FBI XL 1219 Manual - Ackerman Security
Contents
1. To Program User 1 s Arm Disarm Code 4 Press Code Key 2 Press number then the 4 Digit FALLBACK CODE 3 Press again The Zone 1 Green Light will blink slowly e Now Press Any 4 Numbers Desired For User 1 s Code Do not use 9 Upon completion of the 4th digit the zone 1 light will stop blinking i 4 Test the new code by attempting to arm the system NOTE Remember to DISARM the system before attempting to pro gram any additional codes 1 Press e Code key 2 Enter your New User 1 Authorization Code 3 Press 2 The Zone 1 Green Light Will plink slowly e Now press the 4 Numbers Desired for User 2 s Code Do not ust Upon completion of the 4th digit the Zone 1 light will stop blinking I Repeat for User 3 7 and 0 User O s Code may be programmed exactly as all other user codes only if the keypad AMBUSH feature is not used This feature is pre set by your installing company if desired See explanation of AMBUSH below Ambush is a 4 digit code that will either turn the system ON if it is off AMBUSH or OFF if it is on AT THE SAME TIME it will send a SILENT EMERGENCY SIG NAL to the central monitoring station The Ambush Code is pro grammed as User 0 following standard USER CODE PROGRAMMING as described on page 5 User 1 can erase any user s Code except his own as follows 1 Press Code Key 2 Enter User 1 Code 3 Press User Number of Code to be Erased e g if User
2. THE USER FRIENDLY XL1219R Total Control at Your Fingertips USER S GUIDE TO OPERATION and PROGRAMMING XL1219 USER S GUIDE INTRODUCTION The brain of your new security system is the XL1219 Control Panel All of the detection devices of your system are wired to the control panel When a violation occurs the control panel reacts by setting the appropriate devices into action It may cause a siren to sound transmit a coded signal to the central staton cause keypad lights to blink etc The XL1219 Digital Keypad will tell you the status of your security system at all times The following pages will familiarize you with the simple operation of the system via the Digital Keypad and will explain the meanings of the lights and buzzer TABLE OF CONTENTS Operation page arming the System ccc eee cece cee eee eee eenee 4 instant home feature 6 cece cee ee et teens 4 disarming the System 0 2 6 cece eee eee eee eee ees 4 ZOMG BYDES ass NE eae PS PRAGA Aten a eee da wane 2 zone reactivation unbypass 6 kee cece tee eee ene 2 keypad lighis os cece cade ee heehee shee ee Lea babe aas 3 keypad DUET ioei eiat des ned ae ew eB Pak eh Oe ER eS 4 panic installer pre set option 6 eee eee eee 4 Ambush installer pre set Option eee cece cece eee eee 4 Programming falIDACK CdS i e drer Fa allies ne SERENE uta ae EEEE 5 SETS GEIMEG 5 a4 ices r SES ER
3. 2 Code is to be erased depress only the number to erase entire code 4 Press Reset Key Repeat Steps 1 2 and 3 above entering User Number of code to be CHANGING changed in Step 3 A USER CODE 4 Enter new 4 digit code desired do not use 9 The exit and entrance delay times have been previously set for your EXIT and convenience and security These allow you to enter or leave the ENTRY DELAY premises through specified Delay Openings while the system is TIMES armed if you feel these delay times are unsatisfactory call your installing company ABOUT THE MANUFACTURER Your new XL1219 Control Panel and Remote Digital Keypad are manufactured by Fire Burglary Instruments Inc leading manufacturers of quality reliable security control equipment since 1971 These products have been engineered using the latest advances in electronic and Computer technology and are thoroughly tested by Computer as well as quality control experts several times during the manufacturing process Fire Burglary Instruments warranties its products through your installing company Product Reliability and Ease of Operation are two of the major factors in the engineering design of all of Fire Burglary Instruments products so you can look forward to many years of trouble free service from your new security system If you have any questions about the operation of your system call your installer Se i Rt SR NN RE nn m OCT 8
4. 5 12158 Printed in U S A
5. AMBUSH CODE for User 0 os programming Ambush Code p 6 pre set option To send an ambush signal 1 Enter your User 0 5 Digit Ambush Code amp Example 0 6 4 3 7 or 2 Enter any other user 1 7 plus User O s 4 Digit Ambush Code lt Example 2 6 4 3 7 NOTE If Ambush is not used your user 0 code will function like all other user arm disarm codes USER CODE USERS 2 7 amp 0 KEYPAD PROGRAMMING Your system is preprogrammed with a FALLBACK ARM DISARM CODE Be sure to record this code In the event of a total loss of power AC and battery all codes with be erased Your Fallback code will enable you to arm and disarm the system and re program your personal secret code As many as eight separate arm disarm codes can be programmed Each code must begin with a different digit which we call the User Number for example User 1 s arm disarm code would be 1 and any four additional numbers User 2 s code would be 2 and any four additional numbers etc It is not necessary to program all eight codes A user Code may be programmed for temporary use for a service person guest etc and then erased see below when no longer needed This maintains the secrecy of your regularly used codes ON THE SYSTEM MUST BE IN A DISARMED MODE TO ACCOMPLISH ANY PROGRAMMING ALL PROGRAMMING IS DONE USING 1 s CODE functions as an authorization code THE NUMBER 9 MAY NOT BE USED IN ANY CODE
6. E 2 Gide Leese eels Borat 5 arm disarm codes cece cece cece vee e eee eraneeeees 5 OMBUSA COJO seire reg twee gw als oa ods Pains aoe Fee eS 6 erasing A COMES aces Misia eadid cies a e end ware aie 6 CHANGING A code oai nen e gees oleae See Coane Wie ele ss 6 exit and entry delay rss udst ccc cece eee RES ed 6 ARM DISARM OPERATION To arm your security system with no zones bypassed 1 Make sure that all of the Zone Status green lights are lit If any of the green lights are off the number will show you which zone has an open loop open window etc You cannot arm the system with an open loop Once all protected openings are secured 2 Enter your 5 digit secret code by gently depressing each number key until you hear a momentary beep 3 When all 5 digits have been entered the red ARM light will go on and all of the green zone lights will go off You now have a pre set amount of time exit delay time to leave the premises through a door designated by your installer as a delay zone NV Nee os If you are staying within the premises and no one is expected to return while the system is ARMED you will want your time delay doors to report an Alarm instantly This is accomplished by selecting Instant Home Feature the INSTANT option To select the Instant option 1 Arm the system 2 Press 3 The zone 1 green light will go on NOTE This option automaticall
7. assed zones are automatically reactivated unbypassed when the system is disarmed However AFTER A BURGLARY ALARM you must manually unbypass any bypassed zones KEYPAD LIGHTS Each green light corresponds to a particular zone number 1 6 Each may be on steady blinking or off at various times indicating different conditions of the zone Since your security system has been customized to suit your specific needs your installer will identify any 24 hour zones in your system The chart below shows the meaning of the green lights Green Zone Lights Burglary Zones ZONE STATUS SYSTEM DISARMED SYSTEM ARMED Good ish of Light Off Fast Blink Bypassed Slow Blink ieee EEN To stop blink disarm system then press 7 Reset O 24 Hour Zones Each amber light monitors a particular function of your security system and is labelled accordingly If the function is operating normally the light is on AC light off the main electrical power supply is off FIRE light off trouble in the fire circuit BATCTERY Y light off low battery back up power supply Amber Status Light Light off System Disarmed Red Light on System Armed sg Arm Slow blink Central Station did not receive transmission Light Fast blink Alarm condition 4476 stop blink press Reset To stop blink disarm system then press Reset O THE KEYPAD BUZZER At the same ti
8. me that any of the AMBER LIGHTS go off to indicate a system problem a trouble buzzer may sound Installer option Buzzer To silence the trouble buzzer aa ci Press 7 ass Bypass 2 Press 0 Trouble Zone NOTE Remember to unbypass the trouble buzzer after the problem has been corrected This is accomplished by repeating steps 1 and 2 above A MOMENTARY BEEP occurs whenever a key is depressed indicating that the system has received the number you have entered e Approximately 7 to 10 CONTINUOUS BEEPS is verification that your system has successfully reached the central monitoring station with a signal Buzzer e STEADY BUZZING is a reminder to DISARM your system after entering the premises through one of the predetermined exit and entry zones _ OPTIONAL DIGITAL KEYPAD FUNCTIONS If your system has been designed to incorporate the panic option it will send a signal to the central station and may or may not sound an alarm at your premises depending on the option you selected PANIC installer pre set option To send a panic signal 1 Press and simultaneously for approximately 2 second Saree NOTE If silent panic was selected you will not receive the verifi cation buzzer 2 To reset audible panic press EJE for about second AMBUSH If your system has been designed to incorporate the ambush installer option you will program a special
9. y resets when the system is disarmed To disarm your security system 1 Enter your 5 digit secret code 2 The red ARM light will go off Zone Bypass Zone Reactivation Unbypass Unbypass Installer Pre set Option If you wish to arm only a part of your system such as the front doors and windows but still have the freedom to come and go for in stance through the back door you may bypass the desired zone s and then arm the rest of the system To bypass one or more zones 1 Make sure that the system is disarmed red light off 2 Press a l eves 3 Press the number of the zone to be bypassed Example To bypass zone 3 Press 9 then 4 The green zone light will blink slowly to indicate that that zone is bypassed NOTE To bypass additional zones repeat steps 2 and 3 above 5 Now arm the system by entering your 5 digit code All of the green lights will go off the red light will go on NOTE This option automatically resets when the system is disarmed To Unbypass a single zone 1 System must be disarmed 2 Press 9 3 Press number of the zone to be unbypassed 4 The green zone light should stop blinking OR To Unbypass all bypassed zones 1 System must be disarmed 2 Press C Reset If your system includes the auto unbypass optional function it will not be necessary to manually reactivate the zones as described above Under normal conditions byp
Download Pdf Manuals
Related Search
Related Contents
HYDRO POWER UNIT 3 Cellular Line Clear Music Mic Solar Inverter SI 5000 GUIDE RYTHMES - Lettre d`informations - SE-Unsa Gigaset SL400 (franᅵais) 0.29 MB (AM_20186_BA_Eurotops_FRA_01) Electrolux EI24BC10QS Owner's Guide E-286 - Renner Coatings 1well セルロース User Manual of SST-1200 GPS Time Synchronization System Copyright © All rights reserved.