Contents

1. 1057714 JP 3686609 NZ 513052 NZ 526165 NZ 526166 NZ 526167 NZ 526168 US 6112746 US 6119693 US 6357441 US 6374826 US 6439230 US 6463931 US 6532961 US 6557556 US 6581594 US 6581602 US 6634358 US 6691708 US 6823865 US 6860269 US 6871649 US 6997188 US 7011090 US 7159587 US 7178527 US 7188620 US 7216647 US 7234466 US 7243651 Other patents pending Protected by design registrations AU 304309 CN 200530117106 1 EP 366844 JP 1264474 NZ 406357 US D532512 US D547438 US D545960 Others pending AutoSet CS Mirage and Mirage Micro are trademarks of ResMed Ltd AutoSet CS and Mirage are registered in U S Patent and Trademark Office Velcro is a registered trademark of Velcro Industries B V 2008 ResMed Ltd 618114 Eng 1 0809 MIRAGE MICRO USER EHE TM TT AMER MULTI Brett Global leaders in sleep and respiratory medicine www resmed com
2. of the mask and may cause the components to crack or break Daily After Each Use To optimize the mask seal facial oils should be removed from the cushion before use Handwash the mask by gently rubbing in warm 86 F 30 C water using mild soap If the vent requires cleaning use a soft bristle brush Rinse all components well with drinking quality water and allow them to air dry out of direct sunlight Do not soak the mask Weekly Handwash the headgear in warm approx 86 F 30 C water using mild soap Reprocessing the Mask between Patients This mask should be reprocessed when used between patients Cleaning disinfection and sterilisation instructions are available from the ResMed website www resmed com masks sterilization americas If you do not have Internet access please contact your ResMed representative English Reassembling the Mask nsert the ports cap Insert the cushion into the mask frame Ensure that he arrows at base of the cushion and mask frame are aligned 4 t amp MM Push the forehead pads firmly into the forehead support gt t 1 D Li CJ M A nsert the forehead support a into the mask frame and screw b the dial clockwise onto the pole Turn the dial until it clicks c Ensure the dial sits flush against the rame nsert the assembled Reattach the top headgear elbow into the mask frame
3. 1 LW 16392 XL Mask frame 16395 S 16394 St Elbow 2 16387 Headgear clip DI 16569 2 16734 10 Ports cap Swivel 16570 2 16565 J 16571 10 Headgear 16118 S 16117 M 16119 L S Small M Medium L Large LW Large Wide XL Extra Large St Standard 2 Fitting the Mask Turn the dial so that the orehead support is fully extended Hold the mask over your nose and pull the headgear over your head Bringing the lower straps below your ears connect he headgear clip to the the mask frame 5 A V J cu EOS fo e O Unfasten the Velcro pull the upper headgear straps evenly until they are comfortable and firm and reattach the Velcro Repeat step 4 with the ower headgear straps Connect the main air tubing to the swivel Then connect the free end of the air tubing to your flow generator and turn the flow generator on Lie down in your sleeping position Adjust the dial until the mask is evenly positioned on your face It should be comfortable with a satisfactory seal Adjust the headgear straps if necessary The fitted mask is shown above Removing the Mask Disconnect one of the headgear clips and pull the mask and headgear up over your head English Disassembling the Ma
4. RESMED Mirage Micro NASAL MASK User Guide English RESMED Mirage Micro NASAL MASK Thank you for choosing the Mirage Micro M Intended Use The Mirage Micro channels airflow noninvasively to a patient from a positive airway pressure device such as a continuous positive airway pressure CPAP or bilevel system The Mirage Micro is e to be used by adult patients gt 66 Ib 30 kg for whom positive airway pressure has been prescribed e intended for single patient re use in the home environment and multipatient re use in the hospital institutional environment Rx Only Before Using the Mask A WARNINGS e The vent holes must be kept clear e The mask should not be used unless the CPAP system is turned on and operating properly e Follow all precautions when using supplemental oxygen e Oxygen flow must be turned off when the flow generator is not operating so that unused oxygen does not accumulate within the flow generator enclosure and create a risk of fire e Ata fixed flow rate of supplemental oxygen flow the inhaled oxygen concentration varies depending on the pressure settings patient breathing pattern mask point of application and leak rate e The technical specifications of the mask are provided for your clinician to check that they are compatible with the flow generator If used outside specification or if used with incompatible devices the seal and comfort of the mask may not be effect
5. ents tor Lot number REF Part number 4 Temperature limitation S Humidity limitation Does not contain latex A Indicates a Warning or Caution and alerts you to a possible injury or explains special measures for the safe and effective use of the device English Limited Warranty ResMed warrants that your ResMed mask system including its components mask frame cushion headgear tubing and other accessories Product shall be free from defects in material and workmanship for a period of ninety 90 days from the date of purchase by the initial consumer For further details refer to the Warranty Technical Specifications Note The mask system does not contain latex PVC or DEHP materials Pressure Flow The mask contains passive venting to protect Curve against rebreathing As a result of manufacturing variations the vent flow rate may vary so Pressure Flow Da cm H O L min g 5 i 4 19 Es 8 28 oc 3 12 34 5 g 16 40 E 8 10 n EI 16 18 20 45 Mask Pressure cm H 0 Dead Space The dead space of the mask varies according to cushion size It is Information 128 mL for the Extra Large size Therapy Pressure 4 to 20cm H O Resistance Drop in pressure measured nominal at 50 L min 0 1 cm H O at 100 L min 0 7 cm H O Environmental Operating temperature 41 F to 104 F 5 C to 40 C Conditions Operating
6. humidity up to 9596 non condensing Storage and transport temperature 4 F to 140 F 20 C to 60 C Storage and transport humidity up to 95 non condensing Gross Si 140 mm H x 91 mm W x 93 mm D dimensions L LW XL 155 mm H x 91 mm W x 98 mm D ask fully assembled no headgear Note The manufacturer reserves the right to change these specifications without notice Storage Ensure that the mask is thoroughly clean and dry before storing it for any length of time Store the mask in a cool dry place out of direct sunlight Disposal The Mirage Micro does not contain any hazardous substances and may be disposed of with your normal household refuse 8 ResMed Ltd Manufacturer 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp US Designated Agent 14040 Danielson Street Poway CA 92064 6857 USA ResMed UK Ltd EU Authorised Representative 96 Milton Park Abingdon Oxfordshire 0X14 4RY UK ResMed Offices Australia Austria Belgium Brazil China Finland France Germany Greece Hong Kong India Ireland Italy Japan Malaysia Mexico Netherlands New Zealand Norway Portugal Singapore South Africa Spain Sweden Switzerland UK USA see www resmed com for contact details Mirage Micro Nasal Mask Protected by patents AU 710733 AU 741003 AU 766623 AU 775051 AU 777033 AU 785376 CA 2261790 EP 0956069 EP 1187647 EP 1187648 EP 1187649 EP 1187650 EP 1314445 EP 1479406 HK
7. ive optimum therapy may not be achieved and leak or variation in the rate of leak may affect the flow generator function e Discontinue using the Mirage Micro if you have ANY adverse reaction to the use of the mask and consult your physician or sleep therapist e Using a mask may cause tooth gum or jaw soreness or aggravate an existing dental condition If symptoms occur consult your physician or dentist e As with all masks some rebreathing may occur at low CPAP pressures 1 English e Refer to your flow generator manual for details on settings and operational information Flow Generator Settings Select Standard or Vista for VPAP Adapt SV as the mask option when using the Mirage Micro with ResMed flow generators that have mask setting options For a full list of compatible devices for this mask see the Mask Device Compatibility List on www resmed com on the Products page under Service amp Support If you do not have internet access please contact your ResMed representative Parts of the Mask amp Ordering Information Complete system S 16333 M amp L 16334 LW amp XL 16335 Frame system no headgear S 16378 M 16379 L 16380 LW 16381 XL 16382 Frame assembly no headgear no cushion S 16383 St 16384 Elbow assembly elbow swivel Forehead 16399 support pad 60123 1 Forehead rt orehead suppo 60124 10 16393 Mask cushion 16388 S 16389 M 16390 L 1639
8. sk Detach the air tubing Unclip the headgear clips Remove the elbow and unthread the upper assembly from the mask headgear straps It is not frame by pivoting from the necessary to remove the bottom edge headgear clips from the headgear Remove the swivel from he elbow ote the position on the dial for the next time you use he mask Unscrew and remove the dial a then pull the orehead support b out of the mask frame Remove the forehead support pads from the forehead support Remove the cushion Remove the ports cap rom the mask frame rom the mask frame Cleaning the Mask at Home Notes e The mask and headgear should be cleaned by handwashing e The headgear may be washed without removing the headgear clips Ah WARNING Do not use aromatic based solutions or scented oils eg eucalyptus or essential oils bleach alcohol or products that smell strongly eg citrus to clean any of the mask components Residual vapours from these solutions can be inhaled if not rinsed thoroughly They may also damage the mask causing cracks A CAUTION e If any visible deterioration of a mask component is apparent cracking crazing tears etc the mask component should be discarded and replaced e Avoid connecting flexible PVC products eg PVC tubing directly to any part of this mask Flexible PVC contains elements that can be detrimental to the materials
9. straps by threading them hrough the loops nsert the swivel into the end of the elbow Troubleshooting Problem Mask won t seal properly or is uncomfortable Possible reason Mask may have been fitted incorrectly or is incorrectly adjusted Mask is wrong size Mask cushion is skewed in mask frame Mask cushion is misaligned or creased on face Mask cushion may be dirty Possible solution Carefully follow instructions in Fitting the Mask Check headgear and dial are not over tightened Extend dial to apply more force to upper lip Shorten dial to increase force at nose bridge Talk to your clinician Check insertion of cushion and reinsert correctly according to the instructions in Reassembling the Mask Ensure cushion is properly aligned according to the instructions in Reassembling the Mask Make sure the cushion has no creases in it undo headgear clip check cushion and reposition the mask over your nose Clean cushion according to nstructions in Cleaning the ask at Home Mask is too noisy Mask is assembled incorrectly Vents are blocked or partially blocked Reassemble mask Clean vents according to nstructions in Cleaning the ask at Home Dial inserted into mask frame before forehead support Misassembly Push dial base onto a hard surface until the dial comes out of the frame Symbols A Caution consult accompanying docum