Home

NS-100W Install Sheet

image

Contents

1. 6 minutes in one hour Troubleshooting Guide for height adjustable table The table does not work Check the mains plug is it switched on Check the supply cable is it connected to the control box Check the control box are the cables connected Check the control panel are the cables connected 199 Check that all cables are firmly connected Check cables are they cut or disconnected Check mains fuses are they serviceable Contact Ergomat A S for service The table height adjustment function is out of control Cut supply to mains plug or remove the mains plug from the socket Reconnect power If there is still a problem contact Ergomat A S The table moves at an angle Reset the table Please remember to remove cable tray first The table is no longer at level Check the adjustable levelling screws on table feet If the screws are OK reset the table Please remember to remove cable tray first The table makes an unusual noise Check that the table is not scraping up against other tables obstructions Listen to detect whether the sound is coming from the table lifting columns or from the control box If the sound comes from the lifting columns or the control box disconnect electricity supply Please contact Ergomat A S Do not attempt height adjustment until the table has been serviced Declaration of conformity We declare that the ErgoPerfect NS height adjustable table conforms to
2. In case of malfunction or similar see the Troubleshooting Guide in this manual Maintenance The table is in principle maintenance free If necessary all parts may be wiped with a slightly damp cloth and mild soapy water Internal parts may not be cleaned Never use cleaning products on electrical parts Never spray apply oil to the table lifting columns as this will damage the mechanism Assembly The table must be fitted to a plane and strong wall concrete brick For safety reasons we recommend the following e Regular checks that the wall bracket is correctly fixed to the wall After fitting the wall mounted table lifting columns must be reset by adjusting the table to its lowest position To reset push both buttons simultaneously The columns lower the table to its lowest position Then raise the table to make space for attaching the cable tray The table is now ready for use Make sure that the table has been reset before fitting the cable tray If subsequently the table has to be reset please note that the cable tray must be removed before resetting the table Ergonomics Once the table is installed check that it can easily be raised and lowered that there are no hindrances to stepless movement over the entire range of movement e Remember change working posture at regular intervals Try raising or lowering the table just a couple of centimetres at regular intervals Varying posture is key to minimising t
3. mm IN 4 3t 4x20 2 clips ERGOMAT LLC 4475 Industrial Pkwy Cleveland OH 44135 Tel 1 877 ERGOMAT info ergomat com www ergomat com oo 2 it 04x20 ERGOMAT www ergomat com
4. of connected products are long enough Carefully adjust the table to highest and lowest positions To reduce electricity consumption switch off at the mains e g at night Repairs Repairs should be carried out by an authorised technician None of the table parts may be repaired by the consumer For repairs Please contact Ergomat A S Warranty All products in the ErgoPerfect NS table series are guaranteed 2 years against defects in manufacture and materials that are a result of the normal use of the height adjustable table The right of return does not apply in the case of defects damage or wear and tear that is either directly or indirectly caused by incorrect assembly incorrect use or other actions that are not described in the user manual Disposal The table must be disposed of as follows Table top must be sent for incineration The metal table frame must be deposited as recyclable metal Electronic parts must be deposited as electrical scrap Technical specifications Dimensions 130 x 61 x 70 cm Weight 332 kg without table top Electrical connection 230 V 50 Hz Output consumption Max load 2 x 140 watts Electrical consumption standby 2 5 W Load Maximum lifting capacity 100 kg evenly distributed on table top and table frame Height range 20 cm Speed 50 mm per second not loaded Operation Connected to mains supply 230 V 50 Hz The table may be activated max 2 minutes continuously or max
5. NS100W User Manual Assembly Instructions ERGOMAT User manual ErgoPerfect amp NS100W height adjustable table Congratulations You are now the owner of the new ErgoPerfect amp NS100W height adjustable table This new modern electrically controlled height adjustable table is designed for use in office or industrial assembly environments The table is intended for use as a height adjustable work station The height adjustment function makes it possible to vary working posture bringing ergonomic improvements to the workplace We recommend that you read the user manual carefully before using the table Please note Prohibitions warnings and good advice on ergonomics The user manual should be kept with the table How the table works The height adjustment function works by means of an electric spindle motor The spindle is activated by a control box which is connected to a service panel The control box has an overload protection device that ensures that the up down function is cut off if the table is overloaded Instructions for use The height adjustment function can only be activated from the control panel that is fitted to the underside of the table top The panel has two buttons The table will move as long as pressure is applied to one of the buttons The table has no on off switch and can only be switched off at the mains contact Take care when adjusting table height danger of crushing
6. he risk of strain and injury Vary sitting posture from a seated position with thighs horizontal to a higher seat height with a slanted chair seat sloping thighs and open hip position e Recommendation use a chair with a sliding seat angle which encourages you to tip the chair reducing the risk of developing a slipped disc e Remember standing puts less strain on the back than sitting Ibo Prohibitions warnings and good advice Failure to comply with or observe all assembly safety and operation instructions and warnings regarding the use of this height adjustable table may result in serious physical injury e The height adjustable table is not intended for lifting people e The height adjustable table may not be installed on a slant or in an otherwise unstable position If the floor is not plane the table can be levelled using the levelling screws on the table feet Do not damage or crush the supply cable e The table is designed for maximum 2 minutes continuous activation or maximum 6 minutes activation per hour e Please note Height adjustment function presents a danger of crushing This applies in particular to the area under the table cross bar and any furniture on castors and the immediate area around the table top e g shelving window sills and neighbouring tables e The entire table top must be free standing at least 25 mm from shelving window sills other tables and obstructions e Check that cables
7. the following directives and other normally applicable documents e European Council Directives 98 37 EF e European Council Directives 89 336 EQF the EMC Directive and subsequent amendments European Council Directives 73 23 and subsequent amendments With reference to the Machinery Directive 98 37 EF we are obliged to state that The height adjustable table is regarded as machinery The height adjustable table must not be put into use unless it is fitted and installed in accordance with the instructions of this user manual Local agent contact information Tel 45 7022 1840 or email info ergomat dk Ergomat A S hopes you have a good day at work ErgoPerfect ERGOMAT Sunek r 13 15 DK 5471 S nders Denmark www ergomat com Packing list Pack A Pack B Pack C 1 wall bracket 4 concrete screws 7 5x80 1 cable tray 2 3t U profiles 4 steel set screws 8x14 2 clips 1 table top frame 2 table lifting columns 6 chipboard screws 04x20 1 control box 16 insex screws 08x25 14 chipboard screws 04x20 1 control panel 1 mains cable The table may only be fitted to a concrete or brick wall Drill 6 mm 2 7 5x80 4 Sx14 8 O8x25 14 4x20 p NM y Warning Safety distance to wall minimum 25