Home
p10ad-bat bufferable cctv camera power supply
Contents
1. P10AD BAT BUFFERABLE CCTV CAMERA POWER SUPPLY DISTRIBUTION UNIT WITH 10 OUTPUT BATTERY INSERTION OPTION USER S MANUAL ATTENTION Touching of mains terminal after power connection is dangerous Use of protective earthing is compulsory for safety purposes The connecting information is in the label of the power supply Use appropriate wire size on the OUT connection Normal mode OUT current together max 10 A 9A is suggested OUT voltage 12 V to 13 8 V adjustable 230V 50 60Hz O LOAD 10A WORKING MODES s i 1 Normal mode 12 V output default Per MONS 33 Connect mains to connector AC IN 230 V 50 60 Hz Sal Use for output signed LOAD connected to divider panel oan ssi Pay attention to the proper polarity 33 e NSI If the measured voltage at the cameras is dropped e g too long wire xs 53 increase the output voltage using trimmer potentiometer on the panel ii O t Measure always the voltage at the camera power input ERROR vst ocou OUT current each max 1 A with resettable PTC vl Be ay 33 a i ost I SS 2 Buffered mode MAX 1A MAX 1A A Please start the normal mode without battery to test the DC network B Switch off the buffer mode before connect the battery and switch on AC 12V 7 Ah battery can be accommodated into the box Connect mains to connector AC IN 230 V 50 60 Hz Use for out put signed LOAD connected to divider panel and connect the batt
2. ery to output BAT Pay attention to the proper pola rity Adjust the voltage on output BAT to 13 8 V by trimmer potentiometer Connect the cameras to output OUT 1 OUT 10 ATTENTION The output voltage is 13 8 V in this case Install ME 12V 1A auxiliary power supply unit into the house of camera which gives 12 VDC with max current 1 A The charging procedure of the battery is automatic I U characteristic no intervention is needed In case of power cut the battery deep discharge and break down is prevented by switching off loading at 10 5 V decreased battery voltage After returning of power the charging process starts If the charging voltage reaches 12 5 V on the battery the loading 1s reconnected This solution is working with safe and avoiding possible trouble Connection of battery red black Charging current 1A Loading current 5A OUT voltage 13 8 V The meaning of the LED signals In power default mode the battery signals do not work LED signal state LED not light Error message No power ERROR yes DC output OK DC continuous No DC output ERROR yes Battery OK BAT continuous Battery is flat ERROR yes Battery change BAT flashing ERROR yes System overheating AC DC BAT flashing ERROR yes Power on self test AC DC BAT Fan if exists ERROR no Dynamic battery test 20s Specifications Input voltage 230 VAC 10 50 60 Hz Output voltage 12 to 13 8 VDC adjustable Max loading current 10 A Class of insu
3. lation I Degree of protection IP 20 Working temperature limit range 10 C 40 C Battery 12 V 7 Ah Dimensions WxHxD mm 215 x 265 x 70 8 Built in protections against Overloading short circuit overheating deep discharge changed polarity at battery by fuse aktronix
Download Pdf Manuals
Related Search
Related Contents
ETONE Newsletter Philips 32" Flat TV 32" Full HD Black LEVIFLOW Transit-Time Ultrasonic Flowmeter - Cole HP Deskjet 2000 Printer - J210a ULTIMATE GLUE GUN LE MEILLEUR PISTOLET À COLLE LA Universal Slave Driver Guida dell`utente warning - Jacobsen (第2版)(PDF) Copyright © All rights reserved.
Failed to retrieve file