Digital Systems Software Requirements Guidelines

image

Contents

1. 37 A temperamental altimeter A good many problems due to the design of certain systems have revealed themselves since the start of operation The most spectacular for the passengers would have been the vagaries of the integrated cabin communication system CIDS which modified explanations or illuminating announcements in an eccentric fashion More seriously the crews discovered that the temperature regulation of the passenger cabin could interfere with the functioning of the engine power control computers FADEC generating breakdowns and alarms To avoid these interferences crews were asked not to reinitialise the cabin temperature regulation system while the engines were running However the most worrying phenomenon for the crews has been the untimely alterations to the setting of the altimeters during flight Having reached a certain altitude the pilots set their altimeters in a standard way calculated in relation to the theoretical atmospheric pressure at sea level 1 013 hPa in order that all aircraft using the airspace should have the same reference for altitude QNH base Relative to this base the altimeter indicates a pressure altitude which is a QNE altitude While the aircraft is descending at a predetermined height the crew must set their altimeters in relation to the altitude of the destination airport QFE base Apart from some very rare landing strips situated below sea level airports are above this sea l
2. Discussion Robustness requirements must address the potential of hardware failures due to design or other sources Growing complexity of hardware makes such design failures increasingly likely Provisions for tolerating hardware failures are incorporated in Guideline 2 5 2 1 16 0009 Train Door Failure Date 01 08 00 Source Risks 21 04 Neumann 2001 Domain Ground transportation Function Door control Guidelines 2 5 2 3 2 1 1 Description Bruised but still a believer the train fan who became a victim Date 01 08 2000 By ROBERT WAINWRIGHT Transport Writer As the head of Planet Ark John Dee sat on the Olympic bid committee which proclaimed that spectators should be encouraged to use public transport As a commuter Mr Dee almost became a victim of the system he supported when his leg became trapped in a train door as it left Meadowbank Station on Sunday afternoon Though his pro public transport beliefs have not changed Mr Dee nursing a badly bruised right leg and sprained back was having second thoughts yesterday about safety levels of the beleaguered rail system He was the second person in the past four days to be trapped in a train door Last Thursday an elderly woman was trapped in the door as a train traveled between Redfern and Erskineville The official report said the woman s leg was still protruding from the door when the train arrived at the next station Mr Dee s ordeal began when he was returning home to Ki
3. 0034 Snubber Inspection Scheduling 0 0 cece ee eee eae 55 0035 Reactor Instrumental 56 0056 Inspection Procedures 200000 AA AAA A A ERAS 57 0037 Disabled ATatHi IA RA hg gt bel 58 0038 Incomplete Surveillance Software llle 59 0039 Monitor Accuracy Error vs vercion da GRE ERG REPAS 60 0040 Deficient Surveillance Test Procedure 2 0 cece ee eee eee 61 0041 Software Maintenance Problem 0 0 cece eee eee eee eae 62 0042 Missed surveillance TE A HACER Sea he ERE 63 0045 Date Uncertainty s es a Sey cs XE EE ENDE S UEM RN E NE A 64 0044 Rod Position Calculation 0 ee eee ene ne eas 65 0045 Reactor Power Calculation 52e eee aye oad ao 66 References cus pep dan a AAA ARM NN RB URN A RN EA RICE RN 67 List of Tables Table 2 1 Failure Reports to Guidelines Vol 1 Cross Reference oooooooooommo mo Table 2 2 Guidelines Vol 1 to Failure Reports Cross Reference ooooooooooooooomo Executive Summary A significant proportion 1f not the majority of all accidents in which software was involved can be traced to requirements errors Not only do missing inaccurate or incomplete requirements lead to flaws in software development they also prevent these flaws from being detected during V amp V For example functional testing is based on the requirements a missing or inaccurate requirement will therefore not be detected Integration testing sometimes detects the omissions or i
4. Description On July 16 1998 as part of Oconee s Recovery Plan for Technical Specification TS Initiative it was recognized that some TS snubber surveillances were incorrectly coded in the scheduling software On July 22 1998 with Units 1 2 and 3 at 100 full power a review of past snubber surveillance dates on all three units determined that Unit 2 had exceeded the snubber surveillance frequency from approximately February 13 1998 until the unit was shutdown for a refueling outage on March 13 1998 The surveillance was satisfactorily completed on March 18 1998 The root cause of this event is a weak process to control changes to the frequency in the scheduling software A contributing cause is the potentially confusing wording of several TSs Discussion Scheduling software is part of the offline monitoring functions Guideline 2 6 3 for these functions states Requirements should specify for each of the system surveillance and monitoring operations The frequency of execution of the offline monitoring functions by sensor or channel if applicable 55 0035 Reactor Instrumentation Date 3 20 99 Source LER 275 1999 002 Domain Nuclear power Function Power and temperature instrumentation Guidelines 2 5 1 1 Description On March 20 1999 at 1753 PST with Unit 1 in Mode 1 Power Operation at 92 percent power Technical Specification 3 3 1 Reactor Trip System Instrumentation Table 3 3 1 Action 6 was not met whe
5. Domain Train control Function MMI Guidelines 2 1 3 2 5 2 3 Description Pete Mellor lt pm cs city ac uk gt Mon 23 Jul 90 20 00 44 PDT gt From the Guardian Mon 23rd July front page Headline BR signalmen worked blind Subhead Computer software problems admitted at key commuter train center By line Patrick Donovan Transport Editor British Rail has admitted that computer software problems have been uncovered at a signal center which controls London s busiest commuter lines They left operators working blind after train movements were wiped off control screens on at least one occasion over the last five weeks A BR spokesman said newly installed software responsible for flashing up the position of trains on the indicator screens of signal operators at Wimbledon has been found to contain two technical faults The Wimbledon center controls 90 mph services south of Waterloo and includes the Clapham Junction area where 35 people died in a train accident in December 1988 Faulty wiring on a signaling modernization program was found to have caused the crash BR said one of the faults uncovered on the indicator screen software has not yet been fully rectified An internal investigation began after an operator found that the system was providing the wrong information Realizing that he had lost track of train movements the operator immediately turned all signals to red A spokesman said that at no time was any train at
6. at http www theregister co uk content 1 12287 html and Andrew Brydon in a BBC item that mentioned seven complaints PGN Discussion The upgrade requirements failed to provide the assurance of access control that had existed previously This cause of failure is classified as an example of lack of access control Guideline 2 7 2 The failure description also indicates that requirements did not provide a defined methodology for performing software upgrades we will not relaunch until totally confident this cannot happen again This cause of failure is classified as an example of lack of upgrade support Guideline 2 6 5 19 0011 Elevator Software Date 11 12 98 Source Risks 20 07 Neumann 2001 Domain Elevator Function Floor announce Guidelines 2 6 6 Description Talking elevator with off by one error George Michaelson lt ggm dstc edu au gt Thursday 12 November 1998 11 19 10 1000 EST New building Seven floors labeled 1 7 Enter lift elevator Select floor 1 Arrive at floor 1 Lift announces Floor eight My guess is that the software is generic and is loosely coupled to the real I know where I am function the lift has innately talking or not I have a mild concern that a lift this is confused maybe doesn t want to be used Shades of Douglas Adams George Discussion The software requirements for interfacing with the real world were issued and not verified This cause of
7. failure is classified as an example of lack of failure rate calculation and assessment of conformance with quantitative requirements Guideline 2 4 5 26 0018 Weather Processor Crash Date 11 14 00 Source AMBRIEFS FAA 2000 Domain Air traffic control Function Weather processing systems Guidelines 2 6 1 2 5 2 7 Description DETAILS At 3 00 P M EST the Aviation Weather Processor Service AWPS was interrupted due to a system trap out All users were transferred to Salt Lake City SLC at 3 15PM RESOLUTION Specialists performed a software reload and completed a flight database rebuild to restore service At 4 42 P M the users were transitioned back to Atlanta AWPS UPDATE 1114 0217Z Service A transmit process SATO trap out occurred due to a process invalid condition in CPU 0 The preliminary examination of the save files by Operational Support AOS revealed that the trap out occurred while attempting to transmit the non hourly weather reports to WMSCR when the non hourly portion of the service A transmit queue became full Atlanta AWP was requested to submit a PTR and forward the save files on tape and the service A line monitor system history file to AOS 540 for further analysis No change in AWP procedures has been recommended at this time Discussion Diagnostics in this case supported timely restoration of service Although not a cause of failure the event emphasizes the need for offli
8. in order to correct defects in the systems or to enhance them has been the origin of new breakdowns These new problems have obliged the manufacturer to publish new OEDs before drawing up final modifications During service companies have had to modify certain procedures once or several times for operating their aircraft Also with the exception of Air Inter which reported only good results the increased number of incidents was the origin of poor availability and bad technical readiness of the first A320s delivered Of 7 334 stopovers landing take off s carried out up to April 1989 states the report of the technical sub director of Air France one lists on technical grounds i e something went wrong 4 acceleration stops on take off 36 about turns on the ground 10 about turns in the air 1 36 emergency descent procedure the cabin altitude being on the increase without violent decompression 1 engine stop in flight I think an about turn on the ground is an aborted take off and an about turn in the air is a return to the departure port I m not sure what the difference is between an about turn on the ground and an acceleration stop Presumably the latter means the engines raced or cut out during approach to take off Cabin altitude being on the increase is a literal translation I think it means the cabin atmosphere was below pressure since they came down Anyone with access to a dictionary of French av
9. notified this to the appropriate vendor which confirmed the bug with us and told us that it would soon be fixed Added note The bug with the PC software was so huge it looks like it only happens with our setup the vendor claims it is the first time it happened that what we have is the AC units running continuously no matter what the thermostat tells the control unit Discussion The vendor had used this program previously It only happens with our set up and assumed it to be suitable for a wide range of environments This assumption was clearly incorrect and would have been discarded if a complete specification of the run time environment had been generated This cause for the failure is classified as an inadequate specification of the complete run time environment Guideline 2 3 1 1 The description indicates that neither the software nor the system had been adequately tested prior to being put into operation This cause of the failure is classified as an example of inadequate online checks of pre developed software intended for multiple system configurations Guideline 2 6 1 0002 Decimalization and Ford Stock Splits Date 08 07 00 Source Risks 21 05 Neumann 2001 Domain Financial Function Guidelines 2 1 3 2 2 1 3 Description On 7 Aug 2000 Ford completed its Value Enhancement Plan a somewhat complicated stock transaction where Ford created a new company Ford Value Company and issued a new stock Ford stockholder
10. of SP 1016 12 RCP tripped and the 11 Turbine Driven Auxiliary Feedwater Pump TDAFWP auto started This event was reported via the Emergency Notification System on the basis of entry in PINGP Technical Specification 3 0 C due to loss of both RCPs and on the basis of ESF actuation of the 11 TDAFWP SP 1016 and corresponding Unit 2 SP 2016 will remain quarantined until the procedures are appropriately revised A step to lift a wire that was in a previous revision of SP 1016 would have prevented trip of the 12 RCP The missing step in the SP was apparently due to an electronic document management system EDMS software error when the SP 1016 file was converted to the new EDMS system in 1996 The loss of the SP step upon conversion was not identified during post typing or engineer review Discussion The surveillance procedure requirements apparently contained no provision to assure that all required functions were present Functional completeness of software requirements Guideline 2 3 1 4 Surveillance procedure software is part of the offline monitoring functions Guideline 2 6 3 for these functions states Requirements should specify for each of the system surveillance and monitoring operations Interlocks to prevent operation when systems are being maintained 57 0037 Disabled Alarm Date 1 18 99 Source LER 302 1999 001 Domain Nuclear power Function Control rod alarm Guidelines 2 1 1 Description On January 18 1999 Florid
11. requirements for tolerating sensor failure This cause of failure is classified as an example of lack of requirements for handling input output hardware failures Guideline 2 5 2 1 That forcing a door open will cause an emergency stop that can only be manually reset by train personnel indicates a need to review requirements for response to temporary conditions This cause of potential failures is classified as an example of cancellation of partially completed operations Guideline 2 5 3 3 The description indicates that people can be trapped in partially open doors and that the response to such events is up to the individual operator Proper requirements would identify a response to such situations This cause of potential failures is classified as an example of response to events Guideline 2 9 2 48 0029 London Subway Doors Date 1 10 91 Source Risks 10 77 Neumann 2001 Domain Ground transportation Function Automatic doors Guidelines 2 1 1 2 5 3 3 2 9 2 Description Vicious Doors on London Underground Network South East Pete Mellor lt pm cs city ac uk gt Thu 10 Jan 91 21 33 56 PST I was interested in Olivier M J Crepin Leblond s two mailings RISKS 10 75 regarding the recent train crash and the behavior of tube train doors I am also a victim sorry commuter of Network South East the bit of what used to be British Rail that serves East Anglia and the area southeast of London They are a byword for discomfor
12. shut down according to Flight This may be a reference to the earlier reports of spurious signals from flap and gear sensors reported in an earlier RISKS Flight International adds that a FADEC failure is extremely unusual Martyn Thomas Chairman Praxis plc Software Engineers Discussion Sensor failure caused engine shutdown in a critical flight regime Requirements for redundant sensors and data processing would have avoided the problem This cause of failure is classified as an example of validity checks on input Guideline 2 5 2 3 51 0031 Security Computer Failure Date 1 14 98 Source LER 206 1998 001 Domain Nuclear Power Function Security Computer Guidelines 2 3 2 2 2 5 2 3 Description On January 14 1998 discovery date Southern California Edison SCE prepared to install a chart recorder on the primary security computer for system diagnostic testing At about 9 25 A M before starting the installation SCE had conservatively posted compensatory guards for the appropriate plant areas as specified in Station Procedures SO123 IV 6 8 Protected Area and Vital Area Barrier Patrols for a complete loss of security computers SCE switched to the backup security computer removed the primary computer from service and installed the chart recorder When returning the primary computer to service a computer network server software error occurred causing the primary computer to initialize incorrectly At about 10 26 A M the ba
13. Digital Systems Software Requirements Guidelines Vol 2 Failure Descriptions Contract RES 00 037 M Hecht H Hecht SoHaR Incorporated Beverly Hills CA for Nuclear Regulatory Commission Washington DC June 2001 Abstract This document provides descriptions of 45 failures that are linked to software requirements review guidelines listed in Volume I prepared under Contract NRC 00 037 The failure descriptions are lessons learned which illustrate why the specific software requirements guidelines are needed Iv DMA ts EA A e s iii Sto ADS oasis DT vil Executive Summary eri a ld da viii ACTONYINS vi eda e erae p a ex AR CR REA EY ha Ua e A D S ACRES ix 1 Frtrodue ETO osa ia a e oe o eN toa dU a oe 1 2 Overview of Failure Descriptions eese es ede ee he eg AO E Aa 2 3 Failure DescripHODs 2 24 hse seat a Roce eases A A 7 0001 Configuration Management on User Interface 02 2 eee eee eee 8 0002 Decimalization and Ford Stock Splits 2 0 2 eee ee nee 9 0003 Pentagon Security Gate Malfunction 0 0 0 0 cece eee ee eee 10 0004 Single Points of Failure and Inadequate Backup Plans o oo omooo o 11 0005 UPS Backup Failures jo 2s aes 3 ag Mow view eed sais 12 0006 Saturn Limit Logic e dea a ne AS dd dd 14 0007 A Subtle Pence post Error lt a A 15 0008 Pentium HE Chip Flaw pida ae ale Ad ed 16 0009 Train Door Failure 00 RR Er Rr RIDERS ae eae ea a ees 17 0010 Failures During Upgra
14. In plain terms this message informed the pilots that the controls activating the pitch control mechanism were no longer in a functional state In this case the only means of ensuring the longitudinal stability of the aircraft is to manually move the trimmable horizontal stabilizer by means of the pitch trim wheels Meanwhile the copilot who was at the controls felt not the slightest difficulty in controlling the aircraft Then the crew witnessed a display of imaginary alarms fire in the toilets for example and noticed new signaling anomalies on the screens concerning the flight control systems the position of the landing gear and also the situation of the automatic pilot It was therefore decided to return but during the approach the gear at first refused to come down normally Given the uncertainty three passes at low altitude were made in front of the control tower to ascertain the real position of the gear after having carried out safety maneuvers As the information provided to the crew gear partially down did not correspond to the observations of the controllers at Roissy gear down the passenger cabin was prepared for an eventual crash which very fortunately did not occur The same incident recurred on another plane on 29th November 1988 It finally required nine months of operation before a new more reliable version of the Flight Warning Computer FWC called into question by these two cases was made available to users
15. SES DE NERFS DE L A320 Translation of article by Bertrand Bonneau THE A320 S ATTACKS OF NERVES The first aircraft in the history of the world to be totally managed by computer Has the A320 been put into service before it is ready The excessive number of incidents during its first year of use can only make one think so How could the willingness to declare the pilots responsible for major accidents even before the judges have returned their verdict appear other than suspect Even so as everyone wished the verdict whitewashed the aircraft At the start of 1988 the French authorities and Airbus Industries congratulated themselves on the certification of the A320 only one year after the first flight of the prototype In less than one year the manufacturer had demonstrated the reliability of this new generation aircraft to the authorities of four of the states of the European Community However controversy surrounding the aircraft would not be slow to surface at the time of the inaugural flight of the Air France A320 on 28th March 1988 over Paris with the Prime Minister of the time on board This flight was marked by a series of technical incidents notably by the untimely setting off of alarms New controversies were to arise when an aircraft was destroyed in the forest of Habsheim in Alsace 26th June 1988 and when an Indian Airlines A320 crashed before reaching the runway in Bangalore last February In both of the last two cas
16. This cause of failure is classified as an example of inadequate correctness requirements Guideline 2 1 3 That the software furnished wrong information to the operator indicates lack of requirements for internal checks This contribution to the failure is classified as an example of failure to provide for validation of inputs and outputs Guideline 2 5 2 3 44 0027 NASDAQ Outage Date 12 1 00 Source Copeland 2000 Domain Stock trading Function Online trading system Guidelines 2 4 6 Description Software glitch forces 11 minute shutdown of NASDAQ By Lee Copeland Computerworld http www infoworld com articles hn xml 00 12 01 001201hmnasdag xml p br8s 7 1207thpm A SOFTWARE GLITCH in the NASDAQ s price quote engine caused the stock exchange to halt trading for 11 minutes on Wednesday It is the third time this year that the stock exchange has experienced a slowdown or halt in trading due to problems with its order routing system Analysts said temporary outages and technology glitches are recurrent problems that online brokerages and trade exchanges haven t yet been able to lick NASDAQ will have glitches as will NYSE and other full service and online brokerages because no one is operating in a fail safe mode said Dan Burke an analyst at Gomez Advisors in Lincoln Mass They are all spending tremendous amounts of resources to ensure 100 percent uptime but there s no real way to ensure it yet According to NASDAQ stock mark
17. a Power Corporation s FPC Crystal River Unit 3 CR 3 was in MODE 1 Power Operation at 99 9 percent Rated Thermal Power RTP FPC personnel discovered that a Surveillance Requirement SR had not been performed within the time specified in Improved Technical Specifications ITS when a regulating control rod computer alarm became inoperable without operator knowledge ITS SR 3 2 1 2 requires verification that the regulating rod group position meet the insertion limits specified in the Core Operating Limit Report COLR once every 12 hours when the regulating rod insertion limit alarm is operable and once every 4 hours when the regulating rod insertion limit alarm is inoperable FPC determined that the rod insertion limit alarm on the plant computer was bypassed for power below 1596 RTP Plant procedures did not reflect that the rod insertion limit alarm is inoperable below 1596 RTP and did not require the increased surveillance frequency of once per 4 hours Currently a Plant Integrated Computer System PICS is being installed to replace the ModComp During testing of alarm software for the PICS it was determined that the rod index alarm quadrant power tilt alarm and axial power imbalance alarm were bypassed below 1596 RTP This was discovered due to the more extensive testing of alarm software for the PICS than had been performed on the ModComp It was subsequently found that this same bypass existed in the operating ModComp software Discuss
18. agement decision making and to help in the evaluation of fixes e g Did a corrective measure reduce the failure rate This contribution to the failure is classified as an example of lack of failure rate calculation and assessment of conformance with quantitative requirements Guideline 2 4 5 23 0015 TDWR Communication Failure Date 11 18 00 Source AMBRIEFS FAA 2000 Domain Air traffic control Function Weather radar Guidelines 2 5 1 1 2 5 1 2 Description DETAILS On 11 18 at 9 11 PM MST the Terminal Doppler Weather Radar Service TDWRS failed inclear weather due to a communications problem The Wind Measuring Equipment WME was available RESOLUTION MCI Worldcom investigated under ticket 41119 0210 and reported that numerous channel banks were interrupted when a contractor caused a flood in the U S West main central office in Salt Lake City Telco restored the circuit using an alternate path and the service was restored on 11 19 at 2 05 A M Discussion The long recovery time was partially due to lack of requirements for dealing with anomalous conditions Manual switchover to alternate commercial lines or satellite communications would have reduced the outage time This cause of the outage is classified as an example of lack of requirements for error handling Guideline 2 5 1 Also redundant communication channels shared a single weak link The requirements should have called for identification and avoidance of correlated
19. al Specifications TS surveillance period with the applicable TS action not being met Operations personnel were notified and the ST procedure was satisfactorily completed on 06 29 98 A weakness exists in the use of the ST scheduling software program 1 e Primavera P3 The program is utilized differently for STs having weekly frequencies Specifically the automatic updating interface process between the Plant Information Management System PIMS and Primavera is bypassed to accommodate the shorter window for processing and rescheduling of weekly STs This results in weekly STs demanding a higher degree of human intervention than STs with frequencies greater than 7 days which are scheduled automatically by PIMS Discussion The problem could have been avoided by application of Guideline 2 3 1 4 Functional Completeness of Software Requirements The guideline states in part All functions allocated to software from the system requirements document should be documented in the software requirements 64 0043 Date Uncertainty Date 5 3 2000 Source LER 362 2000 002 Domain Nuclear power Function Leakage rate determination Guidelines 2 5 3 3 Description The NRC resident inspector questioned the data used for calculating the Reactor Coolant System leakage for Unit 3 Southern California Edison SCE determined that the data were in fact incorrect The cause of the data error was a latent Y2K related problem in the way the computer
20. ckup computer also failed as a result of this error The primary and backup computers were restarted at about 10 32 A M and 10 36 A M respectively The cause of this event was an equipment failure During the reboot of the primary computer the network server function for the security computers did not start However the boot sequence continued until the main security program started on the primary computer Without the network server function the two computers could not completely communicate and consequently could not fully function The main security program was not capable of recognizing that the network server function had not started and tried to regain the primary role in the security monitoring system As a result a conflict arose and the backup program became unstable and failed to function Since the primary had no network server function it could not communicate properly leaving both primary and backup down Discussion The original cause of the failure was that initialization requirements did not cover start up from unusual conditions Guideline 2 3 2 3 causing a communication link to be dropped The problem was compounded by lack of robustness in that requirements for neither the primary nor the back up computer provided for verification of the presence of the communication link Guideline 2 5 2 3 32 0032 Thermal Power Calculation Date 1 14 98 Source LER 220 1998 003 Domain Nuclear power Function Reactor thermal powe
21. d form The requirements for the C873 data did not foresee that this would be the preferred means of establishing thermal power output and did not provide sufficient accuracy Guideline 2 2 1 53 0033 Disabled Function Date 10 28 99 Source LER 247 1999 019 Domain Nuclear power Function Position deviation alarm Guidelines 2 3 1 4 Description On October 28 1999 with the unit at 99 power during surveillance testing the alarm limits for the control rod position deviation rod vs bank alarm were discovered to be plus or minus 24 steps The design alarm limits are plus or minus 12 steps The rod position monitoring system had erroneously been allowed to be disabled due to lack of proper software configuration control of software upgrades related to the Y2K issue The contractor performing the upgrade had been allowed to disable functions that were thought to be obsolete and Con Edison assumed responsibility for determining disposition Due to an oversight that review of disabled programs was never completed As a result the unit was placed in operation with the RODLOW program disabled Discussion The overall software requirements apparently contained no provision to assure that all required functions were present Functional completeness of software requirements Guideline 2 3 1 4 54 0034 Snubber Inspection Scheduling Date 7 16 98 Source LER 270 1998 004 Domain Nuclear power Function Scheduling software Guidelines 2 6 3
22. des 514 E A A a RENE ERE 19 GOL Ele vator SOl wale tz vo oss Cal as e aa uds e Gola ao 20 0012 GPS Clock Problem 5x9 da eng A I KE ea d REA RR 21 0013 Electrostatic Discharge 25 er uA Pronin a 22 0014 TDWR Crash Failure AI A ONERE E E eds 23 0015 TDWR Communication Failure 0 2 0 eee no 24 0016 Weather Failure Due to Telco Circuits llle 25 0017 TDWR SW Failure 40 cias bade hh oa io de ORE ea ea iiin 26 0015 Weather Processor Crash esp ra a 27 0019 Indianapolis ARTCC Outage 0 0 II 28 0020 Boston ARTCC Outage isle Re ead RISE ER re eer RI ERR 29 0021 F 16 Weislitton Wheels in a SEE NER MES X UE ME dE ARM k 31 0022 Stores Management sd a ds eel e a de ta ub o 32 0023 747 400 Uncommanded Throttle Closure o oooooooocoonoronoomo 33 0024 A320 Article in Science amp Vie 4 jad od ds 33 Table of Contents 0023 74 T Problems cda is E AA tie d e oet e IUD titre CDU as 41 0026 Train Signal System Software 0 cece eee 43 0027 NASDAQ OUIABG ostias ty hee ENDE TR XN ERU x SNP XE SE 45 0028 Subway Doors izo rata o Rd CRG ORY LAG DER EA a da 47 0020 London Subway DOOIS ed ceo Ee t a e RET pieta 49 0030 747 Engine Shut Down Ps ous ADIDAS Re nbn x e RR OCA io no SIC eR 51 0031 Security Computer Failure oooo ooooooooooocor II 32 0032 Thermal Power Calculation ids vues vex e xr SR DEEST x UE Me RR SS 53 0053 Disabled Functions oss ad Sia eva ots eoe s etat aen aU eS do e tatu as 54
23. eed to review requirements for response to temporary conditions This cause of potential failures is classified as an example of cancellation of partially completed operations Guideline 2 5 3 3 The description indicates that scanning the platform for unsafe conditions is up to the individual operator Proper requirements would identify a response to such situations This cause of potential failures is classified as an example of response to events Guideline 2 9 2 50 0030 747 Engine Shut Down Date 10 3 90 Source Risks 10 10 Neumann 2001 Domain Aircraft Function Engine control Guidelines 2 5 2 3 Description BA 747 400 Engine Failure Martyn Thomas lt mct praxis co uk gt Wed 3 Oct 90 15 21 58 BST Flight International 3 9 October reports that a British Airways Boeing 747 400 s No 1 engine electronic controls failed on takeoff at London Heathrow causing the engine to shut down The crew two pilots there is no flight engineer reported the status message engine controls and asked their technical support staff by radio for advice They were told You ve obviously lost control of that engine It s a FADEC failure FADEC Full Authority Digital Engine Controller BA says that the problem was a spurious signal from the electronic thrust reverse resolver If so the early diagnosis of FADEC failure could be wrong There has been a number of instances of spurious signals causing 747 400 engines to throttle back or
24. eight The expanded sample is performed in the same bay as the discrepant basket and is considered to be representative of the ice baskets The 20 baskets however are selected by the lead test engineer as ICEPICK has no capability to perform the sample expansion of 20 additional ice baskets The selection by the lead engineer is based on accessibility thus not random selection The cause of this condition was determined to be work practices in that computer code programmers failed to adequately incorporate Technical Specification requirements in the software code used to identify for refilling those ice baskets with a weight significantly below the Technical Specification requirement The software used to support the Ice Condenser surveillance program will either be revised or replaced Discussion Surveillance procedure software is part of the offline monitoring functions Guideline 2 6 3 for these functions states in part Requirements should specify for each of the system surveillance and monitoring operations the actions to be taken for each anomaly detected by the system monitoring function A basket below T S average weight is an anomaly that is to be expected and failure to select the additional 20 baskets therefore is not in compliance with the guideline 59 60 0039 Monitor Accuracy Error Date 6 28 2000 Source LER 316 2000 007 Domain Nuclear power Function Rod deviation alarm Guidelines 2 2 1 1 Description With Coo
25. entary technical notices RCTs distributed to A320 crews already comprised eleven pages whereas the RCTs of other aircraft in the Air France fleet rarely went beyond three pages Contrary to the fears expressed many times in the course of these last years not only by certain pilots unions but also by the American certification authorities Federal Aviation Authority FAA the electrical flight controls and the electronic engine control system which constitute the two great technological innovations of the A320 would never be the direct cause of any significant incident notably in stormy conditions During test just as in service the A320 was struck by lightning several times without the least influence on the flight controls The majority of the teething troubles and design faults of the A320 therefore concern more classical systems The report of the technical sub director of Air France is once again definitive Pressurization management of cabin communications CIDS pneumatic generation auxiliary power units APU have been for a long time an unacceptable reliability Everything is still not under control to this day NDLR 11th July 1989 Report already cited page 17 39 Industrial secret It could therefore be thought that the certificator has turned his attention above all to the innovative elements flight controls FADEC etc of the A320 However this explanation although not completely without foundation doe
26. es the aircraft was whitewashed as far as public opinion was concerned before the slightest preliminary accident report was published 35 Although what have come to be called the Chirac flight and the Habsheim affair are the two facts most known to the public the first year of operation of the A320 has been marked by numerous incidents which have directly called into question certain systems on the airplane Often badly received by the first crews qualified on this aircraft and sometimes vigorously denied by the technical directors of the launching companies these incidents lead one to ask if the manufacturers and the certification authorities have not proceeded a little too quickly For example there have been twelve times more incidents than were foreseen In his statement on the first year of operation of the A320 in the Air France fleet a statement addressed to the general department of civil aviation Direction Generale de I Aviation Civile DGAC on the 11th July 1989 the technical sub director of operations management of the national company remarks that the first exercise has been marked by a greatly increased number of technical incidents altogether page 12 Whereas the target set was one incident per thousand hours of flight the year 1988 ended with an incident rate of twelve per thousand hours of flight For comparison this rate was 5 1000 at the time of the first year of operation of the Airbus A300 The
27. et officials Wednesday s halt was caused by a software problem in its Small Order Executive System and its quote update system by Carlsbad Calif based SelectNet NASDAQ officials said they noticed the problem at 3 40 p m EST and suspended trading at 3 49 p m EST Technicians had restored the system incrementally by 4 p m EST We shut down on our own so that folks were not trading on stale quotes said NASDAQ spokesman Andy MacMillan It was a unique combination of circumstances that caused the problem but the problem was fixed by after hours trading Until the problem was fixed NASDAQ traders were unable to update and view new quotes The exchange also handled a higher than usual trade volume of approximately 2 billion trades NASDAQ s average share volume is 1 65 billion trades per day Problems with the order routing system have caused delays on two other occasions this year The SelectNet system experienced 75 minutes of update delays on April 4 That day investors traded 2 9 billion shares on the exchange and requested 6 5 million quote updates On Feb 18 a communication line malfunction disrupted the dissemination of last sale price data on NASDAQ for two hours 45 Technology is brittle said Jaime Punishill an analyst at Forrester Research in Cambridge Mass Considering it was down for less than 20 minutes and it has only happened twice this year I say the NASDAQ has done a pretty good job of keeping its technology u
28. evel Since pressure diminishes with altitude the value of QFE is generally less than 1 013 hPa The sudden alteration of the altimeter setting by the flight programming computer Flight Control Unit FCU sometimes occurs in uncomfortable conditions So in July 1988 during an approach to Roissy the untimely alteration of the altimetric setting which conveyed itself as a reversal of the altimeter reading provoked an automatic delivery of fuel in order to compensate for the false deviation in altitude generated by the defaulting computer and detected automatically by the safety systems of the aircraft This delivery of fuel occurred while the aircraft was being flown manually on its descent The rapid intervention of the pilot could not avoid the aircraft going into overdrive for several seconds Untimely alterations of altimetric settings showed up on at least the first three planes delivered to Air France among them the aircraft that crashed at Habsheim The commission of inquiry has revealed in its final report that such an incident had taken place on the plane several hours before its crash concluding immediately that this anomaly due to a design error had played no part at all in the accident Moreover the flight report CRM compte rendu materiel of a crew concerning a third aircraft of Air France made mention of vagaries of the altimeter It is therefore surprising that the report of the technical sub director of Air France limits this type
29. failure is classified as an example of lack of requirements for checking for completeness of interface Guideline 2 6 6 20 0012 GPS Clock Problem Date 10 23 98 Source Risks 20 07 Neumann 2001 Domain Aircraft Function Time sync Guidelines 2 2 1 2 Description GPS internal clock problem Bob Nicholson lt lattice popmail dircon co uk gt Wed 11 Nov 1998 08 20 39 0000 This has been reported earlier beginning in RISKS 18 24 but is still a problem PGN As a licensed aircraft engineer I regularly receive AIRWORTHINESS NOTICES from the British CAA Here is one verbatim that may be of interest CIVIL AVIATION AUTHORITY AIRWORTHINESS NOTICE No 7 Issue 1 23 October 1998 The Potential Resetting Of Global Positioning System GPS Receiver Internal Clocks 11 The timing mechanism within GPS satellites may cause some GPS equipment to cease to function after 22 August 1999 due to a coding problem The GPS measures time in weekly blocks of seconds starting from 6 January 1980 For example at midday on Tuesday 17 September 1996 the system indicates week 868 and 302 400 seconds However the software in the satellites clocks has been configured to deal with 1024 weeks Consequently on 22 August 1999 which is week 1025 some GPS receivers may revert to week 1 1 e 6 January 1980 12 Most airborne GPS equipment manufacturers are aware of the potential problem and either have addressed the problem prev
30. failure probability The cause of this communication failure is classified as an example of lack of independence and redundancy requirements at both the system and software levels Guideline 2 5 1 2 24 0016 Weather Failure Due to Telco Circuits Date 11 19 00 Source AMBRIEFS FAA 2000 Domain Air traffic control Function Weather radar Guidelines 2 5 1 2 2 6 1 Description DETAILS At 7 30 AM EST the Terminal Doppler Weather Radar Service TDWRS failed due to a Telco circuit interruption The weather was clear and the Wind Measuring Equipment WME was available Note Telco circuits are required to be redundant The failure indicates that redundant circuits shared a common element RESOLUTION Specialists notified MCI Worldcom who investigated under ticket 1 1 19 0562 Verizon dispatched a technician to the site who replaced a faulty card in a T 1 circuit but the problem persisted Troubleshooting continues Discussion Redundant communication channels shared a single weak link The requirements should have called for identification and avoidance of correlated failure probability The cause of this communication failure is classified as an example of lack of independence and redundancy requirements at both the system and software levels Guideline 2 5 1 2 Inability to identify the cause of the failure indicates lack of diagnostic requirements This cause for extending the time for restoration of service is classified as a
31. five minutes for the next rush hour train or ten or twenty minutes off peak blocking the doors open in the vain hope the conductor will re open and let them in As a previous RISK poster noted this all depends on the conductor s mood and if s he is in a hurry or not It also depends on their line supervisors some managers emphasize speed others passenger safety A few years ago the Transit Authority had a problem with doors opening enroute on the older pre 1976 or so cars an individual door would open while the train was in motion once on a speeding express train thankfully no one was hurt The TA rewired all their newer trains with an interlock so that the emergency brake would activate if the doors opened while the train was in motion You can experiment with this safety interlock by attempting to force one of the doors open while the train is moving One day I observed two teenagers on the way to Brooklyn doing exactly that thrilling over pushing open a door two inches as the train sped through the tunnel When I warned them that they would kick in the emergency brake if they went too far they had a spell of enlightened self interest it can take ten or fifteen minutes for the crew to reset the emergency brake and left the poor door alone 47 Ed Ravin Prodigy Services Company White Plains NY 10601 elr trintex UUCP Discussion That opening of a door would not bring a moving train to an immediate stop indicates lack of
32. frequency of these incidents that have marked the A320 going into service within Air France Air Inter and British Airways has forced the manufacturer to publish no fewer than 52 provisional flight notices Operations Engineering Bulletins or OEBs between April 1988 and April 1989 The launch of a new aircraft requires on average four times fewer notices OEBs are temporary notices sent out by the manufacturer to the users They form a list of anomalies or simply functional features of the aircraft that do not appear in the user s manual for the equipment FCOM Flight Crew Operation Manual they are only revealed in the course of operation In the case of Air France these provisional records are provided to the crews in the form of a volume of supplementary technical information notices Renseignements Complementaires Techniques RCT Ss For the A320 the number of OEBs alone gives an account of the problems of putting the aircraft into service At the technical level around twenty of the fifty main computers of the first A320s coming off the production lines in Toulouse have had to undergo modifications for the A320 is the first aircraft in the world to be completely computerized Computers control the function of all the systems of the airplane motors ailerons but also the cabin lighting etc it sic processes raw data converts them and transmits them to the pilot Now the application of numerous modifications defined by the manufacturer
33. h keeps track of equipment malfunctions in 75 separate systems when the plane is on the ground was not fully debugged when Boeing began delivering its first 400s last year Davis said The 400 s performance record lagged so badly behind previous jetliner models that the company formed a special task force last month to whip the plane into shape Davis who heads the task force said the unit has started improving the 400 s dispatch reliability rate the measure of how frequently the planes are delayed more than 15 minutes at the boarding gate because of mechanical malfunctions Davis said none of the problems encountered in the 400 could cause the plane to be unsafe to operate But Boeing has received complaints across the board from airlines that own the jetliner Davis said 41 Boeing said it expects to cure the glitches in the 400 by making changes on its production line next month So far about 20 of the 57 400s already in operation have been retrofitted since October Discussion The problems in the power control computer and in the maintenance computer may need separate corrective measures but they share a common root cause in that requirements for sensor data processing were incorrectly stated and not verified The common aspect of these failures is classified as an example of incorrect sensor data processing Guideline 2 5 2 1 42 0026 Train Signal System Software Date 7 23 90 Source Risks 10 15 Neumann 2001
34. h one F 16 Discussion Requirements should have prevented raising the landing gear while the aircraft was on the ground The aircraft being on the ground is normally sensed by the weight on wheels switch This very easily incorporated signal would have prevented the failure This cause of failure is classified as an example of lack of requirements for conditions under which mode changes are permitted Guideline 2 3 1 6 3l 0022 Stores Management Date 10 1 86 Source Neumann 1986 Domain Flight control Function Stores management Guidelines 2 3 1 1 Description In the F16 the onboard computer system has a weapons management system that will attempt to keep the plane flying level by dispensing weapons and empty fuel tanks in a balanced fashion So if you ask to drop a bomb the computer will figure out whether to drop a port or starboard bomb in order to keep the load even One of the early problems with that was the fact that you could flip the plane over and the computer would gladly let you drop a bomb or fuel tank Discussion This potential failure mechanism could be avoided by complete specification of the conditions for releasing stores This cause of failure is classified as an example of lack of complete definition of the hardware and software runtime environment Guideline 2 3 1 1 32 0023 747 400 Uncommanded Throttle Closure Date 4 11 90 Source Risks 10 04 Neumann 2001 Domain Flight control Function Autoth
35. he default action works great when the clutch is engaged In my case I ended up with a car that suddenly became very hard to control when I was already doing something unsafe Discussion The unsafe condition was due to a faulty assumption in the requirements that high speed was due to use of the engine The cause of the failure can be classified as examples of a Forbidden transition engine running to engine off while automobile at speed Guideline 2 3 1 6 b Improper specification of interlocks Guideline 2 3 4 2 c Improper operator interface Guideline 2 9 8 14 0007 A Subtle Fencepost Error Date 11 19 00 Source Risks 21 05 Neumann 2001 Domain e Commerce Function Order entry Guidelines 2 3 4 1 Description I recently got email from amazon com offering me a 50 discount on any order of 100 or more from ashford com As it happens my wife s wristwatch needed repair and I decided that for 50 I wouldn t mind buying her another watch if I could find one I thought she would like I found such a watch for exactly 100 When I tried to order it the ashford com website wouldn t accept my promotional offer code More precisely it accepted it but didn t indicate any discount So I called them on the phone The very pleasant sales rep said that he could place the order for me When he tried though he also found that their system wouldn t accept the promotional code He then told me that he would go ahead and place the o
36. he immediate vicinity of the airport primarily for take off and landing ICSS The means by which flight data messages are sent to and from the approach control facility Discussion The requirement died not consider the effects of electrostatic discharge This cause of failure is classified as an example of avoiding harm to operator at the human computer interface Guideline 2 9 10 22 0014 TDWR Crash Failure Date 11 19 00 Source AMBRIEFS FAA 2000 Domain Air traffic control Function Weather radar Guidelines 2 6 3 2 4 6 Description At 11 10 PM CST the Terminal Doppler Weather Radar TDWR failed during clear weather The Low Level Windshear Alert System LLWAS was available A specialist was called out and performed a remote system reset and software reload via the Maintenance Data Terminal MDT at the tower The system was returned to service at 12 55 AM Discussion There had been repeated failures of this type e g See Failure Description Nos 3 15 and 3 16 The requirements did not mandate that conditions surrounding a system crash be completely described and recorded to support attacking the root causes In the absence of such requirements the technician concentrated on restoring operation as fast as possible This cause of failure is classified as an example of lack of offline diagnostic requirements Guideline 2 6 3 When recurring problems are encountered a failure rate should be determined to support man
37. hours was not met and this constituted a condition prohibited by the plant s Technical Specification The core monitoring program runs in two modes full and mini The latter executes only INPAX while the full mode includes other functions as well The mini mode executes automatically every 8 hours The full mode which has priority over the mini mode executes when there is a power change of more than 2 596 During a down power test the full mode was invoked but did not run to completion due to a software error introduced by a recent change This blocked execution of the mini mode Discussion A program that executed only partially due to a software error see below was allowed to block the execution of a required program and there were no alarms to announce this condition Guideline 2 5 3 3 states in part Requirements should specify which functions can be cancelled prior to completion and how the operator will be notified The initiating condition was improper execution of a software change and lack of a complete test This could have been avoided by adherence to Guideline 2 6 4 Requirements to Allow Technician Maintenance 63 0042 Missed Surveillance Test Date 6 29 98 Source LER 353 1998 005 Domain Nuclear power Function Scheduling software Guidelines 2 3 1 4 Description On 06 29 98 the Surveillance Test ST coordinator discovered that procedure ST 6 107 887 2 which has a weekly frequency had exceeded its Technic
38. ight management Maintenance Guidelines 2 5 2 1 Description 747 400 computer problems cause excess departure delays Jon Jacky University of Washington lt JON 9 GAFFER RAD WASHINGTON EDU gt Mon 25 Jun 1990 17 33 41 PDT Here are excerpts from the Seattle Post Intelligencer March 22 1990 p B7 BOEING TASK FORCE TACKLES PROBLEMS WITH THE 747 400 by Bill Richards After a year on the job Boeing s newest jumbo jet the 747 400 has piled up more mechanical delays at the departure gate than any of the company s jetliners since the first 747 went into service 20 years ago Boeing officials said yesterday they knew about problems with two especially troublesome pieces of equipment a computerized power unit used to start the planes engines and a computer that spots maintenance problems but decided to sell the jumbos anyway Boeing official Robert A Davis said the problem with the 400 s engine power unit was caused by unusual sensitivity in the unit s digital monitoring system If the plane switches from ground power to auxiliary power to engine power in the wrong sequence the engines shut down and must be restarted which results in a delay at the gate he said Boeing engineers were aware of the problem during the plane s flight tests said Davis but decided to maintain the plane s sales schedule and troubleshoot later Boeing also discovered a problem with the plane s central maintenance computer during flight tests The computer whic
39. ime control Function Barricade access Guidelines 23 31 2 5 2 1 Description In RISKS 19 97 we reported on a Pentagon security system that injured the visiting Japanese defense minister and five others when a barricade was raised at the wrong time in September 1998 That accident was attributed to a faulty sensor and resulted in the installation of a new barricade control system On 5 Aug 2000 the same barricade sprang up under the German defense minister who arriving for a Pentagon honors ceremony was injured and briefly hospitalized along with the German defense attach and an American security aide Source Reuters item cited in the New York Times 6 Sep 2000 Discussion The barricade control system needed to be reviewed not only from perspective of security but also for safety since it was capable of causing injury Sensor failures are common occurrences and provision for the system to remain in a safe state after a sensor failure should have been incorporated at the outset This cause of the failure is classified as an example of inadequate requirements for handling of sensor data Guidelines 2 5 2 1 The requirements should have been reviewed particularly after the first failure to provide for safe operation under off nominal conditions This cause of the failure is classified as an example of incomplete specification of I O parameters including operation under off normal conditions Guidelines 2 3 3 1 10 0004 Single P
40. ion Disabling the alarm below 15 RTP without putting alternative surveillance methods into effects violated the Technical Specification This condition would have been avoided by conforming to Guideline 2 1 1 Software requirements should address all system functions allocated to the software necessary to fulfill the system s safety intent 58 0038 Incomplete Surveillance Software Date 3 12 98 Source LER 315 1998 015 Domain Nuclear power Function Ice bucket surveillance Guidelines 2 6 3 Description On March 12 1998 with Unit 1 and Unit 2 in Mode 5 plant personnel identified that the Ice Condenser Technical Specification required ice basket weights were not being adequately maintained The Ice Condenser absorbs thermal energy released during a coolant leak inside Containment to limit the peak pressure and consists of 1944 ice baskets each filled with a required minimum of 1333 pounds of borated ice The inability to maintain the required amount of ice in each ice basket if it had been found during operation may have resulted in the plant being in an unanalyzed condition and in accordance with 10CFR50 72 a 2 1 an ENS notification was made at 1930 hours EST that day ICEPICK a computer software random number generator is utilized to pick the initial 144 ice basket sample The minimum 144 ice basket sample is required to be expanded for 20 additional ice baskets for each ice basket determined to be below the T S average w
41. ion of IEEE 279 calling for manual initiation of all plant protective functions would have been applicable If this installation had been subject to these provisions the failure would also have been classified as an example of lack of manual initiation Guideline 2 3 4 9 13 0006 Saturn Limit Logic 11 07 00 Date Source Risks 21 09 Neumann 2001 Domain Automotive control Function Safety interlock Guidelines 2 3 4 2 2 9 8 2 3 1 6 Description As a safety feature my Saturn will prevent me from going faster than is safe with my suspension or tires When I first got the car I had to try this feature out so I found a long straight road and floored it When I got to 105 mph the engine lost power and I slowed down Experimentation revealed that I couldn t regain power until I dropped below 100 then I could accelerate again A couple of days ago I drove through a fairly steep chasm with a road straight down one side and up the other I figured I needed as much momentum as possible so I pushed the clutch in and coasted down Somewhere along the way I hit 105 mph Just as I was starting up the opposite side I noticed that virtually all of my warning lights were on and the engine was at 0 RPM A still engine means no power steering and no power brakes I m quite glad there weren t any turns or traffic that might have forced me to turn or brake The problem was the assumption that I got to an excessive speed by using the engine to accelerate T
42. ionic terms or who knows the correct English avionic terms is welcome to correct me It is advisable to add to these outcomes the grounding of aircraft due to suspect behavior and 74 cancellations of flight before even starting up the engines Reliability in question For the aviation companies the most serious problem would seem to have been that of the reliability of the information given to the crew by the various systems of the A320 The operating assessment by the technical sub director of Air France is edifying on this subject One discovers there for example that certain inconsistencies of piloting information have led to certain confused and very distracting situations where the information presented to the pilots on the control screens during flight was in contradiction to the physical reality of the equipment not always verifiable in flight report already cited page 18 Presumably this means The instruments were lying but the pilots couldn t get out and walk around to check this at 30 000 feet Nice to know that French technical officialese is as obscure as British or American Without a doubt Captain Claude Dalloz and First Officer Patrick Vacquand share the views of the technical sub director of Air France On the 25th August 1988 while taking off from Roissy on a flight to Amsterdam flight AF 914 they had the disagreeable surprise of seeing the message Man pitch trim only appear in red on their control screens
43. iously or are working to resolve it However there may be some GPS equipment including portable and hand held types currently used in aviation that will be affected by this potential problem 2 0 Action to be taken by aircraft operators who use GPS equipment including portable and hand held types as additional radio equipment to the approved means of navigation should inquire from the GPS Discussion The software requirements did not consider the range ofthe data to be processed This cause of failure is classified as an example of error in data size and precision requirements Guideline 2 2 1 2 21 0013 Electrostatic Discharge Date 11 19 00 Source AMBRIEFS FAA 2000 Domain Air traffic control Function Communications Guidelines 2 9 10 Description At 9 53 AM EST an electrostatic discharge ESD occurred causing the V 3 East Arrival Integrated Communications Switching System ICSS position to fail The controller felt the ESD through her headset She filed a CA 1 form but elected not to have a medical exam The specialist replaced several components and remapped the position to restore the V 3 position at 1 54 PM The ESD was attributed to low humidity in the Terminal Radar Approach Control TRACON The carpet will be sprayed with anti static material after the TRACON closes on 11 19 The headset was removed from service by Air Traffic for further inspection TRACON The facility at which controllers direct aircraft in t
44. k Unit 2 at 79 6 percent rated thermal power RTP a shutdown was initiated due to failure to meet Limiting Conditions of Operation LCO Two Individual Rod Position Indicators IRPIs deviated from the group step counter by more than the 18 step allowed deviation During the event the Rod Position Deviation Monitor RPDM failed to annunciate when the 18 step limit had been reached The cause for this was that the plant computer software installed in the early 1990s contained an error such that the alarm was generated from a greater than condition rather than greater than or equal Discussion The failure of the RPDM to annunciate is due to a frequently encountered problem in distinguishing between greater than and greater than or equal The corresponding requirement is addressed in Guideline 2 2 1 1 Accuracy requirements should be stated explicitly 61 0040 Deficient Surveillance Test Procedure Date 9 9 1999 Source LER 334 1999 011 Domain Nuclear power Function Axial flux difference alarm Guidelines 2 3 1 4 Description On September 9 1999 it was identified that the Operations Surveillance Test IOST 5A 1 Delta Flux Alarm Program Operability Check was inadequate to support the Beaver Valley Power Station BVPS Unit 1 Technical Specification TS 3 4 2 1 The Axial Flux Difference AFD monitor alarm has not previously been sufficiently proven to be operable by a suitable periodic surveillance test and th
45. ls existed for the review of the software revision This allowed the software change to be implemented without review of potential impact on plant systems In addition the program design description was insufficiently detailed Discussion The licensee s description puts major emphasis on change control and that aspect is covered by Guideline 2 6 4 Requirements to Allow Technician Maintenance In addition the functionality aspects of the requirements appear to have been deficient with respect to Guideline 2 3 3 2 which states in part In the course of reviewing software requirements it should be demonstrated that data from all sensors needed for monitoring and control of safety functions are identified and the number and location of sensed parameters is adequate 67 4 References Copeland L Software glitch forces 11 minute shutdown of NASDAQ Computerworld http www infoworld com articles hn xml 00 12 01 001201hnnasdaq xml p br8s 7 1207thpm FAA Federal Aviation Traffic Management Center Daily Morning Briefing Summaries Database 2000 Neumann Peter Risks to the Public ACM Software Engineering Notes Vol 11 No 5 P 6 October 1986 Neumann Peter Risks to the Public Electronic newsletter available at http www csl sri com risko risks txt and http catless ncl ac uk Risks 2001 68
46. n example of inadequate requirements for diagnostics Guideline 2 6 1 25 0017 TDWR SW Failure Date 11 14 00 Source AMBRIEFS FAA 2000 Domain Air traffic control Function Weather radar Guidelines 2 6 1 2 5 2 1 2 4 5 Description DETAILS At 9 36 AM EST the Terminal Doppler Weather Radar TDWR failed in clear weather due to a Radar Products Generator RPG fault The Low Level Windshear Alert System LLWAS was available RESOLUTION The specialist reloaded the software and reset the TDWR Diagnostics were then performed and the system was monitored before being returned to service to assure system reliability The TDWR was returned to service at 11 00 P M Discussion Diagnostics in this case supported testing monitoring prior to placement of unit back into service Although not a cause of failure the event emphasizes the need for offline diagnostics Guideline 2 6 1 The RPG fault was a foreseeable event and requirements for exception handling might have prevented it from causing failure of the service This cause of failure is classified as an example of incomplete requirements for exception handling leading to software failure Guideline 2 5 2 1 When recurring problems are encountered See Failure Description Nos 14 and 16 a failure rate should be determined to support management decision making and to help in the evaluation of fixes e g Did a corrective measure reduce the failure rate This contribution to the
47. n two channels affecting over power delta temperature and over temperature delta temperature were placed in bypass on three occasions instead of keeping one channel in the tripped condition The condition lasted less than one hour therefore Technical Specification 3 0 3 was met On March 21 1999 at 0136 PST Channel 1 was being tested in the tripped condition When the testing software detected an electronic communication error the test automatically aborted The aborting process changed the condition of the channel from tripped to normal Technicians returned the channel to tripped within 2 minutes and operators requested the event be evaluated for reportability as a TS violation Discussion The abort process should have restored the channel status to its previous tripped condition rather than to normal Guideline 2 5 1 1 states Requirements should identify all foreseeable exceptions and system errors and specify how they are to be handled 56 0036 Inspection Procedures Date 1 8 99 Source LER 282 1999 002 Domain Nuclear power Function Circuit breaker inspection Guidelines 2 3 1 4 2 6 3 Description On January 8 1999 while Prairie Island Nuclear Generating Plant PINGP Unit 1 was at hot shutdown due to the 1M transformer fault surveillance procedure SP 1016 RCP Breakers Test was being performed Per the SP the 11 Reactor Coolant Pump RCP was stopped and Bus 11 was de energized At 0852 during the execution
48. naccuracies but more frequently it is only through failures in actual operation that these defects are made manifest This is the second of two volumes prepared under Contract RES 00 037 and contains a set of 45 failures that illustrate the need for and the importance of specific requirements review guidelines Cross reference tables link the requirements review guidelines to the failure descriptions and the failure descriptions to the guidelines A D APU ARTCC CFR CCCH CCU CPU D A DHCP EPRI ESFAS FADEC FDIO FMEA FMECA HVAC I amp C IEEE LSB NRC P amp ID PLC RTS PDS PID UPM SAR TRACON TTL V amp V List of Acronyms Analog to Digital Auxiliary Power Unit Air Route Traffic Control Center Code of Federal Regulations Central Computing Complex Host Central Control Unit Central Processing Unit Digital to Analog Dynamic Host Configuration Protocol Electric Power Research Institute Engineered Safety Function Actuation System Full Authority Digital Engine Controller Flight Data Input Output Failure Modes and Effects Analysis Failure Modes and Effects and Criticality Analysis Heating Ventilation and Air Conditioning System Instrumentation and Control Institute of Electrical and Electronics Engineers Least Significant Bit Nuclear Regulatory Commission Process and Instrumentation Diagram Programmable Logic Controller Reactor Trip Systems Previously Developed Software Proportional Integral Derivative C
49. ne diagnostics Guideline 2 6 1 Buffer overflow during attempt to transmit caused by full queue indicates lack of requirements for accurate estimation of maximum queue size This cause of failure is classified as an example of insufficient requirements for estimating the maximum queue size Guideline 2 5 2 7 27 0019 Indianapolis ARTCC Outage Date 11 13 00 Source AMBRIEFS FAA 2000 Domain Air Traffic Control Function En route systems Guidelines 2 5 1 1 2 4 2 Description DETAIES At 4 05 PM EST the Indianapolis IN ZID Air Route Traffic Control Center ARTCC experienced a loss of critical power that interrupted all air ground communications radar displays and automation systems Operations declared ATC Zero and activated the ATC contingency plan The Air Traffic Control System Command Center ATCSCC coordinated a national ground stop for traffic to and through ZID airspace RESOLUTION The CMOS chips in each of the circuit cards were weakened or faulty due to exposure to electrostatic discharge ESD This damage was confirmed through comparison probing of the circuitry before and after the cards that contain the CMOS chips were replaced All the UPMs uninterruptible power modules have been tested They will now have the defective cards replaced and be retested and aligned individually and as a combined system All 51 cards are bad 45 in the UPMs and 6 in the Bypass Transfer Control System were verified as bad thro
50. neral digital controls field and 15 from nuclear power plants were included Table 2 1 provides a list of the failure descriptions and cross references the descriptions to the guidelines in Volume 1 Table 3 2 provides the reverse mapping 1 e guidelines to failure descriptions The failure descriptions from the general digital controls field are anecdotal They are not formal failure reports and are intended for the purposes of illustration only Failure descriptions from the nuclear field were excerpted from licensee event reports LERs and tend to be more complete None of the failure descriptions have been independently verified Table 2 1 Failure Reports to Guidelines Vol 1 Cross Reference UPS Backup Failure 2 1 3 2 9 4 2 3 4 9 Disabled Function 0044 Rod Position Calculation 2 3 1 4 0045 Reactor Power Calculation 2 3 3 2 2 6 4 Table 2 2 Guidelines Vol 1 to Failure Reports Cross Reference Guidelines N na 1 Ra Train Signal System Software Thermal Power Calculation Monitor Accuracy Error 0012 GPS Clock Problem 0002 Decimalization and Ford Stock Splits 0001 Configuration Management on User 0022 Bombing While Flying Upside Down 0033 Disabled Function 0036 Inspection Procedures 0040 Deficient surveillance Test Procedure 0042 Missed Surveillance Test 0044 Rod Position Calculation Saturn Limit Logic 0021 F 16 Weight on Wheels Security Computer Failure 0017 TDWR SW Failure Guidelines Failu
51. of incident to a single A320 of his fleet the aircraft registered F GFKB when it has also occurred on at least two other planes registered F GFKA and F GFKC But the most amazing thing remains that this functional anomaly should cease without anyone being able to identify its origin Recording of parameters In an indirect manner these two types of incidents have revealed another potential source of problems in the level of the recording of parameters by the black box recorder DFDR Digital Flight Data Recorder In effect each piece of information given to the pilot is handled by a cascade of computers Now this black box records the majority of its information on the intermediate computers and not at the start or end of the processing chain When examining this data 38 therefore there is nothing that allows one to know precisely what the pilots had for information since there is no recording at the output of the symbol generator DMC for their screens The problems posed by the flight data recording system can be illustrated by referring to the two incidents mentioned If the Paris Amsterdam flight recalled above had ended in a crash the black box recorder which captures a large part of its information from the flight warning computer FWC would have revealed that the crew no longer had pitch control available In fact all the flight controls were functioning but the flight warning computer which is one of the princi
52. oints of Failure and Inadequate Backup Plans Date 09 25 00 Source Risks 21 05 Neumann 2001 Domain Internet Function DHCP Guidelines 2 8 4 2 5 2 1 Description Monday 25 September 2000 17 00 37 0400 Last night our cable modem currently AT amp T Roadrunner name subject to change daily stopped working and the constant busy signals from their tech support line led me to believe it wasn t merely Yet Another Outage TM Strangely my cable modem lights were all doing the right thing and when I checked with my neighbors their cable modems were working fine After a couple of hours of redialing I finally got a message saying that there were unspecified problems that they were working on strange usually they list the affected towns and after some time on hold I finally talked to a tech support rep who offered to help if I can Tums out the DHCP server for the entire northeast went down and as people s leases on their IP addresses expired they were dropped off the network I asked about the secondary or backup DHCP servers but apparently there was so much demand due to expired leases that the backup server couldn t respond quickly enough and was getting overloaded with requests Discussion The network requirements did not provide adequate capacity of the backup DHCP to permit handling of demands that would arise from a foreseeable recovery condition This cause of the failure is classified as an example of inadequate capaci
53. ontrol Uninterruptible Power Module Safety Analysis Report Terminal Radar Approach Control Center Transistor Transistor Logic Verification and Validation 1 Introduction This document is the second volume of the Digital Systems Software Requirements Guidelines Together with Volume 1 it provides guidance to the NRC for reviewing high integrity software requirements documents in nuclear power plants This volume contains requirements related failures that substantiate and illustrate the requirements guidelines of Volume 1 Chapter 2 of this volume provides an overview of the failure reports and Chapter 3 presents the failure description sheets The following appendices of Volume 1 will also be found helpful to the reader of this document Appendix A Glossary of Technical Terms Appendix B Reviewers 2 Overview of Failure Descriptions The failure descriptions contained in this section were selected from sources in the general digital controls field and in digital controls applied to nuclear power plants The following list summarizes the criteria used to select relevant failure examples e The failure resulted from multiple causes e The proper definition and implementation of a software requirement would have mitigated or prevented the failure e The failure did or could have had safety significance e The failure was adequately documented Although many hundreds of source failure descriptions were examined only 30 from the ge
54. orches over the patient s abdomen in shifts to prevent their arms becoming stiff According to the Guardian the operation succeeded because the patient required only a local anaesthetic and because the obstetrician had worked for ten years in Africa He was used to operating not just under torchlight but under candlelight According to the Telegraph there was also a heart patient who died in an ambulance outside where paramedics were trying to revive him The hospital denied that the power cut was a contributory factor in his death RISKS readers will recognize a number of too common failings such as the lack of easily usable manual overrides and a failure to test fallback modes of operation properly Above all there seems to have been a violation of the KISS principle As Christopher Strachey said It s impossible to foresee the consequences of being clever Clever failsafe mechanisms should be avoided By Ross Anderson Discussion The requirements for monitoring the line voltage and starting the generators were incorrect and had not been verified This cause of failure is classified as an example of incorrect and unverified logic Guideline 2 1 3 12 When power was restored it should have been possible to override the automatic control system and return to normal power This cause of the failure is classified as an example of inadequate requirements for manual overrides Guideline 2 9 4 In a nuclear power environment the provis
55. p to snuff Discussion The description does not provide sufficient information to assign a specific cause in the program though there are indications that failures are volume related meaning insufficient capacity planning However when repeated failures are encountered it should be possible to state whether quantitative reliability or availability requirements were defined and whether they were being met This aspect of the failures is classified as an example of importance of quantitative reliability and availability requirements Guideline 2 4 6 46 0028 Subway Doors Date 1 10 91 Source Risks 10 77 Neumann 2001 Domain Ground transportation Function Automatic doors Guidelines 2 5 2 1 2 5 3 3 2 9 2 Description SMH Home Text only index From Risks 10 77 Vicious Subway Cars was Vicious Elevators Unix Guru in Training lt elr trintex uunet UU NET gt Thu 10 Jan 91 12 42 54 EST Here s a quick rundown on RISKS of stepping through the doors on a New York City subway car each of the twin doors can be as much as 3 inches open when the train starts moving giving you a maximum gap of 6 inches Although an interlock prevents the train from starting while the doors are open called the indication by the train crew the sensors aren t too precise People can and do get dragged by moving cars when they re stuck in the doors Usually it s their own fault hyped up New Yorkers who won t wait the next three or
56. pal sources of information of the black box recorder had failed diagram p 98 Equally if the untimely alterations of the altimeter readings had ended in a crash the black box recorder would have revealed no malfunction of the altimeter assembly since the recording of pressure altitudes ONE which was correct is affected by equipment located upstream of the failing computer This computer FCU incorrectly processed the information that had been sent to it and an erroneous indication of altitude was sent to the control screens diagram above p 99 Modification Campaigns Before the A320s went into service the launch companies instructors who cannot be accused of bias since they were all volunteers complained of having had no contact with the test pilots of Airbus Industries The report of the technical sub director of Air France for its part confirms this worry by revealing that it had at last been possible to establish a frank relationship page 17 after six months The adaptation of failing systems has been progressively integrated in the course of several modification campaigns begun at the start and middle of 1989 as problems were found and listed It was necessary to wait until the end of last year to obtain the definitive version of certain pieces of equipment that is to say eighteen months after the certification and entry into commercial service of the A320 At the end of last year the dossier of supplem
57. people on the platform made him stop Network Southeast An elderly woman boards the train Underground Piccadilly Line and the driver closes the doors and moves off before her equally elderly husband can get on I leaped onto a crowded tube train Underground Metropolitan Line carrying a shoulder bag just as the doors were closing I got on but my bag didn t The doors closed around the strap and the train 49 moved away with the bag hanging outside the carriage and me pinned to the door by the strap around my shoulder just waiting for the first obstruction to snag the bag Fortunately someone pulled the emergency handle and the train stopped before it entered the tunnel What has this got to do with computers Not a lot All these incidents occurred with a human in the loop just one human and obviously not very firmly in the loop I think that less not more automation is the answer to safety here Bring back the guard I went through King s Cross on the Circle Line while the fire was raging a few years ago They re gonna get me one day Discussion Safety considerations for public transport should preclude trains from moving when articles of attire are protruding on the outside In terms of nuclear reactor safety this is a design basis event This aspect of the failure is classified as being incomplete with regard to design basis Guideline 2 1 1 Separation of mother from children or other dependents indicates a n
58. plans and General Information GIs RESOLUTION Initially the issue appeared to be a modem problem After further investigation by the host specialist it was determined CCU 3 would not switch and the secondary CCU seemed to be inoperative the EEM installation was causing the problem The specialists coordinated a host shutdown from 2 45 to 3 30 PM removed CCU 3 and reverted to the previous version of software Operations continued using Direct Access Radar Channel DARC only A ground stop and Mile In Trail MIT restrictions were implemented Air Traffic completed the transition back to normal operations at 4 00 PM AOS personnel arrived onsite to assist in the investigation during the 11 04 midshift The preliminary assessment indicated a combination of factors were responsible for the host error messages slowdown and abort One of the sites interfacing the CCU Falmouth has been a source of intermittent interruptions for several months This alone has not caused a host operational problem However a LAN hardware problem in CCU 3 combined with the Falmouth circuit problem caused a host queue buildup and this buildup is suspected to have caused the saturation warnings leading to the host abort The core dump from the abort will be analyzed by AOS on 11 04 to determine whether the abort was caused by the queue buildup Also preliminary analysis indicates a specialist was attempting to manually switch control units to work around the error mes
59. program handled year 2000 dates If the data collection date and the calculation date are the same the program considers the dates consistent and performs the leakage rate calculation If the collection date and the calculation date are different as was the case here the program replaces the input data with data taken at the time of the calculation As a result all volume differences were incorrectly stated as zero Discussion Aside from the apparently faulty date algorithm the program occurred because of insufficient validity checks on the data Guideline 2 5 3 2 states in part The requirements should specify that all incoming values are checked and that a response is provided for each out of range condition That all computed volume differences were zero should have been considered an out of range condition 65 0044 Rod Position Calculation Date 5 20 98 Source LER 368 1998 003 Domain Nuclear power Function Control element assembly position Guidelines 2 3 1 4 Description ANO 2 determined that the surveillance of Control Element Assembly CEA position was not being performed for one CEA group as required by Technical Specifications A software change was implemented in 1989 to create a report from the plant computer that calculated CEA position deviations to satisfy the requirement to verify each 12 hours that each CEA is within seven inches of all other CEAs in its group Errors in developing and implementing that change res
60. r Guidelines 2 2 1 Description On March 4 1998 at approximately 1600 hours with the reactor mode switch in the RUN position Nine Mile Point Unit 1 NMP1 exceeded 100 percent rated core thermal power and exceeded the power flow relationship of Technical Specification TS 3 1 7 d Specifically the eight hour average for reactor thermal power at 1600 hours read 1851 Megawatts Thermal MWt on the control room hourly typer which exceeded the licensed maximum power level of 1850 MWt Shift personnel failed to recognize that reactor power was at rated and increasing slowly during the shift due to the reactivity conditions of the core at this point in the operating cycle Investigation has determined that the thermal power limit had been exceeded on multiple previous occasions Shift average power computer point C873 is calculated by the process computer The computer extracts a value of instantaneous core thermal power computer point C875 once each 10 minutes starting at 0000 0800 and 1600 hours each day The computer then averages the C875 values to create C873 The C873 value is displayed on the hourly typer in the Trend 7 position It was determined that the 10 minute sampling interval did not provide sufficient accuracy Discussion Several means of determining thermal power are available to control room personnel the most accurate ones show fluctuations while the C873 computer point has a stable display and is also available in type
61. rder anyway and once it was in their system he would make sure that I was charged the right price It might take a day or two but he would make it right I told him to go ahead They let you track existing orders on their website Later that day the order was there showing a price of 100 00 The next day it still showed 100 00 The following day it showed 50 01 If you ve read this far I trust that you can figure out what must have happened Andrew Koenig ark research att com http www research att com info ark Discussion The requirements were not specific in that they permitted using gt rather than gt This failure is classified as an example of lack of specificity and completeness Guideline 2 3 4 1 15 0008 Pentium III Chip Flaw Date 08 29 00 Source Risks 21 04 Neumann 2001 Domain Hardware Function CPI Guidelines 2 5 2 1 Description New Pentium III chip recalled NewsScan newsscan Q newsscan com Tue 29 Aug 2000 09 45 34 0700 Intel is recalling its 1 3 gigahertz Pentium III chip which it has sold to only a handful of power users running advanced applications because a certain combination of data voltage and temperature conditions may cause the chip to fail The chip is expected to be back on the market in a couple of months Reuters cited in the Washington Post 29 Aug 2000 http www washingtonpost com wp dyn articles A40772 2000Aug29 html NewsScan Daily 29 August 2000
62. re Report No 0027 2 5 1 1 0015 TDWR Communication Failure 0019 Indianapolis ARTCC Failure 0035 2 5 1 2 0015 TDWR Communication Failure 0016 Weather Failure Due to Telco Circuits 2 5 2 1 0003 Pentagon Security Gate Malfunction Single Points of Failure and Backup Plans 747 400 Uncommanded Throttle Closure 0028 2 5 2 3 0009 i 0026 in Si 0030 i 0031 Security Computer Failure 2 5 2 7 0018 Weather Processor Crash 2 5 3 3 0028 0029 0041 Software Maintenance Problem 0043 Date Uncertainty 2 6 1 0001 Configuration Management on User 0016 Weather Failure Due to Telco Circuits 0017 0018 2 6 3 0014 0034 Snubber Inspection Scheduling 0036 Inspection Procedures 0038 Incomplete Surveillance Software 2 6 4 0020 0041 Software Maintenance Problem 0045 Reactor Power Calculation iL al NASDAQ Outage E i Pentium III Chip Flaw Le TDWR SW Failure Ls BOS ARTCC Outage prs 747 Problems NEAN Subway Doors 252 3 Train Door Failure EN Train Signal System Software ir 7477 Engine Shut Down 5 3 Subway Doors EE London Subway Doors E TDWR SW Failure EE Weather Processor Crash 263 TDWR Crash Failure 264 BOS ARTCC Problem 2 6 5 0010 Failures During Upgrades z 7 2 9 2 0024 A320 Article in Science amp Vie 0028 Subway Doors 0029 London Subway Doors 2 9 4 0005 UPS Backup Failure 2 9 8 0006 Saturn Limit Logic 9 10 0013 Electrostatic Discharge 3 Failure Descriptions This chapter p
63. resents the failure descriptions and the following additional information Date Source Domain Function Guidelines Description Discussion The date of the description or failure report not necessarily the date of the occurrence of the failure The source of the failure description LERs are identified by docket number year and report number The general application area of the failure aircraft ground transportation etc The function within the domain The applicable and relevant guidelines from the previous chapter A description of the failure as presented in its original source these descriptions have not been edited and sometimes take liberties with grammar and writing style A brief explanation of how proper application of the requirements guidelines might have prevented or mitigated the consequences of the failure 0001 Configuration Management on User Interface Date 09 19 2000 Source Risks 21 05 Neumann 2001 Domain HVAC Function Climate Control Guidelines 2 3 1 1 2 6 1 Description Computerized air conditioning risks Pere Camps pere O pere net gt Tue 19 Sep 2000 19 45 05 0100 BST We just moved offices this Monday to a brand new building and the air conditioning machines were working much too well we were freezing This surprised most of us as the new AC system was run by a PC It looked very robust After some debugging we found out that the control software was buggy We
64. risk What happened caused concern to the signalman But he stressed that the mechanical signal equipment and all other equipment worked normally bringing all trains to an immediate standstill after the problem was discovered The problem was caused by computer software fault in the signal box sic PM It gave the wrong indication to the signal man All the trains froze where they were The lights told him that something was different to what was happening outside 43 BR conceded that the faulty equipment served a vital function This little piece of software tells the signalman what is happening outside The software faults were found inside the panel in the train indicator box in a system responsible for operating the lights Alastair Wilson contracts and production director of E B Signal the manufacturers said The system is under test I do emphasize that things are going through a testing stage It is not unusual to have minor software bugs A spokesman for the National Union of Railwaymen said that any operational shutdown of train indicator screens would at best create a major disruption and at worst could create alarming safety hazards If everything goes to red it puts enormous pressures on an individual signalman Discussion The description shows that sensor data were not correctly processed at least under some conditions and that this led to incorrect information being displayed to the operator
65. rottle Guidelines 2 5 2 1 Description Boeing 747 400 Autothrottle problems Martyn Thomas mct praxis UUCP gt Wed 11 Apr 90 17 26 41 BST This week s Flight International reports British Airways BA Boeing 747 400s have experienced uncommanded inflight closure of all four throttles on six separate flights between 6 October 1989 and 19 February 1990 several times on one of those flights alone according to formal reports Several other airlines have suffered the same incident Northwest reporting it first In most of the events the power levers retarded rapidly to idle but sometimes the reduction was partial followed by automatic reset All incidents have occurred in the climb or cruise and an IAS of more than 280 knots is believed to be fundamental to the even Evidence indicates that the event is caused by a spurious signal to the full authority digital engine control from the stall management module The single word spurious command says that the undercarriage gear is down or the flaps are at setting 1 so if the IAS exceeds the maximum speed for these configurations the autothrottles close to reduce IAS to limiting speed then reset to maintain it The modification to correct the problem issued on February 22nd assumes that the fault was in the processing logic of the appropriate universal logic card a printed circuit software unit sic and adopts a standard technique for reducing digital oversensiti
66. rribilli after hosting a National Tree Day function He tried to get off a train about 2 40 pm just as the station guard was warning that the doors were closing and to stand clear But Mr Dee said the door was closing as the guard was speaking It knocked him backwards trapping his left foot below the knee inside the train and leaving his right leg dangling between the platform and the train wheels The force of the door closing knocked me off balance My left leg was trapped and my right foot was down near the wheels and I couldn t move I was so far down that I had to hold the door with my hand to steady myself he recalled yesterday Luckily there were two women inside the train They managed to open the door enough for me to get my left leg out but I was still trapped between the train and the platform Mr Dee said a fellow commuter saved him from being crushed by screaming out to platform staff to stop the train from moving He saved me The guard obviously couldn t see me If the train had moved off then I would have been dead it s as simple as that Mr Dee said he was worried about passenger safety during the Olympics You couldn t get a more pro public transport group than Planet Ark but there is something 17 blatantly wrong with the transport system he said There were no safety buttons in the carriage to warn staff or stop the train and there was no one on the platform to see me It was pure chance that the train
67. s of record on July 27 had the option of taking the new common or Class B stock plus 1 20 per share 2 a fraction of the new common stock that would be the equivalent of 20 or 3 a fraction of cash and fractional shares that would maintain their percentage ownership of all outstanding shares For the last two options the fraction of cash and fraction of shares depended on the total number of outstanding shares of the old company At the end of the exchange and disbursement the new company transformed back into the old company and trades on the NYSE as F The final numbers wound up such that if you took the full fractional new share with your matching full share you received an additional 0 748 share Tim Prodin and other readers of Risk Discussion The description of this failure emphasizes the effect rather than the cause However the title decimalization suggests that the requirements were formulated in true fractional form whereas the implementation used decimal fractions This aspect of the failure is classified as an example of incorrect functional requirements Guideline 2 1 3 There is also an indication that an inappropriate digital representation was used This aspect of the failure is classified as an example of requirements did not ensure that data types were appropriate for the variables Guideline 2 2 1 3 0003 Pentagon Security Gate Malfunction Date 08 05 00 Source Risks 21 05 Neumann 2001 Domain Real t
68. s not take into account the fact that the systems called classical are also subject to major innovations since they practically all require computer automation Discussion Spurious data indications by the flight warning computer may be due to lack of de bounce as described under Failure Description No 23 but in any case indicate that requirements for vital operator displays ignored essential characteristics This cause of failure is classified as an example of incomplete HCI requirements Guideline 2 9 2 The number and ordering of event notifications on the display obviously made the pilots task more difficult Warning displays should recognize that operators can only perform a limited number of actions and must prioritize the displays so that the most important actions will be taken first This cause of failure is classified as an example of event notification and display requirements inadequacies Guideline 2 9 1 The incorrect warning of the outage of automatic pitch trim caused the operators to take improper actions For vital indications there must be independent means of distinguishing between failures of the monitored system here flight controls and the monitoring system the flight warning computer This cause of failure is classified as an example of incorrect requirements for control and indication Guideline 2 1 3 40 0025 747 Problems Date 6 25 90 Source Risks 10 12 Neumann 2001 Domain Flight control Function Fl
69. sages at the same time the host was sending commands to also switch This worsened the queue buildup problem and is believed to have led to the abort 1107 1537Z Bus connector and interface cards were replaced to restore the CCU 3 LAN CCU 3 will remain out of the system until all testing has been successfully completed A post mortem report should be completed by 11 9 29 Discussion Technician action to reconfigure an air traffic control computer at the same time the system was trying to reconfigure itself exacerbated the problem This cause of failure is classified as an example of lack of requirements to address proper functionality of system to support maintenance actions Guideline 2 6 4 The communication errors in the channel from Nantucket were part of the initiating events This cause of failure is classified as an example of lack of requirements for exception handling in communication channels 2 5 2 1 Requirements for testing the software upgrade were also inadequate This cause of failure is classified as an example of lack of requirements for software upgrade support Guideline 2 6 5 30 0021 F 16 Weight on Wheels Source Neumann 1986 Domain Flight control Function Landing gear retraction Guidelines 2 3 1 6 Description During early flight testing one of the first things the Air Force test pilots tried was to tell the computer to raise the landing gear while standing still on the runway Guess what happened Scratc
70. t and overcrowding even where the rolling stock is new as it is on the lines from Peterborough and Cambridge into London King s Cross It was recognised at the enquiry into the Clapham rail disaster that a large proportion of the deaths and serious injuries in a crash can be attributed to passengers having to stand in the aisles between the seats Even a low speed impact means that standing passengers who insist on obeying Newton s first law of motion will continue their journey along the carriage until brought to rest by their fellow passengers or by the door to the adjoining carriage Even so it does not appear to be cost effective to supply adequate numbers of carriages to cope with the rush hour After all the management has to show a profit so that privatization will attract investors and a yearly season ticket between Stevenage and London only costs 1744 pounds sterling Another bit of cost cutting is to use driver only trains There is no guard to check the doors before the train pulls out This is so on most rail and underground services There is usually a TV monitor which the driver can use to check the length of the platform This does not seem to be particularly effective judging by the number of incidents I have personally witnessed over the last few years such as A driver closing the automatic doors and pulling away after a mother got out but before her children had time to leave the train Frantic waving and shouting by other
71. ty planning in rollback recovery Guideline 2 8 2 4 Even with the insufficient backup capacity the network could still have recovered much faster if requirements had called for subscribers to be notified of impending loss of service and of the expected recovery time This cause of the failure is classified as an example of inadequate match of recovery procedures with network characteristics Guideline 2 5 2 1 11 0005 UPS Backup Failure Date 10 12 000 Source Risks 21 10 Neumann 2001 Domain Hospital Function Uninterruptible power supply Guidelines 2 1 3 2 9 4 2 3 4 9 Description British newspapers today reported that a baby was born at Eastbourne General Hospital by caesarian section the operation being performed under torchlight following a power cut caused by a storm On one account the standby generators couldn t be started as the computer that controlled them believed they were already on and when main power was restored after twenty minutes it could not be switched through to the operating theatre as the computer believed that the generators were still running On another account the computer refused to believe that the power had gone off in the first place http www guardian co uk uk_news story 0 3604 381054 00 html The emergency lights above the operating table were not powerful enough for the doctor to work safely so he sent nurses running to get torches flashlights from wherever they could The nurses held the t
72. ugh comparison testing of the voltages and waveforms from the first UPM repaired Yes the facility has used the energized but offline systems as the test bed Discussion Requirements did not deal with detection of this correlated failure mechanism This cause of failure is classified as an example of lack of requirements for independence of failure detection and recovery mechanisms Guideline 2 4 2 The use of an energized system for testing by substitution represents a hardware analog to inadequate exception handling in software This cause of failure is classified as an example of inadequate requirements for exception handling Guideline 2 5 1 1 28 0020 Boston ARTCC Outage Date 11 13 00 Source AMBRIEFS FAA 2000 Domain Air traffic control Function En route Guidelines 2 6 4 2 5 2 1 2 6 5 Description DETAILS At 2 27 AM EST the installation of a Flight Data Input Output FDIO Electronic Equipment Modification EEM to add Central Control Unit CCU 3 was completed This EEM provides equipment diversity and required hardware and software changes to the FDIO and Central Computer Complex Host CCCH adaptation changes End to end testing was successfully completed At 5 30 AM the host was configured for daytime operation and error printouts started to appear indicating time message timeouts and undetermined errors for Nantucket ACK ATCT and Falmouth FMH TRACON At 1 38 PM EST the host experienced a slowdown of flight
73. ulted in Group P deviations being determined for each of the two sub groups but not for the entire group In the root cause evaluation it was noted that inconsistencies in documentation at the time this condition originated may have caused some individuals to conclude that each of the Group P sub groups constituted a separate group of CEAs and thereby have contributed to either the error or failure to detect the software change error Discussion The problem could have been avoided by application of Guideline 2 3 1 4 Functional Completeness of Software Requirements The guideline states in part All functions allocated to software from the system requirements document should be documented in the software requirements 66 0045 Reactor Power Calculation Date 12 16 99 Source LER 440 1999 007 Domain Nuclear Power Function Feedwater temperature compensation Guidelines 2 3 3 2 2 6 4 Description Personnel at the Perry Nuclear Power Plant discovered an error in the calculation of reactor thermal power A database that provides numeric input to thermal power calculations had been modified by setting specific inputs to zero This effectively removed the feedwater temperature compensation function from the Integrated Computer System producing non conservative values for reactor power The cause of the event was identified as program and process weakness in the development of software change Insufficient administrative contro
74. us the AFD monitor alarm had been inoperable The periodic AFD monitor alarm test procedure did not fully test all possible combinations of potential operating conditions The failure to perform the required more frequent AFD monitoring when the AFD monitor alarm was inoperable constitutes noncompliance with the TS The apparent cause of the event was that the subject Operations Surveillance Test procedures 1OST SA 1 and 2OST 5A 1 previously lacked the information necessary to successfully perform the task from its initial development Verification that two channels being out of the target band would cause the Axial Flux Difference monitor to alarm were not included in the surveillance procedure Discussion The problem could have been avoided by application of Guideline 2 3 1 4 Functional completeness of software requirements The guideline states in part All functions allocated to software from the system requirements document should be documented in the software requirements 62 0041 Software Maintenance Problem Date 7 31 00 Source LER 336 2000 013 Domain Nuclear Power Function Core Monitoring Program Guidelines 2 5 3 3 2 6 4 Description With the plant in Mode 1 at 100 power it was determined that the in core monitoring computer software program INPAX had not run the required calculation for azimuthal power tilt for a period exceeding 12 hours The surveillance requirement to calculate the tilt at least once per 12
75. vity there is now a delay a few microseconds built into the software by requiring it to receive an eight word command before acting Power spikes of other spurious commands should not produce a reaction So far the latest modification has proved effective Early corrections though had assumed the reaction was associated only with main gear selection so although software changes had reduced the incident rate spurious flap signals continued to set engines to idle BA has not reported any further events since 33 February Discussion The need to de bounce switch indications is widely recognized to mitigate the effects of spurious switch operation e g due to acceleration or electric transients that simulate switch closure A frequently used de bounce technique is to require that the signal be present for a given number of clock cycles before it is accepted as valid The cause of this failure is classified as an example of improper sensor data processing requirements Guideline 2 5 2 1 34 0024 A320 Article in Science amp Vie Date 6 2 90 Source Risks 10 02 Neumann 2001 Domain Flight control Function A320 Guidelines 2 9 2 2 9 1 2 1 3 Description This article appeared in the Aeronautique section of the French science magazine Science amp Vie in the April 1990 issue A rebuttal from Bernard Ziegler technical director of Airbus Industrie may be found in the following May issue LES CRI
76. was prevented from moving A spokesman for CityRail said both incidents were being investigated Discussion That the trains were allowed to move with doors sufficiently open to trap passengers indicates that requirements for sensor processing and their verification were inadequate This cause of failure is classified as an example of improper sensor data processing requirements Guideline 2 5 2 3 Safety considerations for public transport should preclude trains from moving with body parts protruding In terms of nuclear reactor safety this is a design basis event This aspect of the failure is classified as an example of incomplete with regard to design basis Guideline 2 1 1 18 0010 Failures During Upgrades Date 8 01 00 Source Risks 21 01 Neumann 2001 Domain Banking Function Customer interface Guidelines 2 7 2 2 6 5 Description Barclays Internet banking security glitch following software upgrade Pete Morgan Lucas pjml nsgmail nerc swindon ac uk gt Tue 1 Aug 2000 09 30 44 0100 BST Barclays Bank yesterday had a problem within their online banking service at least four customers found they could access details of other customers Barclays are claiming this to be an unforeseen side effect of a software upgrade over the weekend See http news bbc co uk hi english business newsid_860000 860104 stm for more details Pete Morgan Lucas NERC_ITSS Network Security NERC Swindon Also noted by AllyM