Home
PRIMERGY RX200 S7 Server
Contents
1. gt Follow the on screen instructions see also section Configuring the server and installing the operating system with the ServerView Installation Manager on page 75 or section Configuring the server and installing the operating system without the ServerView Installation Manager on page 76 System already installed gt Press the On Off button The server is switched on performs a system test and boots the operating system In the case of configurations with a large memory size the boot process may be prolonged and the screen may remain dark for about 20 seconds Switching the server off The Power on indicator see figure 5 on page 59 lights up green gt Shut down the operating system properly The server is switched off automatically and enters standby mode The power on indicator lights up orange If the operating system does not switch off the server automatically press the On Off button for at least four seconds and or send a corresponding control signal for power button override Other On Off options Besides the On Off button the server can be switched ON and OFF in the following ways Timer controlled switch on off Using the ServerView Operations Manager or iRMC S3 you can configure that the server is switched on off controlled by an internal timer Ring indicator The server is switched on by an internal or external modem Wake up On LAN WOL The server is switched on by a command
2. 11 1 2 Documentation overview 0 002 eee eee 12 1 3 Notational conventions 2 0002 eee eee 14 2 Functional overview 2 6 ee ee eee ee es 15 2 1 FeatU NGS is is EER eGR GREE SE SESS PO RE eGo 15 2 2 Server specification 00 2002 ee eee 25 3 Installation steps overview 2 2 ee ee eee 33 4 Important information ss Es Ek EE ke ke ei 35 4 1 Safety instructions ss ss Es ks ek eee eee 35 4 2 ENERGY STAR s ss 8 pe N 8 GR ee bebe e 2G bs 43 4 3 CE conformity ss ku RR RR ER eae eee ee Re 43 4 4 FCC Class A Compliance Statement 44 4 5 Transporting the server 2 eee eee ee ee 45 4 6 Notes on installing the serverintherack 46 4 7 Environmental protection 2 0 00 ee ee ke 47 5 Hardware installation 2 es se ee kk ee es 49 5 1 Unpacking the server 00222 ee ee ke 50 5 2 Installing removing the server in from the rack 51 5 3 Connecting devices tothe server 4 53 5 4 Connecting the server to the mains 55 5 4 1 Using the cable clamp 2 2 45 56 RX200 S7 Operating Manual Contents 5 5 6 1 6 1 1 6 1 11 6 1 1 2 6 1 1 3 6 1 2 6 1 3 6 2 6 3 631 0 3 2 6 3 3 6 3 4 6 4 7 1 8 1 8 2 8 3 8 4 8 5 8 6 8 7 8 8 Notes on connecting disconnecting cables 57 Starting up and operation 200252058 59 Controls and indicators 2 02 85222 59 F
3. Advantages of the ServerView Installation Manager Wizard assisted configuration of your server hardware and disk arrays Wizard assisted installation of all leading server operating systems Wizard assisted creation of configuration files for unattended installation of several PRIMERGY servers with identical hardware configurations Installation of drivers and additional software The software that can be installed depends on your server s hardware configuration This configuration is detected automatically Descriptions of operating systems not covered in the controller manual are provided in the corresponding readme under http www fujitsu com global services computing server ia driver index html for the EMEA market http jp fujitsu com platform server primergy downloads for the Japanese market To find out how to operate the ServerView Installation Manager and for further information refer to the associated manual If you are using the ServerView Installation Manager you can skip the following section on how to configure the server and install the operating system Continue from section Cleaning the server on page 77 RX200 S7 Operating Manual 75 Starting up and operation 6 3 4 Configuring the server and installing the operating system without the ServerView Installation Manager Configuring the onboard SAS SATA controller Configure the controller as described in section Configuring
4. CO Operating Manual English FUJITSU PRIMERGY RX200 S7 Server Operating Manual Edition April 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Feel free to send us your comments by e mail to manuals ts fujitsu com Certified documentation according to DIN EN ISO 9001 2008 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2008 cognitas Gesellschaft fur Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2012 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual No part of this manual may be reproduced in any form without the prior written permission of Fujitsu Microsoft Windows Windows Server and Hyper V are trademarks or registered trademarks of Microsoft Corporation in th
5. Status LED at system rear side Global error CSS ID indicator orange yellow blue LAN connection indicator green LAN speed indicator green yellow 28 Operating Manual RX200 S7 Functional overview Dimensions Weight Rack W x D x H 482 mm bezel 431 mm body x 768 mm bezel 718 mm body x 43 mm Mounting depth rack 743 mm Height unit rack 1U 19 rackmount Yes Mounting cable 200 mm 1000 mm rack recommended depth rack Weight 18 kg Weight notes actual weight may vary depending on configuration Rack mounting kit rack mounting kit as option Ambient conditions Environment class 3K2 EN 60721 IEC 721 Part 3 3 Environment class 2K2 EN 60721 IEC 721 Part 3 2 Temperature Operation 3K2 10 C 35 C Transport 2K2 25 C 60 C Humidity 10 85 non condensing Condensation during operation must be avoided Noise level The acoustic noise values are depending on the system configuration min 1xPSU 1xCPU max 2xPSU 2xCPU Sound power level Lwad lt 4 9 B standby lt 6 8 B standby ISO 9296 lt 7 3 B operation lt 8 2 B operation Sound pressure level at lt 34 dB A standby lt 50 db A standby adjacent workstation lt 58 dB A operation lt 60 db A operation Lpam ISO 9296 RX200 S7 Operating Manual 29 Functional overview E
6. In the table Acclimatization time the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server was exposed previously outside transport or storage temperature RX200 S7 Operating Manual 49 Hardware installation 5 1 Unpacking the server CAUTION Follow the safety instructions in Important information on page 35 The server must always be lifted or carried by at least two people For the Japanese market please refer to EEO CHER Do not unpack the server until it is at its installation location gt Transport the server to the place where you want to set it up gt Unpack all individual parts Keep the original packaging in case you want to transport the server again applies only to EMEA market gt Check the delivery for any damage during transport gt Check whether the items delivered match the details on the delivery note The product name and serial number of the product can be found on the ID card see section Front of server on page 59 gt Notify your supplier immediately should you discover that the items delivered do not correspond to the delivery note 50 Operating Manual RX200 S7 Hardware installation 5 2 Installingiremoving the server in from the rack CAUTION e Please observe the safety information and notes on rack mounting in chapter Important information on page 35 and section Notes on i
7. Manual RX200 S7 Troubleshooting and tips 8 4 Flickering stripes on monitor screen CAUTION Switch off the server immediately Risk of damaging the server Monitor does not support the set horizontal frequency gt Find out which horizontal frequency your monitor screen supports You will find the horizontal frequency also known as line frequency or horizontal deflection frequency in the documentation for your monitor Refer to the documentation for your operating system or the software for the screen controller for details of how to set the correct horizontal frequency for your monitor and follow the procedure accordingly 8 5 No screen display or display drifts The wrong horizontal frequency or resolution has been selected for the monitor or for the application program gt Find out which horizontal frequency your monitor screen supports You will find the horizontal frequency also known as line frequency or horizontal deflection frequency in the documentation for your monitor Refer to the documentation for your operating system or the software for the screen controller for details of how to set the correct horizontal frequency for your monitor and follow the procedure accordingly RX200 S7 Operating Manual 83 Troubleshooting and tips 8 6 Incorrect date and time gt Set the date and time in the operating system or in the BIOS Setup under the Main menu using System Date and System Time respective
8. Remote Management Controller Integrated Remote Management Controller RMC S3 32 MB attached memory incl graphics controller IPMI 2 0 compatible Trusted Platform Module TPM Infineon separate module TCG V1 2 compliant option Slots PCI Express 3 0 x8 3 x low profile PCI Express 3 0 x16 1 x low profile Slot notes One PCle Gen3 x8 slot may be occupied with a Modular On Board LAN controller if configured One PCle Gen3 x8 slot may be occupied with a Modular RAID controller if configured Drive bays Hard disk bay configuration 4 x 2 5 inch or 8 x 2 5 inch Accessible drive bays 1 x 5 25 0 5 inch for DVD RW Blu ray only for base unit 4 x 2 5 inch HDD Notes accessible drives all possible options described in relevant system configurator RX200 S7 Operating Manual 27 Functional overview Operating Panel Operating buttons On off button Reset button NMI button ID button Status LEDs Global error indicator orange ID indicator blue HDD SSD activity indicator green Power on indicator orange yellow green HDD SSD error indicator orange PSU error indicator orange Temperature error indicator orange CPU error indicator orange Memory error indicator orange Fan error indicator orange ID indicator blue CSS indicator yellow
9. be replaced The warranty is void if the server is damaged during installation or replacement of system expansions Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor Otherwise you may damage your monitor If you are in any doubt contact your sales outlet or customer service center Before installing removing internal options to from the server turn off the server all peripheral devices and any other connected devices Also unplug all power cords from the outlet Failure to do so can cause electric shock Do not damage or modify internal cables or devices Doing so may cause a device failure fire or electric shock Devices inside the server remain hot after shutdown Wait for a while after shutdown before installing or removing internal options The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity Before handling them first touch a metal part of the server to discharge static electricity from your body Do not touch the circuitry on boards or soldered parts Hold the metallic areas or the edges of the circuit boards 38 Operating Manual RX200 S7 Important information CAUTION e Install the screw removed during installation detaching Internal Options in former device position To use a screw of the different kind causes a breakdown of equipment e The installation indicated on this note is someti
10. place heavy objects on CDs DVDs BDs e Do not write with ballpoint pen or pencil on the label printed side e Donotattach stickers or similar to the label side Doing so may cause rotational eccentricity and abnormal vibrations e When a CD DVD BD is moved from a cold place to a warm place moisture condensation on the CD DVD BD surface can cause data read errors In this case wipe the CD DVD BD with a soft dry cloth then let it air dry Do not dry the CD DVD BD using devices such as a hair dryer e To avoid dust damage and deformation keep the CD DVD BD in its case whenever it is not in use e Do not store CDs DVDs BDs at high temperatures Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided You can prevent damage from the optical drive and the CDs DVDs BDs as well as premature wear of the disks by observing the following suggestions Only insert disks in the drive when needed and remove them after use Store the disks in suitable sleeves Protect the disks from exposure to heat and direct sunlight Laser information The optical drive complies with IEC 60825 1 laser class 1 CAUTION The optical drive contains a light emitting diode LED which under certain circumstances produces a laser beam stronger than laser class 1 Looking directly at this beam is dangerous Never remove parts of the optical drive casing RX200 S7 Operating Manual 41 Important informati
11. speeds data loss Under certain circumstances sharp CD DVD BD fragments can pierce the cover of the optical drive equipment damage and can fly out of the device danger of injury particularly to uncovered body parts such as the face or neck High humidity and airborne dust levels are to be avoided Electric shocks and or server failures may be caused by liquids such as water or metallic items such as paper clips entering a drive Shocks and vibrations are also to be avoided Do not insert any objects other than the specified CDs DVDs BDs Do not pull on press hard or otherwise handle the CD DVD BD tray roughly Do not disassemble the optical drive Before use clean the optical disk tray using a soft dry cloth As a precaution remove disks from the optical drive when the drive is not to be used for a long time Keep the optical disk tray closed to prevent foreign matter such as dust from entering the optical drive Hold CDs DVDs BDs by their edges to avoid contact with the disk surface 40 Operating Manual RX200 S7 Important information e Do not contaminate the CD DVD BD surface with fingerprints oil dust etc If dirty clean with a soft dry cloth wiping from the center to the edge Do not use benzene thinners water record sprays antistatic agents or silicone impregnated cloth e Be careful not to damage the CD DVD BD surface e Keep the CDs DVDs BDs away from heat sources e Do not bend or
12. the documentation for the RAID controller or gt Remove and reinstall the drive while the system is switched ON If the drive continues to be shown as defective then replace it 8 10 Error message on screen The meaning of the error message is explained in the documentation for the relevant components and programs on the ServerView Suite DVD 2 8 11 Expansion cards or onboard devices not recognized When an expansion card is added other expansion cards or onboard devices might not be recognized gt Reinstall the drivers for the expansion cards or onboard devices that are not recognized 8 12 Temperature warning A temperature warning is output to the hardware event log and OS event log or ServerView issues a notification of a temperature warning such as by a popup message The above log is output or the above notification is issued by ServerView when the ambient temperature is within 30 to 35 C which is near the upper limit of the temperature boundaries 10 to 35 C This is to notify the administrator before the ambient temperature actually exceeds the range of the temperature boundaries RX200 S7 Operating Manual 85 Troubleshooting and tips gt Although continued use within the temperature boundaries poses no problems within itself reconsider the surrounding environment conditions if this log is output or if ServerView issues this notification 8 13 No effect of keyboard or mouse Typing the keyboard do
13. the server and installing the operating system without the ServerView Installation Manager on page 76 i You will find more information on installing the server remotely or locally in the ServerView Suite Installation Manager user s guide on the ServerView Suite DVD 2 under Industry Standard Servers Software Server View Suite Server Installation and Deployment 34 Operating Manual RX200 S7 4 Important information In this chapter you will find essential information regarding safety when working on your server 4 1 Safety instructions The following safety instructions are also provided in the manual Safety Notes and Regulations or amp OIE This device meets the relevant safety regulations for IT equipment If you have any questions about whether you can install the server in the intended environment please contact your sales outlet or our customer service team CAUTION e The actions described in this manual shall be performed by technical specialists A technical specialist is a person who is trained to install the server including hardware and software e Repairs to the device that do not relate to CSS failures shall be performed by service personnel Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability e Any failure to observe the guidelines in this manual and any improper repairs could expose the user to risks el
14. this manual Never connect or disconnect data transmission lines during a storm risk of lightning hazard Make sure that no objects e g jewelry paperclips etc or liquids can get inside the server risk of electric shock short circuit In emergencies e g damaged casing controls or cables penetration of liquids or foreign bodies switch off the server immediately remove all power plugs and contact your sales outlet or customer service team CAUTION Hazardous moving parts Keep away from moving fan blades RX200 S7 Operating Manual 37 Important information CAUTION Proper operation of the system in accordance with IEC 60950 1 2 resp EN 60950 1 2 is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted electric shock cooling fire protection interference suppression Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals If you install other expansions they may damage the system or violate the safety regulations Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet The components marked with a warning notice e g lightning symbol may only be opened removed or exchanged by authorized qualified personnel Exception CSS components can
15. via the LAN Magic Packet After power failure RX200 S7 Operating Manual 71 Starting up and operation The server automatically reboots following a power failure depending on the settings in the BIOS or in iRMC S3 Power button override The system can be switched off hard power off by keeping the On Off button approximately 4 5 seconds CAUTION There is a risk that data may be lost iRMC 3 iIRMC S3 offers various options for switching the server on and off e g via the Power On Off page of the iRMC S3 Web interface CAUTION when turning off the power Windows Server 2008 The operation of the power switch can be specified as Do Nothing Stand by Hibernate and Shutdown depending on the OS settings The default is Shutdown On this server functions corresponding to Stand by and Hibernate are supported as BIOS and hardware functions However some drivers and software installed in the server do not support these functions For this reason functions corresponding to Stand by and Hibernate are unavailable on this server When the operating mode is set to Stand by or Hibernate the system may operate improperly or hard disk data may be corrupted For details about operating mode settings refer to the manual supplied with the OS 72 Operating Manual RX200 S7 Starting up and operation 6 3 Configuring the server This section contains information about confi
16. will switch off the system CAUTION Risk of loss of data The On Off button does not disconnect the server from the mains voltage To disconnect from the mains completely remove the power plug s NMI button CAUTION Do not press Risk of loss of data The NMI button may only be used by service personnel Reset button Pressing the reset button reboots the system CAUTION Risk of loss of data ID button ID LED lights up blue on the front and on the rear of the server when the ID button is pressed Both ID indicators are synchronized 60 Operating Manual RX200 S7 Starting up and operation 6 1 1 2 O AN Indicators on the control panel Power on indicator three colors Lights orange when the server is switched off but mains voltage is present Lights up yellow during power up delay If the server is switched off and then immediately switched on again a server is only restarted after a power up delay This prevents a current overload for example You can set the power up delay in seconds in the BIOS setup in the Server Menu menu with Power Cycle Delay Lights up green when the server is switched ON Flashes green if the server has been switched on and is in standby mode or if the server is in a sleep state HDD SSD activity indicator green Flashes green when an internal hard disk drive is being accessed Global Error indicator orange Lights up orange if a prefailure event
17. 15000 C289 the order number for the Japanese market please refer to the configurator of the server ittp jp fujitsu com platform server primergy system The PDF files of the manuals can also be downloaded free of charge from the Internet The overview page showing the online documentation available on the Internet can be found using the URL for EMEA market http manuals ts fujitsu com The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option For the Japanese market Please refer to the following URL for the latest product manuals http jp fujitsu com platform server primergy manual Before using the product please check for additional information that may be available under the following URL http jp fujitsu com platform server primergy products note Further sources of information ServerView Suite Glossary on the ServerView Suite DVD 2 Manual for the monitor Documentation for the boards and drives Operating system documentation Information files in your operating system RX200 S7 Operating Manual 13 Introduction 1 3 Notational conventions The following notational conventions are used in this manual Text in italics indicates commands or menu items Quotation marks indicate names of chapters and terms that are being emphasized gt describes activities that must be performed in the order shown CAUTION pay parti
18. 3 Hardware installation One optional video connector 1 one optional Front LAN connector 2 and two additional USB connectors 3 are located on the front of the server figure 3 Figure 3 Connectors on the front Connecting the keyboard mouse and monitor gt Connect the keyboard and mouse to the USB connectors of the server gt Connect the monitor to one of the two video connectors at the front or rear The front video connector is designed for maintenance issues If you i connect a monitor to the video connector at the front the video connector at the rear is deactivated A monitor connected to the front must have at least the same resolution as the monitor connected to the rear A console bypass is not possible via the video connector at the front If a separate graphics card is installed in a slot the graphic controller i on the system board is automatically deactivated The corresponding video connector can not be used Plug the video cable of the monitor into the video connector of the graphics card gt Connect the power cord of the monitor to the mains socket strip of the rack The rated current for the monitor is indicated on the technical data label on the monitor or in the operating manual for the monitor 54 Operating Manual RX200 S7 Hardware installation 5 4 Connecting the server to the mains In its basic configuration level the server has a hot plug power supply unit Ase
19. Hardware installation The main features of Fujitsu rack systems are as follows rail systems that can be mounted without tools support systems having a linear alignment feature to ensure that they can be adjusted to different rack depths Asymmetrical PRIMECENTER Rack and DataCenter Rack provide an enhanced cable management in the lateral rack area 3rd party racks Installation in most current rack systems from other manufacturers 3rd party racks is also supported For details please contact your sales representative 52 Operating Manual RX200 S7 Hardware installation 5 3 Connecting devices to the server The connectors for external devices are on the front and rear of the server The additional connectors available on your server depend on the expansion cards installed For further information refer to the PRIMERGY RX200 S7 Server Upgrade and Maintenance Manual The standard connectors are marked with symbols and some are color coded Figure 2 Connection panel on the rear 1 Shared LAN connector 4 Video connector for standard operation 2 Standard LAN connector 5 3 USB connectors 3 Management LAN connector Some of the devices that can be connected may require the installation and setting up of special software e g drivers see the documentation for the connected device gt Connect the desired devices to the server RX200 S7 Operating Manual 5
20. To protect your system and data internally against unauthorized access you can use the BIOS Setup security functions 7 1 BIOS Setup security functions The Security menu in BIOS Setup offers various options for protecting your data from unauthorized access By combining these options you can also achieve optimum protection for your system can be found in the D3032 BIOS Setup Utility for PRIMERGY RX200 S7 Reference Manual i A detailed description of the Security menu and how to assign passwords RX200 S7 Operating Manual 79 Property and data protection 80 Operating Manual RX200 S7 8 Troubleshooting and tips CAUTION Follow the safety instructions in the Safety notes and regulations manual or EO CE and in chapter Important information on page 35 If a fault occurs attempt to resolve it using the measures described inthis chapter inthe documentation for the connected devices inthe help systems of the software used If you fail to correct the problem proceed as follows gt Make alist of the steps performed and the circumstances that led to the fault Also make a list of any error messages that were displayed gt Switch off the server gt Contact our customer service team 8 1 Power on indicator remains unlit The power on indicator remains dark after you switch on your device Power cable incorrectly connected gt Make sure that the power cable s is are correc
21. al mains voltage lies within these limits This device must only be connected to properly grounded power outlets or insulated sockets of the rack s internal power supply with tested and approved power cords Ensure that the device is connected to a properly grounded power outlet close to the device 36 Operating Manual RX200 S7 Important information CAUTION Ensure that the power sockets on the device and the properly grounded power outlets are freely accessible The On Off button or the main power switch if present does not isolate the device from the mains power supply To disconnect it completely from the mains power supply unplug all network power plugs from the properly grounded power outlets Always connect the server and the attached peripherals to the same power circuit Otherwise you run the risk of losing data if for example the server is still running but a peripheral device e g memory subsystem fails during a power outage Data cables must be adequately shielded Ethernet cabling has to comply with EN 50173 and EN 50174 1 2 standards or ISO IEC 11801 standard respectively The minimum requirement is a Category 5 shielded cable for 10 100 Ethernet or a Category 5e cable for Gigabit Ethernet Route the cables in such a way that they do not create a potential hazard make sure no one can trip over them and that they cannot be damaged When connecting the server refer to the relevant instructions in
22. backup of the TPM content To do this follow the third party manufacturer s instructions Without this backup if the TPM or the system board is faulty you will not be able to access your data Ifa failure occurs please inform your service about the TPM activation before it takes any action and be prepared to provide them with your backup copies of the TPM content 16 Operating Manual RX200 S7 Functional overview Slots for expansion cards The server can be flexibly expanded via three external slots 1x PCle x16 and 2x PCle x8 There is a fourth slot PCle Gen3 x8 that is internal and designed for an optional SAS SATA RAID controller Hard disk drives The server can be equipped with a maximum of four variant with DVD slot or eight 2 5 inch HDD modules Each HDD module can accommodate an SAS SATA hard disk drive or an SATA SSD drive with a maximum height of 1 inch The module is connected to the SAS SATA backplane wirelessly This allows HDD modules to be plugged in or pulled out easily Four SAS SATA hard disk drives can be controlled by the onboard SAS SATA controller To control further SAS SATA hard disk drives an additional RAID controller must be installed Mixed configurations of SAS HDDs SATA HDDs and SSDs within the same logical drive RAID array are not supported If the server has the corresponding RAID configuration HDD modules can also be replaced during operation Onboard SAS SATA controlle
23. cond hot plug power supply unit can be added to ensure a redundant power supply If one power supply unit is defective the other then guarantees unimpaired operation Each hot plug power supply unit can be replaced during operation see the PRIMERGY RX200 S7 Server Upgrade and Maintenance Manual CAUTION The server is automatically set to a mains voltage in the range 100 240 V You may only operate the server if its rated voltage range corresponds to the local mains voltage gt Connect the power cord to the server power supply unit gt Connect the mains connector to an outlet on the rack s socket strip see also Technical Manual for the rack A phase redundancy in the power supply of the server can be set up if two hot plug power supply units are installed In this case each of the power supply units is either connected to two different phases or to two separate circuits of the internal power supply network RX200 S7 Operating Manual 55 Hardware installation 5 4 1 Using the cable clamp You can secure the power cords in a cable clamp to ensure that the insulated connectors cannot be disconnected from the server accidentally Figure 4 Cable clamp gt Pull the cable clamp up 1 gt Thread the power cord through the cable clamp 2 gt Press the cable clamp down until it engages to secure the cable 3 56 Operating Manual RX200 S7 Hardware installation 5 5 Notes on connecting
24. cular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data i indicates additional information notes and tips 14 Operating Manual RX200 S7 2 Functional overview 2 1 Features This section provides information on the features and technical data of the PRIMERGY RX200 S7 server For information on key characteristics and layout of the system board see the PRIMERGY RX200 S7 Server Upgrade and Maintenance Manual Customer Self Service CSS The PRIMERGY Customer Self Service CSS concept enables you to identify and replace the affected component yourself in the case of certain error scenarios In the CSS concept you can replace the following components yourself in the event of an error Hot plug hard disk drives Hot plug power supply units Memory modules System fans Expansion cards For information on replacing these components see the PRIMERGY RX200 S7 Server Upgrade and Maintenance Manual CSS indicators on the control panel and on the back of the PRIMERGY server provide you with information if a CSS event arises You can also fit your server with a ServerView Local Service Panel which enables you to identify the type of component affected by the error directly on the server In addition CSS errors are displayed in the ServerView Operations Manager the server management sof
25. d Management 24 Operating Manual RX200 S7 Functional overview 2 2 Server specification This section explains the specifications for the server The specifications for this server are liable to be updated without any notice Please be forewarned System Board System board type D3032 Chipset Intel C602 Processor Processor quantity and type 1or 2 Intel E5 2600 family processors Memory Modules Configuration min max Memory slots 24 Memory slot type DDR3 Memory capacity 2 GB 768 GB Memory protection Memory Scrubbing SDDC only for registered DIMMs Hot spare memory support Memory Mirroring support Rank sparing memory support Memory notes Max 8 memory modules CPU with UDIMM low voltage or standard OR quad rank RDIMM max 12 memory modules CPU with single or dual rank RDIMM or single dual rank or quad rank Load Reduced LR DIMM Memory Mirroring with identical modules in both channel pairs of a bank 4 modules per bank Rank sparing or Performance Mode with identical modules in all four channels 4 modules per bank RX200 S7 Operating Manual 25 Functional overview Interfaces USB connectors 6 x USB 2 0 2 x front 3 x rear 1 x USSD Graphics 15 pin 2 x VGA thereof 1 x front optional LAN Ethernet RJ45 2 x 1 Gbit s Ethernet as default Modular On Board LAN with upgrade op
26. disconnecting cables CAUTION Always read the documentation supplied with the device you wish to connect Never connect or disconnect cables during a thunderstorm Never pull on a cable when disconnecting it Always take hold of the cable by the plug Follow the sequence described below to connect or disconnect external devices to or from the server Be sure to wait for 10 seconds or more after shutdown before turning the server on Connecting cables gt Turn off all power and equipment switches gt Disconnect all power plugs from the properly grounded power outlets gt Connect all cables to the server and peripherals gt Plug all data communication cables into the utility sockets gt Plug all power cords into the properly grounded power outlets Disconnecting cables gt Turn off all power and equipment switches gt Disconnect all power plugs from the properly grounded power outlets gt Unplug all data communication cables from the utility sockets gt Disconnect the relevant cables from the server and all the peripherals For connecting or disconnecting LAN cables the server does not need to be powered off To avoid loss of data teaming function has to be enabled RX200 S7 Operating Manual 57 Hardware installation Information for ensuring electromagnetic compatibility All data and signal cables must have sufficient shielding The use of cable type S FTP Cat5 or better is recommended Use of u
27. e USA and other countries Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries Before reading this manual For your safety This manual contains important information for safely and correctly using this product Carefully read the manual before using this product Pay particular attention to the accompanying manual Safety Notes and Regulations and ensure these safety notes are understood before using the product Keep this manual and the manual Safety Notes and Regulations in a safe place for easy reference while using this product Radio interference This product is a Class A ITE Information Technology Equipment In a domestic environment this product may cause radio interference in which case the user may be required to take appropriate measures VCCI A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product s printed circuit board assemblies and in the mouse and keyboard are limited life components Use of these components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product is used in a hot environment The cust
28. e returns recycling and disposal in accordance with local regulations The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2002 96 EC on waste electrical and electronic equipment WEEE This directive sets the framework for returning and recycling used HE equipment and is valid across the EU When returning your used device please use the return and collection systems available to you Further information can be found at http ts fujitsu com recycling Details regarding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or from our recycling center in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 525 1410 Fax 49 5251 525 32 1410 48 Operating Manual RX200 S7 5 Hardware installation CAUTION e Follow the safety instructions in the chapter Important information on page 35 e Do not expose the server to extreme environmental conditions see Ambient conditions on page 29 Protect the server from dust humidity and heat e Make sure that the server is acclimatized for the time indicated in this table before putting it into operation Temperature difference C Minimum acclimatization time hours 5 3 10 5 15 7 20 8 25 9 30 10 Table 1 Acclimatization time
29. ectly inserted Slow flashing Rebuild the data is being restored after changing a drive Fast flashing Identify 64 Operating Manual RX200 S7 Starting up and operation 6 1 2 Rear of server CSS Global Error and ID indicators Figure 8 ID CSS Global Error indicator 1 Global Error CSS ID indicator Global Error indicator orange JX Lights up orange if a prefailure event has been detected that requires precautionary service intervention Flashes orange if an error was detected that requires service intervention Does not light up if there is no critical event If the event is still acute after a power failure the indicator is activated after the restart The indicator also lights up in standby mode You can find more details on the indicated errors in the System Event Log SEL in the ServerView Operations Manager or via the iRMC S3 s Web interface RX200 S7 Operating Manual 65 Starting up and operation CSS CSS indicator yellow Lights up yellow if a prefailure event was detected for a CSS component that you can fix yourself for reasons of precaution with the CSS concept Flashes yellow if an error was detected that you can fix yourself with the CSS concept Does not light up when the system is OK If the event is still acute after a power cycle the indicator is activated after the restart The indicator also ligh
30. ectric shock energy hazards fire hazards or damage the equipment e Before installing removing internal options to from the server turn off the server all peripheral devices and any other connected devices Also unplug all power cords from the power outlet Failure to do so can cause electric shock RX200 S7 Operating Manual 35 Important information Before starting up CAUTION During installation and before operating the device observe the instructions on environmental conditions for your device see Server specification on page 25 If the server has been moved from a cold environment condensation may form both inside and on the outside of the machine Wait until the server has acclimatized to room temperature and is absolutely dry before starting it up Material damage may be caused to the server if this requirement is not met Only transport the server in the original packaging or in packaging that protects it from impacts and jolts Installation and operation CAUTION This unit should not be operated in ambient temperatures above 35 C If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector the power supply s fuse protection must comply with the requirements for non industrial power supply networks for type A connectors The unit automatically adjusts itself to a mains voltage in a range of 100 240 V Ensure that the loc
31. efective 85 8 10 Error message onscreen 2 2 02 ee eee eee 85 8 11 Expansion cards or onboard devices not recognized 85 8 12 Temperature warning ss ee Ek ke ek 85 8 13 No effect of keyboard ormouse 86 8 14 Optical drive cannot read data ss SS aa 86 RX200 S7 Operating Manual Contents Operating Manual RX200 S7 1 Introduction The PRIMERGY RX200 S7 is a rack server that provides high performance expandability and energy efficiency in 1 height unit HU space saving housing Thus the PRIMERGY RX200 S7 is ideal for virtualization and cloud small databases as well as for high performance computing thanks to the top performance of the new Intel Xeon E5 product family Moreover the RX200 S7 delivers a great expandability by supporting up to 768 GB of memory eight hard disk drives and cost saving LAN options to ensure future requirements are met and budgets are saved Thanks to the highly efficient power supply units with an efficiency rate of 94 and the new power management this will result in lower operational costs 1 1 Concept and target groups for this manual This operating manual describes how to install set up and operate your server This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly It contains all the information you need to put your PRIMERGY RX200 S7 into operation To under
32. efore or during installation with the ServerView Installation Manager Using the ServerView Installation Manager is recommended A separate utility is available to the controller for MegaRAID i configuration For further information refer to the SAS Software User s Guide on the ServerView Suite DVD 2 under Industry Standard Servers Expansion Cards Storage Adapters LSI Configuration Software Further information on modular RAID controllers is provided in the Modular RAID Controller Installation Guide on the ServerView Suite DVD 2 under Industry Standard Servers Expansion Cards Storage Adapters LSI SAS SCSI RAID Controllers Descriptions of operating systems not covered in the controller manual are provided in the corresponding readme under http www fujitsu com global services computing server ia driver index html for the EMEA market http jp fujitsu com platform server primergy downloads for the Japanese market 74 Operating Manual RX200 S7 Starting up and operation 6 3 3 Configuring the server and installing the operating system with the ServerView Installation Manager Using the ServerView Installation Manager on the ServerView Suite DVD 1 provided you can conveniently configure the server and install the operating system This includes configuring the server specific settings using the ServerView Configuration Manager and configuring the RAID controller using the ServerView RAID Manager
33. es not display any characters or the mouse cursor does not move gt Check to see whether the keyboard and mouse are connected properly If they are not connected or you replaced them yourself then connect the cables to the server 8 14 Optical drive cannot read data gt Check to see whether the CD DVD BD is inserted properly If the CD DVD BD is not inserted correctly insert the disk so that the label is facing up gt Check to see whether the CD DVD BD is not dirty If the CD DVD BD is dirty wipe it in a radial way with a soft dry cloth gt Check to see whether the CD DVD BD is not scratched or bent If scratched or damaged replace the CD DVD BD 86 Operating Manual RX200 S7
34. guring the server and installing the operating system Make sure that the power saving functions are disabled in the Power menu of the BIOS Setup during operation 6 3 1 Configuring the onboard SAS SATA controller A SAS SATA controller is integrated on the system board You can configure the onboard controller either before or during installation with the ServerView Installation Manager Using the ServerView Installation Manager is recommended The controller has its own configuration utility For further information il refer to the Embedded MegaRAID Software User s Guide on the ServerView Suite DVD 2 under Industry Standard Servers Expansion Cards Storage Adapters LSI SAS SCSI RAID Controllers The SAS functionality needs to be enabled separately by using a ROM1 SCU Key Descriptions of operating systems not covered in the controller manual are provided in the corresponding readme under http www fujitsu com global services computing server ia driver index html for the EMEA market http jp fujitsu com platform server primergy downloads for the Japanese market In the system BIOS the onboard SAS SATA controller can be configured as RAID default or non RAID RX200 S7 Operating Manual 73 Starting up and operation 6 3 2 Configuring the SAS SATA RAID controller The server has a SAS SATA RAID controller with MegaRAID functionality You can configure the SAS SATA RAID controller either b
35. has been detected that requires precautionary service intervention Flashes orange if an error was detected that requires service intervention Does not light up if there is no critical event If the eventis still acute after a power cycle the indicator is activated after the restart The indicator also lights up in standby mode You can find more details on the indicated errors in the System Event Log SEL on the ServerView Local Service Panel in the ServerView Operations Manager or via the IRMC S3 s Web interface RX200 S7 Operating Manual 61 Starting up and operation css 6 1 1 3 CSS indicator yellow Lights up yellow if a prefailure event was detected fora CSS component that you can fix yourself for reasons of precaution with the CSS concept Flashes yellow if an error was detected that you can fix yourself with the CSS concept Does not light up when the system is OK If the event is still acute after a power cycle the indicator is activated after the restart The indicator also lights up in standby mode For more information on the CSS concept see Customer Self Service CSS on page 15 ID indicator blue Lights up blue when the system has been selected by pressing the ID button To deactivate press the button again The ID indicator can also be activated via the ServerView Operations Manager and the iRMC S3 Web interface and its status reported to the ServerVie
36. ibility International CISPR 22 Europe EN 55022 Class A EN 55024 EN 61000 3 2 EN 61000 3 3 USA Canada 47CFR part 15 Class A ICES 003 Taiwan CNS 13438 Class A China GB 9245 GB 17625 Japan VCCI Class A JEITA Korea KN 22 KN 24 CE marking to EU Low Voltage Directive 2006 95 EC directives Electromagnetic compatibility 2004 108 EC RX200 S7 Operating Manual 31 Functional overview 32 Operating Manual RX200 S7 3 Installation steps overview This chapter contains an overview of the steps necessary to install your server Links take you to sections where you can find more detailed information about the respective steps gt First of all carefully read the safety instructions in Important information on page 35 gt Transport the server to the place where you want to set it up gt Unpack the system check the contents of the package for visible transport damage and check whether the items delivered match the details on the delivery note see section Unpacking the server on page 50 gt Make sure that you have all necessary manuals see Documentation overview on page 12 print out the PDF files if required gt Components that have been ordered additionally may be delivered loose with the server For mounting refer to the original component documentation gt Mount the server into the rack see Installing removing the server in from the rack on page 51 gt Wire the server Follow the instruction
37. ied herein The statement for other products will appear in the accompanying documentation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference Causing Equipment Standard ICES 003 for digital apparatus These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in strict accordance with the instructions may cause harmful interference to radio communications However there is no warranty that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cab
38. l be generated for further details see the PRIMERGY RX200 S7 Server Upgrade and Maintenance Manual Cooling The Cool safe cooling concept with improved air flow cooling technology honeycomb design ensures the highest possible performance of the processors at work at the same time the system is extremely reliable thanks to the reduced heat dissipation Base units are supplied with four hot plug fan modules single CPU configuration and depending on CPU type or six hot plug fan modules two CPUs configuration and depending on CPU type Each fan module consists of two fans implemented in one housing Base units with four fan modules operate in a 1 of 4 redundancy base units with six fan modules operate in a 1 of 6 redundancy In other words if one of the four or six fan modules fails the system will operate without any problem For further details see the PRIMERGY RX200 S7 Server Upgrade and Maintenance Manual RX200 S7 Operating Manual 19 Functional overview High level of availability and data security When memory data is accessed 1 bit errors are identified in the main memory and automatically corrected with the error correcting code ECC method ASR amp R Automatic Server Reconfiguration and Restart restarts the system in the event of an error and automatically hides the defective system components The PDA Prefailure Detection and Analysis technology from Fujitsu analyzes and monitors all compone
39. lectrical data hot plug power supply unit Rated voltage range 100 240 V Freguency 50 Hz 60 Hz Rated current with min configuration 1 5A 0 6A Max rated current 8A 4A Effective power 450 800 W Apparent power 646 VA Heat dissipation 2257 kJ h 2141 btu h Main power fuse 16A Protection class Screen resolution Depending on the operating system used the screen resolutions in the following table refer to the graphic controller on the system board The graphic controller is integrated in the IRMC S3 integrated Remote Management Controller Screen resolution Maximum refresh Max number of colours pixel rate Hz 640x480 85 32 bit 800x600 85 32 bit 1024x768 75 32 bit 1152x864 60 16 bit 1280x1024 60 24 bit 1600x1200 60 16 bit 1920x1080 60 16 bit If you are using an external graphics controller you will find details of supported screen resolutions in the Operating Manual or Technical Manual supplied with the graphics controller 30 Operating Manual RX200 S7 Functional overview Compliance with regulations and standards Product safety and ergonomics International IEC 60950 1 2ed Europe Safety EN 60950 1 2ed EN 50371 EN 50392 Ergonomics ISO 9241 3 EN 2941 3 EK1 ITB 2003 2007 USA Canada CSA C22 2 No 60950 1 07 2ed UL 60950 1 2ed Taiwan CNS 14336 China GB 4943 Electromagnetic compat
40. ler on the system board the PRIMERGY RX200 S7 server can also be maintained and serviced remotely This enables remote diagnosis for system analysis remote configuration and remote restart should the operating system or hardware fail ServerView Remote Management ServerView Remote Management is the remote management solution from Fujitsu for PRIMERGY servers ServerView Remote Management and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operation in the event of errors Remote monitoring and maintenance avoids time consuming and costly on site repairs and reduces service costs This leads to a reduction in the total cost of ownership and an excellent return on investment for the remote management solution RX200 S7 Operating Manual 23 Functional overview The administrator can access all system information and information from the sensors such as fan speeds or voltages via the iRMC S3 s Web interface see section IRMC S3 with integrated management LAN connector on page 21 You can also start the text based or graphic console bypass Advanced Video Redirection AVR and connect virtual drives as remote storage More information about the iRMC S3 can be found in the iRMC S2 3 i integrated Remote Management Controller user guide on the ServerView Suite DVD 2 under Industry Standard Servers Software ServerView Suite Out Of Ban
41. les and equipment other than those specified by Fujitsu The correction of interferences caused by such unauthorized modification substitution or attachment will be the responsibility of the user The use of shielded I O cables is required when connecting this equipment to any and all optional peripheral or host devices Failure to do so may violate FCC and ICES rules WARNING This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 44 Operating Manual RX200 S7 Important information 4 5 Transporting the server CAUTION Only transport the server in its original packaging or in packaging that protects it from impacts and jolts Do not unpack the server until it is at its installation location If you need to lift or transport the server ask other people to help you Never lift or carry the device by the Quick Release Levers QRLs on the front panel RX200 S7 Operating Manual 45 Important information 4 6 Notes on installing the server in the rack CAUTION For safety reasons at least two people are required to install the server in the rack because of its weight and size For the Japanese market please refer to RE OIE Never lift the server into the rack using the QRLs Quick Release Levers on the front panel When connecting and disconnecting cables observe the relevant instructions in
42. ly the operating system time may deviate from the system time under Linux and would overwrite the system time in the default setting on shutdown i Note that the operating system may affect the system time For example If the date and time are still wrong after the server has been switched off and back on again replace the lithium battery for a description refer to the PRIMERGY RX200 S7 Server Upgrade and Maintenance Manual or contact our customer service team 8 7 System will not boot The system will not boot after installing a new hard disk drive SAS configuration incorrect gt Check the settings for the hard disk drives SAS Device Configuration and the additional settings in the SAS configuration menu 8 8 Drives reported as dead when starting system This error message can occur when the onboard SAS controller has RAID functionality or the server is equipped with a PCI RAID controller RAID controller configuration incorrect gt Check and correct the settings for the drives using the RAID controller utility Further information is provided in the manual for the RAID controller 84 Operating Manual RX200 S7 Troubleshooting and tips 8 9 Added drive reported as defective RAID controller is not configured for this drive The drive was probably installed when the system was switched off gt Reconfigure the RAID controller for the drive using the corresponding utility Information is provided in
43. mes changed to the kind of possible options without notice Batteries CAUTION e Incorrect replacement of batteries may lead to a risk of explosion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer refer to the PRIMERGY RX200 S7 Server Upgrade and Maintenance Manual e Do not throw batteries into the trash can e Batteries must be disposed of in accordance with local regulations concerning special waste e Replace the lithium battery on the system board in accordance with the instructions in the PRIMERGY RX200 S7 Server Upgrade and Maintenance Manual e All batteries containing pollutants are marked with a symbol a crossed out garbage can In addition the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant Cd Cadmium Hg Mercury Pb Lead RX200 S7 Operating Manual 39 Important information Working with CDs DVDs BDs and optical drives When working with devices with optical drives these instructions must be followed CAUTION Only use CDs DVDs BDs that are in perfect condition in order to prevent data loss equipment damage and injury Check each CD DVD BD for damage cracks breakages etc before inserting it in the drive Note that any additional labels applied may change the mechanical properties of a CD DVD BD and cause imbalance Damaged and imbalanced CDs DVDs BDs can break at high drive
44. nshielded or badly shielded cables may lead to increased emission of interference and or reduced fault tolerance of the device 58 Operating Manual RX200 S7 6 Starting up and operation CAUTION Please note the safety instructions in chapter Important information on page 35 6 1 Controls and indicators 6 1 1 Front of server ee FUJITSU Figure 5 Controls and indicators on the front 1 HDD SSD error indicator 10 HDD SSD activity indicator 2 PSU error indicator 11 Power on indicator 3 Temperature error indicator 12 On Off button 4 CPU error indicator 13 NMI button 5 Memory error indicator 14 Reset button 6 Fan error indicator 15 ID button 7 ID indicator 16 Open close optical drive 8 CSS indicator 17 Optical drive activity indicator 9 Global Error indicator 18 ID card RX200 S7 Operating Manual 59 Starting up and operation ID card You can pull out the ID card as far as it will go and push it back again The ID card contains various system information such as the product name serial number order number MAC addresses and DNS name in the Japanese market only the product name and the serial number 6 1 1 1 NMI RST Control elements On Off button When the system is switched off it can be switched on again by pressing the On Off button When the system is operating pressing the On Off button
45. nstalling the server in the rack on page 46 e Atleast two people are needed to install remove the server in the ny rack For the Japanese market please refer to EEO THES e Do not extend more than one unit out of the rack simultaneously even if the tilt protection is in place If several units are simultaneously extended out of the rack there is a risk that the rack could tip over Fujitsu rack systems The rack systems from Fujitsu support the installation of PRIMERGY servers PRIMECENTER rack PRIMECENTER M1 rack DataCenter rack 19 inch standard rack for the Japanese market 19 inch slimline rack for the Japanese market For information on mounting the server in the rack please refer to the Mounting Instructions provided with the Rack Mounting Kit Further information you find in the manual of your rack system For the Japanese market please refer also to the Rack system structure guide i Online documentation for rack installation can be found on http manuals ts fujitsu com index php id 5406 5605 5606 for the EMEA market http jp fujitsu com platform server primergy manual peri_rack html for the Japanese market To accommodate the ventilation concept and ensure proper ventilation any unused areas in the rack must be sealed using dummy covers The power is supplied via the multiple socket outlets fitted in the rack for the EMEA market RX200 S7 Operating Manual 51
46. nts that are critical for system reliability A RAID controller supports different RAID levels and increase the availability and data security of the system The hot plug HDD modules provide additional availability 20 Operating Manual RX200 S7 Functional overview iRMC S3 with integrated management LAN connector The iRMC S3 integrated Remote Management Controller is a Baseboard Management Controller BMC with integrated management LAN connector and expanded functionality that was previously only available with additional plug in cards In this way the IRMC S3 enables complete control of PRIMERGY servers regardless of system status and thus particularly the control of PRIMERGY servers that are in the out of band system status Major functions supported by the iRMC S3 include the following e Browser access via iRMC S3 s own Web server e Secure communication SSH SSL e Power Management for the managed server depending on its system status e Power Consumption Management e Low noise mode e Connecting virtual drives as remote storage e Text based and graphic console bypass Advanced Video Redirection e Remote Storage e Command Line Interface CLI e Simple interactive or script based iIRMC S3 configuration e Customer Self Service CSS e iRMC S3 s own user management e Multi computer global iRMC S3 user administration using an LDAP Directory Service e Automatic network configuration via DNS DHCP e P
47. omer shall bear the cost of replacing replaceable components which have exceeded their operating life Note that these are only guidelines and do not constitute a guarantee of trouble free operation during the maintenance support period High safety use This product has been designed and manufactured for general uses such as general office use personal use domestic use and normal industrial use It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured RX200 S7 Operating Manual These uses include control of nuclear reactions in nuclear power plants automatic airplane flight control air traffic control traffic control in mass transport systems medical devices for life support and missile guidance control in weapons systems hereafter high safety use Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use Please consult the sales staff of Fujitsu if intending to use this product for high safety use Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning To prevent a momentary voltage drop use of an AC uninterruptible power supply is recommended This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued b
48. on Modules with Electrostatic Sensitive Devices Modules with electrostatic sensitive devices are identified by the following sticker A When you handle components fitted with ESDs you must always observe the following points Figure 1 ESD label e Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs e You must always discharge static build up e g by touching a grounded object before working with such components e Any devices or tools that are used must be free of electrostatic charge e Wear a suitable grounding cable that connects you to the external chassis of the system unit e Always hold components with ESDs at the edges or at the points marked green touch points e Do not touch any connectors or conduction paths on an ESD e Place all the components on a pad which is free of electrostatic charge For a detailed description of how to handle ESD components see the relevant European or international standards EN 61340 5 1 ANSI ESD 20 20 Information for ensuring electromagnetic compatibility All data and signal cables must have sufficient shielding The use of cable type S FTP Cat5 or better is recommended Use of unshielded or badly shielded cables may lead to increased emission of interference and or reduced fault tolerance of the device 42 Operating Manual RX200 S7 Important information Other importan
49. on and Restart ASR amp R in the event that memory modules or processors fail e Power monitoring e End of life monitoring of fans with prompt notification before failure e Watchdog timer for monitoring the operating system with ASR amp R Further information on the ServerView Operations Manager is provided in the associated documentation 22 Operating Manual RX200 S7 Functional overview ServerView Installation Manager You can configure the PRIMERGY server quickly and precisely with the ServerView Installation Manager software provided User guided menus are available for installing the server operating system for further details see section Configuring the server on page 73 Service and support PRIMERGY servers are easy to maintain and modular thus enabling quick and simple maintenance The handles and locks touch points used to exchange components are colored green to ensure simple and immediate recognition In order to prevent the components from being damaged by incorrect handling when they are being installed and removed the areas of all components that can be touched without damaging them are also marked green PRIMERGY diagnostic LEDs fitted on the system board indicate which component memory module processor fan or expansion card is not functioning properly The Flash EPROM program supplied with the Fujitsu utilities supports a fast BIOS update With the iRMC S3 integrated Remote Management Control
50. ower supply of the iRMC S3 via the system standby supply e Full coverage alarm management e System Event Log SEL reading and processing e Out Of Band OOB monitoring The HDD status is read by the Host and reported to the iRMC as a lightpath status The iRMC firmware supports the OOB monitoring of a HDD status RX200 S7 Operating Manual 21 Functional overview More information about the iRMC S3 can be found in the iRMC 82 3 integrated Remote Management Controller user guide on the ServerView Suite DVD 2 under Industry Standard Servers Software ServerView Suite Out Of Band Management Server management Server management is implemented using the ServerView Operations Manager supplied and the PDA Prefailure Detection and Analysis technology from Fujitsu PDA reports the threat of a system error or overload at an early stage allowing preventive measures to be taken The ServerView Operations Manager enables the management of all PRIMERGY servers in the network via a central console The ServerView Operations Manager supports the following functions e Round the clock monitoring regardless of server status e High performance graphical console bypass AVR protected by HTTPS SSL 128 bit e Remote storage via USB e Remote power on e Temperature monitoring of the CPU and the surrounding area e Detailed status and error reports for processors and main memory e Watchdog timer for Automatic Server Reconfigurati
51. products standard_servers index html for the EMEA market http jp fujitsu com platform server primergy concept for the Japanese market Energy saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information doesn t apply to the Japanese market Do not throw away the packaging You may need it later for transporting the system If possible the equipment should only be transported in its original packaging Information on handling consumables Please dispose of printer consumables and batteries in accordance with the applicable national regulations In accordance with EU directives batteries must not be disposed of with unsorted domestic waste They can be returned free of charge to the manufacturer dealer or an authorized agent for recycling or disposal All batteries containing pollutants are marked with a symbol a crossed out garbage can They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants Cd Cadmium Hg Mercury Pb Lead RX200 S7 Operating Manual 47 Important information Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible since this makes it difficult to recycle them Returns recycling and disposal Please handl
52. r A SAS SATA controller is integrated on the system board up to four SAS or SATA hard disk drives can be connected to the controller The LSI Embedded MegaRAID software Software RAID supports RAID levels 0 1 and 10 The SAS functionallity needs to be enabled separately by using a ROM1 SCU Key For more information on configuring the controller see section Configuring the onboard SAS SATA controller on page 73 RX200 S7 Operating Manual 17 Functional overview SAS SATA RAID controller The server is available with the following SAS SATA RAID controllers for operating the internal SAS SATA hard disk drives Modular RAID 0 1 controller with MegaRAID functionality SAS MegaRAID for SAS1 0 and SAS2 0 RAID levels 0 1 10 and 1E are supported for internal hard disk drive configurations Modular RAID 5 6 controller with MegaRAID functionality SAS MegaRAID for SAS1 0 and SAS2 0 RAID levels 0 1 10 1E 5 50 6 and 60 are supported for internal hard disk drive configurations As an option a battery backup unit BBU or a flash backup unit FBU can save the memory content even if the power fails Cache memory size of 512 Mbyte or 1 Gbyte is available For more information on configuring the controller see section Configuring the SAS SATA RAID controller on page 74 Further information on SAS SATA RAID controllers is provided in the Modular RAID Controller Installation Guide on ServerView Suite DVD 2
53. rontof Server eN EE MOE bk RE EEE EE Ow re 59 Control elements c es ia RM Ek EE ee ee EE RD 60 Indicators on the control panel 61 Indicators on the drives 2 2 2 kad eek ee Mk RR N UR 62 Rear of server o cack ce ne eR RR GE ee 65 Indicators of the hot plug system fans 69 Switching the server on and off 25 70 Configuring the server 2 0022 eee eens 73 Configuring the onboard SAS SATA controller 73 Configuring the SAS SATA RAID controller aaa 74 Configuring the server and installing the operating system with the ServerView Installation Manager 75 Configuring the server and installing the operating system without the ServerView Installation Manager 76 Cleaning the server 2 aaa 77 Property and data protection aoaaa aaa a 79 BIOS Setup security functions 79 Troubleshooting and tips ss ss EE EE kk 82 eae 81 Power on indicator remains unlit 5 81 Server switches itself off 2200200 4 82 Screen remains blank 00202 ee eee 82 Flickering stripes on monitor screen 5 83 No screen display or display drifS 83 Incorrect date and time 2 2 2 00 ee eee eee 84 System will not boot 0 00002 ee eee 84 Drives reported as dead when starting system 84 Operating Manual RX200 S7 Contents 8 9 Added drive reported as d
54. s after switching on the server switch the server off immediately see chapter Troubleshooting and tips on page 81 The On Off button does not disconnect the server from the mains voltage To completely disconnect it from the mains voltage remove the power plug s from all PSU inlet connectors Do not move strike or shake the server when it is turned on This can damage the hard disk in the server and cause data loss Turn the server on when the temperature is within its operating environment range 10 35 C For details on the operating environment refer to Safety Precautions When operating the device outside of this operating environment the server may operate improperly and data loss may occur Furthermore Fujitsu cannot be held responsible for any related damage malfunction or loss of data etc Be sure to wait for 10 seconds or more after shutdown before turning the server on again After connecting all power cords wait at least 10 seconds before pressing the On Off button Switching the server on The Power on indicator lights up orange standby mode when the server is connected to the mains i The controls and indicators are shown in figure 5 on page 59 Starting up for the first time For the Japanese market please refer to LU DI BRA lt TE SLY gt Press the On Off button gt Insert ServerView Suite DVD 1 in the DVD drive 70 Operating Manual RX200 S7 Starting up and operation
55. s in sections Connecting devices to the server on page 53 and Notes on connecting disconnecting cables on page 57 gt Connect the server to the mains see section Connecting the server to the mains on page 55 gt Familiarize yourself with the controls and indicators on the front and rear of the server see section Controls and indicators on page 59 RX200 S7 Operating Manual 33 Installation steps overview gt Configure the server and install the desired operating system and applications The following options are available Remote installation with the ServerView Installation Manager With the ServerView Suite DVD 1 provided you can configure the server and install the operating system in a convenient manner Details on how to operate the ServerView Installation Manager as well as some additional information are included in the ServerView Suite Installation Manager user s guide on ServerView Suite DVD 2 under Industry Standard Servers Software ServerView Suite Server Installation and Deployment Configuration information can also be found in section Configuring the server and installing the operating system with the ServerView Installation Manager on page 75 Local configuration and installation with or without the ServerView Installation Manager see section Configuring the server and installing the operating system with the ServerView Installation Manager on page 75 or section Configuring
56. stand the various expansion options you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system RX200 S7 Operating Manual 11 Introduction 1 2 Documentation overview More information on your PRIMERGY RX200 S7 can be found in the following documents Quick Start Hardware PRIMERGY RX200 S7 leaflet only included as a printed copy Quick Start Software Quick Installation Guide DVD booklet only included with the ServerView Suite as a printed copy Safety Notes and Regulations manual 2 amp OCS for the Japanese market Warranty manual REF for the Japanese market ServerView Suite Local Service Concept LSC manual Returning used devices manual and Service Desk leaflet H7A bk amp ER for the Japanese market PRIMERGY RX200 S7 Server Upgrade and Maintenance Manual D3032 BIOS Setup Utility for PRIMERGY RX200 S7 Reference Manual Integrated RAID for SAS User Guide LSI MegaRAID SAS Software User Guide Modular RAID Controller Modular SAS HBA Installation Guide Operating Manual RX200 S7 Introduction PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2 The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server If you no longer have the ServerView Suite DVDs you can obtain the relevant current versions using the order number U
57. supply unit Flashes green when the server is switched off but mains voltage is present standby mode Lights up green when the server is switched on and functioning properly Flashes orange when a predictable error has been detected but the power supply unit is still running Lights up orange in case of OCP OVP or when the fan of the power Supply unit has failed 450 W power supply unit Flashes green when the server is switched off but mains voltage is present standby mode Lights up green when the server is switched on and functioning properly Flashes orange when a predictable error has been detected but the power supply unit is still running Lights up orange in case of OCP OVP or when the fan of the power Supply unit has failed 68 Operating Manual RX200 S7 Starting up and operation 6 1 3 Indicators of the hot plug system fans A fan status indicator LED on the system board is assigned to each system fan The status indicators are not visible unless the housing is open The respective LED is set with commands in Server Management LED Meaning lights green Fan is operational lights orange Possible fan failure rotation speed less than 70 of the original speed or fan failure RX200 S7 Operating Manual 69 Starting up and operation 6 2 Switching the server on and off CAUTION If nothing appears on the screen but flickering stripe
58. t information e During cleaning observe the instructions in section Cleaning the server on page 77 e Keep this operating manual and the other documentation close to the device All documentation must be included if the equipment is passed on to a third party 4 2 ENERGY STAR 4 3 d ENERGY STAR Products that have been certified compliant with ENERGY STAR and identified as such are in full compliance with the specification at shipping Note that energy consumption can be affected by software that is installed or any changes that are made to the hardware configuration or BIOS or energy options subsequently In such cases the properties guaranteed by ENERGY STAR can no longer be assured The ServerView Operations Manager user guide contains instructions for reading out measurement values including those relating to current energy consumption and air temperatures Either the Performance Monitor or the Task Manager can be used to read out CPU utilization levels CE conformity The system complies with the requirements of the EC directives 2004 108 EC regarding Electromagnetic Compatibility and 2006 95 EC Low Voltage Directive This is indicated by the CE marking CE Communaut Europ enne RX200 S7 Operating Manual 43 Important information 44 FCC Class A Compliance Statement If there is an FCC statement on the device it applies to the products covered in this manual unless otherwise specif
59. the Important Information chapter of the technical manual for the corresponding rack The technical manual is supplied with the corresponding rack When installing the rack make sure that the anti tilt mechanism is correctly fitted Do not extend more than one unit out of the rack simultaneously even if the tilt protection is in place If several units are simultaneously extended from the rack there is a risk that the rack could tip over See the safety information of the rack and the warning label The rack must be connected to the power supply by an authorized specialist electrician If the server is integrated into an installation that draws power from an industrial power supply network with an IEC309 type connector the power supply s fuse protection must comply with the requirements for non industrial power supply networks for the type A connector 46 Operating Manual RX200 S7 Important information 4 7 Environmental protection Environmentally friendly product design and development This product has been designed in accordance with the Fujitsu standard for environmentally friendly product design and development This means that key factors such as durability selection and labeling of materials emissions packaging ease of dismantling and recycling have been taken into account This saves resources and thus reduces the harm done to the environment Further information can be found at https fujitsu com
60. the onboard SAS SATA controller on page 73 Configure SAS SATA RAID controller with MegaRAID functionality Configure the controller as described in section Configuring the SAS SATA RAID controller on page 74 Installing the operating system gt Insert the DVD for the operating system you want to install gt Reboot the server gt Follow the instructions on screen and in the manual for the operating system 76 Operating Manual RX200 S7 Starting up and operation 6 4 Cleaning the server CAUTION Switch off the server and disconnect the power plugs from the properly grounded power outlets Do not clean any interior parts yourself leave this job to a service technician Do not use any cleaning agents that contain abrasives or may corrode plastic Ensure that no liquid enters the system Ensure that the ventilation areas of the server and the monitor are clear Do not use any cleaning sprays including flammable types It may cause a device failure or a fire Clean the keyboard and the mouse with a disinfecting cloth Wipe the server and monitor casing with a dry cloth If particularly dirty use a cloth that has been moistened in a mild domestic detergent and then carefully wrung out RX200 S7 Operating Manual 77 Starting up and operation 78 Operating Manual RX200 S7 7 Property and data protection The rack model is protected against unauthorized access by a lockable rack door
61. tions to 2 x 1 Gbit s RJ45 4 x 1 Gbit s RJ45 or 2x 10 Gbit s SFP Management LAN RJ45 1 x dedicated management LAN connector for IRMC S3 10 100 1000 Mbit s Management LAN traffic can be switched to shared onboard Gbit LAN connector Shared 10Gbit s SFP Management LAN as option if Modular On Board LAN 2 x 10 Gbit s is configured Front management LAN connector as option Onboard or integrated controllers RAID Controller RAID 5 6 Ctrl HDD SAS 6 Gb LSI 8 ports ext RAID level 0 1 10 5 50 6 60 512 MB Cache Optional BBU based on LSI SAS2108 Integrated RAID 5 6 Ctrl HDD SAS 6 Gb Fujitsu 8 ports int RAID level 0 1 10 5 50 6 60 1024 MB Cache Optional FBU based on LSI SAS2208 Integrated RAID 5 6 Ctrl HDD SAS 6 Gb Fujitsu 8 ports int RAID level 0 1 10 5 50 6 60 512 MB Cache Optional BBU based on LSI SAS2108 Integrated RAID 0 1 Ctrl SAS SATA 6 Gb Fujitsu 8 ports int RAID level 0 1 10 No BBU support based on LSI SAS2008 SATA Controller Intel C602 1 x SATA channel for ODD 26 Operating Manual RX200 S7 Functional overview LAN Controller Intel Ethernet Controller 1350 2 x 10 100 1000 Mbit s Ethernet I O acceleration as default Modular On Board LAN with upgrade options to 2 x 1 Gbit s 4 x 1 Gbit s or 2 x 10 Gbit s PXE Boot via LAN from PXE server iSCSI boot also diskless
62. tly connected to the server and the grounded power outlet s Power supply overloaded gt Disconnect the server power plug s from the grounded power outlet s gt Waita few minutes before you plug it them into the grounded power outlet s again gt Switch on your server RX200 S7 Operating Manual 81 Troubleshooting and tips 8 2 Server switches itself off Server Management has detected an error gt Check the error list of System Event Log in ServerView Operations Manager or in the iRMC S3 web interface and attempt to eliminate the error 8 3 Screen remains blank Monitor is switched off gt Switch on your monitor Screen has gone blank gt Press any key on the keyboard or gt Deactivate screen saver Enter the appropriate password Brightness control is set to dark gt Set the brightness control on the monitor to light For detailed information refer to the operating manual supplied with your monitor Power cable or monitor cable not connected gt Switch off the monitor and the server gt Check whether the power cable is properly connected to the monitor and to the grounded power outlet gt Check whether the monitor cable is properly connected to the server and monitor if it is plugged in with a connector If a separate graphics card is installed in the server then the monitor cable must be connected to the graphics card gt Switch on the monitor and the server 82 Operating
63. ts up in standby mode For more information on the CSS concept see Customer Self Service CSS on page 15 ID ID indicator blue Lights up blue when the system has been selected by pressing the ID button To deactivate press the button again The ID indicator can also be activated via the ServerView Operations Manager and the iRMC S3 Web interface and its status reported to the ServerView Operations Manager and the iIRMC Sa 66 Operating Manual RX200 S7 Starting up and operation LAN indicators Figure 9 LAN indicators No Indicator Description 1 LAN speed Steady yellow signal in the event of a LAN transfer rate of 1 Gbit s Steady green signal in the event of a LAN transfer rate of 100 Mbit s Remains dark in the event of a LAN transfer rate of 10 Mbit s 2 ILAN Steady green signal when a LAN connection exists inet Remains dark when no LAN connection exists Flashes green when LAN transfer takes place Depending on the settings in the BIOS the standard LAN connector 1 il may also be used as a service LAN connector You will find further information in the D3032 BIOS Setup Utility for PRIMERGY RX200 S7 Reference Manual RX200 S7 Operating Manual 67 Starting up and operation Indicator on hot plug power supply unit Figure 10 Indicator on hot plug power supply unit 1 Indicator on hot plug power supply unit two colors 800 W power
64. tware from Fujitsu In the event of errors the ServerView Operations Manager refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question This feature is not available for the Japanese market RX200 S7 Operating Manual 15 Functional overview Further information on the CSS concept is provided in the PRIMERGY ServerView Suite Local Service Concept LSC manual on the ServerView Suite DVD 2 For the latest information on optional products provided for the RX200 S7 see the configurator of the server http ts fujitsu com products standard_servers index html for the EMEA market http jp fujitsu com platform server primergy system for the Japanese market System board The features of the system board are described in the D3032 BIOS Setup Utility for PRIMERGY RX200 S7 Reference Manual for the firmware Trusted Platform Module TPM A Trusted Platform Module TPM for safer storage of keys can be implemented as an option This module enables programs from third party manufacturers to store key information e g drive encryption using Windows Bitlocker Drive Encryption The TPM is activated via the BIOS system for more information refer to the D3032 BIOS Setup Utility for RX200 S7 Reference Manual CAUTION When using the TPM note the program descriptions provided by the third party manufacturers You must also create a
65. under Industry Standard Servers Expansion Cards Storage Adapters LSI SAS SCSI RAID Controllers Further information on other SAS SATA RAID controllers e g for operating external SAS SATA hard disk drives or tape drives is available on ServerView Suite DVD 2 under Industry Standard Servers Expansion Cards Storage Adapters LSI SAS SCSI RAID Controllers 18 Operating Manual RX200 S7 Functional overview Accessible drives components The variant with a maximum of four 2 5 inch HDD modules provides a bay for an optical drive The optical drive installed here cannot be replaced during operation USB connectors The two USB 2 0 connectors on the front of the server support activities carried out by the service technician The maximum length of the external cable are three meters Another three USB 2 0 connectors are available on the rear of the device Power supply In its basic configuration the server uses a hot plug power supply unit 450 W or 800 W that adjusts automatically to any mains voltage in the range of 100 240 V As an option the power supply can be expanded with an extra power supply unit to create a redundant power supply If a power supply unit fails the redundant configuration assures continued operation The defective power supply unit can be replaced during operation A mix of 450 W and 800 W PSUs is not allowed In case of mixed configuration CSS LED will be flashing and an SEL entry wil
66. w Operations Manager and the iIRMC S3 Indicators on the drives Optical drive activity indicator Lights up green when the storage medium is being accessed 62 Operating Manual RX200 S7 Starting up and operation Hard disk drive indicators Figure 6 Indicators on the 2 5 inch HDD module 1 HDD BUSY green Lights up HDD in active phase Does not light HDD inactive drive inactive 2 HDD FAULT orange in conjunction with a RAID controller Does not light no HDD error Lights up HDD Faulty or Rebuild Stopped drive defective needs replacing a rebuild process was stopped or the HDD module is not correctly inserted Slow flashing HDD Rebuild the data is being restored after changing a drive Fast flashing HDD Identify Four fast blinks pause HDD Predicted Fault Two fast flashes pause HDD Hot Spare Hot spare drive active The corresponding drive has failed RX200 S7 Operating Manual 63 Starting up and operation Solid state disk indicators Figure 7 Indicators on the SSD modules 1 LED BUSY green Lights up SSD in active phase Does not light SSD inactive drive inactive 2 LED FAULT orange orange in conjunction with a RAID controller Does not light no error Lights up Faulty or Rebuild Stopped drive defective needs replacing a rebuild process was stopped or the module is not corr
67. y JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain such technology should not be exported from Japan or transferred to non residents of Japan without first obtaining authorization in accordance with the above law Harmonic Current Standards This product conforms to harmonic current standard JIS C 61000 3 2 Only for the Japanese market About SATA hard disk drives The SATA version of this server supports hard disk drives with SATA BC SATA storage interfaces Please note that the usage and operation conditions differ depending on the type of hard disk drive used Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive http jp fujitsu com platform server primergy harddisk Operating Manual RX200 S7 Only for the Japanese market Although described in this manual some sections do not apply to the Japanese market These options include CSS Customer Self Service RX200 S7 Operating Manual Operating Manual RX200 S7 Contents 1 lniroducliofs ss ase RE ER RR RE RE IE N N EER RE Eie 11 1 1 Concept and target groups for this manual
Download Pdf Manuals
Related Search
Related Contents
温冷水眠マット - 株式会社TOHO 1.コンクリート住宅の特性と暮らし方 THE GSM EMBEDDED MODEM USER'S GUIDE ーk補助スタンド - 東芝ライテック Kingston Brass HKUS292010DBNL Installation Guide 取扱説明書 PDF manualistica levigatrice verticale tonda Workshop Manual Service WiFi-800 Fog Machine User Manual - Antari Lighting and Effects, Ltd. グレア スーパーホーン Copyright © All rights reserved.