1. 30 4 3 2 Disabling by other command SVSIeTTIEs cente aea woe RR bi 30 Zenes U 30 31 4 5 1 Zone 1 MIMMEGIALEG 31 4 5 2 Zone 2 bm TT TT 31 4 5 3 600 2510 51 0 ENTER 31 4 5 4 Zone 24h 31 E APR TERI m 31 Maintenance 32 Components TET 32 ern 32 x e 32 1 Introduction Dear customer we desire thank you for buying a CIA product We recommend us to read this manual with attention because it will be very useful in phase of installation and use As CIA customer you make use of a series of services such as the technical telephone assistance on the CIA products Introduction 11 Central unit description The PROTEC4 is a burglary central unit with microprocessor technology to use on the whole of a burglary protection system for habitation and commercial rooms of small and middle dimensions It is to be used with the perimetral protection magnetic sensors and or with the volumetric detectors The alarm can be sounding luminous with the autopowered SA310 siren for outdoor use sounding
2. C401 P Long wires PG12 ATTENTION The PROTECA doesn t allow the connection of the switch contacts for rolling shutters type C778 directly on the terminal boards becouse this central unit hasn t got an impulse counter Use the SCHSW impulse counter board to connect the switch contact for rolling shutters type C778 or use the switch contact for rolling shutters C800 with integrated impulse counter for the direct connection to this central unit 24 VGA 2 3 3 Telephone dialer Installation cccoococooc oR 16 4 CTS Chiave int 12Vec 1S A Sir led key 24H IMM IMM2 RIT USCITA ENTRATA DUR ALL In series to the 24h line 284 25 eS ca A f vo eic 5j 9 hr elo N ENTRATA USCITA y R 4 2 p gt P Q Chove int 12Vce 5 In series to the 24h line SA310 12V 10W lamp 26 VGA 3 Programmation Programmation 3 1 Exiting time regulation The exiting time allows the system user to leave the protected zones after the system enabling During this time a possible activation of the sensors of the all protection zones doesn t activate alarms This timing is adjustable from 5 to 75 seconds by the trimmer situated inside of
3. tension falls 8 9 13Vcc output tension in alarm condition for supplementary indoor sirens and telephone dialer activation 10 11 13Vcc output tension to command the LED on PX SK or KB command systems 10 2 red LED 11 green LED 12 13 24h anti sabotage protection zone NC line immediated 12 14 Zone 1 line immediated 12 15 Zone 2 line immediated 12 16 Zone 3 NC line delayed If the alarm zones are not used the clamps must be arched 22 VGA 2 3 1 Electronic key Installation P uy S w S C7 uy J 1 2 10 e v J Cave 2 12 15 Sir led key 24 IMM2 RIT USCITA ENTRATA DUR ALL Remove the arch NE In series to Eo tl p the 24h line ATTENTION ME Optional E connection ABCOJ EE LED INSERITORE 12 SKI This connection will activate the 24h anti sabotage protection alarm when a false key is inserted in the SKI connector 23 PROTECA User s manual 2 3 2 Reed contacts and volumetric detectors 10 16 Chiave BT 15 Sir led key 24H INM IMM2 RIT USCITA ENTRATA DUR ALL In series to the 24h line a Long wires Short wires C451 Short wi res y
4. the central unit see picture below The exiting time is signalled by the flashing of the green LED USCITA situated on the front panel of the central unit 3 2 Enteringtime regulation The entering time allows the system user to access the protected environments and reach the central unit to disable the system During this time a possible activation of the sensors installed on the zone 1 doesn t activate an alarm cycle This timing is adjustable from 5 to 90 seconds by the trimmer situated inside of the central unit see picture below If an electronic key or any command system is installed externally to the protected environments it s advisable to adjustto minimum this timing 3 3 Alarm time regulation The alarm time duration is adjustable from 30 seconds to 10 minutes by the trimmer situated inside ofthe central unit see picture below Exiting time Entering time Alarm time CecocccoococOOCCcM MM it lt rae 12 15 USCITA ENTRATA 27 PROTECA User s manual 4 Operating 4 1 Front panel description 2 9 C ea Td Se o ee peser ee FE emra SERTE GDN TRELLD ZONE 2 Te ZI 12 7 16 CONTRGLLO 1 2 a AQ RETE P Y T QE ESCLUSIONE USCITA CSEL 96 Tem E wu Key switch released zone status visualization
5. with the piezoelectric SP31 siren for inside use telephonic with the TD81 telephone dialer 1 2 Operating features 4 protection zones 1 delayed 2 immediate 1 24 hours with alarm memory All zones singly excludibles Exit timing adjustable from 5 up to 75 sec Entrance time from 5 up to 90 sec Alarm duration from 30 up to 600 sec Control LEDs main voltage presence exit timing and zone status Visualization of the zones state with central unit switched off Protection fuse on sirens voltage output and service voltage output Sabotage alarm for attempt to exclude zone when the central is switched on Output for connection for controller systems SK KB and SCM electronic key electronic keyboard and magnetic card ALARM MEMORY function for visualization of the zones that caused the alarm e Central unit protection by intermal tamper can be excluded for maintenance According tothe 1 level of 79 2 standard 19 PROTEC User s manual 1 3 Technical features e Operating voltage 230V 10 50Hz Maximum current absorption 140mA e Service output voltage 13V 5 e Maximum current supplied on services output 650mA e Fuse on services output voltage Ftype 1A e Maximum current supplied on sirens output 3A connected to the battery e Sirens output fuse Tipo F 3 15A Maximum current supplied by power supplier AL5 1A e Min operating temperature 542 C Max operating temperature 4
6. 0 2 C relative humidity 933x296 Box protection level IP30 Buffer battery 12V7Ah Fuse on primary of the power supply F type 250mA Fuse on secondary of the power supply F type 1 e Central unit dimensions 280x230x95mm e Insulation class Prestation level 1 PONE DECLARATION CONFORMITY CONSTRUCTOR HiLTRON S r l ADDRESS Circ Est di Napoli compls Lemar 80026 Casoria NA TRADE MARK PRODUCT CODE PROTEC4 PRODUCT DESCRIPTION 4 ZONES BURGLARY CENTRAL UNIT THE PRODUCT RESULTS CONFORM TO THE FOLLOWING STANDARDS REQUIREMENTS STND SPECIFICATION TITLE EN50081 1 EMISSION STND Part 1 residential commercial and light industry EN50082 1 IMMUNITY STND Part 1 residential commercial and light industry EN60335 1 SAFETY OF HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES CONFORMITY WAS BASED ON EMC PERFORMANCE TESTS CONDUCTED ON SAMPLE RUNNING IN THE DESIGNED WORKING CONDITIONS AS FOR ITS FUNCTIONAL PROJECT IT MEETS 89 336 EEC AND 73 23 EEC REQUIREMENTS DATE 21 May 1999 COMPA ANAGEMENT 20 VGA 2 Installation Installation 2 1 General instructions e Do not install the device at places exposed to the bad weather or to the extreme temperatures e The central unit is protected from the opening but the installation in a safe place is a greater protection ofthe device e Fora strong and safe fixing it needs making s
7. 28 Allows to enable disable the system If there s an electronic key or another command system this switch has always to be turned on the INSERITO position RETE red LED on off presence of main supply absence of main supply ALLARME yellow LED on during the entering time or in alarm condition blinking ALARM MEMORY USCITA green LED on system disabled blinking during the exiting time off system enabled MEMORIA ALLARME button ALARM MEMORY visualization pressed On system disabled by pressing this button the blinking zones status control LEDs 9 O indicate the ALARM MEMORY i e the zone that caused the alarm 24h zone status control LED on zona aperta off zona chiusa blinking zona autoesclusa Zone1 zone 2 zone 3 status control LED on zona aperta off zona chiusa blinking ALARM MEMORY with the button pressed Zones exclusion inclusion buttons On system disabled it is possible to exclude a zone by pressing the relative button the LED upstanding the button starts blinking The zone protection willnot be included during the system enabling VGA 4 2 System enabling 4 2 1 Enabling by the front panel key switch e Verify thatthe zone status LEDs 9 and O are turned off Operating If they re switched on it s necessary to close the doors and windows relative to the zone signalled opened It s also possible that the zone signall
8. S C VN o 2 TT SGA PROTECA A zones burglary central unit USER S MANUAL PROTECA User s manual Index Chapter 1 2 Chapter 2 Chapter 3 Chapter 4 4 1 4 2 4 3 4 4 4 5 4 6 Chapter 5 18 Introduction 19 Central unit desclipOL 19 5 2 T c 19 Technical T6 RUSS an 20 Installation 21 General MIS UC HORS 21 POWO SUPPI H 21 OAS CONS os rC EE W 22 2 51 KOY 27727 23 2 3 2 Reed contacts and volumetric detectors 24 25 23A OVENS RE Um T TER 26 Programming 27 Exiting time regulation NE 27 mue E 27 Alani ime regulae 27 28 CS SON RENTE E 28 System enabling MN RR m 29 4 2 1 Enabling by the front panel 29 4 2 2 Enabling by other command system 2 49 29 SUS 221 30 4 3 1 Disabling by the front panel
9. d Ensure of its efficient charge state measuring the tension by a volt meter after disconnecting the main power supply from the AL5 power supplier battery charger by the sectioning switch Also in case of changing of the lead battery it s necessary to disconnect the main power supply from the AL5 power supplier battery charger to avoid that the entire system burden on it Don t connect on 13Vcc services power supply output of the central unit clamps 5 and 6 12V a load beyond 650 After connecting the central unit and the siren batteries it s possible to power on the system by the sectioning switch connected on the AL5 The RETE LED signals the effective presence of the main voltage The PROTECA and the AL5 don t need the ground connection but for safety reasons and for the respect of the laws in vigor we suggest to make and test a ground connection for the all devices that need it 2 3 9 Connections 12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 int Sir Led kev 7 1348 MM2 USCITA ENTRATA DUR ALL 1 2 Output in series to the key switch of the front panel Cutto connect PX SK or KB command systems 3 4 13Vcc output tension on system enabled for the telephone dialer enabling 5 6 13Vcc regular output tension for volumetric detectors telephone dialer etc ATTENTION Maximun current supplied 650mA 7 8 13Vcc output tension to recharge the autopowered siren In alarm condition this
10. ed opened could be the one relative to the volumetric detectors in this case the exiting time will allow to exit the protected area without activating the alarm e Turnthe key switch in the ON position The green LED USCITA starts blinking indicating the exiting time in which to leave the protected areas e When the exiting time is finished the green LED USCITA turns off indicating that the system is enabled 4 2 2 Enabling by other command system If an electronic key system a proximity key system or an electronic keypad system is installed outside of the protected areas it s necessary to leave the key switch 9 ALWAYS in the ON position All the SKI connector for the electronic key the PXR reader for the proximity key and the KBC KBM and KBT keypads have two LEDs one green and one red indicating the central unit status see table beside Toenable the system e Verify thatthe red LED is turned off If it s turned on it s necessary to close the opened doors or windows relative to the zone that is signalled opened in the central unit e Insert the electronic key or approach the proximity key to the reader or digit the code on the keypad ThegreenLED turns off indicating that the system is enabled GREEN RED LED LED ON FLASH OFF GREEN System System System LED disabled 98901609 enabled Excluded zone RED Opened Alarm Closed LED zone s memory zones Exitin
11. g BOTH amie 29 PROTECA User s manual 4 3 System disabling 4 3 1 Disabling by the front panel key switch Opentheentering door TheyellowLED ALLARME starts blinking The alarm will not activates immediately becouse the entering door is usually protected by the delayed zone 1 the entering time will allows to reach the central unit to disable the system e key switch in the DISINSERITO position 4 3 2 Disabling by other command system If an electronic key system a proximity key system or an electronic keypad system is installed outside of the protected areas it s necessary to leave the key switch 9 ALWAYS in the INSERITO position All the SKI connector for the electronic key the PXR reader for the proximity key and the KBC KBM and KBT keypads have two LEDs one green and one red ER RED indicating the central unit status see table LED beside To disable the system e Verify that the red LED is turned off If blinking it means that an alarm was happened precisely on the zone signalled in the central unit with the zone status LED blinking after having pressed the MEMORIA ALLARME ON FLASH OFF outon GREEN System System LED disabled enabled e Insert the electronic key or approach Aes cone the proximity key to the reader or digit RED Opened Alarm Closed the code on the keypad LED zones Exiting e green LED turn
12. s on or blinks if ERR time there s an excluded zone indicating thatthe system is disabled 30 VGA 4 4 Zones exclusion Operating From the front panel it is possible to exclude the zones 1 2 and 3 simply by pressing the zone related exclusion button The exclusion of the zone is visualized by the flash of the zone related LED 4 5 Zones operating The four protection zones have different operating characteristics 4 5 1 Zone 1 immediated Onsystem enabled the opening of the NC line immediately activates an alarm cycle Thealarmis active for the alarm time setted par 3 3 e This zone is excludible from the front panel 4 5 2 Zone 2 immediated Onsystem enabled the opening of the NC line immediately activates an alarm cycle e Thealarmis active for the alarm time setted par 3 3 e This zone is excludible from front panel 4 5 3 Zone3 delayed e Onsystem enabled the opening of the NC line activates an alarm cycle after the entering time setted par 3 2 active for the alarm time setted par 3 3 e This zone is excludible from the front panel 4 5 4 Zone 24h immediated Onsystem disabled the opening of the NC circuit activates immediately an alarm cycle of few seconds then the zone autoexcludes till the line is opened Onsystem enabled the opening of the NC circuit activates immediately an alarm cycle cycle is acti
13. ure the wall surface is plane Fixing the device by the four fishers included in the central unitand no replacing them with others of more small size Fixing the central unit at a height that allows an easy access to the frontal panel The central unit must be connected with an alarm system according to 79 3 Standard or similar 2 2 Powersupply It s important to know that the entire system is powered exclusively by the 12V 7 5Ah lead battery inside of the burglary central unit the lead battery is constantly in charge by the AL5 power supplier battery connected to the 230V main power supply WARNING The main power supply 230Vac has to be connected to the power supplier battery charger AL5 by two 1 5 double isolation wires coming from a sectioning switch i e a magneto thermic protection switch used exclusively for the burglary central unit Inside of the central unit positioning orderly the two wires locking them by wrappers Switch A Speman m 2 CE 230V 50 2 main power supply 21 PROTEC User s manual When the installation is finished it needs to connect the red black conductors equipped with faston coming from the AL5 power supplier to the battery Be careful about connection polarity Red positive of the battery Black negative of the battery so that no cause great damages to the connected devices ATTENTION The 12V7Ah battery must always be connecte
14. ve for the alarm time setted par 3 3 4 6 Alarm memory On system disabled pressing the MEMORIA ALLARME key the zone control LEDs indicate the zone that caused the previous alarm 31 PROTEC User s manual 5 Maintenance 5 1 Battery It is advisable to check the battery connected to the AL5 power supplier battery charger and the battery inside ofthe self powered sirens 5 2 Cleaning Forthe central unit cleaning use only a soft and humid cloth No use absolutely diluents and abrasive sponges 5 3 Fuses F1 Sirens output Ftype 3A F2 Servicesoutput 1A 32 299ADE 1 01