Home
Operating Instructions
Contents
1. 4X1 5V Alkaline AA LR6 Mignon Inserting Replacing the battery Open battery compartment lid 16 in the direction of the arrow insert new batteries as indicated by the symbol in the battery compartment Suitable rechargeable batteries can also be used LED display Yellow LED 12 low battery charge insert new battery Dispose of used batteries at suitable collection points not with household waste Remove the batteries if you do not intend to use the unit for some time Always use the centre of the laser line when marking and aligning Commissioning with levelling function Turn the laser casing to the working position Use the sliding switch 9 to switch on the laser unit Horizontal and vertical laser lines and the plumb line laser dot appear The LED lights up green The LAX goo is in Self levelling mode and levels itself automatically The laser lines flash if the laser unit is at too steep an angle The laser unit is outside the self levelling range and cannot level itself automatically Selecting the laser functions Once the unit has been switched on using the sliding switch 9 use button 11 to switch between the various laser functions Levelling functions 2 x vertical laser lines at a 90 angle 1X 360 horizontal laser line 1x plumb line function Plumb line laser function The plumb line dot will be clearly visible after the laser casing has been
2. 8 Precisely mark point D on the other wall or on the floor using the 90 laser line Note The distance from A to B B to C and B to D should be the same to guarantee accuracy 9 Turn the LAX 400 through 90 and align laser line 1 with point D 10 Mark position E on the perpendicular 2nd laser line as close as possible to point A 11 Measure the distance between points A E Room length or Maximum permissible distance between distance between points A and C points A and E 10 m 3 0 mm 20m 6 0 mm 32710 1 8 65 8 1 4 LAX 400 Technical data Certificate of warranty for STABILA LAX 400 Laser type Red diode laser pulsed line laser Cuciomce wave length 635 nm Power output lt 1 mW laser class 2 in accordance with IEC 60825 1 2007 This product compl with the appl requ of 21CFR parts 1040 10 and 1040 11 Self levelling range approx 4 Address Levelling precision Horizontal laser line 0 3mm m 3 8 over 00ft centre of laser line Laser line inclination 0 2mm m 1 4 over 00ft laser line 90 precision 0 3mm m 3 8 over 100 ft Vertical intersection 0 3mm m 3 8 over 100 ft Plumb line beam facing downwards 0 3mm m 3 8 over 1oo ft Batteries 4x1 5 V alkaline size Mignon AA LR6 Date of purchase Operating life approx 10 hours alkaline Operating temperature range 10 Cto 50 C 14 F to 122 F Storage temperature range 25 C to
3. laser unit so that it is directly in front of wall B Align the LAX 400 with wall B using the same exit window for a vertical laser line 8 Move the laser line cross by turning and adjusting the height until it precisely coincides with point 2 9 Turn the LAX 400 round 180 and align with wall A using the same vertical laser line exit window Do not adjust the height 10 Move the laser line cross by turning the casing until it precisely coincides with the marking line of point 1 11 Once automatic levelling has ended mark the cross projected onto wall A Point 3 12 Measure the vertical distance between points 1 and 3 Perform this check with both vertical laser lines B Distance S to the wall Maximum permissible distance 5 m 3 0 mm 10 m 6 0 mm 15m 9 0mm 16 5 1 8 32710 1 4 493 3 8 C B gt 5 m gt 5 m A a165 2165 7 10 m 32 10 ___ Angle check Checking the 90 angle 1 Mark point A on the floor at a distance of 10 m 32 10 in a sufficiently large corner of the room 2 Align the LAX 400 with point A using the plumb line dot 3 Align the LAX 4oo with the one wall using a laser line 4 Precisely mark point B on the floor at the halfway point 5 Precisely mark point C on the wall or floor 6 Shift the LAX 400 and align with point B using the plumb line dot 7 Align the LAX 400 with point C again using the laser line
4. pushed up and the feet spread apart 7 This can be used to position the LAX 400 precisely Commissioning without levelling function Only use the button 11 to switch on the LAX goo in Marking function mode The horizontal and vertical laser lines plumb line dot and LED flash quickly The LAX 400 is not in self levelling mode and can only be used in this mode for marking and alignment Marking functions 2 x vertical laser lines at a 90 angle 1 xX 360 laser line 1 x dot laser Additional functions Function Height adjustment Use the clamping lever 4 to adjust the height of the laser casing Function Fine adjustment Use the fine adjustment 2 to rotate the laser casing to an exceptionally high degree of precision which allows the vertical lines to be precisely aligned Checking the accuracy The LAX 400 multi line laser is designed for use on building sites and is perfectly adjusted before leaving our premises Regularly check the calibration of the accuracy as is the case with all precision instruments Always check the unit before starting work especially if it has been exposed to heavy vibrations e Vertical check e Horizontal check e Angle check ssCRECKEECECCECOCOCRCCoCOCCCe Vertical check Checking the 2 vertical laser lines 1 Create a reference line e g with a plumb line 2 Set up and align the LAX 400 at distance Y in front of this reference line 3 Compare the lase
5. source and unauthorised modifications of the unit by the buyer or a third party shall invalidate the warranty STABILA does not provide a warranty for natural signs of wear and minor defects that do Do not use in explosive or corrosive environments not affect the operation of the unit Any warranty claims should be made through your Do not dispose of the batteries and unit with domestic waste dealer and be accompanied by your sales receipt completed certificate of warranty See last page of operating instructions and the unit itself Always check before you start work that the unit is functioning correctly and accurately especially if it has been exposed to heavy vibrations Keep this user manual in a safe place and hand it over when passing the unit to another person LAX 400 Components of the unit Laser casing Fine adjustment Casing frame Height adjustment clamping lever Magnet Eyelets for attaching tensioning belt Feet with bearing surfaces 5 8 tripod socket 0 ON AWM FWN HH ON OFF sliding switch with transport lock ON OFF button for marking laser e e e O Button for selecting laser functions m N Green LED Operating function Yellow LED Battery charge indicator 13 Exit window for 360 laser line 14 Exit windows for vertical laser lines Exit window for plumb line laser Battery compartment lid moO h h h b G A A G G ie TAA
6. 70 C 13 F to 158 F Subject to technical modifications Dealer stamp signature when operated within the specified temperature range STABILA Messgerate Gustav Ullrich GmbH P O Box 13 40 D 76851 Annweiler Landauer Str 45 D 76855 Annweiler Tel 49 6346 309 0 Fax 49 6346 309 480 e mail info stabila de www stabila de STABILA Inc 332 Industrial Drive South Elgin IL 60177 1 800 869 7460 STABILA Ma www stabila com
7. Operating Instructions anna LASER RADIATION DO NOT STARE INTO BEAM n LASER CLASS 2 Fe Gea IEC 60825 1 2007 STABILA My Laser LAX 400 AARAA AAA VV VV VY ALA AMM k aA iY hihi Os G a vee LAX 400 Operating Instructions The STABILA LAX 400 is an easy to operate self levelling multi line laser designed for use on building sites The laser unit is self levelling within the range of 4 The fine adjustment allows precise 90 angles to be projected The laser lines are pulsed which makes it possible to work over greater distances using a special STABILA line receiver For more information refer to the operating instructions for the line receiver If you still have questions after reading through the operating instructions you can obtain advice by telephone wy 0049 63 46 309 0 Functions 2 x vertical laser lines at a 90 angle 2 x cross lines 1X 360 horizontal laser line 1x plumb line laser HUN gt Bu a All Attach the warning label in your language to the laser unit Affix the adhesive label over the English text The relevant adhesive labels are enclosed RADIATION LASER NE FIXER JAMAIS LE FAISCEAU LASER CLASSE 2 Before initial commissioning e Attach the warning label in your language to the laser unit e Read the safety instructions gt Safety instructions e Insert batteries gt Battery replace
8. ment LAX 400 en Safety instructions Maintenance and upkeep The STABILA laser measuring unit is an optical precision instrument and should therefore be handled with care Window apertures display windows a er Dirty window glass impairs the optical function Only permit qualified persons to operate the unit Only clean with a soft cloth a little water or if required a mild detergent Observe the safety precautions Before initial commissioning Carefully read the safety instructions and operating instructions Attach the warning label in your language to the laser unit The relevant Casing adhesive labels are enclosed The positioning of the labels is described Clean the unit with a damp cloth in the operating instructions Do not use solvents or thinners Do not immerse the unit in water CAUTION Do not unscrew the laser unit LASER RADIATION Da Ata Transport and storage 630nm 660nm lt 1mW Remove the batteries if you do not intend to use the unit for CLASS II LASER PRODUCT CFR 1040 10 AND 104011 CFR some time IEC 60825 1 2007 i Warning Do not store the unit when damp Your eyes are normally protected by their lid closure reflex and ora natural instinct to turn away if you accidentally look into the laser beam of class 2 laser units very briefly If a laser beam hits your eye consciously close your eyes and move your head out of the path of the Recycling programme f
9. or our EU customers FB Allow the unit and carry case to dry first if necessary nee look into We ee ice ce ati th In accordance with WEEE rules STABILA offers to dispose of electronic products e aser goggles available with laser units are not protective goggles rather ae heenda therusetilsericalie allow the laser light to be seen more easily For more information call 0049 6346 309 0 Do not aim the laser beam directly at people Avoid dazzling other people Keep out of the reach of children Declaration of warranty by STABILA Laser In addition to the statutory rights of buyers which are not limited by this warranty STABILA guarantees that the unit is free from defects and has assured features in the event of material or manufacturing defects for a period of 24 months from the date of It can result in dangerous exposure to radiation if operating and adjustment equipment or methods other than those described in these operating instructions are used ERS a purchase Any defects errors will be remedied at our discretion through reworking Tampering modifications with the laser unit is not permitted or replacement STABILA will not assume liability for further claims Defects resulting The unit may malfunction if it is dropped or suffers serious vibrations from improper handling e g damage due to application of serious force operation with incorrect voltage current type use of unsuitable power
10. r line with the reference line 4 Do not allow the laser line to deviate from the reference line by more than 1 mm 11 256 over a distance of 2m 7 1 5 Perform this check for both vertical laser lines Checking the plumb line function 1 Align the LAX 400 precisely with one floor marking using the plumb dot 2 The projected laser line cross appears on the ceiling 3 Turn the LAX 400 around 180 and align it once again with the floor marking using the plumb line dot 4 The projected laser line cross appears on the ceiling 5 The difference measured between the markings is twice the actual discrepancy With a ceiling height of c m 16 5 the difference should be no more than 3 mm 1 8 Horizontal check Checking the level of the horizontal laser line 2 parallel walls at a distance S of at least 5 m 16 5 apart are needed to carry out the horizontal check 1 Position the LAX 400 as close as possible to wall A on a horizontal surface 2 Use an exit window for a vertical laser line to align the LAX 400 with wall A 3 Switch on the laser unit sliding switch 9 4 Once automatic levelling has ended mark the cross projected onto wall A Point 1 5 Turn the LAX 400 around 180 and align with wall B using the same vertical laser line exit window Do not adjust the height 6 Once automatic levelling has ended mark the cross projected onto wall B Point 2 7 Now reposition the