg i 1 l Int32 s HMS Industrial Networks AB Page 45 51 44 1A Scaling Offset netbiter Netbiter Argos User Manual Rev 1 00 e Swapped 32 bit value 32 bit positive value Most significant word register on high address modbus reg i nt32 e e Floating point 32 bit floating point IEEE 754 Most significant word register on low address modbus reg i 1 i Float e Swapped floating point 32 bit floating point IEEE 754 Most significant word register on high address modbus reg i i 1 Float s e Double precision floating point 64 bit floating point IEEE 754 Most significant word register on low address Mochi fey 1 i Double IMSE 2 3 2 E T QLS e Swapped double precision floating point 64 bit floating point IEEE 754 Most significant word register on high address Mohs fey 1 i Double s T LES 4 j a 4 MSE 2 e Hi 8 bits value with sign Show the high byte of a 16 bit register with sign When writing this value it will read t
33. emplates Profiles All dashboards t Device templates El Test Template ghf add template upload template 6 Enter a Name for the group l Add group Name save cancel 7 Click on the save button netbiter 4a FITTS Mf Netbiter Argos User Manual Rev 1 00 8 Click on the Add parameter link in order to add a new parameter to the template Templates Profiles All dashboards Device templates El Test Template est group 1 Add parameter T Add group add template uploa d template 9 Fill inthe information on the Add parameter screen Add parameter Name Unit Type Holding Fi Address 0 Datatype 16 bit value Scaling 1 Offset 0 Group Test group Presentation Show as value x Enumeration 102 Number of decimals Mask Disable mask Ox Valid range l save cancel Name Unit Register Type Address Datatype netbiter The name for this parameter The Unit for the parameter Defines the Modbus register type Holding Input Coil Discrete input To set Read or Write for this address see Presentation The Modbus register address to Read Write To enter a hex value use Ox as a prefix D6 hex gt OxD6 Defines the datatype of the Modbus register s Can be one of the following e 16 bits value with sign 16 bit positive or negativ
34. er 1 Click on the Edit link on the line of the Parameter that is going to be edit 2 The Edit parameter screen will appear se section 7 1 step 9 for further information Holding E E EE Show as value sable mask ox TTT 3 Click on the save button after the parameter is edited netbiter 4a Netbiter Argos AIS User Manual 44 Rev 1 00 7 4 Export Template 1 Click on the Export link on the line of the Template that is going to be exported Y cer add template upload template 2 Click on the yes button in order to proceed with the export Export template to file Are you sure you want export the template Test Template The exported template can be used for upload to another account aca nam 3 Click on the Test Template xml link it will be the name of the Template Export template to file 100 completed v Template generated Right click k to save the template file 4 The look of this screen will be different depending on the web browser choose if you like to open the file or save it to the hard drive of your computer Du har valt att 6ppna Test Template xml som ar en fil av typen XML Document fran https www netbiter net Vad vill du att Firefox gor med denna fil Wi Spara fil G r detta automatiskt f r denna filtyp i forts ttningen a 5 Click the OK button
35. he 16 bit register mask it with this value and write it back e Lo 8 bits value with sign Show the low byte of a 16 bit register with sign When writing this value it will read the 16 bit register mask it with this value and write it back e Hi 8 bits value Show the high byte of a 16 bit register When writing this value it will read the 16 bit register mask it with this value and write it back e Lo 8 bits value Show the low byte of a 16 bit register When writing this value it will read the 16 bit register mask it with this value and write it back The Modbus register value will be divided by the scale value before presented on the page or multiplied before value is written to a slave device Examples Modbus register value 510 Scale value 10 gt 51 0 will be viewed on page Modbus register value 5118 Scale value 100 gt 51 18 will be viewed on page Modbus register value 1 Scale value 0 1 gt 10 will be viewed on page Modbus register value 2 Scale value 1 gt 2 will be viewed on page Page input 127 5 Scale value 10 gt 1275 will be written to Modbus register The Modbus register value will be subtracted with the offset value before it is presented on the page logged or compared with for alarm If scaling is also in use it is done before the offset is subtracted The Offset value will be added to the value before value is written to a Modbus slave device If scaling is also in use it is
36. he left mouse button on the start corner and let it go where the opposite corner of the rectangle should end Ones the rectangle is added the size can be change by grabbing the edges of the rectangle and drag it By double click on the added rectangle a properties window will appear properties x position size 114x78 color i opacity 1 radius 0 gradient W linear position The position of the object on the drawing HMS Industrial Networks AB Page 32 51 netbiter 4a Netbiter Argos AIS User Manual J4 Rev 1 00 size The size of the object color The text color can be set by clicking the colored rectangle fe E 6 6B After selecting color press OK Opacity Determines the transparency of the text from O0 to 1 were 1 is solid radius Determines the radius of the corners gradient Makes the object gradient 3 4 6 8 Draw Ellipse In order to add an ellipse click on the draw ellipse tool and press the left mouse button on the start corner and let it go where the opposite corner of the rectangle should end Once the ellipse is added the size can be change by grabbing the edges of the rectangle and drag it By double click on the added ellipse a properties window will appear properties x El position 32 477 size 502x178 color i opacity 1 i aradient IC linear ICI radial position The position of the object on the drawing size The size of the object color The text colo
37. ion expired E SUDSCTIPDON iess Nan 3 month b1 sUDScripton more Man monin netbiter 4a Netbiter Argos ASG User Manual 4d Rev 1 00 5 Users 5 1 List view All available users for the account are listed under Account gt Users gt All users 5 2 Project view The users that have access to a specific project can be viewed under Account gt Users gt Users by project Showing 1 to 2 of 2 entries Full name raii om s Alarms MyFirstProject Victor Hansson admin v 7 d v Aa ms Project access Determines if the user has access to the project Read data Determines if the user have access to read data from the system Write data Determines if the user have access to write data to the system Ack alarms Determines if the user have access to acknowledge alarms Alarms Determines if the user have access to receive alarms Offline alarms Determines if the user have access to receive Offline alarms need to have Alarm access in order to receive this alarms GPS alarm Determines if the user have access to receive GPS alarms need to have Alarm premises in order to receive this alarms Alarm via SMS Determines if the user have access to receive alarms via SMS v Means that the user has access a Means that the user has no access J Means that the function is not available 5 3 Add a new user Adding new users is done under Account gt Users gt Add user It consists of three parts e User information e Access level e Alarm S
38. ion is to download the configuration to the Gateway 1 Press the button synchronize configuration synchronize configuration 2 The Gateway will reboot and reconnect to Netbiter Argos automatically Note This may take a few minutes Synchronize configuration A Synchronize of contiguration in progres Do hot tut back or dose the browser until the pee mpk j 2 7 Advanced configuration The Advanced configuration menu is accessed by click on the Show Advanced Config Link under the Configuration tab Device configuration Logging Visualization Alarms Gateway settings Device Device type Settings Template MyFirstSystem gateway Virtual Netbiter EasyConnect EC220 Edit 2 7 1 Connect Device Profiles The advanced configuration allows you to assign Device Profiles to the System 1 Click the connect device profile button under the Connect device profile tab Device configuration Logging Visualization Alarms Connected device profile Gateway settings Hide Advanced Config Device Device type Device profile Action 2 Chose the Device you have added to your system to which you like to add a device profile 3 Chose the Profile you like to add to the device Connect device profile Device MyFirstSystem gateway Device profile EC220 Starterkit Temperature save cancel Device Is the Device that is connected to the gateway and which the Device Profile should be connected towards
39. irtual GPS type is used when the Profile is being created for a GPS receiver c Modbus type is used when the Profile is being created for a Modbus device netbiter Netbiter Argos 44 AIS User Manual 4a 6 1 2 7 Rev 1 00 Choose the template to be used by the profile See section 7 for information about how to create or upload a device Profile Click on the save button to proceed The Edit profile screen will appear Presentation eene Management f Projects All systems Templates Profiles All dashboards Logged In Victor Hanss Edit profile Profile name Test Profile save Connected templates 1 Netbiter EasyConnect EC220 Remove Device profile in use by Logging Visualization Alarms System name Project Sync Profile currently not in use by any system Click on the add button in order to connect additional Templates to the Device Profile To add Logging Visualization amp Alarm to the Device Profile se section 2 2 2 3 and 0 The Device profile is automatically saved during the configuration Edit Device Profile Click on the Profiles tab under the Management menu Click on the Edit link on the row of the Device Template that should be edited User defined device profiles l Profile type Profile name Virtual Test Profile Copy Remove The Edit profile screen will appear Change the Profile name by edit the existing name and then click the save button
40. ive alarms via SMS HMS Industrial Networks AB Page 38 51 44 Mf 5 3 3 Alarm scheduling Netbiter Argos User Manual Rev 1 00 This section makes it possible to decide when the user will get e mail or SMS This is done to make selection in the schedule one for e mail and one for SMS The schedule can be marked in periods of 30 minutes using the mouse Areas marked with green colors will send messages periods with grey color indicates times when no message is send Click the mouse on the schedule to change the color If you click the mouse button and drag the pointer the schedule can be painted Under the schedule there is a selection to override the settings If set to anything but N A all messages with this severity set or higher will be sent despite the scheduled time Users information User rights Alarm schedule z Alarm schedule controls when the user gets alarms sent via SMS and E mail Note that the settings must also be enabled for the project for the user to get the alarm E mail schedule Mon Tue Wed Thu Fri Sat Sun 00 00 02 00 04 00 06 00 08 00 10 00 12 00 14 00 16 00 18 00 20 00 22 00 Ignore Schedule for alarms with severity N A or higher save delete 5 4 Edit a user In order to edit an existing user Ignore Schedule for alarms with severity N A SMS schedule Mon Tue Wed Thu Fri Sat Sun 00 00 02 00 04 00 06 00 08 00 10 00 12 00 14 00 16
41. larm As default Summary and if chooses set to a specific alarm In order to choose a specific alarm that should be indicated click on the F button on the properties window and all configured alarms will be listed Click on the alarm that should be assigned and then click the OK button 3 4 6 6 Connections In order to add a Connection click on the connection tool and press the left mouse button on the start and let it go where the connection should end Once the Connection is added the start and end can be moved by dragging the end points If there are two or more connections the end points can be connected by dragging them together By double click on the Connection a properties window will appear netbiter 4a Netbiter Argos AS User Manual J4 Rev 1 00 properties x position size parameter position size Opacity parameter properties The position of the component on the drawing The size of the component Determines the transparency of the text from O0 to 1 were 1 is solid The Parameter connected to the Connection position Size O parameter Digital input 1 open if Close By clicking on the F button on the properties window a parameter can be assigned to the Connection The open if parameter determines the condition that must be met in order for the connection should open Closed Open 3 4 6 7 Draw Rectangle In order to add a rectangle click on the Draw Rectangle tool and press t
42. link will be sent to the e mail address provided in the account information Open the e mail received from Netbiter Argos in your e mail client and click on the activation link Check Your E mail Your account has been created However Netbiter Argos requires account activation An activation link has been sent to the e mail address you provided You cannot use this account Unti you visit the link provided in the e mail Please check your e mail for further information Make sure you add the domain nethiter net in the white list of your spam Sener if you shouldn t recerve the email go to login 7 Now itis possible to login to the account Press the go to login button to go back to the Netbiter Argos login page Your account is now activated and ready to use Click on the button below to go to the login page go to login 8 Navigate to the Netbiter Argos login page https www netbiter net Enter the User and Password for the account and then click the Log on button in order to login to the Netbiter Argos account Online management portal User Password Create an account Lost your password 9 When logged in the Gateway used for creating the account need to be activated see section 1 3 netbiter 4a MANS AA 1 2 Netbiter Argos User Manual Rev 1 00 Add a new System Adding new Systems to a Netbiter Argos Account is done under the Management tab 1 Click Ad
43. n The image can be changed by double click on the icon the Image library will appear netbiter 4a Netbiter Argos ASG User Manual 44 Rev 1 00 When a writable parameter is connected to the image and the writable checkbox is set the on click set value to value will be written to the parameter connected to the image properties x PE ee position 272 97 size 256 x 256 opacity 1 parameter Relay output oP x writable W on click set value to Default w amp Unknown Gy value v value v 9 value v 9 Close te If you want to delete the Image this is done by clicking on the image in your Image library and the click on the delete button My Images af users4 png Space left 9 94 Mb 3 4 6 4 Component When the Component is added the add drawing from server will appear add drawing from server tL My Drawings LJ Public Library Ok Cancel netbiter 4a FITTS Mf Netbiter Argos User Manual Rev 1 00 Under the Public Library on the right there is a set of pre made Components that can be added to the drawing When a component is clicked it will be previewed in the middle window gt Public Library gauge E white E eyeGauge E blue yellow In order to add the Component click the OK button in the bottom left corner By double click on image the properties window will appear
44. r can be set by clicking the colored rectangle nw a E G gt B B gt 8B E 06 6B After selecting color press OK Opacity Determines the transparency of the text from O0 to 1 were 1 is solid gradient Makes the object gradient Oe netbiter 4a Netbiter Argos AS User Manual 4d Rev 1 00 3 4 6 9 Draw line In order to draw a line click on the draw line tool and press the left mouse button on the start of the line and let it go where the line should end Once the line is added the size cannot be changed By double click on the added line a properties window will appear aaa x position 352 115 size 257 x 11 color mai opacity 1 gradient Close position The position of the object on the drawing size The size of the object color The text color can be set by clicking the colored rectangle a Ee EB BEE After selecting color press OK opacity Determines the transparency of the text from O to 1 were 1 is solid radius Determines the radius of the corners gradient Makes the object gradient 3 4 6 10 Delete object By clicking on an object in the drawing and then the Delete object tool it will be removed from the drawing netbiter 4a Netbiter Argos AS User Manual 44 Rev 1 00 4 Subscriptions Subscriptions are managed under Account gt Licensing gt Subscription All Subscription key added to the account are listed with information about the le
45. r parameters that are of enumeration type in the template the enumeration can be overridden by clicking the checkbox at the right of the row The parameter value can be a presented with the string definition for a value were the values are separated by Ex 1 ON O OFF 3 Click Save and the visualization parameter will be added Cancel will close the window and discard all changes netbiter 4a Netbiter Argos AS User Manual 1A Rev 1 00 2 4 Add alarm parameter The remote system can be configured to generate alarms when certain conditions are met 1 Click the add alarm parameter button under the Alarms tab Device configuration Logging Visualization Gateway settings Show Advanced Config Current configuration has 0 alarms Device Device profile Group Parameter Description Trigger Severity Action add alarm parameter 2 Fill in the information on the Add alarm setting screen Add alarm setting Device MyFirstsystem gateway bd Group I O IT Parameter Analog input 1 0 10V ICE Description Trigger Equalto iS Value 1 Scaling 1 Offset 0 Class Class 1 Severity Indeterminate save cancel Device The device that the parameter comes from Group The template Group that the parameter comes from Parameter The visualization parameter that is being added Description Will be the name of the alarm By clicking the
46. rmation should be supplied with the SIM card if not please contact your mobile operator If an APN username and password is needed fill in that information I have a Netbiter SIM card 2 I have a custom or standard SIM card SIM card mobile number APN 2 APN username APN password 1 3 3 Netbiter EC250 6 Click the activate button in order to activate the Netbiter EC250 System If the Netbiter EC250 is connecting using GPRS Mobile network settings are needed 1 3 3 1 Netbiter SIM card 7 Enter the SIM card mobile number for the Netbiter SIM that was provided in the SIM card envelope I have a Netbiter SIM card I have a custom or standard SIM card 2 SIM card mobile number 8 Click the send button in order to send down the Mobile network settings to the Netbiter EC250 netbiter Netbiter Argos 44 AIS User Manual 4a Rev 1 00 1 3 3 2 Custom or Standard SIM card 7 Make sure that the have a custom or standard SIM card option is chosen 8 Enter the SIM card mobile number for the SIM card This information should be supplied with the SIM card if not please contact your mobile operator 9 Enter the APN for the SIM card This information should be supplied with the SIM card if not please contact your mobile operator If an APN username and password is needed fill in that information I have a Netbiter SIM card 2 I have a custom or standard SIM card SIM card mobile number a APN 2 APN usernam
47. s anagement All systems Inactive Pp oe Active inactive _ Add system i Search Showing i to 1 of i entries Name Device ID Project a Level e GPS c L P ON Netbiter System 353234023061169 MyFirstProject Standard No Showing 1 to 1 of 1 entries 1 Click on the Management menu i Click on the All systems menu 3 Click on the Inactive tab 4 Choose a STANDARD Subscription for the system in the dropdown window 5 This step is optional By clicking the add subscription key button a Subscription key can be entered and added in the select subscription window Enter subscnption key activate cancel 1 3 1 Netbiter EC150 6 Click on the activate button in order to activate the Netbiter EC150 System netbiter Netbiter Argos 44 AIS User Manual 4a Rev 1 00 1 3 2 Netbiter EC220 1 3 2 1 Netbiter SIM card 6 Make sure that the I have a Netbiter SIM card option is chosen 7 Enter the SIM card mobile number for the Netbiter SIM that was provided in the SIM card envelope I have a Netbiter SIM card I have a custom or standard SIM card 2 SIM card mobile number 1 3 2 2 Custom or Standard SIM card 6 Make sure that the I have a custom or standard SIM card option is chosen 7 Enter the SIM card mobile number for the SIM card This information should be supplied with the SIM card if not please contact your mobile operator 8 Enter the APN for the SIM card This info
48. sed enter the Modbus IP number for the device Add device Device type Modbus x d Template ES Device name Modbus slave Modbus IP Modbus port 502 save cancel Device type The type of device that will be added Template The Device template used for this Remote device see section 4 Device name The name that the device will be referred to as Modbus slave The Modbus Slave ID for the device netbiter 4a Netbiter Argos AS User Manual 44 Rev 1 00 Modbus IP If it isa Modbus TCP device add the IP number for the device Modbus port The port that the gateway will use for communication with Modbus TCP 2 1 2 Virtual device A virtual device is the Netbiter gateway itself and is pre loaded when the gateway is activated 2 1 3 Virtual GPS device In order to connect a GPS receiver to the System it needs to be added as a Virtual GPS Further settings is required see section 2 5 2 2 Add log parameter Added log parameters can be displayed under the Historical data tab for the System presentation page or on a Dashboard It will take up to an hour before the first logged data is sent up to the server automatically 1 Click on the add log parameter button under the Logging tab Device configuration Visualization Alarms Gateway settings Show Advanced Config With current configuration log will be saved for 750 days System has subscription level Free Average data is saved for 750 days with 25
49. ter Argos AS User Manual 4d Rev 1 00 3 Clicking Save button and the alarm parameter will be added Cancel will close the window and discard all changes 2 5 Gateway settings Under the Gateway settings the GPS and Modbus communication can be configured Only one variable can be set at the time there for the set button next to the variable have to be pushed before moving to the next If set is not pushed the Gateway will not get the configuration Device configuration Logging Visualization Alarms Show Advanced Config GPS Enabled o E Tis set BaudRate set Distance a set Modbus Physical set BaudRate z set Parity set StopBits im _set 2 5 1 GPS Enable Switch the D sub connection of the Gateway into GPS mode Baud Rate The baud rate which the GPS receiver communicates with the Gateway Distance The distance the GPS position has to move before a new position is sent up to Netbiter Argos 2 5 2 Modbus Physical The port on the Gateway used for the Modbus communication Baud Rate The baud rate which the Modbus port communicates with connected Modbus devices Party Number of parity bits with which the Modbus port communicates with connected Modbus devices Stop Bits The number of stop bits with which the Modbus port communicates with connected Modbus devices netbiter 4a Netbiter Argos ASG User Manual 4a Rev 1 00 2 6 Synchronize the configuration The final step to finish the configurat
50. to finalize the export of the Device Template netbiter 4a Netbiter Argos AS User Manual 4d Rev 1 00 8 HMS Support The support is accessed from the Netbiter Support web page and is found at www support netbiter com 1 Click on the Request Support button Request Support TAG ee assistance 2 Fill in as much information you can about your problem Fields marked with a red asterisk are required Request Support Request support or follow your existing support issues online Login to track your existing support issues online If you dont have any login fill out the form below User Password Lost Password Request support To register a support issue on Netbiter fill out the form below We will automatically send you login information for tracking the support issue online You will get an email to the registered address as soon as the support issue is updated by our support team First Name Last Name Company Name Email Address Phone Confirm Email Address Make sure you type in your correct email Choose your support office gt Login information issue updates will be sent to this email choose office If you do net receive any email check your spam filter settings Product Version Revision MAC ID IMEI Device ID Serial Title Description Upload File Fh rrr V Receive technical support related information via email Max 8 per year Submit
51. v 1 00 6 Profiles Profiles are handled in the Profile menu under the Management menu So i iri Projects All systems Templates All dashboards TEETE Vickie PE Account Netbiter_Argos anagement Profiles Profiles pe oe d Profiles Add profile j Profile type Profile name Virtual Netbiter EC220 Starter kit View Copy Modbus DATAKOM DKG 705 View Copy Modbus Deep Sea Electronics 8610 View Copy Modbus DEIF GC 1F View Copy Modbus Lovato RGK60 View Copy Modbus Woodward Easygen 3000 View Copy User defined device profiles Profile type roile name There are two types of profiles e Device Profiles A Profile created and possible to edit by the user e Global Profiles A predefine Profile that is not possible to edit by the user Both types of Profiles can consist of two parts 1 Parameter configuration a Logging parameters b Visualization parameters c Alarm parameters 2 Dashboard 6 1 Device Profile 6 1 1 Create a Device Profile 1 Click on the Add profile tab under the Profiles menu Presentation sports oee Projects All systems Templates Profiles AIl dashboards Profiles Add profile Profile name Test Profile Profile type Virtual Template Netbiter EasyConnect EC220 7 save 2 Enter the Profile name 3 Choose the Profile type to use a Virtual type is used when the Profile is being created for a Netbiter gateway b V
52. vel of subscription and how many systems that can use the Subscription All Systems in the account are listed and displayed with Subscription Level and when it will expire System subscription overview a a a e e a y umaaaaaaaaaaaaaaamaaeaeoeou e_m Fhe P ry gt N J ar Name Device It ALI i Ley ALUVWVALCUG jec i ou a Netbiter System 353234023061169 MyFirstProject Free Yes re Demon WB subscription expired Ml subscription less than 3 month Ml subscription more than 3 month Name The Remote system name Device ID The Remote gateways Device ID that was supplied with the Remote gateway Project The project which the Remote system belongs to Level The subscription key level for the system Activated Displayes if the Remote system is active to be used in this account Expiration date The subscription key expiration date The background is color coded as following More than three months left Select Check the Remote systems to which a subscription key will be deployed 4 1 1 Add Subscription key Adding a new Subscription key is done by clicking on the add subscription key button and enter the Subscription key Enter subscription key i 85y Y8y p3T u6R activate cancel When the Subscription key is activated it is placed in the Subscription key list o Subscription SMS Users Subscription key Order re Information Used dd date Select 85y Y8y p3
Download Pdf Manuals
Related Search
Related Contents
MPX-70 DMR-BRT300(操作編) (10.36 MB/PDF) Allegato 3 Capitolato tecnico - Università degli Studi di Padova NL50 USER MANUAL CRU DataPort 5 Copyright © All rights reserved.
Failed to retrieve file