Anaheim Scientific H100 Wide Range Light Meter

image

Contents

1. For unknown light types we recommend you use Tungsten Note The LCD display will indicate the selected lighting type with the following symbols Tungsten Fluorescent No symbol 4 Select the max range by using the Range Button 4 6 Fig 1 a If the main display shows it indicates overload condition Select the next higher range b Ifthe main display shows _ _ _ _ itindicates out of range Select the next lower range c To get the most accuracy from this unit use the range that will both display the measured value with the highest resolution 5 Position the Light Sensor 4 13 Fig 1 directly under the light source 4 3 Zero Adjust a Cover the Light Sensor 4 13 Fig 1 using the Sensor Cover 4 14 Fig 1 Do not remove the Sensor Cover b Setto 40 00 Lux range other ranges need not be zeroed c Pushing the Zero Button 4 7 Fig 1 will zero out the LCD display d Upon completion remove the sensor cover 4 4 Data Hold a During measurements press the Hold Button 4 3 Fig 1 The data on the LCD display will be held and the HOLD symbol will be displayed b Push the Hold Button again to release the data hold function and return the display to show current readings 4 5 Peak Hold a During a measurement press and hold the Hold Button 4 3 Fig 1 for at least 3 seconds The mete will now only display and hold the largest measur
2. the PC serial port Visit www anaheimscientific com to see any available downloadable software for your instrument Meter PC 9W D Connector Center Pin 3 5 mm jack plug Ground shield resister The 16 digit data stream will be displayed in the following format 015 014 013 012 011 010 D9 D8 D7 D6 05 D4 D3 D2 0100 Each digit indicates the following status D15 Start Word D14 4 When send the upper display data 1 D13 When send the lower display data 2 D12 amp D11 Indicator for Display Lux 15 Fc 16 10 Polarity 0 Positive 1 Negative Decimal Point DP position from right to left 09 0 1 1 2 2 3 3 DP Display reading 01 LSD 08 MSD Example If the display reading is 1234 D8 to D1 then D8 to D1 is 00001234 DO End Word RS 232 Setting Baud Rate 9600 Parity No Parity Data bit 8 Data bits Stop bit 1 Stop bit 7 Battery Replacement 1 When the LCD display shows the ow battery symbol Itis necessary to replace the battery The specifications listed for this instrument do not apply when the low battery symbol is displayed 2 Open the Battery Compartment 4 11 Fig 1 by first loosening the Battery Cover Screws 4 17 Fig 1 3 Replace the batteries with good batteries noting the correct polarity Replace Battery Compartment 4 11 Fig 1 and Battery Cover Screws 4 17 Fi
3. 000lux Unitof Measurement lux or Foot Candle fc Measurable Lighting Sources Tungsten Fluorescent Sodium or Mercury Lamps Sensor Photo diode amp color correction filter spectrum meets C LE Cosine correction factor standards Display values Unit Range In Range Display Resolution 40 0 to 40 00 Lux 0 01 Lux m T 40 0000 00000 4 0 to 3 720 Fc 0 001 Fc i enc 4 000 335 to 3 720 Fc 1 40 000 930 to 37 200 Fc 10 Fc Accuracies Range Accuracy 40 jj T 3 rdg 4 0 5 96 F S 40 000 400 000 100 000 Lux 3 rdg 0 5 F S 4 40 fc 3 rdg 0 5 F S foot candle u 4 000 40 000 9 300 3 rdg 4 0 5 F S Zero Adjust 40 00lux range only Peak Hold Displays peak value Data Hold Display freeze Memory Saves MAX or MIN values with recall Power Off Auto or manual control Over and Under Range Indicator Over range indicator top of the display Under range indicator _ _ bottom of the display 5 Data Output RS 232 Serial data output Operating Environment 32 to 122 F 0 to 50 C 8096 Power Supply 6 Pieces of DC 1 5V Batteries UM4 AAA or equivalent Weight approx 0 79lbs 3579 Dimensions approx Main instrument 6 9 x 2 7 x 1 7 174 x 68 x 42mm Sensor probe 3 5 x 2 4 x 0 8 89 x 61 x 20mm Included Accessories Instruction m
4. A SCIENTIFIC Division of BK PRECISION LIGHT METER 401490 4 90140 00 400 0 LUX 4 light type AS Model H100 INSTRUCTION MANUAL Models H100 Light Meter ce Table of Content 1 Product Introduction mem 3 1 1 Features BER HER DEE DEE DEE DEE DEE DEREN DEN DEE DEN DEN HEN HEN DEN 3 1 2 ADDICTIONS nee 2 Safety Information eene d 2 1 CAU mcus ext ca van n n nar cer 4 2 2 Safety Symbols NEN BEE NEN DEN BEE DEE DEN BEN EEE A HEN RN 4 3 Specifications nat a D 4 Operation Instructions sss sss sun sun nun nun nna nun nnn nnn 4 1 Unit Diagram sea 4 2 Measuring Procedure 4 3 Zero AdjUSt ae een 4 4 Data Hold ion 25 Poss Hold css ote etd dr rreren nne 4 6 Data Record tt W OO CO CO CO NN 5 Auto Power Off Disable sss sss seen 9 6 RS232 PC Serial Interface Information 10 7 Battery Replacement smc seems LL 8 Service Information s sss sss sss eem 12 9 Warranty Information eene 13 To see all available accessories and downloadable software please visit www anaheimscientific com 1 Product Introduction 1 1 Features Two year warranty Large LCD display with bar graph Wide measurement ranges 40 00 400 0 4 000 40 000 400 000lux Display resolution 0 04lux to 100lux 0 01ft cd to 10ft cd lux or foot candle unit selection 4 light ty
5. anual battery carrying case Accuracies for lux over 100 000 and fc over 9 300 are not specified Readings are for reference only Note Accuracy tested by a standard parallel light tungsten lamp of 2856 K degree temperature Specifications and information are subjectto change without notice Please visit www anaheimscientific com for the most current product information Spectrum for Light Sensor H100 CIE 60 40 20 wil 410 430 450 470 490 510 530 550 570 590 610 630 650 670 690 710 730 750nm 4 Operating Instructions 4 1 Unit Diagram Display Power Button Hold Button REC MAX MIN Button Lux F c Button Range Button Zero Button Light Source Button Light Sensor Input Socket 4 10 Stand 4 11 Battery Compartment 4 12 RS232 Socket 4 13 Light Sensor 4 14 Sensor Protective Cover 4 15 Light Sensor Plug 4 16 LCD Display Contrast Adjust 4 17 Battery Cover Screw 4 18 Tripod Screw Mount 4 2 Measuring Procedure 1 Push the Power Button 4 2 Fig 1 to power on the instrument The meter will perform a short self test before measurements can be taken 2 Select the desired unit of measurement by pressing the Lux Fc Button 4 5 Fig 1 The display will indicate the selected unit of Lux or Ft cd 3 Determine the lighting type Tungsten Fluorescent Sodium or Mercury lamp by pressing the Light Source Select Button 4 8 Fig 1
6. ed value along with the Peak HOLD indicator b To clear the peak value momentarily press the Hold Button 4 3 Fig 1 c To turn off the Peak Hold function press and hold the Hold Button 4 3 Fig 1 for at least 3 seconds 4 6 Data Record a The data record function records the maximum and minimum readings Press the REC Button 4 4 Fig 1 to start the data record function b With the REC symbol on the display momentarily pressing the REC Button 4 4 Fig 1 will toggle between Max and Min recording c To exit the memory record function press and hold the REC Button 4 4 Fig 1 for at least 3 seconds d Note To delete the displayed value while recording just press the Hold Button 4 3 Fig 1 until the display clears the data leaving the REC symbol 5 Auto Power Off Disable This instrument has a Auto Power Off function that can prolong battery life The meter will shut off automatically if none of the buttons are pressed in approx 10 min To disable this function select the memory record function during a measurement by pressing the Button 4 4 Fig 1 6 RS232 PC Serial Interface Information This instrument has RS232 PC serial interface via a 3 5 mm terminal 4 12 Fig 1 The data output is a 16 digit stream which can be utilized for user s specific application A RS232 lead with the following connection will be required to link the instrument with
7. g 1 Ensure the cover is securely fastened 8 Service Information Warranty Service Please return the product in the original packaging with proof of purchase to the address below Clearly state in writing the performance problem and return any leads probes connectors and accessories that you are using with the device Non Warranty Service Return the product in the original packaging to the address below Clearly state in writing the performance problem and return any leads probes connectors and accessories that you are using with the device Customers not on open account must include payment in the form of a money order or credit card For the most current repair charges please visit www anaheimscientific com and click on service repair Return all merchandise to Anaheim Scientific with pre paid shipping The flat rate repair charge for Non Warranty Service does not include return shipping Return shipping to locations in North American is included for Warranty Service only For overnight shipments and non North American shipping fees please contact Anaheim Scientific Anaheim Scientific 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com 714 921 9095 Include with the returned instrument your complete return shipping address contact name phone number and description of problem 9 Limited Two Year Warranty Anaheim Scientific warrants to the original purchaser that its products and the co
8. mponent parts thereof will be free from defects in workmanship and materials for a period of two years from date of purchase from an authorized Anaheim Scientific distributor Anaheim Scientific will without charge repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date in the form of a sales receipt To obtain warranty coverage in the U S A this product must be registered by completing the warranty registration form on www anaheimscientific com within fifteen 15 days of purchase Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed Anaheim Scientific shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some states do not allow limitations of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may have other rights which vary from state to state Anaheim Scientific 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com 714 921 9095 Anaheim Scientific 22820 Savi Ranch Parkway Yorba Linda CA 92887 U S A www anaheimscientific com Printed in Taiwan Ver 1 01 1111 2011 Anaheim Scientific Corporation
9. pe select Tungsten Fluorescent Sodium or Mercury Sensor meet C I E spectrum 2 filters Data hold Record max min DC 1 5V battery UM 4 AAA x 6 Longer battery life compared to 9V 1 2 Applications Science Experiments Photography Manufacturing Agriculture Artistry 2 Safety Information A Read the following safety information carefully before attempting to operate or service the meter Only qualified personnel should perform repairs or servicing not covered in this manual 2 1 Cautions m DO NOT submerge the products mentioned in this manual in water or any other types of liquids E This product is not designed for use in medical applications The product can only be used to measure body temperature simply for reference 2 2 Safety Symbols Dangerous refer to this manual before using the meter C Conforms to requirements of European Union and European Fare Trade Association EFTA lt Battery level is low amp Don t dispose this product as unsorted municipal waste This instrument conforms to the following standards EN61326 Electrical equipment for measurement control and laboratory use IEC61000 4 2 Electrostatic discharge immunity test IEC61000 4 3 Radiated radio frequency electromagnetic field immunity test IEC61000 4 8 Power frequency magnetic field immunity test 3 Specifications Display 5 Digit LCD with bar graph indicator Measurement Ranges 40 00 400 0 4 000 40 000 400