Home
CS-100 User Manual V1.4
Contents
1. USER MANUAL Rev 1 4 Fused Battery for Time 12VDC OUT Clock Connector 12VDC Internal Power Supply Charging Status AC 80 260V IN Connector Protection Fuse for Output Relay Input AC Power 120V Battery Back up Connector Insert SIM Here PC Programming Connector Power Indicator Output Relay Terminal Rated at 10 amps 120V Requirements A mobile phone SIM card with sufficient credit to send confirmation text messages when programming the CELL SWITCH MODEL CS 100 unit It is our recommendation to utilize a T Mobile SIM card with unlimited nationwide messaging If the unit did not arrive preloaded with a SIM Card it is important to follow the following step SIM Card Configuration You must remove the PIN request from the SIM before inserting it in the unit otherwise the device will not work This can be done either by the provider or simply insert the SIM in a T Mobile phone and disable the PIN Request and the Voicemail function It is important to make sure that the voicemail does not pick up the call Cell Switch USER MANUAL Rev 1 4 Installation To install the CELL SWITCH MODEL CS 100 you will need to mount the unit within the close proximity of a 120V power supply and the device you wish to control The CELL SWITCH MODEL CS 100 comes with its own 12 Volt Amp Internal Power Supply all mounted in an IP65 Enclosure and rated for indoor our exterior applications T
2. PSSW54321 RLYP ON and the unit will return the following SMS Text Message RELAY P ON To latch the relay permanently back OFF you would send the following SMS text command to the unit PSSW54321 RLYP OFF and the unit will return the following SMS Text Message RELAY P OFF If you need to check the status the Relay and what mode it is you can send a SMS Text request using the following command PSSW54321 RLY And the unit will return the following SMS Text Message Example assuming Relay is still part active after programming to be on for 2 hours and 1 hour remaining RELAY ON 03600 If the relay has been programmed as permanently on the unit will return the following S M S Text message RELAY ON P If the Relay is inactive the unit will return the following SMS Text message RELAY OFF SMS Report after latching the unit by calling the unit It is possible to receive a text message whenever the Relay is latched via Phone Call which will report both Relay On and Relay Off to the user that has call the unit and only practical for certain infrequent applications and the factory default for this function is off To enable this function you would send the following SMS text message to the unit PSSW54321 RLYM ON and the unit will return the following SMS Text message RLYM ON and the unit will return both Relay On and Relay Off status SMS Text messages when called To turn this function off you would send the followin
3. lS IK Cell Switch ED T Automation Gone Cellular Model CS 100 User Manual A product of IE SCM Technoloaies gt P O Box 33157 Cleveland Ohio 44212 www cell switch com x a Model CS 100 BERTI Cell Switch Model CS 100 Remote Controller User Manual IMPORTANT Please read through the instruction manual before you start to install and program the device If you are unsure how to connect the device you wish to control please refer to a qualified person Description The CELL SWITCH MODEL CS 100 is to be a versatile option as a Single Output Relay system with normally open and closed contacts to provide a low cost solution for a wide range of applications only requiring a simple on off command It is activated by calling its cell phone number and it will reject the call without answering and switch on the device connected to it There is no call costs incurred when dialing the unit and it will only recognize an authorized telephone number calling it and reject unauthorized callers the call without answering The system has the capability to load up to 25 numbers in the white list as authorized users and the single output relay can be programmed to switch on for a pre determined length of time whenever the CELL SWITCH MODEL CS 100 is called alternatively the output relay can be permanently switched on or off by sending the CELL SWITCH MODEL CS 100 a text message Cell Switch
4. number of the SIM card installed in the CELL SWITCH MODEL CS 100 The password command must pre fix all SMS text commands it is recommended the default password be changed Remember that all SMS text commands must always be sent in CAPITAL LETTERS DO NOT add spaces or any other characters otherwise the system will simply ignore the commands Programming Commands The CELL SWITCH MODEL CS 100 is pre programmed and controlled by sending certain SMS Text Messaging to the unit and is password protected with a factory default setting of five digits preset at PSSW12345 and this prefixes any commands to the unit Changing the Password It is possible to Change this password to another 5 digit number by sending the following SMS Text message to the unit and we assume the new Password is 54321 PSSW12345 NPW 54321 You will receive the following message back from the unit to confirm the password has been changed NPW 54321 The new password is now PSSW54321 Checking Signal Strength PSSW SGH The system will now send back a report to indicate the Signal Strength at the location of the CELL SWITCH MODEL CS 100 and you will receive a similar message as follows SIGNAL STRENGH 14 which indicates a mid range of Signal Strength and is acceptable to maintain a constant network as the networks will vary and can drop as low as 5 and any lower the unit can well log off the network and Latch off the Relay if active and give the ind
5. SSW54321 RESET and the unit will return the following SMS Text Message UNIT RESET Warning This command will reset the password to PSSW12345 and the reset the output latch time to 1 second and completely wipe the numbers stored with the memory of the system Cell Switch USER MANUAL Rev 1 4 Specifications Model Operating Voltage Operating Current Relay Connections Relay Contacts GSM Frequency MHz Humidity Operating Temperature Physical size Protection Weight Approvals CELL SWITCH MODEL CS 100 12 or 24V DC Maximum 500mA typically 55mA Normally Open Normally Closed amp Common Contacts NC 10A 120VAC 28VDC NO 20A 120VAC 28VDC GSM850 GSM900 GSM1800 GSM1900 Less than 80 RH 20 C to 55 C 157 x 90 x 60 mm IP65 800 Grams C E
6. et to latch the relay for a period on 1 second and to change this latching period time to say 1 hour you would use the following programming command which is always calculated in seconds with 5 digits and therefore the command would be sent as 03600 To pre program to unit to latch the relay for 1 hour when called you would send the following SMS Text message to the unit using the new password PSSW54321 PSSW54321 RLY 03600 and the unit will return the following SMS Text Message RELAY SET 03600 and the Relay of the unit will now latch for one hour whenever the unit is called Subject to authorization of the number if Security Mode Set In addition to the pre programmed latching time when the unit is called it is also possible to temporary or permanently latches the Relay via SMS Text message without affecting the existing programming function when the unit is called If it is required to latch the relay temporarily for say 2 hours you would use the following SMS text command and again based on seconds PSSW54321 RLYT 07200 and the unit will return the following SMS Text Message RELAY TEMP 07200 and the relay has been temporarily latched for 2 hours as set in seconds If you require to latch the Relay permanently ON and back OFF again this can be done by using the following SMS Text commands Cell Switch USER MANUAL Rev 1 4 To latch the relay permanently ON you would send the following SMS text command to the unit
7. examples of numbers based on using the last 7 digits of the number PSSW54321 CLD0O1 1212121 CLD02 1313131 CLD03 1414141 CLD04 1515151 CLD05 1616161 and the unit will return the following SMS Text Message CLDO1 1212121 CLDO2 1313131 CLD03 1414141 CLD04 1515151 CLDO5 1616161 END Please note that you can 5 telephone numbers into the system using the same SMS text command only for up to the first 25 authorized users If you wish to just replace a number you can just replace say number 6 in the list by sending the following SMS Text command Cell Switch USER MANUAL Rev 1 4 PSSW54321 CLD06 156561 and the unit will return the following SMS Text Message CLDO6 1561561 and the previous number 1717171 has been replaced with 1561561 If the list number is more than 25 you can only program individual telephone number in 1 text message like the below example PSSW54321 CLD26 1735399 If the list number goes above 100 you would send the text command like the following example PSSW54321 CLD100 1324590 If you require checking or confirming what numbers are in the Authorized List you can either request all of the numbers in the list or request any particular one number in the list To request a single number stored you would send the following SMS Text Message to the unit PSSW54321 CLDOS And the unit will return the following similar SMS Text Message CLDO5 1616161 Setting the Security Mode Once all the telephone nu
8. g SMS Text Message to the unit Cell Switch USER MANUAL Rev 1 4 PSSW54321 RLYM OFF and the unit will return the following SMS Text Message RLYM OFF and this function is now disabled Programming in the administrator number in the system It is possible to program 1 administrator number into the system that will be recognized as authorized number that have programming access to the system as well as activate the device it is connected to To add 09876543210 as the administrator you would send the following SMS text message to the unit PSSW54321 ADM1 09876543210 Programming in the authorized telephone numbers in the system It is possible to program up to 250 Land line or Mobile Phone Numbers into the system that will be recognized as authorized numbers that can access the system and activate the Device it is connected to All telephone numbers can be programmed into the system using only the 7 digits of the telephone number as the system will scan the numbers of the last digits and accept and authorize that number to allow access to the system and will then reject the incoming call and activate the Relay as set and operate the device it is connected to Any Unauthorized numbers calling the unit will result in the system rejecting the call and refusing access to the system It is Possible to program up to 5 telephone numbers into the system using the same SMS Text command and you would use the following command to enter the first 5
9. he unit is supplied with a 10 amp rated plug to enable the easy connection to appliances Once you have installed the CELL SWITCH MODEL CS 100 and make the required connections to the device to be controlled the SIM Card can now be Installed in the Holder as described in the schematic drawing and the Power Supply connected and Switched on The Signal Led Green on the board will oscillate infrequently until it finds and logs on to the Network and will then flash every 3 seconds constantly and if does not happen then the unit has not logged on and it may be required to use an extension antennae or alternative network provider Once the system has logged on the Network the first thing you need to establish is the actual Signal Strength of the Location of the Installation to secure a constant signal strength for the reliability of the CELL SWITCH MODEL CS 100 and this can be done by simply sending the following SMS Text message to the unit PSSW SGH The system will now send back a report to indicate the Signal Strength at the location of the CELL SWITCH MODEL CS 100 and you will receive a similar message as follows The Signal Strength range can typically vary from 3 31 of which it is suggested that a consistent Signal Strength acceptable should be at least 12 and above as the signal network strengths can vary dramatically Connection Details The unit is shipped prewired as a normally open contact this means that when the relay i
10. ication that the unit is faulty when it is only subject to no Signal Strength In this instant the unit will consistently search and communicate with the network until it have re established a network link and log back on If this happens on a regular basis it is suggested you install an additional External Antenna Cell Switch USER MANUAL Rev 1 4 Output Relay Latch Time when called The CELL SWITCH MODEL CS 100 can be programmed to latch the Relay from a period of from 1 second up to 12 hours when called and this allows a vast range of flexibility for many applications from Automatic gates to switching on heating and lighting and remote re setting of servers etc This function can be operated in two modes of security which can be set as desired and the factory default is Open Mode meaning any person who has access to the actual SIM Card telephone number of the unit can operate the system and this is usually only used for setting up the system or for low security applications based on applications of convenience The other mode of operation is the Security Mode which only allows the persons who have their telephone numbers entered into the security list of the unit to access the system and this is usually also done once all the pre programming of the telephone numbers has been programmed into the system and the Latch times set For additional information see Setting Security Mode below The CELL SWITCH MODEL CS 100 comes pres
11. mbers have been programmed into the system you can now set the Security Mode and to program this you would send the following SMS Text message to unit PSSW54321 SSM ON and the unit will return the following SMS Text Message SSM ON and the Security Mode is on To set the system back to Open Mode you would send the following SMS text message to the unit PSSW54321 SSM OFF and the unit will return the following SMS Text Message SSM OFF and the Open Mode has been set to factory default Cell Switch USER MANUAL Rev 1 4 Setting the Operating Time for Output relay The system has the function to activate the output relay up to twice a day at a programmable time To program the operating time for output relay you would send the following text command to the unit PSSW54321 SMW SS MM HH TTT G SS is a 2 digits value stand for seconds MM is a 2 digits value stands for minutes HH is a 2 digits value stand for hours TTT is a 3 digits value stand for Turn ON time in seconds G stands for Group Time Section number 1 2 For example assume that you want the output relay to turn on for 20 seconds at 8 30am you would send the following SMS message to the unit PSSW54321 SMW 00 30 08 020 1 The unit will return the following SMS Text Message SMW 00 30 08 020 1 For example assume that you want the output relay to turn on for 100 seconds at 6 00pm for the second time section you would send the following SMS
12. message to the unit PSSW54321 SMW 00 00 18 100 2 The unit will return the following SMS Text Message SMW 00 00 18 100 2 Setting the Time Clock To set the time you can send the following SMS command to the unit The time must enter in 24 Hour format PSSW54321 TSET SS MM HH SS is a 2 digits value stand for seconds MM is a 2 digits value stands for minutes HH is a 2 digits value stand for hours For example to set the time 8 00am you would send PSSW54321 TSET 00 00 08 to the unit and the unit will return the following SMS text message TSET 00 00 08 Cell Switch USER MANUAL Rev 1 4 To check the time clock you may send text command PSSW54321 TREAD to the unit and the unit will return the following SMS text message The time is SSMMHH 00 00 08 Power Down Alarm The system has the function to send a text alert in the event the main power is lost and the system is relying on battery backup When power failure you would receive the following text message from the unit POWER DOWN When power restored you would receive the following text message from the unit POWER RESTORED Battery low Alarm The system has the function to send a text alert in the event the battery is running low You would receive the following text message from the unit when battery low Battery low voltage Reset the CELL SWITCH MODEL CS 100 To reset the system to factory default you would send the following SMS Text message to the unit P
13. s activated the device that is connected the unit will be turned on If for some reason you would like the device to be on all the time then the unit should be wired as normally closed The wire on J5 Pin 6 should be moved to J5 Pin 4 Warning The unit should be unplugged before opening the cover and making any changes If you are unsure how to connect the device you wish to control please refer to a qualified person Cell Switch USER MANUAL Rev 1 4 Gm mim G L N NC C NO Earth Line Neutral AC 120V Power Output Relay Rated Input 10 amps 120 volts Port Descriptions Earth GND Line L Supply AC Power 120V to the unit Neutral N NORMALLY CLOSED N C COMMON COM OUTPUT RELAY 10 amps 120 volts Max NORMALLY OPENED N O au RUN HM Example Connections A heater connected to output relay When the CELL SWITCH MODEL CS 100 is activated the relay contact will EH switch from the NC position to the NO position thus making the circuit and the NC C NO heater will be switched on 120VAC Output Relay Factory Default Settings The default settings are open access mode the default password is 12345 Any call to the CELL SWITCH MODEL CS 100 will activate the unit Cell Switch USER MANUAL Rev 1 4 Programming the CELL SWITCH MODEL CS 100 The CELL SWITCH MODEL CS 100 is programmed by sending it SMS text commands from a mobile phone these are sent to the telephone