Home

Umirs RADON user manual

image

Contents

1. Disclaimer ee TL ULM E ciseenaltins 22 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS MODELS Product code Description Radon 50MRS 50 m operating distance built in external relay Radon 100MRS 100 m operating distance built in external relay Radon 200MRS 200 m operating distance built in external relay Radon 300MRS 300 m operating distance built in external relay The RADON is a double position microwave detector for outdoor applications The MRS model is available in four models RADON 50MRS RADON 100MRS RADON 200MRS RADON 300MRS that only difference in the maximum detection zone length from technical points They comprise a transmitter and a receiver unit which create a perimeter protection with coverage up to 300 m RADON 300 The transmitter and receiver should be mounted facing each other during operation The dimensions of the detection zone vary according to the distance between the receiver and transmitter units and according to the sensitivity settings The RADON microwave barrier is an advanced detection system utilizing microwave technology eliminating false alarms while maintaining high security standards for the detection of human intruders into the protected area The RADON is designed medium and long areas It can be easily installed on any type of pole It provides a solid barrier protection and blocks all perimeter activities The barrier rejects interferences caused by b
2. the multimeter connected to the two pole socket of the receiver with the enclosed measuring cable ATTENTION The detector only enters the signal measurement mode if the transmitter and receiver have already synchronized to each other and there is a constant signal on the receiver from the transmitter 1 Set the sensitivity trimmer to the lowest position 2 Wait until the alarm LED off If the alarm LED lit more than 30sec the transmitter and receiver position is not correct 3 Connect the attached measurement cable to the signal level measurement terminal connect it to a multimeter and set it to 20Vdc 4 Press the programming mode button for one second to enter the programming mode LED2 will flashing it indicates you entered the programming mode Set the position of the receiver to get the highest level Set the position of the transmitter to get the highest level Set the position of the receiver again to get the highest level DON sw NGA Press the programming mode button to exit the programming mode OPERATION Detector contact signals The self diagnostics of the detector has 3 signals 1 Normal alarm contact is closed 2 Alarm alarm contact is opened for at least 2 sec The detector generates an alarm if a walking or crawling on hands and knees human crosses the detection zone an impulse of 5 30 Vdc is supplied to remote control input 3 Trouble alarm contact is opened continuously A trouble message is gene
3. units approx 0 9 kg approx 1 2 kg Operating temperature 40 C 65 C Weatherproofness IP 65 Disclaimer The manufacturer distributor reserve the right to revise or remove any content in this manual at any time The manufacturer distributor do not warrant or assume any legal liability for the accuracy completeness or usefulness of this manual The content of this manual is subject to change without notice 22
4. distances of the units e Change frequency modulation e Change the polarization rotating 90 around detection zone axis in the same direction the transmitter and receiver e Change technology of detection TEST AND MAINTENANCE Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS It is recommended to perform routine inspection of the system with the following tests Walk test 1 Cross the detection area in different locations with different speed and body position crawling etc 2 Verify detection by observing alarm signal contacts Remote test 1 Apply 5 30 Vdc from control unit to the wire marked DC on the transmitter unit 2 Analarm signal should be received in the control unit for 2 seconds Detector maintenance 1 Check the functionality of the detectors with walk test and remote tests 2 Check the tightness of fastening elements Clear zone examination 1 Visually check if the detector condition is in compliance with mounting location chapter of the installation manual Cut off tree branches and bushes mow the grass considering the possible growth up to the next clear zone examination and remove unnecessary objects from the clear zone 2 In wintertime remove snowdrifts from the sector or increase the installation height of the detector Special maintenance 1 After snowstorms heavy rains hurricanes and in case if intensive vegetation growth it is recommended to perform extra maintenanc
5. e operations Remote test is recommended every day Walk test detector maintenance and clear zone examination is recommended according to detector s environment but at least once a year 20 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS TROUBLESHOOTING Trouble Bosibl rn ons tor Troubleshooting trouble When power supply is on the No power supply voltage Check power supply voltage of the receiver is not active does not receiver If it is off check the power enter standby mode Wrong voltage polarity supply circuit Detections are constantly Check power supply voltage of the Power supply voltage is generated in the alarm circuit detectors If it is below normal value below normal value the buzzer is on in every 2 sec check the power supply circuit Different signal frequencies Detections are constantly of the receiver and Set the same signal frequencies generated in the alarm circuit transmitter The detector has not been installed or used in Check the compliance of installation and accordance with the usage conditions with installation manual installation manual requirements High false alarm rate requirements Sensitivity is too high Adjust the suitable sensitivity The receiver is affected by a Carry out frequency or position neighboring transmitter adjustment as described in the manual Check power supply voltage of the Power supply voltage detectors If it is too high
6. e the chosen frequency modulation disconnect the power and after 10 seconds connect the power again without pressing the freq mod button The led will indicate the frequency modulation setting Positioning and focusing The transmitter and receiver units have to be placed on the opposite sides of a protected site The transmitter sends microwave impulses to the receiver The receiver analyzes the amplitude and temporal characteristics of the received signal and if these characteristics match the intruder model the detector generates an alarm signal For preliminary set up focus the receiver and transmitter as if a virtual direct line connects the receiver and the transmitter The detector can be adjusted to an angle of 15 degrees on any surface Make sure that the antenna s radiating surfaces of receiver and transmitter are parallel radiating surface is perpendicular to the virtual direct line 1 Check power supply circuits are properly connected Power supply should range from 7 5 to 30 Vdc 2 When power is supplied to detector units the number of buzzer sounds indicates the signal frequency at the transmitter and the number of LED flashes indicates the signal frequency at the receiver The receiver and transmitter of a barrier should be adjusted to the same signal frequency 17 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS Signal level measurement on receiver The actual signal level can be measured with
7. ess 5 MOUNTING THE DETECT OR ua ie 7 Mounting of the bracket e Reed tec eeterivestes siete ee adv edos qud 7 Mounting of the plastic pipe to the cable gland sese 8 Mo nting of the detectors uei ere nn Y gere eere nissen 9 Iristallationonipolea ius oer i re rd des d bestiis 10 Gross installation ar cati e deinde rege Pe ERE PU Aaa naa a tTa S 11 DETECTOR A jill c a een rennen 13 Transmitter Winner are RS ee IRRE o Re eed Nemea ero dte denos 14 POSITIONING AND FOCUSING eer op reser ea 16 Transmitter modulation adjustment euussesensesssnssnnsnenennnnennennnnnnnonnnnnnnnnnnnnnnnnnnnnnennsnnnnnnnn 16 OPERATION Bee P 18 Detector contact signals eeuessssesensnnesnsnnnsnenunnnnnnnnnnnnnnnunnnnnnnnnsnnnnnnnnnnnnnnsnnnnnnnnnnnnnnsennennnnnn 18 Operation check oot e eid RR e IT eee Trades 19 VERIFYING OF INTERFERENCE PRESENCE 45 ose n tr eu 19 TEST AND MAINTENANCE oer oaa nura x en epa ae X9 2k an anna inea ak su dnas hee 19 Walk TeSt menneen sande Gas E samo cae antedios cat ot A ru 20 Remote test ee nad ndi de Rx e cians cava EEEE RAR das RA YEN HUN vena RAT e seas dia Ae xA ee cues 20 Detector maintenance oce ot e ee el DIEBE Dekan 20 Clear zone examitiatiofic 2i e rt erue d einlegen 20 Special maintenaltice reete ete tee ete n e eese NEED ese tenis 20 TROUBLESHOOTING cci rer bacud ua diu e eae ay ko ssai ne s naar UNE ea S Sa TSE EE STEED Sane 21 i zeld e wget 22
8. ion the number of sounds indicates the signal frequency of the transmitter To change signal frequency to the next channel disconnect the brown wire wait 10 seconds then connect again Now the transmitter buzzer beeps one long four short one long then the new frequency modulation the number of sounds indicates the signal frequency of the transmitter Repeat the procedure until you reach the requested channel After frequency setting is finished disconnect the brown and green from power Connect the power supply to the detector again but the remote control wire DC green shouldn t be connected The transmitter buzzer beeps one long then the actual frequency modulation the number of sounds indicates the signal frequency of the transmitter and one long again The frequency setting is ready 16 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS Receiver modulation adjustment The frequency modulation change of receiver proceed as follows 1 with the power disconnected press and hold the modulation button 2 Connect the power with the modulation button held press the respective LED flashes quickly 3 Release the button the LED indicate the number of adjusted frequency modulation one flash for mode 1 two flashes for mode 2 etc To change the frequency modulation press the button once the LED flashes quickly and then indicates the next frequency modulation Choose the required frequency modulation 4 To sav
9. ion with 0 5 m axis distance 11 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS Fig 4 Overlapping installation of 2 systems to avoid dead zones Receiver Receiver Transmitter Transmitter Transmitter Fig 5 Overlapping installation of multiple RADON systems Receiver Transmitter oD Fig 6 Overlapping installation of RADON systems for perimeter protection 12 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS DETECTOR WIRING Fig 7 Receiver unit Fig 8Transmitter 13 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS Junction box terminals Sesitivity trimmer Led 1 Programming TT mode switch ne 2 m vene CD Modulation switch out out Sensitivity trimmer increase the sensitivity counterclockwise decrease the sensitivity clockwise Transmitter wiring Marking of wires No Functions of wires symbols colors Positive power Connect it to a positive voltage output of 7 5 30 Vdc power 1 brown source usually from the alarm control unit Negative power Connect it to a negative voltage output or ground of power source 2 white 8 P 8 P usually from the alarm control unit 14 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS Test input Connect it to a positive voltage output of 5 30 Vdc power source to test the operation of the system Duri
10. irds and small animals due to its powerful method of false alarm elimination Due to the 4 different signal frequencies more RADON detectors can be combined in order to provide complex perimeter protection with unlimited space or shape The RADON is designed for continuous round the clock operation and keeps its characteristics within a wide temperature range of 40 C up to 65 C Main features e RADON S0MRS detection zone range 20 50m e RADON 100MRS detection zone range 40 100m e RADON 200MRS detection zone range 80 200 m e RADON 300MRS detection zone range 120 300 m e Operating temperature 40 C to 65 C 4 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS e Power input 12 24 Vdc e Detection speed range 0 1 10 0 m s e Detect human intruders walking running or crawling on hands and knees e Immunity to small animals and birds motion in the detection zone 5 m away from the detector e Installation height 0 8 0 9 m e Quick and easy installation on pole fence or wall e Quick and easy setting possibilities e 4 adjustable operating frequencies e Anti dust and water resistant housing IP65 e Protection against Power supply failure direct sunlight precipitation rain and snow up to 40 mm hour wind up to 30 m s snow up to 0 5 m grass up to 0 3 m tamper SELECTING MOUNTING LOCATION The installation of the RADON requires that the transmitter and the receiver face each other
11. m detection zone length 50 100 200 300 m Approximate detection zone width 1 2 3 4m Approximate detection zone height 2 1 8 2 m Installation height 0 8 0 9 m Dead zone 3 4m Maximum height of grass on the ground 0 3 m Maximum depth of snow on the ground 0 5 m Fig 1 Approximate detection zone shape for Radon 50MRS 100MRS 200MRS 300MRS L 10 50 10 100 20 200 20 300 m Fig 2 Approximate clear zone shape for Radon 50 100 200 300 e No transport vehicle moving is allowed within a distance of 2 5m 3m 4 m 5 m RADON 50MRS 100MRS 200MRS 300MRS from the centerline between the two units Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS e Incase the detector is installed near railroad lines and main roads the distance should be atleast 5 m 6m 8 m 10 m RADON 50MRS 100MRS 200MRS 300MRS from the centerline between the two units e The detector units should be installed at least 30 m away from power lines with voltage of 35 500 KV If wiring is parallel to power lines it should be laid underground In this case it is strongly recommended to use ferrit rings to avoid interference MOUNTING THE DETECTOR Mounting of the bracket Bracket assembling Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS The older models were supplied with plastic bracket like above We supply the newest models with new aluminium bracket that you can to fit very
12. ng the test an alarm signal should be signed in the receiver Frequency modulation Use this wire if 3 DC green you want to use another transmitter frequency modulation With this function you can synchronize the operation of two devices Don t forget to change receiver frequency as well Receiver Unit Control panel COM POWER EOL SUPPLY Z1 75 30 Vdc BOARD Test button gt E gt A Transmitter Unit Fig 9 Connection to alarm control panel 15 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS Transmitter modulation adjustment In case the angle between the axes of neighboring detection zones is less than 60 or in case reflected microwave signals cross talk between the detectors that causes false alarms is possible In this case it is necessary to change the signal frequency of one of the detectors transmitter and receiver In second point it is possible to turn the detector units by 90 to the same direction To change the signal frequency of transmitter follow the recommendations l 2 Disconnect the power supply unit from the detector for 10 seconds Connect only the remote control wire DC green to positive power and the negative wire white to negative power and turn on the power supply Connect the brown wire to positive power The transmitter buzzer beeps one long four short one long then the actual frequency modulat
13. obviously and easily Mounting of the plastic pipe to the cable gland Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS Take care of the position of the detectors On the transmitter receiver the cable input should be at the bottom Mounting of the junction box Fix it to the pole by bands or screws Installation on pole Use metal poles with a diameter of 50 mm as the support Installation height of receiver and transmitter units should be in a way that the bottom surface of the plastic housing will be 0 8 0 9 m above the top of the surface ground and grass Fig 3 Installation of transmitter receiver on pole 10 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS Use the steel clams with the aluminium bracket for pole installation Fix the clams with the screws Connect the two half of the bracket and fix them by screws The fastening of screws should be the last step after focusing the transmitter and receiver in the optimal position Cross installation In order to avoid dead zones under aerials and to increase the protected area it is possible to install multiple RADON systems with overlapping Overlap configurations are performed with the units located at the angles of protected area The minimum overlap for effective protection must be at least 4 5 m in normal cross installation and 8 10 m in parallel cross installat
14. or unstable impulse level is too high or check the power supply circuit Check power supply voltage is PAM The detector does not generate the power supply by replacing it with an unstable alarm by motion operable one Sensitivity is too low Adjust suitable sensitivity The receiver is affected by a Carry out frequency or position neighboring transmitter adjustment as described in the manual 21 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS SPECIFICATIONS T RADON RADON RADON RADON 50MRS 100MRS 200MRS 300MRS Microwave frequency 10 525 0 025 GHz Maximum transmitting power 50mW Maximum length of protection zone 50m 100m 200 m 300 m Minimum length of protection zone 20m 40m 80m 120m Maximum width of protection zone vt TA caper TU Im 2m 3m 4m Maximum height of protection zone approx 1 8 2m Power supply voltage 12 24 V Power consumption Up to 30 mA at 24 Vdc Detection speed 0 1 10 m s Remote testing Built in self tester generator Alarm contact loading capacity 30 Vdc 0 1 A Warm up time after power up 30 sec Warm up time after alarm message 10 sec Flatness of ground approx 0 3 m Maximum height of grass on the ground 0 3m Maximum height of snow on the ground 0 5 m Alarm message duration approx 2 s Dimensions of units 145 x 210 x 65 mm 145 x 210 x 65 mm Weigth of
15. rated if there is interference from neighboring transmitter 18 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS voltage drops lower than 7 0 0 5 Vdc either the receiver or the transmitter unit is malfunctioning either the receiver or the transmitter unit is blocked with non radio transparent objects normal operation of the receiver unit is sabotaged by an external electromagnetic field Operation check 1 After sensitivity is adjusted check the remote control Supply power of 5 30 V to the DC Remote Control circuit of the transmitter The detector should generate an alarm 2 Running in the detector means that a 24 hour testing period should be implemented after installation preferably running for at least 3 days with all detections being registered and analyzed During running in detector s operation should be checked twice a day by test crossing the detection zone If false alarms are registered or no alarms are registered during test crossings check the sensitivity settings to eliminate defects VERIFYING OF INTERFERENCE PRESENCE To verify the absence of interference on the receiver switch off the power supply of the transmitter or use the test input of the transmitter If the receiver doesn t signal alarm in this case there are interference problem the receiver has signal from another transmitter In case of interference you can proceed as one of the following e Change the positions or the
16. rs Europe n RADON Radon 50MRS 100M RS 200MRS 300MRS Microwave barrier Installation manual This electronic device complies with EU norms EUROPEAN C C COMMUNITY about electric safety on apparatus that can generate electromagnetic interferences English version 23 04 2014 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS Dear Customer We thank you very much for choosing our item Now we would like to invite you to read carefully the following instructions before installing the product in order to use all its capacities This operation manual contains information concerning application design operation technical specifications structure of security detector RADON and installation maintenance instructions necessary for the most effective usage of its technical potential PACKAGE CONTENTS Item description Quantity Transmitter 1 Receiver 1 Plastic pipe 2 measuring cable 1 Installation assembly kit e 2 brackets 1 e Screw packet for brackets e 4 fixing wrapper Installation manual 1 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS CONTENT MODELS a e E M ocala elena 4 Main features anlegen x Fu Lage seus etse ete m UE 4 SELECTING MOUNTING LOGATION u iore Ire Y Fo dn arde cu xo Sa Y eve ern PY re nes eee dr n6 5 Avoid the following locations cccccesesssscceceeeceesesssaececeeeesssessaeeeceeeescsesesaeaeseeeesesssessasaee
17. so that the two antennas may be correctly aligned The two units must be positioned in direct line at the edge of the area The protected zone must be free from obstacles like walls fences trees ditches metal objects or other microwave detectors and systems For proper operation of RADON type of ground should be one of the following asphalt cement soil clay gravel or grass mown Avoid the following locations Avoid installation of RADON on the following type of ground thick vegetation grass not mown water sand and metal The ground must not have movable parts near the sensitive zone any grassy areas must be frequently mown there should not be any flowing water especially longitudinally ground where structural features may be changed The installation site should satisfy the following requirements see fig 1 and fig 2 e The surface of the site should be leveled with a maximum slope angle of 15 Umirs Europe Ltd RADON 50MRS 100MRS 200MRS 300MRS e No obstacles as bushes or group of trees or walls and fences metal objects within a distance of 2 5 m 3 5 m RADON 50MRS 100MRS 200MRS 300MRS from the centerline between the two units 1f maximum operating distance e Depth of snow on the ground should not be more than 0 5 m e Height of the grass on the ground should not exceed 0 3 m It is important to mow the grass regularly to avoid its movement interfering with the microwave signal Maximu