1. and lint e We recommend cleaning the condenser coil at least once per month e Clean the condenser with a commercial condenser coil cleaner available from any kitchen equipment retailer Cleaning the Fan Blades and Motor e If necessary clean the fan blades and motor with a soft cloth e f it is necessary to wash the fan blades cover the fan motor to prevent moisture damage Cleaning the Interior of Unit e When cleaning the cabinet interior use a solvent of warm water and mild soap Do not use steel wool caustic soap abrasive cleaners or bleach that may damage the interior finish e Wash door gaskets on a regular basis preferably weekly Simply remove the door gasket from the frame of the door soak it in warm water and soap for thirty 80 minutes then dry with soft cloth and replace e Check door gaskets for proper seal after they are replaced e Periodically remove the shelves and shelf brackets from the unit and clean them with a mild soap and warm water REFRIGERATION VANTCO User Manual Troubleshooting Compressor is Not Running Fuse blown or circuit breaker tripped Replace fuse or reset circuit breaker Power cord unplugged Plug in power cord Thermostat set too high Set thermostat to lower temperature Cabinet in defrost cycle Wait for defrost cycle to finish Cabinet Temperature is too Warm Thermostat is set too high Set thermostat to lower temperature Airflow is blocked Re arrange products
2. Avoid installation in a high humidity and or dusty area High humidity can cause the unit to rust and may decrease efficiency Dust collected on the condenser coil may cause unit to malfunction Malfunction due to high ambient temperatures humidity or improperly maintained condenser coil will void the warranty e Select a location away from heat and moisture generating equipment High ambient temperatures may cause the compressor to malfunction Malfunction due to high ambient temperatures and humidity will void the warranty REFRIGERATION VANTCO User Manual Electrical e Please ensure that the required voltage is being supplied at all times e The unit should be plugged into a grounded and properly sized electrical outlet with appropriate over current protection Please refer to the electrical requirements on the unit s nameplate e The unit should have its own dedicated outlet e Do not use extension cords e Ensure the unit is not resting on or against the electrical cord e If the unit is not in use for a long period of time please unplug the unit from the outlet e To avoid shock and fire hazards do not plug in or unplug the unit with wet hands e After unplugging the unit wait at least 10 minutes before plugging it back in Failure to do so could Cause damage to the compressor Temperature Controls The temperature controls are preset at the factory to maintain an average temperature of 38 F in refrigerators
3. To maintain a different temperature simply adjust the control knob located inside the unit Temperature ranges from 7 coldest to 1 warmest Setting the temperature control to the coldest setting may cause the evaporator coil to freeze and ice up This will eventually make the cabinet warm which is not recommended Defrost System Refrigerator coils are kept below the freezing point 82 degrees Fahrenheit During compressor down time the evaporator fan continues to circulate air through the evaporator coil This air circulation raises the coil temperature above the freezing point melting any accumulated frost Run off water is drained into the evaporator pan and evaporated Freezer coils are defrosted electrically Automatic defrost timers automatically initiate at pre set intervals and for a pre determined duration REFRIGERATION User Manual VANTCO Loading Product The dividers have already been installed at the factory Please feel free to reposition the dividers as per your need To remove the dividers simply push the divider towards the back wall until the front of the divider is removed from the fixing holes When repositioning the dividers please make sure that the pressure spring is installed properly Operation Maintenance NOTE We strongly recommend that any servicing be performed by an authorized service technician Cleaning the Condenser Coil e For efficient operation keep the condenser surface free of dust dirt
4. AVANTCO ATA ETTE Commercial Bottle Cooler User s Manual 05 2015 Commercial Beer Bottle Coolers JBC 25 JBC 50 JBC 50S JBC 65 JBC 65S JBC 95B JBC 95S Please read the manual thoroughly prior to equipment set up operation and maintenance oe REFRIGERATION User Manual VANTCO Installation Please read this manual thoroughly prior to equipment set up operation and maintenance Important Please Read Before Installation e If the unit has recently been transported on its side please let the unit stand upright for a minimum of 24 hours before plugging it in e Make sure the unit has reached the desired temperature before loading the unit with products e Make sure all accessories are installed shelves shelf clips etc before plugging in the unit e Do not attempt to remove or repair any component of the unit Consult an authorized service technician for servicing repair e Do not hang on doors or stand inside the unit e Please read through this manual in its entirety Cabinet Location Guides e Install the unit on a strong and leveled surface If the surface is uneven the unit may be noisy The unit may malfunction if the surface is uneven e Install the unit in an indoor well ventilated area For best performance maintain 6 of clearance on both sides and the back of the unit at all times Outdoor use may cause decreased efficiency and damage to the unit Avoid direct sunlight e
5. to allow for proper air flow Make sure there is at least four inches of clearance from the fan Low refrigerant levels Contact a service technician to chek refrigerant levels Door is slightly ajar Make sure door is completely closed Warranty Information Units in this manual are backed by a 1 year parts and labor warranty with a 5 year warranty on the compressor For warranty inquiries or service first locate e The model number and cabinet serial number located on the front of the unit or inside the door jamb e The bold number on the service plate located on the front of the unit Next call 1 800 678 5517 Be sure to have the model number cabinet serial number and service plate number available when contacting service technicians This warranty does not apply to and Avantco is not responsible for any warranty claims made on products sold or used outside of the United States RESIDENTIAL USERS Avantco assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in non commercial or residential applications