1. Both of that will show the number of the unknown caller on the display 20120713EB_HB_Baudisch SIP DoorStation EN doc 32 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 4 4 Settings VolP Network Settings The corresponding settings for the network the SIP DoorStation is integrated in must be entered here Codec Settings Selection and setting possibilities about the used codecs Extended SIP Settings Additional settings when required System System settings such as passwords time zone etc 4 4 1 Network General information Network Type Baudisch SIP DoorStation MAC address 00 50 C2 A1 66 B9 Versions 056000 v7 8 6 4 V4 6 Network settings Type of connection Manual IP Address zl IP Address IEN 68 1 202 Subnet mask 255 255 255 0 Standard gateway fi 92 168 1 1 Get DNS server IP automatically Use following IP Address Primary DNS hee 68 1 1 Secondary DNS fi 92 168 1 1 Layer 3 QoS fo Diff Serv or precedence value Layer 2 QoS 802 1Q VLAN Tag fo 802 1P Priority Value po Save Reset Network settings Connection type The network settings can be either manually entered when Manual IP Address is chosen or automatically set via a DHCP Dynamic Host Configuration Protocol server 20120713EB_HB_Baudisch SIP DoorStation EN doc 33 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch IP a
2. chain call 4 3 2 Direct Call Keys It is possible to connect up to 15 external direct call buttons to the 4 inputs entries 1 2 4 and matrix d m Baudisch SIP rect call keys 8 I If it is necessary to connect more than 4 buttons it is needed to use an bit encoder diode DoorStation Direct call keys Name Number DTMF Code Incoming Outgoing Relay Group ID fe beem pA IS i el accep ed Announcement lo E frone 102 LZ ZZ 2 Reject Announcement of I o None 103 LZ ZZ z Announcement Of z 0f zl None de Fe EEE it Arncuncemens OF aa Ov E None STI FR Eer IECH mm Reject Announcement Off Off z nne 107 aAA HA Rer Announcement Off e oF Mone deel LZ Announcement ot I OF E None Le SI SI SS Reject x Announcement Off x for E None og LZ freies Announcement Of oF None ee Cc Hal LZ 2 Re E announcement on eI OF Le None E 13 LZ SS Reject z Announcement Off x for Gi None Ma LZ ZZ A Ri Announcement Of of None a aaraa Reject z Announcement Off Il Off x None aia tia EHEN ER TER TER EHER TEN TER IE 4 4 Save Reset I Please refer to chapter 4 3 Phone Book for the descriptions 20120713EB_HB_Baudisch SIP DoorStation EN doc 31 82 In case of a straight through connection of buttons to the inputs the buttons call the phone book Eb 13 07 2012 B
3. Pushing the arrow keys in stand by mode shows up the phone book After the entered time the device falls back to the stand by mode when there is no further button operation Length of ID announcement Here the length of the recorded announcement must be set LCD Backlight Off permanently switched off s On permanently switched on e Auto Active in case of any operation or an incoming call Extension port Function The extension port serves the connection of external add on modules and intra company service purposes An external add on module could for example be a switch component which makes it possible to connect up to 115 ring buttons at the intercom DHCP Retry Timeout In some network the distribution of IP addresses by DHCP is very lazy To avoid a time out please enter the time until the device must wait 20120713EB_HB_Baudisch SIP DoorStation EN doc 42 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Baudisch 4 5 3 Call Options Call Opt Common Call Opt Stat ata Max Call duration 0 endless 1min p ka Timeout connection attempt 0 notimeout 1sec 3 fo Redial attempts None E Delay between redial attempts t 1sec o 2 Wait for acknowledge DTMF char for ACK pel Call by Phonebook No Call to Switchboard No zl Direct Call Keys No E Call Chain Option Call Chain Cycles Ko Save Reset Common Maximum call duration Call time limit The call
4. z n Gr 2 Baudisch x e e SS e rrt I PT _ o _ r1trr RA aS BK IN DO Or Baudisch SIP DoorStation IP54 Standard Video Manual History Version Date Name Change 1 0 09 07 2012 T Eberhardt Translation Approval latest version Date Name Division Initial Signature checked 13 07 2012 T Eberhardt DEV Eb checked PF checked VT checked User checked FE 20120713EB_HB_Baudisch SIP DoorStation EN doc Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch Table of Content Table of Content 2 1 General Information 5 El symbols 5 1 2 Software History 5 1 3 Hardware Ee LCE 7 1 4 Fundamentals of VoIP and op 8 1 41 SIP UNGUA B23 rasen anna aaa a ala na aa aaa aan i 8 1 4 2 Advantages of the SIP Protocol nn 8 1 4 3 Transmission and Connection Types of Calls nen 8 2 Product DESCrIptioni riali 9 2 1 General Information anne 9 2 2 Settings VolP eu hehe 11 E Dee RRE EE 12 3 Starting Te EE 17 I eut ee 17 3 2 Mechanical COMMISSIONING i 23 3 2 1 Opening the SIP DoorStation nenene anana 23 3 2 2 Fastening of the SIP DoorStation i 23 3 2 3 Cable Connection cece eececeseeeseeeeeseeseeueeaueeeeeesese
5. Baudisch Version 1 8 As of 13 07 2012 4 4 3 SIP Settings i n Baudisch SIP DoorStation SIP settings SIP registration Ve yes gs SIP Server Ir E IP or URI SIP Settings SIP Server Port 5060 Standard 5060 S se SIP Domain SIP Server as Outbound Proxy Ce No O Yes Use DNS SRY ZS Mo Cres SIP User ID SIP authentication ID SIP authentication PIN leese Username Optional e g John Public _Sove Reset SIP registration Indicates if the intercom should be registered by the SIP server If this option is not activated only direct connections IP to IP are possible A connection via call numbers is not possible SIP Server and SIP Server Port The IP address the URL of the SIP provider or a SIP telephone system is entered here The port number specifies to which port the server listens SIP Domain It serves the determination of contacts and is used for the connection buildup together with the number in the SIP protocol A connection via a call number can not occur without it The IP address of the SIP server can be entered here instead of a name SIP Server as Outbound Proxy Use the SIP server as proxy for outgoing calls However it must also be supported by the SIP server This way telephone calls can be made through a NAT firewall Use DNS SRV To reach a contact within the SIP domain use the DNS server entry SIP User ID It is the ID within a SIP domain which is us
6. Password Choose an option and login with the factory default password 1234 20120713EB_HB_Baudisch SIP DoorStation EN doc 29 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 E Baudisch 4 3 Phone Book 4 3 1 Phone Book Browse M ode i E Baudisch SIP DoorStation Phone book for browse mode Phone book for browse mode Name Number DTMF Code Incoming Outgoing Relay Group ID 1 ee pena Il zs zl l n ed Armouncement Of fon lge 2 Name2 fisz t68 1 2 p AR le la leet Announcement Of ll op EJ None 3 Names 654321 paran ale A ser Announcement Off off None 4 Named 123456 Elf Es RIA ST Announcement Off Si None SOOO a Ri fee E Announcement of Or lge i SEE rr on Or en IT a Ri free ed Announcement of Zar None LS 14 FSF RIF RIF RI Riso Announcement of z or None S FEaI SI SF RI Rie Announcement off or none ae Here you can enter all subscribers which should be shown on the display in browse mode At the bottom of the site there is a button to save the entries Name A name for the call destination must be entered here Both fields below are reserved for expansions and remain blank Number Here is the entry for the phone number or the IP address IP entry with dots entered DTMF code In order to trigger the relay with the door opening function an additional code can be entered via a keypad at the r
7. SIP Remote Control e Destination address Destination of the data package The IP address of the SIP DoorStation which is remote controlled or should be updated must be entered here e Input port 8112 UDP port for incoming data The setting must match the port for the status messages in the configuration of the SIP DoorStation e Output port 8113 e UDP port for outgoing data The setting must match the port for the remote control in the configuration of the SIP DoorStation I The specified ports are not to be blocked by a firewall on your computer otherwise the SIP remote control cannot establish a connection with the SIP DoorStation 20120713EB_HB_Baudisch SIP DoorStation EN doc 64 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Baudisch e Unlock Enter the unlock code Update case sensitive The basic functions include the remote control of the relay and the camera IOs as well as the possibility to restart the SIP DoorStation By entering Update the boot loader function is activated Code DTMF central call This setting must match the code setting for the central call at the intercom 6 Push the button Open I A connection is established when the data is shown in the following form in the window Received The screen is similar to the example Empfangen Absender IP 192 168 1 200 Ga OxD5 0x25 OxDA System idle SFO 1 8 2
8. fe x Emulation Parity None sl TTY X Terminal Setup 2 Telnet terminal ID TELETYPE 33 Stop bits fi D Backscroll buffer lines 500 a Flow control DESS Di I Play sound when connecting or disconnecting Input Translation ASCII Setup Restore Defaults The flow control is switched off A simple TTY Terminal is sufficient 20120713EB_HB_Baudisch SIP DoorStation EN doc 49 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch m ASCII Sending IV Send line ends with line feeds IV Echo typed characters locally Line delay fo milliseconds Character delay fo milliseconds m ASCII Receiving TT Append line feeds to incoming line ends TT Force incoming data to 7 bit ASCII IV Wrap lines that exceed terminal width Carcel It is recommended to activate a local echo to track the entered commands iojx Datei Besrbelten Ansicht Aneufegg bertragung Dis 13 aal sl Baudisch SIP V1 6 ready 07 DSP Ready Settings reloaded 4 gt Verbunden 00 01 28 K Kess FF rest If the settings are right and the SIP DoorStation powers up you can see a message in the terminal Resetting 1 Turn of the power supply of the SIP DoorStation and connect the serial interface ofthe PC to the SIP DoorStation 2 Launch the terminal application The SIP DoorStation must also be connected to the LAN Push the two buttons
9. of phone book the symbols A Z a z and are now allowed e DSP_COM reset time changed to 40 seconds und tones changed Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 27 10 2009 V5 1 042001 V5 5 V2 6 e Calculation of the values from SIP Control audio dialogue corrected e Chain call changed to group ID e Remote control authentication moved to hardware settings e Output of version string corrected e DTMF receive via RFC corrected 2 symbols transmitted 1 received e Data format of phone book has changed Updating the firmware from versions older than 5 0 will lead into loss of phone book entries 18 06 2009 V4 1 042001 V5 2 V1 2 e Optimization web interface 1 3 Hardware Versions 27 11 2009 Further devices customization of population 08 04 2009 Marking and layout optimized 27 02 2009 1 3 e Extended level adjustment DTMF acknowledgement e Screw type terminal added keys pluggable e Change of population 10 11 2008 New DSP 25 10 2007 1 0 e TTL interface added e Ethernet switch ribbon cable connector added e Serial and alternative parallel decoder added e New Display 20120713EB_HB_Baudisch SIP DoorStation EN doc 7 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 1 4 Fundamentals of VolP and SIP The transmission of voice and images over the Ethernet and by IP is increasingly replacing analog and I
10. which parameters are to be changed must be entered here e Input port 8112 UDP port for incoming data The setting must match the port for the status messages in the configuration of the SIP door module e Output port 8113 UDP port for outgoing data The setting must match the port for the remote control in the configuration of the SIP DoorStation I The specified ports are not to be blocked by a firewall on your computer otherwise the SIP remote control cannot establish a connection with the SIP DoorStation e Unlock Enter the unlock code Setup case sensitive The basic functions include the remote control of the relay and the camera IOs as well as the possibility to restart the SIP DoorStation By entering Setup the boot loader function is activated Code DTMF central call This setting must match the code setting for the central call at the intercom 20120713EB_HB_Baudisch SIP DoorStation EN doc 71 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 6 Click on the button Open e I A connection is established when the data is shown in the following form in the window Received The screen is similar to the example r Empfangen Absender IP___ Status Parameter ecc seg 192 168 1 200 0x0A System idle v5f0 v1 8 V2 6 i OxDS 0x25 7 By clicking the button Parameter HW ID the following window opens up Setup HW ID g E
11. 1 8 As of 13 07 2012 Ei Baudisch 3 Starting up 3 1 Preconfiguration e I After the installation to activate the SIP DoorStation an IP address in the address range of the network has to be assigned to it This setup can be carried out with a PC laptop which is directly connected to the door module along with an external 24V power supply see chapter 4 4 1 Network Another possibility without external power would be to connect the SIP DoorStation to a PC laptop via a PoE switch e I To be able to connect to the SIP DoorStation it is necessary that the PC laptop temporarily is setup for the IP address range of the door module The address range is defined from 192 168 1 1 to 192 168 1 254 with the delivery The door module has the address 192 168 1 200 To configure the SIP DoorStation follow the upcoming instructions 1 Temporarily change the IP address and the address range of the PC laptop examples shown on Windows XP a settings network connections LAN connections 4 Local Area Connection Properties a General Authentication Advanced Connect using E Intel R PRO 100 Network Connectio This connection uses the following items vi el Client for Microsoft Networks a File and Printer Sharing for Microsoft Networks d E QoS Packet Scheduler Internet Protocol TCP IP Description Transmission Control Protocol Internet Protocol The default wide area network protocol that p
12. 8 modules Material Aluminum diecast Color Silver metallic SM Basically the Stele can be delivered in all colors of the company Siedle SM is recommended as this fits best for aluminum metallic design of the built in modules 14 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch Installation kit sabotage contact Installation kit with sabotage contact Art Nr 33 0215 Features e Switch is operates by housing To temper proof your installation connect it to do a direct call or to switch off door release buzzer e Can also be connected to the LAN SecureAdapter 33 0216 to cut LAN and outdoor opener lines in case of sabotage I Connect the sabotage contact to the LAN SecureAdapter to disconnect network an power Baudisch SIP VideoClient Software tool for automatic video pop up at an incoming Art Nr 36 0204 call browser independent SIP DoorStation video only Features e Operate the electrical release buzzer or do a call by click e Function to save pictures in JPG by click 20120713EB_HB_Baudisch SIP DoorStation EN doc 15 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch LAN Secure Adapter Disconnects power supply and network in case of Art Nr 33 0216 sabotage Description It is risky to install IP devices outdoors because of anybody can open the housing of a device and connect to the internal LA
13. Bit 4 no function Bit 5 no function Bit 6 no function Bit 7 no function This function is used to end the dialing process or disconnects a call when the door opening relay was activated via the UDP remote control Each relay must be configured with the function door opener Otherwise the function is only executed when bit 2 or bit 3 is set 6 3 1 5 Activation of the DTMF Relay Selection Parameter EnableDTMFDoorSelect Address 0x0605 1541d If this parameter is set to a value other than 0 then the relay to be used can be selected with the code sequence 99n giving n one of the following values 0 Both relays always with a new connection or after DTMF timeout 1 only switch relay 1 2 only switch relay 2 The actual door opening code must be sent immediately after the selection sequence otherwise the selection value is reset due to the timeout I Also when the function is activated the door code can still be entered alone without preselection 99n 20120713EB_HB_Baudisch SIP DoorStation EN doc 69 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 6 3 2 Read or Write the Configuration Parameters These parameters can be changed with the software SIP Remote Control from Baudisch Electronic You receive the software on request E mail update baudisch de Read or write parameters with SIP Remote Control Before you can start SIP Remote Control
14. Control On e SIP NOTIFY URL to Snom XML file e g 192 168 1 x snom cgi 192 168 1 10 snom cgi _Save Reset Code for remote authentication To be able to remote control the code entered here must correspond with the entered code in the protocol IP Address Specifies the destination address to which the status messages are to be sent It is the broadcast address by default This way the messages are sent to all contacts in the sub net It only makes sense when several contacts in a network should receive the messages Otherwise only a direct destination address should be entered here Status Port Transmit Identification number of the application Thereby special basic conditions firewall etc can be considered Remote Port Receive Identification number of the application Thereby special basic conditions firewall etc can be considered Status Status messages are sent when this option is activated In case of deactivation no confirmations are sent not even by using the remote control function The status messages and the applied protocol are described in more detail in chapter 6 4 Status Messages Remote Control The relays of the SIP DoorStation can be operated by remote control over the network when this function is activated By the SIP DoorStation both camera IOs can additionally be controlled The remote control operates indeed by activated remote control however without activated status messag
15. DoorStation 4 7 1 Version 1 8 As of 13 07 2012 Ei Baudisch The corresponding update files are available from Baudisch or the files can be generated on your own according to the instructions manual for the ring tone or the announcement Firmware The software of the Baudisch SIP DoorStation can be updated by updating the firmware If there is a DSP firmware older than V4 2 installed to the SIP DoorStation write down the phone book entries because they will get lost if you are updating Find out your DSP firmware version in web interface menu Settings VoIP a network The current version is shown in brackets I Ei Baudisch SIP DoorStation General information Network s Type Baudisch SIP DoorStation Codec Settings WAC address 00 50 C2 4 1 66 88 SIP Sett Versions 056000 V7 8 v6 4 V4 6 SIP Settings The update is available from Baudisch on request Send us an e mail with the product names and serial numbers We need this information in order to send you the applicable firmware In case you do not have the serial numbers indicate the date of purchase E mail update baudisch de To keep the functions of the SIP DoorStation warranted an update of the AVR firmware should follow an update of the firmware see chapter 4 7 1 Firmware To perform an update of the firmware 1 Start the configuration menu see chapter 4 2 Start of the Configuration Menu 2 Choose updates enter password and login 3 Cho
16. FF Status Specifies the current status or type of the data message The status consists of a 2 byte Hex string Parameter bytes The parameter bytes complement the status bytes They contain detailed information about the status bytes for example a phone number status refinement etc The parameter always consists of 24 characters ASCII no functional characters Unused spaces are filled with blanks Proof total The proof total is used to check if the data package contains correct status data A transmission backup is done over the Ethernet transmission layer CRC32 The proof total consists of a 2 byte HEX string and is made up of all data bytes as Addition Modulo 256 6 4 2 Messages Status Parameter bytes Description bytes 0x0A lt blank gt or lt XY gt Idie mode IDLE XY Firmware version ATmega 2 digits HEX 0x01 Number of the caller Incoming call 0x05 Number of the remote Connection status station 0x06 lt blank gt Status to dial 0x07 Number of the remote Dialing status station 0x14 Send identification A maximum of 24 characters of the optional user name SIP settings is transmitted 0x4C Byte0 0x31 SIP server log on successful Byte0 0x32 SIP server log on failed Ox1E see remote protocol Response to remote message 20120713EB_HB_Baudisch SIP DoorStation EN doc 73 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 6 5 Remote Control The
17. Save Reset Precedence control Switching threshold for Remote station speaking Sensitivity of the switching to remote station speaking Be aware that the volume while speaking doesn t stay constant Switching time for Remote station speaking Delay of the return switching when below the switching threshold Remote station speaking Microphone and Speaker level Microphone level and speaker level when the switching is active Then the microphone level should be lower than with remote station listening and the speaker level should be higher Remote station listening microphone and Speaker level Microphone level and speaker level when the switching is not active Then the speaker level should be lower than with remote station speaking and the microphone level should be higher 20120713EB_HB_Baudisch SIP DoorStation EN doc 40 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 E Baudisch Signaling Level of Ring tone incoming call The volume of the ring tone being played back The dial and busy tones while dialing are played back with half of the preset value Level to signal tones to local speaker The volume of the signal tones which is heard by the person at the intercom local Included are the button confirmation tones the switch on tune and action confirmation for example call ended Level of signal tones to remote station The setting decides the volume o
18. arrow up and arrow down permanently simultaneous Turn on the Power supply PoE Endspan or connection terminal Keep pushing the two buttons and wait for about 10 seconds Push the call button for a short time If everything was done right a sound plays 6 After further 10 seconds keep the buttons pushed there will sound another sound and the device is in safe mode The terminal output will change and the buttons can get released d SIP Sprechstelle HyperTerminal loj x Datei Bearbeiten Ansicht Anrufen bertragung ole ls le Save Mode tfactory Factory settings restored H gt Verbunden 00 07 12 jiszooe n 1 RF GROSS 5 In the terminal output you can see Save Mode 7 Enter the command factory no quotation marks and push the enter key e Now the factory settings will get loaded The is the terminal output Factory settings restored 20120713EB_HB_Baudisch SIP DoorStation EN doc 50 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 4 8 2 Hardware Reset higher than V1 0 1 Turn off the power supply 2 Keep the button Arrow up pushed 3 Turn on the power supply PoE Endpan or connection terminal 4 Wait for approx 5 8 seconds and push the call button for a short time You can hear a sound Keep the arrow up button pushed until you hear another sound There is a O shown in the display Do not set the jumper to po
19. is also automatically possible during a call or during dialing Of course a special code at the snom 820 can also trigger the switch to open the door in the SIP DoorStation during a call I Detailed information and application notes are provided upon request 20120713EB_HB_Baudisch SIP DoorStation EN doc 77 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 6 8 Guide for Audio Settings To facilitate the setup audio settings can be changed during an ongoing call This is done using a special process the DTMF code The audio settings changed this way are not saved and after the hang up reset to the original values Reasonable values can be set permanently over the configuration menu which is described in chapter 4 5 1 Audio DTMF Code All DTMF commands for special functions are five digits and entered using the buttons on one of the phones connected to the intercom They start with a star followed by a command digit two digits for the parameter and end with the hash button 6 9 DTMF Code Example Command setup lt star gt lt command gt lt parameter gt lt hash gt Examplet II Example2 8 I For the guide to work by the change of the audio characteristics it has to be activated with 999 To be able to test the settings without delay the DTMF muting is deactivated Possible DTMF commands po ag Command Reset pre selection of door opener relay requires
20. module the Baudisch SIP DoorStation supports EasyLan if desired The protocol description of the EasyLan interface is not published However it can be handed out by signing a confidentiality agreement NDA 6 2 2 Using an EasyLan Connection This way the Baudisch SIP DoorStation can be controlled via field bus modules from a distance of up to 1 24miles It can process a request to make or end a call open the door or give a sound output SS R EasyLan Bus SE cable length up to 1 24 miles Baudisch EasyLan 3 zen Feldbusmodul See cat 6 2 3 Baudisch EasyLan Field Bus M odule and Functions 6 2 3 1 Controlling per PC or Embedded PC via an EasyLan PC Interface uep iP RS232 Art Nr 36 0176 Art Nr 36 0194 Art Nr 36 0101 EasyLan PC Interface 20120713EB_HB_Baudisch SIP DoorStation EN doc 66 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 6 2 3 2 The Connection to the ASB_32InSPS_40utRelais Art Nr 36 0133 NEDAmgAnge 17 32 Egon 3A T PY ee e E E The ASB is used to connect the call buttons to the SIP DoorStation It is possible to use up to 4 ASB with addresses 0x58 0x59 0x5A and 0x5B The message CO is analyzed by the DoorStation Other messages will be ignored Device address input pesi ae 29 32 Phone book entry 1 4 Product details e This EasyLan switch component can detect 32
21. no service mode Pre selection of door opener relay 1 requires no service mode Remote station speaking speaker level Volume of the signals in the local speaker Remote station listening microphone level Remote station speaking microphone level Switching threshold for remote station speaking Switching time for remote station speaking value 100ms Pre selection of door opener relay 2 requires no service mode Volume of the signals to the remote station N _ 20120713EB_HB_Baudisch SIP DoorStation EN doc 78 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 6 10 Create Ring Tones and Announcement M essages The ring tone and the announcement message e g a message about the location of the intercom which the called person hears can be created and loaded into the intercom However the audio template must be in the appropriate form raw format to G711 u Law and then converted to the loadable flash binary format For this purpose the company Baudisch Electronic GmbH provides an appropriate tool upon request The tool inserts a 2 second silence at the beginning of the audio stream which is required as a forerun In addition the audio stream is set in a predetermined frequency range and converted into the right format You need the following files 1 mkSipSnd exe conversion tool 2 Audio stream in wav format for announcement and ring tone The audio
22. the following configurations must be made on the web interface of the SIP DoorStation 1 Start the configuration menu see chapter 4 2 Start of the Configuration Menu e Choose hardware settings enter password and login standard password 1234 2 Choose status remote control and select the following settings IP address Here the IP address of the PC should be entered over which the parameters are changed s Status port send 8112 recommended Remote control port receive 8113 recommended Status on S Remote control on Save Start SIP Remote Control Open the file to be executed SIPControl exe which you received as an attachment in our e mail The following screen is shown 20120713EB_HB_Baudisch SIP DoorStation EN doc 70 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 al Baudisch TE Baudisch SIP Remote Control B m mi Einstellungen Senden Zieladresse 192 168 1 200 192 168 1 200 168 Releais IOs Remote Senden Eingangsport e112 Relais de 2 fo fo fo DI F CMD senden Ausgangsport 8113 Open I so 4 del fo tt fo bes fo Y fo e Unlock Ausschalten v nd Code DTMF Zentralruf 1 vl vl v4 Sendedaten Empfangen Absender IP Program beenden 5 Make the following settings in the SIP Remote Control Destination address Destination of the data package The IP address of the SIP door module
23. tot he phone book To select an entry there are two buttons on the left hand side to browse and one button on the right to call the selected entry Features Version Standard Video Suitable for outdoor applications protection class IP54 Vandalism protected This robust station characterized a faster call setup and a loud rendition of a very good quality Protection against poking the speaker The communication is realized via VoiceOverIP VoIP and the connected Ethernet LAN either directly to a SIP compatible phone or a SIP compatible telephone system or via internet and a SIP provider Priority of control center voice allows communication if the SIP DoorStation is installed a noisy environment Simple configuration via integrated web server available in several languages German English French Italian Switching contacts for electrical door release buzzer via DTMF or UDP command Switching contacts for electrical lightning or central external bell Emergency logic Features as redial acknowledge of received call by control center via DTMF and call forwarding to alternative subscribers The configuration can be done easily via web browser The power supply can be realized via LAN PoE Class 0 or a directly connected mains adaptor It is possible to connect external direct call buttons Further it is possible to use a device to connect up to 115 buttons each calling a specific phone book entry Precious brushed alumin
24. 12 Ei Baudisch 6 Extras 6 1 AVR Firmware Update e I An update of the AVR firmware is only recommended when you have previously installed an update for the SIP DoorStation see chapter 4 7 1 Firmware A program SIP Remote Control was developed which enables an update of the firmware over the network without opening the device Why and when should the AVR firmware be updated To keep the functions of the SIP DoorStation warranted an update of the AVR firmware should be made after an update of the firmware is performed How do I get the latest firmware and SIP Remote Control You receive the SIP Remote Control and the AVR firmware together with the e mail in which the firmware for the SIP DoorStation is provided on your request To perform an update of the AVR firmware via the boot loader function in SIP Remote Control Before you can start the SIP Remote Control the following configurations must be made in the web interface of the SIP DoorStation 1 Start the configuration menu see chapter 4 2 Start of the Configuration Menu Select hardware settings enter password and login standard password 1234 2 Select status remote control and enter the following settings IP address The IP address of the PC over which the firmware update is made should be entered here Otherwise there is too much data communication in the network Status port send 8112 recommended Remote control port receive 8113 rec
25. 45 SIP Sprechstelle ECO Standard crossover cable RJ45 power supply or Establish connection from PC laptop to door module via PoE switch Connect the SIP door module directly to the PC laptop with a network cable and to an external power supply 24VDC 1A fused Start the configuration menu see chapter 4 2 Start of the Configuration Menu 192 168 1 200 Access the starting page in the web browser using the factory preset IP address Choose Settings VoIP and login using preset password 1234 see chapter 4 4 1 Network n Now you are in the sub menu network and you can carry out your network settings address Is the new IP address saved then the configurations menu can only be accessed with this 20120713EB_HB_Baudisch SIP DoorStation EN doc 22 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 3 2 Mechanical Commissioning 3 2 1 Opening the SIP DoorStation To mount the SIP DoorStation at a wall and to insert the wires the device must be open The housing consists of two parts The rear part is to fix at the wall the front part includes the electronic To open the housing remove the screws at the bottom side 3 2 2 Fastening of the SIP DoorStation Use 4 screws with a diameter of up to 4mm to mount the rear part of the housing at the wall To avoid the intrusion of water use the delivered clogging plates I Please see chapter 5 2 Technical Drawing
26. 6 7 By pressing the button Bootloader the following window opens up Bootloader ei E Firmwaredatei Firmware schreiben EEPROM Datei EEPROM schreiben Status Wait for Selection Progress Info Info T Detail Schlie en 8 Enter the path of the file xxx hex in the firmware file which you have received as an e mail attachment 9 Make a check at Firmware schreiben 10 By pressing Start the firmware is installed The process may take longer and is complete when Operation successful is shown in the status field Deactivate state and remote control in web interface I Reset the status and remote control in the web interface to off You have successfully completed the update of the AVR firmware 20120713EB_HB_Baudisch SIP DoorStation EN doc 65 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch Bl u cei EasyLan Connection 6 2 1 General Information The EasyLan Bus was developed by Baudisch Electronic GmbH to link together electronic components devices and systems in a simple manner The data bus enables secure communication between individual devices A bus segment can consist of up to 1 24miles shielded cable 2x0 6mm and can differentiate up to 64 participating devices The Baudisch SIP DoorStation MAXI has the necessary connections and can be integrated into an EasyLan system With a additional
27. 8 0 09 20120713EB_HB_Baudisch SIP DoorStation EN doc 19 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch i click on OK 4 Local Area Connection Properties General Authentication Advanced Connect using st Intel R PRO 100 Network Connectio This connection uses the following items v S Client for Microsoft Networks Wi a File and Printer Sharing for Microsoft Networks x 005 Packet Scheduler Internet Protocol TCP IP Description Transmission Control Protocol Intemet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Lal Show icon in notification area when connected Notify me when this connection has limited or no connectivity j click on OK I Now the installed PC laptop is ready to be connected to the SIP DoorStation k when the fields Obtain an IP address automatically and Use the following DNS server addresses are activated then click on Use the following IP address Internet Protocol TCP IP Properties You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address Obtain DNS server address automatically Use the following DNS server add
28. B_HB_Baudisch SIP DoorStation EN doc 27 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 E Baudisch Wiring diagram of a typical installation SIP Doorstation relais door 24VDC opener supply door opener 20120713EB_HB_Baudisch SIP DoorStation EN doc outer saved sabotage contact inner zone LAN secure o o 4 r adapter 24VDC 230VAC 24VDC Sabot bell power unit Sabo2 Power Si transformer 24V Du our 24V 31 0556 31 0113 24V_OUT 36 0143 i A2VAC 230VAC 28 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 4 Use and Configuration 4 1 4 2 Starting Requirements e Connection of the Baudisch SIP DoorStation with an Ethernet 10 100 LAN e The supply of current can take place over the Ethernet via PoE Power over Ethernet or with a suitable power supply Start of the Configuration M enu Access the starting page of the web interface by entering the factory preset IP address 192 168 1 200 in the web browser The web interface is tested with the following internet browsers Mozilla Firefox 13 Microsoft Internet Explorer 9 Apple Safari 5 2 cA Baudisch SIP DoorStation ii 192 168 1 200 e A 8 coo PR A Baudisch SIP DoorStation Phone book Settings VolP Cc Settings Hardware Updates
29. EPROM Zellen lesen schreiben Adresse 16 bit 0x0000 Datum 8 bit 0x00 Schreiben Datum gelesen BE Lesen Hardware ID HIGH 8 bit1 Ger tekennung 0x04 esen LOW 8 bit Platinenversion gaw Misc 24 bit 0x000000 r Status ID read successful Werkseinstellungen Gleiche Funktion wie Load Store Fa Jumper Laden Schlie en 8 In the Address field is the address of the parameter entered which is to be changed or read 9 In the Date field is the new value entered when you want to write 10 By pressing write or read is the corresponding action executed 20120713EB_HB_Baudisch SIP DoorStation EN doc 72 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 6 4 Status Messages Status changes and current statuses can be sent as status messages via an UDP data package from the SIP DoorStation Status messages must be activated and a recipient IP address must be entered in the configuration menu under Status Remote 6 4 1 Protocol A UDP data package is structured as follows lt Sequence number gt lt Status gt lt Parameter bytes gt lt Proof total gt Sequence number Number of the current data batch Is always increased by 1 until 255 is reached and then restarts at 0 This allows the recognition of multiple reception of a data batch The sequence number consists of a 2 byte HEX string example 01
30. Ei Baudisch NAT Traversal Here is defined how the door module identifies its public IP address when the door module is located behind a NAT firewall or alternatively a router This can be done either by a permanent IP address for example a dedicated line with the option use NAT IP or by a dynamic assignment via a STUN server This option can be deactivated when exclusively a local network is used NAT IP Describes the IP address of the door module from the view of the internet WAN address This should automatically occur via a STUN server by a dynamic assignment STUN Server and STUN Server Port IP or URL of the server over which the current public IP address of the door module should be identified and its port number 4 4 5 System i Baudisch SIP DoorStation System settings Administrator Passwort Password to enter this web interface Syslog Server IP fi 92 168 1 5 aten SNTP Server ntp1 ptb de IP or URI e g time windows com Help Timezone GMT 01 00 Amsterdam Berlin Berne Rome Stockholm r Automatically Adjust Clock for Daylight Saving Changes C vo ves Save Reset Administrator password Access password for the configuration of the door module via the web interface The factory preset standard password is 1234 Syslog server IP The IP address which is specified here can be used to forward system information to a Syslog server When the IP is set to 0 0 0 0 the mode is d
31. IP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 5 Product Details 5 1 Technical Date Connectors and interfaces Ethernet over RJ45 Ethernet with PoE a without external supply 10 100 Mbit s Ethernet with PoE a with external supply Screw type terminal Grounding PE External supply Masse 24 20 36VDC 1A fused Relay closing contact potential free contacts max load 24V 1A for electric door buzzer Relay closing contact potential free contacts max load 24V 1A for electrical lightning relays 4 inputs for external potential free buttons for direct calls binary coded to call up to 15 subscribers directly Ribbon cable connector TTL Service Interface SCI Physical characteristics Dimensions Baudisch SIP DoorStation Standard 99 0 mm x 198 5 mm x 38 3 mm LxBxH Baudisch SIP DoorStation Video 99 0 mm x 298 0 mm x 38 3 mm LxBxH Operating voltage 48V supply via PoE Power over Ethernet SIP DoorStation Standard Video a Class 0 Endspan Midspan 24V DC 20 36V DC 1A fused by external supply Power input Baudisch SIP DoorStation Standard ca 4 VA Baudisch SIP DoorStation Video ca 9 VA Weight e Baudisch SIP DoorStation Standard 895g e Baudisch SIP DoorStation Video 1 460 g Protection class IP54 for outdoor installation splash proofed Option IP65 powerful water jet protected Material color Housing consists of satin aluminum light anodized Environmental conditions Working t
32. IP Terminal MODULAR KSF 33 1396 Baudisch Dummy module MODULAR KSF 33 0215 Installation kit sabotage contact 33 0216 Baudisch LAN SecureAdapter 36 0204 Baudisch SIP VideoClient o Bi lo o o Vv Q o ba E E E 0 Le o I The optional accessories are not included in the delivery contents and must be ordered separately 20120713EB_HB_Baudisch SIP DoorStation EN doc 13 82 Eb 13 07 2012 Baudisch SIP DoorStation Optional Accessories IP Terminal MODULAR KSF Art Nr 33 1397 20120713EB_HB_Baudisch SIP DoorStation EN doc Version 1 8 As of 13 07 2012 Baudisch Description Product information Siedle stele type KSF 616 4 with floor flange includes mounting material and front panel Prepared for devices MODUAR KSF Without equipment without tamper switch Features The stele is prepared to receive the devices MODULAR KSF These include two small millings in upper cover in non visible range The stele is also purchased directly in the electrical wholesale In this case cover is send to us to make the millings Model 33 1397A e Hidden cable management within the column with outlet downwards or to the lower rear side of the tube Dimensions e Height incl socket Standard 1644mm and 1344mm e Stele 130 x 150mm e Socket 211 x 230mm The Stele is available in different heights and numbers of modules e Other heights with delivery time in 100mm increments e 1
33. N To avoid this the LAN Secure Adapter is connected to the network cable in the building In case of a detected sabotage the devices switches off the power and the network connection Features e DIN rail mounting e Disconnects network and power supply in case of detected sabotage e 24V DC power supply needed e Reset button e Two pole switching contact 24V and GND get disconnect in case of sabotage e The switched 24V can be useful to enable the electrical release buzzer So it is prevented to open the door in case of sabotage e It is useful to use the switched GND to report sabotage to a facility management system Function Two current loops are monitored separately If there is a malfunction detected on one loop it is called state of sabotage 1 Mode Monitoring of the sabotage contact which is closed when the housing is closed If the state changes the LAN SecureAdapter will disconnect the network wire from SIP DoorStation to the internal network 2 Mode Loop resistance is measured reference value The network connection will be disconnected if the resistance changes about more than 1 5k Ohm So it is impossible to deactivate the sabotage loop by a short circuit A Resistor of 10k Ohm is recommended I The LAN SecureAdapter protects the intranet in case of sabotage at outdoor applications 20120713EB_HB_Baudisch SIP DoorStation EN doc 16 82 Eb 13 07 2012 Baudisch SIP DoorStation Version
34. P DoorStation sends a confirmation after successful verification and forwarding of the request The confirmation is only sent when the status messages were activated The data package has the status code 0x1E and as parameter is above defined remote controlled data package 1 1 sent back fills all 24 bytes of the parameter 20120713EB_HB_Baudisch SIP DoorStation EN doc 74 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 E Baudisch 6 6 Pin Strips on the Hardware Only specialists should use this feature View on the connectors on the PCB Boot Load Spare Store ie Save ele Several modes can be activated by putting a jumper on the pin header The strip for Store and Save are not mounted From Version 1 1 Description GE Pin 5 to 6 Load a Load factory default settings Pin 7 to 8 Spare a No function Store a Saves the current VoIP and Hardware settings as factory default Save Save DSP Mode 20120713EB_HB_Baudisch SIP DoorStation EN doc 75 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 6 7 IP Video Integration with Baudisch CP CAM 6 7 1 Video Display in the Web Browser The video data of the Baudisch CP CAM can be accessed directly over the IP network independent of a call or the SIP server That is a big advantage Without additional components the video qua color images can be viewed at several locations in the networ
35. P IP Adresses IP Adresse 192 168 1 175 Subnetzmaske 255 255 255 0 Add 20120713EB_HB_Baudisch SIP DoorStation EN doc Cancel 18 82 Baudisch Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 f enter the IP address 192 168 1 175 and sub net mask 255 255 255 0 Baudisch I An IP address from 192 168 1 1 to 192 168 1 254 can be chosen Only the IP address 192 168 1 200 is not to be used because it is used by the door module The address range is defined with these two entries which include the location of the PC laptop and its associated IP address g click on Add Advanced TCP IP Settings IP Settings DNS WINS Options IP addresses IP address Subnet mask 192 168 0 71 255 255 255 0 255 255 255 0 255 255 255 0 Edit Default gateways Gateway Metric 192 168 0 9 Automatic Automatic metric Interface metric E Li I now the entered IP address and subnet mask are shown in the table h click on OK Internet Protocol TCP IP Properties You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address 192 168 0 71 255 255 255 0 112 168 Di 59 Obtain DNS server address automatically Use the following DNS server addresses 192 16
36. PoE Connect the door module to the PoE switch Power over Ethernet Switch with a network cable at X1 see chapter 3 3 Connection option 2 switch without PoE Connect a 24VDC power supply 24VDC 1A fused to the OV and UB of the terminal X3 see chapter 3 3 Connect the door module to the switch without POE with a network cable at X1 see chapter 3 3 The description on how to connect the optional accessories follows in the following chapter 20120713EB_HB_Baudisch SIP DoorStation EN doc 25 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 3 3 2 Connecting the Optional Accessories Installation kit sabotage contact Art Nr 33 0215 How to connect The connector is wired as follows Connector at Description sabotage contact Closing contact connected to common contact if housing is closed Opening contact a connected to common contact if housing is closed 20120713EB_HB_Baudisch SIP DoorStation EN doc 26 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 E eg Baudisch LAN SecureAdapter Art Nr 33 0216 Connection Jumper sabotage loop 1 sabotage loop2 o OV_OUT Connector Number Description function X1 GND input 24V_IN input EE OUT a output ee II a output se ama loop 2 178 Sabotage loop 1 Please refer to the Baudisch LAN SecureAdapter manual 20120713E
37. SDN based transmission technologies The voice communication and image are converted into digital signals VoIP VoiceOverlP and are then transmitted over the IP network in a specific protocol such as SIP Session Initiation Protocol Also by using an IP camera the digital video image data is sent over the same network 1 4 1 SIP und H 323 Apart from SIP systems are also using the H 323 protocol This method can simplistically also be called ISDN over IP However it requires very powerful hardware and has several disadvantages related to firewalls and network integration The Baudisch SIP DoorStation solely supports the sustainable SIP protocol 1 4 2 Advantages of the SIP Protocol This creates substantial advantages especially in companies which already have IT networks and structured cabling Existing IT resources can be used there is no need for an additional cable network Where there is no cable connection intercoms can be operated over W LAN IP radio link This ideal intercom system provides a solution even in private homes where almost always LAN connections are found Other devices such as specific exchange or switchboard technology storage distributors or interface modules are also unnecessary 1 4 3 Transmission and Connection Types of Calls Direct connections Door intercom PoE switch IP phone For the simplest applications for example in a home The intercoms call the IP address of an IP phone dire
38. Settings Audio Frames per Tx Default 1 1 iLBC frame size 20ms 30ms Speex Rate 8 kbps z _Seve Reset Preferred language codec e PCMU G 711 u Law is the standard for digital communication in Europe A very good voice quality but requires also a very high data volume from approx 80 to 100 kbit s e PCMA G 711 A law is the standard for digital communication in North America and Japan Very good voice quality but requires also a very high data volume from approx 80 to 100 kbit s e Speex is for the voice transmission optimized and therefore very scalable But only the data to rate is scalable The standard setting of 8kbit s should be sufficient for understandable communication The loss of data packages makes hardly to no problem e iLBC Internet Low Bit rate Codec was especially designed for the voice transmission over IP networks It generates a data volume of approx 14 kbit s 20msec frame size or 16 kbit s 30msec frame size and is robust in comparison to the loss of data packages e G 726 32 Generates a data volume of approx 32 kbit s by moderate voice quality e GSM 6 10 originates from the mobile communications area It generates only a very low data volume by an acceptable quality The settings for iLBC frame size und Speex Rate are only to be adjusted by experienced system administrators 20120713EB_HB_Baudisch SIP DoorStation EN doc 35 82 Eb 13 07 2012 Baudisch SIP DoorStation
39. TERN_2 input input 5V input 5V SL EXTERN_3 input 4 TXNO PoE Tx PoE via phantom powering middi 48V and at middi x OV RXPO PoE Rx PoE via phantom powering middi OV and at middi x 48V RXNO PoE Rx PoE via phantom powering middi OV and at middi x 48V LJ 1 PE Protection Earth connect to avoid dangerous 2 Mind the maxi load of contacts REL1 and REL2 3 Keep UB 24VDC within specified parameters Connector 3 fused fp U 1 a ils 2 g ae 5 5 n Ca If H Please make sure the used wire to X3 X4 is not longer than 1 5m 20120713EB_HB_Baudisch SIP DoorStation EN doc 57 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei TXPO PoE Tx PoE via phantom powering din USE 48V and at middi x OV TXNO PoE PoE via phantom powering Una 48V and at middi x OV RXPO PoE Rx PoE via phantom powering E OV and at middi x 48V PoE via Spare Pair powering 48V POE PoE PoE via phantom powering Ae OV and at middi x 48V fo PoE via Spare Pair powering ON TTL Service Interface SCI Baudisch COM eem JTAG RESET 20120713EB_HB_Baudisch SIP DoorStation EN doc 58 82 Eb 13 07 2012 Baudisch SIP DoorStation 5 4 Visualization 5 4 1 LCD Display e g 192 168 1 200 Bootloader mode Rescue boot Display test Version 1 8 As of 13 07 2012 Baudisch Descripti
40. a SIP session is recognized as DTMF event and is transmitted as payload in a separate RTP data package Cause of error when dialing is not possible disconnection shortly after activation There can be different reasons when dialing is not possible The most common reasons are related to the configuration field SIP domain e field blank not allowed e field with FQDN a filled domain without a given DNS server e Typing error in the domain or in the IP address Solutions e Ifin doubt enter the IP address of the SIP server when working in a local network e setup DNS server correct the typing error With which system solutions is the Baudisch SIP DoorStation tested to date and software compatible You will find a list of compatibility on our homepage 20120713EB_HB_Baudisch SIP DoorStation EN doc 80 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 8 Costumer Service Updates The description where you found the latest firmware and how to perform the updates is mentioned in chapter 4 7 Updates Support using FAQ Answers to frequently asked questions are found in chapter 7 FAQ E mail support support stentofonbaudisch de 20120713EB_HB_Baudisch SIP DoorStation EN doc 81 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 9 Glossary SIP Session Initiation Protocol is a network protocol to dial to control and to end a
41. a specified UDP command is triggered via an external software Light camera The relay is activated by dialing at the intercom and during a call Failure The relay is activated when there is no failure It deactivates when there is no network connection only standard version no connection to the SIP server only when the registration at the server is activated and by a power outage Remote controlled No automatic function is assigned to the relay and it can therefore be remotely controlled without interaction via internal control operations per UDP Call signal By this function the relay is activated for the set duration via central call dialing This makes it possible to control a second ring or to inform a building management system of the dialing process Pulse duration Drop out delay of relay 1 door relay 2 light Depending on the assigned function the setting is either a pulse duration door opener or a drop out delay light camera There is an immediate switch by the failure notification function when a new condition is recognized By the remote control is the preset pulse duration relevant Door opening signaling The door opening signaling operates with the same principle as a blind traffic light A tone signal is heard as long as the door opener is pressed It can for example be useful by the application of a direct current voltage opener because there is no electro acoustics carried out Phonebook Timeout
42. audisch SIP DoorStation Version 1 8 As of 13 07 2012 E Baudisch 4 3 3 Switchboard and Basic Displays The central call number will be dialed if the call button is pushed without selecting a phone book entry i Baudisch SIP DoorStation Switchboard and basic displays Name Number DTMF Code Incoming Outgoing Relay Group ID NR 116 central call fis2 168 15 fi GIE GE GE Accept Announcement Off for None z d esse select a far phone book _Seve Reset n Calls of numbers entered in this menu will only accepted if they are not configured to reject in any other list Name Here you can define 3 fields of texts which are displayed one after another automatically The text in the upper field acts like the name in the phone book or like browsing through the entries This text must be valid do not leave it empty To avoid a line break use an underscore 4 3 4 Unknown Caller The Options Name DTMF code etc act like the entries in the Switchboard but are only effective for unknown callers Due to this there is no option for outgoing calls d 1 Baudisch SIP DoorStation Unknown caller Name DTMF Code Incoming Relay KR show number instead of name Unknown caller _Save _Reset Name In this field it is possible to enter any number It is shown on the display in case of a unknown number is calling Feel free to leave the field empty and activate the option Show number instead of name
43. communication session between two and more participants The protocol is specified in RFC 3261 SIP is a frequently used protocol in the IP phone communication http en wikipedia org wiki Session_Initiation_Protocol H 323 is a protocol in the H32X series which also includes the communication over public phone networks and ISDN http en wikipedia org wiki H323 PoE Power over Ethernet describes a method where network capable devices are supplied with energy over the 8 core Ethernet cable http en wikipedia org wiki Power_over_Ethernet Midspan By the midspan power supply a feeding device is placed between the switch and the PoE end device This way the switched feeder supplies the end device with the necessary PoE voltage using both unused pairs of core Endspan With this type of PoE supply the switch is able to directly deliver the supply of voltage to a PoE end device without midspan feeder The feeding takes place via the data lines 20120713EB_HB_Baudisch SIP DoorStation EN doc 82 82 Eb 13 07 2012
44. ctly By connecting several ring buttons every ring button can have a different call destination assigned Public SIP provider Door intercom and IP phone are switched free of charge via a public SIP provider internet access and at least one DSL connection required Transfers from SIP to the fixed and mobile phone network are offered on favorable terms This makes the door intercom a worldwide telephone Even switching functions e g the door opening can be carried out while on the road Local SIP server software This software can be run on any PC For example the 3CX SIP server software also available as freeware runs directly on a Windows server Alternatively Asterisk is frequently installed on a Linux PC IP phone systems Many phone system manufacturers offer devices with SIP features Our door intercoms can also be directly connected there A current compatibility list is available on request 20120713EB_HB_Baudisch SIP DoorStation EN doc 8 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 2 Product Description 2 1 General Information The Baudisch SIP DoorStation is a web compatible VoIP door intercom with easy to operate dial number selection by a LCD with integrated phone book with up to 115 entries and a integrated IP camera The device is the first choice if there are alternative subscribers along with a main intercom station You can add up to 100 entries
45. ddress In case the IP address was manually changed the web browser can possibly no longer show the page with the response In this case enter the new IP manually in the browser to get back to the starting page of the web interface Subnet mask The subnet mask informs the door module of the size of the sub net in which it is located Standard gateway A gateway is a transmission point between different nets I The settings for the DNS Domain Name Server can be set either manually or automatically via the DHCP Server e Automatically obtain the DNS server IP When this option is chosen the fields for the primary and secondary DNS are shown gray and the IP address is automatically obtained e Use the following address If this option is chosen the primary and secondary DNS must have been assigned addresses The settings for QoS Quality of Service are only to be adjusted by experienced system administrators Basically these settings serve to prioritize the data packages for the voice transmission compared to other network data communication 20120713EB_HB_Baudisch SIP DoorStation EN doc 34 82 Eb 13 07 2012 Baudisch SIP DoorStation Baudisch Version 1 8 As of 13 07 2012 4 4 2 Codec Settings H Baudisch SIP DoorStation Codec settings Codec favored Codec 1 Pemu in listed order codec 2 POMA Codec 3 Speex z Codec 4 iLBC 7 Codec 5 726 32 D Codec 6 GSM 6 10 D Network Codec
46. e no confirmation will be sent on a remote command 20120713EB_HB_Baudisch SIP DoorStation EN doc 46 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch SIP NOTIFY When a Baudisch CP CAM is connected to the SIP DoorStation the image of the corresponding CAM can be shown by calls to a Snom 820 VolP phone Therefore a separate file must be run which is located on the Baudisch CP CAM The path for the URL to the Snom XML file must be entered here 4 6 Configuration Camera For connection and configuration of the in the version Video integrated camera please refer to the manual Baudisch CP CAM 4 7 Updates Updates can be imported for the firmware the ring tone and for the announcement d D Baudisch SI Update Upload Firmware Cc Ring Tone Announcement Cc Factory S Factory P Update File Start Upload Reboot Warning Update process must NOT be interrupted Note An update process may take a few minutes Please do NOT turn off the power The following file types are given Firmware xxxx bin Firmware file for the intercom Ring tone xxxx dat Sound file see chapter 6 9 DTMF Code Example Announcement xxxx dat Sound file see chapter 6 9 DTMF Code Example Factory setting S Upload for setup data Factory setting P Upload from phone directory data 20120713EB_HB_Baudisch SIP DoorStation EN doc 47 82 Eb 13 07 2012 Baudisch SIP
47. e remote control for an IP address which indicates the status message to the recipient for the connection of a Snom 820 VoIP Phone 20120713EB_HB_Baudisch SIP DoorStation EN doc 39 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 E Baudisch 4 5 1 Audio To prevent feedback noise and reduce echoes the SIP DoorStation automatically detects if the remote intercom currently is active or not This way the direction of the speech is activated and the opposite direction toned downed It switches between the pair of values remote station speaking and remote station listening Appropriate settings can be entered here es Typical parameters are preset from the factory However they are very dependent of the installation environment and must be adjusted accordingly at the site of operation i Baudisch SIP DoorStation Precedence control Precedence switching threshold for Remote station speaking Il Falco Precedence switching time for Remote station speaking 10ms 40 Remote station speaking Microphone level 1 p Remote station speaking Speaker level K e allo Remote station listening Microphone level 1 papaj Remote station listening Speaker level 1 Fara Signalling Level of Ringtone incoming call 96 papa Level of signal tones to local speaker T i paba Level of signal tones to remote station paba Misc Mute time after DTMF detection tise foa
48. eactivated SNTP Server and Time zone The time zone for the system time and a server over which the current time is loaded can be entered here The time is set to the standard time GMT and responds accordingly without consideration of the summer and winter time To consider these the option adjust clock must be activated 4 5 Settings Hardware Audio Settings for the precedence control of the speaker and microphone levels by the connection with another intercom as well as the switch barrier and switch duration Signaling settings for the volume of the ring tone and the signal tones 20120713EB_HB_Baudisch SIP DoorStation EN doc 38 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch System Settings for the function and pulse duration of relay 1 and 2 the door opener signaling the ID announcement the extended port function and the keypad options Call Opt Settings for the call duration the dialing and the redial attempts for the request for acknowledgement via DTMF characters for the call buttons of the matrix module the central call button as well as the direct call button for the number of cycles of the chain calls Status Remote Settings to activate the status message and or the remote control 0f for the entry port for the remote control and the exit port for the status message for the code authentication which is required for the use of th
49. ed to identify the intercom This way the assignment is processed by an incoming call That means that the caller communicates the call enquiry as lt phone number gt sipdomain com or as lt user ID gt sipdomain com SIP authentication ID and SIP authentication PIN User name and password for the login at the SIP server Username This field is only for information purposes and has no special function For example the call number of the door module could be entered here to simplify the administration of the SIP accounts It would alleviate the assignment of the user data to the call numbers because mostly the user IDs are different than the call numbers 20120713EB_HB_Baudisch SIP DoorStation EN doc 36 82 Eb 13 07 2012 Baudisch SIP DoorStation Baudisch Version 1 8 As of 13 07 2012 4 4 4 Extended SIP Settings Baudisch SIP DoorStation Extended SIP settings Local SIP Port 5060 Standard 5060 Local RTP Port km Between 1024 and 65535 Default 6000 SIP Registration Timeout 50 in Seconds Default 60 Keep Alive Intervall fo In Seconds Default 20 System Send DTMF SPm gt Help DTMF Payload Type 101 Range 96 to 127 Default 101 6 726 32 Payload Type Mm Range 96 to 127 Default 111 iLBC Payload Type BB Range 96 to 127 Detaut 98 Speex Payload Type 10 Range 96 to 127 Detaut 110 ings Extended SIP Settings Support PRACK RFC3282 No C yes Required Pr
50. eege ia ii 54 5 2 1 Baudisch SIP DoorStation Standard i 54 5 2 2 Baudisch SIP DoorStation Videon 55 5 3 Howto Kee e dE 56 E ENEE E e E 59 GE N NG De iii aaa ae 59 5 4 2 EDS ea EE 60 5 4 3 Declaration of Conformity i 61 6 EE eege eege ee 62 6 1 AVR Firmware Update iii 62 6 2 EasvLanGonnectioni H iaia erica 66 6 2 1 General Information een a 66 6 2 2 Using an EasyLan Connection nenne 66 6 2 3 Baudisch EasyLan Field Bus Module and Functions nn 66 6 2 3 1 Controlling per PC or Embedded PC via an EasyLan PC Interface 66 6 2 3 2 The Connection to the ASB_321nSPS_4OutRelais i 67 6 2 4 Configuration Baudisch SIP DoorStation for EasyLan een 68 6 3 SpecialFUNcions iraniana iaia iii 68 6 3 1 Functions with the Configuration Parametere 68 6 3 1 1 Send Door Opening Code during a Call nssr nesn nesr nssnnssrnssrnssrnssne 68 6 312 e E e 68 6 3 1 3 Button Simulation i cane ae 68 6 3 1 4 Disconnect a Call after Remote Relay Operation 69 6 3 1 5 Activation of the DTMF Relay Selection i 69 6 3 2 Read or Write the Configuration Parameters ii 70 6 4 Status Messages illa eifel alii 73 64 1 Protocol anne aLaaa ira 73 20120713EB_HB_Baudisch SIP DoorStation EN doc 3 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Ba
51. emote site during the call Up to 4 digit codes can be entered Shorter codes must be left justified In case several identical characters are used consecutively a pause of approximately a second is required between each character in order for the code to be recognized Incoming Just like for any incoming call a decision has to be made on how to proceed The options are Not answer automatic answer automatic answer with announcement and signaling an answer via a ring button The additional option beep makes sure that the phone partners hear a signal tone during the audio connection Outgoing By outgoing calls is decided if a message is to be left by the recipient for example location of the intercom 20120713EB_HB_Baudisch SIP DoorStation EN doc 30 82 Eb 13 07 2012 Baudisch SIP DoorStation Relay Version 1 8 As of 13 07 2012 Baudisch Here is decided whether or not the call display relay is switched on during a call If the setting on is chosen the relay remains switched on from the beginning to the end of a call Group ID It is possible to assign a group of several call destinations with this setting When a call destination out of a group is called and not reached then all call destinations out of this group are called They are called one by one according to how they are listed in the phone book Other related settings are possible in chapter 4 5 3 Call Options at global call parameters and
52. emperature 20 to 50 C 20 C after 15 min time of operation 20120713EB_HB_Baudisch SIP DoorStation EN doc 52 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch Configuration operation and visualization Web server Integrated web server for configuration of all parameters and the internal phone book via LAN and web browser LCD LCD display Doublespaced with backlight 3 buttons for browsing and calling LEDs operation mode Baudisch SIP DoorStation 3 LEDs Miscellaneous RFC 2833 DTMF RFC2976 SIP Info Protocols SIP via 10 100 Mbit LAN IPv4 TCP RTP DHCP UDP http tftp VLAN IEEE 802 1pq Audio e Used Speaker RL 8Ohm 1W Typ Output power 1 36W at RL 80hm Typ Output power 2 22W at RL 40hm Typ Output power 2 45W at RL 30hm e Integrated microphone e Jitter Buffer Used audio codecs PCMU PCMA Speex iLBC G 726 32 GSM 6 10 Additional at SIP DoorStation Video Network switch integrated switch Baudisch SIP DoorStation Video e REALTEK RTL8305SC e Ethernet 10Base T und 100Base TX e Halfduplex fullduplex e Auto Negotiation Picture video Color picture 640x480 VGA digital detail zoom shift video picture MJPEG JPG compression rate adjustable display rotatable in 90 steps Night mode With the integrated infrared light it is possible to switch to night mode automatically The switching on threshold is adjustable 20120713EB_HB_Baudisch SIP DoorStatio
53. f the signaling tones which the person hears at the remote station DTMF confirmation confirmation acknowledgement door opener signaling and error tone Misc Mute time after DTMF detection The speaker at the door module is switched to mute mode as soon as the second DTMF digit is entered When the code is correctly entered the mute modus is immediately cancelled after the positive confirmation When an incorrect or an incomplete code is entered the mute modus is cancelled after the mute time 4 5 2 System i Baudisch SIP DoorStation System Audio System roa Relay 1 function Door opener x Call Opt Status E Pulse durationDrop out delay of Relay1 1secl foii Relay 2 function lahitam Sl Pulse duration Drop out delay of Relay 2 1sec p ka Door opener signalling Sound 1 Phonebook Timeout 41sec ppa Length of Announcement 1sec 4sec Backlight mode On x Extensionport Function EasyLan 4 800 bps 862 DHCP Retry Timeout 14sec Je 2 Save Reset 20120713EB_HB_Baudisch SIP DoorStation EN doc 41 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch Function of relay 1 relay 2 The existing relays on the module can be triggered in different ways to carry out different switching operations Door opener By this function the relay is triggered when the called person enters a DTMF code on a keypad which is listed in the phone directory or when
54. hernet SIP able terminal devices di Baudisch SIP Sprechstelle Only Baudisch SIP DoorStation IP54 Video or use of a separate camera The simultaneous use of these connections must be checked individually 20120713EB_HB_Baudisch SIP DoorStation EN doc 11 82 door opener relais Baudisch Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 2 3 Scope of Delivery m e O Description SIP DoorStation IP54 video SIP Sprechstelle IP54 Video Central call button 2 selection Direktruftaste 2 Blattertasten keys for destination illuminated beleuchtetes LCD Display CP CAM LCD display CP CAM Stromversorgung 24V oder PoE Power supply via PoE or 24VDC Schutzart IP54 Wandmontage x incl Assembly kit 4 screws 4 studs 4 clogging pads SIP DoorStation IP54 standard SIP Sprechstelle IP54 Standard Central call button 2 selection Direktruftaste 2 Bl ttertasten keys for destination beleuchtetes LCD Display illuminated LCD display Stromversorgung 24V oder PoE Power supply 24V or PoE Schutzart IP54 Wandmontage Protection class IP54 wall mount incl Assembly kit 4 screws 4 studs 4 clogging pads 20120713EB_HB_Baudisch SIP DoorStation EN doc 12 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch Optional Accessories tem number Description 33 1397 Baudisch
55. input signals and release 4 output signals e The inputs and outputs can be set or read via the EasyLan data bus as well as a RS232 terminal interface Supply voltage between 9 and 30V DC The inputs are electrically isolated by optocoupler and executed with a common minus potential point It is operated using a positive DC voltage between 9 and 30 V DC 16 inputs and 2 outputs are available on two 25 pin SUBD connectors male respectively The RS232 interface is designed with a 9 pin SUBD connector female which enables the connection of a PC with a 1 1 extension cable e The power supply as well as the data bus connection are connected via 4 pin screw type terminals Each device has 2 such terminals which are internally direct parallel switched This enables a simple linkage of several devices All inputs and outputs are visualized by LEDs e I ber die 32 Eing nge des Moduls k nnen Rufe auf und abgebaut werden 20120713EB_HB_Baudisch SIP DoorStation EN doc 67 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 6 2 4 Configuration Baudisch SIP DoorStation for EasyLan Start the configuration menu see chapter 4 2 Start of the Configuration Menu e Hardware settings System e Set the function expansion port to EasyLan 4 800 Bps 8E2 6 3 Special Functions Several Parameter in EEPROM Register can be read and written via UDP Changes can activate special function
56. is disconnected after the expiration of this term Timeout connection attempt Decides the time of how long is waited for a call to be made This parameter can also be set by a SIP provider and a SIP server respectively The dial attempt is disconnected when there is no answer Redial attempts Number of redial attempts until the dialing process is disconnected A redial attempt takes place after the preset delay time when the remote station is busy Delay between redial attempts Delay between dial attempts There is a delay between redial attempts only by a chain call A dial attempt follows immediately with a phone number change Wait for acknowledge This function can be set when an explicit acknowledgement of a call acceptance is desired The called person must confirm the acceptance by pressing a key Otherwise the call is discontinued after 10 seconds and a new number can be dialed DTMF character for acknowledgement Choice of key with which the called person should confirm the call acceptance 20120713EB_HB_Baudisch SIP DoorStation EN doc 43 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch Call chain option In case the entered numbers were divided into groups group ID the numbers within a group are called in sequence until a connection occurs a call acceptance acknowledgement is given or the entered call chain cycle is run through The order in which the entries in the phone direct
57. k also simultaneously via the web browser Only the execution of a Java plug ins is free A protected access with a password protects as needed the camera images against unauthorized viewing If the user network possesses an appropriately configured router is a global access of the camera images possible Camera CP CAM Default 6 7 2 Baudisch SIP VideoClient i Alternatively to the video images in a web browser this software allows the automatic display pop up of the door video images on the screen The called PC workstation displays immediately the image with the applicable Baudisch IP camera this saves the user the manual start of the display and the manual selection of a camera The door opens per mouse click with the pop up button In the same simple manner it is possible to save individual picture images by clicking or automatically by the door opening as JPG directly on the hard drive Item number 36 0204 20120713EB_HB_Baudisch SIP DoorStation EN doc 76 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 6 7 3 Snom IP Telephone with TFT Display With the desktop telephone snom 820 the video image of the CP CAM is directly shown on the phone display The image display of the desired camera can always be turned on using the speed dial buttons on the phone With a suitable function of the SIP server or a direct configuration without SIP server this
58. n EN doc 53 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 E Baudisch 5 2 Technical Drawings 5 2 1 Baudisch SIP DoorStation Standard 34 80 23 20 20 50 20120713EB_HB_Baudisch SIP DoorStation EN doc 54 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 5 2 2 Baudisch SIP DoorStation Video 20120713EB_HB_Baudisch SIP DoorStation EN doc 55 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 5 3 Howto Connect The Baudisch SIP DoorStation is in no case to be operated or charged with voltages of 230VAC If this is not followed possible lack of grounding can destroy the module to the point where voltage is applied to the housing which causes danger to life X12 socket board for Jumper X13 X8 X9 Switch T2 a A ala 2202929022929 X1 X2 X3 X4 20120713EB_HB_Baudisch SIP DoorStation EN doc 56 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei EH Baudisch situations Description Protection Earth External power supply 24VDC 1A Relay 1 closing contact Isolated contacts max load 24V 1A Relay 2 closing contact Isolated contacts max load 24V 1A EXTERN_1 input EXTERN_4 input Protection Earth TXPO PoE Tx PoE via phantom powering middi 48V and at middi x OV input 5V EX
59. nction Mode for loading factory settings is started or entering the save mode Alternately flashing Device is in save mode flashing Factory settings loaded saved Jumper can be removed flashing Kaff Error during loading saving of the factory settings or several jumpers plugged 20120713EB_HB_Baudisch SIP DoorStation EN doc 60 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 5 4 3 Declaration of Conformity EG Konformitatserklarung f r Ger te nach der EG Richtlinien 2004 108 EG EMV Richtlinie Das Gerat Baudisch SIP Sprechstelle Standard und Baudisch SIP Sprechstelle Video stimmt mit den Anforderungen der EG Richtlinie 2004 108 EG EMV Richtlinie in alleiniger Verantwortung von Firma Baudisch Electronic GmbH Im Gewerbegebiet 5 7 73116 Waschenbeuren berein Folgende harmonisierte Normen sind angewandt EN 61000 6 2 2006 3 mit den darin aufgef hrten Grundnormen St rfestigkeit Industriebereich EN 61000 4 2 2009 12 EN 61000 4 3 2008 6 EN 61000 4 4 2005 7 EN 61000 4 6 2009 12 EN 61000 6 3 2007 9 mit den darin aufgef hrten Grundnormen St raussendung Wohnbereich Gesch fts und Gewerbebereich sowie Kleinbe triebe EN 55011 2007 11 EN 55022 2008 5 W schenbeuren den 23 02 2009 Peter Baudisch Gesch ftsf hrer ar 20120713EB_HB_Baudisch SIP DoorStation EN doc 61 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 20
60. ommended Status on Remote control on 20120713EB_HB_Baudisch SIP DoorStation EN doc 62 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 E Baudisch Status Fernsteuerung Authentifizierungscode 0123456789 fizz Status IP Adresse Broadcast 255 255 255 255 Lee 255 255 255 Fernsteuerung Statusport Senden 1025 65534 be Fernsteuerport Empfangen 1025 65534 bas Status aus E Fernsteuerung Aus m SIP NOTIFY URL zur Snom XML Datei ZB 192 168 1 x snom cai C4 3 Save 4 Launch SIP Remote Control e Open the file to execute SIPControl exe on a PC in your network The file was included as an attachment in our e mail you received The following screen is shown 20120713EB_HB_Baudisch SIP DoorStation EN doc 63 82 Eb 13 07 2012 Baudisch SIP DoorStation E Baudisch SIP Remote Control Sendedaten Empfangen Absender IP Status Parameter Bcc seg Alle Nachrichten anzeigen Baudisch Roe Version 1 8 As of 13 07 2012 Einstellungen Senden Zieladresse 192 168 1 200 m Releais 10s Eingangsport e112 Relais 4 Relais 2 8113 Open Ausgangsport D SES SS Unlock ausschalten X Code DTMF Zentralruf 1 ei ei wi4 e Program beenden m Remote Senden Jo zb zo d n CMD senden A ln Sp jo 5 Make the following settings in the
61. on The current IP address is displayed in stand by mode as long as the device is not registered to the SIP server By putting the jumper see chapter to position Mac the current IP address and the MAC address of the device is shown This is helpful to find out the assigned IP address in case of DHCP use The SIP DoorStation is in Bootloader mode Maybe there occurs an update There is an error during checking firmware consistency The SIP DoorStation is not running and is waiting for an update command for the AVR Firmware It is possible to test the LCD To do so set the jumper see chapter to position Boot or on older hardware to LCD test As a result of that all pixels of the display are activated 20120713EB_HB_Baudisch SIP DoorStation EN doc 59 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 5 4 2 LEDs The SIP DoorStation visualizes the current state on 3 green LEDs LED1 is illuminated if supply voltage is available LED2 and LED3 show the following modes Operating mode LED2 and LED3 Description If the device is powered it is in stand by mode and it is connected to the SIP server The device is powered and in stand by mode the SIP server connection has not been established until now Visualizes the state of the call or the dial up state to an external subscriber There is no visualization for an incoming call Transition state special fu
62. ory are set decides the sequence of a chain call The index in the following table shows the sequence Configuration menu a phone book 1 1 Example Index contact 2 2 11 11 and 113 73 are assigned to a group ID When a contact is called within this group ID and not reached then the next contact is called and so on When the cycle is run through then the number of call chain cycles decides whether to discontinue or run through the given cycles 2 13 Call Chain Cycles Here you can adjust how many times the call chain must be repeated I The function of the call chain is illustrated in the following flow chart 20120713EB_HB_Baudisch SIP DoorStation EN doc 44 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei lt gt gt Ye s Dial number Baudisch Connection state and acknowledgment Next Call Number No No Redial Nein Last number of the group Yes Yes Break i Ce o Another cycle 20120713EB_HB_Baudisch SIP DoorStation EN doc 45 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Baudisch 4 5 4 Status Remote d E Baudisch SIP DoorStation Status Remote on Code for remote authentication 0123456789 baa Status Remote IP Address Broadcast 255 255 255 255 255 255 255 255 Status Port Transmit 1025 65534 18112 Remote Port Receive 1025 65534 18113 Status on Remote
63. ose firmware File to be transferred enter the path where the file xxx bin from us is located Start the transfer and wait until the automatic reset of the module which is performed after an update is completed lt 2 min You have successfully updated the firmware 20120713EB_HB_Baudisch SIP DoorStation EN doc 48 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 4 8 Reset to Factory Settings The device can be reset to factory settings when the setting of the IP address or the access password is unknown I When loading the factory settings all VoIP and hardware settings are reset The entries in the phone directory are not affected The preset network settings are IP address 192 168 1 200 Sub net mask 255 255 255 0 Password 1234 4 8 1 Reset to Factory Settings Version lt 1 0 Preparation For a factory default setting there must be a terminal connected to the service interface of the SIP DoorStation Open the SIP DoorStation see chapter 3 2 1 Opening the SIP DoorStation and connect a PC with a serial interface and a terminal application e g HyperTerminal In the following you can see an example of the HyperTerminal settings si DE Port Settings ConnectTo Settings m Function arrow and ctrl keys act as Terminal keys C Windows keys Bits per second 13200 x m Backspace key sends Ze Dahl Del Ctri H Space Ctrl H Data bits
64. oxy Features ian NAT Traversal Disabled NAT IP boso STUN Server Be IP or URI STUN Server Port p Default 3478 _Seve Reset Local SIP Port The SIP protocol which is responsible for the administration of the SIP connections is processed here via this specified port Local RTP Port The real time data transmission of the audio data is processed here via this specified port SIP Registration Timeout This setting indicates in which interval the registration by the SIP server is renewed Keep Alive Interval Indicates in which intervals an empty RTP data package should be sent to the SIP server in order for the RTP port to remain open due to a NAT firewall and alternatively a router Send DTMF Here is the method chosen over which the DTMF signaling is processed e Inband Audio DTMF tones are transferred as audio data e SIP info DTMF digits are transferred via the SIP protocol e RFC2833 DTMF digits are transferred via the RTP protocol Data type to be used DTMF G 726 32 ILBC Speex The data type to be used should be left on its standard setting There is no special benefit for the user here Support PRACK RFC3262 If this setting is activated specific signaling in the SIP protocol is secured Required Proxy features Characteristics which the proxy server must handle 20120713EB_HB_Baudisch SIP DoorStation EN doc 37 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012
65. remote control can be used to operate the relays 1 and 2 and the camera lOs 1 and 2 Further there are several more functions 6 5 1 Protocol A UDP data package is structured as follows lt ID gt lt Sender IP gt lt Seq No gt lt Output No gt lt Duration gt lt Password gt lt Proof total gt ID Identification of the protocol BSREM 5 characters ASCII Sender IP Contains the IP address of the sender as a string of hex digits 192 168 0 2 would be COA80002 Seq No Sequence number Serves to identify the package when a number of packages is sent This way double received packages can also be recognized The sequence number is represented as hexadecimal with two digits in the range 0 to 255 00 FF Output No Output number Number of the controlled output Allowed values are 1 to 4 The number consists of only one hex digit 1 Door opener relay 2 Light relay be aware of special function in the web interface 3 Camera IO 1 4 Camera IO 2 Duration Is encoded as two digit hex string 0 off 1 on permanent 2 255 duration in seconds Password Code of authentication Is switched only in accordance with the specified authentication code in the configuration menu Unused spaces of the password must be sent as F The authentication code always consists of 4 digits DTMF characters 0123456789 and F Proof total The proof total is formed as in the status messages I The SI
66. resses l enter the IP address 192 168 1 175 and sub net mask 255 255 255 0 Leave the rest of the fields blank I Choose an IP address from 192 168 1 1 to 192 168 1 254 with the exception of IP address 192 168 1 200 This IP address is being used by the door module 20120713EB_HB_Baudisch SIP DoorStation EN doc 20 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch m click on OK 4 Local Area Connection Properties General Authentication Advanced Connect using E Intel R PRO 100 Network Connectio This connection uses the following items M S Client for Microsoft Networks E File and Printer Sharing for Microsoft Networks 1 005 Packet Scheduler Internet Protocol TCP IP Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks I Show icon in notification area when connected Lo Notify me when this connection has limited or no connectivity n click on OK LI I The address range is defined with these two entries which include the location of the PC laptop and its associated IP address 20120713EB_HB_Baudisch SIP DoorStation EN doc 21 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of Connect 13 07 2012 a Baudisch network cable RJ45 24VDC N Pi as SIP Sprechstelle Video network cable RJ
67. rovides communication across diverse interconnected networks Show icon in notification area when connected Notify me when this connection has limited or no connectivity 20120713EB_HB_Baudisch SIP DoorStation EN doc 17 82 Eb 13 07 2012 Baudisch SIP DoorStation b Choose Internet Protocol TCP IP and click on Properties Internet Protocol TCP IP Properties Version 1 8 As of 13 07 2012 You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate P settings Obtain an IP address automatically Use the following IP address Obtain DNS server address automatically Use the following DNS server addresses 192 168 O 71 255 255 255 0 192 168 U 2 3 192 168 0 9 c when the field Obtain an IP address automatically is activated then skip the following pages to k d when the Use the following IP address and Use the following DNS server addresses are activated then do not change the values and click on Advanced Advanced TCP IP Settings IP Settings DNS WINS Options IP addresses IP address Subnet mask 192 168 0 71 255 255 255 0 192 168 1 71 255 255 255 0 L Default gateways i TERI 7 192 168 0 9 Automatic M Automatic metric Interface metric e click on Add by the IP addresses TC
68. s which are not accessible by the web interface 6 3 1 Functions with the Configuration Parameters 6 3 1 1 Send Door Opening Code during a Call Parameter SendDoorEnable Address 0x0603 1539d When this parameter is set to a value other than 0 a DTMF code from the phone directory can be sent to the remote station during a call by pressing the UP button twice As code is either the code of the called person sent or in case the call was made from the remote station the code of the identified participant or the code of the unknown caller 6 3 1 2 Call Logic Parameter CallAbortOptions Address 0x0602 1538d Value Function 0 Ending the dialing process and ending a call via any button possible 1 Ending the dialing process and ending a call via any button blocked 2 Ending the dialing process and ending a call via any other button than the one used to dial possible 3 Ending the dialing process and ending a call via any other button than the one used to dial possible as well as the selection of a new number 4 255 Works the same as for 0 6 3 1 3 Button Simulation je The activation of the following option of active simulation intervenes with the internal functional logic making normal operation no longer possible H This option should therefore only be used by specialized persons Parameter TestOptions Address 0xFF1 4081d Bit 0 1 a Activation of the call button simulation for long term or load tests It simula
69. s for dimensions 3 2 3 Cable Connection Put in the wires through the opening and connected as shown in chapter 3 3 I To lead in the wires it is recommended to remove the cover in the housing mas The wires are designed to be entered from the bottom to the top so no rain water can reach the inside of the housing Also there is a additional rubber seal 20120713EB_HB_Baudisch SIP DoorStation EN doc 23 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch I Density IP54 according to DIN EN 60529 is only given if the SIP DoorStation is mounted at a Siedle Vario housing or a plane surface covering the back of the SIP DoorStation Closing the DoorStation To close the device put the front part of the housing from the top to the rear part and use the two screws to fix in at the bottom of the housing I Make sure the front and rear part are well engaged 20120713EB_HB_Baudisch SIP DoorStation EN doc 24 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Baudisch 3 3 Connection 3 3 1 Baudisch SIP DoorStation Connection First pre configure then assemble see chapter 3 1 Preconfiguration Ethernet LAN A di Netzwerkkabel RJ45 A santo emp EI gt a gt oder Ethernet LAN ov Netzteil ve 7 Netzwerkkabel RJ45 u th 24V DC 24V gs A P eegen N D7 F A Switch ohne PoE D Connection option 1 switch with
70. sauaneeeeeeeeeeees 23 3 3 Connection 25 3 3 1 Baudisch SIP DoorStation Conpechon 25 3 3 2 Connecting the Optional ACcessorles i 26 4 Use and Configuration i 29 4 1 Starting Requirements wisest ee elek 29 4 2 Start of the Configuration Men 29 4 3 Phone BooKi aa dla ila 30 4 3 1 Phone Book Browse Mode nn 30 4 3 2 Direct Gall Keys 31 4 3 3 Switchboard and Basic Dieplavs i 32 4 3 4 Unknown Caller 32 4 4 Settings VolP siaus mgen aasan ar aaaea dein ia 33 4 41 Network een 33 4 4 2 Codec Settings neaei aiina EERE ENA AAEE ANETA EAEE AEE ET 35 4 4 3 SIP e incassi alia 36 4 4 4 Extended SIP Gemgs i 37 E EE 38 20120713EB_HB_Baudisch SIP DoorStation EN doc 2 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 4 5 Settings Hardware 38 RE E ee EE A0 A52 SyStEM EE 41 4 5 3 Gall Options nia ai 43 4 5 4 Status Hemote crisiiisnii oori auannaaeaa aedenaia aa ai anaa iaaa E aaia iaaaE 46 4 6 Configuration Camera nn 47 e EE EE 47 45 1 FIMWAle ira 48 4 8 Reset to Factory Settings 49 4 8 1 Reset to Factory Settings Version lt 1 0 49 4 8 2 Hardware Reset higher than VD 51 4 8 3 Reset Hardware 1 0 1 1 with Firmware V2 4 V4 1 i 51 5 Product Details ee einen hein peeks 52 5 1 Temra Dale tege ege eebe dee eege Ee eebe 52 5 2 Techical D tewlpgg Sege steet eed eet
71. sition Store Fa 5 Remove the jumper from position Spare and set to Load Fa Now the factory settings get loaded and the SIP DoorStation reboots Afterwards the display shows the stand by mode date time and System offline 6 Set the jumper back to position Spare and keep the arrow down button pushed until you can hear a sound After that happened the device will reboot 4 8 3 Reset Hardware 1 0 1 1 with Firmware V2 4 V4 1 1 Turn off the power supply 2 Set the jumper from position Spare to Load Fa see chapter 6 6 Pin Strips on the Hardware 3 Turn on the power supply PoE Endpan or connection terminal 4 Now there will start a automatically sequence Acknowledgement sound and LEDs red yellow are illuminated LCD output Defaults loaded only the red LED is illuminated LCD output Remove Jumper yellow LED is flashing 5 Remove the jumper and set it to Spare 6 If the jumper is removed the device reboots 7 You can also power off the device before removing the jumper yellow LED is flashing I If there is a unique sound and a fast flashing red LED you have pushed the switch S3 too early Please repeat the process If there is a regular sound and the red LED flashes every second there are several jumpers set or there is a short circuit at the jumper pin headers 20120713EB_HB_Baudisch SIP DoorStation EN doc 51 82 Eb 13 07 2012 Baudisch S
72. stream for an announcement may not be longer than 12 seconds and for a ring tone the maximum length is 22 seconds To convert the audio stream do the following 1 The tool mkSipSnd exe and the audio stream must be saved in a shared folder 2 Start the command line lt Start gt lt Execute gt cmd lt Return gt 3 Enter the path in the command line where audio stream and tool are saved 4 Enter the following command in the command line and confirm it with return mkSipSnd lt Name_Audiostream gt wav lt Name Audiostream gt dat Example mkSipSnd Announcement wav Announcement dat 5 A Dat file should be added in the folder where tool and audio stream are saved The Dat file can be loaded as ring tone or announcement via the update function of the door module see chapter 5 6 20120713EB_HB_Baudisch SIP DoorStation EN doc 79 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch 7 FAQ Which methods of DTMF transmission can be used There are 3 ways of transmission 1 Inband audio method over RTP A DTMF tone is created by pressing a button and coded via the set audio codec and then transmitted as payload voice data in the RTP package 2 SIP INFO method over SIP RFC2976 The information that a button pressed during a SIP session is transmitted as info message in the SIP data package 3 DTMF event method over RTP RFC2833 The information that a button pressed during
73. tes a keystroke according to the following parameters With the delivery is bit 0 0 deactivated The remaining 7 bits are not used Parameter SwitchPattern Address 0xFF2 4082d Bit pattern with which the buttons are set to be simulated Bit 0 SW_EXT1 Bit 1 SW_EXT2 20120713EB_HB_Baudisch SIP DoorStation EN doc 68 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 E Baudisch Bit 2 SW_EXT3 Bit 3 SW_EXT4 Bit 4 UP Bit 5 DOWN Bit 6 OK Bit 7 no function e I Not all combinations can be used because the buttons UP DOWN and OK only individually make sense and the other 4 buttons only as a bit combination If all bits are set to 0 is no button pressed The value of the following 3 parameters must be between 1 and 255 Parameter SwitchOnTime Address 0xFF3 4083d Time which should fit the bit pattern The time is a Value x SwitchGranularity x 50ms Parameter SwitchPauseTime Address 0xFF4 4084d Time expected between the strokes The time is a Value x SwitchGranularity x 50ms Parameter SwitchGranularity Address 0xFF5 4085d Unit of time for SwitchOnTime and SwitchPauseTime 6 3 1 4 Disconnect a Call after Remote Relay Operation Parameter RemoteCancelCall Address 0x0604 1540d Bit 0 ending the dialing process Bit 1 disconnect a call Bit 2 always execute the function at remote relay 1 Bit 3 always execute the function at remote relay 2
74. udisch E Ee EE 73 6 5 Remote Contoh geesde dee deed 74 6 5 1 Protocol isso ean ei einen al 74 6 6 Pin Strips on the Hardware 75 6 7 IP Video Integration with Baudisch CP CAM 76 6 7 1 Video Display in the Web Browser i 76 6 7 2 Baudisch SIP VideoClient iii 76 6 7 3 Snom IP Telephone with TFT Display ii 77 6 8 Guide for Audio Settings 20 2 cece cee i 78 GR DTMF Code Examples enseia a a g Ze alora 78 6 10 Create Ring Tones and Announcement Messages 79 7 FAQ aaa aaa 80 8 eu EN 9 Glossary csf illa elica ale 82 20120713EB_HB_Baudisch SIP DoorStation EN doc 4 82 Eb 13 07 2012 Baudisch SIP DoorStation 1 General Information 1 1 A 0e Symbols Warning of dangerous electrical voltage Baudisch Version 1 8 As of 13 07 2012 This symbol points out important references which must be followed to avoid injuries as well as damages and malfunctions of the product This symbol points out helpful references Software History DSP Version AVR Lib Description Function Expansion API Version 26 06 2012 V7 7 056000 V3 3 V4 5 26 04 2012 V7 7 056000 V3 1 V4 3 03 03 2012 V7 5 056000 V3 1 V4 3 31 01 2012 V7 4 056000 V3 0 V4 2 20120713EB HB Baudisch SIP DoorStation EN doo sun 807 2012 HB_Baudisch SIP DoorStation EN doc 5 82 e Bug fix TM Plus Volume control for signal tones did not work correctl
75. um housing Indicator via LCD display There a 3 buttons for operating selection of a subscriber and call 20120713EB_HB_Baudisch SIP DoorStation EN doc 9 82 Eb 13 07 2012 Baudisch SIP DoorStation Version 1 8 As of 13 07 2012 Ei Baudisch Additional Features Version Video e 2 5mm long distance object lens with horizontal angular field of 83 e 6 integrated IR LEDs guarantee a well illuminated area at night Integrated switch with PoE input So the connection of the camera and the DoorStation is possible via one network cable The colored videos can be displayed in common web browsers also simultaneously at several PCs at the same time Support of the pop up software Baudisch SIP VideoClient to realize automatically displayed videos in case of a incoming call e Simple configuration of the camera via integrated web server L I For special installation situations and OEM solutions there are the electronic devices integrated in the SIP DoorStation available separately This allows OEM costumers to design their own specific housings 20120713EB_HB_Baudisch SIP DoorStation EN doc 10 82 Eb 13 07 2012 Baudisch SIP DoorStation 2 2 Settings VoIP Version 1 8 As of 13 07 2012 SIP telephone system Display video image Internet Fi Gerda Hiibsch d E A FM Annette Nett merce Baudisch Tastenmodul Remote Control Relais Et
76. ush on the key symbol button e Correction of parameter compensation DSP gt AVR in lib e Offset code for 2 relay DTMF amp Keypad added e DTMF call potion via keypad independent to configuration e Blocking of code entry via key pad and or via DTMF through UDP command e Bug fix No negative acknowledgment in case of pushed button if device between state STOP and IDLE e Tone signal for button refuse conformed e Relays selectable via key pad 99x e Alternative numbering of speed dialing keys at the keypad e Option for blocking some key pad functions e Adjustable block time between call break and another call e Style sheets in web interface customized e Bug fix periodic transaction of user name via UDP e New API Reorganization of DSP Code e DSP_COM extension e Remote audio parameter calculation amended e Extension of relay options e Line busy tone deleted e Correction Endless loop at chain call if triggered by central call e New function Call cancellation via UDP door opener e New function Selection of door opener relay at DTMF e LCD functions customized to new model Old LCD is still working e Phone book Javascript optimized e Customization of DTMF interpretation new Inband interpretation Display texts work also if registration is off e SIP Stack for systems ignoring Video NOTIFY customized e Content Len in SIP NOTIFY modified e In field number
77. y e TM Plus Audio volume changes can now be done via DTMF SIP Control same way as with TM Maxi Eco Added remote call handling e Added IO Status message Bug fix Device stops transmitting registrations in some cases e Web interface java elements customized due to problems with saving with IE8 and IE9 e Lock of door opener customized Reset of the tries counter at correct code entry Time for counter of tries reduced to 2 min Max number of failures increased to 4 e Customization Auto test works in devices that scan buttons in firmware not in lib e Bug fixes Broadcast in local subnet fixed before only 255 255 255 255 e DHCP timeout adjustable due to problems with Rapid Spanning Tree e Alternative call tone output for keypad available e Option for Keypad Only 4 digit codes allowed DTMF may use less than 4 digits e Keypad Neaative acknowledament in state Eb 13 07 2012 Baudisch SIP DoorStation 14 10 2011 V7 3 048000 V2 7 V3 8 04 10 2011 V7 3 048000 V2 6 V3 7 01 07 2010 V6 9 047001 V5 9 V3 0 01 06 2010 V6 8 047001 30 04 2010 V6 7 044001 24 02 2010 V6 6 044001 20120713EB HB Baudiech SIP Doer iston Ee oun Eiaam ans HB_Baudisch SIP DoorStation EN doc V5 9 V3 0 V5 9 V3 0 V5 8 V2 9 6 82 Version 1 8 As of 13 07 2012 Ei Baudisch CLOSE KEY_CLEAR added e Keypad Stop of code entry with a further p