LOOP-AM MODEL 3440-C Access DCS

image

Contents

1. 22454 Alarm Unit Alarm Type Alarm Description Alarm cut off 0 Slot no work 1 Slot start 2 Clock loss 3 Primary start 4 Redundant loss 5 Backup switch 6 Power failure 7 Redundant checksum error 8 Controller Fan failure 9 TSI map switch 10 LINK PROTECTION ALARM REDUNDANT INSERT ALARM REDUNDANT UNSYNC ALARM REDUNDANT TO PRIMARY ALARM CARD TYPE MISMATCH ALARM LINK ID MISMATCH ALARM POWER CONSUMPTION ALARM SSM CLOCK SWITCH ALARM RAI Remote Alarm Indication 21 AIS Alarm Indication Signal 22 LOS Loss of Signal 23 E1 card LOF Loss of Frame 24 BPV Bipolar Violation 25 ES Error Second 26 UAS Unavailable Second 27 CSS Control Slip Second 28 T1 card YEL Yellow Alarm 21 AIS Alarm Indication Signal 22 30 Chapter 3 Operation Alarm Type Unit Alarm Type Alarm Description red LOS Loss of Signal 23 LOF Loss of Frame 24 BPV Bipolar Violation 25 ES Error Second 26 UAS Unavailable Second 27 CSS Control Slip Second 28 Note If Redundant Loss and Redundant Insert are a pair the alarm condition will be cleared when Redundant Insert occurs after Redundant Loss If Slot no work and Slot start are a pair the alarm condition will be cleared when Slot start occurs after Slot no work 31 Chapter 3 Operation 3 3 2 Reports For DS1 line receiver Loop AM has three sets of performance reg
2. Protection Working Port Port 1 Port 2 Port 3 Port 4 Slot B FE1 FEL Slot C D FOM Slot 1 2 QuadE1 Slot 3 4 QuadE1 QuadE1 Slot 5 6 3 3 52 Ju lt lt ESC key ignore and return ENTER key accept change gt gt Function Option Default ForceSwitch NO ForceSwitch NO 159 Chapter 10 Appendix D LOOP AM3440 C ALARM TRAP INFORMATION 10 APPENDIX D LOOP AM3440 C ALARM TRAP INFORMATION 10 1 Trap definition trap MIB localTrap TRAP TYPE ENTERPRISE loop AM3440 C VARIABLES ccAlarmQueueString ccAlarmType ccAlarmModel ccAlarmSlot ccAlarmPort ccAlarmSeverity DESCRIPTION Local alarm trap n 3 removeTrap TRAP TYPE ENTERPRISE loop AM3440 C VARIABLES ccAlarmQueueString ccAlarmType ccAlarmModel ccAlarmSlot ccAlarmPort ccAlarmSeverity DESCRIPTION Local alarm trap remove 9 161 10 2 BR NN Chapter 10 Appendix D LOOP AM3440 C ALARM INFORMATION ccAlarmModel Card model type Number Card Type fe1 ft rs232 8 oct rt b v35 x50 dtu 6 dtu 10 mdsl Is optical em fxs router fxo afr e1 afr t1 magneto quad e1 quad t1 mdsl a v35 a gshdsl 4 gshdsl 2 g703 mquad e1 mquad t1 dry contact fom router a controller conference tri e1 tri t1 tdmoe 8DBRA sdte x21 a v36 a rs422 a eia530 rs449 a unknown Card Type Description 1 channel E1 1 channel T1 8 cha
3. DU DLT ted To eto 37 4 6 VERIFYING LOOP A M OPERA TIONS nr AU ee vedios Ure ved Ton este 37 4 6 1 QUICK Test A ete ERR e I EN se 37 4 6 2 SUDSIITUTIOR s iri be LE Big SOA ee RE 38 4 6 3 Using Loopback Pl gs i Set reve eie E stag naps teens Antenne 38 4 6 4 Using Bert Test SOL sc ue eet e Seow test tended eet et e He eie ee ert eee AE an 38 FRONT PANEL OPERATION s ee seus eoe eonun eva oa vetu a t ee ee Vno eve eoa toe voa Ue idea de 39 5 1 REFER TO AM3440 LCD SEPARATE 0000 39 6 TERMINAL OPERATION 40 6 1 MENUTREE E E E Rudi rte dede EA 41 6 2 MAINIMENUS eerie act cos ue ies 42 6 2 1 System Configurdtion eiae eiie pr ritiene giis HR beads 42 6 2 2 Clock Source Configuration etie ire ti reete tee ete ee E HP E eret eh ere et 46 6 2 3 Alarm Queue Summd ry idealer ter rh eei Fb re tere ere HERE eere des 49 6 2 4 Information Summary ii tatis eee et need erbe i Reb ies eet 49 6 2 5 Redundant Board Information ss 50 6 2 6 Performance Repoti e i a E RE RAO NER FRE FL net HERE RH Tate 51 6 2 7 sai aie pea Dep ie c e
4. Slot 1 2 QuadE1 Slot 3 4 QuadE1 QuadE1 CIRCUIT LINE NONREV 1 1 NONREV DISABLE Slot 5 6 Protection Working Port Port 1 Port 2 Port 3 Port 4 Slot A B FE1 FE1 Slot C D FOM Slot 1 2 QuadE1 Slot 3 4 QuadE1 QuadE1 Slot 5 6 z 3 eL 3 2 3 3 gt gt Change configuration Y N Note to save please use V command Force Switch Configuration The protection Setup must be set before the status setup Go to Controller Menu S System Setup Q QDS1 1 1 Protection select Status and press Enter The Status menu is to setup the ForceSwitch for each protection pair and ports LOOP AM3440 C QDS1 1 1 Protection 15 19 15 08 02 2011 gt gt Select Setup Status 158 Chapter 9 Appendix C QDS1 1 1 Protection The Status menu it is to setup the force switch function to the assigned port of assigned protect pair LOOP AM3440 C QDS1 1 1 Protection 17 00 00 08 02 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Protect Pair Master Backup Port 1 Port 2 Port 3 Slot A B FE1 FEL Slot C D FOM Slot 1 2 QuadE1 _ Slot 3 4 QuadEl QuadEl ForceSwitch NO NO Slot 5 6 2
5. SP EDNA SEN as se Reine Ord Nears La lOSMAN HSE ER E E SSS eee 4th Nearest 15Min os Sess Ses RAA E we ey Se eee See eremum es Valid 15 Min Intervals in Current 24 Hour Interval 0 AS 5 SES BES SES SDM CSS Current HS ESS MESSE ce BSS Oe SSSR Ress 07 2 9 2009 4 st Se See 00422421002 OO tee SSRIS Seas Seas comes 09 21 2002 ERAS Ose eS crm SSeS Se SS SaaS ESS See 07 20 2002 Reet Re ceo B EESGNPVGMERREBRADERERUODPEPICR Eee TEUER 0 19 2002 4 07 19 2002 LITRES UM TRE SSeS Eee ume Eme CHAT 24002 isin SSeS eh ESS SSSR SHS SES eue lt lt TAB key to show Performance Report gt gt lt lt ESC key to return to previous menu SPACE key to refresh gt gt 16 30 16 07 24 2002 SLOT D ATM FR El Port 1 Hour Perf Report LINE Valid Seconds in Current 15 Min Interval 33 seconds ES UAS BES SES DM Current 15 Min Interval x 23 0 0 0 1st Nearest 15 Interval 2nd Nearest 15 Interval 3rd Nearest 15 Interval 4th Nearest 15 Interval Valid 15 Intervals Current 24 Hour Interval 0 ES UAS BES SES DM
6. LINE Network i ha Qt ed FAR END SEE Y Report available and can be cleared by admin terminal command Y N C No clear Report available but counts cannot be cleared by the user Report not available 32 Chapter 3 Operation 3 4 LED Operation The front of the AM3440 C has LEDs for operation and error indications The indication can be in one or more colors Note that when powering up and self test is in progress the unit front panel LEDs are also used to indicate fault conditions Table 3 8 Front Panel LED Table DS1 HDSL DTE ATM FR Got Indian POWER Off Power off Green Power on and operational Primary CPU Power Off Power off Green Power on and operational Active CPU fails Fasting Green Normal Normal or alarm disable Alarm Alarm Redundant cr Power off P Power U pr Green SIE e on and act as redundant CPU Active Noma Normal Redundant CPU board is synchronizing to Alarm Red Ol primary CPU board gt The Scion ten is done Red Redundant version is different with Primary NOTE Active led is used to identify primary CPU If the color of Active led is flashing green then this CPU is primary Of Noo signal or port not equipped Normal 4E1 T1 interface in sync Green In master mode as protection function is enable Red Alarm 4E1 T1 interface is unsync Flashing Red ee id ro Flashing Green slowl
7. 6 6 3 Unit Line Availability Under Port Menu press A to view the line availability as the following screen shows SLOT A MQuad El PORT 2 Port Line Availability 10 23 56 10 27 2004 Line Availability during Last 24 Hour Valid Seconds 849 seconds Available Seconds 849 seconds Unavailable Seconds 0 seconds Line Avaliability 100 0 lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 141 Chapter 6 Terminal Operation 6 6 4 Unit Configuration To view the unit configuration press C from Port Menu then the screen will show as below SLOT A MQuad El PORT 2 Port System Setup 10 24 14 10 27 2004 FRAME ON CODE HDB3 CRC ON RAI ON AIS FRAMED CAS OFF SIGNALLING TRANS CGA NORM 005 BUSY FDL OFF Sa bit Sa4 IDLE D5 Protected DISABLE Master INTF 120 Ohm lt lt ESC key to return to previous menu SPACE bar to refresh gt gt Note FDL can be enabled in a maximum of 2 ports 6 6 5 Unit Status Press I from Port Menu to show the screen of Unit Status as below SLOT A MQuad El PORT 2 Port Status 10 24 27 10 27 2004 LENE LOS NO LOF NO RCV AIS NO RCV RAI NO XMT AIS NO XMT RAI NO BPV ERROR COUNT 9407 ES ERROR COUNT 4 TEST PATTERN TRANSMITTED OFF NEAR END LOOPBACK OFF lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 142
8. einge dea 30 Table 3 6 Performance Parameter List 32 Table 3 7 Performance Report Options seine 32 Table 3 8 Front Panel LED Table 051 HDSL DTE 33 Table 3 9 Error Message Table ocine egi decet diee bd De ede Lie cet E CEA De c ede 36 Table 6 1 Power Consumption sise 46 Table 13 1 Power Consumption of AM3440 C Plug in Cards 182 GB ES DK FIN PL CZ SK SLO GR PRC Bitte f hren Sie das Ger t am Ende seinerLewbensdauer den zue Verf gung stehended R ckgabeund Sammelsystemen zu At the end of the product s useful life please dispose of it at appropriate collection points provided in your country Une fois le produit en fin devie veuillez le d poser dans un point de recyclage appropri Para preservar el medio ambiente al final dela vida til de su producto depositelo en los laguares destinado aello de acuerdo con la legislaci n vigente No final de vida util do producto por favor coloque no ponto de recolha apropriado I Onde tutelare l ambiente non buttate l apparecchio trai i normali rifiuti al termine della sua vita utile ma portatelo presso i punti DI RACCOLTA specifici per questi rifiuti previsti dalla normativa vigente Wi1j raden u aan het apparant aan het einde van zijn nuttige levensduur niet bij hey gewone huisafval te deponeren maar op de dearvoor bestemde adressen Nar produktet er udtj
9. sees suse tasse 151 8 1 INTRODUCTION Rae Ie einsdem desine 151 8 2 INBAND MANAGEMENT SETUP PROCEDURE eee een en een en 6 ASAE enne 152 9 APPENDIX C QDSI 1 1 PROTECTION 0 0 00 400 testet thats tastes tosta suse ta sens ta sesto sees suse 154 9 1 INTRODUCTION tercie eprehenderit hee 154 9 2 SETTING UP CIRCUIT PROTECTION joi ettet extet eerie rie ee eit iere ive eee e 154 9 2 1 Connecting the Y Box to the AM 3440 C Shelf ss 154 9 2 2 Quad El Gard Loc lion x s e e intl entente ene endet eite cs 156 9 2 3 Settiig up a MI IO0 MONO i EH tede eee nul Ait espe qe 156 9 2 4 Step by Step Quad Card Circuit Protection Setup sense 156 9 3 SETTING UP LINE PROTECTION etit ere eet iei ee ede i bere eene 157 9 3 1 Step by Step Quad EI Card Line Protection Setup 156 10 APPENDIX D LOOP AM3440 C ALARM TRAP INFORMATION eeeeeee tenen seen tenens 161 TO 1s TTRAPIDEEINITION eene tetro tee p menge edited cente tene eee pete ese 161 10 2 CCALARMMODEL CARD MODEL TYPE certet tenerte eset Pene aede nean degere ii en annees sce 162 10 32 CCADARMSEOT SLOT INDEX entente php e e EAE ere in bt ee ete it 163 10 4 CCADARMPORT PORT INDEX em peret tiere i eed reste ees 163 10 5 CCALARMTYPE lt 20 CONTROLLER ALARM ss 163 10 6 COADARMLYPE UNIT ALARM
10. 3 ffs g RE A 7 QD 2 LC CJ gt 2 Plug in 4 8 x Ex z Ifo o ol Tx LineTx BTx 2 3 A Tx LineTx 3 4 Cy C OJ 0 LU A Rx LineRx B Rx A Rx LineRx B Rx A BTx Figure 9 1 Connection for AM3440 C and Y BOX with BNC connectors If you are using the RJ48C type Y BOX connect it to the Loop AM3440 C as shown in Figure 9 2 below For illustration purposes only Port 9 is protected in this sample diagram To protect other ports you must connect them in a similar manner Plug In 3 MA PU IIA Mini Plugin D Plugin 5 Plug In 4 Loop W A LINE9H A LINEIOB A LINEIIB A LINEI2B A LINEI3B A LINEI4B A LINEISB A LINEI6B Ade do d RR Ro RR RR R A LINEIB A LINE2B A LINE3B A LINE4B A LINESB A LINEGB A LINE7B A LINESB Figure 9 2 Connection for AM3440 C and Y BOX with RJ48C connectors NOTE Cable connections between the RJ48C connectors on the Y Box and RJ48C connectors on the AM3440 C must be parallel ie Pin 1 gt Pin 1 Pin 2 Pin 2 Pin 4 4 and Pin 5 gt 5 155 Chapter 9 Appendix C QDS1 1 1 Protection 9 2 2 Quad E1 Card Location In our sample setup we installed a Quad E1 card in Slot Z3 We will use it as a Master It will be the working line We also installed a Quad E1 card
11. 9 Receive Clock Return DCE Table 2 10 X 21 V 11 and DB15 DTE Port Pin Definition 21 Signal Unassigned 4 qu 21 Chapter 2 Installation Table 2 11 RS232 DB25 DTE Port Pin Definition 21 Cable Shield 6 Data Set Ready DCE 7 Signal Ground 8 Data Carrier Detect DCE 9 Unassigned 210 Unassigned 21 Unassigned 12 Unassigned 13 Unassigned 14 Unassigned 16 Unassigned 9 Unassigned Unassigned 23 Unassigned 22 Chapter 2 Installation Table 2 12 DB25 Mini Quad E1 Pin Definition 1 TransmitDataTIP_Portt 2 Receive DataTIP_Portt 0 3 Unassigned 4 Transmit Data TIP_Port2 Z 5 Receive Data TIP_Pot2 6 Unassigned 7 Transmit Data TIP_Pot3 0 8 Receive Data TIP_Pot3 00 9 Unassigned 10 Transmit Data TIP_Port4 11 Receive Data TIP_Pot 4 0 12 Unassigned fe 19 14 TransmitDataRING Portt 0 2 15 ReceiveDataRING Porti 16 Unassigned 0 17 TransmitDataRING Port2 18 Receive Data RING Port2 0 9 Unassigned 20 TransmitDataRING Port3 2 ReceiveDataRING Pot3 0 00 Unassigned ars 28 Transmit Data RING_Port4 Z 24 Data RING_Port4 25 Unassigned
12. EP AV AV k LOOP AM MODEL 3440 C Access DCS MUX USER S MANUAL LOOP TELECOMMUNICATION INTERNATIONAL INC 8F NO 8 HSIN ANN RD SCIENCE BASED INDUSTRIAL PARK HSINCHU TAIWAN Tel 886 3 578 7696 Fax 886 3 578 7695 2011 Loop Telecommunication International Inc All rights reserved 6 OCT 2011 Version 22 CAUTION Only qualified service personnel shall install and maintain the system This equipment must be connected to an earth socket outlet which has a permanent connection to protective earth with a cross sectional area of not less than 2 5 mm Ensure protective earthing connected before install uninstall telephone wires Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines Pr cautions Seul le personnel qualifi peut installer et entretenir le mat riel L quipement doit tre connect la prise de terre qui doit avoir une connexion permanente la terre de protection avec une section de fil sup rieure 2 5 mm2 S assurer que la terre de protection est branch lors de l installation ou d sinstallation des fils t l phoniques Ne jamais installer les fils du t l phone pendant un orage
13. ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Enable Password YES Change Password NO lt lt Press ESC key to return to previous menu gt gt LOOP AM3440 C 18 15 43 11 25 2008 59 Chapter 6 Terminal Operation 6 2 7 4 TSI Map Setup Controller Menu gt S System Setup gt C TSI Map Setup Access the TSI Map setup it allows up to set up to four maps setting but only one can active After choose the map number select the desired slot and port number for the mapping target Next select the starting timeslot number and the timeslot amount T S and data or voice mode for the target Also select the desired slot port and starting timeslot number T S for the mapping source After setup select Yes for confirmation Under the Controller Setup menu press C to setup TSI map LOOP AM3440 C System Setup MAP 6 02 10 09 09 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO Target MQ E1 NON CAS Source RTR Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO Slot Port 1 d B 1 17 d B T 1 1 17 d A TS 2 d B 2 18 d B 18 2 d A 2 18d A 3 d B 3 189 d B 189 3d A 3 19d A 4 d B 4 20 d B 20 4 d A 4 20d TS 5 d B 5 21 d B 21 5d A 5 21d A Clear 6 d B 6 22 B 22 6 22 d d v 7 d B 7 23 d B 23 7 d A 7 23 d A 8 d B 8 24 d B 24 8 d A 8 24 d A 9 d B
14. 6 6 6 Unit Alarm History Chapter 6 Terminal Operation To view the unit alarm history press H from Port Menu SLOT A MQuad El PORT 2 LOCAL ALARM TYPE RAI AIS LOS LOF BPV 10E ES E UAS 1 CSS 1 THRESHOLD 5 lt lt ESC key to return to previous menu Port Alarm History CURR STATE COUNT 0 0 0 0 0 0 0 0 ALA MAJO MAJO MAJO MAJO MAJO MAJO MAJO MAJO 10 24 44 10 27 2004 RM A SPACE bar to refresh gt gt 6 6 7 Unit Alarm Queue Under Port Menu press Q to view the alarm queue as the following screen shows SLOT A MQuad El PORT 2 T Az E 4 2 Blot vA E1 3 Sec Slot E144 4 Slot A E1 3 22 SI mt A E1 4 Go E Leto 1 3 7 Slot A E 4 8 Slot X E1 3 Gore Slot A 1 2 10 Slot E 2 11 Slot E 4 12 Slot A E 4 oSlet 1 3 LA c SIYE A E1 3 15 mes Sgt A 1 2 16 ee Slot A E 3 lt lt ESC key return to MAJO MAJO MAJO MAJO MAJO MAJO MAJO MAJO MAJO MAJO MAJO MAJO MAJO MAJO MAJO MAJO AMENS NHUJXWSJ No Unit Alarm Queue UAS UAS UAS UAS UAS UAS UAS UAS RAI RAI previous menu or SPACE bar to refresh 10 25 10 10 27 2004 0 24 51 10 27 2004 0 24 51 10 27 2004 0 24 49 10 27 2004 0 24 49 10 27 2004 0 09 38 0 27 2004 02 09 38 0 27 2004 00 937 0 27 2004 0 09 37
15. Current 24 Hour Interval 07 23 2002 07 22 2002 07 21 2002 07 20 2002 07 19 2002 07 18 2002 07 17 2002 lt lt TAB key to show Statistics Report gt gt lt lt ESC key to return to previous menu SPACE key to refresh 114 Chapter 6 Terminal Operation SLOT D ATM FR El Port 1 Hour Stat Report 16 30 20 07 24 2002 LINE Valid Seconds in Current 15 Min Interval 33 seconds AS SEFS SES SBES SES DM CSS Current 15 Min 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 100 00 Lst NSaTEestoBS Madbo ss sass Sass pS SSS SSR SSSR SES SSS See mete 2nd Nearest LOMEN SSSR Seo ne eme SP ee evergreen Reine 2rd Nearest fo Min desee Ium SSS ees SSSR SSS ese MESSE Sense 4th Nearest 15Min os Sess Ses aS Seana see so SSeS ee ey Se eee ceu es eremum es Valid 15 Min Intervals in Current 24 Hour Interval 0 SAS SEFS SES SBES SSES DM SCSS Current 24 Hour TS SSR om DESSERT ETS Se SSS Pose 07 23 2002 DPSS eS She sei ARS RE SOS RO aS SS ene aS 07 22 2002 Se SS Sate SSeS ae ie ESS res 07 21 2002 FOREST SS RRS SS SSS SSS SSS SSS NSS SSS SSeS SSS 07 20 2002 oy tis oe SE pur we RSS VE PEER CESSE RSS 07 19 2002 DST DS ie aS EE SOS ES eu decem SES CESSER Er CSS EN En ESS SR 07 18 2002 E RE ST USERS MESSE RSS Ore CS ER US RS 07 17 2002 CN EE e EE pui e ouem lt lt TAB key to
16. Device Name LOOP AM3440 C System Location 8F No 8 HSIN ANN ROAD SCIENCE BASED INDUSTRIAL PARK HSINCHU 30077 TAIWAN System Contact Name FAE Tel 886 3 5787696 Fax 886 3 5787695 E mail FAEG8loop com tw SNMP Model VI only lt lt Press ESC key to return to previous menu gt gt 54 Chapter 6 Terminal Operation V1 Trap Setup Press B from the main menu to set up Trap and Community The user can set a maximum of five trap IP for SNMPv1 The trap IP is the server s IP for NMS management Once an alarm occurs in the AM3440 controller the alarm will be sent to the target trap IP address trough LAN or WAN depending on the trap system IP you choose To set up the Trap IP follow the procedures below LOOP AM3440 C Trap and Community 12 09 51 07 15 2010 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Get Community public Set Community public Trap IP 1 Community Name public 1 2 Community Name public Trap IP 3 Community Name public Trap IP 4 Community Name public Trap IP 5 Community Name public 2 Trap system IP 3 Alarm Trap Type lt lt Press ESC key to return to previous menu gt gt 1 Key in the trap IP address and its community name The default setting for community name is public 2 The trap system IP is the trap s source IP address Select LAN or WAN for trap system IP and the selection will determine the direct
17. LOOP AM3440 C Power Setup 152247219 1l 2317 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Power 1 Type 48V DC Power 2 Type 48V DC lt lt Press ESC key to return to previous menu gt gt 6 2 7 19 Multicast Mapping Procedure LOOP AM3440 C Controller Menu 15 54 01 11 27 2008 Slot AD 1559 Serial Number 7123472 Redundant Controller Disabled Hardware Version Ver G Start Time 09 42 21 11 27 2008 Software Version V7 05 01 10 28 2008 Device Name LOOP AM3440 C DISPLAY SETUP C System Configuration S gt System Setup gt Clock source Configuration gt System Alarm Setup Q gt Alarm Queue Summary W gt Firmware Transfer gt Information Summary V gt Store Retrieve Configuration R gt Redundant Board Information K gt Clock source Setup P gt Performance Report T gt Bit Error Rate Test LOG MISC U gt Choose a Slot A gt Alarm Cut Off F gt Log Off SETUP MISC Menu X gt Clear Alarm Queue O gt Log On SETUP MISC Menu Y gt Controller Return to Default Z Controller Reset gt gt SPACE bar to refresh or enter a command gt 68 Chapter 6 Terminal Operation Press S from the Controller Menu screen to enter into the Controller Setup menu see also below screen LOOP AM3440 C Controller Setup 15 54 53 11 27 2008 System SNMP Setup Password TSI Map Setup Select a New TSI Map Copy a TSI Map to Another C
18. Ne jamais installer la prise t l phonique dans un endroit humide sans prendre la pr caution que cette prise t l phonique soit pr vu pour un environnement humide Ne jamais toucher les fils t l phoniques d nud s sans que la prise t l phonique soit d branch du r seau Prendre toutes les pr cautions d usages pendant l installation ou les modifications de la ligne t l phonique This Manual is in several volums Main Chassis LOOP AM3440 C Wideband Access DCS MUX USER S MANUAL LCD Manual only cover selected plug in module 1DTE Manual 1FOM Manual 1FOMA Manual 3E1 Manual 4E amp M Manual 4FXSFXO Manual 8bE amp M Manual 8RS232 Manual Conference Manual Data Bridge Manual Dry Contact Dry Contact B Manual G SHDSL Manual Low Speed Optical C37 94 Manual Magneto Manual Router Manual Router A Manual Router B Manual Single E1 T1 Manual Card Terminal Server Manual 12 24 FXSFXO Manual U interface Manual Discontinued Please refer to the Manual the meets your specific needs 1 Table of Contents PRODUCT DESCRIPTION ssinsanasennadies EE 1 1 1 FUNCTION DESCRIPTION ste a babe astres Rebate a E ares 1 1 2 PHYSICAE DESCRIPEION AL RAM ettet edt ue eerte eer e e det ie eter en Re 1 1 3 APPLICATION ee AURA Tee ara ert 2 1 4 SPECIFICATIONS FOR
19. UNSYNC 4 8RS232 8X50 Card Vendor Spec Assigned Alarm type 20 dte ext clk loss 51 1 EXT CLK LOSS 21 dte rts loss 512 RTS LOSS 22 dte remote alarm 513 REMOTE ALARM 5 DTU 6 10 Card Vendor Spec Assigned Alarm type 20 dtu unsync 503 UNSYNC 6 MDSL Card Vendor Spec Assigned Alarm type 20 mdsl master los 361 LOS MASTER LOOP 21 mdsl slave los 362 LOS SLAVE LOOP 22 mdsl master es 15m 363 ES15M MASTER LOOP 23 mdsl slave es 15m 364 ES15M SLAVE LOOP 24 mdsl master ses 15m 365 SES15M MASTER LOOP 25 mdsl slave ses 15m 366 SES15M SLAVE LOOP 26 mdsl master es 24h 367 ES24H MASTER LOOP 27 mdsl slave es 24h 368 ES24H SLAVE LOOP 28 mdsl master ses 24h 369 SES24H MASTER LOOP 29 mdsl slave ses 24h 370 SES24H SLAVE LOOP 164 Chapter 10 Appendix D LOOP AM3440 C ALARM TRAP INFORMATION 30 mdsl mclk loss 371 MCLK LOSS 31 mdsl sealing current 372 SEALING CURRENT 7 ATM E1 T1 Card Vendor Spec Assigned Alarm type 21 e1 rai 201 RAI or YEL t1 yel 221 22 e1 ais 202 AIS t1 ais 222 23 e1 los 203 LOS t1 los 223 24 e1 lof 204 LOF t1 lof 224 25 e1 bpv 205 BPV t1 bpv 225 26 e1 es 206 ES t1 es 226 27 e1 uas 207 UAS t1 uas 227 28 e1 css 208 CSS t1 css 228 29 atm los 261 ATM LOS 30 atm ais 262 ATM AIS 31 atm rdi 263 ATM RDI 32 atm loc 264 ATM LOC 33 fr Ikd 265 FRLKD 8 QE1 Mini QE1 3E1 Card Vendor Spec Assigned Alarm type 20 e1 rai 201 RAI 21 e1 ais 202 AIS 22 e1 los 203 LOS 23 e1 lof 204 LOF 24 e1 bpv
20. for EN option Then key in the IP address and subnet mask of the unit you wish to communicate with You can also choose HDLC or PPP for the frame Press ESC to save your new setting Once you complete the procedures above the AM3440 units will start activating WAN network communication Note To manage your AM3400 units through LAN enable the LAN network and key in the IP address of the unit you would like to manage It is a simple way to manage a specific AM3440 unit LOOP AM3440 C System Setup SYSTEM 15 47 02 09 09 2011 Please nput decimal number 0 9 BACKSPACE to edit System Time Date 15 47 02 09 09 2011 Device Name LOOP AM3440 C Network NI EN IPAddress SubnetMask Frame LB Timer LAN ON 192 168 014 189 255 255 255 000 Ethernet WAN OFF 010 010 012 002 255 255 255 000 HDLC 00000001 Gateway Interface LAN Gateway IPAddr 192 168 014 254 CONSOLE port Baud Rate 9600 Data Length S Bi ts Stop Bit 2 LSBLe Parity NONE XON XOFF XOFF TSI map Clock TSI Function l 1 Bidirection Clock Mode Normal Idle Signalling 1010 lt lt Press ESC key to return to previous menu gt gt Note NI Network Interface EN Enable DIS Disable LB Timer Loopback Timer The system application for WAN and LAN communication is as below AM3440 AM3440 Note Inband 1 Use VT100 terminal to enable LAN network Ethernet Port This way you can manage a spec
21. ES UAS BES SES CSS LOFC Current 24 Hour Interval RES TL Se RSS VERRE EME SSSS lt lt TAB key to show Statistics Report gt gt lt lt ESC key to return to previous menu SPACE key to refresh gt gt 111 Chapter 6 Terminal Operation SLOT D ATM FR T1 Port 1 Hour Stat Report 172483 05 07 21 2002 USER Valid Seconds in Current 15 Min Interval 290 seconds AS SEFS SES SBES SSES CSS SLOFC Current 15 Min 100 00 100 005 0 0000 0 0000 0 0000 0 0000 0 00005 Nearest 53 decem Sate e e mee E Sin Euer eee 2nd Nearest 15 Min HSE eu AnD ari RER Sones ores eee nese 3rd Nearest PoSMAn HSE CESSE Se RA e SSeS 4th Nearest 15 Min S E jue E a a E E le RSS e pnm E Valid 15 Min Intervals in Current 24 Hour Interval 0 SAS SEFS SES SBES SES CSS Current 24 Hour rae ue Sere ee ts unice ure cse cepe IN DID lt lt TAB key to show Performance Report gt gt lt lt ESC key to return to previous menu SPACE key to refresh gt gt SLOT D ATM FR T1 Port 1 Hour Perf Report JTSISLZO 07721 2002 LINE Valid Seconds in Current 15 Min Interval 321 seconds ES UAS BES SES CSS LOFC Current 15 Min Interval 5 0 0 0 0 0 0 Ist Nearest l5 Mim Interval i esse ened ieget Sesto Rte 2nd Nearest LoSMin Interval ee Hess
22. LOOP AM3440 C SNTP setup ARROW KEYS CURSOR MOVE TAB ROLL UP DOWN OPTIONS 15 22 58 11 27 2008 SNTP ON OFF OFF SNTP server 1 000 000 000 000 SNTP server 2 000 000 000 000 SNTP timezone 0 lt lt Press ESC key to return to previous menu gt gt 6 2 7 17 LNET SSH Setup Controller Menu gt S System Setup gt H TELNET SSH Setup SSH Secure Shell is a network protocol that allows data to be exchanged over a secure channel between two computers Encryption provides confidentiality and integrity of data SSH uses public key cryptography to authenticate the remote computer and allow the remote computer to authenticate the user if necessary TELNET TELecommunication NETwork is a network protocol used on the Internet or local area network LAN connections LOOP AM3440 C TELNET SSH Setup 15 25 59 11 27 2008 ARROW KEYS CURSOR MOVE ENTER KEY ITEM SELECT SSH Server OFF TELNET Server ON lt lt Press ESC key to return to previous menu gt gt Note Configuration Option Default SSH Server ON OFF TELNET Server ON OFF OFF 67 Chapter 6 Terminal Operation 6 2 7 18 Power Setup Controller Menu gt S System Setup gt P Power Setup The default value is 48 V DC Of the four kinds of power type 48V DC 24V DC 125 V DC and AC The system of AM3440 will not note the power type so the user needs to choose it manually
23. M LOCAL DTE M1 existed RTS LOSS EXT CLK LOSS DSR YES CTS YES DCD YES DTR NO RTS YES Loopback Status DTE Loopback 6 4 3 Alarm History To view the alarm history press H from the Port Menu The screen will show as below OFF OFF Unit Status 09 46 44 05 23 2001 SPACE bar to refresh gt gt lt lt ESC key to return to previous menu 2 2 3 4 5 Port SLOT 3 X50 PORT 1 State OK OK OK Count 0 0 0 Alarm History Alarm DISABLE DISABLE DISABLE ESC to return to previous menu SPACE to refresh 09 46 47 05 23 2001 U key to change unit gt gt 107 Chapter 6 Terminal Operation 6 4 4 System Setup To setup the system press S from the Port Menu The screen will show as below SLOT 3 X50 PORT 1 Setup Configeration 15 07 06 05 08 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS SRE LOCAL X50 MUX NO MUX SYNC mode SYNC Rate gt OSIZK Phase fixed 4 8k sel fixed Clock Normal Data Normal RTS Permanent TTM Off DCD Permanent ON Interface RS 232 lt lt Press ESC key to return to previous menu or save setup gt gt Note Configuration Option Default X50 MUX No MUX 1 2K to 64K data rate MUX 1 2K to 9 6K data rate No MUX SYNC mode SYNC ASYNC 8 ASYNC 9 ASYNC 10 ASYNC 11 SYNC Rate Please refer to the data rate table below for detail information 4 8k
24. Upload Configuration Download Mainboard Boot up Copy Firmware to Redundant DAHvUAW LY lt lt Press ESC key to return to Main Menu or enter a command gt gt 84 Chapter 6 Terminal Operation B 7 Enter the proper TFTP Server IP address and the firmware file name LOOP AM3440 C Download Firmware ARROW KEYS CURSOR MOVE Please Input 11 54 03 12 05 2008 nnn nnn nnn nnn BACKSPACE to edit Firmware 1 Version V7 04 03 09 10 2008 Firmware 2 Version s WVTSOS 01 10 28 2008 Current Firmware Bank 2 Next Boot Firmware 252 TFTP Server IP 000 000 000 000 Firmware File Name lt lt Press ESC key to return to previous menu gt gt NOTE When new firmware is downloaded to a AM3440 C that has its current firmware in BANK 1 the new firmware is not activated until the AM3440 is rebooted Upon reboot the newly downloaded firmware will automatically be switched to BANK 2 and it will become the new current firmware Similarly if the current firmware is in BANK 2 the newly downloaded firmware will be switched to BANK 1 upon rebooting BANKS only switch after a download occurs and the AM3440 is rebooted B 8 Press ENTER then Really want to download Y N shows on the screen press Y to confirm the download or N to abort it B 9 As the download is completed press ESC to return to the File Transfer screen B 10 Press ESC to return to the Controller Menu screen B 11
25. c run 17 27 03 07 21 2002 lt lt Press ESC key to return to previous menu gt gt 137 Chapter 6 Terminal Operation 6 5 15 Unit Load Default Configuration Under the port menu press Y to download firmware Then press Y or N to confirm the selection SLOT D ATM FR El Download Firmware 17 27 03 07 21 2002 Return to default are you sure Y N Note When you load the default configuration the current daughter card map will not be cleared 6 5 16 Unit Reset Press Z from Port Menu to reset the unit Then press Y or N to confirm the selection SLOT D ATM FR El Download Firmware 17 27 03 07 21 2002 Reset are you sure Y N 6 6 Mini Quad E1 Sub Menu Under the Controller Menu press U to choose a slot for Quad E1 port The screen will show as below Then press P to choose mini Quad E1 port press ENTER to get into the port menu SLOT A MQuad E1 PORT 2 Port Menu 10 28 12 10 27 2004 Version SW 51 0 10 20 2004 DISPLAY SETUP gt Unit 1 Hour Perf Report L Unit Loopback Setup 2 Unit 24 Hour Perf Report S Unit System Setup A Unit Line Availability K gt Unit Clear Performance Data C Unit Configuration M Unit Alarm Setup gt Unit Status X gt Unit Clear Alarm Queue amp History H Unit Alarm History D Unit Upgrade Firmware Q Unit Alarm Queue LOG MISC U Choose Other
26. eem 3rd N arest Lo Min Tnterval On Sates BUTS prenne oases 4th Nearest 15 Mim Interval lt Ses Seem cen Lm Valid 15 Min Intervals in Current 24 Hour Interval O0 ES UAS BES SES CSS LOFC Current 24 Hour Interval homes Sene deg Passer ere Ses ere se lt lt TAB key to show Statistics Report gt gt lt lt ESC key to return to previous menu SPACE key to refresh gt gt 112 Chapter 6 Terminal Operation SLOT D ATM FR T1 Port 1 Hour Stat Report 17328422 OF 721 7 2002 LINE Valid Seconds in Current 15 Min Interval 321 seconds SAS SEFS SES SBES SSES CSS LOFC Current 15 Min 100 00 100 00 0 0000 0 0000 0 0000 0 0000 0 0000 TSt Nearest 5M dece ves pS SSSR quee eee SES 2nd Nearest 15 Min SSSR ey Eee Em See ey SSS a aie NES EIE aee IEEE 370 Nearest PoSMAn HSE CESSE SaaS SSS SSS a 4th Nearest 15 Min oe Sia aS age a Se aS See Se Se aa Valid 15 Min Intervals in Current 24 Hour Interval 0 SAS SEFS SES SBES SES CSS LOFC Current 24 Hour Doni eie Tepic SSSR lees Se SSS SSSR lt lt TAB key to show Performance Report gt gt lt lt ESC key to return to previous menu SPACE key to refresh gt gt 6 5 1 2 ATM Frame Relay E1 To view ATM FR E1 port 1 hour performance report by selecting register type
27. terree etr ne ere te ERE E e 164 10 72 ALARM SETUP INDICATION iei ipe diee eres 169 11 APPENDIX E SETTING UP AN 3440 PDH SHARED PROTECTION 170 OVERVIEW entente ra ee ra eem rd tete eem ep deer ees 170 SETUP INSTRUC TONG EE eec eden RID RORIS 171 12 12 1 12 2 13 APPENDIX SETTING UP AN AM3440 C PDH SHARED PROTECTION RING T1 OVERVIEW 1 ee ek ot E cada ee Ee P MAN SETUPTINSTRUGTIONS os Le Meur id e er Oe I Ne et e IR LG Se APPENDIX AM3440 C POWER enses esta en nons sone tatu List of Figures Figure 1 1 AM3440 C Application Illustration 1 52 2 Figure 1 2 AM3440 C with Y BOX 2 of 2 eene nennen EIEEE nennen 2 Figure 2 1 Ground Screw Location 14 Figure 2 2 DC Power Without With Grounding 14 Figure 2 3 Panel Views Main Shelf and 15 Figure 2 4 Jumper Location for Mini Quad E1 18 Figure 3 1 HDLC using Loop V 4200 34 Figure 6 1 AM3440 Controller Menu Tree sienne 41 Figure 8 1 Inband Management Diagramme 151 Figure 9 1 Connection for AM3440 C and Y BOX with BNC connectors 155 Figure 9 2 Connection for AM3440
28. 2 ports per card 300 600 1 2K 2 4K 4 8K 9 6K 19 2K not supported Two DB9 DCE female Two RJ11 G 723 gt 46dB Max 70dBmO transmit D A gain 0 6dB receive A D gain 6 0 6dB gt 25dB with 1004 Hz OdBm input Max 65 dBmOp Max 1800 ohm Normal 48 Vdc with 25mA current limit 2 REN 20Hz 76 Vrms 2 sec 4 sec off for 1 min or 1 sec on 2 sec off for 30 sec programmable Loop Start DTMF Two RJ45 G 723 Balanced 600 ohms gt 46dB transmit D A gain 0 6dB receive A D gain 6 0 6dB gt 25dB with 1004 Hz OdBm input Max 65 Side A exchange side Side B carrier side Jumper selectable Type P Jumper enable Master standard Jumper selectable 4 wire Type 1 Type 4 and Type 5 Jumper selectable Single rainging for 5 sec only 2 sec on 4 sec off for 1 min or 1 sec on 2 sec off for 30 sec programmable Voice Card QFXS QFXO Connector Alarm Conditioning Encoding AC impedance Longitudinal Conversion Loss Loss Adjustment Signal Distorition Frequency Response FXS Loop Feed FXS Ringing FXO Ringing REN Metering Pulse Signaling Inband Singaling Tone Chapter 1 Product Description Four RJ11 CGA busy after 2 5 seconds of LOS LOF A law or u law user selectable per card Balanced 600 or 900 ohms user selectable per card gt 46dB 0 3 6 or 9 dB transmit amp receive user selectable per card gt 25dB with 1004 H
29. 51 0 10 20 2004 Good Working Firmware Bank 1 TFTP Server IP 000 000 000 000 Firmware File Name lt lt Press ESC key to return to previous menu gt gt 146 Chapter 6 Terminal Operation 6 6 14 Unit Load Default Configuration Press Y to return to default then confirm it by pressing Y or N SLOT A MQuad El PORT 2 Port Menu 10 28 12 10 27 2004 Version SW S1 CO 10 20 2004 DISPLAY SETUP gt Unit 1 Hour Perf Report L Unit Loopback Setup 2 Unit 24 Hour Perf Report S gt Unit System Setup A Unit Line Availability K gt Unit Clear Performance Data C gt Unit Configuration M Unit Alarm Setup gt Unit Status X Unit Clear Alarm Queue amp History H Unit Alarm History D Unit Upgrade Firmware Q Unit Alarm Queue LOG MISC U gt Choose Other Slot Y gt Unit Load Default Config P Choose Port 2 Unit Reset F Log Off SETUP MISC Menu O gt Log On SETUP MISC Menu E Return to Controller Main Menu Return to default are you sure Y N Note When you load the default configuration the current daughter card map will not be cleared 6 6 15 Unit Reset Under Port Menu press 2 to reset unit Press Y or to confirm it SLOT A MQuad El PORT 2 Port Menu 105208522 IO0Z2T 2004 Version SW S1 CO 10 20 2004 DISPLAY SETUP Unit 1 Hour Perf Report L Unit Loopback Set
30. BACKSPACE to edit LECH JLDLCrI vcr BR IWK amp Translation DE CLP index 4 04 HDLC 103 00103 0064 MAP 12 5 0 0 0 0 0 lt 0 gt Network MAP 126 0 0 0 0 0 lt 0 gt Network MAP 127 0 0 0 0 0 0 Network MAP 128 0 0 0 0 0 0 Network MAP 1 1 16 100 100 64 lt 64 gt Network MAP 2 2 0 101 101 256 lt 0 Network 0 3 3 18 102 102 64 64 Network MAP 4 0 0 0 0 0 0 Network MAP 5 0 0 0 0 0 0 Network MAP 6 0 0 0 0 0 0 Network MAP 7 0 0 0 0 0 0 Network MAP 8 0 0 0 0 0 0 Network MAP 9 0 0 0 0 0 0 Network MAP lt lt Press ESC key to return to previous menu gt gt 131 Chapter 6 Terminal Operation 3rd screen SLOT D ATM FR El Port Connection Table Setup 10 25 48 09 13 2002 Please Input 1 10 BACKSPACE to edit CH DLCI VPI VCI BR IWK amp Translation DE CLP index 4 00 HDLC 103 00103 0064 MAP 1255 0 0 0 0 0 lt 0 gt Network MAP 126 0 0 0 0 0 lt 0 gt Network MAP 127 0 0 0 0 0 lt 0 gt Network MAP 128 0 0 0 0 0 0 Network MAP d 1 16 100 100 64 lt 64 gt Network MAP 2 2 0 101 101 256 lt 0 Network 0 3 3 18 102 102 64 64 Network MAP 4 0 0 0 0 0 0 Network MAP 5 0 0 0 0 0 lt 0 gt Network MAP 6 0 0 0 0 0 0 Network MAP 7 0 0 0 0 0 0 Network MAP 8 0 0 0 0 0 lt 0 gt Network MAP 9 0 0 0 0 0 0 Network MAP lt lt Press ESC key to return to previous menu gt gt 6 5 11 2 4 Connection Table Setup
31. Choose Other Slot Z Unit Reset Choose DTE Port Return to Main Menu gt gt SPACE bar to refresh or enter a command gt 94 Chapter 6 Terminal Operation 6 2 17 DTE Configuration By pressing C the unit setup menu is displayed as follows For V 35 DTE Interface SLOT 3 DTE PORT 1 Unit Configuration 18 35 23 03 01 2001 Ed LOCA Le Channel vc Rate 64KBps Clock Normal Data Normal RTS Active TTM s Of V 54 s OLE INTERFACE V 35 lt lt ESC key to return to previous menu SPACE bar to refresh gt gt For V 36 DTE Interface SLOT 3 DTE PORT 1 Unit Configuration 15 39 39 04 29 2004 LOCAL Channel ME Rate 64KBps Clock Normal Data Normal RTS Active TTM V 54 OEE INTERFACE V 36 lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 95 Chapter 6 Terminal Operation For EIA530 RS449 DTE Interface SLOT 3 DTE PORT 1 Unit Configuration 15 41 54 04 29 2004 LOCAL Channel 2 0 Rate 64KBps Clock Normal Data Normal RTS Active TTM sr OEE V 54 INTERFACE EIA530 RS449 lt lt ESC key to return to previous menu SPACE bar to refresh gt gt For X 21 V 11 DTE Interface SLOT 3 DTE PORT 1 Unit Configuration 15 40 36 04 29 2004 LOCAL Channel 2 0 Rate
32. FR to ATM Select the CONN TAB item on the Port System Setup menu Use this management setup to link the connection table to that of the ATM network The channel number can be 1 to 31 All the numerical entries must be coordinated with the ATM network The meanings of the table columns are as follows Column Heading CH Options 1 31 16 991 Meaning Logical channel number Data Link Connection Identifier within the channel 1 255 Virtual Path Identifier from ATM BR 1 65535 1 1920 Virtual Channel Identifier from ATM Bit Rate requested in Kilobits sec for this VC Blank 1 1920 Actual Bit Rate allocated Kilobits sec IWK amp Translation Network SVC Mode1 SVC Mode 2 SVC YES SVC NO Network inter working FRF 5 Service inter working FRF 8 Map FECN field in Frame Relay to ATM EFCI field Service inter working FRF 8 ATM EFCI is always set to congestion net experienced Translation column appears in table see Translation below Translation column appears in table see Translation below SVC YES SVC NO Do translation between Frame Relay FRF 3 and ATM RFC1483 Forward encapsulations unaltered MAP Maps content of DE discard eligibility in Frame Relay or CLP cell loss probability in ATM to CLP in ATM DE in Frame Relay Regardless of contend of DE and CLP set outgoing DE and CLP to constant 0 Regardless of contend of DE and CLP set outgoing DE
33. Figure 9 3 Line Protection for Quad E1 Card 157 Chapter 9 Appendix C QDS1 1 1 Protection 9 3 1 Step by Step Quad E1 Card Line Protection Setup The sample screens below provide step by step instructions for setting up Quad E1 Line Protection In our sample setup we installed Quad E1 cards in slot 3 and slot 4 The card in slot 3 will be working slot and slot 4 will be stand by Go to Controller Menu gt S System Setup gt Q QDS1 1 1 Protection select Setup and press Enter The Setup menu is to setup the protection modes for each protection pair and ports LOOP AM3440 C QDS1 1 1 Protection 17 42 06 08 02 2011 gt gt Select Setup Status On the Setup Screen there are six selection for the user to setup such as disable circuit line non revertive line revertive 1 1 non revertive and 1 1 revertive The sample below is to setup the port 2 of slot 3 4 as LINE NONREV protection and to setup the port 3 of slot 4 as 1 1 NONREV protection It means Slot 3 port 2 is protection working port and slot 4 port 2 as backup in LINE Non Revertive mode and Slot 3 port 3 is protection working port and slot 4 port 3 as backup in 1 1 Non Revertive mode LOOP AM3440 C QDS1 1 1 Protection 16 57 54 08 02 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Protect Pair Master Backup Port 1 Port 2 Port 3 Port 4 Slot A B FE1 FE1 Slot C D FOM
34. MISC Menu X gt Clear Alarm Queue O gt Log On SETUP MISC Menu Y gt Controller Return to Default 2 Controller Reset gt gt SPACE bar to refresh or enter a command gt 6 2 1 System Configuration Press from the Controller Menu the screen of System Configuration will show as below LOOP AM3440 C Controller Configuration 15 15 45 09 09 2011 A System B Clock Source C TSI map D Current TSI map Power Fan Status Q gt Link Backup Function Q gt QDS1 1 1 Protection DSO SNCP Status R PDH Ring Protection Status lt lt Press ESC key to return to Main Menu or enter a command gt gt 42 Chapter 6 Terminal Operation 6 2 1 1 System Press A from the Controller Configuration Menu the screen of System Configuration will show as below SSM Synchronous Status Message LOOP AM3440 C System Configuration 15 16 24 09 09 2011 System Device Name LOOP AM3440 C Network NI EN IPAddress SubnetMask Frame LB Timer LAN ON 192 168 014 189 255 255 255 000 Ethernet WAN SOFE 10 010 012 002 255 255 255 000 HDLC 1 Gateway Interface LAN Gateway IPAddr 192 168 014 254 CONSOLE port Baud Rate 9600 Data Length 8 Ba ts Stop Bit Bart Parity NONE XON XOFF XOFF TSI map Clock TSI Function 1 1 Clock Mode SSM dle Signalling 1010 lt lt ESC key to return to
35. SES LOCAL E1 Chapter 10 Appendix D LOOP AM3440 C ALARM TRAP INFORMATION 40 fom e1 local uas 621 UAS LOCAL E1 41 fom e1 local bpv 622 BPV LOCAL E1 13 C37 94 Card Vendor Spec Assigned Alarm type 20 Iso los 441 LOS 21 Iso yel 442 YEL 22 Iso es 443 ES 23 Iso ses 444 SES 24 Iso uas 445 UAS 14 Dry Contact Dry Contact B Vendor Spec Assigned Alarm type 20 dc n1 p1 701 Input port 1 pair 1 21 dc n1 p2 702 Input port 1 pair 2 22 dc n1 p3 703 Input port 1 pair 3 23 dc n1 p4 704 Input port 1 pair 4 24 dc n2 p1 705 Input port 2 pair 1 25 dc n2 p2 706 Input port 2 pair 2 26 dc n2 p3 707 Input port 2 pair 3 27 dc n2 p4 708 Input port 2 pair 4 167 Chapter 10 Appendix D LOOP AM3440 C ALARM TRAP INFORMATION 15 OCU DP Card Vendor Spec 16 RT Card Vendor Spec 20 21 17 RT A Card Vendor Spec 20 21 18 RT B Card Vendor Spec 19 TDMoE Card Vendor Spec Assigned ocudp los 461 ocudp oos 462 ocudp es 465 ocudp ses 466 ocudp uas 467 ocudp loopbk 468 ocudp test 469 ocudp lof 470 Assigned lan1 link down 401 lan2 link down 402 Assigned lan1 link down 401 lan2 link down 402 Assigned lan1 link down 401 lan2 link down 402 lan3 link down 403 lan4 link down 404 lan5 link down 405 lan6 link down 406 lan7 link down 407 lan8 link down 408 Assigned tdmoe arp lost 1001 tdmoe rx lost 1002 tdmoe cell lost 1003 tdmoe jit buf underrun 1004 tdmoe jit buf o
36. Table 2 13 Default Software Configuration LT Sonsols Port Fed 23 Chapter 2 Installation DTE V 35 V 36 EIA530 X 21 V 11 Item RATE 64K V 35 INTERFACE V 36 Depend on which DTE card is plugged EIA530 RS449 into the shelf X 21 V 11 ATWFRTiLieWems Dean Alarm Indication Signal ENS LONG HAUL ATM FRE Lineltems Frame Format Mode on E ReweSeup 24 Chapter 2 Installation E amp M Card Default Configuration Option Range Default Side A Side B Side Depending on side switch setting 600 ohm 900 ohm 600 ohm Signaling Type Type 2 Type 3 Type 4 and Type 5 or Tx only Tx Gain 10 to 7 dB Rx Gain Miscellaneous Dem LOOP LOOP 3440 25 Chapter 3 Operation 3 Operation 3 1 Quick Start for Loop AM After installation the user may want to familiarize himself with the equipment immediately The following abbreviated instructions will give the user a quick start 3 1 1 Power On Turn power on by attaching a power cable to the front of the unit 3 1 2 Load Default The unit is shipped with factory default setting Upon initial power up you will see the following screen on your VT 100 monitor The AM3440 C will automatically load the system hardware configuration stored in the flash memory If you prefer to load the factory default configuration press the ACO button during the countdown
37. gt Controller Reset 50 Chapter 6 Terminal Operation 6 2 6 Performance Report Press P from the Controller Menu then press A to access DSO SNCP performance report LOOP AM3440 C Performance Report 18 03 58 10 08 2009 A gt DSO SNCP Performance DSO SNCP report is the 7 days performace data of the setted DSO SNCP protection group The sample screen below shows the system now has five working DSO SNCP groups You can see the timeslot elapsed seconds of the protected slot and port LOOP AM3440 C DSO SNCP Performance Report 18 04 15 10 08 2009 Idx Protected AS S P TS Elapsed Today 10 07 10 06 10 05 10 04 10 03 10 02 10 01 1 A 0 01 165 82 2 0 02 165 82 3 0 03 165 82 4 A 0 04 165 82 5 A 0 05 165 82 Before you get access to DS0 SNCP Performace Report make sure you have already set up at least one DSO SNCP group with 3E1 plug in cards To set up DSO SNCP protection choose the DSO SNCP setup function on the VT100 menu command path Main Menu S System Setup K DSO SNCP Setup set DSO SNCP to ENABLE and set Action to Create Then press ENTER LOOP AM3440 C DSO SNCP Setup 09 49 51 10 09 2009 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS DSO SNCP ENABLE Using Map MAP 1 Action Create lt lt Press ESC key to return to previous menu gt gt Select two 3E1 cards for DSO SNCP protection and a
38. gt gt 120 Chapter 6 Terminal Operation 6 5 5 2 Alarm History FR to FR SLOT D ATM FR El LOCAL YEL LKD ALARM TYPE THRESHOLD 10E 5 Port Alarm History a R STATE COUNT ALAR 0 EN EN EN EN EN EN EN EN EN LM gt gt gt gt gt gt w w w w tU w w tU w NORCOFRFO LM lt lt ESC key to return to previous bar to refresh gt gt 6 5 6 Port Status Press E Ed Dd Dd bd Dd d Dd Dd o 17 24 14 07 21 2002 from the port menu the following screen will show To view the port status for the ATM FR T1 interface by selecting ATM status type The current selection will be highlighted by an asterisk NOTE When Frame Relay is selected ATM Status will be hidden SLOT D gt gt Select ATM Status Type ATM FR T1 Port Status 2 T1 E1 Status FR Status 17 24 32 07 21 2002 ATM Status 6 5 6 1 T1 E1 Status SLOT D LINE LOS LOF RCV A RCV Y XMT A XMT Y BPV E ES E TEST PATTE NEAR IS EL IS EL NO NO NO NO NO NO ATM FR RROR COUNT 0 RROR COUNT 0 RN TRANSMITTED END LOOPBACK Port Status OFF OFF lt lt ESC key to return to previous menu SPACE key to refresh 22 17 24 37 07 21 2002 121 Chapter 6 Terminal Operation 6 5 6 2 Frame Relay Status 6 5 6 2 1 FR to
39. lt ENTER edit Storage NonVolatile View Family 1 3 View Name one Sub tree LS 6 1556 29 Mask reserved Type include Status Active Storage NonVolatile UP DOWN gt Access View A gt add D gt delete gt gt LOOP AM3440 C SNMP Setup VACM 18 13 26 11 25 2008 Access 2 2 Group Name initial Security Model V3 USM Security Level NoAuthNoPriv LEFT RIGHT gt prev next gt gt 58 Chapter 6 Terminal Operation V3 Target amp Notify Setup Controller Menu gt S System Setup gt S SNMP Setup gt F V3 Target amp Notify Setup F command is to notify the V3 target similar to situation with V1 trap Target 1 1 Target Name mytarget Domain UDP P Address 192 168 1 254 Notify Port 162 Tag groupl Timeout 55 93 Retry 0 Parameter AuthNoPriv one Status Active Parameter 1 1 Param Name AuthNoPriv one MP Model 5 Sec Model PRE Sec Level AuthNoPriv Sec Name loopmd5 Status Active Notify 1 1 Name groupl Tag groupl Type gt Trap Status Active lt lt ENTER gt edit A gt add D gt delete gt gt LOOP AM3440 C SNMP Setup Target amp Notify 18 14 30 11 25 2008 lt lt ESC return to menu UP DOWN gt Target Parameter Notify LEFT RIGHT gt prev next 6 2 7 3 Password Controller Menu S System Setup B Password Under the Controller Setup menu press B to enable or change password
40. then Press D to active gt gt 153 Chapter 9 Appendix C QDS1 1 1 Protection 9 Appendix C QDS 1 1 1 Protection 9 1 Introduction The QDS1 1 1 protection function only apply to Quad E1 T1 Mini Quad E1 and TDMoE Quad E1 T1 cards Apply to QDS1 1 1 protection function two plug in cards must be inserted next to each other as a pair so that one plug in card can be used to protect the other NOTE 1 A pair of Quad E1 T1 Mini Quad E1 and TDMoE Quad E1 T1 cards should be installed in one of the following slot groupings 1 amp 2 3 amp 4 The pair of cards should not be installed in the following groupings 2 amp 3 4 amp 5 Before removing any card from AM3440 shelf please make sure its connecting cables are removed from Quad E1 plug in card first This chapter introduces only 1 1 protection function for a pair of Quad E1 T1and Mini Quad E1 For 1 1 protection function of TEMoE and Quad E1 T1 please refer to the Appendix B of the TDMoE card User s Manual There are two types of protection available for the Quad E1 card and Mini Quad E1 They are Circuit Protection and Line Protection Circuit Protection requires the use of a Loop VV Y BOX This Y Box is specifically designed to provide a 1 1 circuit protection function for the Quad 1 card of the Loop AM 3440 shelf Line Protection does not require the use of a Y Box Each Quad E1 card has four ports The ports of one card protect the corresponding ports of th
41. 0 27 2004 0 moo 35 0 27 2004 00 92 35 0 27 2004 420906231 0 27 2004 0 0 9 2 31 0 27 2004 Quo o9 TL 0 27 2004 022095221 0 27 2004 0209231 0 27 2004 0 09 31 0 27 2004 gt gt 143 Chapter 6 Terminal Operation 6 6 8 Unit Loopback Setup Under Port Menu press L to do Loopback Test then the screen will show as below Use arrow keys to move the cursor press ENTER key to select items SLOT A MQuad E PORT 2 Port Loopback Test ARROW KEYS CURSOR MOVE ENTER KEY ITEM SELECT 10 25 24 10 27 2004 NEAR END LOOPBAC ROE LOCAL PLB LLB SEND LOOPBAC ACTIVATE CODE TO FAR END PAYLOAD LINE SEND LOOPBAC DEACTIVATE CODE TO FAR END PAYLOAD LINE SEND TEST PATTERN OFF PRBS FULL STATUS lt lt Press ESC key to return to previous menu gt gt 6 6 9 Unit System Setup To setup unit system press S from Port Menu then the following screen will show up Use arrow keys to move the cursor TAB key to roll up options NOTE If Protected is set as DISABLE then Master option will show 4 asterisks which means this option is not allowed to set up SLOT MQuad El PORT 2 Port System Setup 10 26 20 10 27 2004 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS FRAME ON CODE HDB3 CRC ON RAI ON AIS FRAMED CAS OFF SIGNALLING TRANS CGA NORM 005 BUSY FDL OFF Sa bit Sa4 IDLE D5 Protected DISABLE Master E RAER I
42. 1 1 protection screen please refer to Appendix C 6 2 7 13 DSO SNCP Setup Follow the command path Main Menu S System Setup K DSO SNCP Setup to access DSO SNCP setup Set DSO SNCP to ENABLE and set Action to Create Then press ENTER LOOP AM3440 C DSO SNCP Setup 09 49 51 10 09 2009 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS DSO SNCP ENABLE Using Map MAP 1 Action Create lt lt Press ESC key to return to previous menu gt gt Select two 3E1 cards for DSO SNCP protection and a particular plug in card as the protected unit and confirm with the setting LOOP AM3440 C DSO SNCP Creation 09 49 12 10 09 2009 Please Input decimal number 1 31 BACKSPACE to edit Protection Group Creation Using map 1 Total DSO SNCP 5 Protected Slot A El US ste me use Ts E Port NON CAS Ta 8 np Count 05 Primary oot 3E EB RA i rt A Sod Mt ee eed Port P NON CAS Protection Delay 00 TS Upstream Send AIS On Secondary Slot 2 35 25 eu er ed ce ERR eri e RU TUE Port P NON CAS Protection Delay 00 l9 0 Upstream Send AIS On Switch Mode Non revertible Confirm Yes lt lt Press ESC key to return to previous menu gt gt Note PDH Ring Protection and PDH Ring Diagnositc are optional functions To access theses two optional functions you must order the controller card with PDH function or these
43. 100 6 2 25 R et rnito Default es OE e atte bun Ee SETS 100 6 2 26 Reset Current DTE Board us t n ER b mue itecto 100 6 3 DTE X21 SUB MENU 5 nan ner er nre rs 100 6 3 1 DELE Configuration eo e e e re be e ope e 101 6 3 2 DLE SUUS s a Susy 101 6 3 3 ates abre i ve A I eA diu 102 6 3 4 System Setup ssa ear OO E et 102 6 3 5 Loopb ck Test ida S S pda ten 102 6 3 6 Alarm Setups ica o be DP en PEDE d e pre en M 103 6 3 7 Upgrade Firmware icu ette i pes ET e 104 6 3 8 DTE board Return to Default ipae e e Pp itt ipee rre arcis 104 6 3 9 Card R set hee oe e pP D p Rae pp 105 6 4 DTECX 50 SUB MENU 5 5i eT pp UO ne ln rt huis Bee te esha ete 106 6 4 1 DTE CONPUSULAUON CEDE 106 6 4 2 DTE Statista e etai ER Ge RE ER REGES 107 6 4 3 ren ERE EE E ege HERE 107 6 4 4 MACH Cx EE 108 6 4 5 Loopback Tests RU o reete hae e IRAE EEUU EU tannins 108 6 4 6 DUAE ER 109 6 4 7 Upgrade Firmwares bete en ist E tr RE Re eee 109 6 4 6 Clear Current Port Performance Data sosie 110 6 4 9 Return to Default eet erre ne en Rd 110 6 4 10 Reset Current DTE Bo rd onc e e e men ree bee RE net des 110 6 5 ATM FRAME RELAY SUB MENU sisi 111 6 5 1 Hou
44. 16 d lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt Press D to enable this map as the current map LOOP AM3440 C System Setup New map 18 42 33 12 04 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Last activated TSI Map MAP 1 Change to TSI Map MAP 1 This item will be ignored if anyone of the following is enabled TSI Map switch start hr min Mapl DISABLE 00 00 Map2 DISABLE 00 00 Map3 DISABLE 00 00 Map4 DISABLE 00 00 lt lt Press ESC to return to previous menu gt gt 72 Chapter 6 Terminal Operation LOOP AM3440 C lt lt Press ESC key to return to Main Menu or enter a ULZHUNRIOQGHE EH WU gt V Controller Setup 18 43 02 System SNMP Setup Password TSI Map Setup Select a New TSI Map Copy a TSI Map to Another Clear a TSI Map Command Line Init New Card Clear Empty Slot Link Backup Function QDS1 1 1 Protection DSO SNCP Setup PDH Ring Protection PDH Ring Diagnostic SNTP Setup TELNET SSH Setup Power Setup command gt gt 12 04 2008 LOOP AM3440 C ARROW KEYS lt lt CURSOR MOVE TAB Last activated TSI Map Change to TSI Map This item will be ignored if anyone System Setup ROLL OPTIONS New map 18 44 38 MAP 1 MAP 3 TSI Map switch start hr min Mapl DISABLE 00 00 Map2 DISABLE 00 00 Map3 DISABLE 00 00 Map4 DISABLE 00 00 Press ESC to return to Contr
45. 205 BPV 25 e1 es 206 ES 26 e1 uas 207 UAS 27 e1 css 208 CSS 28 ais ins 209 AIS INSERT 9 QT1 Card Vendor Spec Assigned Alarm type 20 t1 yel 221 YEL 21 t1 ais 222 AIS 22 t1 los 223 LOS 23 t1 lof 224 LOF 24 t1 bpv 225 BPV 25 t1 es 226 ES 26 t1 uas 227 UAS 27 t1 css 228 CSS 10 G 703 Card Vendor Spec Assigned Alarm type 20 g703 los 541 LOS 165 Chapter 10 Appendix D LOOP AM3440 C ALARM TRAP INFORMATION 11 G shdsl Card Vendor Spec Assigned gshdsl htuc los loop1 301 gshdsl htuc los loop2 302 gshdsl htur los loop 1 303 gshdsl htur los loop2 304 gshdsl htuc e1t1 los lof 305 gshdsl htur e1t1 los lof 306 gshdsl htuc es 15m loop1 307 gshdsl htuc es 15m loop2 308 gshdsl htur es 15m loop1 309 gshdsl htur es 15m loop2 310 gshdsl htuc e1t1 es 15m 311 gshdsl htur e1t1 es 15m 312 gshdsl htuc ses 15m loop1 313 gshdsl htuc ses 15m loop2 314 gshdsl htur ses 15m loop1 315 gshdsl htur ses 15m loop2 316 gshdsl htuc e1t1 ses 15m 317 gshdsl htur e1t1 ses 15m 318 gshdsl htuc es 24h loop1 319 gshdsl htuc es 24h loop2 320 gshdsl htur es 24h loop 1 321 gshdsl htur es 24h loop2 322 gshdsl htuc e1t1 es 24h 323 gshdsl htur e1t1 es 24h 324 gshdsl htuc ses 24h loop1 325 gshdsl htuc ses 24h loop2 326 gshdsl htur ses 24h loop1 327 gshdsl htur ses 24h lo0p2 328 gshdsl htuc e1t1 ses 24h 329 gshdsl htur e1t1 ses 24h 330 gshdsl sealing current 331 gshdsl mclk loss 332 gshdsl htuc dte rts 333 gshdsl
46. 3 18 2 18 d aa 4 303 19d 4 3 19 3 19 d 4d 4 3 4 20d 4 3 20 4d 20 d T S 01 Su ow 3 5 21d 4 3 21 5d 21 d Clear No 6 d 41 13 46 22d 4 3 22 22 d d v d 7 d 4 3 7 23 d 4 3 23 7 d 23 d 8d 4 3 8 24d 4 3 24 8 d 24 d 9d 4 3 9 25 d 4 325 9 d 25 d Source 10d 4 3 10 26 d 4 3 26 10 d 26 d Slot 11 4 3 LT 27d 4 Lid 27 d Port P3 12 gd 4 3312 28d 4 3 28 12 d 28 d TS 01 13d 4 3 13 29 d 4 3 29 13 d 29 d 14d 4 3 14 30d 4 3 30 14 d 30 d Confirm Yes 15d 4 3 15 31 d 329532 1520 Lo 16 d 32 d 16 d 32 d lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt This is a sample TSI map for the Master unit The source port is Slot 1 Port 1 and the target port is Slot 1 Port 2 LOOP AM3440 C System Setup MAP 15 01 17 12 12 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO MAP 1 Target DTE A Source DTE A Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS Slot 1 Port P2 2 Xd dec LT d ld 4 3 d 17d 4 35 17 DUE 01 2 18 d 2d 4 3 2 18d 4 3 18 19 d 3d 4 3 3 19 d 4 3 19 4d 20 d 4 4 3 4 20d 4 3 20 T S 4 01 5rd 21 r Sd 4 3 B 218 321 Clear 6 d 22 d 6d 4 3 6 22 d 4 3 22 d v d qo 23 04 23 7 23 d 4 223 8 d 24 d 8d 4 3 8 24d 4 3 24 9 d 25 9 4 3 9 2S m8 oA 33225 Source 10 d 26 d l0d 4 3 10 26d 4 3 26 Slot 1 11 d 27 d 11 4 SAT 27d
47. 64KBps Clock Normal Data Normal RTS Active TTM Off V 54 x OLE INTERFACE X 21 lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 96 Chapter 6 Terminal Operation 6 2 18 DTE Status To enter the DTE status menu press I The following screen appears SLOT 3 DTE PORT 1 Unit Status 18 35 27 03 01 2001 Ese LOCAL esse DTE M1 existed YES RTS LOSS 1 YES EXT CLK LOSS NO DSR YES CTS NO DCD YES DTR NO RTS NO Loopback Status DTE Loopback OFF BERT OFF lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 6 2 19 Alarm History Press H to view the alarm history SLOT 3 DTE PORT 1 11 19 07 0370272001 Port State Count Alarm jJ 0 DISABLE 2 O 0 DISABLE 3 O 0 DISABLE 4 0 DISABLE 5 0 DISABLE 6 O 0 DISABLE lt lt ESC to return to previous menu SPACE to refresh U key to change unit gt gt 97 Chapter 6 Terminal Operation 6 2 20 System Setup Press S to setup the system ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS em LOCAL Channel 0 Rate 64KBps Clock Normal Data Normal RTS Active TTM Off v 54 Off INTERFACE V 35 lt lt ESC key to previous menu SPACE bar to another page gt gt 6 2 21 Loopback Test To enter the Loopback and Test screen press L The following screen appears SLO
48. 7 Clear a TSI Map Controller Menu gt S System Setup gt F Clear a TSI Map This function is to clear the selected TSI map setting LOOP AM3440 C System Setup Clear 19 02 13 11 25 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Clear TSI Map MAP 1 lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt 6 2 7 8 Command Line Controller Menu gt S System Setup gt L Command Line This function is for FAE support use Press then press ENTER the system will list all available commands Then key in a desired command to get the detail description To return to the Controller Setup menu press q Press get help or QUIT return 19 02 46 Nov 25 08 Available Commands quit help passcode ether arp ping fbank fboot upgrade syslog auto_save inactive pdh_spring capture fae upload resume 19 02 54 Nov 25 08 gt gt help Commands Support cud e SSS ase gt Quit command support help meme gt This help message ether status clear Display Clear ethernet status arp clrarp gt Print Clear ARP table PLAN Sense ee eoe eee deis gt Ping an ip address fbank 2 2 24 gt Display or set firmware bank in Flash fooot se gt Download boot up code DANGER syslog gt Dump system log auto save sec 2 gt Display or set au
49. C and Y BOX with RJ48C 155 Figure 9 3 Line Protection for Quad Card sise 157 List of Tables Table 2 1 Power Connector for Main Unit 16 Table 2 2 Gonsole Port ioter Dat UR t net aU 16 Table 2 3 Ethernet tte PCR UB Ot oH b 16 Table 2 4 Alarm Relay Circuit Contact State When Alarm Setup is Enable 17 Table 2 5 Alarm Relay Circuit Contact State When Alarm Setup is 17 Table 2 6 FUSE Relay Connector toi tie Eg terre RE ER RR TRISTE REF RAINER PERF Erie 17 Table 2 7 Circuit Proection for Mini Quad E1 Interface eene 18 Table 2 8 V 35 DB25 DTE Port Pin 20 Table 2 9 V 36 EIA530 DB25 DTE Port Pin Definition 21 Table 2 10 X 21 V 11 and DB15 DTE Port Pin 21 Table 2 11 RS232 DB25 DTE Port Pin Definition sise 22 Table 2 12 DB25 Mini Quad E1 Pin Definition ss 23 Table 2 13 Default Software Configuration ss 23 Table 3 1 Console Port Settings de de biete die e Lebe trente ede a ede 28 Table 3 2 Alam Action Table igi d dece De salve e ele ie edd kde read ded 29 Table 3 3 System Alarm Type Table sise 29 Table 3 4 DTE PORT Alarm Type 30 Table 3 5 Alarm Type Numbers cei EL ede eid ne e eiie ent ci dee
50. D 52 6 2 6 System Alarm Setup Ji ee eset ee Er OR DU OE IU HER gute eO ERR sees 75 6 2 9 Firmware Transfer qe eo ER eget Co m ep oper OE ERR AE get 76 6 2 10 Retrieve COnfigur atiOn 85 6 2 11 Clock Source Setup e Ee e p sentent EE ini 87 6 2 12 Bit Error Kate Testis t HESSE eq GNE Sd YOUR EE den OS RS ELE RR eines er 93 6 2 13 Alarm Cut Off x teen ie ERE C ner xt e tte tre Rhe a perte t ee GH 94 6 2 14 Clear Alarm Queue EE 94 6 2 15 Controll r Return to Default cn eri ie er ee RE e ERU er eua 94 6 2 16 Controll r Reset e RE Echo ERE Re RE EE ERR 94 6 2 DTE GV 39 SUB MENU se dishes des hese reete ao etes ce edi a dre Ve 94 6 2 17 DTE Configutrdtion ee rete e t Pe TR D eb e nn ERN rcr cbe ya ent 95 6 2 18 DTE Status itane nee esie t ee pen 97 6 2 19 pius mM 97 6 2 20 System Setup a i eene ee er Den eere rt erre a eie e e rie EA 98 6 2 21 Loopback Test ec eee ien eere tee ere qe eee eges reae e tre t eue 98 6 2 22 Alarm SCLUP sus 99 6 2 23 Upgrade Firewates nissan ne pie 99 6 2 24 Clear Current Port Performance Data ss
51. ENABLE ATM LOC ENABLE FR LKD ENABLE lt lt Press ESC key to return to previous menu gt gt 125 Chapter 6 Terminal Operation 6 5 9 2 Alarm Setup FR to FR SLOT D ATM FR El Port Alarm Setup 17 25 38 07 21 2002 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS TYPE THRESHOLD ALARM YEL ENABLE AIS ENABLE LOS ENABLE LOF ENABLE BPV 10E 5 ENABLE ES 001 ENABLE UAS 001 ENABLE CSS 001 ENABLE FR LKD ENABLE lt lt Press ESC key to return to previous menu gt gt 6 5 10 AM3440 C TSI MAP Setup Before the ATM FR card can be set up the TSI map for the card must be set up first From the main controller menu choose S System Setup to do this Enter the required information where the cursor appears in the left hand side column of the screen In the example below three screens are shown in sequence to display the choices available to the user 6 5 10 1 Map slot D ATM FR to slot B E1 card LOOP AM3440 C System Setup MAP 10 08 40 09 13 2002 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO MAP 1 Target ATM FR Source El NON CAS Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS Slot a DY S2555 Ssss SAEs Port 1 d B 1 17 d Td D 1 7 d TES 01 25d B 2 18 d 2 d D 2 8 d Bu B 3 19 d 2 8 D 3 9 d 4 d B 4 20 d 4 d D 4 20 d T S 04 2d d 21 d Cle
52. L Active a Tributary E es Backup 7 77 Cross Connect Tributary Active gt Backup 1 1 gt gt Active a Tributary eme gee Eee Backup TT Cross Connect Tributary Active 7 Backup 148 Chapter 7 Appendix A Link Backup Function 7 2 Physical Requirement The physical configuration of a Link Backup Function should consist of one AM3440 unit and at least 2 E1 T1 cards for mini slot or at least 2 FOM cards FOM card for mini slot or 1FOMA for single slot 7 3 Setup Procedure To configure the Link Backup Function in the follow procedure 1 Same configure on both link backup cards 2 Configure Link Backup Function 3 Configure the TSI Map see TSI Map setup in chapter 6 Configure Link Backup Function Command Path Controller Menu gt S System Setup gt G Link Backup Function P Description This function is to setup the 1 1 or 1 1 protection for single E1 T1 FOM cards in mini slots and 1FOMA cards in single slot 1 From the System Setup Backup screen choose to active deactive for the backup function Detail fields are explaining in the following table 2 When the setting finished press ESC to save the configuration A prompt will ask Are you sure Y N Press Y You will automatically return to the Controller Setup screen Note Both backup links shall have the same FRAME and CAS setting Please return to controller menu and go to unit s
53. Performance Report ss s cree ete o To nain 140 6 6 3 Unit Line Availability t er epe peri 141 6 6 4 Unit ye RARO Do beens 142 6 6 5 Unit Stats oe pet ete SERRE dees ae eee 142 6 6 6 Unit Alarm History cesses eie ne pee fees e a ee eth E ie 143 6 6 7 Unit Alarm Queue cm ee eie cr dee ete Pei nee aene ee RTS 143 6 6 8 Unit Loopback Setups us aste D debeam Da rete debet 144 6 6 9 Unit System Setup rte D qe ae deo REI E 144 6 6 10 Unit Clear Performance Data ss e e eme i dett Hep opti pte ea 145 6 6 11 Urt Alarm SUD iua eo CD ae EU REND ER RAUM D d qe air 145 6 6 12 Unit Clear Alarm Queue amp History sise 146 6 6 13 Uit Upgrade Firmwares ndi eite te pent 146 6 6 14 Unit Load Default Gonfiguration re e tc tne tratte eu ee 147 6 6 15 LIN a2 147 7 APPENDIX A LINK BACKUP EFUNCTIONssssenrenesnennenenenenenennnsnnenerenensenesse 148 7 1 INTRODUCTION edm tee det ettet 148 7 2 PHYSICAL REQUIREMENT asin tiene iden de age den shavers tege dieat tee dri die 149 7 3 SETUP PROCEDURE tant ten 149 8 APPENDIX INBAND seta suse ta sons
54. Press Z to reset the system the download is done 6 2 10 Store Retrieve Configuration Under the Controller Menu press V to store or retrieve the current configuration as the following screen shows Use TAB key to select STORE or RETRIEVE press ENTER The current selection will be highlighted by an asterisk Store Configuration LOOP AM3440 C Store Retrieve Configuration 11 56 20 12 05 2008 gt gt Select STORE RETRIEVE Then the system will prompt the following message shown in the bottom line Enter Y to confirm the setting or to abort LOOP AM3440 C Store Retrieve Configuration 11 56 49 12 05 2008 gt gt Select STORE RETRIEVE gt gt Store Current Configuration Y N 85 Chapter 6 Terminal Operation Press Y from the above screen then enter password in the following screen The default password is LOOP LOOP AM3440 C Store Retrieve Configuration 11 56 49 12 05 2008 gt gt Select STORE RETRIEVE gt gt Enter password XXXX Then press ENTER from the above screen the configuration is saved LOOP AM3440 C Store Retrieve Configuration 11 56 49 12 05 2008 gt gt Select STORE RETRIEVE gt gt Saving Retrieve Configuration Use arrow keys to move the cursor at RETRIEVE which will be highlighted by an asterisk LOOP AM3440 C Store Retrieve Configuration 11 58 40 12 05 200
55. R Redundant Board Information K Clock source Setup P gt Performance Report T gt Bit Error Rate Test LOG MISC U gt Choose a Slot A Alarm Cut Off F gt Log Off SETUP MISC Menu X gt Clear Alarm Queue O gt Log On SETUP MISC Menu Y gt Controller Return to Default 2 Controller Reset gt gt SPACE bar to refresh or enter a command gt 80 Chapter 6 Terminal Operation LOOP AM3440 C File Transfer 11533550 L27 0572008 gt Download Mainboard Firmware gt Upload Mainboard Firmware gt Download Configuration gt Upload Configuration gt Download Mainboard Boot up gt Copy Firmware to Redundant DAU Ww w lt lt Press ESC key to return to Main Menu or enter a command gt gt A 2 Press A from File Transfer menu to download mainboard firmware see below screen LOOP AM3440 C Download Firmware 11 44 54 12 05 2008 ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn BACKSPACE to edit Firmware 1 Version V7 04 03 09 10 2008 Firmware 2 Version V7 05 01 10 28 2008 Current Firmware Bank 2 Next Boot Firmware 2 22 Server 000 000 000 000 Firmware File Name lt lt Press ESC key to return to previous menu gt gt A 3 If the Current Firmware Bank is 2 download AM3440 T RUN to bank 1 After the download is completed then reboot the system If the Current Firmware Bank is 1 pu
56. SL PO TS PO TS D SL PO TS Slot 1 Port Bl ld 4 3 1 17d 4 3 70 1d 17 d ToS 0d 2d 4 3 2 18d 4 3 18 2d 18 d 3d 4 3 3 19d 4 3 19 3 d 19 d 4d 4 3 4 20d 4 3 20 4d 20 d T S 24 5d 4 3 5 21d 4 3 21 5d 21 d Clear No 6d 4 3 6 22d 4 3 22 6 d 22 d d v fd 7d 4 3 7 23 d 4 3 23 23 0 8 d 4 3 8 24d 4 3 24 8 d 24 d 9d 4 3 9 25 d 4 325 9 25 d Source l0d 4 3 10 26d 4 3 26 10 d 26 d Slot 1 11 d 4 27d 4 3 27 11 d 27 d Port P3 12d 4 3 12 28d 4 3 28 12 d 28 d 1205 e O 15 8 b o3 13 29 d 4 3 29 13 d 29 d 14 d 4 3 14 30d 4 3 30 14 d 30 d Confirm Yes 15d 4 3 15 31 d 4 331 15 d 16 32 d 16 d dc lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt This is a sample TSI map for the Master unit The source port is Slot 1 Port 1 and the target port is Slot 1 Port 2 LOOP AM3440 C System Setup MAP 15 13 40 12 12 2008 Please Input decimal number 1 32 BACKSPACE to edit MAP NO MAP 1 Target DTE A Source DTE A Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS Slot 1 Sh a Port 5 P2 2 Hd d 17 d ld 4 3 T 17d 4 3 17 TS OT 2d 18 d 2d o3 2 18d 4 3 18 3d 19 d 3d 4 3 3 19d 4 3 19 20 d 4d 4 3 4 20 d 4 320 T S 23 5 d 21 d 4 3 B5 21 4 3 21 Clear No 22 d 4 3 6 22 4 322 sud 7 d 23 d 7d 4 3 7 23d 4 3 23 8 d 2
57. Slot 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 FR Channel 0000 00 00 00 00 00 00 00 00 00 00 00 00 00 lt lt Press ESC key to return to previous menu gt gt 134 6 5 11 3 3 Chapter 6 Terminal Operation Frame Relay Management Setup FR to FR Select the FR MAN item on the Port System Setup menu Use this management setup to tell the protocol details of the ATM network The logical channel number can be 1 to 31 The meanings of the parameters are the same as for FR to ATM SLOT D ATM FR E Port FR Management Setup ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS CH Active Protocol Direction T391 1 1 FR U User 0 1 YES FR ITU Network 0 2 YES HDLC 3 YES FR ITU Network 0 4 YES HDLC 9 NO FR ITU Network 0 6 NO FR ITU Network 0 7 NO FR ITU Network 0 8 NO FR ITU Network 0 9 NO FR ITU Network 0 10 NO FR ITU Network 0 11 NO FR ITU Network 0 12 NO FR ITU Network 0 13 NO FR ITU Network 0 14 NO FR ITU Network 0 15 NO FR ITU Network 0 16 NO FR ITU Network 0 lt lt Press ESC key to return to previous menu gt gt 6 5 11 3 4 Column Heading Options O1 O1 O1 O1 Connection Table Setup FR to FR Select the CONN TAB item on the Port System Setup menu Use this management setup to link the connection table to that of the Frame Relay network The channel number can be 1 to 31 All the numerical entries must
58. Slot Y Unit Load Default Config P gt Choose Port Z Unit Reset F gt Log Off SETUP MISC Menu O gt Log On SETUP MISC Menu E Return to Controller Main Menu gt gt Please input El Port 1 4 then press ENTER 138 Chapter 6 Terminal Operation This port menu is for mini Quad E1 Port 2 SLOT A MQuad El PORT 2 Port Menu TO 281742 1072242004 Version SW S1 CO 10 20 2004 DISPLAY SETUP 1 gt Unit 1 Hour Perf Report L Unit Loopback Setup 2 Unit 24 Hour Perf Report S Unit System Setup A Unit Line Availability K Unit Clear Performance Data C gt Unit Configuration M gt Unit Alarm Setup gt Unit Status X gt Unit Clear Alarm Queue amp History H gt Unit Alarm History D Unit Upgrade Firmware Q gt Unit Alarm Queue LOG MISC U Choose Other Slot Y gt Unit Load Default Config P gt Choose Port Z Unit Reset F gt Log Off SETUP MISC Menu O gt Log On SETUP MISC Menu E Return to Controller Main Menu gt gt SPACE bar to refresh or enter a command gt 6 6 1 Unit 1 Hour Performance Report Press 1 from Port Menu to view the 1 hour performance report Use TAB key to select register type USER or LINE The current selection will be highlighted by an asterisk SLOT A MQuad E1 PORT 2 Port Menu 10 28 12 10 27 2004 gt gt Select Register Type USER LINE After pressing ENTER
59. TS D Slot 1 d B 17 d 1 1d 09 2 d B 2 18 d T 2242 3 d B 3 19 d 1 mud 4 d B 4 20 d 1 4 d T S 04 5 d A 21 d 1 6 d A 2 22 6 d d v 7d A 3 23 d 7 d 8 d A 4 24 d 8 d 9 d T 1 25 9 4 Source 10 d 1 1 2 26 d 10 Slot 2 1 11 d 1 1 3 27 d 11 d Port P1 12 a 1 4 28 d 12 d qu ms 01 lc 4 29 d L5 dw 14 d 30 d 14 d Confirm Yes 15 d 31 d i9 8 16 d 16 d Press ESC to return to Controller Setup menu SL PO 0 08 40 V 35 TS PO TS then Press D to active 09 13 2002 D SL PO TS Oa Qu 0 0 QOO OO gt gt 127 Chapter 6 Terminal Operation 6 5 10 4 Map slot D ATM FR to HDLC Inband Channel LOOP AM3440 C System Setup MAP 10 08 40 09 13 2002 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO MAP 1 Target ATM FR Source HDLC Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS Slot D a me nu a mm WAS a Tp ae c ur AERE ROLE Port 1 1h d ld D 13 ToS 2 1153 2 d B 2 18 d 3d B 3 19 4 4 d B 4 20 d ro Xu 5d A 21 d Clear No 6 d A 2 22 d d v d 7 d A 3 23 d 8 d A 4 24 d 9 d 1 1 25 Source 10 d T 1 2 26 d Slot HD 11 d T 1 3 27 d Port 12 d 1 1d 4 28 d TES 01 13 d HD 29 d 14 d 30 d Confirm Yes 15 d 31 d 16 d lt lt Press ESC to return to Controller Setup menu then Press D to active gt
60. as below SLOT 1 DTE PORT 1 Unit Configuration 15 05 24 12 10 2008 mmm LOCAL Channel Rate 64KBps Clock Normal Data Normal RTS Active TTM 3 Off v 54 Off INTERFACE X 21 lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 6 3 2 DTE Status Under the Port Menu press I to view the unit status the screen will show as below SLOT 1 DTE PORT 1 Unit Status 15 05 49 12 10 2008 eee LOCAL DTE El existed YES RTS LOSS YES EXT CLK LOSS NO DSR YES CTS NO DCD YES DTR NO RTS NO Loopback Status DTE Loopback BERT OFF lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 101 6 3 3 Alarm History To view the alarm history press H from the Port Menu The screen will show as below Chapter 6 Terminal Operation Port SLOT 1 DTE PORT 1 State Count 0 lt lt ESC to return to previous menu Alarm History Alarm DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE 15 06 19 12 10 2008 SPACE to refresh U key to change unit gt gt 6 3 4 System Setup To setup the system press S from the Port Menu The screen will show as below RTS TTM V 54 INTERFACE X 21 Channel Rate Clock Data SLOT 1 DTE PORT 1 ARROW KEYS CURSOR MO
61. be coordinated with the Frame Relay network The meanings of the table columns are as follows T392 N391 006 006 006 006 006 006 006 006 006 006 006 006 006 N392 Meaning Logical channel number 10 18 27 09 13 2002 N393 Data Link Connection Identifier within the egress E1 T1 port Committed Information Rate Committed Burst Size DLCI DLCI in egress E1 T1 port CIR Be Information rate committed on E1 T1 side y Actual allocated bandwidth Excess Burst Size 135 Chapter 6 Terminal Operation SLOT D Please Input 1 10 BACKSPACE to edit ATM FR El Port Connection Table Setup 10 20 01 09 13 2002 CH DLCI lt gt DLCI CIR Bc Be index 4 04 HDLC 019 0064 0064 0000 126 0 0 0 0 0 0 0 127 0 0 0 0 0 0 0 128 0 0 0 0 0 0 0 t t 16 16 250 0 25 6 256 0 2 2 0 17 256 256 256 0 3 3 18 18 64 64 64 0 4 4 0 18 64 64 64 0 5 0 0 0 0 0 0 0 6 0 0 0 0 0 0 0 7 0 0 0 0 0 0 0 8 0 0 0 0 0 0 0 9 0 0 0 0 0 0 0 10 0 0 0 0 0 0 0 lt lt Press ESC key to return to previous menu available DLCI 16 991 gt gt The procedure for modifying this table is the same as for the FR ATM protocol 6 5 12 Clear Alarm Queue Press X to clear alarm queue and history then enter Y or N to confirm it LOOP AM3440 C Controller Menu Slot ADs LAS Serial Number 123472 Hardware Version Ver G Software Ve
62. bps 1x n x32 x 4Mbps for total of all 64 WAN ports 10 100 BaseT x 2 RJ45 RIP I RIP Il OSPF Static PPP IPCP BCP MLPPP HDLC Frame Relay and Cisco compatible HDLC NAT NAPT DHCP Ping Trace route Rate limit 8 LAN ports Max 64 WAN ports Each WAN port has data rate n x 64K bps 1x n x32 x 8Mbps for total of all 64 WAN ports 10 100 BaseT x 8 RJ45 RIP I RIP Il OSPF Static PPP IPCP BCP MLPPP HDLC Frame Relay and Cisco compatible HDLC NAT NAPT DHCP Ping Trace route Rate limit Terminal Server Interface Connecotr Ports Data Rate Layer 2 Protocol of RS232 Async One DB 44 converseion cable to one DB 9 and two DB 25 connecotrs One Async RS232 port two Async Sync RS232 ports The two Async Sync ports can be configured independently as Asynchronous or Synchronous Async 1 2kbps 2 4kbps 4 8kbps 9 6kbps 19 2kbps 38 4kbps Sync 64 kbps Raw data SLIP Layer 2 Protocol of RS232 Sync PPP Terminal Server Function Router Function Supports Telnet RIP I RIP II Static Route Fiber Optical Interface 1FOM A Interface Source Wavelength 50 Km reach MLM Laser Line Code Scrambled NRZ 1310 50 nm 1550 40 nm Detector Type PIN FET Protection Optional 1 1 APS Optical Fiber Interface Characteristics Optical Module Fiber Direction Wavelength nm Connector Distance km Single Dual uni direction 1310 SC Subscriber Connector 30 1310 SC Subscriber Connector 50 13
63. cleared up LOOP AM3440 C Controller Setup 16 03 55 11 27 2008 A gt System gt SNMP Setup gt Password gt TSI Map Setup gt Select a New TSI Map gt Copy a TSI Map to Another gt Clear a TSI Map gt Command Line nit New Card Clear Empty Slot Link Backup Function 0051 1 1 Protection DSO SNCP Setup gt PDH Ring Protection gt PDH Ring Diagnostic gt SNTP Setup TELNET SSH Setup gt Power Setup umazddugmwodocnut um5uuuotus lt lt Press ESC key to return to Main Menu or enter a command gt gt Press F from the above Controller Setup menu to clear the previous TSI map Then press ESC to return to the Controller Setup menu LOOP AM3440 C System Setup Clear 16 06 18 11 27 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Clear TSI Map MAP 3 lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt LOOP AM3440 C ees COntrolLler setup 18 41 04 11 27 2008 System SNMP Setup Password TSI Map Setup Select a New TSI Map Copy a TSI Map to Another Clear a TSI Map Command Line nit New Card Clear Empty Slot Link Backup Function QDS1 1 1 Protection DSO SNCP Setup PDH Ring Protection PDH Ring Diagnostic SNTP Setup TELNET SSH Setup Power Setup Umu duuumwmiodocnmnut utuoqtuu r b DEL PE aie al V VV VV V VV VV V VV
64. d 3 d 19 4 4 d 20 d 5 d 21 d 6 d 22 d 7 d 23 d 8 d 24 d 9 22 25 d 10 d 26 d 27 d 12 d 28 d LX 29 ud 14 d 30 l5 d 31 d 16 d au d lt lt Press ESC to return to previous menu gt gt Note D displays either d v data voice 45 Chapter 6 Terminal Operation 6 2 1 5 Power Fan Status To view the screen of Power Fan Status press E from the Controller Configuration Menu The default value is 48 V DC Of the two kinds of power type 48V DC and AC the system of AM3440 will not note the power type so the user needs to choose it manually LOOP AM3440 C Power Fan Status 15 20 32 09 09 2011 Power 1 Status Power 2 Status Fail or no power 48V 100W DC Total power consumption Estimation 14W Fan 1 Status Fan 2 Status Fail or not exist Fail or not exist ESC key to return to previous menu SPACE bar to refresh Note Power consumption table shows below to estimate total power consumption and detect power card status Power consumption does not include 48 DC power supply consumption Condition Total Power DC Power Alarm Trap Warning message Consumption Supplies gt 75W amp No FAN Failure External fan tray is necessary Please add a fan tray Single 100W Power supplies over loading Please remove plugged in Dual 100W Power protection not supported cards or upgrade to 150W ui 100W 150W Power protec
65. detected alarm are solved To check the alarm status see the Q Alarm Queue Summary screen The alarm status clear indicates the problem of the alarm s are solved PERIOD The user has to set up a time limit first and the default setting is 2 seconds That means the alarm relay will return to normal condition after 2 seconds the alarm is detected MANUAL When alarms are detected and reported to CTRL card the user has to cut off all the alarms manually by pressing the ACO button on the controller s front panel or by activating A Alarm Cut off from the main menu Then the alarm relay will return to the normal state DISABLE The alarm relay will remain disabled when alarms occur LOOP AM3440 C System Alarm Setup 18 47 36 12 04 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Alarm Action ALARM DISABLE RELAY PERIOD PERIOD s 2 Alarm Type ALARM CUT OFF SLOT INACTIVE 5 LOT START UP LOC LOSS D B D B D B D B LIN SWITCH D B MAP SWITCH DISAB D B D B D B M R POWER ALARM TYPE MISMATCH DUAL CPU ALARM MANAGEMENT ALM EE tot Ld Ed Ed Dd Dd Dd D Ed Dd d lt lt Press ESC key to return to previous menu gt gt 75 6 2 9 Firmware Transfer Chapter 6 Terminal Operation Under the Controller Menu press W to enter in the screen of File Transfer as below Press A to download mainboard firmware B to upload
66. directions The working line outside line in the diagram below travels in a counter clockwise direction The protection line inside line travels in a clockwise direction While the is no theoretical limit to the number of nodes in a ring each node needs 2 3 seconds to stabilize SSM clock switching after a break occurs In our sample diagram below we have used five nodes l Port A E 4T1 Ld Management PC HDLC Inband Inband Mamnagement is set up by ET B Port C assigning1 DSO 64K for inband management purposes on the TSI ET TS1 24 4T1 timeslot map of each AM 3440 ACunit CIk A Internal TS1 2 Port C 1534 AT1 P CE 4T1 et 7 2 Sis 2 a TS5 24 TS1 24 Clk A B 4T1 176 Chapter 12 Appendix F Setting up an AM3440 C PDH Shared Protection Ring T1 12 2 Setup Instructions 1 Nodes Set up four nodes each of which consists of a Loop AM3440 C device equipped with four Quad T1 cards Each of these nodes will be referred to as Slaves 2 Master Unit Set up a Master unit which consists of a Loop AM3440 C device equipped with three Quad T1 cards and a single Router card 3 VT 100 Each AM3440 C can be set up individually using a VT 100 monitor 4 Clocks The clocks must be set up on each of the AM 3440 C units If you have no SSM source at the MASTER unit set the clock for this unit at NORMAL SLAVE un
67. in Slot 4 It will be used as a Slave and will perform the protection function 9 2 3 Setting up a VT 100 Monitor Use a DB9 cable to connect the front Console Port of the AM3440 C to either COM Port 1 or COM Port 2 of the PC you are using as a VT 100 monitor It doesn t matter which Com Port you connect to NOTE Many newer PCs use USB Ports If your computer has a USB port rather than COM ports you will need to purchase a commercially available PC USB to DB9 conversion cable These cables come with software which when loaded in a PC will allow you to send keyboard commands through the PC s USB Port to the DB9 Console Port of the AM3440 C 9 2 4 Step by Step Quad E1 Card Circuit Protection Setup The sample screens below provide step by step instructions for setting up Quad E1 Circuite Protection In our sample setup we installed Quad E1 cards in slot 3 and slot 4 The card in slot Z3will be working slot and slot 4 will be stand by Go to Controller Menu gt S System Setup gt Q QDS1 1 1 Protection select Setup and press Enter The Setup menu is to setup the protection modes for each protection pair and ports LOOP AM3440 C QDS1 1 1 Protection 18 07 22 09 13 2011 gt gt Select Setup Status On the Setup Screen there are six selection for the user to setup such as disable circuit line non revertive line revertive 1 1 non revertive and 1 1 revertive The sample below is to setup the port 1 of sl
68. previous menu SPACE bar to refresh gt gt 43 Chapter 6 Terminal Operation 6 2 1 2 Clock Source Press B from the Controller Configuration Menu the screen of Clock Source Setup will show as below Note that the external clock type in this example is E1 LOOP AM3440 C Clock Source Setup Normal Mode 10 56 57 11 10 2008 Master Clk Source INTERNAL Second Clk Source INTERNAL Current Clock MASTER CLK Clk Recover Mode MANUAL Clock Status NORMAL Ext Clock Type Dual External Clock Protection Disable lt lt ESC key to return to previous menu SPACE bar to refresh gt gt Note 1 Clock Hold Over option is for 3E1 plug in card only 2 When the option of Clock Hold Over is On and the current clock is MASTER CLK the Hold Over State in the screen will show NORMAL When clock source loss occurs the Hold Over State in the screen will show Hold Over 3 sure the external clock type corresponds to the physical card type If the system is linked to T1 but the Ext Clock is set to E1 setup failure may occur The sample screen below shows a T1 clock type LOOP AM3440 C System Setup CLOCK Normal Mode 16 21 16 12 10 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Master Clk Source INTERNAL Second Clk Source INTERNAL Current Clock MASTER CLK Recover Mode MANUAL Clock Status NORMAL Ext Clock Type z TL Dual External Clo
69. the following further setup will be for the ATM protocol For Frame Relay protocol see later sections 6 5 11 2 1 Port System Setup SLOT ARROW D ATM FR T1 CURSOR MOVE TAB ROLL OPTIONS EYS RAME ODE EL IS NBAND NTF BO Port System Setup 17 35 29 03 23 2002 ESF Interface ioc B8ZS Protocol ON Channel Map FRAMED LITIIIITIIITIITITILIIlITIII1 OFF LONG HAUL 0 dB lt lt ESC key to return to previous menu SPACE bar to refresh gt gt SLOT ARROW EYS FRAME ODE RC D ATM FR El Port System Setup 10 24 07 09 13 2002 CURSOR MOVE TAB ROLL OPTIONS ON Interface El HDB3 Protocol ATM ON Channel Map ON is Kt es Et pi Eig Fp ag EE a 15141521 FRAMED OFF OFF Sa4 75 Ohm lt lt Press ESC key to return to previous menu gt gt 6 5 11 2 2 Channel Map Setup 129 Chapter 6 Terminal Operation Select the CH MAP item on the Port System Setup menu Use this channel map to tell the ATM FR card what time slots are combined to be a logical frame relay channel The logical channel number can be 1 to 31 A 00 will indicate an idle time slot SLOT D ATM FR El Port Channel Map Setup 10 24 58 09 13 2002 Please Input 1 10 BACKSPACE to edit Time Slot 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 FR Channel 01 01 01 00 00 00 00 00 00 00 00 00 00 00 00 00 Time Slot l4 1
70. triggered when the condition of the power supply changes ON OFF For example when the power is ON NC will open relative to COM and NO shorted relative to COM If the fuse in the power supply card is brown OFF NC will be shorted relative to COM and NO will be open relative to COM Table 2 6 FUSE Relay Connector Circuit NC COM NO COM Condition System Power Off Open System Power On Short Chapter 2 Installation 2 3 5 Jumper Location for Mini Quad E1 Mini QE1 Card LL Figure 2 4 Jumper Location for Mini Quad E1 Interface Table 2 7 Circuit Proection for Mini Quad E1 Interface Jumper Circuit Protection 7 OFF 8 OFF 9 OFF 10 OFF Chapter 2 Installation 2 4 Configuration Setting 2 4 1 Software Configuration Setting There are three system configurations Factory default Current working User stored Link backup Factory default configurations are not changeable Each Loop AM3440 is shipped with all three configurations set to the factory default configuration The current working configuration which can be saved into nonvolatile memory as a user stored configuration can be changed at any time When the system is reset the previous configuration will be retrieved as the current working configuration The user stored configuration can be retrieved at any time User can retrieve the user stored config
71. two functions will not show on the VT100 menu 65 Chapter 6 Terminal Operation 6 2 7 14 PDH Ring Protection Follow the command path Main Menu gt S System Setup gt R PDH Ring Protection to access PDH Ring Protection Enable PDH ring protection and set up the swithching interval and station type LOOP AM3440 C PDH Ring Protection 12 13 36 03 15 2006 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS PDH Ring Protection Switching Interval Station MASTER Port 2 Port 3 Port 4 Slot Model lt lt Press ESC key to return to previous menu gt gt 6 2 7 15 PDH Ring Diagnostic Follow the command path Main Menu S System Setup PDH Ring Diagnostic to access PDH Ring Protection Sample Screen for PDH Ring Diagnostic LOOP AM3440 C PDH Ring Diagnostic 17 04 27 07 09 2009 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Slot Model Port 2 Port 3 Port 4 1 Quad El 2 HSE Geesien ESS lt 3 MEME Secco 222 4 MEE 1L nom S i E EERS 2 2 uwmEEEESESM lt lt Press ESC key to return to previous menu gt gt 66 Chapter 6 Terminal Operation 6 2 7 16 SNTP Setup Controller Menu gt S System Setup gt N SNTP Setup This function is SNTP server setup Simple Network Timing Protocol SNTP is an adaptation of the Network Time Protocol NTP used to synchronize computer clocks in the Internet
72. 0 C DSO SNCP Status 10 34 35 10 15 2009 DSO SNCP ENABLE Total DSO SNCP 5 Index Protected Primary Secondary Mode STOE Pork ES SIOE POSE ES Slot Port TS 1 01 W 1 1 01 2 1 01 Non revertible 2 A 02 W 1 1 02 2 T 02 Non revertible 3 A 03 W 1 1 03 2 1 03 Non revertible 4 A 04 W 1 1 04 2 1 04 Non revertible 5 A 05 W 1 1 05 2 1 05 Non revertible lt lt ESC key to return to previous menu SPACE bar to refresh gt gt Note d v means data or voice mode 6 2 2 Clock Source Configuration Controller Menu gt B Clock source Configuration This function shows the current clock source configuration info LOOP AM3440 C Clock Source Setup Normal Mode 11 43 17 11 12 2008 Master Clk Source INTERNAL Second Clk Source INTERNAL Current Clock MASTER CLK Recover Mode MANUAL Clock Status NORMAL Ext Clock Type S Dual External Clock Protection Disable lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 48 6 2 3 Alarm Queue Summary Controller Menu gt Q Alarm Queue Summary This function is to view the Alarm Queue Summary Chapter 6 Terminal Operation LOOP AM3440 C Management Management Management Management Management Management Management Management Management Management o O1 amp C ho pa SU SU SU SU SU SU SU SU SU SU PV PV PV PV PV PV PV
73. 000 0 0000 100 00 Current 24 Hour IS PLEBS uL SAR Sat Saree es SSS Sees ie se USER ES Last 96 15 Min Interval 01 08 gt lt lt TAB key to show Performance Report gt gt lt lt ESC key to return to previous menu SPACE key to refresh gt gt 6 5 3 Port Statistics Press A from the port menu the screen will show as below To view the statistics of ATM FR port by selecting statistics type The current selection will be highlighted by an asterisk SLOT D ATM FR El Port Statistics 17 28 15 07 21 2002 gt gt Select Statistics Type T1 El1 Line FR Statistics ATM Statistics 6 5 3 1 T1 E1 Line Availability SLOT D ATM FR El Port Line Availability 17 23 19 07 21 2002 Line Availability during Last 24 Hour Valid Seconds 621 seconds Available Seconds 621 seconds Unavailable Seconds 0 seconds Line Avaliability 1 00 0 lt lt ESC key to return to previous menu SPACE key to refresh gt gt 117 Chapter 6 Terminal Operation 6 5 3 2 Frame Relay Statistics Channel 1 SLOT D ATM FR El Port Frame Relay Statistics 1452333 0772172002 PVC Number 1 Total PVC T lt lt Input PVC 0 for channel summary or ESC to previous menu gt gt SLOT D ATM FR El Port Frame Relay Statistics 15 23 33 017421720902 Channel 1 1 DLCI 100 Recive
74. 10 FC Fiber Connector 30 1550 SC Subscriber Connector 20 1550 SC Subscriber Connector 100 Single Single bi direction master 1310 1550 SC Subscriber Connector 30 Single bi direction slave 1310 1550 SC Subscriber Connector 30 G SHDSL Line Interface Number of ports Line Rate for 4 channel G shdsl Line Rate for 2 channel G shdsl Line Code Connecotr Electrical Sealing current Clock Source 20r4 n x 64 Kbps n 3 to 31 n x 64Kbps n 3 to 15 16 TCPAM full duplex with adaptive echo cancellation RJ45 Unconditioned 19 26 AWG twisted pair Max 20 MA source current From System Line Chapter 1 Product Description Diagnostic Test G SHDSL Loopback To LINE To bus BERT QRSS DTE Interface X 21 Data Port 6 port DTE X 21 card 1 port DTE X 21 card Data Rate 56 or 64 Kbps n 1 to 32 Connector DB15S DTE Interface V 35 Data Port 6 port DTE V 35 card 1 port V 35 card Data Rate 56 or 64 Kbps n 1 to 32 Connector DB25S optional conversion cable DB25S to M34 connector DTE Interface V 36 Data Port 6 port DTE V 36 card Data Rate 56 or 64 Kbps n 1 to 32 Connector DB25S optional conversion cable DB25S to DB37 connector DTE Interface EIA530 RS449 Data Port 6 port EIA530 DTE card 1 port EIA530 card Data Rate 56 or 64 Kbps n 1 to 32 Connector DB25S optional conversion cable DB25S male to DB37 female connector for RS449 DTE Interface RS232 Data Port 1 port RE232 card
75. 150 Chapter 8 Appendix B Inband Management 8 Appendix B Inband Management 8 1 Introduction The advantage of Inband Management is that saves money because management is through the line itself and a separate line is not needed for management functions The disadvantage is that if anything happens to break the management channel you cannot get it back In Inband Management the management function is inserted into the working line Using the Router card management of a local as well as one or more remote Loop products The diagram below illustrates inband application The user can use router card to share one or more 64 Kbps time slot for SNMP management Each 64 Kbps time slot has enough bandwidth to manage four AM3440 Thus up to four AM3440 can share a single 64 Kbps bandwidth for SNMP management Data Router card ofthe AM3440 C 1 Time slot Inband Management allows Inband Management through the network AM3440 C 1 UNIT Management 5 Wi W2 Ws Router LAN 10 100 BaseT f One TS AM3440 C 2 UNIT pet Management AM3440 C H H LES E d E 2223 AM3440 C AM3440 C 4 Figure 8 1 Inband Management Diagram 151 Chapter 8 Appendix B Inband Management 8 2 Inband Management Setup Procedure To configure the Inband Ma
76. 4 3 27 Port Pl 12 d 28 d 12 d 4 3 12 28d 4 3 28 TS 01 13 d 29 d 13d 4 3 13 29d 4 3 29 14 d 30 d 14d 4 3 14 30d 4 3 30 Confirm Yes 15 d 31 d 15d 4 3 15 31 d 4 331 16 d 32 8 16 d 22 8 lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt 173 Chapter 11 Appendix E Setting up an AM3440 C PDH Shared Protection Ring This is a sample TSI map for the Master unit The source port is Slot 1 Port 2 and the target port is Slot 1 Port 3 LOOP AM3440 C System Setup MAP 15 02 47 12 12 2008 Please Input decimal number 1 32 BACKSPACE to edit MAP NO MAP 1 Target DTE A source DTE A Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS Slot 1 Port 2 P3 1 17 d 2 A dt 17 d Tu 001 2 0 18 d 2d 18 d 3 d 19 d so 19 d 4d 20 d 4d 20 a TS 22101 5 q 21 d 5d 21 d Clear No 22 d 22 d d v d 7 d 23 d 7 d 23 d 8 d 24 d 8 d 24 d 9 d 25 d 9 d 25 d Source 10 d 26 d 10 d 26 d Slot 1 11 d 27 d 11 d 27 d Port P2 12 d 28 d 12 d 28 d T S 01 13 29 13 29 14 d 30 d 14 d 30 d Confirm Yes 15 d 31 d 15 d Sg 16 d 32 d 16 d 32 4 lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt This is a sample TSI map for the Master unit Note that this map sets up the HDLC Inband Management mappi
77. 4 Yes Yes Yes No 9 Yes Yes Yes No 25 Yes Yes Yes No 0 Yes Yes Yes No 26 Yes Yes Yes No 1 Yes Yes Yes No 207 Yes Yes Yes No 2 Yes Yes Yes No 28 Yes Yes Yes No S Yes Yes Yes No 2 9 Yes Yes Yes No 4 Yes Yes Yes No 30 Yes Yes Yes No 5 Yes Yes Yes No 31 Yes Yes Yes No 6 Yes Yes Yes No 32 Yes Yes Yes No Yes Yes Yes No 33 Yes Yes Yes No 8 Yes Yes Yes No 34 Yes Yes Yes No 8 Yes Yes Yes No 25 Yes Yes No 20 Yes Yes Yes No 36 Yes Yes Yes No lt lt ESC key to return to previous menu SPACE key to refresh gt gt 6 5 6 3 2 ATM Status E1 SLOT D ATM FR El Port Status 15 46 07 07 24 2002 LINE LOS 2 YES LOF FAS RCV AIS NO RCV RAI NO XMT AIS NO XMT RAI RAI BPV ERROR COUNT 0 ES ERROR COUNT 0 SSE Sly c a PATTERN TRANSMITTED OFF NEAR END LOOPBACK OFF lt lt ESC key to return to previous menu SPACE key to refresh gt gt 123 Chapter 6 Terminal Operation 6 5 7 Alarm Queue Press Q form the port menu to view the alarm queue SLOT D ATM FR El Unit Alarm Queue 17324757 OF J 2172002 12 Port Sees 17 13 34 07 21 2002 2 Port AIS LItL3234 OF F217 2002 3 Port A FR LKD 17 13 33 07 21 2002 lt lt ESC key return to previous menu or SPACE bar to refresh gt gt 6 5 8 Loopback Test 6 5 8 1 Frame Relay T1 Under the port menu press L to setup the loopback test for the AT
78. 4 d 8d 4 3 8 24d 4 3 24 9d 25 d 9d 4 3 9 25 0 4 33 25 Source 10 d 26 d l0d 4 3 10 26d 4 3 26 SPOE cv 11 d 27 d 13 d4 27 d 4 3 27 Port Pl 12 d 28 d 12d 4 3 12 28d 4 3 28 TS x 01 13 d 29 d 132g 4 3 X3 29d 4 3 29 14 d 30 d 14d 4 3 14 30d 4 3 30 Confirm Yes 15g 31 d 15d 4 3 15 31 d 4 331 16 d 32 8 6 42 32 d lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt 179 Chapter 12 Appendix F Setting up an AM3440 C PDH Shared Protection Ring T1 This is a sample TSI map for the Master unit The source port is Slot 1 Port 2 and the target port is Slot 1 Port 3 LOOP AM3440 C System Setup MAP 15 14 17 12 12 2008 Please Input decimal number 1 32 BACKSPACE to edit MAP NO MAP 1 Target DTE A Source DTE A Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS Slot E 1 SSSSSSS Port Pp3 1 d 17 d 2 udo UE 17 d Tase 2 07 2d 18 d 2d 18 d 19 19 4d 20 d 4d 20 d T S 24 5 d 21 d 5 d 21 d Clear No 6 d 22 d 6 d 22 d d v iod 7 d 23 d 7 d 23 d 8 d 24 d 8d 24 d 9 d 9 d 82 Source 10 d 26 d 10 d 26 d Slot 1 11 d 27 d 11 d 27 d Port P2 12 d 28 d 12 d 28 d TES OT 13 d 29 d 13 d 29 d 14 d 30 d 14 d 30 d Confirm Yes 15 d 31 d 15 d S418 16 d 32 d 16 d az 8 lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt T
79. 8 gt gt Select STORE RETRIEVE gt gt Retrieve Last Stored Configuration Y N Press ENTER from the above screen Then press Y to retrieve last stored configuration or N to abort it LOOP AM3440 C Store Retrieve Configuration 11 58 40 12 05 2008 gt gt Select STORE RETRIEVE gt gt Retrieve Last Stored Configuration Y N Press Y from the above screen then enter password in the following screen The default password is LOOP LOOP AM3440 C Store Retrieve Configuration 12 09 05 12 05 2008 gt gt Select STORE RETRIEVE gt gt Enter password XXXX 86 Chapter 6 Terminal Operation Then press ENTER from the above screen the configuration is retrieved LOOP AM3440 C Store Retrieve Configuration 12 09 05 12 05 2008 gt gt Select STORE RETRIEVE gt Retrieving 6 2 11 Clock Source Setup For Normal Clock Mode Under the Controller Setup menu press A to get in System Setup SYSTEM menu as below screen shows Use arrow keys to mvoe the cursor at Clock Mode item and TAB key to choose Normal option LOOP AM3440 C System Setup SYSTEM 12 14 18 12 05 2008 ARROW KEYS CURSOR MOVE Please Input hh mm ss mm dd yyyy BACKSPACE to edit System Time Date L2214 518 12 05 2008 Device Name LOOP AM3440 C Network NI EN IPAddress SubnetMask Frame LB Timer LAN OFF 000 000 000 000 000 000 000 000 Et
80. 9 PO 20 21 22 23 24 25 2 6 427 298 239 730 91 FR Channel 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 lt lt Press ESC key to return to previous menu gt gt 6 5 11 2 3 Frame Relay Management Setup FR to ATM Select the FR MAN item on the Port System Setup menu Use this management setup to tell the protocol details of the ATM network The logical channel number can be 1 to 31 The meanings of the parameters are as follows Column Heading CH Options 1 to 31 Meaning Logical channel number Active YES NO Activated by user An idle frame relay channel Protocol ITU ANSI Using Q 933 Annex A protocol Using T1 617 Annex D protocol Direction User Network Bidirection Acts as user side device periodically issues polling messages to network side Acts as network side device waits for polling messages from user side This channel can issue polling messages and respond to polling messages T391 Polling Interval 5 30 seconds The interval between Status Inquiry message from user to network else error counted T392 Response time 5 30 seconds The max allowed interval between Status Inquiry and network response else error counted N391 PVC Polling Interval 1 255 seconds The interval between PVC Status Inquiry message from user to network else error counted N392 Error count Determine service affecting condition by detecting N392 errors i
81. 9 25 d B 25 9 d A 9 25 d A Source 10 d B 10 26 d B 26 10 d A 10 26d A Slot B 11 d B TI 27 d B 27 11 d A 11 27 d A Port 12 12 28 d B 28 12 d A 12 28 d A T S M 13 d B 13 29 d B 29 13d A 13 29 d A 14 d B 14 d B 30 14 d A 14 d A Confirm Yes 15d B 15 31d B 31 15d A 15 31d A 16 d B 16 16 16 32 d lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt NOTE For voice cards users do not have to select the time slot T S data The system will automatically adjust the T S number according to the port number you set up T S 01 is for port1 T S 02 is for port 2 and T S 10 is for port 10 The T S time slot number will always correspond to the port number After complete the TSI Map Setup press ESC key then the following screen shows up and V command main menu gt gt Press any key to continue Please use D command next screen LOOP AM3440 C System Setup MAP to activate map as current map to save maps to Flash memory 18 12 42 08 01 2011 After you change the TSI Map you need to go to Select a New TSI Map to activate the new map 60 Chapter 6 Terminal Operation 6 2 7 5 Select a New TSI Map Controller Menu gt S System Setup gt D Select a New TSI Map This function is to allow change the active map from previous setting Sample below shows the new setting on Map 1 will replace the previous Map 1 by select MAP 1 on Ch
82. AJOR ES 001 MAJOR UAS 001 MAJOR CSS 001 MAJOR lt lt Press ESC key to return to previous menu gt gt 145 Chapter 6 Terminal Operation 6 6 12 Unit Clear Alarm Queue amp History Under Port Menu press to clear alarm queue and history then press Y or N to confirm it SLOT A MQuad El PORT 2 Port Menu 10 27 33 10 27 2004 Version SW S1 CO 10 20 2004 DISPLAY SETUP Unit 1 Hour Perf Report L Unit Loopback Setup 2 Unit 24 Hour Perf Report S Unit System Setup A Unit Line Availability K Unit Clear Performance Data GC gt Unit Configuration M Unit Alarm Setup gt Unit Status X gt Unit Clear Alarm Queue amp History H Unit Alarm History D gt Unit Upgrade Firmware Q Unit Alarm Queue LOG MISC U gt Choose Other Slot Y gt Unit Load Default Config P Choose Port Z Unit Reset Log Off SETUP MISC Menu O gt Log On SETUP MISC Menu E Return to Controller Main Menu gt gt Clear alarm queue of SLOT A are you sure Y N 6 6 13 Unit Upgrade Firmware Press D to download firmware then the screen will show as below Use arrow keys to move the cursor and SPACE key to edit LOOP AM3440 C Download Firmware 10 27 49 10 27 2004 ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn BACKSPACE to edit Bank 1 Firmware Ver S1 C0 10 20 2004 Good Bank 2 Firmware Ver
83. AM 3 IE VP WVLO E 13 2 1 SITE SBEECTIONZz 3 niei e HE D entente net cen c qn need ciae a 13 22 MECHANICAL INSTALLATION eo re eo eee ep ted tees doge tret ev de e gere Re 13 2 ELEGIRICAE EE Eee nn eve d Co DER 13 2 3 1 Chassis GrOuUNCING RE 14 2 3 2 Electrical Installation Guide cccccccccccscesccccccccccsssssesceccccccsssseccecccessususeccecccessuuseccececeusauseecessecesuaeceeseceaes 14 2 3 3 Al rm RELAY cette Gabe Ree ENS 17 2 3 4 F seRelay PEE 17 2 3 5 Jumper Location for Mini Quad El iii 18 2 4 CONFIGURATION SETTING de tree 19 2 4 1 Software Configuration Settings ss 19 2 4 2 Replacement of Plug in ee tH ee babs e ie en AS tee 19 OPERATION Pcr D 26 3 1 QUICK START FOR LOOP AM iles eniti ne ies te de dete cde de de rat ee Re 26 3 1 1 POWeF ON ERA RE Le NM peo nee I nacen 26 3 1 2 Load Default i iei p ee REOR Se E GR I i ERR UE eT ret 26 3 1 3 Using Front Panel v oU UO ei eter i RO Ue e De ie ER EUER Ped Yet 27 3 1 4 Using Terminal e p ee HU e ack OE UR ERE P MESE Tete 27 3 1 5 Configuration Se
84. ATM SLOT D ATM FR T1 Port Frame Relay Status 17 24 42 07 21 2002 CH Link CH Link 1 Up 1 7 nactive 2 nactive 18 nactive 3 nactive 19 nactive 4 nactive 20 nactive 5 nactive 21 nactive 6 nactive 22 nactive 7 nactive 23 nactive 8 nactive 24 nactive 9 nactive 25 nactive 0 nactive 26 nactive 1 nactive 27 nactive 2 nactive 28 nactive 2 nactive 29 nactive 4 nactive 30 nactive 5 nactive 31 nactive 6 nactive lt lt ESC key to return to previous menu SPACE key to refresh gt gt 6 5 6 2 2 FR to FR SLOT D ATM FR T1 Port Frame Relay Status 16 03 29 03 27 2002 CH Link CH Link 1 1 Up 16 nactive 1 Down 17 nactive 2 nactive 18 nactive 3 nactive 19 nactive 4 nactive 20 nactive 5 nactive 21 nactive 6 nactive 22 nactive 7 nactive 23 nactive 8 nactive 24 nactive 9 nactive 2 5 nactive 10 nactive 26 nactive LL nactive 27 nactive 12 nactive 28 nactive 13 nactive 2 9 nactive 14 nactive 30 nactive 15 nactive 31 nactive lt lt ESC key to return to previous menu SPACE key to refresh gt gt 122 Chapter 6 Terminal Operation 6 5 6 3 ATM Status 6 5 6 3 1 ATM Status T1 SLOT D ATM FR 1 Port ATM Status ATM LINE SYNC 17 24 50 07 21 2002 Active AIS RDI LOC Active AIS RDI LOC 1 Yes Yes Yes No 21 Yes Yes Yes No 6 Yes Yes Yes No 22 Yes Yes Yes No 7 Yes Yes Yes No 23 Yes Yes Yes No 8 Yes Yes Yes No 2
85. C key ignore and return ENTER key accept change gt gt 57 Chapter 6 Terminal Operation V3 View Based Access Control Model Setup 1 Controller Menu gt S System Setup gt S SNMP Setup gt D V3 View Based Access Control Model Setup 1 Press D to setup context and group the user should be in a group The default group name is initial and scurity name is name of user LOOP AM3440 C SNMP Setup VACM 18 12 44 11 25 2008 Context empty Security to Group 1 7 Security Model V3 USM Security Name loopmd5 Group Name initial Status Active Storage NonVolatile UP DOWN gt context group LEFT RIGHT gt prev next gt gt A gt add D gt delete gt gt lt lt ESC gt return to menu lt lt F gt find ENTER gt edit V3 View Based Access Control Model Setup 2 Controller Menu gt S System Setup gt S SNMP Setup gt E V3 View Based Access Control Model Setup 2 Press E to edit Access and View for VACM every group can define their own security level and have read and write access to view Item shows reserved means that the item shown is not currently supported by this version View contains 1 or more MIB sub trees The V3 driver will check incoming packages Context Prefix Context Match Read View Name Write View Name Notify View Name Status 2 reserved reserved one reserved Active lt lt ESC gt return to previous menu lt
86. DM SESS Current 15 Min 100 00 99 469 0 5305 0 5305 0 0000 6 6666 0 3921 1st Nearest 15 Min MEE EL E CELL 2ndy Nearest ud5 cMin occ ISSO ecce See sees Sa queer EET Sse 3rd Nearest 15 Min rM LM CELL Ll LA 4th Nearest Jemen SSS See swiss SR feeds RS ER am SES Re RS ees ciet us Valid 15 Min Intervals in Current 24 Hour Interval O0 SAS SEFS SES SBES SES SDM CSS Current 24 Hour Hrs dr LM C SE SES eres Se d d 0 26 2004 guae RSS Sener SSeS oS eee e ere 0 25 2004 ES ES REA See Shoe DS 0 24 2004 DR RE SE ER A aR oe 0 23 2004 RS pee LE SR LS le CR SRE re ee sm ee 0 22 2004 E LE aa aM E le E 0 21 2004 X much Uer e Seer RSS eie mp Ce ims rn ie eee ei iei epe 0 20 2004 poesie BRR gei uon re gc Si alien SAN P moe SALE p lt lt TAB key to show Performance Report gt gt ESC key to return to previous menu SPACE bar to refresh 6 6 2 Unit 24 Hour Performance Report Press 2 from Port Menu to view the 24 hour performance report Use TAB key to select register type USER or LINE press ENTER Then move the cursor to select the desired parameter The current selection will be highlighted by an asterisk SLOT A MQuad E1 PORT 2 Port 24 Hour Perf Report 10 28 12 10 27 2004 g
87. Data Rate 56 or 64 Kbps n 1 2 Mapping Any sequential time slots DTE Interface RS232 X 50 mux 5 port Data Port 5 port RS232 cards with X 50 plug in subrate with subrate mux MUX a 5 independent RS232 or b 5 subrate RS232 X 50 muxed to 64K Data Rate Mode a 5 independent RS232 1 2K 2 4K 4 8K 9 6K 19 2K 38 4K 48K 64K SYNC 1 2K 2 4K 4 8K 9 6K 19 2K ASYNC Mode b 5 mux together 1 2K 2 4K 4 8K 9 6K SYNC 1 2K 2 4K 4 8K 9 6K ASYNC NOTE Connector DB25S DTE Interface RS232 X 50 mux 8 port Data Port 8 port RS232 cards MUX Maximum 5 subrate port per 64K bps Data Rate Mux mode 0 6K 1 2K 2 4K 4 8K 9 6K Asynchronous Independent mode 0 6K 1 2K 2 4K 4 8K 9 6K 19 2K 38 4K Mux mode 0 6K 1 2K 2 4K 4 8K 9 6K Synchronous Independent mode 0 6K 1 2K 2 4K 4 8K 9 6K 19 2K 38 4K 48K 64K Port Number Card Type 1 2 3 4 5 6 7 8 FEES Async Async Async Async Async Async Async DB Se MERS Async Sync Async Sync Async Async Sync Async Sync Async Async Async Connector Eight RJ48 port 1 to port 8 DB44 port1 port2 port3 DB44 port4 port5 port6 RJ48 port7 and RJ48 port8 Conversion Gable A three into one conversion cable adapts the DB44 connector to 3 connecters one DB9S and two DB25S Electrical RS232 Interface DCE Note 1 Up to 19 2 Kbps achieved by oversampling at 64 Kbps Co directional Interface Interface ITU G 703 64 Kbps co directional interface Con
88. Device Name LOOP AM3440 C Network NI EN IPAddress SubnetMask Frame LB Timer LAN ON 010 003 023 010 255 255 000 000 Ethernet 4 WAN ON 020 001 001 002 255 255 000 000 HDLC 00000001 Gateway Interface LAN Gateway IPAddr 000 000 000 000 Inband Uses Slot D or 12 Note Slot D or 12 port 4 can t use unframe mode CONSOLE port Baud Rate Data Length Stop Bit Parity XON XOFF TSI map Clock TSI Function 1 1 Bidirection Clock Mode Idle Signalling 1010 lt lt Press ESC key to return to previous menu gt gt Note NI Network Interface EN Enable DIS Disable LB Timer Loopback Timer The system will automatically assign the trap IP to LAN IP or WAN IP according to the trap system IP and Network interface you set up Below is the table of trap source IP condition under different LAN and WAN settings Option Setting Trap Source IP LAN EN WAN EN LAN Off Off No trap Off With IP On LAN IP Without IP WAN IP 0 0 0 0 On Off LAN IP On On LAN IP WAN Off Off No Trap Off On WAN IP On Off With IP WAN IP Without IP LAN IP 0 0 0 0 On On WAN IP Option Trap System IP option on VT Trap IP Trap and Community screen Setting NI Network Interface option on System Setup screen 56 Chapter 6 Terminal Operation V3 User Based Security Model Setup Controller Menu gt S System Setup gt S SNMP Setup gt C V3 User Based Security Model Setup
89. For SNMPv3 user must setup USM and VACM For USM it is used to setup user authentication and privacy Press C to setup User Based Security Model There are 12 digit number for Engine ID The user s name is loopmd5 and the password is loop1234 LOOP AM3440 C SNMP Setup USM 18 10 58 11 25 2008 My Engine Engine ID 00000337000000007 000001 Boots ed Total User 2 User 01 Engine ID 0000033700000000C601E250 User Name loopsha Auth Protocol SHA Auth Key C9C79ACF5783F6CC99B16E8B39EEBABGAAEO0A4AIE Priv Protocol No Priv Key Status Active Storage NonVolatile lt lt ESC return to previous menu LEFT RIGHT gt prev next user F gt find user gt gt lt lt E gt edit engine ENTER gt edit user C gt clone user A gt add user D gt delete gt gt If you press Enter an edit screen will appear The user must enter a password A delay will occur because of transfer time to record the key LOOP AM3440 C SNMP Setup USM 18 11 29 11 25 2008 ARROW KEYS CURSOR MOVE BACKSPACE to edit ESC to abort My Engine 3 Engine ID 0000033700000000C601E250 Boots Total User 2 User 01 E E 3 Engine ID 0000033700000000C601E250 User Name loopmd5 Auth Protocol MD5 Auth Password Priv Protocol No Priv Password Status Active Storage NonVolatile Skip password will not change current key lt lt ES
90. LBO 0 dB FDL FDL Protected DISABLE Master lt lt Press ESC key to return to previous menu gt gt 6 TSI Function The TSI function for all the AM3440 C devices must be set at 1 N Multicast This setting is highlighted on the sample setup screen below LOOP AM3440 C System Setup SYSTEM 15 09 42 12 12 2008 ARROW KEYS CURSOR MOVE Please Input hh mm ss mm dd yyyy BACKSPACE to edit System Time Date 15 09 42 12 12 2008 Device Name LOOP AM3440 C Network NI EN IPAddress SubnetMask Frame LB Timer LAN OFF 000 000 000 000 000 000 000 000 Ethernet WAN OFF 000 000 000 000 000 000 000 000 HDLC 00000001 Gateway Interface LAN Gateway IPAddr 000 000 000 000 CONSOLE port Baud Rate 38400 Data Length 8 Bits Stop Bit t l Bit XON XOFF XOFF TSI map Clock TSI Function 1 N Multicast Clock Mode SSM Idle Signalling 1010 lt lt Press ESC key to return to previous menu gt gt 178 Chapter 12 Appendix F Setting up an AM3440 C PDH Shared Protection Ring T1 7 Map Setup You must do your mapping for the Master Unit This is a sample TSI map for the Master unit The source port is Slot1 Port 3 and the target port is Slot1 port 1 LOOP AM3440 C System Setup MAP 15 12 45 12 12 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO MAP 1 Target DTE A source DTE A Target PO TS D SL PO TS PO TS D SL PO TS PO TS D
91. LOCK SSM Mode 11 03 50 09 29 2011 ARROW KEYS CURSOR MOVE Please Input 0 9 A F BACKSPACE to edit First Clock Source SLOT 1 Pl Clock Hold Over OFF Second Clock Source EXTERNAL Third Clock Source INTERNAL Current Clock INTERNAL Clock Status NORMAL Internal Clock SSM Message 2 External Clock SSM Message 4 External Clock Type 1 750hm Field Setting Options First Clock Source NONE INTERNAL EXTERNAL Line Interface Second Clock Source NONE INTERNAL EXTERNAL Line Interface Third Clock Source NONE INTERNAL EXTERNAL Line Interface Internal Clock SSM Message Input 1 9 A E SSM code please refer to table below External Clock SSM Message SSM code please refer to table below External Clock Type E1 75ohm E1 1200hm T1 2048KHz 75ohm 2048KHz 1200hm Note Line Interface includes Quad E1 T1 mini Quad E1 FOM and 1FOMA card 90 Chapter 6 Terminal Operation Clock Source Setting Illustration AM3440 Unit 2 AM3440 Unit 1 Unit 1 clock source setting First Clock Source slot1 port3 Second Clock Source slot port 1 Third Clock Source internal E1 Network Unit 2 clock source setting First Clock Source slot1 port1 Second Clock Source Internal Third Clock Source None The Unit 1 setting screen shown below SLOT 1 P3 is the current clock and top priority for the quality level of its receive Sabit is 4 So the quality level of its transm
92. Link Backup Function gt QDS1 1 1 Protection DSO SNCP Setup PDH Ring Protection gt PDH Ring Diagnostic SNTP Setup TELNET SSH Setup gt Power Setup UGnZHU3WwWwOQGnt 5t ugocotu lt lt Press ESC key to return to Main Menu or enter a command gt gt The PDH Ring Protection screen will appear LOOP AM3440 C PDH Ring Protection 12 13 36 03 15 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS PDH Ring Protection Switching Interval Station Slot Model Port 2 Port 3 i o jc sEce fece D WE uc 1 Quad T ENABLE ENABLE DISABLE DISABLE 2 5555588537 ER ARR 555245 3 bo TS MM MMS 4 SERESES SRSESES nzeiszir VASE 5 res Less ie lt lt Press ESC key to return to previous menu gt gt You must now repeat steps 7 and 8 for each of the AM3440 C Slave units in order to complete the PDH Shared Protection Ring setup procedure 181 Chapter 13 Appendix G AM3440 C Power Consumption 13 Appendix G AM3440 C Power Consumption There are two types of power modules 48 Vdc 100W and 100 to 240 Vac 80W The tables below list the power consumption of the controller card and the plug in cards This information is used to calculate the total power consumption Table 13 1 Power Consumption of AM3440 C Plug in Cards For 48 Vdc 100W and 100 to 240 Vac 80W Slot Plug in Cards 48 Vdc 100W Power Module 100 to 240
93. Loopback Test Pattern Front Panel Controller LED Indicators Physical Electrical Dimensions Power Temperature Humidity Mounting Line Power Supply Power Consumption Certification Electrical RS232 Connector DB9 female User Interface Meuy driven VT 100 1 port Connector RJ45 10 100 Base T SNMPv1 v3 Telnet SSH Inband 64 Kbps support HDLC PPP Optional Last 24 hours performance in 15 minute intervals and last 7 days in 24 hour summaries Network user and remote site Reports include E1 Bursty Errored Second Severe Errored Second Degraded Minutes Also available in Statistics 96 Containing 200 alarm records which record the latest alarm type location and date amp time Bursty Seconds Severely Errored Second Degraded Minutes E1 T1 interface Line Loopback Payload Loopback Local Loopback For Controller 220 4 215 4 21 1 1 29 1 and 4 bye user define pattern Power ACTIVE ALARM A B C D slots SYNC TEST LOF BPV RAI AIS 438 x 132 x 224 mm WxHxD Single Dual 48 Vdc 36 to 75 Vdc 100 Watts max Single AC 100 to 240 Vac 50 60 Hz 0 55 C 0 95 RH non condensing Desk top stackable 19 23 rack mountable N A Max 57 Watts EN55022 Class A EN50024 EN300 386 FCC Part 15 Class A IEC60950 1 CS 03 EN60950 1 Compliance ITU G 703 G 704 G 706 G 732 6 736 G 823 G 826 G 711 G 775 O 151 V 11 V 28 V 54 IETF SNMP v 3 11 Chapter 1 Product Description Specificat
94. M FR T1 interface SLOT D ATM FR Port Loopback Test 17 43 55 03 23 2002 ARROW KEYS CURSOR MOVE ENTER KEY ITEM SELECT NEAR END LOOPBACK 3 MORE LOCAL PLB LLB SEND LOOPBACK ACTIVATE CODE TO FAR END IN BAND AT amp T P ANSI P ANSI L SEND LOOPBACK DEACTIVATE CODE TO FAR END IN BAND AT amp T P ANSI P ANSI L SEND TEST PATTERN OFF ORSS FULL L IN 8 STATUS lt lt Press ESC key to return to previous menu gt gt 124 Chapter 6 Terminal Operation 6 5 8 2 ATM Frame Relay E1 Under the port menu press L to setup the loopback test for the ATM FR E1 interface SLOT D ATM FR El Port Loopback Test 15 44 49 07 24 2002 ARROW KEYS CURSOR MOVE ENTER KEY ITEM SELECT NEAR END LOOPBACK gt OFF LOCAL PLB LLB SEND LOOPBACK ACTIVATE CODE TO FAR END PAYLOAD LINE SEND LOOPBACK DEACTIVATE CODE TO FAR END PAYLOAD LINE SEND TEST PATTERN OFF PRBS FULL STATUS lt lt Press ESC key to return to previous menu gt gt 6 5 9 Alarm Setup Under the port menu press M to setup alarm 6 5 9 1 Alarm Setup FR to ATM SLOT D ATM FR El Port Alarm Setup 17 45 51 03 23 2002 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS TYPE THRESHOLD ALARM YEL ENABLE AIS ENABLE LOS ENABLE LOF ENABLE BPV 10E 5 ENABLE ES 001 ENABLE UAS 001 ENABLE CSS 001 ENABLE ATM LOS ENABLE ATM AIS ENABLE ATM RDI
95. NI EN IPAddress SubnetMask Frame LB Timer LAN ON 192 168 014 189 255 255 255 000 Ethernet WAN OFF 010 010 012 002 255 255 255 000 HDLC 00000001 Gateway Interface LAN Gateway IPAddr 192 168 014 254 CONSOLE port Baud Rate 9600 Data Length 8 Bits Stop Bit Parity NONE XON XOFF XOFF TSI map Clock TSI Function 1 1 Clock Mode SSM Idle Signalling 1010 gt gt Change configuration Y N Note to save please use V command 89 Chapter 6 Terminal Operation Then exit from the above menu after keying Y to confirm the latest system configuration Go to Quad E1 s Port Menu Under the Port Menu press S to get in the Port System Setup menu Use arrow key to move the cursor at the FDL item and TAB key to select SSM option SLOT 2 Quad E1 PORT 1 Port System Setup 15 13 51 06 25 2004 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS FRAME ON CODE HDB3 CRC ON RAI ON AIS FRAMED CAS OFF SIGNALLING TRANS CGA NORM 005 BUSY Sa bit Sa4 IDLE D5 Protected CIRCUIT Master MASTER INTF 75 Ohm lt lt Press ESC key to return to previous menu Then back to the Controller Menu press K to do clock source setup Then the following screen will show up This menu is allowed to set up first second and third clcok sources The SLOT 1 P1 means port 1 of slot 1 LOOP AM3440 C System Setup C
96. NTF 120 Ohm lt lt Press ESC key to return to previous menu gt gt Note When user does Inband setup slot D port 4 cannot do unframed mode setup 144 Chapter 6 Terminal Operation 6 6 10 Unit Clear Performance Data Press from Port Menu to clear performance data the screen will show as below Press Y to confirm the commend SLOT A MQuad El PORT 2 Port Menu 10 26 45 10 27 2004 Version SW S1 CO 10 20 2004 DISPLAY SETUP gt Unit 1 Hour Perf Report L Unit Loopback Setup 2 Unit 24 Hour Perf Report S Unit System Setup A Unit Line Availability K Unit Clear Performance Data C gt Unit Configuration M Unit Alarm Setup gt Unit Status X Unit Clear Alarm Queue amp History H Unit Alarm History D gt Unit Upgrade Firmware Q gt Unit Alarm Queue LOG MISC U gt Choose Other Slot Y gt Unit Load Default Config P gt Choose Port Z Unit Reset F Log Off SETUP MISC Menu Log On SETUP MISC Menu Return to Controller Main Menu FO gt Clear performance data are you sure Y N 6 6 11 Unit Alarm Setup To do alarm setup press M from Port Menu then the following screen will show up SLOT A MQuad El PORT 2 Port Alarm Setup 10 27 05 10 27 2004 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS TYPE THRESHOLD ALARM RAI MAJOR AIS MAJOR LOS MAJOR LOF MAJOR BPV 10E 5 M
97. Network Line Interface T1 Line Rate 1 544 Mbps 32ppm Output Signal Line Code AMI or B8ZS Framing Input Signal DSX 1 0 dB to 30 dB w ALBO Connector Network Line Interface E1 Line Rate 2 048 Mbps 50 ppm Framing Line Code AMI or HDB3 Connector Input Signal ITU G 703 Electrical Output Signal ITU G 703 Jitter Network Line Interface Mini 4E1 Line Rate 2 048 Mbps 50 ppm Framing Line Code AMI or HDB3 Connector Input Signal ITU G 703 Electrical Output Signal ITU G 703 Jitter Network Line Interface 3E1 Line Rate 2 048 Mbps 50 ppm Framing Line Code AMI or HDB3 Connector Input Signal ITU G 703 Electrical Output Signal ITU G 703 Jitter Function Support DSO SNCP Network Line Interface 4E1 Line Rate 2 048 Mbps 50 ppm Framing Line Code AMI or HDB3 Connector Input Signal ITU G 703 Electrical Output Signal ITU G 703 Jitter Network Line Interface 4T1 Line Rate 1 544 Mbps 32 ppm Output Signal Line Code AMI or B8ZS Framing Input Signal DSX 1 0 dB to 30 dB w ALBO Connector ATM Frame Relay Network Line Interface Supporting Network Interworking FRF 5 and service interworking FRF 8 Network Interface 1 Module T1 ATM UNI FR n x 64 Kbps n 1 to 24 E1 Module E1 ATM UNI FR n x 64 Kbps n 1 to 31 Up to 31 logical FR channels can be concentrated de concentrated to FR or ATM Service Ports T1 FT1 interface E1 FE1 interface Support HDLC to FR Support HDLC to ATM Supporting FR to FR multiplexin
98. P Setup TELNET SSH Setup gt Power Setup Um oZ oHG UU X OQO O0 H E o5 BOO UU lt lt Press ESC key to return to Main Menu or enter a command gt gt The PDH Ring Protection screen will appear LOOP AM3440 C PDH Ring Protection 12 13 36 03 15 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS PDH Ring Protection Switching Interval Station MASTER Slot Model Port Port 2 Port 3 Port 4 C MESSER S menus D CESR SEHEHLAO sas 1 Quad E ENABLE ENABLE DISABLE DISABLE 2 seeeeem semenan SERDES s 3 NEL LL 1 L oss 4 vEussetr ASS Eee 5 d HER HESSE ES lt lt Press ESC key to return to previous menu gt gt You must now repeat steps 7 and 8 for each of the AM3440 C Slave units in order to complete the PDH Shared Protection Ring setup procedure 175 Chapter 12 Appendix F Setting up an AM3440 C PDH Shared Protection Ring T1 12 Appendix F Setting up an AM3440 C PDH Shared Protection Ring T1 12 1 Overview PDH Shared Protection Ring can be an ideal solution for voice and data transmission networks in that if any one T1 connection is broken the voice and data communication system will still function This protection is made possible by mapping a loopback to where the channel came from In a PDH Shared Protection Ring each line is split in two
99. PV PV PV Alarm PORT LOG IN PORT TIMEOU PORT LOG IN PORT TIMEOU PORT LOG IN PORT TIMEOU PORT LOG IN PORT LOG IN PORT TIMEOU PORT LOG IN lt lt SPACE bar to refresh or ESC key Queue Summary return to main menu gt gt 1 6 2 3 oles D rQ rs o9 v2 DrodgiA 4 56 1 4 43 2 4 27 14 425095713 25 9 9 35 2512554 2 2 2 2 2 2 2 2 2 2 5 12 10 2008 0 2008 0 2008 0 2008 0 2008 0 2008 0 2008 0 2008 0 2008 0 2008 0 2008 6 2 4 Information Summary Controller Menu gt 1 Information Summary This function displays the current information of all plug in cards The unplugged means the the registered card has been unplugged To clear the unplugged wording from the screen go to Controller Menu gt S System gt J Clear Empty Slot and select the slot you want to clear The mismatch means the slot has replaced by another type of card which is different from registered card type When the word of mismatch show up press 5 command from the controller menu then enter command in the screen of Controller Setup in order to init a new plug in card LOOP AM3440 C 0 1 120ohm Information Summary Slot Alm Card Interface lt lt ESC key to return to previous menu Software Version Registered Card V3 04 06 01 2005 FE1 Router A SPACE bar to refresh 16 23 41 12 10 2008 unplugged unplug
100. Press ESC key to return to previous menu gt gt 99 Chapter 6 Terminal Operation 6 2 24 Clear Current Port Performance Data To clear current port performance data press X SLOT 3 DTE PORT 1 Port Menu 18 35 45 03 01 2001 gt gt Clear Performance Data Y N 6 2 25 Return to Default Press Y to return to default SLOT 3 DTE PORT 1 Port Menu 18 35 45 03 01 2001 Return to default are you sure Y N 6 2 26 Reset Current DTE Board To reset DTE board press Z SLOT 3 DTE PORT 1 Port Menu 18 35 45 03 01 2001 gt gt Reset Board 9 Y N 6 3 21 Sub Menu Under the Controller Menu press U to choose a slot for the DTE X 21 port Then the following screen will show SLOT 1 DTE PORT 1 Port Menu 14 56 10 12 10 2008 Version SW V2 01 02 04 27 2006 DISPLAY SETUP C DTE Configuration S gt System Setup DTE Status L Loopback Test H gt Alarm History M gt Alarm Setup G gt Upgrade Firmware LOG MISC F gt Log Off O Log On lt gt DTE board Return to Default U gt Choose Other Slot 2 gt Card Reset Choose DTE Port Return to Main Menu gt gt SPACE bar to refresh or enter command gt 100 Chapter 6 Terminal Operation 6 3 1 DTE Configuration Under the Port Menu press C to view the unit configuration the screen will show
101. ROW KEYS CURSOR MOVE TAB ROLL OPTIONS Master Clk Source INTERNAL Second Clk Source INTERNAL Current Clock MASTER CLK Recover Mode MANUAL Clock Status NORMAL Ext Clock Type Ts Dual External Clock Protection Disable lt lt Press ESC key to return to previous menu gt gt Configuration option Configuration Option Default Master_Clk Source INTERNAL EXTERNAL INTERNAL Second_Clk Source INTERNAL EXTERNAL INTERNAL Current Clock MASTER_CLK Second CLK INTERNAL MASTER_CLK Clk_Recover_Mode AUTOMATIC MANUAL MANUAL Clock Status NORMAL NORMAL Ext Clock Type T1 T1 Dual External Clock Enable Disable Disable Protection Note 1 SE1 plug in card will support the Clock Hold Over option It appears on VT100 screen when the controller hardware version J and software version 8 02 01 or newer version 2 The clock status in the screen shows NORMAL When clock loss occurs the screen will show LOSS 3 Clock Hold Over mode is configured to OFF The operation of system clock show as below When the master clock loss occurs the system clock will switch to secondary clock When the secondary clock loss occurs the system clock will switch to internal clock Clock Hold Over mode is configured to ON The operation of system clock show as below When the frequency accuracy of system clock is over 198 ppm the system clock will enter to Hold Over mode When the fr
102. S PO TS D SL PO TS PO TS D SL PO TS Slot B SSSSSSS555 SSSS5 SSSSSSSSSS Port 1 d A 1 17 d 1 d 17 d 01 2 18 d 2 d 18 d 38 19 d 3 d 19 4 d 20 d 4 d 20 d OU 21 52 21 Clear 6 d 22 d 6 d 22 d d v rod 7 d 23 7 d 23 d 8 d 24 d 8 d 24 d 9 d 25 d 9 d 25 q Source 10 d 26 d 10 d 26 d Slot A 11 d 27 d 11 4 27 d Port 12 d 28 d 12 d 28 d Tug 01 13 d 29 d 13 d 29 d 14 d 30 d 14 d 30 d Confirm Yes 15 od 31 d LS d 31 d 16 d 16 d lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt 71 Chapter 6 Terminal Operation Below setting is for mapping Slot A s time slot 01 to Slot 1 Port 1 s time slot 01 LOOP AM3440 C System Setup MAP 10 57 08 09 29 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO MAP 1 Target Quad E1 NON CAS Source E1 NON CAS Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS SLOE 1 Port J 1 d A 17 d 17 d Eq toU 2 18 2 d 18 d 3 d 19 3 19 d 4 d 20 d 4 d 20 d TS 01 5 d 21 d 5 od 21 d Clear No 6 d 22 d 6 d 22 d d v tod 2 6 2 d 4d 23 d B ed 24 d 8 5d 24 d 9 d 25 d 9 d 25d Source 10 d 26 d 10 d 26 d Slot A 11 d 21 d 11 d 27 d Port E 12 28 d 12 d 28 d TS 13 d 29 d L3 d 29 d 14 d 30 d 14 d 30 d Confirm Yes 15 d 21 d 15 48 34 8 16 d
103. SC alternately to bring the main menu into view Press O Log On to see the full menu Press S System Setup to review or change the configuration 3 1 5 Configuration Settings The entire configuration is shown when S System Setup is pressed To change any setting use the arrow keys to move to the target setting Then press the TAB key repeatedly to cycle to the desired setting for any selected parameter 3 2 System Operation 3 2 1 Date Loop AM is equipped with a RTC Real Time Clock User can change the current date and time as necessary RTC also can manage leap year To save RTC battery life the RTC is activated by the manufacturer just before shipping The RTC battery has a 10 years power off life cycle 3 2 2 Master Clock This product has a system clock PLL Phase Lock Loop which may be phase locked to the DS1 line clock or internal clock The default master is the DS1 line clock 27 Chapter 3 Operation NOTE If no DS1 line clock is available Loop AM will automatically switch to the internal clock source Loop AM will automatically switch back to the DS1 line clock when card plug in 3 2 3 Console Port The console port allows the user either to use a local VT 100 terminal via DB9 connector or use a remote VT 100 terminal via modem for system configuration diagnostics polling status reports etc The console port baud data bit length stop bit length parity bit length XON XOFF flow control and interf
104. SOR MOVE TAB ROLL OPTIONS Test Slot A EL Test Port Pattern Type 2exp20 1 Split Mode Send AIS Test Channel Mapped Test Direct To Line User Pattern 00000000 Period sec 0000000 Test Enable DISABLE lt lt Press ESC key to return to previous menu gt gt 93 Chapter 6 Terminal Operation 6 2 13 Alarm Cut Off Press A to show the alarm cut off screen gt gt Cut off alarm are you sure Y N 6 2 14 Clear Alarm Queue Press X to show the clear alarm queue screen gt gt Use TAB key to select unit and ENTER key to clear alarm ALL SLOTs 6 2 15 Controller Return to Default Press Y to show the return to default screen gt gt Return to default are you sure Y N 6 2 16 Controller Reset Press Z to show t he system reset screen gt gt Restart Mode Warm Restart Cold Restart gt gt SPACE bar to refresh or enter a command gt 6 2 DTE V 35 Sub Menu Under the Controller Menu press U to choose a slot for the DTE V 35 port Then the following Port Menu of DTE V 35 port will show SLOT 3 DTE PORT 1 Port Menu 10 40 07 07 06 2006 Version SW V2 01 02 04 27 2006 DISPLAY SETUP C DTE Configuration S gt System Setup DTE Status L Loopback Test H Alarm History M Alarm Setup G Upgrade Firmware LOG MISC Log Off O gt Log On B gt DTE board Return to Default U
105. T 3 DTE PORT Setup Configeration 18 35 35 03 01 2001 DTE Port 1 TEST MENU DTE Loopback OFF TO DTE TO DS1 Send V 54 Activate Code to Far End s DTE Send V 54 Deactivate Code to Far End DTE Send BERT OFF ON lt lt Press ESC key to return to previous menu gt gt SLOT 3 DTE PORT 1 Unit Loopback and Test 18 35 39 03 01 2001 ARROW EYS CURSOR MOVE ENTER KEY ITEM SELECT TAB NEXT PREV UNIT Note Pattern type of Bert is 2 15 1 98 Chapter 6 Terminal Operation 6 2 22 Alarm Setup To set up the alarm configuration press M The following screen is displayed SLOT 3 DTE PORT 1 Alarm Setup 18 35 43 03 01 2001 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Port Alarm Relay Unit 3 Js DISABLE DISABLE Unit 3 2 3 DISABLE DISABLE Unit 3 38 DISABLE DISABLE Unit 3 4 DISABLE DISABLE Unit 3 5 DISABLE DISABLE Unit 3 6 DISABLE DISABLE lt lt Press ESC key to return to previous menu or save setup gt gt 6 2 23 Upgrade Fireware To set up the alarm configuration press G The following screen is displayed LOOP AM3440 C Download Firmware 16 02 46 07 14 2006 ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn BACKSPACE to edit Bank 1 Firmware Ver V2 01 01 03 03 2006 Good Bank 2 Firmware Ver V2 01 01 03 03 2006 Good Working Firmware Bank 1 TFTP Server IP 1924163891 Firmware File Name hdsl f run lt lt
106. TE1 channel should be B1 B2 ERROR15 the DTE1 channel should be B1 ERROR16 the DTE1 channel should be B1 B2 ERROR17 Remote doesn t have this function ERROR18 Remote unit rejected this request ERROR19 Remote unit didn t respond ERROR20 Remote DTE1 TTM should be off ERROR 21 the DTE1 channel should be IDLE ERROR22 the DTE1 is not installed ERROR23 undefined response ERROR24 the unit didn t response ERROR25 speed can t be zero if MCLK DTEn ERROR26 the unit is not installed ERROR27 ESF or ESF amp T1 403 mode is required ERROR28 ESF amp T1 403 mode is required ERROR29 E1 CRC and FDL must set to be on ERROR30 LLB or LOCAL LOOPBACK activated ERROR31 EOC is not ready ERROR32 Current slot is not HDSL card ERROR33 Current slot is not DTE card ERROR34 Not enough channels ERROR35 Slot need to download firmware ERROR36 Time slot conflict ERROR37 Reserved for future use ERROR38 Reserved for future use ERROR39 Reserved for future use ERRORA40 Reserved for future use ERROR41 Reserved for future use 36 Chapter 4 Maintenance 4 Maintenance 4 1 Self Test When Loop AM is powered up a complete self test routine is run to check all I O ports read write memory and data paths to validate system integrity 4 2 Diagnostics Diagnostics for AM3440 covers Loopback and Test Pattern Generally the Loopback funcations might be very in different type of plug in cards Please go to individual plug in card manual for detail inf
107. The current selection will be highlighted by an asterisk SLOT D ATM FR El Port 1 Hour Perf Report 16 29 59 07 24 2002 USER Valid Seconds in Current 15 Min Interval 16 seconds ES UAS BES SES DM CSS Current 15 Min Interval s 16 0 0 0 16 list Nearest 15Min Interv at ESS Sen RSS Sores soos 2nd Nedrest L5b Mrin Interval i messes dm meg oes Sra Nearest 15 Min Interval esse Sere meo S mee m Ath Nearest L5 Main Interval 2 esse omer Seer OL SEE Valid 15 Min Intervals in Current 24 Hour Interval O0 ES UAS BES SES DM CSS Current 24 Hour Interval i ve Pett QE 07 23 2002 E MELLE NE 07 22 2002 MIL MM LL cht ee AD Meme oe 07 21 2002 DLS Roa SMe SSS Po M E 07 20 2002 ee ORR AGFS GASSED 07 19 2002 ME MEL LI ME a 07 18 2002 I SESA BARSE aM C SEE 07 17 2002 Res Abe Se SES lt lt TAB key to show Statistics Report gt gt lt lt ESC key to return to previous menu SPACE key to refresh gt gt 113 Chapter 6 Terminal Operation SLOT D ATM FR El Port 1 Hour Stat Report 16 30 04 07 24 2002 USER Valid Seconds in Current 15 Min Interval 16 seconds SAS SEFS SES SBES SSES CSS Current 15 Min 0 0000 0 00005 0 0000 0 0000 0 0000 0 0000 100 005 LVSt Nearest PISMEN SSSR E Uu SS SSS 2nd Nearest 15 Mim
108. U gt Choose Other Slot Z Card Reset P gt Choose DTE Port E Return to Main Menu Reset are you sure Y N 105 Chapter 6 Terminal Operation 6 4 DTE X 50 Sub Menu Under the Controller Menu press U to choose a slot for the DTE X 50 port Then the following screen will show SLOT 3 X50 PORT 1 Port Menu 17 48 57 07 10 2006 Version SW V2 01 01 06 28 2006 DISPLAY SETUP C DTE Configuration S gt System Setup DTE Status L Loopback Test H Alarm History M gt Alarm Setup G gt Upgrade Firmware LOG MISC Log Off O gt Log On B DTE board Return to Default U Choose Other Slot Z Unit Reset P gt Choose DTE Port E Return to Main Menu gt gt SPACE bar to refresh or enter a command gt 6 4 1 DTE Configuration Under the Port Menu press C to view the unit configuration the screen will show as below SLOT 3 X50 PORT 1 09 46 37 05 23 2001 Unit Configuration LOCAL Channel 72 X50 MUX NO MUX SYNC mode SYNC Rate 1 2K Phase fixed 4 8k sel fixed Clock Normal Data Normal RTS Permanent TTM Off Interface RS 232 lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 106 6 4 2 DTE Status Under the Port Menu press Chapter 6 Terminal Operation to view the unit status the screen will show as below BERT SLOT 3 X50 PORT 1
109. U B Traceable to SSU type B see G 812 Reserved Reserved Synchronous Equipment Timing Source SETS Reserved Reserved Reserved nIMOIOIm gt ol o Do not use for synchronization 92 Chapter 6 Terminal Operation 6 2 12 Bit Error Rate Test This menu is used to do bit error rate testing Press T from the Controller Menu Note that this function is not available for these cards Router ATM Frame Relay Dry Contact FXS FXO E amp M and Magneto For test channel when a channel is set as 1 which means this channel is used to do bit error rate testing There are two options are available full or mapped Note that only E1 and T1 cards support full channel When this option mapped is selected for test channel which means user should set up map first For split mode two options are available 1 Send AIS sending AIS to the other side or 2 OFF no sending AIS For Period if set to 0 means text is permanent Other value will stop the test after time out 2 15 1 215 1 ars Alarm Indication Signal ses Severely Error Second BER Bit Error Rate BER Bit Error Elapsed Second SES x test channel x 64 000 ESR Error Second Ratio ESR Error Second Elapsed Second SES sesr Severely Error Second Ratio SESR SES Elapsed Second AM3440 E1 Devices LOOP AM3440 C BERT Test 16 31 57 12 10 2008 ARROW KEYS CUR
110. VE Port Setup TAB ROLL OPTIONS 15 06 39 12 10 2008 lt lt Press ESC key to return to previous menu or save setup gt gt Note Configuration Rate Clock Data RTS TTM V 54 6 3 5 Loopback Test To setup the loopback test press L from the Port Menu The screen will show as below Option 64KBps 56KBps Normal Inverted Normal Inverted Permanent Active Off On Off On Default 64KBps Normal Normal Permanent Off Off 102 Chapter 6 Terminal Operation SLOT 1 DTE PORT 1 Unit Loopback and Test 15 42 13 12 10 2008 ARROW EYS CURSOR MOVE ENTER KEY ITEM SELECT TAB NEXT PREV UNIT DTE Port 1 TEST MENU DTE Loopback OFF TO DTE TO DS1 Send V 54 Activate Code to Far End DTE Send V 54 Deactivate Code to Far End DTE Send BERT OFF ON lt lt Press ESC key to return to previous menu gt gt Note Pattern type of Bert is 2 15 1 6 3 6 Alarm Setup To setup the alarm setup press M from the Port Menu The screen will show as below SLOT 1 DTE PORT 1 Alarm Setup 15 42 58 12 10 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Port Alarm Unit 1 12 DISABLE Unit 1 2 DISABLE Unit 32 DISABLE Unit 4 DISABLE Unit 1 CE DISABLE Unit 1 6 DISABLE Press ESC key to return to previous menu or save setup 103 Chapter 6 Terminal Operation 6 3 7 Upgrade Firmware To setup the upgrade fir
111. VVVN NM lt lt Press ESC key to return to Main Menu or enter a command gt gt 70 Chapter 6 Terminal Operation Then press C from the above Controller Setup menu to set system map The following two screens show map settings for the right side s example Target Source TSl v p Data Voice Below settings are for SlotA time slot TSI 01 mapping to SIotB time slot 01 and SIotA time slot 01 mapping to Slot1 Port1 time slot 01 AM3440 C LOOP AM3440 C System Setup SYSTEM 15 47 02 09 09 2011 Please nput decimal number 0 9 BACKSPACE to edit System Time Date 15 47 02 09 09 2011 Device Name LOOP AM3440 C Network NI EN IPAddress SubnetMask Frame LB Timer LAN ON 192 168 014 189 255 255 255 000 Ethernet WAN 0FF 010 010 012 002 255 255 255 000 HDLC 00000001 Gateway Interface LAN Gateway IPAddr 192 168 014 254 CONSOLE port Baud Rate 9600 Data Length 8 Bits Stop Bit b Bat Parity NONE XON XOFF XOFF TSI map Clock TSI Function 1 N Multicast Clock Mode Normal Idle Signalling 1010 lt lt Press ESC key to return to previous menu gt gt Below setting is for mapping Slot A s time slot 01 to Slot B s time slot 01 LOOP AM3440 C System Setup MAP 10 57 08 09 29 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO MAP 1 Target E1 NON CAS Source El NON CAS Target PO TS D SL PO TS PO TS D SL PO T
112. Vac 80W Power Module System Power Consumption Power Consumption Watt Power Consumption Watt Power Consumption Watt Controller Single controller 4 Mini Slot 1 channel E1 1 channel T1 Mini Quad E1 1 channel E1 ATM Frame Relay 1 channel T1 ATM Frame Relay 32 WAN port Router 64 WAN port Router A Fiber optical interface 3 channel Terminal Server Quad 2W AW E amp M QFXS QFXO 1 channel EIA530 1 channel RS232 1 channel V 35 I channel X 21 Single Slot 4 channel E1 4 channel T 1 6 channel U 10 channel U 2 channel G SHDSL 2 pairs w o line power 4 channel G SHDSL 1 pair w o line power 8 channel G 703 card at 64 Kbps data rate 8 channel Dry Contact I O 8 channel 2W 4W E amp M NI G2 DO OT ALVIN GO 9 POP DO OT S ND DO CO DO CO OINDININ 12 channel FXS oO 12 channel FXO 12 channel Magneto 1 channel low speed optical C37 94 4 channel low speed optical C37 94 8 channel RS232 with X 50 subrate 8 channel Data Bridge Card 8 LAN port 64 WAN port Router B 3 Channel E1 Conference Card TDMoE 1FOM A Dual Slot 6 channel X 21 V 11 6 channel V 35 6 channel V 36 6 channel EIA530 RS449 card 5 channel RS232 with X 50 subrate 24 channel FXS 24 channel FXO 2 channel G SHDSL 2 pairs with
113. ace type are as shown below Table 3 1 Console Port Setting Fixed Setting 9600 Data Bi fe 3 2 4 Menu Lock The terminal is used to read alarms system configurations and system status It also can be used to change system configurations and clear the alarm queue etc By enabling the menu lock only read operations are allowed Modifications to the current status are not allowed Users may not change system configurations or clear performance data Password menu clock options disabled by default The default password is LOOP 3 2 5 Logon Logoff and Password Logoff prevents system configuration changes at the terminal while logon allows system configuration changes The password feature is used to augment lock control against unauthorized terminal users from changing system parameters from the terminal With password enabled logon requires entering the correct password If password is disabled no password is required to logon The default option of the password is disabled The default password is LOOP If password is enabled users must enter the password when logging in to gain the privilege to change system configurations by the terminal To change the password for the first time enter the default password when prompted for the old password 28 Chapter 3 Operation 3 3 Alarms and Reports 3 3 1 Alarms Loop AM has many types of alarm This includes system to control all of alarm as list
114. ads 6 channel X21 V 11 3 channel E1 gt 6 channel V 35 4 channel E1 6 channel V 36 gt 4 channel T1 gt channel EIAS30 RS449 2 channel G SHDSL w o line power 5 channel RS232 with X 50 subrate gt 4 channel G SHDSL w o line power 24 channel FXS d i GST 24 channel FXO eee ps i 8 channel Dry Contact I O 8 channel Dry Contact I O type B 8 channel 2W 4W E amp M 12 channel FXS 12 channel FXO gt 12 channel Magneto 1 channel C37 94 4 channel C37 94 8 channel RS232 with X 50 subrate 8 LAN port 64 WAN port Router B gt Conference card TDMoE 8 Data Bridge 1FOMA Figure 1 1 AM3440 C Application Illustration 1 of 2 AM 3440 C Y BOX Chapter 1 Product Description Application TE T Bi card LoopView SNMP Manager LAN Mini Slot plug in Cards Figure 1 2 AM3440 C with Y BOX 2 of 2 2 1 channel E1 1 channel T1 Mini Quad E1 1 channel E1 ATM Frame Relay 1 channel T1 ATM Frame Relay 32 WAN port Router 64 WAN port Router Fiber Optical Interface 3 channel Terminal Server Quad 2 W 4W E amp M QFXS QFXO 1 channel DTE 1X 21 1V 35 1RS232 or 1EIA530 Note 1 Only CHCJ Unit applicable to DSO SNCP function E1 Line Chapter 1 Product Description 1 4 Specifications for AM3440 C
115. and CLP to constant 1 132 Chapter 6 Terminal Operation SLOT D ATM FR El Please Input index 4 1 10 Port Connection Table Setup 10 25 48 09 13 2002 CR DECI VET BACKSPACE to edit amp Translation DE C MA n OoOooooooocooooo 101 102 e OO Oo 0 0 lt 0 gt Network 0 0 lt 0 gt Network 0 0 0 Network 0 0 0 Network 100 64 64 Network 101 256 lt 0 Network 102 64 64 Network 0 0 lt 0 gt Network 0 0 lt 0 gt Network 0 0 0 Network 0 0 lt 0 gt Network 0 0 0 Network 0 0 0 Network lt lt Press ESC key to return to previous menu gt gt MA MA MA MA MA 0 MA MA MA MA MA MA MA LP p gU y F0 FO rg rg The entire connection table can be viewed by paging through the line numbers using the space bar Each of the line numbers line index can be edited The procedure is as follows 1 Move the cursor to the index number Type in the line number followed by ENTER 2 Edit any of the entry by moving the cursor to that entry For numbers enter the new number followed by ENTER For option choices use TAB key to cycle through the availabe choices 6 5 11 3 Setup Specific to FR FR Protocol In the following setup will be for the FR FR protocol From the E1 T1 menu select Frame Relay for th
116. ange to TSI Map LOOP AM3440 C System Setup New map 18 17 40 11 25 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Last activated TSI Map MAP 1 Change to TSI Map MAP 1 This item will be ignored if anyone of the following is enabled TSI Map switch start hr min Mapl DISABLE 00 00 Map2 DISABLE 00 00 Map3 DISABLE 00 00 Map4 DISABLE 00 00 lt lt Press ESC to return to previous menu gt gt Note when the TSI Map switch function has been selected The upper setting of Change to TSI Map will not function The TSI Map setting shows below is function by Time duration setting Sample below shows Map 1 enable from 00 00 to 11 59 and then it will switch to Map 2 from 12 00 to 23 59 The map3 and map 4 will not function due to disable TSI Map switch start hr min Mapl ENABLE 00 00 Map2 ENABLE 12 00 Map3 DISABLE 00 00 Map4 DISABLE 00 00 You can view the TSI Map setting from Controller Menu gt C System Configuration gt C Current TSI Map 6 2 7 6 Copy a TSI Map to another Controller Menu gt S System Setup gt E Copy a TSI Map to Another This funcation is to copy the TSI map from one to another LOOP AM3440 C System Setup Copy 19 01 17 11 25 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Copy TSI Map from MAP_1 to MAP 2 lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt 61 Chapter 6 Terminal Operation 6 2 7
117. ar No 6 d 22 d 6 d 22 d d v s 3d 7 d 23 d Frad 23 d 8 d 24 d 8 d 24 d 9 d 25 d 9 25b d Source 10 d 26 d 10 d 26 d Slot B Lela 27 d 11 d 27 d Port 12 d 28 d 12 d 28 d Tag 01 13 d Z9 d i3 d 29 d 14 d 30 d 14 d 30 d Confirm Yes TS d 3l 15 d Sir da 16 d 16 d lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt 126 Chapter 6 Terminal Operation 6 5 10 2 Map slot D ATM FR to slot 6 V 35 card LOOP AM3440 C System Setup MAP ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO MAP 1 Target ATM FR Source Target PO TS D SL PO TS PO TS D SL PO TS PO TS D Slot D DS a Se Port 1 d B 17 d 1 qi 05 2d B 2 18 2 d 3 B 3 l9 g d 4 d B 4 20 d 4 d T S 04 5 d 61 21 d 5 d Clear No 6 d 61 2 22 d 6 d d v d 7 d 61 3 23 7 d 8 d 61 4 24 d 8 d 9 dg 29 d 9 d Source 10 d 26 d 10 d Slot 3 Lis id 275 30 11 d Port P1 12 d 28 d 12 d T Ss 01 13 d 29 d 13 d 14 d 30 d 14 d Confirm Yes 1 5 d 31 d L5 d T5 d 16 d Press ESC to return to Controller Setup menu SL PO 10 08 40 RTR TS PO TS then Press D to active 09 13 2002 D SL PO TS 62 9 E OL Qn Qe cQ E E Dh OO 9 20 22 6 5 10 3 Map slot D ATM FR to slot 1 V 35 card LOOP AM3440 C System Setup MAP ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO MAP 1 Target ATM FR Source Target PO TS D SL PO TS PO TS D SL PO TS PO
118. ce INTERNAL Second Clk Source INTERNAL Current Clock MASTER CLK Recover Mode MANUAL Clock Status NORMAL Ext Clock Type PIS Dual External Clock Protection Disable Press ESC key to return to previous menu The clocks on the SLAVE units will be set up as shown in the screen below LOOP AM3440 C System Setup CLOCK SSM Mode 16 13 15 12 05 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS First Clock Source SLOT 1 Pl Second Clock Source SLOT 1 P2 Third Clock Source SLOT 1 P3 Current Clock INTERNAL Clock Status NORMAL Press ESC key to return to previous menu 5 FDL Facilities Data Link On the Port System Setup screen set the FDL must be set at SSM for all ports in the ring ie Slave unit ports and Master unit ports This setting is highlighted on the sample setup screen below SLOT A MQuad E1 PORT 1 Port System Setup 15 24 25 03 24 2006 171 Chapter 11 Appendix E Setting up an AM3440 C PDH Shared Protection Ring ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS FRAME ON CODE HDB3 CRC ON RAI ON AIS FRAMED CAS OFF SIGNALLING TRANS CGA NORM 005 BUSY Sa bit Sa4 IDLE 5 Protected DISABLE Master SLAVE INTF 120 Ohm Warning If you need to change FRAME and CAS Please clear TSI MAP MAP1 4 of this port lt lt Press ESC key to return to previous menu gt gt 6 TSI Function The TSI f
119. ck Protection Disable lt lt Press ESC key to return to previous menu gt gt 44 Chapter 6 Terminal Operation 6 2 1 3 TSI Map Controller Menu gt C System Configuration gt C TSI Map The TSI Map shows the map configuration status for all map slots and ports The sampe screen shows Map 1 Slot C Single E1 current map configuration status LOOP AM3440 C System Configuration Map 11 00 17 11 10 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Map Number MAP 1 Slot Number C El PO TS D SL PO TS PO TS D SL PO TS Port Number ld 7 le 17 77 17 2d 7 2 18 d 18 Sow CI 3 19 d 7 19 4 7 4 20d 7 20 7 D 2l uw 21 6d 7 6 22 qud 7 23 d 7 23 8d 7 8 24d 7 24 9 4 9 25 dd 27 25 10 a 7 10 26 d 7 26 itd 11 27 d 7 27 12 d 7 12 28 d 7 28 l3 x 7 13 29 d 7 29 14d 7 14 30d 7 30 l5 d y 15 73 3l 16d 7 16 lt lt Press ESC to return to previous menu gt gt 6 2 1 4 Current TSI Map Controller Menu gt C System Configuration gt D Current TSI Map The screen of Current TSI Map will show as below The sampe screen shows Slot B RTA current map configuration status LOOP AM3440 C System Configuration Current Map 11 00 57 11 10 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Current Map Slot Number B RTR A PO TS D SL PO TS PO TS D SL PO TS Port Number Pl 1d 17 d 2 d 18
120. connected before install uninstall telephone wires e Never install telephone wiring during a lightning storm e Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations e Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface e Use caution when installing or modifying telephone lines 2 1 Site Selection The following list indicates a site selection guideline User need to follow this guideline to select a proper installation site e Location of the Rack should be part of the central office equipment layout design Considerations should be given to entrance cable routing and 48 Vdc power e Theinstallation site should have 48 Vdc power An optional AC DC power converter can be used Use Only with Class 2 power source 48 Vdc 100 watts 2 2 Mechanical Installation AM3440 C can be installed as a desk top unit or mounted on a 19 inch or a 23 inch rack Mounting of the unit in a rack follows standard telephone rack mount practices Accessories to install on a 19 inch or 23 inch rack is provided As a desk top unit AM3440 C is stackable 2 3 Electrical Installation Central office 48 Vdc power is wired to terminal blocks in the front of the AM3440 C shown in Figure 2 1 Central office alarm system is wired to the Alarm Relay terminal blocks For connection to the CONSOLE button down button up connector for
121. d Transmitted Bytes 0 Bytes 0 Frames 0 Frames 0 Discards 0 Discards 0 Drops 0 Drops 0 Channel 1 PVC Number 1 Total lt lt ESC key to return to previous 1 menu SPACE key to refresh gt gt 118 Chapter 6 Terminal Operation 6 5 3 3 ATM Statistics SLOT D ATM FR El Port ATM Statistics 14239353 07 21 2002 Total Connections 3 Bad HEC 0 VPI VCI Rx Frames Tx Frames Congestion Bad CRC Bad Len 1 2 01 0 0 0 0 0 2 2 05 0 0 0 0 0 3 2 06 0 0 0 0 0 4 2 07 0 0 0 0 0 5 2 08 0 0 0 0 0 6 2 09 0 0 0 0 0 7 2 0 0 0 0 0 0 8 2 1 0 0 0 0 0 9 2 2 0 0 0 0 0 10 2 3 0 0 0 0 0 11 2 4 0 0 0 0 0 1 2 2 5 0 0 0 0 0 1 2 2 6 0 0 0 0 0 14 2 Jd 0 0 0 0 0 15 2 8 0 0 0 0 0 16 2 9 0 0 0 0 0 lt lt ESC key to return to previous menu SPACE key to refresh gt gt 6 5 4 Unit Configuration The interface setting displays the egress port type E1 or T1 The Protocol setting specifies the protocol on the line ATM or Frame Relay The Channel Map setting specifies the type of traffic 1 specifies layer 2 traffic and i is idle When the line carries ATM traffic this setting cannot be modified To view the port configuration press C from the port menu the screen will show as below 6 5 4 1 System Setup ATM FR T1 To view the port configuration press C from the port menu SLOT D ATM FR Port System Setup 17 35 29 03 23 2002 FRAME ESF Int
122. e Controller Setup menu press A to enter in the screen of System Setup as below This menu is allowed to set up configuration for system console port and TSI map Network system setup is used to do different interface LAN WAN IP setup You can enable LAN or WAN or both for point to point communication Setup prodedure is as follows If you would like to manage your AM3440 units through inband management go to System Setup MAPY to activate TSI map setup first The command path is Main Menu S Controller Setup gt C TSI Map Setup Choose for target slot then selet the card type and port you would like to use Then choose Yes to confirm your new settings LOOP AM3440 C System Setup MAP 10 41 53 09 29 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO MAP 1 Target In Band Source El NON CAS Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS Slot LB TRASTE SRE SSSSSSSSSS POTE 1 d 1 1 TF d T 2S vrl 2 d 18 d 3 8 19 d 4 d 20 0 Te Sigh 4 1 5 4 2 8 Clear No 6 d 22 d d v sca 7 d 23 d BU 24 d 9 d 25 d Source 10 d 26 d Slot 2 li d 23 d Port 12 d 28 d TS gt 501 13 29 d 14 d 30 6 Confirm Yes 15 d 31 16 d lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt 52 Chapter 6 Terminal Operation Go back to sysetm setup First enable your network by choosing ON
123. e Protocol Screen below illustrates that for the T1 interface 6 5 11 3 1 Port System Setup SLOT D ATM FR CURSOR MOVE ARROW EYS RAME ODE EL IS NBAND NTF BO DHHDK Q ESF B8ZS ON FRAMED OFF LONG HAUL 0 dB TAB Port System Setup ROLL OPTIONS Interface t EL Protocol Frame Relay Channel Map 111111111111111111111111 lt lt Press ESC key to return to previous menu gt gt 22 50 06 07 15 2002 133 Chapter 6 Terminal Operation SLOT D ATM FR El Port System Setup 10 16 36 09 13 2002 ARROW EYS CURSOR MOVE TAB ROLL OPTIONS FRAME ON Interface EL CODE HDB3 Protocol Frame Relay CRC ON Channel Map RAI ON ITI11111T1T111171I11111T71111111111 AIS FRAMED CAS OFF FDL OFF Sa bit Sa4 INTF 75 Ohm lt lt Press ESC key to return to previous menu gt gt 6 5 11 3 2 Channel Map Setup Select the CH MAP item on the Port System Setup menu Use this channel map to tell the ATM FR card what time slots are combined to be a logical frame relay channel FR channel The logical FR channel number can be 1 to 31 eg FR 1 to FR 31 A 0 will indicate an idle time slot SLOT D ATM FR El Port Channel Map Setup 10 17 28 09 13 2002 Please Input 1 10 BACKSPACE to edit Time Slot 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 FR Channel 01 01 01 00 00 00 00 00 00 00 00 00 00 00 00 00 Time
124. e other card For example Port 1 of the protection card protects Port 1 of the other card Similarly Port 2 of the protection card protects Port 2 of the other card etc To configure the QDS1 1 1 Protection function in the follow procedure 1 Select the QDS1 1 1 Protection function in Controller Menu S System Setup Q QDS1 1 1 Protection 2 Set TSI Map in Controller Menu gt S System Setup C TSI Map Setup Note You MUST set the protection first and then set the TSI map 9 2 Setting Up Circuit Protection 9 2 1 Connecting the Y Box to the AM 3440 C Shelf There are two Y Box types available for the AM 3440 One has BNC connectors and can handle up to 4 lines The other has RJ 48C connectors and can handle up to 16 lines For every four lines you wish to protect you must have one pair of Quad E1 cards or one pair of mini Quad E1 plug in cards in the AM3440 The following setup is using Quad E1 card for demonstration If you are using the BNC type Y BOX use BNC cables to connect it to the AM3440 C as shown in Figure 9 1 below For illustration purposes only Port 1 is protected in this sample diagram To protect other ports you must connect them in a similar manner 154 Chapter 9 Appendix C QDS1 1 1 Protection G CTRL2 Qe CTRL 1 Qe Mini Plug n C S Mini Plugin B p F Mini Plugin Qe Plug in 3 un B es oh Ee Plug i DIOIO OCH
125. ed in Tables below Also Loop AM has alarm queue which record the latest 200 alarms with time stamp Alarm queue support controller switched Loop AM also has alarm history and alarm status registers which is used to track the alarm count Each alarm can be individually enabled or disabled When disabled no action is taken When enabled alarm counter increments on the occurrence of the specific type of alarm When alarm occurs or the counter threshold exceeds alarm is triggered When alarm is triggered a relay is activated if itis enabled Otherwise no action is taken and only the specific alarm count is incremented When threshold level is implemented it is based on the 15 minutes alarm count register All alarms are disabled by default The relay is also disabled by default Table 3 2 Alarm Action Table Alarm Action Alarm Severity enable or disable all alarm event include card alarm Disable Enable enable or disable relay while alarm occurs Disable Manual Auto Alarm Cut Off issue alarm to Management if alarm cut off key Disable Enable pressed Table 3 3 System Alarm Type Table Alarm Type Alarm Description Alarm Severity Port Inactive alarm control for Disable major minor critical a slot inactive pull out card or card failed b redundant loss redundant CPU pull out or failed c redundant checksum error checksum error while transmit data from primary to redundant d redundant unsync redundant SW is not same wi
126. ent bor det bertskaffes via de sz rlige indsamlingssteder i landet Ved slutten av produktets levetid ber det avhendes kommunal milj stasjon eller leveres til en elektroforhandler L mna v nligen in produkten p l mplig tervinningsstation n r den r f rbrukad H vit tuote k yt i n p ttyess viem ll se asianmukaiseen ker yspisteeseen Gdy produkt nie nadaje sie juz do dalszego uzytku nalezy zostawic go w jednym ze specjalnych punkt w zajmujacych sie zbi rka zuzytych produckt w w wybranych miejscach na terenie kraju Po skon en jeho Zivotnosti odlo te pros m v robek na p islu n m sb rn m mist z zen m dle p edpis ve va zemi Po skon en jeho ivotnosti odovzdajte pros m zariadenie na pr slu nom zbernom mieste pod a platn ch miestnych predpisov a noriem Ko se izdelku izte e ivljenska doba ga odnesite na ustrezno zbirno mesto oziroma ga odvrzite v skladu z veljavnimi predpisi T Aog AEttovpyucns Zo tou ota si yopa AU SE FH Serm RR a CE PEI ER TRES EE F vi Chapter 1 Product Description 1 Product Description 1 1 Function Description For AM3440 Access DCS MUX The Loop AM3440 C series are Access DCS MUXS that combine various digital access interfaces
127. equency accuracy of system clock is lower than 198 ppm the system clock will track the reference clock 88 Chapter 6 Terminal Operation B For SSM Synchronous Status Message Clock Mode Under the Controller Setup menu press A to get in System Setup SYSTEM menu as below screen shows Use arrow keys to move the cursor at Clock Mode item and TAB key to choose SSM option Note that the SSM clock mode is only available for Quad E1 T1 mini Quad E1 FOM and 1FOMA cards LOOP AM3440 C System Setup SYSTEM 15 07 56 09 13 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS System Time Date 15 07 56 09 13 2011 Device Name LOOP AM3440 C Network NI EN IPAddress SubnetMask Frame LB Timer LAN ON 192 168 014 189 255 255 255 000 Ethernet WAN OFF 010 010 012 002 255 255 255 000 HDLC 00000001 Gateway Interface LAN Gateway IPAddr 192 168 014 254 CONSOLE port Baud Rate 9600 Data Length ScBits Stop Bit amp he Bart Parity NONE XON XOFF XOFF TSI map Clock TSI Function olr liBidirectiom Clock Mode t SSM dle Signalling 1010 lt lt Press ESC key to return to previous menu gt gt Press ESC key from the above screen Then press Y to confirm the new setting or N to abort LOOP AM3440 C System Setup SYSTEM 15 07 56 09 13 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS System Time Date 15 07 56 09 13 2011 Device Name LOOP AM3440 C Network
128. er with grounding and without grounding are shown below Note When the user uses DC power without grounding 77 noise problems and E1 errors may occur AM3440 C ER 0 2 p mee BIS Plug in 5 Plug in 4 2 Power Module Location Power Module Power Supply 1 48 Vdc gan He 2 48 Vdc 2 1 Hot 2 9 3 4 48Vdc amp X i zi g j N D Note QFXS QFXO 12FXS FXO 24FXS FXO 8EM 12 MAG can not use 48 Vdc 5 means short Figure 2 2 DC Power Without With Grounding Application Chapter 2 Installation For Dual CTRL protection NOTE When an AM3440 has two controller cards on applying power the left controller CTRL1 will always be the primary and the right controller CTRL 2 will always be the redundant If the redundant s configuration is different from the primary then after the controller boot up and initiation is completed the redundant CTRL will synchronize its configuration from the primary CTRL This synchronized takes 1 2 minutes During configuration synchronization the LED will show the following sequence 1 LED for primary CTRL power green active flashing green 2 LED for redundant CTRL power flashing green active dark Redundant CTRL will send heart beat every 0 5 second A
129. erface CODE B8ZS Protocol YEL ON Channel Map AIS FRAMED IIIITITIALdiLiT11 212121211 INBAND OFF INTF LONG HAUL LBO 0 dB lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 119 Chapter 6 6 5 4 2 System Setup ATM FR E1 To view the port configuration press C from the port menu Terminal Operation SLOT D ATM FR El FRAME ON CODE HDB3 CRC ON RAI ON AIS FRAMED CAS OFF FDL OFF Sa bit Sa4 INTF 120 Ohm Port System Setup 15 56 08 03 27 2002 Interface El Protocol Channel Map 111111111111111i111111111111111 lt lt Press ESC key to return to previous menu gt gt 6 5 5 Alarm History Press H from the port menu to view the alarm history 6 5 5 1 Alarm History FR to ATM LOT AI AIS LOS LOF BPV ES UAS CSS ATM ATM ATM ATM FR L S LOCAL R D LOS AIS RDI LOC KD ATM FR El ALARM TYPE THRESHOL 10E 5 lt lt ESC key to return to Port Alarm History D CURR STAT LM SABLE previous menu 17 24 14 07 21 2002 E COUNT ALAR 0 EN EN EN EN EN EN EN EN EN sh EN EN EN E Ed Ed Dd Ed DE Dd D Dd jS om uoooooooo gt D D UJ UJ UU UJ UJ CU tU UJ UU CO w UJ E J H UJ E SPACE key to refresh
130. erminal must be inserted to a designated time slot in the network This time slot can be a DSO channel in E1 or T1 line or a DSO channel any of the broadband facilities such as DS3 STM1 This can be achieved though a router CSU DSU mux series of equipment or in one step through a router interface on a Loop V 4200 LAN Loop V 4200 Loop AM 3440 C In Band Insertion In Band Extraction Management Terminal Next the equipment to be management namely this Loop AM 3440 C must extract this 64 Kbps time slot to the management port This is accomplished through the TSI screen Note Please refer to Appendix B Inband Management for detail 35 Chapter 3 Operation Table 3 9 Error Message Table The error messages defined here should be corresponded to the error codes Error Code Error Description ERRORO1 A loopback is in effect ERRORO2 LCD operation is locked ERRORO3 Channel is already in use ERRORO04 can t be in TTM if MCLK DTE ERRORO05 DTEn is in or speed is 0 ERRORO6 Line unsync ERRORO7 No channel is assigned ERRORO08 Please select speed first ERRORO09 A test is in progress ERROR10 DTE loopback is in progress ERROR11 Please reduce speed first ERROR12 Illegal Date Time format ERROR13 the DTE1 channel should be B2 ERROR14 the D
131. etup for setting LOOP AM3440 C System Setup Backup 15 14 36 08 18 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS motio Mum Mode Link Link A Link B Link C Link D Link 1 Link 2 Link 3 Link 4 Model FEL FE1 QuadT1 QuadEl QuadEl Backup Link Link B Link D HERDER Backup Fun OFF OFF OFF OFF OFF OFF OFF OFF Link Status Normal Normal Normal Normal Normal Normal Normal Normal Force Switch Link Link 5 Backup Fun OFF Link Status Normal Force Switch f protection type changed ex from 1 1 to 141 Please re setup map Field Setting Options Default Backup function ON OFF ON 1 1 ON 1 1 OFF Mode non revertible revertible non revertible Backup Link Choose the backup link N A 149 Chapter 7 Appendix A Link Backup Function Configure the TSI Map Command Path Main Menu gt S System Setup gt C TSI Map Setup Description This function is to do the TSI Map Setup Select the desired slot and port number for the mapping target Next select the starting timeslot number T S and the timeslot amount T S and data or voice d v for target Also select the desired slot port and starting timeslot number T S for the mapping source After configuration select Yes for confirmation Note More detail please see TSI Map Setup in Chapter 6
132. five nodes Note ULSR ring does not suport E1 unframe mode Users must use E1 frame mode to set up a ULSR ring E1 Port A Router 4E1 Management PC Inband Inband Mamnagement is set by Port B Port C assigning1 DSO 64K for inband management purposes on the TSI 4E1 TS1 31 4E1 timeslot map of each AM 3440 C unit Clk A Internal TS1 31 TS1 31 PS TS5 31 TS1 31 Cik A B 170 Chapter 11 Appendix E Setting up an AM3440 C PDH Shared Protection Ring 11 2 Setup Instructions 1 Nodes Set up four nodes each of which consists of a Loop AM3440 C device equipped with four Quad E1 cards or alternatively four Mini quad E1 cards or four E1 Fiber Optical Module Each of these nodes will be referred to as Slaves 2 Master Unit Set up a Master unit which consists of a Loop AM3440 C device equipped with three Quad E1 cards or alternatively three Mini quad E1 cards or three E1 FOM Fiber Optical Module cards and a single Router card 3 100 Each AM3440 C can be set up individually using a VT 100 monitor 4 Clocks The clocks must be set up on each of the AM 3440 C units If you have no SSM source at the MASTER unit set the clock for this unit at NORMAL SLAVE units must have their clock set at SSM LOOP AM3440 C System Setup CLOCK Normal Mode 15 22 10 12 05 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Master Clk Sour
133. from the above screen the following screen will show up SLOT A MQuad El PORT 2 Port 1 Hour Perf Report 10 22 19 10 27 2004 LINE Valid Seconds in Current 15 Min Interval 754 seconds ES UAS BES SES DM CSS Current 15 Min Interval 4 0 4 0 1 1 lst Nearest 15 Mrn Interval Fesses SSeS 2nd Nearest 15 Lnterval sae see ERROS compo 3rd Nearest 15 Min Interval s esses oye Sessa passes 4th Nearest 15 Min Interval Hesse ose eee Soren mess Valid 15 Min Intervals in Current 24 Hour Interval O0 ES UAS BES SES DM CSS Current 24 Hour Interval enr Les OMR Eee N S NE RSR ES 0 26 2004 0 25 2004 2 2 0 24 2004 2 2 0 23 2004 2 2 0 22 2004 I M MELLE MEL E eim 0 21 2004 2 0 20 2004 DM MEME CELL ML tee lt lt TAB key to show Statistics Report gt gt lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 139 Chapter 6 Terminal Operation Press TAB key to display the 1 hour statistics report as belwo shows SLOT A MQuad El PORT 2 Port 1 Hour Stat Report 10 22 48 10 27 2004 LINE Valid Seconds in Current 15 Min Interval 754 seconds AS SEFS SES SBES SSES
134. fter 5 consecutive no response from primary CTRL meaning primary CTRL dead redundant CTRL will take over AM3440 and become primary Primary warm restart reset will not switch control back to the left CTRL while Primary cold restart will switch Switching time is less than 50ms Condition To avoid sync failure the firmware version of CTRL1 and CTRL2 should be the same Plug in 3 Plug in 2 ello Plug in 5 2 2 Plug in 1 ollo Plug in 4 Main Access DCS Mux Shelf Front Side 5 Main Access DCS Mux Shelf Rear Side L 8 N 0096 0000 NI o 5 00000 J 310SNO2 c J SOVAH31NI G91 2 000000000000 loooooooooooo NN Figure 2 3 Panel Views Main Shelf and CPU Chapter 2 Installation Table 2 1 Power Connector for Main Unit DC 48 Volts DC Retur Chassis Ground The console port is configured as a DCE device with a DB 9 female connector Pin definitions and pin connections are listed in below Table 2 2 Console Port 4 Unassigned 5 SgnlGowmd o 6 DaaSetReajy __ ToDTE 0 7 Umsiged 8 Clartosnd 9 Unassigned _ Ethernet port can be connected via Ethernet 10 Base T interface Pin definition is listed in below Table 2 3 Ethernet Port TPTX TP Driver Output TPTX TPRX TP Receive Input 6 Chapter 2 Installation 2 3 3 Alarm Relay The Alarm Re
135. g Support up to 128 DLCIs for total of 31 FR interfaces Support up to 128 VCs Peak cell rate on DLCI basis Manufacturing disable enable ATM scrambling for internal testing E1 ATM only AALO and AALS are supported in the ATM adaptation layer Support VBR service ANSI and ITU FR management protocols are supported Flash memory software download through RS485 Only the PVC type of ATM FR service is supported n x 64 Kbps n 1 to 24 n x 64 Kbps n 1 to 31 Router Interface Number of ports Physical Interface 2 LAN ports Max 32 WAN ports 10 BaseT x 1 10 100 BaseT x 1 Connector RJ45 Routing protocol RIP I RIP II Data Rates Channelized N x 64 Kbps 1x n x32 DSX1w 0 7 5 15 dB LBO DA ESF selectable RJ48C ITU G 704 BNC RJ48C 75 ohm Coax 120 ohm twisted pair ITU G 823 ITU G 704 DB25S 75 ohm Coax 120 ohm twisted pair ITU G 823 ITU G 704 BNC RJ48C 75 ohm Coax 120 ohm twisted pair ITU G 823 ITU G 704 BNC RJ48C 75 ohm Coax 120 ohm twisted pair ITU G 823 DSX1w 0 7 5 15 dB LBO D4 ESF selectable RJ48C Supporting Protocols Router A Interface Number of ports Physical Interface Connector Routing protocol Supporting Protocols Diagnostic QoS Router B Interface Number of ports Physical Interface Connector Routing protocol Supporting Protocols Diagnostic QoS Chapter 1 Product Description TCP IP PPP HDLC 2 LAN ports Max 64 WAN ports Each WAN port has data rate n x 64K
136. ged unplugged unplugged 49 Chapter 6 Terminal Operation 6 2 5 Redundant Board Information Controller Menu gt R Redundant CTRL Information This function displays the redundant CTRL info the serial number hardware and software version of the redundant CPU Serial Number 8822 Hardware Version Ver F Software Version V7 05 02 12 03 2008 LOOP AM3440 C Redundant Board Information lt lt ESC key to return to previous menu 16 58 16 12 15 2008 SPACE bar to refresh gt gt If there is no reduncant CTRL card press R will show Reduncant Board does not exist Slot AD l5 Serial Number 125618 Hardware Version Ver H Software Version V8 17 03 07 20 2011 DISPLAY System Configuration Clock source Configuration Alarm Queue Summary gt Information Summary gt Redundant CTRL Information Performance Report LOG U gt Choose a Slot F Log Off SETUP MISC Menu O gt Log On SETUP MISC Menu LOOP AM3440 C Controller Menu 15 28 55 09 09 2011 Redundant Controller Disabled Start Time 15 11 27 09 09 2011 Device Name LOOP AM3440 C SETUP S System Setup M System Alarm Setup W gt Firmware Transfer V Store Retrieve Configuration K gt Clock source Setup T gt Bit Error Rate Test MISC A Alarm Cut Off X Clear Alarm Queue Y Controller Return to Default 2
137. gt 6 5 11 System Setup 6 5 11 1 ATM FR Card Configuration From the main system menu press U to select the PORT in this case PORT D Then from the PORT menu press S for Unit System Setup The following screen is shown At the bottom four setup choices are given For initial setup each of these four setup screens should be filled in An asterisk will highlight the current selection Use arrow keys to change selection Press ENTER to activate SLOT D ATM FR El Port System Setup l7 235 29 0372372002 gt gt Select ATM setup Tvpe 7 T1 E1 CH MAP FR MAN CONN TAB When the setup choice T1 E1 is entered The following screen is shown The Interface setting displays the egress port type E1 or T1 The Protocol setting allows the user to specify the protocol on the line ATM or Frame Relay The Channel Map with 31 time slot positions specifies the type of traffic A 1 specifies presence of layer 2 traffic in that time slot and an i indicates an idle time slot For ATM traffic this setting cannot be modified All of the E1 line settings Frame Code CRC and others must match that of the ATM network settings NOTE Although the following illustrations are for the E1 interface the procedure for the T1 interface are similar except for the 24 available time slots for T1 compared to 30 for E1 128 Chapter 6 Terminal Operation 6 5 11 2 System Specific to ATM Protocol In
138. gt 46dB 21 to 10 dB 0 1dB step transmit amp receive gt 25dB with 1004 Hz OdBm input 0 25 to 1 dB from 300 to 3400 Hz coincide with ITU T G 712 Max 65 dBmOp 16 Vrms L1 and L2 Tip and Ring L1 and GND Tip and GND Voltage 76 Vrms sine wave Frequency 20Hz with optional choices of 16 25 50 Hz Cadence 1 Normal Ring after crank 2 PLAR ON Single Ring Type ring for 2 sec and stop or ring for 4 sec and stop Continuous Ring Type 1 sec on 2 sec off or 2 sec on 4 sec off L1 and L2 Tip and Ring L1 and GND Tip and GND Magneto MRD Ringing across Tip and Ring or Tip and Ground Programable Signaling is carried transparently by the digitizing process Use Magneto card default setting for communications between magneto telephones Use Magneto card PLAR mode setting for communications between a magneto telephone and a regular telephone Conference Card Chapter 1 Product Description RS232 Interface Data Port ASYNC Data Rate SYNC Connector FXS Voice Interface Connector Encoding Longitudinal Conversion Loss Cross Talk Measure Gain Adjustment Signal Distortion Idle Channel Noise Loop Resistance FXS Loop Feed FXS Ringing Signaling E amp M Voice Interface Connector Encoding Impedance Longitudinal Conversion Loss Gain Adjustment Signal Distortion Idle Channel Noise Carrier Connection Phone line power 12V Operation mode Wire Mode Signaling Type EM Ringing
139. he Port Menu The screen will show as below LOOP AM3440 C Download Firmware 10 39 28 07 06 2006 ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn BACKSPACE to edit Bank 1 Firmware Ver V2 01 02 04 27 2006 Good Bank 2 Firmware Ver V2 01 02 04 27 2006 Good Working Firmware Bank 2 TFTP Server IP 010 003 005 001 Firmware File Name lt lt Press ESC key to return to previous menu gt gt 109 Chapter 6 Terminal Operation 6 4 8 Clear Current Port Performance Data To clear current port performance data press X SLOT 3 X50 PORT 1 Port Menu 09 46 30 05 23 2001 gt gt Clear Performance Data Y N 6 4 9 Return to Default Press Y to return to default SLOT 3 X50 PORT 1 Port Menu 09 46 30 05 23 2001 gt gt Return to default are you sure Y N 6 4 10 Reset Current DTE Board To reset DTE board press Z SLOT 3 X50 PORT 1 Port Menu 09 46 30 05 23 2001 gt gt Reset Board 9 Y N 110 Chapter 6 Terminal Operation 6 5 ATM Frame Relay Sub Menu Under the Controller Menu press U to choose a slot for the ATM FR port Then the following screen will show SLOT D ATM FR El Port Menu 09 41 53 09 13 2002 Version SW V3 03 01 03 2002 DISPLAY SETUP 1 gt Unit 1 Hour Perf Report L Unit Loopback Setup 2 Unit 24 Hour Perf Report M Unit Alarm Setup A gt Unit S
140. hernet WAN OFF 000 000 000 000 000 000 000 000 HDLC 00000001 Gateway Interface LAN Gateway IPAddr 000 000 000 000 CONSOLE port Baud Rate 38400 Data Length toB Bits Stop Bit Parity NONE XON XOFF XOFF TSI map Clock TSI Function 1 1 Clock Mode Normal Idle Signalling 1010 lt lt Press ESC key to return to previous menu gt gt Press ESC key from the above screen Then press Y to confirm the new setting or N to abort LOOP AM3440 C System Setup SYSTEM 12 14 18 12 05 2008 ARROW KEYS CURSOR MOVE Please Input hh mm ss mm dd yyyy BACKSPACE to edit System Time Date eo 12 12 18 12 05 2008 Device Name LOOP AM3440 C Network NI EN IPAddress SubnetMask Frame LB Timer LAN OFF 000 000 000 000 000 000 000 000 Ethernet WAN OFF 000 000 000 000 000 000 000 000 HDLC 00000001 Gateway Interface LAN Gateway IPAddr 000 000 000 000 CONSOLE port Baud Rate 38400 Data Length amp c8 CBXYts Stop Bit l Bit Parity NONE XON_XOFF XOFF TSI map Clock TSI Function l 1 Bidirection Clock Mode Normal Idle Signalling 1010 gt gt Change configuration Y N Note to save please use V command 87 Chapter 6 Terminal Operation Under the Controller Menu press K to do clock source setup Then the following screen will show up LOOP AM3440 C System Setup CLOCK Normal Mode 15 22 10 12 05 2008 AR
141. his is a sample TSI map for the Master unit Note that this map sets up the HDLC Inband Management mapping LOOP AM3440 C System Setup MAP 15 14 17 12 12 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO MAP 1 Target In Band Source DTE A Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS Slot 1 ld ld 4 3 17d 4 3 17 TuS op 01 2d 4 3 2 18d 4 3 18 4 de 3 19 d 4 3 19 4d 4 3 4 20d 4 3 20 T S 4 101 5d 4 3 5 21d 4 321 Clear No 6d 4 3 6 22 54 4 3 22 d v d 7d 4 3 7 23d 4 3 23 8d 4 3 8 24d 4 3 24 9d 4 3 9 25 d 4 3 25 Source l0d 4 3 10 26d 4 3 26 Slot 1 11 d 4 2211 27 4 3 27 Port Pl o4 o 12 28d 4 3 28 Teos See 13d 4 3 13 29 d 4 3 29 14d 4 3 14 30d 4 3 30 Confirm Yes 15d 4 3 15 31 d 4 3 31 16 d 32 d lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt 180 Chapter 12 Appendix F Setting up an AM3440 C PDH Shared Protection Ring T1 8 Ring Enabling From the Master Unit AM 3440 B Controller Setup screen press R to set up PDH Ring Protection LOOP AM3440 C Controller Setup 15 48 03 03 24 2008 System SNMP Setup Password TSI Map Setup Select a New TSI Map Copy a TSI Map to Another Clear a TSI Map Command Line Init New Card Clear Empty Slot
142. htur dte rts 334 gshdsl htuc dte extclk 335 gshdsl htur dte extclk 336 gshdsl dying gasp alarm 337 gshdsl loop attenu alarm 338 gshdsl low noise margin 339 gshdsl htur link down 340 12 FOM Card 1FOM A Card Number fom opt local lof 601 fom opt local los 602 fom opt local rai 603 fom opt remote lof 604 fom opt remote los 605 fom opt local es 606 fom opt local ses 607 fom opt local uas 608 fom e1 local lof 617 fom e1 remote lof 618 fom e1 local es 619 fom e1 local ses 620 166 Alarm type LOS MASTER LOOP1 LOS MASTER LOOP2 LOS SLAVE LOOP1 LOS SLAVE LOOP2 LOS LOF MASTER E1 LOS LOF SLAVE E1 ES15M MASTER LOOP1 ES15M MASTER LOOP2 ES15M SLAVE LOOP1 ES15M SLAVE LOOP2 ES15M MASTER E1 ES15M SLAVE E1 SES15M MASTER LOOP1 SES15M MASTER LOOP2 SES15M SLAVE LOOP1 SES15M SLAVE LOOP2 SES15M MASTER E1 SES15M SLAVE E1 ES24H MASTER LOOP1 ES24H MASTER LOOP2 ES24H SLAVE LOOP1 ES24H SLAVE LOOP2 ES24H MASTER E1 ES24H SLAVE E1 SES24H MASTER LOOP1 SES24H MASTER LOOP2 SES24H SLAVE LOOP1 SES24H SLAVE LOOP2 SES24H MASTER E1 SES24H SLAVE E1 SEALING CURRENT MCLK LOSS RTS MASTER DTE RTS SLAVE DTE EXTCLK MASTER DTE EXTCLK SLAVE DTE DYING GASP ALARM LOOP ATTENU ALARM LOW NOISE MARGIN HTUR LINK DOWN Alarm type LOF LOCAL OPTICAL LOS LOCAL OPTICAL RAI LOCAL OPTICAL LOF REMOTE OPTICAL LOS REMOTE OPTICAL ES LOCAL OPTICAL SES LOCAL OPTICAL UAS LOCAL OPTICAL LOF LOCAL E1 LOF REMOTE E1 ES LOCAL E1
143. ie 3 2 1 Board_Slot 0 Press ACO key to load default configuration 3 2 1 26 Chapter 3 Operation 3 1 3 Using Front Panel There is no front panel on the Loop AM3440 C A hand held LCD device which will take the place of a front panel is currently under development This device will allow configuration of and access to the various features without the need of a VT100 terminal Note Order separately for the hand held LCD device 3 1 3 1 Review of Default Settings All the default settings can be reviewed or changed This is done by selecting the menu item Either a sub menu is shown or the selected setting is indicated with an asterisk 3 1 3 2 Map Setup Connect a VT100 terminal to the Console port Press o to logon then press s for system setup Move the cursor to MAP and press Enter To change the settings use arrow keys to select time slot Press lt Tab gt to change the port values and enter numbers for the time slot Press lt Esc gt to exit the TSI map 3 1 3 3 DS1 Next adjust the DS1 settings 3 1 3 4 Unit Selection To review or change Slot settings press U Choose a Slot from the main menu 3 1 4 Using Terminal To use the RS232 interface to configure the unit connect a VT 100 terminal to the CONSOLE button down button up connector using a null modem cable The VT 100 terminal can be a PC running a VT 100 emulator software Upon connection press ENTER and E
144. ific AM3400 unit If you would like to make a series of AM3400 units to communicate though WAN network proceed to step 2 2 Once you start mananging a AM3440 unit go to System Setup MAP in VT100 and set up inband managemet Also choose a desired plug in card E1 or FOM for WAN network communication Then enable the WAN network and key in the IP address in System Setup Follow the same procedure to set up the units you wish to manage thourgh WAN network 3 AM3440 units will start communicating through E1 or FOM card under WAN network 53 Chapter 6 Terminal Operation 6 2 7 2 SNMP Controller Menu gt S System Setup gt S SNMP Setup The SNMP setup has 6 sub menu LOOP AM3440 C SNMP Setup 15 49 20 09 09 2011 A gt SNMP System Setup B V1 Trap Setup C gt V3 User Based Security Model Setup D gt V3 View Based Access Control Model Setup 1 E V3 View Based Access Control Model Setup 2 F V3 Target amp Notify Setup lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 6 2 7 2 1 SNMP System Setup Controller Menu S System Setup S SNMP Setup A SNMP System Setup The user must select SNMP model for V1 only V3 only or V1 V3 from the screen The user can reset the device name system location and system contact info LOOP AM3440 C SYetem Setup SNMP 18 07 39 11 25 2008 ARROW KEYS CURSOR MOVE BACKSPACE to edit ESC to abort
145. into E1 or T1 lines for convenient transport and switching The Loop AM3440 Access DCS MUX provides access for a variety of TDM IP and voice interfaces detailed on next page These interfaces are compatible with other Loop products Using these products a DTE interface can be extended over copper wire pairs or any E1 T1 transport facility For each Quad E1 T1 plug in card each card can have as many as DSO 124 96 time slots from G SHDSL RS232 X 21 V 35 V 36 and EIA530 RS449 interfaces which can be multiplexed to fill 4 E1 T1 lines AM3440 also supports fiber optical plug in card which can be used to aggregate up to 4 E1 channels onto a single fiber optical interface to connect with other AM3440 or O9310 E1 AM3440 C has capacity for 5 single slots and 4 mini plug in slots This unit is a full cross connect and can act as a mini DACS This means that one or more of the WAN ports can be used as a Drop amp Insert function with fractional E1 T1 lines which can be muxed into a full E1 T1 line Redundancy is available in dual CPU controller and power supply options making it an excellent fit for critical applications The Loop AM3440 C supports local control and diagnostics by using an external 2 line by 40 character LCD display and keypads or by using a VT 100 terminal connected to the console port The Loop AM3440 C also supports Ethernet Telnet and SNMP so that it can be controlled and diagnosed from remote locations as well An in band ma
146. ion that sends the alarm trap Note that the selection should be the same with the network interface NI that shows ON on the System Setup System screen If LAN is ON and WAN is OFF choose LAN for system trap IP If WAN is ON and LAN is OFF choose WAN for trap IP On the sample screen below both LAN and WAN are turned on In this case select either LAN or WAN for trap system IP according to your need LOOP AM3440 C System Setup SYSTEM 09 39 08 08 18 2010 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS System Time Date 09 39 08 08 18 2010 Device Name LOOP AM3440 C Network NI EN IPAddress SubnetMask Frame LB Timer 010 003 023 010 255 255 000 000 Ethernet 020 001 001 002 255 255 000 000 HDLC 00000001 Gateway Interface LAN Gateway IPAddr 000 000 000 000 Inband Uses Slot D or 12 Note Slot D or 12 port 4 can t use unframe mode 3 Select the Alarm Trap Type to decide the format of alarm type displayed in SNMP menu The alarm type tables for Vendor Spec and Assigned are listed in Appendix D cc Alarm Type 55 Chapter 6 Terminal Operation 4 Go to System Setup command path Main Menu S Controller Setup A System set up the nework interface type LAN and WAN and key in the IP address LOOP AM3440 C System Setup SYSTEM 09 39 08 08 18 2010 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS System Time Date 09 39 08 08 18 2010
147. ions for Loop VV Y BOX LINE Connector BNC or RJ48C Port Number For Y BOX with BNC connectors 4 line ports For Y BOX with RJ48C connectors 16 line ports Protection For Y BOX with BNC connectors support 2 Quad E1 plug in card 4 active E1 4 standby E1 For Y BOX with RJ48C connectors support 8 Quad E1 plug in cards 16 active E1 16 standby E1 For Y BOX with RJ48C connectors support 8 Quad T1 plug in cards 16 active T1 16 standby T1 Mechanical Height 44 5 mm 1 75 in Width 432 mm 17 in Depth 100 mm 3 9 in Future Option Front Panel View with BNC connectors N A 12 Chapter 2 Installation 2 Installation CAUTION e Only qualified service personnel shall install and maintain the system e This equipment must be connected to an earth socket outlet which has a permanent connection to protective earth with a cross sectional area of not less than 2 5 mm e Ensure protective earthing
148. isters These are line user and far end The line performance register tracks the DS1 line receiver performance status The user performance register tracks the DS1 line receiver as well but user may clear at any time The far end performance register tracks the far end DS1 receiver status The performance parameters are listed in below User performance register have an additional parameter CSS controlled slip second Each performance parameter has ninety six sets of registers to record 24 hours history in 15 minute intervals Table 3 6 Performance Parameter List Performance Description Definition Definition Parameter 2 Frame Multiframe 16 Frame Multiframe ES Error Second gt 1 gt 1 or CRC6 ERROR 2 1 CS gt 1 gt 1 or CS gt 1 BES Bursty Error 1 lt BPV lt 2048 1 lt CRC6 lt 860 Second SES Severe Error gt 2048 or OOF gt CRC6 gt 860 or OOF gt 1 Second 1 Degraded Minute BPV gt 123 CRC6 gt 47 LOFC Loss Of Frame OOF for 2 5 0 5 sec OOF for 2 5 0 5 sec Count UAS Unavailable 2 10 consecutive SES 2 10 consecutive SES Second CSS Controlled Slip frame slip gt 1 frame slip gt 1 Second Table 3 7 Performance Report Options Report Type Category Report ___ Report Menu Command ES UAS BES SES CSS LOFC Front Panel Reports USER Network 1 Hour Terminal USER Network LINE Network FAR END USER Network LINE Network USER Network
149. it Sabit must be F LOOP AM3440 C First Clock Source SLOT 1 P3 Second Clock Source SLOT 1 P1 Third Clock Source INTERNAL Current Clock FIRST CLK Clock Status NORMAL Internal Clock SSM Message 0 External Clock SSM Message 0 Frame Pulse Period 8001 2 Hz1 750ohm Clock Hold Over OFF lt lt ESC key to return to previous menu Clock Source Setup SSM Mode 11 09 22 10 04 2011 Tx Sabit Tx Sabit 4 Rx 4 Rx Sabit 1 SPACE bar to refresh gt gt The Unit 2 setting screen shown below SLOT 1 P1 is the current clock and top priority for the quality level of its receive Sabit is 4 So the quality level of its transmit Sabit must be F LOOP AM3440 C First Clock Source SLOT 1 Pl Second Clock Source INTERNAL Third Clock Source NONE Current Clock FIRST CLK Clock Status NORMAL nternal Clock SSM Message 0 External Clock SSM Message 0 Frame Pulse Period 8001 2 Hz1 750ohm Clock Hold Over OFF lt lt ESC key to return to previous menu Clock Source Setup SSM Mode 11 12 36 10 04 2011 Tx Sabit F Rx Sabit 4 SPACE bar to refresh gt gt 91 Chapter 6 Terminal Operation SSM code for E1 Operation Quality Level Description Quality unknown existing sync network Reserved Rec G 811 Traceable to PRS Reserved SSU A Traceable to SSU type A see G 812 Reserved Reserved Reserved SS
150. its must have their clock set at SSM LOOP AM3440 C System Setup CLOCK Normal Mode 15 07 24 12 12 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Master Clk Source INTERNAL Second Clk Source INTERNAL Current Clock MASTER CLK Clk Recover Mode MANUAL Clock Status NORMAL Ext Clock Type 5 Tl Dual External Clock Protection Disable lt lt Press ESC key to return to previous menu gt gt The clocks on the SLAVE units will be set up as shown in the screen below LOOP AM3440 C System Setup CLOCK SSM Mode 15 08 14 12 12 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS First Clock Source SLOT 1 P1 Second Clock Source SLOT 1 P2 Third Clock Source NONE Current Clock INTERNAL Clock Status NORMAL lt lt Press ESC key to return to previous menu gt gt 177 Chapter 12 Appendix F Setting up an AM3440 C PDH Shared Protection Ring T1 5 FDL Facilities Data Link On the Port System Setup screen set the FDL must be set at FDL and FRAME must be ESF amp T1 403 for all ports in the ring ie Slave unit ports and Master unit ports This setting is highlighted on the sample setup screen below SLOT 5 Quad Tl PORT 1 Port System Setup 10 35 03 03 06 2007 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS FRAME ESF amp T1 403 CODE B8ZS YEL ON AIS FRAMED CAS OFF SIGNALLI TRANS CGA NORM OOS BUSY INBAND OFF IDLE FF INTF LONG HAUL
151. k Number 1 lt lt Press ESC key to return to previous menu gt gt 77 Chapter 6 Terminal Operation 6 2 9 3 Download Configuration LOOP AM3440 C Download Configuration ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn TFTP Server IP 000 000 000 000 Config File Name lt lt Press ESC key to return to previous menu gt gt 19 10 51 12 04 2008 BACKSPACE to edit 6 2 9 4 Upload Configuration LOOP AM3440 C Upload Configuration ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn TFTP Server IP 000 000 000 000 Config File Name lt lt Press ESC key to return to previous menu gt gt 19 13 45 12 04 2008 BACKSPACE to edit 78 Chapter 6 Terminal Operation 6 2 9 5 Download Mainboard Boot up LOOP AM3440 C Download Bootup Code ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn Current boot up version V5 01 01 11 22 2007 TFTP Server IP 000 000 000 000 Download File Name lt lt Press ESC key to return to previous menu gt gt 11 16 44 12 05 2008 BACKSPACE to edit 6 2 9 6 Copy Firmware to Redundant LOOP AM3440 C Copy Firmware to Redundant Board ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn TFTP Server IP 000 000 000 000 Config File Name lt lt Press ESC key to return to previous menu gt gt 16 25 31 12 10 2008 BACKSPACE to edit 79 Chapter 6 Terminal Operatio
152. larm 9 Card type mismatch Link ID mismatch Primary start EH Redundant loss Dual CPU Alarm Redundant checksum error 8 Redundant insert Redundant unsync Redundant to primary Log in out Management Alarm for alarm action ENABLE for alarm action EN NEW only for firmware version V8 06 01 and up Model 32 controller for all CTRL alarm Plase refer to 10 2 Alarm Model for model type Slot N A D 1 12 O none 99 external R 103 ctrl1 external 104 ctrl2 external Port M 1 12 254 none Note An Cn Cn will clear alarm relay for An 169 Chapter 11 Appendix E Setting up an AM3440 C PDH Shared Protection Ring 11 Appendix E Setting up an AM3440 C PDH Shared Protection Ring 11 1 Overview A PDH Shared Protection Ring can be an ideal solution for voice and data transmission networks in that if any one E1 connection is broken the voice and data communication system will still function This protection is made possible by mapping a loopback to where the channel came from In a PDH Shared Protection Ring each line is split in two directions The working line outside line in the diagram below travels in a counter clockwise direction The protection line inside line travels in a clockwise direction While the is no theoretical limit to the number of nodes in a ring each node needs 2 3 seconds to stabilize SSM clock switching after a break occurs In our sample diagram below we have used
153. lay is applied to configure the Alarm Relay output present on the front panel of AM3440 Controller Card Alarm Relay outputs are provided for operators to drive external alerting devices such as flashing lights and sirens The Alarm Relay signals when the device has exceeded its alarm severity The Alarm Relay will act on pre set conditions configured by the user according to the tables below When the alarm setup is Enable the alarm relay circuit will be triggered if the alarm is detected To return the alarm relay to the normal state after it is enabled the user has three modes to choose from Auto Period and Manual For detailed information please refer to the section System Alarm Setup in the chapter of System Setup When the alarm setup is Disable the alarm relay circuit will stay in the normal state Activated alarm relay can be deactivated by pushing the ACO Alarm Cut Off button Table 2 4 Alarm Relay Circuit Contact State When Alarm Setup is Enable Circuit NC COM NO COM Condition System Power Off Open Alarm On Short Normal State for Auto Period and Open Manual Mode Alarm Cut Off or No Alarm Table 2 5 Alarm Relay Circuit Contact State When Alarm Setup is Disable Circuit NC COM NO COM System Power Off System Power On Alarm On Note The maximum voltage for the alarm relay is 3Vdc and the maximum currnet is 1A 2 3 4 Fuse Relay The fuse relay will be
154. lear a TSI Map Command Line nit New Card Clear Empty Slot Link Backup Function QDS1 1 1 Protection DSO SNCP Setup PDH Ring Protection PDH Ring Diagnostic SNTP Setup TELNET SSH Setup Power Setup b s c Subs seeds demde pt hA E o b ELS VVVVVVVVVV VV VV VV VY lt lt Press ESC key to return to Main Menu or enter a command gt gt Press A from the above Controller Setup menu to set up system configuration Then move the cursor at TSI Function option and use TAB or key to set TSI Function as 1 N Multicast Press ESC to return to the Controller Setup menu LOOP AM3440 C System Setup SYSTEM 16 42 59 09 09 2011 Please nput decimal number 0 9 BACKSPACE to edit System Time Date 16 42 59 09 09 2011 Device Name LOOP AM3440 C Network NI EN IPAddress SubnetMask Frame LB Timer LAN ON 192 168 014 189 255 255 255 000 Ethernet WAN OFF 010 010 012 002 255 255 255 000 HDLC 00000001 Gateway Interface LAN Gateway IPAddr 192 168 014 254 CONSOLE port Baud Rate 9600 Data Length 2 GABLES Stop Bit I ISBt Parity NONE XON XOFF XOFF TSI map TSI Function 1 N Multicast Clock Mode Normal dle Signalling 1010 lt lt Press ESC key to return to previous menu gt gt 69 Chapter 6 Terminal Operation Before setting TSI map for this 1 N Multicast TSI function make sure the previous TSI map setting is
155. line Power Fan tray required Z e amp w o o 4 channel G SHDSL 1 pair with line power Fan tray required N A N A N A 182 Chapter 13 Appendix G AM3440 C Power Consumption Note N A Not Applicable W Watt and w o without To calculate actural power consumption including power used to drive telephone and remote unit through line power 183
156. ll the CPU interface out from the main chassis Then adjust jumper 1 to be ON please see also below diagram Download AM3440_T RUN to bank 1 after plugging the CPU board into the main chassis After the download is completed adjust the jumper 1 to be OFF Then reboot the system 81 Chapter 6 Terminal Operation JUM1 CPU Interface ON e e OFF A 4 Download the file strapper rom to boot up code Under File Transfer menu press E to get into the submenu to download the file NOTE Do not reboot now LOOP AM3440 C File Transfer 11 46 58 12 05 2008 Download Mainboard Firmware Upload Mainboard Firmware Download Configuration Upload Configuration Download Mainboard Boot up gt Copy Firmware to Redundant UbmUOtU s lt lt Press ESC key to return to Main Menu or enter a command gt gt 82 Chapter 6 Terminal Operation LOOP AM3440 C Download Bootup Code 11 48 58 12 05 2008 ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn BACKSPACE to edit Current boot up version V5 01 01 11 22 2007 TFTP Server IP 000 000 000 000 Download File Name lt lt Press ESC key to return to previous menu gt gt A 5 After downloading V3 xx runcode to bank2 reset the system to enable the new firmware NOTE If you want bank 1 to has the sa
157. lot start slot clock loss primary start redundant loss backup switch power fail redundant chksum error fan fail map switch link protection redundant insert redundant unsync redundant to primary card type mismatch link id mismatch power consumption alarm ssm clock switch supv log in out 163 Chapter 10 Appendix D LOOP AM3440 C ALARM TRAP INFORMATION 10 6 ccAlarmType unit alarm ccAlarmType for unit alarm has two formats Vendor Spec and Assigned Vendor Spec is the original format that displays only the alarm number Assigned is the new format that displays the alarm type description Select the format in V1 Trap Setup Commad Path Main Menu S System Setup gt S SNMP Setup gt B V1 Trap Setup The alarm type on the SNMP screen will show in the format that you choose Note E amp M FXO FXS and TS card do not have alarms so there is no alarm type to these cards For RS232 and EIA530 please refer to DTE A alarm type table 1 E1 Card Vendor Spec Assigned Alarm type 21 e1 rai 201 RAI 22 e1 ais 202 AIS 23 e1 los 203 LOS 24 e1 lof 204 LOF 25 e1 bpv 205 BPV 26 e1 es 206 ES 27 e1 uas 207 UAS 28 e1 css 208 CSS 2 T1 Card Vendor Spec Assigned Alarm type 21 t1 yel 221 YEL 22 t1 ais 222 AIS 23 t1 los 223 LOS 24 t1 lof 224 LOF 25 t1 bpv 225 BPV 26 t1 es 226 ES 27 t1 uas 227 UAS 28 t1 css 228 CSS 3 DTE A V 35 X 21 V 36 5RS232 5X50 Card Vendor Spec Assigned Alarm type 20 dte unsync 501
158. mainboard firmware and R to copy firmware to redundant Note Check the current hardware version before firmware upgrade Make sure the existing hardware version is compatible to the updated firmware version For more details please see the backward compatibility chart LOOP AM3440 C P gt gt 5 gt gt File Transfer Download Mainboard Firmware Upload Mainboard Firmware Download Configuration Upload Configuration Download Mainboard Boot up Copy Firmware to Redundant lt lt Press ESC key to return to Main Menu or enter a command 18 49 01 12 04 2008 gt gt 76 Chapter 6 Terminal Operation 6 2 9 1 Download Mainboard Firmware LOOP AM3440 C Download Firmware 18 52 13 12 04 2008 ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn BACKSPACE to edit Firmware 1 Version 2 W3 04 03 09 10 2008 Firmware 2 Version V7 05 01 10 28 2008 Current Firmware Bank 2 Next Boot Firmware S 22 TFTP Server IP 000 000 000 000 Firmware File Name lt lt Press ESC key to return to previous menu gt gt 6 2 9 2 Upload Mainboard Firmware LOOP AM3440 C Upload Firmware 18 52 54 12 04 2008 ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn BACKSPACE to edit Firmware 1 Version V7 04 03 09 10 2008 Firmware 2 Version SOM 05 01 10728720058 Current Firmware Bank 2 TFTP Server IP 000 000 000 000 Firmware File Name Firmware Ban
159. maintenance and administration a CONSOLE port with DB9 connector is located on the front panel see also Figure 2 1 The RJ45 connector is for an Ethernet connection For direct modem or VT 100 terminal connection use a null modem cable to connect the CONSOLE port on the front panel NOTE When AM3440 C is plugged with two CPU cards both of these two CPU cards can be primary master or redundant slave which only depends on which CPU card completes boot up first after powering on the main unit User can tell which CPU card is primary or redundant from the status of CPU card s ACTIVE led If ACTIVE led is flashing green the CPU card is primary When one CPU fails the other becomes master and remains master even when the failed is replaced Chapter 2 Installation 2 3 1 Chassis Grounding The chassis ground screw is located in the right hand side of the rear panel Grounding Screw Figure 2 1 Ground Screw Location When attaching a ground wire to the chassis ground screw please follow these instructions e Use copper grounding conductors of 18 AWG e Conductors should not be of dissimilar metals e bare conductors should be coated with anti oxidant before crimp connections are made e Anyunplated connection surfaces connectors braided strap and bus bars must be bought to a bright finish and coated with anti oxidant before connections are made 2 3 2 Electrical Installation Guide The application drawing of DC pow
160. me firmware as bank 2 s please followe below procedures 1 Make sure the current firmwre bank is bank 2 2 Then download V3 xx runcode to bank 1 3 Rest the system to enable the new firmware 83 Chapter 6 Terminal Operation Download Firmware Procedure B B 1 Connect the Ethernet port of the AM3440 to the TFTP server Ethernet port B 2 Click the TFTP server icon on your PC screen to run the TFTP program A screen will be shown with your PC s IP address displayed Left click your mouse on the Settings button a m My Documents 32 by Ph Jour Base Directo Browse Server interfaces 132 168 100 206 21 Srowpi SNMPc 5 0 Curent Action Listening on port 69 Recycle Bin Cutftp32 rom rom Ide __ Settings Hep a download Tftpd32 E Hyperterm 500 2s run Stat R Loom SeTFTPD32 by Ph Jounin BOB 1200 B 3 Hook up the COM PORT 1 of the VT100 PC running VT100 emulation to the AM3440 through the front console port B 4 Run a VT100 terminal after connecting to the AM3440 B 5 Under the main menu press W to enter into the File Transfer menu B 6 Under the File Transfer menu press A Press A to download mainboard firmware B to upload mainboard firmware and R to copy firmware to redundant LOOP AM3440 C File Transfer 11 50 55 12 05 2008 Download Mainboard Firmware Upload Mainboard Firmware Download Configuration
161. mware press G from the Port Menu The screen will show as below ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn BACKSPACE to edit Bank 1 Firmware Ver V2 01 02 04 27 2006 Good Bank 2 Firmware Ver V2 01 02 04 27 2006 Good Working Firmware Bank 1 TFTP Server IP 7010 003 0 05 0 011 Firmware File Name lt lt Press ESC key to return to previous menu gt gt 6 3 8 DTE board Return to Default Press to return to default LOOP AM3440 C Download Firmware 15 43 46 12 10 2008 Choose DTE Port Return to Main Menu SLOT 1 DTE PORT 1 Port Menu 15 44 19 12 10 2008 Version SW V2 01 02 04 27 2006 DISPLAY SETUP C DTE Configuration S gt System Setup DTE Status L Loopback Test H gt Alarm History M gt Alarm Setup G Upgrade Firmware LOG MISC F gt Log Off O Log On B gt DTE board Return to Default U gt Choose Other Slot Z Card Reset p Return to default are you sure Y N 104 Chapter 6 Terminal Operation 6 3 9 Card Reset To reset DTE board press Z SLOT 1 DTE PORT 1 Port Menu 15 44 19 12 10 2008 Version SW V2 01 02 04 27 2006 DISPLAY SETUP C DTE Configuration S gt System Setup I DTE Status L Loopback Test H Alarm History M gt Alarm Setup G gt Upgrade Firmware LOG MISC F gt Log Off O Log On B DTE board Return to Default
162. n Download Firmware Procedure The detailed procedure for download firmware is shown below 1 Telnet to the Network Equipment NE and save the configuration Upgrade the Software to the backup bank of the Primary CPU card Copy the firmware to redundant CPU card Reset the redundant CPU card Copy the firmware to redundant CPU card again Reset the redundant CPU card again When the redundant is booted up it will run the new Software in both banks Reset both CPU cards Upon bootup both CPU cards will run the new firmware N N Download Firmware Procedure A NOTE This NOTE is for Download Firmware Procedure A only User is not allowed to download firmware to redundant CPU card by using R command of File Transfer menu For downloading firmware to the redundant CPU card please repeat the Download Firmware Procedure A A 1 Under Controller Menu press W to enter into Firmware Transfer menu LOOP AM3440 C Controller Menu 11 28 39 12 05 2008 SIOE 5 Serial Number 123472 Redundant Controller Disabled Hardware Version Ver G Start Time 09 55 17 12 05 2008 Software Version V7 05 01 10 28 2008 Device Name LOOP AM3440 C DISPLAY SETUP C gt System Configuration S gt System Setup B gt Clock source Configuration gt System Alarm Setup Q gt Alarm Queue Summary W Firmware Transfer Information Summary V Store Retrieve Configuration
163. n the last N393 events N393 Error count See N392 130 Chapter 6 Terminal Operation These parameters must be coordinated with the ATM network parameters The procedure for changing Port FR Management setting which has been saved in the system are Important 1 Go to Port Connection Table Setup screen as the 2nd screen shows Note 2 Then change CH from 04 to 00 as the 3rd screen shows 3 Go back to Port FR Management Setup screen as 1st screen shows to change the previous setting 1st screen SLOT D ATM FR E Port FR Management Setup 10 25 33 09 13 2002 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS CH Active Protocol Direction Tse T3S92 INSEL INSSZ INS93 1 YES FR ITU Network 0 5 006 03 04 2 YES HDLC 3 YES FR ITU Network 0 5 006 03 04 4 YES HDLC 5 NO FR ITU Network 0 5 006 03 04 6 NO FR ITU Network 0 is 006 03 04 7 NO FR ITU Network 0 5 006 03 04 8 NO FR ITU Network 0 9 006 03 04 9 NO FR ITU Network 0 5 006 03 04 10 NO FR ITU Network 0 5 006 03 04 ld NO FR ITU Network 0 5 006 03 04 12 NO FR ITU Network 0 2 006 03 04 13 NO FR ITU Network 0 5 006 03 04 14 NO FR ITU Network 0 5 006 03 04 15 NO FR ITU Network 0 5 006 03 04 16 NO FR ITU Network 0 5 006 03 04 lt lt Press ESC key to return to previous menu gt gt 2nd screen SLOT D ATM FR El Port Connection Table Setup 10 25 48 09 13 2002 Please Input 1 10
164. nagement channel with GUI are available In addition to the LCD display there is LED indication for all plug in cards Finally the Loop AM3440 C consists of a rugged chassis made from reinforced aluminum giving this equipment a more durable structure and a longer physical life For Loop VV Y BOX Loop VV Y BOX is designed to provide 1 for 1 protection function for Quad E1 interfaces of AM3440 shelf Two kinds of connector type are available for Y BOX BNC connector and RJ48C connectors Each Y BOX with BNC connectors support 1 for 1 protection function for 2 Quad E1 interfaces of AM3440 and each Y BOX with RJ48C connectors support 1 for 1 protection function for 8 Quad E1 interfaces of AM3440 1 2 Physical Description Although it can be used as a desk top unit the Loop AM 3440 is designed for rack mounting Typically this unit is to be installed in a Central Office location and is available with choice of a single or dual 48 Vdc 100W or single AC power supply The front of the unit can accept El ATM Frame Relay FOM Router G SHDSL Dry Contact B 703 C37 94 TDMoE Data Bridge DTE V 35 V 36 X2 1 V 11 EIAS30 RS449 RS232 Conference E amp M Maganeto FXS FXO and TS interface lines in 4 mini slots and 3 single slots Also there is a console port for connection to a VT 100 terminal 1 3 9110 oo lt 2 Plug in 1 E H i Sena eae Dual slot plug in cards Single Slot plug in C
165. nagement in the follow procedure 1 Set Network Info in Controller Menu S System Setup 2 Set Trap IP Address and its community in Controller Menu gt S System Setup gt S SNMP Setup gt B V1 Trap Setup 3 Set TSI Map in Controller Menu gt S System Setup C TSI Map Setup Configure Network Info 1 Set WAN to ON 2 Key in WAN s IP address and SubnetMask 3 Set to HDLC PPP 4 Set Gateway Interface to WAN 5 Key in the Router IPaddress which is for routing as Gateway IP Address When done press ESC to return to the Controller Setup Menu LOOP AM3440 C System Setup SYSTEM 17 38 18 09 13 2011 Please Input decimal number 0 9 BACKSPACE to edit System Time Date z 17 38 18 09 13 2011 Device Name LOOP AM3440 C Network NI EN IPAddress SubnetMask Frame LB Timer LAN ON 192 168 014 189 255 255 255 000 Ethernet WAN ON 00000001 Gateway Interface Gateway IPAddr CONSOLE port Baud Rate 8600 Data Length 8 Bits Stop Bit 5 k Bae Parity NONE XON XOFF XOFF TSI map Clock TSI Function 1l 1 Bidirection Clock Mode Normal dle Signalling 1010 Configure Trap IP address and its community Controller Menu gt S System Setup gt S SNMP Setup gt B V1 Trap Setup Make sure to set the Trap system IP to WAN LOOP AM3440 C Trap and Community 11 47 55 09 29 2011 ARROW KEYS CURSOR MOVE Please Input nnn nnn nnn nnn BACKSPACE to edit Get C
166. nector 120ohm RJ48 Line Distance Up to 500 meters Loopack DTE Payload Loopback Local Loopback Chapter 1 Product Description DTE Interface Data Bridge Card Data Port Feature Data Rate Bridge function Asynchronous 8 port data bridge card each card supports up to 120 DSO for data bridge 20 end points per multi drop circuit to into a logical ended 56K or 64K channel Per port supports bridge function to N remote Trib Site N 1 20 Support to receive 1200 to 19200 bps asynchronous data via oversampling channel One port with one DS 0 to many Maximum is 20 for remote Tributary data box 20 drops for each DSO to remote Tributary data box and 8 ports RS232 shared the 128 channels C37 94 Interface Source Wavelength Conncetor Optical Budget Dry Contact Interface Inputs 8 channel 2 port per card 4 pair per port Connector RJ45 Internal Resistance 1K Activation Current 3 ma Deactivation Current 1 5 ma Allowable Current 4 ma Contact current A Contact voltage V Dry Contact Type B Interface Inputs 8 channel 2 port per card 4 pair per port Connector RJ45 Internal Resistance 100 Activation Current 3 ma Deactivation Current 1 5 ma Allowable Current 4 ma LED 820 nm 2Km reach ST 50 Mircon core 9 6 db 62 5 Mircon core 15db Outputs 8 cha
167. ng LOOP AM3440 C System Setup MAP 15 03 38 12 12 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO MAP 1 Target In Band source DTE A Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS Slot 1 Port 2 Td 1d 4 3 1 17d 4 3 17 TuS c2 001 Zub Au Sr x 18 d 4 31598 3d 4 3 3 19d 4 3 19 4d 4 3 4 20d 4 3 20 T S 01 5d 4 3 5 21d 4 321 Clear No 6d 4 3 6 22d 24 23 22 d v sod 7d 4 3 7 23d 4 3 23 8d 4 3 8 24d 4 3 24 9d 4 3 9 25 a 4 3 25 Source 10 d 4 3 10 26 d 4 3 26 Slot 1 11 4 CHE E 27d 4 9 4221 Port Pl 12d 4 3 12 28d 4 3 28 Tom T3 a Au SAS 29 d 4 3 29 14 d 4 3 14 30d 4 3 30 Confirm Yes 15d 4 3 15 31 d 4 3 31 16 d 32 d lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt 8 Ring Enabling From the Master Unit AM 3440 C Controller Setup screen press R to set up PDH Ring Protection 174 Chapter 11 Appendix E Setting up an AM3440 C PDH Shared Protection Ring LOOP AM3440 C Controller Setup 15 48 03 03 24 2008 System SNMP Setup Password gt TSI Map Setup Select a New TSI Map Copy a TSI Map to Another Clear a TSI Map Command Line gt nit New Card Clear Empty Slot gt Link Backup Function QDS1 1 1 Protection gt DSO0 SNCP Setup PDH Ring Protection gt PDH Ring Diagnostic gt SNT
168. nnel Connector Initial Insulation Resistance Max Current Max Voltage Outputs 8 channel Connector Initial Insulation Resistance Max Current Max Voltage 8 pair per card Screw type Min 100M ohm at 500 Vdc 5A 100 Vdc 250 Vac 8 pair per card Screw type Min 1000M ohm at 500 Vdc 2A 220 Vdc 250 Vac Voice Card Q2EM Q4EM Connector Alarm Conditioning Encoding Impedance Longitudinal Conversion Loss Longitudinal Balance Gain Adjustment all port settings Signal Distortion Frequency Response Idle Channel Noise Signaling In band signaling tones Modems Voice Card 8EM Connector Alarm Conditioning Encoding Impedance Gain Adjustment Per port setting 1 0 Power Range Gain Variation Frequency Response Longitudinal Conversion Loss Total Distortion Idle Channel Noise Carrier Connection Wire Mode Signaling Modems Chapter 1 Product Description DB44 connector with external DB44 to 4 RJ45 connector cable CGA busy after 2 5 seconds of LOS LOF A law or u law user selectable per card Balanced 600 ohm or 9000hm gt 46dB gt 63dB 0 3 6 or 7 dB for transmit D A gain 0 3 6 or 10 dB for receive A D gain gt 25dB with 1004 Hz OdBm input 0 5 to 0 9 dB from 300 to 3400 Hz Max 65 Type I Il Ill IV V and TO Transmit Only signaling options manufacture option Side A or B manufacture option Wire 2 wire or 4 wire manufactu
169. nnel RS232 with X 50 subrate 8 LAN port 64 WAN port Router B 6 channel V 35 5 channel RS232 with X 50 subrate 6 channel U 10 channel U 3 channel MDSL 1 channel and 4 channel low speed optical C37 94 8 channel 2W AW E amp M 12 channel and 24 channel FXS 32 WAN port Router 12 channel and 24 channel FXO 1 channel E1 ATM Frame Relay 1 channel T1 ATM Frame Relay 12 channel Magneto 4 channel E1 4 channel T1 3 channel MDSL A 6 channel V 35 A 4 channel G SHDSL 1 pair w o line power 2 channel G SHDSL 2 pairs w o line power 8 channel G 703 card at 64 Kbps data rate Mini Quad E1 Mini Quad T1 8 channel Dry Contact I O Fiber optical interface 64 WAN port Router A Controller Conference card 3 channel E1 3 channel T1 future option TDMoE 8 channel Data Bridge Card Single port DTE for 4200 6 channel X 21 A 6 channel V 36 A 6 channel RS422 A 6 channel EIA530 A RS449 A Unknown card type 162 10 3 MIO 10 4 gt 10 5 Chapter 10 Appendix D LOOP AM3440 C ALARM INFORMATION ccAlarmSlot Slot index Number Slot Number SIot A Slot B Slot C Slot D Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 ccAlarmPort Port index Number Port Number Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 Port 8 Port 9 Port 10 Port 11 Port 12 ccAlarmType 20 controller alarm Number Alarm type alarm cut off slot no work s
170. o 4 3 Near End Loopback The near end loopbacks such as local loopback line loopback payload loopback DTE loopback are activated by the AM3440 The loopbacks are at the near end facility NOTE Deactivate the near end loopbacks from the terminal depending on where it was activated 4 4 Far End Loopback Far end loopbacks remote line loopback remote payload loopback remote channel loopback and DTE loopback can be activated by the local AM3440 to cause a remote loopback commands to the far end facility 4 5 Test Pattern To test the DS1 line four test patterns are available to determine faults such as deficient clock recovery fault ALBO level recovery inadequate jitter margin presence of bridge taps and mis optioned network interface These four patterns are framed pattern with proper DS1 frame pattern as described in the following paragraph 4 6 Verifying Loop AM Operations The purpose of this section is not to help the user determine where a possible fault in the network may lie For this the user needs to know the exact geometry of the network Then standard network trouble shooting procedures should be followed which involve sectionalizing the network and performing loopback tests on pieces of the network The purpose here is to help the user determine whether the Loop AM equipment is at fault after tests have pointed a suspicious finger at this equipment The procedures outlined here depends on test equipment and o
171. o 3400 Hz coincide with ITU T G 712 Max 65 dBm0p 0 5dB Ringing REN 0 5B AC Detectable Ringing 25 Vrms Loop Resistance lt 1800 Q DC Impedance ON HOOK gt 1 0 DC Impedance OFF HOOK 235 25 mA feed 90 100 mA feed Normal 48 Vdc with 25mA current limit Normal Automatic Ring down 1 REN at 5K meters per port 16 7Hz 20Hz 25Hz 50Hz user selectable for all ports 38 to 85 Vrms sine wave 76 Vrms for default Ring Voltage 2 sec on 4 sec off or 1 sec on 2 sec off optional for PLAR Loop Start DTMF pulse PLAR Battery Reverse Ground Start Metering pulse 12 KHz 16 KHz and P in PLAR mode PLAR signalling bits are programmable Programable bit e All in band signaling tones are carried transparently by the digitizing process e Customer is responsible for in band signaling compatibility between a telephone and a switch or between a PBX and a Switch Chapter 1 Product Description TDMoE Combo Gigabit Ethernet GbE Interface Number of Ports 2 Speed 10 100 1000M bps Connector RJ45 for twisted pair GbE LC for optical GbE auto detection Gigabit Ethernet GbE Interface Number of Port 2 Speed 10 100 1000 BaseT Connector RJ45 Ethernet Function Basic Features MDI MDIX for 10 100 1000M BaseT auto sensing Ping function contained ARP Per port programmable MAC hardware address learn limiting max MAC table 8192 8k entry Packet Delay Variation Unframed T1 Up to 340 ms Framed T1 U
172. odel Backup Link Backup Fun OFF Link Status Normal Force Switch Note Please If protection check both backup link have the same FRAME and CAS setting type changed ex from 1 1 to 141 Please re setup map 6 2 1 7 QDS1 1 1 protection Controller Menu gt C System Configuration gt Q QDS1 1 1 protection This function display the current QDS1 1 1 protection status Below sample shows the port 1 and port 2 of slot 1 2 as circuit protection LOOP AM3440 C QDS1 1 1 Protection 10 39 53 09 29 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Protect Pair Master Backup Port 1 Port 2 Port 3 Port 4 Slot B FE1 FE1 PATES SEE SN ASE tmc TES SuSE SIrot C D FOM FOM Ses TES ESS Slot 1 32 QuadE1 QuadE1 CIRCUIT CIRCUIT DISABLE DISABLE Slot 3 4 0 399 295 XM S SSS Slot 9 6 4 ee a muc cadcm Protection Working Port Port 1 Port 2 Port 3 Port 4 Slot A B 1 1 Slot FOM FOM Slot 1 2 QuadEl QuadEl 1 1 1 2 Slot 3 4 Slot S 56 4 If protection type changed ex from 1 1 to 1 1 Please re setup map lt lt Press ESC key to return to previous menu gt gt 47 Chapter 6 Terminal Operation 6 2 1 8 DSO SNCP Status Controller Menu gt C System Configuration gt K DS0 SNCP Status This function is to view the current status of DSO SNCP LOOP AM344
173. oller Setup menu gt gt 12 04 2008 of the following is enabled 73 Chapter 6 Terminal Operation Enable MAP 3asthe current TSI map Then press Y to confirm the setting or N to abort To save the new map configuration to flash memory press V from the Controller Menu LOOP AM3440 C System Setup New map 18 44 38 12 04 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Last activated TSI Map MAP 3 Change to TSI Map MAP 3 This item will be ignored if anyone of the following is enabled TSI Map switch start hr min Mapl DISABLE 00 00 Map2 DISABLE 00 00 Map3 ENABLE 00 00 Map4 DISABLE 00 00 lt lt Press ESC to return to Controller Setup menu then Press D to active gt gt 74 Chapter 6 Terminal Operation 6 2 8 System Alarm Setup Under the Controller Menu press M to set up system alarm as below The alarm action includes Disable Enable and each supports different alarm commands Please refer to Appendix D Alarm Setup Indication for setup detail The Alarm Relay is applied to configure the Alarm Relay output present on the front panel of AM3440 controller The alarm relay circuit will be triggered when an alarm is detected To return the alarm relay to the normal state the user has three options to choose from The detailed description for each option is listed below AUTO The alarm relay will return to normal state once the problem of all
174. ommunity public Set Community public Trap IP 1 192 168 1 254 _ Community Name public Trap IP 2 000 000 000 000 Community Name public Trap IP 3 000 000 000 000 Community Name public Trap IP 4 000 000 000 000 Community Name public Trap IP 5 000 000 000 000 Community Name public Trap system IP WAN Alarm Trap Type Vendor Spec TrapObject Type Vendor Spec lt lt Press ESC key to return to previous menu gt gt 152 Chapter 8 Appendix B Inband Management Configure TSI Map Controller Menu gt S System Setup C TSI Map Setup In the example below to map Time Slot 1 of Slot A to Time Slot 1 of the IB In band Port for this purpose When you have completed your TSI map press ESC to return to the Controller Setup menu Then press D from that menu to activate the new map LOOP AM3440 C System Setup MAP 11 49 17 09 29 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS MAP NO MAP 1 Target El NON CAS Source In Band Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS Slot 2 Port 1d IB 1 17 d ld A 1 FO 2 d 18 d Sr 19 d 4d 20 d T S 4 2 OL 5d 21 d Clear No 22 d d v sod 7 d 23 d 8d 24 d 9 d 250 Source 10 d 26 d Slot IB 11 d 27 d Port 12 6 28 TOSS sel 13 d 29 d 14 d 30 6 Confirm Yes 15 d 31 d 16 d lt lt Press ESC to return to Controller Setup menu
175. ot 3 4 as circuit protection It means Slot 3 port 1 is protection working port and slot 4 port 1 as backup in Circuit mode LOOP AM3440 C QDS1 1 1 Protection 18 07 22 09 13 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Protect Pair Master Backup Port 1 Port 2 Port 3 Port 4 Slot A B FE1 FE1 J SSSR SSSR S Slot C 2D FOM 22cm c succ uc Slot 1 2 QuadEl je wA LBDODnOO SSSSsSsasoS Slot 3 4 QuadE1 QuadE1 CIRCUIT LINE NONREV 1 1 NONREV DISABLE Slot 5 6 Protection Working Port Port 1 Port 2 Port 3 Port 4 Slot A B FE1 FEL Slot C FOM Slot 1 2 QuadE Slot 3 4 QuadEl QuadEl 3 do 3 5 2 Slot 5 6 If protection type changed ex from 1 1 to 1 1 Please re setup map gt gt Change configuration Y N Note to save please use V command Note Protection Working Port Port 1 Port 2 Port 3 Port 4 Slot 3 4 QuadE1 QuadE1 Bok 32 3253 Definition 3 1 means Slot 3 port 1 3 2 means Slot 3 port 2 and etc 156 Chapter 9 Appendix C QDS 1 1 1 Protection Force Switch Configuration The protection Setup must be set before the status setup Go to Controller Menu gt S System Setup gt Q QDS1 1 1 Protection select Status and press Enter The Status menu is to setup the ForceSwitch for each protection pair and po
176. p to 256 ms Et up to 256 ms Framed T1 with CAS Up to 192 ms Packet Transparency Packet transparency support for all types of packet types including IEEE 802 1q VLAN and 802 1ad Q in Q QoS User configurable 802 1p CoS ToS in out going IP frame Traffic Control Ingress packet Rate limiting buckets per port for ethernet port Supporting Rate based and Priority based rate limiting for LAN port Granularity a From 64 Kbps to 1 Mbps in increments of 64 Kbps b From 1 Mbps to 100 Mbps in increments of 1 Mbps c From 100 Mbps to 1000 Mbps in increments of 10Mbps Pause frame issued when the traffic exceeding the limited rate before packet dropped following IEEE802 3X Jitter amp Wander PPM per G 823 Traffic PPB per G 823 Synchronous Standard Compliance IETF TDMoIP RFC5087 SAToP RFC4553 CESoPSN RFC5086 IEEE 802 1q 802 1p 802 1d 802 3 802 3u 802 3x 802 3z 802 1s 802 1w 10 Clock Source Chapter 1 Product Description Internal Line Interface External E 1 11 2048 KHz Alarm Relay Alarm Relay max voltage 3Vdc max currnet 1A Fuse alarm and performance alarm System Confiquration Parameters Active Configuration Stored Configuration and Default Configuration Stored in Non volatile Memory Management Console Ethernet Inband Management Ethernet LCD Performance Monitor Performance Registers Separate Registers Performance Reports Alarm Queue Threshold Diagnostics
177. particular plug in card as the protected unit and confirm with the setting LOOP AM3440 C DSO SNCP Creation 09 49 12 10 09 2009 Please Input decimal number 1 31 BACKSPACE to edit Protection Group Creation Using map 1 Total DSO SNCP 5 Protected Slot A El E E NAT Port NON CAS Tag 20 Count 05 Primary Shot 3E WT WANT A E DEC Se le See wed Port P NON CAS Protection Delay 00 TS Upstream Send AIS On Secondary Slot 2 35 le BROO RSA I Port P NON CAS Protection Delay 00 l9 0 Upstream Send AIS On Switch Mode Non revertible Confirm Yes lt lt Press ESC key to return to previous menu gt gt 51 Chapter 6 Terminal Operation 6 2 7 System Setup Controller Menu gt S System Setup For details see the following sections LOOP AM3440 C Controller Setup 15 34 32 09 09 2011 System SNMP Setup Password TSI Map Setup Select a New TSI Map Copy a TSI Map to Another Clear a TSI Map Command Line nit New Card Clear Empty Slot Link Backup Function QDS1 1 1 Protection DSO SNCP Setup PDH Ring Protection PDH Ring Diagnostic SNTP Setup TELNET SSH Setup Power Setup VEOAZHADWDNRONDGHHAAAVAWUHN PS WMDs CDS Vb D RE ee b RER ol V VV VV V VV VV V VV VV VN OV lt lt Press ESC key to return to Main Menu or enter a command gt gt 6 2 7 1 System Under th
178. r Performance Report uie te eere xe eise e pen vehe ret eee CERES Ua Rusia 111 6 5 2 24 Hour Performance Report s e e ee dinars Ve e Labbe o des 115 6 5 3 Port Statisties EE 117 6 5 4 Unit Configuration 3 5e s Pere tn AE EE E 119 6 5 5 AlarnbiHistory ts au RR RE RI RE D n duc 120 6 5 6 Ido E 121 6 5 7 Alarm Queue son iet nue eiiam 124 6 5 8 Loopback Test aio E ne te et oboe Ga tes dde ere pede 124 6 5 9 eoe reni E UE 125 6 5 10 AM3440 C TSI MAP Setup 126 6 5 11 SySIem Stipendio n etre nO 126 6 5 12 Clear Alarmi 136 6 5 13 Glear Performance D td iut e E nn 137 6 5 14 Upgrade FitmWQtfes aac tete tete ee cde Roger 137 6 5 15 Unit Load Default Configuration eate tier t ete gite eed ee et pene tbe peu beet 136 6 5 16 E E 138 6 6 MINI OUAD ELSUB MENU 5388 Rr ete dde A eee 138 6 6 1 Unit 1 Hour Performance Report 4 eere Roe YR E EYE tir t sert eame ed 139 6 6 2 Unit 24 Hour
179. re option transparent Full compatibility with V 90 modems Eight RJ45 CGA busy after 2 5 seconds of LOS LOF A law or u law user selectable together for all Balanced 600 or 900 ohms 16 to 7 dB 0 1dB step for transmit D A gain 16 to 14 dB 0 1dB step for receive A D gain A D Analog input level 66 dBm 0 00039 Vrms 3 dBm 1 09 Vrms D A Analog output level 66 dBm 0 00039 Vrms 4 dBm 1 22 Vrms 0 5 dB at 0 input 0 5 dB at 0 dBm0 input gt 46dB gt 35 dB at 0 dBm0 input 65 Side exchange side Side carrier side setup by side switch 2 wire and 4 wire programmable Type 1 Type 2 Type 3 Type 4 and Type 5 Transmit only programmable Full compatibility with V 90 modems All in band signaling tones are carried transparently by the digitizing process Customer is responsible for in band signaling compatibility between a telephone and a switch or between a PBX and a switch Voice Card 12 MAG Magneto Connector Alarm Conditioning Encoding Impedance Longitudinal Conversion Loss Gain Adjustment Signal Distortion Frequency Response Idle Channel Noise Min Detectable Ringing Voltage Ringing Detectable Across Ringing Generation Ringing Send Across Signaling Signaling Bit A B C D Twelve RJ11 CGA busy after 2 5 seconds of LOS LOF A law or u law user selectable together for all Balanced 600 or magneto telephone impedance match
180. rn ENTER key accept change gt gt LOOP AM3440 C Init a New Card 18 53 43 08 01 2011 63 t Chapter 6 Terminal Operation 6 2 7 10 Clear Empty Slot Controller Menu gt S System Setup gt J Clear Empty Slot This function is to clear the empty slot The sample below shows to select B than press enter to accept LOOP AM3440 C Clear Empty Slot 10 43 10 11 26 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Slot Registered Model State Slot Registered Model State A 5 B Router A unplugged C D 1 2 G703 unplugged 3 DTU 6 unplugged 4 LS OPTICAL unplugged This command will clear the related TSI and clear the slot with ZERO Select Slot B lt lt Press ESC key to return to previous menu gt gt The setting is completed You can move to another slot if any LOOP AM3440 A Clear Empty Slot 10 43 10 11 26 2008 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Slot Registered Model State Slot Registered Model State A 5 B Router A unplugged C D L 2 G703 unplugged 3 DTU 6 unplugged 4 LS OPTICAL unplugged This command will clear the related TSI and clear the slot with ZERO Select Slot 2 Clear OK lt lt ESC key ignore and return ENTER key accept change gt gt 64 Chapter 6 Terminal Operation 6 2 7 11 Link Backup Function For Linkbackup screen please refer to Appendix A 6 2 7 12 QD1 1 1 Protection For detail of QDS1
181. rrent 15 Min 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 Current 24 Hour 2 USER 5 Last 96 15 Interval OI 0B gt lt lt TAB key to show Performance Report gt gt lt lt ESC key to return to previous menu SPACE key to refresh gt gt 6 5 2 2 ATM Frame Relay E1 Press 2 from the port menu the following screen will show To view ATM FR E1 port 24 hour performance report by selecting register type The current selection will be highlighted by an asterisk SLOT D USER ES Valid Seconds in Current 15 Min Inte Valid 15 Min Intervals in Current 24 ES Current 15 Min Interval 0 Current 24 Hour Interval ATM FR El USER ES 01 08 gt 09 16 gt E724 33 40 gt 41 48 49 56 gt 57 64 gt 65 72 x Last 96 15 Min Interval lt lt TAB key to show Statistics Report gt gt lt lt ESC key to return to previous menu Port 24 Hour Perf Report rval 46 seconds Hour Interval O0 UAS BES SES 46 0 0 DM SPACE key to refresh gt gt 16 30 29 07 24 2002 116 Chapter 6 Terminal Operation SLOT D ATM FR El Port 24 Hour Stat Report 16 30 33 07 24 2002 USER ES Valid Seconds in Current 15 Min Interval 46 seconds Valid 15 Min Intervals in Current 24 Hour Interval O0 SES SUAS SBES 5 5 SDM 058 Current 15 Min 0 0000 100 00 0 0000 0 0
182. rsion V7 05 01 10 28 2008 DISPLAY gt System Configuration B gt Clock source Configuration Q gt Alarm Queue Summary gt nformation Summary R Redundant Board Information P Performance Report LOG U gt Choose a Slot F Log Off SETUP MISC Menu gt Log On SETUP MISC Menu gt gt Clear alarm queue of PORT D are you sure 17 53 09 12 10 2008 Redundant Controller Disabled Start Time 11 31 04 12 10 2008 Device Name LOOP AM3440 C SETUP 5 gt System Setup M System Alarm Setup W gt Firmware Transfer V Store Retrieve Configuration K Clock source Setup T gt Bit Error Rate Test MISC A gt Alarm Cut Off X Clear Alarm Queue Y Controller Return to Default Z Controller Reset Y N 136 Chapter 6 Terminal Operation 6 5 13 Clear Performance Data Under the port menu press K to clear performance data SLOT D ATM FR El Port Statistics gt gt Clear Statistics Type T1 E1 Line FR Statistics 15 44 43 07 24 2002 ATM Statistics 6 5 14 Upgrade Firmware Under the port menu press D to download firmware SLOT D ATM FR El Download Firmware ARROW KEYS CURSOR MOVE BACKSPACE to edit ESC to abort Bank 1 Firmware Ver V2 04 07 10 2002 Good Bank 2 Firmware Ver V2 04 06 07 2002 Good Working Firmware Bank 1 TFTP Server IP 2 15602532256 Firmware File Name 2 LV
183. rts LOOP AM3440 C 0051 1 1 Protection 15 19 15 08 02 2011 gt gt Select Setup Status The Status menu it is to setup the force switch function to the assigned port of assigned protect pair LOOP AM3440 C QDS1 1 1 Protection 17 00 00 08 02 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Protect Pair Master Backup Port 1 Port 2 Port 3 Port 4 Slot B FE1 FEL _ _ Slot C D FOM 2 Slot 1 2 QuadE1 Slot 3 4 QuadE1 QuadE1 ForceSwitch NO NO Slot 5 6 Protection Working Port Port 1 Port 2 Port 3 Port 4 Slot B FE1 FEL Slot C D FOM Slot 1 2 QuadE1 Slot 3 4 QuadE1 QuadE1 325 3722 3 3 Slot 5 6 lt lt ESC key ignore and return ENTER key accept change gt gt Function Option Default ForceSwitch NO ForceSwitch NO Press Enter to accept change and key in Y to change the configuration Change configuration Y N Note to save please use V command 9 3 Setting Up Line Protection Line protection is illustrated in Figure below It does NOT require the use of a Loop VV Y BOX Quad E1 E1 Line Quad E1 Card Card Quad E1 E1 Line Quad E1 Card Card AM3440 C AM3440 C
184. sel fixed first half last half odd pair even pair fixed Clock Normal Inverted Normal Data Normal Inverted Normal RTS Permanent Active Permanent TTM Off ON Off DCD Permanent ON Remote all one forward Permanent ON Data Rate Asynchronous Mux mode 1 2K 2 4K 4 8K 9 6K Independent mode 1 2K 2 4K 4 8K 9 6K 19 2K Synchronous Mux mode 1 2K 2 4K 4 8K 9 6K Independent mode 1 2K 2 4K 4 8K 9 6K 19 2K 38 4K 48K 64K 6 4 5 Loopback Test To setup the loopback test press L from the Port Menu The screen will show as below Port I TEST MENU Send BERT SLOT 3 X50 PORT 1 ARROW KEYS CURSOR MOVE RS232 Loopback Unit Loopback and Test ENTER KEY ITEM SELECT TAB OEE TO DTE OFE ON TO DS1 lt lt Press ESC key to return to previous menu gt gt 09 46 25 05 23 2001 NEXT PREV UNIT Note Pattern type of Bert is 2 15 1 108 Chapter 6 Terminal Operation 6 4 6 Alarm Setup To setup the alarm setup press M from the Port Menu The screen will show as below SLOT 3 X50 PORT 1 Alarm Setup 09 46 30 05 23 2001 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Port Alarm Relay Unit 3 1 DISABLE DISABLE Unit 3 2 DISABLE DISABLE Unit 3 3 DISABLE DISABLE Unit 3 4 Unit 3 5 gt gt Change configuration Y N Note to save please use V command 6 4 7 Upgrade Firmware To setup the upgrade firmware press G from t
185. show Performance Report gt gt lt lt ESC key to return to previous menu SPACE key to refresh gt gt 6 5 2 24 Hour Performance Report 6 5 2 1 Frame Relay T1 Press 2 from the port menu the following screen will show To view ATM FR T1 port 24 hour performance report by selecting register type and parameter The current selection will be highlighted by an asterisk SLOT D ATM FR T1 Port 24 Hour Perf Report LPL 8233 07 2147 20 02 gt gt Select Register Type USER LINE gt gt Select Parameter ES UAS BES SES CSS LOFC AS EFS BPV ESF SLOT D ATM FR T1 Port 24 Hour Perf Report 17 18 44 07 21 2002 USER ES Valid Seconds in Current 15 Min Interval 345 seconds Valid 15 Min Intervals in Current 24 Hour Interval O0 ES UAS BES SES CSS LOFC Current 15 Min Interval 0 0 0 0 0 Current 24 Hour Interval Pli RS M RE RE eee SSeS USER ES Last 96 15 Min Interval 01 08 gt lt lt TAB key to show Statistics Report gt gt lt lt ESC key to return to previous menu SPACE key to refresh gt gt 115 Chapter 6 Terminal Operation SLOT D ATM FR T1 USER ES Valid Seconds in Current 15 Min Interval 345 seconds Valid 15 Min Intervals in Current 24 Hour Interval O0 Port 24 Hour Stat Report 17 18 48 07 21 2002 SES SUAS SBES 5 5 CSS LOFC Cu
186. st configure the BERT in the exact way the Loop AM3440 is configured This is easily done by comparing each of the options one by one After checking that the configuration matches if any one of the ports fails then Loop AM3440 has failed 38 Chapter 5 Front Panel Operation 5 Front Panel Operation 5 1 Refer to AM3440 LCD separate Manual For detail please see AM3440 LCD separate Manual 39 Chapter 6 Terminal Operation 6 Terminal Operation Loop AM 3440 C provides comprehensive report and enhanced configuration capability through the console port on the front panel Using single character commands and arrow keys the Loop AM including all of its ports can be configured and monitored through the use of a VT 100 terminal The single character commands are not case sensitive On each screen the available commands and the configurable fields are highlighted When a VT 100 terminal is connected to the CONSOLE port of front panel make sure the button is up upon power up a main menu is shown The main menu consists of three groups of commands Display Log Setup and MISC Initially only Display and Access commands are available To enable Setup and MISC user has to log on using the O command after which the full screen is shown LOOP AM3440 C Controller Menu 15 14 57 09 09 2011 Slot A D 1 5 Serial Number 5 21256158 Redundant Controller Disabled Hardware Version Ver H Start Time 15 11 27 0970872011 Sof
187. t SNMP Setup C gt V3 User Based Security Model Setup B gt Password D gt V3 View Based Access Control Model Setup 1 C gt TSI Map Setup E gt V3 View Based Access Control Model Setup 2 D gt Select a New TSI Map F gt V3 Target amp Notify Setup E gt Copy a TSI Map to Another F gt Clear a TSI Map L gt Command Line gt Init New Card J gt Clear Empty Slot G gt Link Backup Function Q gt QDSI 1 1 Protection gt DSO SNCP Setup R gt PDH Ring Protection optional T gt PDH Ring Diagnostic optional N gt SNTP Setup H gt TELNET SSH Setup P gt Power Setup S gt System Setup M gt System Alarm Setup gt Download Mainboard Firmware B gt Upload Mainboard Firmware C gt Download Configuration I gt Firmware Transfer D gt Upload Configuration E gt Download Mainboard Boot up R gt Copy Firmware to Redundant I V gt Store Retrieve Configuration L K gt Clock source Setup T gt Bit Error Rate Test A gt System B gt Clock Source C gt TSI map L C gt System Configuration D gt Current TSI map E gt Power Fan Status G gt Link Backup Function Q gt QDSI 1 1 Protection K gt DSO SNCP Status L gt Clock source Configuration Q gt Alarm Queue Summary I gt Information Summary R gt Redundant CTRL Information gt Performance Report Fig
188. t gt Select Register Type USER LINE gt gt Select Parameter ES UAS BES SES CSS DM AS EFS BPV After pressing ENTER from the above screen the following screen will show up SLOT A MQuad El PORT 2 Port 24 Hour Perf Report 10 28 12 10 27 2004 USER ES Valid Seconds in Current 15 Min Interval 869 seconds Valid 15 Min Intervals in Current 24 Hour Interval 20 ES UAS BES SES DM CSS Current 15 Min Interval 0 869 0 0 0 146 Current 24 Hour Interval 0 18000 0 0 0 255 USER ES Last 96 15 Min Interval 01 08 gt 0 0 0 0 0 0 0 0 09 16 gt 0 0 0 0 0 0 0 0 lt lt TAB key to show Statistics Report gt gt lt lt ESC key to return to previous menu SPACE bar to refresh gt gt 140 Chapter 6 Terminal Operation Press TAB key to display the 1 hour statistics report as belwo shows SLOT C MQuad El PORT Port 24 Hour Stat Report 13 42 16 10 27 2004 USER ES Valid Seconds in Current 15 Min Interval 282 seconds Valid 15 Min Intervals in Current 24 Hour Interval O0 SES SUAS SBES 5 5 9CSS Current 15 Min 0 7092 0 00005 0 7092 0 0000 6 6666 0 0000 Current 24 Hour i ehe HS Ges HPSS SS Sere Se USER ES Last 96 15 Min Interval 01 08 gt lt lt TAB key to show Performance Report gt gt lt lt ESC key to return to previous menu SPACE bar to refresh gt gt
189. tatistics S Unit System Setup C Unit Configuration X Unit Clear Alarm Queue amp History H Unit Alarm History K Unit Clear Performance Data gt Unit Status D Unit Upgrade Firmware Q Unit Alarm Queue LOG MISC U gt Choose a Port Y gt Unit Load Default Config F Log Off SETUP MISC Menu Z Unit Reset O gt Log On SETUP MISC Menu E Return to Controller Main Menu gt gt SPACE bar to refresh or enter a command gt 6 5 1 Hour Performance Report 6 5 1 1 ATM Frame Relay T1 Press 1 from the port menu the following screen will show To view ATM FR T1 port 1 hour performance report by selecting register type USER or LINE The current selection will be highlighted by an asterisk SLOT D ATM FR T1 Port 1 Hour Perf Report 17 17 44 07 21 2002 gt gt Select Register Type USER LINE SLOT D ATM FR T1 Port 1 Hour Perf Report 17 17 49 07 21 2002 USER Valid Seconds in Current 15 Min Interval 290 seconds ES UAS BES SES CSS LOFC Current 15 Min Interval sr 10 0 0 0 0 0 list Nearest 15 Min Interval ss bosci ores teres 2nd Nearest L5 Man Interval ESS ESS Sesame CSST srd Nearest 15 Min Interval Hs 22 e Lese SSSR SSSR 4th Nearest L5 Min Interval sp 2 Sones SSSR SSSR Valid 15 Min Intervals in Current 24 Hour Interval 0
190. tched Once the IP parameters are set users can verify that the Loop AM is operating properly by using the ping command to check for a response from Loop AM Sping 192 1 100 45 192 1 100 45 is active The Telnet utility simulates VT 100 to connect with the Loop AM3440 controller The controller main menu of terminal screen described at Chapter 6 will be displayed after Telnet connection is established Refer to Chapter 6 to manage Loop AM controller Loop AM controller can maintain 4 Telnet connections simultaneously but only one to log on at one time 3 6 Embedded SNMP Agent The embedded SNMP agent for Loop AM offers standard RFC 1213 MIB Il and RFC 1406 051 MIB as well as Loop Telecom s enterprise MIB Network manager can use any SNMP compatible network management system such as Hewlett Packard s HP Open View to monitor and control Loop AM Please refer to each respective SNMP manager operation instruction to incorporate the Loop AM enterprise MIB to the system Figure 3 1 HDLC using Loop V 4200 E1 Loop AM 3440 C Router Loop V 4200 Telnet Station Ethernet 34 Chapter 3 Operation 3 7 In Band Management Setup In addition to the console port and the Ethernet port Loop AM 3440 C can also allow remote management through a 64 Kbps time slot from the network line To achieve remote management using this in band technique two steps are necessary First the Ethernet connection of the remote management t
191. th primary CPU Port Start up alarm control for Disable major minor critical a slot startup plug in card b primary startup first startup CPU card c redundant insert redundant CPU inserted d redundant to primary redundant CPU become to primary if primary CPU loss Clock Loss alarm control for clock loss line clock or external clock Disable major minor critical Link Switch alarm control for link switch in e1 t1 protection Disable major minor critical mechanism Map Switch alarm control for map switch timing switch Disable major minor critical mechanism Power Alarm alarm control for Disable major minor critical a power fail power card failed b fan fail fan failed c power consumption power over load 29 Chapter 3 Operation Alarm Type Alarm Description Alarm Severity Type Mismatch alarm control for Disable major minor critical a card type mimatch if plug in card different with previous record b link change if link ID different with previous record Note disable no alarm issue major issue major alarm and enable major relay if enabled minor issue minor alarm and enable monir relay if enabled critical issue critical alarm and enable major relay if enabled Table 3 4 DTE PORT Alarm Type Table Alarm Type Alarm Description Threshold V 35 slot m DTEZn UNSYNC RTS Loss V 35 interface no slot number m port number n n 1 6 Table 3 5 Alarm Type Numbers
192. ther equipment the user may have on hand The organization of these procedures start from the simple to the complex The procedure ends when a definitive conclusion is made that the Loop AM equipment is at fault To verify that the Loop AM equipment is not at fault specialized equipment such as a BERT bit error rate test set is needed 4 6 1 Quick Test 4 6 1 1 LCD Display LCD currently not available 37 Chapter 4 Maintenance 4 6 1 2 Independent Test Remove all line and interface connections to Loop AM Remove power After a few seconds re apply power Observe the power AMp self test sequence If this fails then Loop AM has failed See if the LEDs show any abnormal displays If yes use the LED indications to guide the user to test other parts of the network such as the E1 line or interface plug in Especially during initial installation excessive errors may be due to a incorrect configuration of either Loop AM or of the equipment at the other end of the line or b due to faulty line installation which results in excessive noise cross talk or impedance mismatch Especially in electrically noisy environments such as central offices use of shielded cables are mandatory 4 6 2 Substitution If a spare Loop AM plug in is available then replace the working one with the spare The user must carefully configure the spare exactly as the working one If the substitution clears the problem then the original working one is s
193. tion not supported power supplies Dual 150W Normal Single 150W Power supplies over loading gt 135W Please remove plugged in 100W 150W Power protection not supported cads or upgrade Dual 150W Power protection not supported Table 6 1 Power Consumption 46 Chapter 6 Terminal Operation 6 2 1 6 Link backup function Controller Menu gt C System Configuration gt G Link backup funcation This link backup function only apply to single E1 T1 mini slot single FOM mini slot and 1FOMA single slot Below sample is to display the the link backup function is on and the mode is non revertible The link backup function of FE1 card single E1 is Link A and Link B as backup link and FOM card mini slot is Link C and Link D as backup link NOTE Configuration for link backup will not be changed if the user turns on the backup function without selecting the backup link type or turns off the backup function without clearing the backup link type LOOP AM3440 C System Setup Backup 10 31 58 09 29 2011 ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Backup function ON 1 1 Mode non revertible Link Link A Link B Link C Link D Link 1 Link 2 Link 3 Link 4 Model FEL 1 Backup Link Link B VeUyeGue SES CESSE ESS Backup Fun OFF OFF OFF OFF OFF OFF OFF OFF Link Status Normal Normal Normal Normal Normal Normal Normal Normal Force Switch Link Link 5 M
194. to save time inactive sec Fesses gt Display or set detect time for card inactive pdh spring TS SES se gt Enable PDH SPRing need charge for password upgrade qel qtl gshdsl gt Batch download firmware of QE1 QT1 G sdhsl card mdsl dte gt Batch download firmware of MDSL DTE card dtu rs232 55e gt Batch download firmware of DTU10 RS232 card 62 Chapter 6 Terminal Operation 6 2 7 9 Init New Card Controller Menu gt S System Setup gt I Init New Card This function is to initiate the new card Below sample screen shows the status of Slot B and Slot D are mismatch Then select B and press Enter Type Y for confirmation This command will clear the related TSI and init the unit with default Select Slot B gt gt Are you sure Y N No card need initialize press any key return LOOP AM3440 C Init a New Card 10 42 02 11 26 2008 Slot Model State Slot Model State A FEL 5 B 1 mismatch 6 G 7 D FOM mismatch 8 1 2 3 4 After the initialize procedure completed go to Controller Menu gt 1 Information Summary to check the ARROW KEYS CURSOR MOVE TAB ROLL OPTIONS Slot Model State Slot Model State A FE1 5 B FEI D FOM mismatch l 2 2 4 This command will clear the related TSI and init the unit with default Select Slot D Please wait at least 10 seconds for initialize procedure lt lt ESC key ignore and retu
195. ttings ht ta rye e E gba Ve EH OPER ER PER Rs 27 3 2 SYSTEM OPERATIONS E Re e ASUNT Cer dote 27 3 2 1 SE once mi RSR EE RE A RTE es LAM LM LM RIRE 27 3 2 2 Master Clocks i intente detenti wee 27 3 2 3 CONSOLE O A nsn teni vietnam ieri mie EB eei mnt sens 28 3 2 4 Menu E oGk cient ELE teer EHI OA 28 3 2 5 Logon Logoff and Password t rettet Rp nanas 28 3 3 ALARMSSAND REPORTS2 ir etienne de enr E T vus ere tbe 29 3 3 1 Alarms ROTER 29 3 3 2 R DOFIS A us ee ce eh Rei EM RR Ce MERE e BEAR 32 3 4 ILET OPERA gue MC T 33 3 5 TEENETCONNEC LEIVITY cote te eae bee rte nv 34 3 6 EMBEDDED S NMP AGENT orent etit n E eo e rt e eet te ter e eee electo 34 3 7 MMBANDO MANAGEMENT SETUP deesset tee rte E ER e Eae veo Ea ve ed rese eter a Ey bere eer EE ed 35 MAINTENANCE 37 4 1 SELF TEST i live teer dev ep ra ei GR Ee ve eR iles envie rune D 37 4 2 DIAGNOSTICS RE NT RERO RAE RO 37 4 3 NEAR END LOOPBACK TC ent 37 4 4 FAR ENDISOOPBAGK M DEA eae 37 4 5
196. tware Version V8 17 03 07 20 2011 Device Name LOOP AM3440 C DISPLAY SETUP C gt System Configuration S System Setup gt Clock source Configuration M gt System Alarm Setup Q gt Alarm Queue Summary W Firmware Transfer Information Summary V gt Store Retrieve Configuration R Redundant CTRL Information K Clock source Setup P gt Performance Report T gt Bit Error Rate Test LOG MISC U gt Choose a Slot A gt Alarm Cut Off F gt Log Off SETUP MISC Menu X gt Clear Alarm Queue O gt Log On SETUP MISC Menu Y gt Controller Return to Default 2 gt Controller Reset gt gt SPACE bar to refresh or enter a command gt gt gt Input the unit number A D or 1 5 A If the password option is turned on a prompt asking for password is shown gt gt Enter password xxxx With the password option is turned on only after a valid password is entered the full menu is shown otherwise user is asked to enter the correct password again gt gt Invalid input of password Try again Y N If password is correctly entered or if the password option is OFF the full controller main menu is shown Otherwise only display menu items will be shown which are in the lower left half of the screen 6 1 Setup Display Chapter 6 Terminal Operation Menu Tree gt SNMP System Setup gt System B gt V1 Trap Setup S g
197. unction for all the AM3440 B devices must be set at 1 N Multicast This setting is highlighted on the sample setup screen below LOOP AM3440 C System Setup SYSTEM 14 59 03 12 12 2008 ARROW KEYS CURSOR MOVE Please Input hh mm ss mm dd yyyy BACKSPACE to edit System Time Date 14 59 03 12 12 2008 Device Name LOOP AM3440 C Network NI EN IPAddress SubnetMask Frame LB Timer LAN OFF 000 000 000 000 000 000 000 000 Ethernet WAN OFF 000 000 000 000 000 000 000 000 HDLC 00000001 Gateway Interface LAN Gateway IPAddr 000 000 000 000 CONSOLE port Baud Rate 38400 Stop Bit Bit Parity NONE XON XOFF XOFF TSI map Clock TSI Function 1 N Multicast Clock Mode SSM Idle Signalling 1010 lt lt Press ESC key to return to previous menu gt gt 172 Chapter 11 Appendix E Setting up an AM3440 C PDH Shared Protection Ring 7 Map Setup You must do your mapping for the Master Unit This is a sample TSI map for the Master unit The source port is Slot1 Port 3 and the target port is Slot1 port 1 LOOP AM3440 C System Setup MAP 14 59 31 12 12 2008 Please Input decimal number 1 32 BACKSPACE to edit MAP NO MAP 1 Target DTE A Source DTE A Target PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS PO TS D SL PO TS Slot 1 Port Pl Ld 3 17d 4 3 17 ld 17 d TS 01 2d 4 3 2 18d 4
198. up 2 Unit 24 Hour Perf Report S Unit System Setup A Unit Line Availability K gt Unit Clear Performance Data C Unit Configuration M Unit Alarm Setup gt Unit Status X gt Unit Clear Alarm Queue amp History H gt Unit Alarm History D gt Unit Upgrade Firmware Q gt Unit Alarm Queue LOG MISC U gt Choose Other Slot Y gt Unit Load Default Config P gt Choose Port Z gt Unit Reset F gt Log Off SETUP MISC Menu O gt Log On SETUP MISC Menu E gt Return to Controller Main Menu Reset are you sure Y N 147 Chapter 7 Appendix A Link Backup Function 7 Appendix A Link Backup Function 7 1 Introduction The Link Backup Function of AM3440 only applies to single E1 T1 FOM in mini slot A B C and D and 1FOMA in single slot 1 to 5 The Link backup function supports 1 1 and 1 1 protection This occurs when the system is set up so that a backup line or lines in the case of 1 n will be switched into service if the working line fails In such a case it must be switched in at each end of the line SUE Eo 2 menm 2 D 2 Plug in 2 ello Plug in 5 2 Plug in 1 Plug in 4 2 The illustration below is the Link Backup Function Schema Lil IN Daunuj Schema 1 1
199. uration to overwrite the current working configuration Please refer to the section 6 1 8 Store Retrieve Configuration for the detail operation The link backup configuration are the 1 1 and 1 1 protection schemes which only available in single E1 T1 FOM mini slot and 1FOMA single slot cards This occurs when the system is set up so that a backup line or lines in the case of 1 n will be switched into service if the working line fails Please refer to the section of Link Backup Function for the detail operation 2 4 2 Replacement of Plug in Card When a plug in card is removed and replaced with a card of a different type default configuration is assigned to the new card The user must set the configuration for each change of card type If the same type card is inserted depending on card type Chapter 2 Installation Table 2 8 V 35 DB25 DTE Port Pin Definition Pin Number Signal Transmit Data DTE DTE Clear To Send DCE Data Set Ready DCE DCE DCE DTE DCE DTE DCE DCE Remote Loopback DTE DCE ES 2 HRS INE gue NUM p e L ug En eee wer 02 NN 4 5 16 ONE RE uem 19 20 Sg mim 1 7 10 11 12 13 14 15 16 17 18 19 20 22 23 24 5 2 20 Chapter 2 Installation Table 2 9 V 36 EIA530 DB25 DTE Port Pin Definition 1 CableShield 7 6 Data Set Ready DCE 7 SignalGround 8 Data Carrier Detect
200. ure 6 1 AM3440 Controller Menu Tree Note PDH Ring Protection and PDH Ring Diagnositc are optional functions To access theses two optional functions you must order the controller card with PDH function to get the password for PDH setup Without the password these two functions will not show on the VT100 menu 41 Chapter 6 Terminal Operation 6 2 Main Menu If the terminal screen is illegible press the enter and esc key alternatively to bring up the main menu This is particularly needed if the terminal is connected to the controller while the power is already applied If the main menu still fails to appear check to see that the terminal is configured as 9600 8 n 1 and that a proper null modem or a null modem cable is used LOOP AM3440 C Controller Menu 15 14 57 09 09 2011 Set AD 0923 Serial Number 125618 Redundant Controller Disabled Hardware Version Ver H Start Time 15 11 27 09 09 2011 Software Version V8 17 03 07 20 2011 Device Name LOOP AM3440 C DISPLAY SETUP C System Configuration S gt System Setup gt Clock source Configuration gt System Alarm Setup Q gt Alarm Queue Summary W Firmware Transfer gt Information Summary V gt Store Retrieve Configuration R Redundant CTRL Information K Clock source Setup P gt Performance Report T gt Bit Error Rate Test LOG MISC U gt Choose a Slot A gt Alarm Cut Off F gt Log Off SETUP
201. uspect Note that this is not definitive as other reasons may cause the same symptom A good practice is to reconfigure the original one and swap once more If both units behave the same then the problem is probably elsewhere 4 6 3 Using Loopback Plugs Without a spare loopback plugs are handy for diagnosis Note that internal loopback facilities of the Loop AM3440 does not include the interface circuitry Thus a set of plugs one for each of the interfaces line and DTE are needed for complete tests These plugs are wired such that signals from the Loop AM3440 are loopback by hard wire back to the receive pin of the same plug Replace the line connector with a loopback plug Observe if the line is in sync If not then Loop AM3440 has failed Then perform a PRBS test towards the line If this fails then Loop AM has failed Note that if a far end terminal is available the first test should be a local line loopback to see if the line is good If tests with loopback plugs all pass then the problem is probably elsewhere 4 6 4 Using Bert Test Set If a BERT bit error rate test set and another Loop AM3440 are available such as the Fireberd 6000 then a comprehensive suite of test are available to examine the health of the Loop AM3440 If another Loop AM3440 is not available use of the loopback plugs would provide some of the tests otherwise possible With a BERT each of the ports of the Loop AM3440 can be tested individually The user mu
202. verrun 1005 tdmoe eth 1 link down 1006 tdmoe eth2 link down 1007 tdmoe eth3 link down 1008 tdmoe eth4 link down 1009 168 Alarm type LOS OOS SES UAS LOOPBK TEST LOF Alarm type LAN1 LAN2 Alarm type LAN1 LINK DOWN LAN2 LINK DOWN Alarm type LAN1 LINK DOWN LAN2 LINK DOWN LAN3 LINK DOWN LAN4 LINK DOWN LAN5 LINK DOWN LAN6 LINK DOWN LAN7 LINK DOWN LAN8 LINK DOWN Alarm type ARP LOST RX LOST CELL LOST UNDERRUN OVERRUN ETH1 LINK DOWN ETH2 LINK DOWN ETH3 LINK DOWN ETH4 LINK DOWN Chapter 10 Appendix D LOOP AM3440 C ALARM TRAP INFORMATION 10 7 Alarm Setup Indication Access M System Alarm Setup from the VT100 main menu to activate the alarm actions listed below dup he N M N M 254 254 Alarm Setup Alarm Action for type slot port Alarm Cut Off Alarm cut off Slot Inactive Slot N inactive N inactive Slot Startup Slot Startup Slot N E Slot N P M clock loss External clock loss Master Clock Slot N Pm Loss 103 Clock Loss Second Clock Slot N Loss 104 CTRL1 2 EXT clock loss 105 CTRL1 2 redundant EXT clock loss Em SSM switch to Slot SSM ioral sofa TT Link switch to 6 QE1 1 1 Link Switch Link switch to QE1 1 1 unum PDH DSO SNCP switch to oe eae switch to Switch Switch Map switch to m14 m14 4 Power fail alarm A3 C3 Power Alarm Fan fail a
203. y n slave mode as protection function IS enable 4 LEDs DTE port Flashing Green Transmit Receive data present V 35 V 36 Green Normal EIA530 Flashing Green regularly Loopback Test RED Alarm X 21 V 11 E1 T1 line frame in sync E1 T1 line is under testing Loss of Frame LOF or Loss of Signal LOS Receive yellow alarm from E1 T1 line Receive alarm indication signal AIS from E1 T1 line Green Flash Green Red Amber Flashing Amber 33 Chapter 3 Operation 3 5 Telnet Connectivity To manage the system from internet Loop AM controller offers Telnet connectivity and SSH Secure Shell to allow user access to the Loop AM controller from any workstation in the network SSH Secure Shell is a network protocol that allows data to be exchanged over a secure channel between two computers Encryption provides confidentiality and integrity of data SSH uses public key cryptography to authenticate the remote computer and allow the remote computer to authenticate the user if necessary There are two interfaces for Telnet function one is Ethernet port and the other is in band port in band management To use Ethernet interface use Ethernet RJ45 port at back panel to connect with Ethernet network directly Ethernet and in band port cannot be used at the same time To use the Telnet function make sure IP Address and Interface parameters are ma
204. z OdBm input 0 25 to 1 dB from 300 to 3400 Hz Nominal 48 Vdc with 25mA current limit per port 1 REN at 5000 meters per port 20 Hz other frequencies manufacture option 16 7 Hz 25 Hz 50 Hz 76 Vrms sine wave User selectable ring cadence per card for PLAR function 2 sec on 4 sec off or 1 sec on 2 sec off Ringing REN 0 5B AC Detectable Ringing 25 Vrms Loop Resistance lt 1800 Q DC impedance ON HOOK gt 1MQ DC impedance OFF HOOK 235 Q 25mA feed 90 100mA feed 12 KHz 16 KHz Power 10dBm Sensitivity 18dBm to 45dBm manufacture option Loop Start GND Start Metering Pulse 12 KHz 16 KHz DTMF Dialing Pulse PLAR Battery Reverse support Line Reverse Signaling for Billing transparent Voice Card 12 5 12 24 5 24 12 FXS FXO Connector 24 FXS FXO Connector Alarm Conditioning Encoding AC Impedance Longitudinal Conversion Loss Cross talk measure Gain Adjustment Signal Distortion Frequency Response Idle Channel Noise Variation of Gain FXO FXS Loop Feed FXS signalling FXS Ringing Signaling Optional Signaling for special order Signaling Bit A B C D Twelve RJ11 One RJ21X Female CGA busy after 2 5 seconds of LOS LOF A law or p law user selectable together for all Balanced 600 or 900 ohms selectable together for all gt 46dB Max 70dBm0 21 to 10 dB 0 1dB step transmit amp receive gt 25dB with 1004 Hz OdBm input 0 25 to 1 dB from 300 t

Download Pdf Manuals

image

Related Search

Related Contents

  Lecteurs DVD DVP  Model 125-I User Manual  Instrucciones de Operación - Rice Lake Weighing Systems  Emerson 1305 Series Pressure Reducing Regulators Instruction Manual  Door Stop Alarm User Manual  user manual digipass 270  HDVS IP CAMERA SI20 & SE20 User Manual  Conditions générales du contrat DILIZI  Manuale Utente  